Loading...
HomeMy WebLinkAboutAPPROVED Wind Load compliance-Lot 1 Custom Model_L1� LUCE IFR 1� Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1577 Certification for Design Load Compliance Th Edition Project Name: Tarpon Flats Lot 1 Project Address: 3937 Shore Side Drive Ft. Pierce, FL. Permit #: INSTRUCTIONS FOR USE: Occupancy Type: R-3 Construction Type: V-B • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2020 Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II 111 IV Exposure Category: B C X D 4. Design Wind Velocity 170 mph ASD LRFD End Zone Width: ft 5. Mean Roof Height 15.15' ft Roof Pitch: 6 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: Zone 4: -38.56 Zone 5: -45.05 Garage: +32.21 / -38.90 An Rnnfc Maximum +/- pressures: + psf - psf Or define individual zones on the plans 7. Design Loads: Floor: 138 PSF Roof-Dead:35 PSF Roof-Live:20 Balcony+/- PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? Yes Not Applicable Please Explain: 9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the current Florida Building Code as adopted. ABUG, /, � �P.•'L�GENS '•.qs Print Name Cert # & Co. Cert ofAuthorization * 07 0 S. Company Name & Address `' F�ORIDP.•'' �\�� Digitally signed by %�ONA` Farid Farid Abugattas ��\\\ r1 /\bu allaSDate:1011.08.20 g 17:41:21-05'00'