Loading...
HomeMy WebLinkAboutEngineering File OPY F.i .ANFLORI D� Florida Engineering 4161 Tamiami Trail, Suite.101, Port Charlotte, FL 33952-9204 ENGINEERING www.flengineeringllc.com Phone: (941)391-5980 License Number#30782,#60102 ;November 12th,2021 ;Peterson Residence '7370 S Ocean Dr#715 I !Jensen Beach, FL 34957 Job No. 2131547, General Inputs Design Criteria,applicable codes and standards: Ultimate Wind Speed(mph) 175 Exposure Category D 1.2020 FBC(7th Edition),Ch. 16 Structural Design Mean Roof height(ft) 90 2.ASCE 7-16: Minimum Design Loads for Buildings Enclosure Type Enclosed and other Structures. Internal Pressure Coefficient(±) 0.18 Ch.30 Wind Loads-Components&Cladding Roof Pitch(in 12) 0 Minimum bldg dimension(ft) 50 Opening Width Height Effective External Pressure Internal Design Pressures no. wind area Zone Coefficient Pressure 1 Positive I Negative (in) (in) (sq.in) Positive Negative Coefficient (psf) 1 24.00 48.00 20.00 4 0.90 -0.90 0.18 58.59 -60.75 2 63.00 48.00 21.00 4 1 0.90 -0.90 1 0.18 58.56 -60.73 C 1 3 1 24.00 48.00 1 20.00 4 0.90 -0.90 1 0.18 58.59 -60.75 yt`e;ill${i�`F e0. '"".. r i .*fop��3 v lY/•a 5 a ,1.. '�,�^,�:•' . i CRAIG E.GUNDERSON,P.E.#60102 I