M MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
CertainTeed Corporation
18 Moores Road
Malvern, PA 19355
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
• r- n -emu -
DESCRIPTION CertainTeed Und'erlayment Systems
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 14-0724.16 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 141+028.02
MIAMt•DADB couNTY Expiration Date: 11/2 9
, Approval Date: 06/04/15
File Copy Page 1 of 9
ROOFING COMPONENT APPROVAL
Cateeory:
Roofing
Sub -Category:
Underlayment
Material:
SBS
SCOPE:
This approves CertainTeed Underlayment Systems, as described in this Notice of Acceptance; designed to comply with
the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Product
Specification Description
WinterGuard HT 36" x 65' ASTM D 1970 Modified fiberglass reinforced, bituminous sheet
Manufuring rolls material for use as an underlayment in sloped roof
Location #1 assemblies. Designed as an ice & rain shield.
WinterGuard Granular
36" x 65'
ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
Manufuring
rolls
bituminous sheet material for use as an
Location #2
underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
WinterGuard Sand
36" x 65'
ASTM D 1970 Embedded sand surfaced modified, fiberglass
Manufuring
rolls
reinforced, bituminous sheet material for use as an
Location #2
underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
Diamond Deck11" 48" x 250' ASTM D 226 Synthetic, scrim reinforced underlayment for use
Manufuring rolls Type H under shake, shingles, slate or metal roofing.
Location #3& 4
MetaLaymeni' 39 3/s" x 61' ASTM D 1970 A film surfaced, self -adhering underlayment for
Manufuring rolls use under metal roofing.
Location #1
Black Diamond' 39 3/s" x 68' 7" ASTM'D 1970 Granular surfaced modified, fiberglass reinforced,
Base Sheet rolls bituminous sheet material for use as an
Manufuring underlayment in sloped roof assemblies.
Location #2 Designed as an ice & rain shield. Not for use as
an Anchor Sheet. Direct adhesion to wood deck
not permitted in the HVHZ.
MAM4DADE couNTY NOA No.: 14-1028.02
... � Expiration Date: 11/24/19
Approval Date: 06/04/15
Page 2 of 9
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY .APPLICANT:
Product
Dimensions
Test
Product
Suecification
Description
Flintlastic GTA
39 3/8" x 32' 10"
ASTM D 6222
Granule surfaced APP Modified Bitumen
Manufuring
rolls
Grade G
membrane with non -woven polyester mat
Location #1
Type I
reinforcement for torch application.
All Weather/Empire
39 3/8" x 65' 10"
ASTM D 4601
Asphalt coated fiberglass reinforced base sheet.
Base Sheet
rolls
Type H
Manufuring
Location #1
DryRoor TU
39 3/8" x 61'
TAS 103
A polyester fabric surfaced, self -adhering
Manufuring
rolls
underlayment.
Location #1
Flintlastic GMS
39 3/8" x 32' 10"
ASTM D 6164
Granule surfaced SBS Modified Bitumen
Manufuring
rolls
Grade G
membrane with non -woven polyester mat
Location #1
Type I
reinforcement for mop application.
Flintlastic SA Cap
39 3/8" x 33' 11"
TAS 103
Polyester reinforced, self -adhering SBS modified
Manufacturing
rolls
bitumen cap sheet.
Location #1
Roofers.5elect_
36" x 144' rolls
ASTM D226
An asphalt -impregnated, organic felt reinforced
Manufacturing
Type I
with glass fibers, roofing underlayment.
Location #S
MANUFACTURING LOCATION:
1. Little Rock, AR.
2. Shakopee, MN
3. Hangzhou, China
4. Silvassa, India
5. Shreveport, LA
NOA No.: 14-1028.02
Expiration Date: 11/24/19
Approval Date: 06/04/15
Page 3 of 9
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Momentum Technologies, Inc.
AX31G8D
ASTM D4601
09/05/08
AX31 G8G
ASTM D6222
06/05/09
TrinitylERD
3530.12.05-1-R1
ASTM D1623
10/05/09
3523.03.05-R2
ASTM D1623
01/12/10
C32240.03.10
ASTM D4977
03/04/10
C3500.04.10
TAS 103
04/01/10
C31860.05.10
ASTM D1623
05/18/10
C30180.12.09-R2
ASTM D226
12/11/09
C31410.10.10-R1
ASTM D5147. ASTM D4798
11/02/12
C30890.03.10-1
ASTM D1970
03/17/10
C40050.09.12-2
ASTM D1970
09/28/12
C34940.09.11-R1
TAS 103, ASTM D1623
10/04/11
C32930.01.11-R2
ASTM D1623
01/20/14
C45240.01.14-1
ASTM D1970, TAS 110
01/15/14
C45240.01.14-2
TAS 103, TAS 110
01/24/14
PRI Construction Materials
CTC-075-02-01
ASTM D1623
10/07/11
Technologies, LLC
CTC-075-02-01
TAS 103
10/07/11
CTC-093-02-01
ASTM D6164, ASTM D4798
08/09/11
CTC-189-02-01
ASTM D1623
11/18/13
CTC-163-02-01
ASTM D6757, ASTM D226,
05/09/13
ASTM D4869
InterTek Testing Services Ltd.
10103165000Q-002C
ASTM D226
08/13/13
101227796COQ-003C
ASTM D4798
08/13/13
10103165000Q-005C
ASTM D4869
08/13/13
NOA No.: 14-1028.02
Miar�i•nauecouNnr Expiration Date: 11/24/19
Approval Date: 06/04/15
Page 4 of 9
APPROVED ASSEMBLIES:
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32' or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) One or more plies of Diamond Deck with a minimum 4" headlap and a 6" end
lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge
and in a grid pattern spaced 12" o.c. in the field of the roll.
(2:12 to < 4:12) One or more plies of Diamond Deck with a minimum 20" headlap and a 12"
end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset
36" minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor 3fi=4
(2:12 to < 4:12) Two plies of Roofers' Select with a minimum 19" headlap and a 12" end lap
mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and
in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset 72"
minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with
applicable Roofing Application Standards and Building Codes
NOA No.: 14-1028.02
Expiration Date: 11/24/19
Approval Date: 06/04/15
Page 5 of 9
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT,
WinterGuard Granular, WinterGuard Sand, MetaLayment, DryRoof TU or Black Diamond
Base Sheet self -adhering membrane adhered to the anchor sheet with a minimum 3" headlap
and 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to
obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the membrane is acceptable. If membrane is strapped, then anchor sheet must also
be strapped.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
NOA No.: 14-1028.02
Expiration Date: 11/24/19
Approval Date: 06/04/15
Page 6 of 9
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32' or greater plywood or wood plank
System E(4): - Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One ply of ASTM D 226 Type II organic felt or All Weather/Empire Base mechanically
attached with a minimum 4" side lap and a minimum 6"end lap. Anchor sheet shall be applied
at a right angle (900) to the slope of the deck with approved annular ring shank nails and tin
caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in
the field of the roll of the base sheet.
Ply Sheet: (Optional) One or more plies of an ASTM D226 ply sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane: One ply of Flintlastic GMS adhered in a full mopping of Type IV asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq. or Flintlastic GTA torch applied to the preceding sheet
or DryRoof TU, Flintlastic SA Cap, self -adhering membranes adhered to the preceding sheet
with a minimum 4" side lap and 6" end lap. Place the first course of membrane parallel to the
eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the
membrane is applied. Vertical strapping of the membrane is acceptable. If membrane is
strapped, then anchor sheet and ply sheet must also be strapped.
When used in Tile roof systems the cap sheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum of 12" o.c. at the side laps and 6" o.c. at the
end laps. No nails or tin caps shall be exposed.
Surfacing: *Flintlastic SA Cap, Flintlastic GTA, Flintlastic GMS and DryRoof TU may be used with any
approved roof tile system mechanically fastened as specified in their current NOA.
•Flintlastic SA Cap, Flintlastic GTA, Flintlastic GMS and DryRoof TU may be used with any
approved roof tile system adhered as specified in their current NOA using any foam adhesive
listed and having a current tile adhesive NOA approval.
Must comply with appropriate Roofing Application Standard RAS 118, RAS 119, RAS 120 and
applicable Building Codes.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
NOA No.: 14-1028.02
MLAMI-oave coExpiration Date: 11/24/19
Approval Date: 06/04/15
Page 7 of 9
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular,
WinterGuard Sand, Diamond Deck, MetaLayment, DryRoof TU or Black Diamond Base Sheet as a cap membrane
shall be acceptable for use in asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof
applications. CertainTeed underlayment roofing systems utilizing Roofers' Select shall be acceptable for use in
asphaltic shingles.
3. CertainTeed underlayment roofing systems utilizing DryRoof TU, Flintlastic SA Cap, Flintlastic GTA or
Flintlastic GMS as a cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened
roof tile systems as specified in the surfacing option of the approved assemblies.
4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. CertainTeed underlayment roofing systems shall be installed in strict compliance with
applicable Building Code.
5. CertainTeed underlayment roofing systems membranes shall be applied to a smooth, clean and dry surface with
deck free of irregularities.
6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a
recover system but may be applied over an approved roofing Base/Anchor sheet underlayment.
7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap,
MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof
for longer than 180 days of application. DryRoof TU and Roofers' Select shall not be left exposed as a temporary
roof for longer than 30 days after application.
8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing
CertainTeed underlayment products as a component part of an assembly in the Notice of Acceptance. If
CertainTeed underlayment products are not listed, a request may be made to the Authority Having Jurisdiction
(AHJ) or Miami -Dade County Product Control for approval provided that appropriate documentation is provided
to detail compatibility of the products, wind uplift resistance, -and fire testing results.
9. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
10. When applying the membrane in the valley, start at the low point ,and work to the high point, rolling the membrane
from the center outward in both directions.
11. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
12. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
13. The maximum roof slope for use as roof tile underlayment for direct -to -deck tile assemblies. shall be as follows:
(Limitations noted below are a result of the tile stacking/tile loading performance and do not reflect to that of the
underlayment. See Table Below) I
MIAMI•DADE COUNTY
NOA No.: 14-1028.02
Expiration Date: 11/24/19
Approval Date: 06/04/15
Page 8 of 9
LIMITATIONS:
Tile Profile
Flintlastic GMS'
Flintlastie SA Cape
DryRoorTV
Flintlastic GTA3
Flat Tile
4:12
6:12
6:12
6:12
Profiled Tile
4:12
5:12
6:12
6:12
'The following is applicable to all systems using and Flintlastic GMS:
•Slopes up to 4:12 — Stage by placing two tiles perpendicular to the slope followed by maximum four tiles on
top parallel to the slope for a total of 6 tiles. (Illustrated in Figure 1 below).
•Slopes greater than 4:12 — Horizontal batten strips are required. Stage tiles touching horizontal battens; a
maximum of 10 tiles shall be stacked parallel to the slope (See Figure 2 below).
'The following is applicable to all systems using Flintlastic SA Cap:
*Slopes up to 5:12, Profiled Tile — Stage by placing two tiles perpendicular to the slope followed by maximum
four tiles on top parallel to the slope for a total of 6 tiles. (Illustrated in Figure 1 below).
*Slopes greater than those shown in the above table — Horizontal batten strips are required. Stage tiles touching
horizontal battens; a maximum of 10 tiles shall be stacked parallel to the slope (See Figure 2 below).
'The following is applicable to all systems using DryRoof' TU and Flintlastic GTA:
•Tiles shall be stored on battens on roof pitches greater than 6:12".
Front View
Figure 1: Staged Method,
Front
View
Figure 2: Batten Method
END OF THIS ACCEPTANCE
Side View
Figure 2: Batten Method
NOA No.: 14-1028.02
Expiration Date: 11/24/19
Approval Date: 06/04/15
Page 9 of 9