ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition �2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Required Sections of
Attachments Required
Roof System
the Permit Application
See List Below
Form
1,2,3,4,%6,7
_
Low Slope Application
A, B, C
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5A7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roofs A, B, D 1,2,3,4,6Tt;,T
Wood Shingles and A, B, D 1,2,4,5,6,7
Shakes
_
Other 1 _As Applicable 1,2,5,4,5,6,7
ATTACHMENTS REQUIRED As Applicable]:
1.
Fire Directory Listing Page
From Product Approval:
2.
Front Page
Specific System Description
Specific System Limitations
i
General Limitations
I Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCI E WORKS
Section A (General Information)
Master Permit No.
Process No.
Contractors Name: E� " �C i�f License #
Job Address L j
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
UPKs'phaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RA5 150
ROOF ROOF TYPE. ��//''
❑ New roof El Repair 0 Maintenance O'Reroofing ❑ Recovering
ROOF SYSTEM INFORMATIONI,
Low Slope Roof Area (SF) �0 Steep Sloped Roof Area (SF) _ 3 �7 Q5 Total (5F)iqlS
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval No.:
Design Wind Pressures, From RAS 128 or Calculations:
Zone 1': Zone 1: Zone 2: Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Type:
Gauge Thickness:
Slope-
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insuitation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheets)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—" oc @ Lap, # Rows— 41 "oc
Zone 1:_._." oc @ Lap, # Rows g "oo'
Zone 2:—" oc @ Lap, # Rows " 00
Zone 3:—" oc @ Lap, # Rows ® " 00
Number of Fasteners Per Insulation Board:
Zone 1': Zone 1- Zone 2.--Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
QuickMeasure
Roof Reports in Under an Hour
Bend lEave Rake Ridge
60 121 116 60
Lengths
Flash Step Drip
0 0 237
Lengths in feet
Prepared For: Pidgeline Roofing LLC U 5284 Russakis Rd, Fart Pierce, FL 34951
5T. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: r V1 r73
Notice of Acceptance Number: •V V "IV
w r f
Minimum design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: Zone 2e: Zone 2n:-Zone 2r: Zone 3e: Zone
-57.2- - 67.1- -6Z.9 "57. -Z -'72.4 T
Deck Type: f ��
Type Underiayment:
Roof 5iope:
' t insulation: r
Fire Barrier:
Ridge Ventilation? Fastener Type & Spacing:
Adhesive Type:
Type Cap Sheet
Mean Roof Height: Is- Roof Covering: j
Type & Size Drip p
Edge:
ST. LUCIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mr values
are greaterthan or equal to the
Mrvalues, for each area of the roof, then the tile attachment method is acceptable.
Method 1'Mom ent Based Tile Calculations Per RAS 12T
(Zone 1:
x _ __J - Mg: = M,, Product Approval M
(Zone 2e:
x 1, = �a - Mg: = M,;�a Product Approval Mf
(Zone 2n:
x ;L _ --Mg; =Mom, Product Approval Mr
(Zone 2r:
x _ - Mg: Me, Product Approval Mf
[Zone 3e:
x ). _ _) -- Mg. = Ma, Product Approval Mr
(Zone 3r:
X --J - Mg: = Mra, Product Approval Mf
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance
(Mr) From Table Below Product Approval Mf
Mr reuuired Moment Resistance* I
Mean Roof Height Roof Slope
15'
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
j 37.3
5:12
28.4
30.1
31.6 32.8
34.9
6:12
26.4
Z4.4
29.0
25.9
29.4
27.1
30.5
32.4
7.12
28.2
30.0
Must be used in conjunction with a list of moment based tile systems
• For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the file attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= ) -W; cos r =Fri Product Approval F'
(Zone 2e: x L =x W:= ) -W: cos r =Fr2e Product Approval F'
(Zone 2n: x L =x W:=_____) -W: cos r =Frzn Product Approval F'
(Zone 2r: x L =x W:=-___) -W: cos r =Frzr Product Approval F'
(Zone 3e: x L =x W:=_____) -W: cos r =Fr3e Product Approval F'
(Zone 3r: x L =x W:=-____ j -W: cos r =Fr3r Product Approval F'
Description
Design Pressure
Whereto Obtain Information
Symboi Where to find
From applicable table in RAS 127 or by an engineering analysis
Zones 1, Ze, 2n, Zr, 3e, 3r
prepared by PE based on ASCE 7
_
Mean Roof Height
H
Job Site
Roof Slope
9
Job Site
Aerodynamic Multiplier
a
Product Approval
Restoring Moment due to Gravity
Mg
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Mg
Calculated
Minimum Attachment Resistance
F'
Pro 6 u ct Ap prova I
Required Uplift Resistance
F,
Calculated f
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W =width
Product Approval
All calculations must be submitted to the building official at the time of permit application.