HomeMy WebLinkAboutCarlisle WIP GRIP PANEMO I etc.
Certificate of Authoriratfon #32495
3S3 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT
Carlisle Coatings & Waterproofing Evaluation Report C39180.12.1,1-Rfi
900 Hensley Lane ELMS-1110
Wylie, TX 75098 Date of Issuance:12/09/2011
(717) 245-7000 Revision 6: 08/13/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have evaluated for
compliance with the 71" Edition (2020) Florida Building Code sections noted herein.
I I I RIPTION: CW Roof UndE r ayments ■ . ► i❑ r �`
BELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
AovERTI5EMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOI etc, Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
IN5PECTiON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
Robert J.M. Nieminen, P.E.
•' pfix'
The facsimile seal a ppearing was autharix®d
Florida Registration No, 59166, Florido DCA ANE1983
�+u.,a, ; ; • ``' by Robert Nieminen, P.E. an 09/13/2020
This does not serve as an electronically signed document.
CERTIFICATION OF IsDEPENDENCE:
I. NEM0 ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or
distributing products it evaluates.
2. N E M 0 ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert N€eminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. !Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
G 2019 NEMO ETC, LLC
ROOFING COMPONENT EVALUATION:
ONEMOletc.
•
Product Category: Roofing
Sub -Category: Underlayment
Compliance statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing, have
demonstrated compliance with the following sections of the 7" Edition (2020) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
2. STANDARDS:
Section
Pro a
standard
Year
1507.1.1, 1507.2.4, 1507.2.9.2 / Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRt, Sixth Edition
2018
TAS 110
3.
Accelerated Weathering
ASTM D4798
2011
REFERENCES:
Entity
Fac_mination
Reference
Date
ERD (TST6049)
ASTM D1970 (TX)
C41280.10.12
10/05/2012
MT€(TST2508)
ASTM ❑1970(PA)
PX02MOA
01/17/2011
MTi (TST2508)
ASTM D1970 (PA)
PX13MOB
01/18/2011
ICC-E5 (EVL2396)
2018 IBC/IRC Compliance
ESR-1556
02/01/2020
ICC-ES (EVL2396)
2018 IBC/IRC Compliance
ESR-2206
06/01/2020
NEMO (T5T6049)
FRSA/TRI (09-18) (PA&TX)
4S-CRL-18-004.12.18-1
12/17/2019
NEMO (TST6049)
ASTM D1970 (adhesion) (TX)
4S-CRL-1MD4
01/21/2019
NEMO (TST6049)
ASTM D1970 & D4798 (PA)
4j-CRL-I9-SSUDL-03.A
05/28/2019
NEMO (TST6049)
ASTM D1970 (PA)
4j-CRL-19-S5UDL-02.A
06/03/2019
NEMO (TST6049)
ASTM D1970 & FRSA/TRI (09-18) (TX)
4S-CRL-1M04.06.19.A
06/12/2019
UL, I.I.C. (QUA9625)
Quality Control
TGDY.R18678 Listing
10/18/2010
UL, LLC. (QUA9625)
Quality Control
Service Confirmation
04/13/2017
4.1
4.2
4.3
4.4
4.5
4.6
Product
Material Standard
Plant(s)
Description
WIP 100
ASTM D1970
Carlisle, PA
self -adhering, fiberglass reinforced, granule
surfaced, rubberized asphalt roof underlayment
WIP 10OSG
ASTM D1970
Carlisle, PA
self -adhering, fiberglass reinforced, granule
surfaced, rubberized asphalt roof underlayment
WIP 250HT
ASTM D1970 and
Carlisle, PA
self -adhering, fiberglass reinforced, film
FRSA/TRI (09-18)
surfaced, rubberized asphalt roof underlayment
WIP 300HT
ASTM D1970 and
Terrell, TX
self -adhering, coated-polyolefin-composite film
FRSA/TRJ (09-18)
surfaced, rubberized asphalt roof underlayment
WIP 40GHT
ASTM D1970 and
Terrell, TX
self -adhering, polypropylene film surfaced,
FRSA/TRl (09-18)
rubberized asphalt roof underlayment
W1P GR€P
ASTM D1970
Carlisle, PA
self -adhering, fiberglass reinforced, film -
surfaced, rubberized asphalt roof underlayment
NEMO ETC, LLC Evaluation Report C39120.12-11-R7
CrrWarteQlAudmUatfm#JZ4M 7' EDITION (2020) FBC NON-HVHZ EVALUATION FL4785•RID
Carlisle Coatings & Waterproofing; (717)1"-7000 Revision 7; oa/13/2020
Page 2 of 5
ONEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -Dade
Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Referto FBC 2603 for requirements and €imitations
concerning
the use of foam plastic insulation.
5.5 CCW Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction (AHJ) for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5,6 Allowable Roof Covers;
TABLE 1: ROOF COVER OPTIONS
Asphalt Clay and Concrete Tile Metal Slate or wood
Lirtderlayment Shingles {I507.3) slate -Type
Ph
(1507� Mechanical Adhesive- Panels shingles Shingles Shingles shakes
Shingles
Attach set (1507A) (1507.5) (1507.7) (1507-8) (15079)
11507.I7)
Yes Yes
Yes
WIP no Yes No No No No No (joint strips, OofntVAps,
I]nlntS*vs,
I507,1,1.31 1507,1,1,3)
1507.1.1.11
R905,1.1.3} R905.1.1.31
R905.1.1,1J
Yes Yes
Yes
WIP 1005G Yes No No No No No Iinint strips, IloRn strips,
holm strips,
1507,1,1.31 1507.1,1.31
1507.1.1.11
R905.1.1.31 R905.1.1.31
R905.1.1.1]
Yes Yes
Yes
WIP 250HT Yes Yes No Yes Yes No liairrtstrips, {]pintstriips,
{joint strips,
1507.1.1.31 1507.1.1.31
1507,1.1.1 /
R90S.1.1.3] R905.1.1.3]
R905.3.1.1y
Yes
Yes
Yes
WIP 300HT
Yes
Yes
No
Yes
Yes
Yes
Uc1ntstrips,
{]flint strips,
00intstrips,
1507.1.1.31
1507.1.1,31
1507. L 1.11
R905.1.1.3)
R505.1.1.3}
R905.1.1.1}
Yes
Yes
Yes
WIP 400HT
Yes
Yes
No
Yes
Yes
Yes
t]oint strips.
Wnt strips,
Iloira st fps
1507.1.1.3/
1507.1, i.31
1507.1.1.11
R905.1,1,3}
R965.1.1.3}
R905.1.1.11
Yes
Yes
Yes
WIP GRIP
Yes
No
N0
No
No
No
ijoint strips,
ucirrt strips,
{]olnt strips,
1507.1.1.31
1507.1.1.3 1
1507.1.1.11
R905.1.1.3I
R905.3.3.3J
R905.1.1.1]
5.7 Al Iowa ble_Substrates:
TABLE 2: SUBSTRATE CIPTiONS
Underlayment
Primer
substrates
WIP 100, WIP 250HT
(Optional) CCW-702 or CAV-G RIP
Ply -Wood
WIP 100, WIP 250HT
None
ASTM D226 felt
WIP 1005G
CCW-702 or CAV-GRIP
plywood
WIP 300HT
(Optional) CCW-702 or CAV-GRIP
plywood, O5B or ASTM D226 felt
WIP 400HT
(Optional) CCW-702 or CAV-GRIP
plywood, 05B or ASTM D226 felt
WIP GRIP
(Optional) ASTM D41, 0CW-550, CCW-702 or CAV-GRIP
plywood
ASTM D41, CCW-550, CCW-702 or CAV-GRIP
OsB
NEMO ETC, LLC Evaluation Report C38180.12.11-R7
Centifkare Of AtithuMatfan 43240 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL678"10
Carlisle Coatings & waterproofing; (717) 245-7000 Revision 7: 08J13/2020
Page 3 of 5
5.8 Attachment Limitations.
ONEMOletc.
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
1-1:1a
5.8.3
5.8.3.1
#1
#2
5.9
5.10
For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but — for mechanical ly attached base sheets - not less than:
• FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table
1 (for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
■ Section 5.8.3 herein (far other underlayment systems).
Wind Resistance for Unde la ment Systems Tile Roof A lications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/T'RI
Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition. The Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
Pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TR1 Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical
(highest) design pressure determined in accordance with F B C 1509 or FBC Residential Chapter 3.
Maximum Design Pressure = -45.0 sf:
Deck: APA rated, min. 19/32 in. plywood sheathing to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Primer: (Optional) CCW 702 or CAV-GRIP
Underlayment: WIP 250HT, WIP 300HT or WIP 400HT, self -adhered.
Maximum Design Pressure = -45.0 osf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: CCW 702 or CAV-GRIP
Underlayment: WIP 400HT, self -adhered.
Exposure Li it tions:
TABLE 3: EXPOSURE LIMrrATIONS
Underlayment
Maximum Exposure (days)
WIP 100 and WIP 100sc
30
WIP GRIP
90
WIP 250HT, WIP 300HT and WIP 400HT
180
Tile SliplRage Um't tons:
When loading roof tiles On the underlayment in direct -deck tile assemblies, tile shall be staged atop a fastened
batten or toe -board, regardless of slope.
MEMO ETC, LLC Evaluation Report C38180.12.11-R7
COTtiflWR 01Authudzut►vn S32455 7`° EDITION (2ozo) Fsc NON-FIVHI EVALUATION FL5735-RIO
Carllsle Coatings & Waterproofing; (717y 245-7000 Revision 7: 08/13/2020
Page 4 of 5
4"
NTNEM01 etc.
6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings & Waterproofing installation
instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable) with CCW-702 or CAV-G RIP Primer.
Priming is required when temperatures are below 40'F.
6.3 WIP 100, WIP 1005G and WIP GRIP;
6.3.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 felt, the felt shall be fastened in accordance
with FBC 1507.1.1 or R905.1.1,
6.4 WIP 250HT, WIP 300HT and WIP 400HT:
6.4.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to
be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 felt, the felt shall be fastened in accordance
with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with requirements for a Self -Adhered Membrane in the FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Instarlation Manual, Sixth Edition, and the manufacturer's installation instructions.
Refer to 5.8.2 for attachment limitations.
Refer to Table 4 for the staging limitations.
7. BUILDING PERMIT REQUIRFMIENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
Contact the named OA entity for manufacturing facilities covered under F.A.C. Rule 61G20-3 qA requirements.
Refer to Section 4 herein for products & production locations having met cadif led material standards.
UL, I.L.C. — QUA9625; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report C39180.12.11-R7
Cenifrtate of Authorization 113Z455 7` EDITION (2020) FBC NON-MVMI EVALUATION FL6795-R10
Carlisle Coatings & Waterproofing; (717) Z45-7000 Revision 7: 08113/2020
Page 5 of 5