HomeMy WebLinkAboutTrussSEAT"PLATE BY CHAMBERS TRUSS
Jer
�j
I PRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SJJW6 FOR 4X2 EXCEPT AS SHOWN
ACARRIED CA f3 MANGER ID
FASTENER FOR
FASTENER FOR
TRUSS T SS
CARRIED TRUSS
CARRYING TRUSS
KJ7, K 7
GRA,G JA26
,
(7)-1 OD
(16)-16D
JP
G
KJG7
'Please refer to Standard Erring package for general instuction on installing hangers
10d=0.148' 16d=0.162" x 3 1/2"
W/AtA
,,,
NOTES:
" AL—borffEAMS ARE RY OTHERS.
EVEL RETURNS ARE BY BUILDER, REDUIRED BY TRUSSES.
E 11 DGE ., Rr- AND CONNECTIONS OF LEDG.::R ARE DESIGNED
ow-
'L
L
d Do not stand on trusses until they are braced per BCSI & proper) nailed to straps and h
Y p angers ..
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 8'-2"
END DETAIL: TYPICAL
2-0�0-00
4.5 r-
AND SUPPLIED BY OTHERS.
PLUMB CUT END
2X4 TOP CHORD 4.5 (—
WALL HEIGHT 8'-11"
END DETAIL: UTILITY PCH
4- j
i
2-00-00 5108
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 9'-l"
END DETAIL: PORCH
11
11
4-00-00
4.5 r—
PLUMB CUT END
2X4 TOP CHORD 4.5 r-
WALL HEIGHT 9'-6"
END DETAIL: UPTURN IBM
�1
FABRICATION AGREEMENT
i TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED 8 RETURNED
�,Ie undersigned acknowledges and agrees:
1.Trusseswillbe made in strictaccordance with this truss placement d' ramtermining successful fabrication of the trusses.' solo authority for
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of i
undersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Try shall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
kfter 10 days of delivery remedy win be according to Florida statute 558.
4. The undersigned acknowledges receipt of 'BCSI' summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has i
he sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss win' re responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has
o redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
esponsibte to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change N any changes are made in this layout A $50 per hour;
se for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
!voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
slivery if buyer cannot accept delivery of fabricated trusses, The undersigned agrees in pay Chambers Truss j-asonable attorneys fee for collections in event of payment not timely made. 1-1/2 % per month service charge wig be
dded for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to an terms herein.
I
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
ayment when due of any and all indebtedness awed to Chambers Truss by any entity receiving material and the i
x:ippient
ndersgned agrees to pay such indebtedness inducing attorneys fees, if default in payment for material be made by the
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
,rein, the parties agree that the sole venue for any such action win be Saint Lucie County, Florida. I
11. Design (responsibilities are per '"`National Standard And Recommended Guidelines On Responsibilities For
Dnstruction Using Metal Plate Connected Wood Trusses ANSI/TPUWTCA 4 - 2002'"'
12. Warranty is per Chambers Truss Warranty attached.
TED
TITLE
A spreader bar may be required per to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are j
set, failure to do so can result in roof collapse.
Temporary
po ry and permanent bracing are !red and can save life and property i
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per to prevent injury & damage.
Trusses must be set lumb and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS i
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
31105-01ii—ander Avenue
Fort Pierce, Florida 34982-6423
800-551-5932
Fort Pierce 772465-2012 Fax 772-465-8711
Vero Beach 772-569.2012 Stuart 772-286.3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
EIV;
S1'. Lucie County, Pere
iL-Wd2--CQ.unty, ,Permitting
DESIGN CRITERIA
LOADING/DESIGN CRITERIA REDUaBLE
rIER CODE SUCH As ssc 1G04.&I
County
ST. LUCIE
Building Department
ST. LUCIE COUNTY
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material
Shingle or Shake
Loading in PSF
Top Chord Live
Roof R.D.L. Floor
20
Top Chord Dead
0
20 4.2 0
Bottom Chord Live
'10-Non Conccurent 0
Bottom Chord Dead
10 3 0
Total Load
50 7.2 0
Duration Factor
1.25 0
'wind Speed
170mph
Top Chord C.B.
Sheathing by builder
!Bottom Chord C.B.
Sheathing by builder
!Highest Mean Height
15'
Building Type
Enclosed
Building Category
II: Non Restrictive
Exposure Category
Miles from Ocean
C>Open Terrain with scattered obstructions
5
Conforms to Florida Building Code 2017
R.D.L.=Restraining Dead Load
C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
I
Chambers Truss Inc. Drawing Name: 75240
SCALE: 3/16" = 1'-0"
137 total trusses, 67 unique designs
Designer: RLC Reviewed by: RLC i
Date: 07/03/18
FOR
KATHLEEN & HERBERT YANC�Pil,
DESCRIPTION:®
YANCY RES.
�
Page 1 of 1 CUSTOMER INITIALS EACH PAGE i
75240 ' i
LuMllei•'lc�esign•values are in accordance with ANSI/TPI 1 section 6.3
TMQ truss designs rely on lumber values established by others.
MiTek
RE: 75240 - YANCY MiTek USA, Inc.
Site Information: 6904 Parke East Blvd.
Tampa, FL 33610-4115
Customer Info: KATHLEEN & HERBERT YANCY Project Name: YANCY Model:
Lot/Block: Subdivision:
Address: N/A
City: PORT ST LUCIE State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 170 mph
Roof Load: 40.0 psf Floor Load: N/A psf
This package includes 66 individual, Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
I Date
No.
I Seal#
Truss Name
I Date
1
IT144829391A
7/5/18
118
1 T14482957
1 G2
7/5/18
12
1 T14482940
1 Al
1 7/5/18
119
1 T14482958
1 GRA
1 7/5/18
13
1 T14482941
I A2
1 7/5/18
120
1 T14482959
1 GRB
1 7/5/18 1
14
1 T14482942
1 ATA
1 7/5/18
121
1 T14482960
1 GRD
1 7/5/18 1
15
1 T14482943
1 ATB
1 7/5/18
122
1 T14482961
1 G RG
1 7/5/18 1
6
1 T14482944
1 ATC
7/5/18
123
1 T14482962
1 G R P
7/5/18
7
1 T14482946
1 ATK
1 7/5/18
124
I T14482963
I J 1
1 7/5/18
18
1 T14482947
1 ATL
1 7/5/18
125
I T14482964
I J 1 P
1 7/5/18 1
19
1 T14482948
1 ATM
1 7/5/18
126
I T14482965
I J3
1 7/5/18
110
1 T14482949
1 D
1 7/5/18
127
I T14482966
I J3B
1 7/5/18
11
I T1 4482950
1 D1
1 7/5/18
128
I T14482967
I J3P
1 7/5/18
112
J T14482951
1 D2
1 7/5/18
129
I T14482968
I J5
1 7/5/18
113
1 T14482952
1 D3
1 7/5/18
130
I T14482969
I J5P
1 7/5/18 J
114
1 T14482953
1 D4
1 7/5/18
131
I T14482970
I J7
1 7/5/18
15 1
T14482954
1 D5
7/5/18
132
IT14482971IJ7A
7/5/18
16 1
T14482955 1
G
1 7/5/18
133
I T14482972
I J7P
1 7/5/18
117 1
T14482956 1
G1
1 7/5/18
134
I T14482973
1 JA
1 7/5/18
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc. under my direct supervision based on the parameters
provided by Chambers Truss.
Truss Design Engineer's Name: Finn, Walter
My license renewal date for the state of Florida is February 28, 2019.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek's customers
file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
RECEIVED
AUG 0 8 2018
ST. Lucie County, Permitting
1LR P
ENiW* L
i
j
J/ No 22839
S OF T
4u
O �
N A,
Walter P. Finn PE No.22839
MiTek USA, Ind. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
Finn, Walter 1 of 2
RE: 75240 - YANCY
Site Information:
Customer Info: KATHLEEN & HERBERT YANCY Project Name: YANCY Model:
Lot/Block: Subdivision:
Address: N/A
City: PORT ST LUCIE State: FL
No.
Seal#
Truss Name I
Date
135 1T144829741JA1
1
7/5/18
136 I
T14482975 1
JA5 1
7/5/18
137 I
T14482976 1
JA7 1
7/5/18
138 I
T14482977 I
JB 1
7/5/18
139 I
T14482978 I
JB1 1
7/5/18
140 I
T14482979 I
JB3 1
7/5/18
141 I
T14482980 I
JB5 1
7/5/18
142 1
T14482981 1
JG3 1
7/5/18 1
143 1
T14482982 1
JG7
1 7/5/18
144
I T14482983 1
KJ7
1 7/5/18
145 1
T14482984 1
KJ7G
1 7/5/18
146 1
T14482985 1
KJA
1 7/5/1.8
147
1 T14482986 1
KJA7
1 7/5/18
148
1 T14482987 1
KJG7
1 7/5/18
149
I T14482988
1 KJP
1 7/5/18
150
I T14482989
1 P
1 7/5/18
151
1 T14482990
1 P1
1 7/5/18
152
1 T14482991
1 P2
1 7/5/18
153
1 T14482992
1 P3
1 7/5/18
154
1 T14482993
1 P4
1 7/5/18
155
I T14482994
I P5
1 7/5/18 1
156
1 T14482995
1 V5
1 7/5/18
157
I T14482996
I V23
1 7/5/18
158
I T14482997
1 VA
1 7/5/18
159
1 T14482998
1 VB
1 7/5/18
160
1 T14482999
1 VC
1 7/5/18
161
1 T14483000
1 VE
1 7/5/18
162
1 T14483001
I VF
1 7/5/18
163
1 T14483002
1 VG
1 7/5/18
164
1 T14483003
1 VH
1 7/5/18
165
1 T14483004
1 VK
1 7/5/18
166
I T14483005
1 VL
1 7/5/18
2of2.
Job
Truss
Truss Type
city
Ply
YANCY
t t
T14482939
75240
A
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 1.1 2018 MI I ek Industries, Inc. Thu Jul b U/:21:4U 2U18 rage 1
ID:fc6ZRoaxnh?vyJnkAMEaaizl kk3-I9jNapf9gyzKOT86hfBypoPaPFidmpUBsDM95uz?Blf
2-a-0 6-6-7 11-0-0 16-0-0 21-0.0 27-11-3
2-4-0 4-2-7 4-5-9 5-0-0 5-0-0 6-113
Scale: 1/4'=1'
4x5 = 4x6 =
3x4 =
_-- 4 19 20 5 21 22 6
m
N
12
4x8 = 6x8 = 4x8 = 3x5 I I
21-0-0
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017ITP12014
CSI.
TC 0.38
BC 0.33
WB 0.47
Matrix -MS
DEFL. in
Vert(LL) -0.09
Vert(CT) -0.18
Horz(CT) 0.02
Wind(LL) 0.14
(loc) I/defl L/d
9-11 >999 360
9-11 >999 240
16 n/a n/a
9-11 >999 240
PLATES GRIP
MT20 244/190
Weight: 176lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-1-11 oc purlins,
BOT CHORD 2x8 SP 240OF 2.0E
except end verticals.
WEBS 2x4 SP No.3 *Except`
BOT CHORD
Rigid ceiling directly applied or 9-6-0 oc bracing.
7-8: 2x4 SP M 30
OTHERS 2x8 SP 240OF 2.0E
REACTIONS. (lb/size) 12=1207/0-8-0, 16=968/0-7-4
Max Horz 12=115(LC 11)
Max Uplift 12= 799(LC 12), 16=-557(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1580/1135, 2-3=-1726/1308, 3-4— 1479/1079, 4-5=-1359/1085, 5-6=-1300/1078,
6-7=-1445/1058
BOT CHORD 1-12= 1088/1552, 11-12=-1253/1552, 9-11= 1124/1520, 8-9=-360/412
WEBS 3-11=-247/348, 4-11=-50/292, 5-11=-279/300, 5-9=-360/298, 6-9=-23/264,
7-9=-600/907, 2-12= 459/525, 7-16=-1323/1060
e
NOTES-
,1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 11-0-0, Exterior(2) 11-0-0 to
25-2-15, Interior(1) 25-2-15 to 27-2-3 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 16 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 799 lb uplift at joint 12 and 557 lb uplift
at joint 16.
Walter P. Finn PE No.22639
MiTek USA, Inc. FL Cori 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
®WARMING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAMSI/IPII QualityCdteda, DS&89 and BCS18uild(ng Component
6904 Parke East Blvd.
Solety Informallonovailable from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
YANCY
it t
T14482940
75240
Al
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:21:41 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-n1LHln9fnRF5BOdjlFMgBMOxk7f3TVGcK5t6idKz?Ble
2-4-0 6-10-5 7-11 13-0.0 19-0-0 23-3-14 27-11-3
2-4-0 4-6-5 -9-11 5-4-0 6-0-0 4-3-13 4-7-5
Scale: 114'=1'
4x6 = 4x6 =
20 21
4x8 = 3x6 Il 6x8 = 4x5 = Sx6 =
4x5 =
1-3
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress'Incr YES
Code FBC2017fTP12014
CSI.
TC 0.39
BC 0.30
WB 0.48
Matrix -MS
DEFL. in (loc) I/deft Ud
Vert(LL) -0.09 11-12 >999 360
Vert(CT) -0.17 11-12 >999 240
Horz(CT) 0.02 17 n/a n/a
Wind(LL) 0.12 11-12 >999 240
PLATES GRIP
MT20 244/190
Weight: 171 lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 5-8-15 oc purlins,
BOT CHORD 2x8 SP 240OF 2.0E
except end verticals.
WEBS 2x4 SP No.3 `Except'
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
7-8: 2x4 SP M 30
OTHERS 2x8 SP 240OF 2.0E
REACTIONS. (lb/size) 13=1207/0-8-0, 17=968/0-7-4
Max Harz 13=140(LC 11)
Max Uplift 13� 799(LC 12), 17=-557(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1470/923, 2-3=-1567/1053, 3-4=-1458/1087, 4-5= 1327/1077, 5-6— 1448/1097,
6-7= 391/288, 8-14=-5331757, 7-14=-533/757
BOT CHORD 1-13=-850/1406, 12-13=-1015/1494, 11-12— 1015/1494, 9-11=-884/1331, 8-9= 892/1164
WEBS 3-12=-227/324, 5-9=-39/253, 6-9=-46/280, 6-8=-1091/859, 2-13=-321/404,
7-17=-1234/899
•
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuit=170mph (3-second gust) Vasd=132mph; TCDL--4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 13-0-0, Exterior(2) 13-0-0 to
23-5-12, Interior(1) 23-5-12 to 27-2-3 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Bearing at joint(s) 17 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 799 lb uplift at joint 13 and 557 lb uplift
at joint 17.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03f2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
Bet
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabricallon, storage, delivery, erection and bracing of trusses and truss system, seeANSbVIF QualdyCdfeft DS049 and BCSI Building Component
6904 Parke East Blvd.
Safety InforinaNanovailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
YANCY
1 1
T14482941
75240
A2
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:21:42 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-EXr7?UgPCZD2dnlVp4BOvDUno3ObEfeUKXrF9mz?Bid
2-4-0 7-10-5 -8-0 15-0-0 17-0-0 22-3-14 27-11-3
2-4-0 5-6-5 -9-1 6-4-0 2-0-0 5-3-13 5-7-5
4x6 = 4x5 =
4.50 12
15 14 1e rr ru a
3x6 11 6x8 = 4x5 = 4x5 = 3x5 11
4x5 =
8-8-0
Scale = 1:49.3
9
6
oq
I
LOADING (psi)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CSI.
TC 0.90
BC 0.30
WB 0.36
Matrix -MS
DEFL. in (loc) I/deft L/d
Vert(LL) -0.07 12-14 >999 360
Vert(CT) -0.14 12-14 >999 240
Horz(CT) 0.02 19 n/a n/a
Wind(LL) 0.11 12-14 >999 240
PLATES GRIP
MT20 244/190
Weight: 182lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-7-5 oc puffins,
BOT CHORD 2x8 SP 240OF 2.0E
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x8 SP 240OF 2.OE
REACTIONS. (lb/size) 15=1207/0-8-0, 19=96810-7-4
Max Harz 15=165(LC 11)
Max Uplift 15— 799(LC 12), 19=-557(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1454/873, 2-4=-1579/1037; 4-5= 1311/998, 5-6=-1163/1005, 6-7=-1299/1017,
7-8— 1335/950
BOT CHORD 1-15=-824/1413, 14-15=-989/1413, 12-14= 989/1413, 11-12=-765/1163, 10-11=-838/1211,
9-10=-254/359
WEBS 4-14=-173/298, 4-12=-378/250, 6-11 =-1 89/268, 7-10=-298/326, 8-10=-623/902,
2-15=-402/492, 8-1 9=-1 249/862
Is
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45f; L=28ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 15-0-0, Extedor(2) 15-0-0 to
17-0-0, Interior(1) 21-2-15 to 27-2-3 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 19 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 799 Ib uplift at joint 15 and 557 lb uplift
at joint 19.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 114II-7473 rev. 10/03f2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSWII Quality Criteria, DSB-89 and SCSI Bullding Component
Tampa, FL 33610
Safety Wolmatb/pvailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Job
Truss
Truss Type
city
Ply
YANCY
1 t
T14482942
75240
ATA
ATTIC
6
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:21:44 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-BwzuQAigkAUmt4StwUDu_eZETs_3iaJmnrKMEfz?Bib
-4-0-13 -7- 8-0-0 12-11-3 15-6-2 20-7-0 25-10-6 29-11-3
7.4-12 4-11-3 2-6-15 5-0-14 5-3-6 4-D-13
O N
0 O
4.50 12
14
4x5 =
4x4 =
3x4 = 5xB MT19HS =
13
6x8 it
Scale=1:58.2
0-7-14
0-7-4
-4-0-7 0-0-1 n &0-0 15-6-2
15�7-3
20-7-0 25-10-6
29-10-13
4-0-7 0- 1 7.6-2
0. -1
4-1t-13 5-3-6
4-47
0-7-3
0-0-10
Plate Offsets (X Y)-- f2:0-4-0 0-2-121 r3:0-3-0 Edgel f7.0-4-8 Edgel r8:0-2-8 0-3-01r12:0-3-8,0-4-121,f13:0-5-8,0-3-01
LOADING (pst)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(LL) -0.16
13 >999 360
MT20
244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.69
Vert(CT) -0.30
13 >999 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.67
Horz(CT) 0.07
10 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.16
13 >999 240
Weight: 185lb
FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-7-12 oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E `Except`
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
7-13: 2x4 SP M 30
WEBS 2x4 SP No.3 *Except*
2-15,7-13: 2x4 SP M 30, 2-18: 2x8 SP 240OF 2.0E
REACTIONS. All bearings 0-7-3 except Qt=length) 10=Mechanical, 1=Mechanical.
(lb) - Max Harz 22= 205(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 10, 1 except 9= 663(LC 12), 22=-674(LC 12)
Max Grav All reactions 250 Ib or less at joint(s) 10, 1 except 9=1366(LC 19),
22=1351(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1697/828, 4-5=-1571/909, 5-6=-324/221, 7-8=-1961/1021, 8-9=-2484/1271
BOT CHORD 14-15= 254/471, 13-14= 528/1515, 12-13= 16/273, 7-12=-118/511111-12=-1015/2269,
9-11=-1013/2284
WEBS 8-12=-577/386, 5-17=-1323/748, 7-17= 1323/748, 2-14=-292/1124
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft L=26ft; eave=4ft; Cat.
. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -4-0-7 to-1-0-7, Interior(1) -1-0-7 to 12-11-3, Exterior(2)
12-11-3 to 15-11-3 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Ceiling dead load (5.0 psf) on member(s). 4-5, 5-17, 7-17
7) Bottom chord live load (30.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 13-14
8) Refer to girder(s) for truss to truss connections.
9) Bearing at joint(s) 22 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 1 except
Qt=lb) 9=663, 22=674.
11) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
Walter P.Finn PENo32839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
�•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
i
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, socAldS&VII Qualify Cr8edd, DSB-89 and SCSI 8ufldlrlg Component
6904 Parke East Blvd.
Safety fnfonnaffanavailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
YANCY
e t
T14482943
75240
ATB
ATTIC
3
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11. 2015 MI I eK Industries, Inc. I nu ,Jul b u/:21:4b 2u1B rage 1
ID:fc6ZRoaxnh?vyJnkAMEaoizt kk3-f6XGdW ilVUcdUE03UCk7Ws6SPGK7R5CWOV4vm5z?Bla
-4-0-13 -7- 7-9-3 8-9-7 12-,11-3 17-,0.15 21-2-1 25-3-2 2 -1 -6 29-11-3
4-0-13 -7- 7-1-15 1-0-4 4--12 4-1-12 4-1-2 4-1-2 -7 4-0-13
I109
O
=
4.50 12 4x4
3x4
—A � 3x4 = 8 3x4 =
23 22 19 17 16 15
5x6 = 3x5 11 54— 7-7-0 6x8 = 4x5 = 3x5 11
6x12 = 4x5 =
3x10 I I
B-9-7
B-9-3
-0-0-7 -7-A 7-9-3 7-11-3 17-0-15 21-2-1 25-3-2 2 -1 29-10-13
,N7 -7- 7-1-15 0- -00- -4 8-3-8 4-1-2 4-1-2 -7 4-0-7
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.30
Vert(LL)
-0.07
17
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.70
Vert(CT)
-0.16
17
>999
240
BCLL 0.0 *
Rep Stress Incr
YES
WB 0.37
Horz(CT)
0.02
26
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL)
0.12
17
>999
240
Scale = 1:63.1
4 N �
N TM
f
O
PLATES GRIP
MT20 244/190
Weight: 215 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 *Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
22-23,20-21,18-19,15-18: 2x8 SP 240OF 2.0E 6-0-0 oc bracing: 15-16.
WEBS 2x4 SP No.3 *Except*
2-25,13-26: 2x8 SP 240OF 2.0E
REACTIONS. All bearings Mechanical except at --length) 25=0-7-3, 20=0-8-0, 26=0-7-3.
(lb) - Max Horz 25=205(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) except 1=-108(LC 12), 14=-105(LC 12), 25=-538(1_C 12), 20=-247(LC
12), 26— 627(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 14 except 25=849(LC 1), 20=508(LC 18), 26=1017(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-10011735, 4-5= 854/774, 5-6=-870/787, 6-7=-733/713, 9-10= 731/693,
10-1 2=-795/637,12-13=-925/673
BOT CHORD 2-25=-767/650, 20-21=-399/802, 19-20=-109/329, 17-19=-331/691, 16-17— 466/827,
13-26= 997/730
WEBS 13-16=-583/974, 7-24=-635/522, 9-24=-635/522, 2-21=-411/759
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511; B=45ft; L=26ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=o.18; MWFRS (directional) and C-C Exterior(2) -4-0-7 to-1-0-7, Interior(1) -1-0-7 to 12-11-3, Extetior(2)
12-11-3 to 15-11-3 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 25, 26 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint 1, 105 lb uplift at
joint 14, 538 lb uplift at joint 25, 247 lb uplift at joint 20 and 627 lb uplift at joint 26.
8) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
�
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, noY
i
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing indicated is to buckling Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
prevent of
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/1P11 Qua1By 0yeda, DSB-89 and BCSI Buudfng Component
Tampa, FL 33610
Safety rnrotmadonavailabte from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type
City
Ply
YANCY
t �
T14482944
75240
ATC
ATTIC
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. I hu Jul 5 07:21:46 2U18 Nage 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-7J4ersjwGokU6ObG2vFM33fZYgnIAVv3E9pT1Yz?BIZ
i44-00-13 -2-113 7-10 _ 1 245232 26--71 Odb5 2891 47-12 4--2 4-20T 4-1-1
Scale=1:53.1
4x4 =
4.50 F12
18 17 i8-0-0 14 13 12
3x5 II 4x5 = 4x5g— x5 = 4x5 = 3x5 II
0-7-4
-4-0.7 0-7-3 4.8-6 8-11-7 17-0-15 21-2-1 25-3-2 2SI.10r6
4-0-7 -7- 4-1-1 4d•1 6-3-8 4-1-2 4-1-2 7-4
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0 *
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TP12014
CS1.
TC 0.53
BC 0.25
WB 0.54
Matrix -MS
DEFL. in (loc) 1/defl Ud
Vert(LL) -0.14 14-16 >999 360
Vert(CT) -0.23 14-16 >999 240
Horz(CT) -0.02 21 n/a n/a
Wind(LL) 0.10 14-16 >999 240
PLATES
MT20
Weight: 185 lb
GRIP
244/190
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 4-10-10
oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E *Except* BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
Except:
2-18,11-12: 2x4 SP No.3
6-0-0 oc bracing: 2-22
WEBS 2x4 SP No.3 WEBS
1 Row at midpt 6-8
OTHERS 2x8 SP 240OF 2.0E
REACTIONS. (lb/size) 1=92/Mechanical, 21=1070/0-7-3, 22=1240/0-7-3
-
Max Horz 22=185(LC 11)
Max Uplift 1— 96(LC 12), 21=-518(LC 12), 22= 660(LC 12)
Max Grav 1=92(LC 1), 21=1216(LC 20), 22=1380(LC 18)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1547/742, 3-5=-1779/808, 5-6=-1586/825, 8-9=-1587/841, 9-10= 1779/829,
10-11= 1461/743
BOT CHORD 2-22= 11861689, 16-17=-648/1483, 14-16=-586/1595, 13-14=-632/1342, 11-2l= 1138/643
WEBS 2-17=-633/1462, 3-17=-557/260, 5-16=0/425, 9-14=0/421, 6-20= 17791774,
8-20=-1779/774, 10-13=-657/301, 11-13=-629/1409, 10-14=-73/455, 3-16=-101/344
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2� Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=26ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Extefior(2) -4-0-7 to-1-0-7, Intedor(1) -1-0-7 to 12-11-3, Exterior(2)
12-11-3 to 15-11-3 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Ceiling dead load (5.0 psf) on member(s). 5-6, 8-9, 6-20, 8-20
6) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 14-16
7) Refer to girder(s) for truss to truss connections.
8) Bearing at joint(s) 21, 22 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 96 lb uplift at joint 1, 518 lb uplift at joint
21 and 660 lb uplift at joint 22.
10) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MIrEK REFERANCE PAGE M11-7473 rev. IOIW12015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
iViiTeV
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/JPII QualityCrBeda, DSB-89 and BCSI Bugd/gg Component
6904 Parke East Blvd,
Safety InfaimaBoeavatiabie from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
r +
T14482946
75240
ATK
Attic
11
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:21:48 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizt kk3-3hCOFYIAoP_CLile9Klg8UkvoTQ2eJMMiTIaNOz?BIX
-4-0-0 p-8-1 7-10-4 12-0-0 16-1-12 23-3-15 2(1-0-p 28-0-0
r 4-0-0 8- 7-2-3 4-1-12 4-1-12 7-2-3 8- 4-0-0
4.50 F12
avd =
4x4 =
Scale=1:54.8
I a
N Nim
ICO O
O
16 15 13 12
3x5 11 4x5 = 8 0 L5 = 3x5 11
-3-1
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0 *
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC20171TP12014
CSI.
TC 0.55
BC 0.36
WB 0.92
Matrix -MS
DEFL. in (loc) I/defl Ud
Vert(LL) -0.15 13-15 >999 360
Vert(CT) -0.25 13-15 >999 240
Horz(CT) -0.03 11 n/a n/a
Wind(LL) 0.12 13-15 >999 240
PLATES GRIP
MT20 244/190
Weight: 168lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 5-4-11 oc puffins.
BOT CHORD 2x4 SP No.3 *Except*
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
14-16,12-14: 2x8 SP 240OF 2.0E
WEBS 2x4 SP No.3 *Except*
2-19,10-18: 2x8 SP 240OF 2.0E
REACTIONS. All bearings Mechanical except Qt=length) 18=0-8-0, 19=0-8-0.
(lb) - Max Harz 19= 188(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) except 1=-101(LC 12), 11=-101(LC
12), 18=-614(LC 12), 19=-614(LC
12)
Max Grav All reactions 250 lb or less at joints) 1, 11 except 18=1312(LC 19),
19=1313(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1569/674, 4-5= 13891734, 5-6=-21/273, 6-7=-21/273, 7-8=-1389/734,
8-10=-1569/674
BOT CHORD 2-19— 1234/715, 13-15=-383/1386, 10-18= 12347715
OEBS 8-13=-96/304, 10-13=-318/1294, 4-15= 96/304, 2-15=-318/1257, 5-17=-1624734,
7-17= 1624/734
NOTES-
V Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 12-0-0, Exterior(2)
12-0-0 to 15-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Ceiling dead load (5.0 psf) on member(s). 4-5, 7-8, 5-17, 7-17
6) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 13-15
7) Refer to girder(s) for truss to truss connections.
8) Bearing at joint(s) 18, 19 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 lb uplift at joint 1, 101 lb uplift at
joint 11, 614 lb uplift at joint 18 and 614 lb uplift at joint 19. Welter P. Finn PE No.22839
10) Attic room checked for U360 deflection. MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verify design parameter; and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 10103=15 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, 'and Is for an Individual building component, not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAN!9WII CuallfyCd1edd, DSO-89 and SCSI Bulfd/ng Component
6904 Parke East Blvd.
Safety InformaKoncivailabie from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
I russ I ype •
ty
Ply
,
T14482947
75240
ATL
Attic
1
1
�YANCY
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Dec 12 2017 MiTek industries, Inc. Thu JUI 5 10:22:27 2018 Page 1
I D:fc6ZRoaxnh?vyJnkAMEaoizl kk3-xoO35ZIgOP W MLmVflVjk6Y20CZ69FK7tJCM7yLz?9XQ
34-0 6-3-7 , 11-10-4 1&fr1113;11-5 16-0-0 i 18-0-11 1$3-5 LOA 12 , 27.11-3
2-11a 5 s 13 1-toa o- - 0 2-011 2-0-11 0- o t-to 7 7-sa
4.50 12 4x4 =
7
4x9 = is 17 16 3x6 II 4x51= b%8 65 = 4x5 II
FASTEN TRUSS TO BEARING FOR
THE UPLIFT REACTION SHOWN
WHILE PERMITTING NO UPWARD
MOVEMENT OF THE BEARING.
2-0-0 3-4-0 4-6-44-�0 E3-7 11-10-4 20-1-12 27-11-3
2-0-0 1-4-0 5-6-13 8-3-8 7.9-7
Scale=1:47.0
Plate Offsets (X Y)-- 110:0-6-12 0-1-01 [11:Edge 0-3-81 j16:0-4-0,0-3-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(LL)
-0.15 12-14 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.27
Vert(CT)
-0.26 12-14 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.81
Horz(CT)
-0.01 23 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL)
0.14 12-14 >999 240
Weight: 180lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-0-8 oc purlins, except
BOT CHORD 2x8 SP 240OF 2.0E
end verticals.
WEBS 2x4 SP No.3 *Except* BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing, Except:
10-11: 2x4 SP M 30
10-0-0 oc bracing: 12-14,11-12.
OTHERS 2x8 SP 240OF 2.0E
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 2-8-0 except Qt=length) 18=0-3-8, 23=0-7-4.
(lb) - Max Horz 17=177(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) except 17=-1483(LC 18), 16= 1195(LC
12), 18= 234(LC 12), 23=-425(LC 12)
Max Grav All reactions 250 lb or less at-joint(s) 18 except 17=606(LC 12), 16=3130(LC
18), 16=2209(LC 1), 23=1058(LC 19)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-24=-319/502, 2-24= 314/524, 2-3= 485/1201, 3-4=-1506/639, 4-5=-1424/647,
5-25=-1314/697, 6-25=-12821700, 8-26=-1283/688, 9-26=-1315/685, 9-1 0=-1 470/598
BOT CHORD 1-1 8=-473/364,17-18= 473/364, 16-17= 452/232, 15-16_ 138/266, 14-15=-138/266,
13-14=-465/1304, 12-13=-465/1304, 11-12=-298/536
WEBS 3-14=-455/1389, 5-14� 116/296, 6-19=-1548/687, 8-19=-1548/687, 10-12= 176/854,
• 2-17=-173/717, 3-15= 571/275, 3-16=-1496/718, 2-16=-851/265, 10-23=-1517/770
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; 13CDL=3.0psf; h=15ft; B=45ft L=28ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-0-0 to 3-0-0, Interior(l) 3-0-0 to 16-0-0, Exterior(2) 16-0-0 to
19-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 pst bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Ceiling dead load (5.0 psf) on member(s). 5-6, 8-9, 6-19, 8-19
6) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 12-14
7) Bearing at joint(s) 23 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
Walter P. Finn PE No.22839
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1483 lb uplift at joint 17, 1195 lb uplift at
MiTek USA, Inc. FL Cert6634
joint 16, 234 lb uplift at joint 18 and 425 lb uplift at joint 23.
6904 Parke East Blvd. Tampa FL 33610
9) This truss has large uplift reaction(s) from gravity load case(s). Proper connection is required to secure truss against upward
Date:
movement at the bearings. Building designer must provide for uplift reactions indicated.
10) Attic room checked for U360 deflection.
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
��9 �p iYl'tW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSWI1 QualityCdleda, DSB-89 and BCSI80ding Component
6904 Parke East Blvd.
Safety lnfomlof/on3vailable from truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
t
T14482948
75240
ATM
Attic
6
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:21:61 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-TGuXuZn34KMniC9UDgTrXm7MLLhSniQoOQXE_Iz?B1U
2-4-0 34-0 6-37 11-10-4 138-11 1 1 -5 160-0 18-0-11 1 5 20-1-12 27-11-3
2-4-0 7-0-0 2-11-7 5-6-13 1-10-7 0- - 0 2-0-11 2-rr 0- - 0 1.10-7 7-9-7
4x5
4.50 12
Scale = 1:47.5
3x6 11 4x5'= 6x8 = 4x5 = 4x5 11
3.4-0
2-0-0 6-3-7 11-10-4
20-1-12
27-11-3
2-0-0 6A 2-11-7 5-9-13
8-3-8
7-9-7
1-0-0
Plate Offsets (X Y)-- f1:0-6-9 0-1-121 f2:0-4-12 2-2-01 f10:0-6-12 0-1-01 fll:Edge 0-3-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.79
Vert(LL) -0.23
12-14 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.36
Vert(CT) -0.41
12-14 >742 240
BCLL 0.0 *
Rep Stress Incr YES
WB 0.58
Horz(CT) 0.02
21 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL) 0.23
14 >999 240
Weight: 174lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-1-7 oc purlins,
BOT CHORD 2x8 SP 240OF 2.0E
except end verticals.
WEBS 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
10-11: 2x4 SP M 30
WEBS
1 Row at midpt 6-8
OTHERS 2x8 SP 240OF 2.0E
REACTIONS. (lb/size) 16=1283/0-8-0, 21=1057/0-7-4
Max Horz 16=177(LC 11)
Max Uplift 16=-753(LC 12), 21=-503(LC 12)
Max Grav 16=1380(LC 21), 21=1224(LC 20)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1863/698, 2-3=-1858/762, 3-5= 1983/846, 5-6=-1749/868, 6-7—
87/402,
7-8=-76/391, 8-9= 1765/883, 9-10= 1979/826
BOT CHORD 1-16— 603/1707, 15-16- 755/1824, 14-15=-755/1824, 12-14=-677/1778, 11-12=-313/568
WEBS 3-14= 237/299, 5-14=0/460, 9-12=-49/378, 6-17= 2201/956, 8-17=-2201/956,
10-12=-375/1346, 3-15= 473/340, 10-21=-1719/877
NOTES-
1) Unbalanced roof live loads have been considered for this design.
?� Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 16-0-0, Exterior(2) 16-0-0 to
19-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Ceiling dead load (5.0 psf) on member(s). 5-6, 8-9, 6-17, 8-17
6) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 12-14
7) Bearing at joint(s) 21 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 753 lb uplift at joint 16 and 503 lb uplift
at joint 21.
9) Attic room checked for U360 deflection.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M117473 rev. 10103)2015 BEFORE USE.
Design valid for use only wilh MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MO
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUWII Qualdy Cged a OSB-89 and BCSI Building Component
Tampa, FL 33610
Safety Informaiianavallabie from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
oTruss
Truss Type
Qty
Ply
T14482949
75240
D
Hall Hip
1
1
�YANrY
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 S Dec 12 2017 Ml rek Inauslrres, Inc. I nu Jul 5 1D:44:15 2018 Yage 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-206hFgcOGChL7EDdbKIAI?rho 1 ZbwlXrmgR?Ssz?9Cx
2-4-0 6-6-7 11-0-0 16-10-0 22-7-15 23-0r0
2-4-0 4-2-7 4-5-9 5-10-0 5-10-0 D=4-i
4
1
0
is
4x8 =
4x5 =
2x3 11
1617 5 18
4x8 =
46 =
Sx10 =
3x4 =
Scale=1:39.2
23-0-0
22.11.12
2-0-0 -4- 6-6-7 11-0-0
16-10-0
22-6-8 22- 1
2-0-0 -4- 4-2-7 4-s-9
- 5-10-0
5-8-8 0- 7
0-3-13
0-OA
Plate Offsets (X Y)-- (2:0-5-12 0-2-0] f4:0-5-4 0-2-0] (6:0-2-8 0-2-121 f 10:0-5-0,0-6-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.25
Vert(LL) -0.04
9-10 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.22
Vert(CT) -0.07
9-10 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.63
Horz(CT) -0.01
11 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.05
9-10 >999 240
Weight: 159lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x8 SP 240OF 2.0E
end verticals.
WEBS 2x4 SP No.3 `Except'
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
6-7: 2x4 SP M 30
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x6 SP No.2
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 11 =1 018/0-8-0 (min.0-1-8), 14=774/0-3-0 (min. 0-1-8)
Max Harz 14=256(LC 12)
Max Uplift 11=-674(LC 12), 14=-460(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1020/607, 2-15=-1086/689, 3-15= 10711700, 3-4=-1150/847, 4-16=-893/706,
16-17=-893/706, 5-17=-893/706, 5-18=-893/706, 6-18=-893/706
BOT CHORD 1 -11 =-533/969, 10-11_ 533/969, 9-10=-513/952, 8-9=-547/1040
WEBS 4-9=-72/270, 5-8=-390/416, 2-11=-229/306, 6-8=-745/952, 3-10=-307/367,
6-14=-782/611
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 11-0-0, Extedor(2) 11-0-0 to
15-2-15 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 14 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 674 lb uplift at joint 11 and 460 lb uplift at
joint 14.
LOAD CASE(S) Standard
Walter P. Finn PE No12839
MiTek USA, Inc. FL Ced 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITekQ connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
�'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSMPII Quality Crffedd, DSB-89 and BCS1 BuUd/ng Component
6904 Parke East BNd.
Safety IMoneaBonavaliabie from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
0I
fuss
Truss Type
Qty
Ply
YANCY
i r r
T14482950
75240
D1
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Dec 122017 Mu eK inaustnes, inc. i nu dui 5 1U:4/:U8 2U18 rage i
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-4jNywzgeER6DW NDIYl o2esu5QZa1IF7ts7c?R?z?9AH
i 2-4-0 6.10-5 7-8-0 13-0.0 21-0-0 i 23-9-13 2LI14
2-4-0 4-6-5 0-9-11 5-4-0 8-0-0 2-9-13 -0-
Scale=1:42.0
4x8 =
sxs =
18 19 20 21 5 4x6 =
12 __ '
4x8 = 3x6 I I 6x8 4x5 =
4x8 = 3x6 =
24-1-14
2-0.2 -4- 7-8-0 13-0-0
21-0-0 23-24 1- 0
5-4-0 5-4-0
.9-13
8-0-0 2-9-13 0- 3
0-0.4
Plate Offsets (X Y)-- r2:0-3-4 2-1-81 (2:0-0-11 0-1-121 r4:0-5-4 0-2-41 (5:0-3-0 0-2-61 r6:0-3-4,0-2-01,(12:0-0-0,0-1-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL) -0.04
9-11 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.24
Vert(CT) -0.09
9-11 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.28
Horz(CT) 0.01
15 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.07
9-11 >999 240
Weight: 168lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS
1 Row at midpt 4-8
OTHERS 2x6 SP No.2
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 12=1063/0-8-0 (min. 0-1-8), 15=821/0-3-0 (min. 0-1-8)
Max Horz 12=243(LC 12)
Max Uplift 12=-700(LC 12), 15=-488(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1136/681, 2-16=-1239/803, 3-16= 1225/817, 3-17= 1138/863, 4-17=-1036/877,
4-18= 525/499, 18-19— 525/499, 19-20=-525/499, 20-21=-525/499, 5-21=-525/499,
5-6=-567/473
BOT CHORD 1-12= 628/1102, 11-12= 902/1102, 10-11— 902/1102, 9-10=-902/1102, 8-9— 821/1024
WEBS 3-11=-217/304, 4-9= 78/376, 4-8= 599/476, 5-8=-218/289, 6-8— 575/733, 2-12=-337/427,
• 6-15=-827/693
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 13-0-0, Extedor(2) 13-0-0 to
23-6-10 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3), Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 15 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 700 lb uplift at joint 12 and 488 lb uplift at
joint 15.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11,1II-7473 rev. 10/0312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Addilional temporary and permanent bracing
Rg
ek'
Mi LT
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSWII Auaf ry CrBedd, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety fnfomrationavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
I russ
Truss Type
aty
Ply
YANCY
T14482951
75240
D2
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Dec 12 2017 Mffek Industries, Inc. Thu Jul 5 10:48:25 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-JXX341bx55pIFCc5Zig5F5aI1 brgl2QCZcmael z?994
25-3-11
i 2-0-0 i 7-10-5 8-8-0 15-0-0 i 19-0-0 24-10-3 24-11-11
2-4-0 5-6-5 0-9-11 64-0 4-0-0 5-10-3 0- 7
0-0-1
Scale=1:45.0
1
I
0
4x8 =
4x5 =
4.50 12 5
18 6
16 "
I 1i�
1
0
4x8 = 3x6 II 6x8 =
4x5 = 4x8 = 3x6 =
4x6 =
25-3-11
25-3-8
i 2-0-0 2 4- 8-8-0 15-0-0 19-0-0 i 24-10,3 24-11-11
� 4- 6-4-0 6-4-0 4-0-0 5-10-3 0- 7
0-3-13
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.34
Vert(LL)
-0.05 10-12 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.26
Vert(CT)
-0.11 10-12 >999 240
BCLL 0.0
Rep Stress Incr
YES
WB 0.39
Horz(CT)
0.01 16 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL)
0.08 10-12 >999 240
Weight: 176lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD 2x8 SP 240OF 2.0E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x6 SP No.2
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 13=1109/0-8-0 (min.0-1-8), 16=867/0-3-0 (min. 0-1-8)
Max Horz 13=216(LC 12)
Max Uplift 13=-732(LC 12), 16=-510(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1256/754, 2-17=-1382/901, 3-17=-1368/901, 3-4= 1262/918, 4-18= 1087/857,
5-1 8=-1 014/870, 5-19— 765/732, 6-19=-765/732, 6-20=-815/715, 20-21= 817/706,
7-21=-879/703
BOT CHORD 1-13=-713/1229, 12-13=-955/1229, 11-12— 955/1229, 10-11= 955/1229, 9-10=-741/958
WEBS 4-12=-153/286, 4-10=-366/256, 5-1 0=-1 78/371, 5-9= 391/307, 7-9=-482/690,
2-13= 404/496,'7-1.6= 882/718
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=25ft; eave=oft Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, interior(1) 3-0-0 to 15-0-0, Exterior(2) 15-0-0 to
19-0-0, Interior(1) 23-2-15 to 24-8-7 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 16 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 732 lb uplift at joint 13 and 510 lb uplift at
joint 16.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
®WARNING - Verily design parameters and READ NOTES ON THIS. AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 10103/201S BEFORE USE
Design valid for use only with MITek8 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�e
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
i
MiTek?
Is always required for stabillty and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSYMI1 QuaMy CIII&M, DSB-89 and BCSI BDlldIng Component
6904 Parke East Blvd.
Safety Infomta8'onovailable, from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
JOTruss
I rusS I ype
Qty
Ply
YANCY
r r
714482952
75240
D3
Roof Special
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Dec 12 2017 MiTek Industries, Inc. Thu Jul 5 10:48:56 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaojzl kk3-vUvnbuzOodjvTzU2tjkMOdMcV5Qg32umiwnjDkz?98b
26-5-9
2-4-0 6-1-12 11-6-14 17-0-0 21.6-12 26-0-1 26r1�&
2-4-0 3-9-12 5-5-2 5-5-2 4-6-12 4-5-5 0. 7
0-4-1
4x4 = Scale=1:47.2
4.50 F12
•
3x6
4
3x4
20
5
6
21 2x3 I I
7
22
4x10
8
4x8 II 19
2-
0
2x3 11
3
F FZ
18
q
Io
15
14
13 12
11 10 9
4xS =
3x6 11
6x8 =
4x5 = 4x5 = 3x6 =
3x6 11
4x6 =
26-5-9
2-0-0 2 -
6-1-12 10-3-3
17-0-0
26-1-8 2 -5 5
2-0-0
3-9-12 4-1-6
6-&13
9-1-8 0-2-13
O-Od
Plate Offsets (X Y)-- (2:0-5-12 0-2-01 (8:0-3-4 0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.26
Vert(LL)
-0.05 13 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC
0.28
Vert(CT)
-0.11 11-13 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB
0.53
Horz(CT)
0.01 18 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix
-MS
Wind(LL)
0.08 13 >999 240
Weight: 172 lb FT = 20%
LUMBER-
BRACING-
-
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x6 SP No.2
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS. (lb/size) 15=1155/0-8-0 (min. 0-1-8),18=914/0-3-0 (min.0-1-8)
Max Harz 15=190(LC 12)
Max Uplift 15= 762(LC 12), 18=-533(LC 12)
Max Grav 15=1155(LC 1), 18=915(LC 19)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 1-2=-1375/739, 2-19=-1418/814, 3-19=-1404/824, 3-4= 1424/922, 4-5= 1324/931,
5-20=-988/755,6-20=-934/764,6-21=-9341794,7-21=-978/782,7-22= 896/663,
8-22=-964/656
BOT CHORD 1-15=-654/1286, 14-15=-856/1335, 13-14= 856/1335, 12-13=-856/1335, 11-12= 856/1335,
10-11=-551/872
WEBS 3-14=-246/271, 5-11=-599/381, 6-11= 235/420, 7-10= 298/344, 8-10=-493/857,
8-18=-932/684
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=26ft; eave=oft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 17-0-0, Exterior(2) 17-0-0 to
20-0-0 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Bearing at joint(s) 18 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 762 lb uplift at joint 15 and 533 lb uplift at
joint 18.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for on Individual building component, not
a truss system. Before use, the building designer must verify The applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
Is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, sooANSVW11 Qualdy Ciffedo, OSR-89 and SCSI SuQding Component
6904 Parke East Blvd.
Sofefy fnfollnaflonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
JoTruss
Truss Type ,
Qty
Ply
�YANCY
T14482953
75240
D4
Roof special
1 .
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Dec 12 2017 MiTek Industries, Inc. Thu Jul 5 10:49:24 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-StbMTTJyCEFxgGdRW bEx8XWMHOzncheu8HZCC7z?989
23-6-10
-0-0-13 0-7-4 6-9-3 8-10-6 , 12-11-3 17-0-0 ,1841 23-1:2 23r2-�
4-0.13 -7- 6-1-15 2-1-3 4-0-13 4.0-13 1-0-14 5-0d 4
0.4-1
Scale = 1:49.3
4x4 =
4.50 12
12
3x5 I I
4x8 = 6x8 = 4x8 =
0 Q
3x6 =
4x6 =
6
N
14 -7
T
23-6-10
-4-0-s 0-7-4 8-10-6 i2-113
17-0-0 23-2-9 23-&6
4-0-6 -7- 8-3-2 4-0.13
4.0-1-3 6-2-9 0- - 3
"-4
Plate Offsets (X,Y)--12:0-7-4,0-0-81,(7:0-2-12,0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL) -0.04
9-11 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.37
Vert(CT) -0.07
9-11 >999 240
BCLL 0.0 *
Rep Stress Incr YES
WB 0.61
Horz(CT) -0.01
14 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.05
9-11 >999 240
Weight: 178lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E *Except* BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
2-12: 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 SP No.3 *Except*
be installed during truss erection, in accordance with Stabilizer
2-13: 2x8 SP 240OF 2.0E
Installation guide.
OTHERS 2x6 SP No.2
REACTIONS. (lb/size) 1 =1 06/Mechanical, 13=1095/0-7-3 (min. 0-1-8), 14=862/0-3-0 (min. 0-1-8)
Max Harz 13=173(LC11)
Max Uplift 1= 104(LC 12), 13=-672(LC 12), 14= 498(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1197/770, 3-4=-10971781, 4-16=-1158/933, 5-16=-1133/944, 5-17=-976/880,
6-17=-1032/869, 6-18=-970/731, 7-18=-1034/722
BOT CHORD 2-13=-1010/773, 11-19-482l788, 10-19= 482/788, 10-20— 482/788, 9-20= 482/788
WEBS 2-11=-489/890, 4-11= 393/452, 5-11=-330/496, 5-9=-202/309, 6-9=-345/401,
7-9= 453/752, 7-14=-889/658
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -4-0-7 to-1-0-7, Interior(1) -1-0-7 to 12-11-3, Exterior(2) 12-11-3
to 15-113 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where af-ectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 13, 14 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 1, 672 lb uplift at joint
13 and 498 lb uplift at joint 14.
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
,& WARNING - Verllydesign parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE M11-7473 rev. 1010=015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
i1lliTW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUIPII Qualfty CNeda, DSB-89 and BCSI BuRding Component
6904 Parke East Blvd.
Safety InfounaHon3vailable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
I russ
Truss Type
Qty
Ply
YANCY
T14482954
75240
D5
Root Special
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Dec 12 2017 MiTek Industries, Inc. Thu Jul 5 10:49:58 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-5QfDc5iHCgX6vVDzW krvXiwDV5dEa5auyao_08z?97d
-0-0-13 0-7- 5.0-0 6-9-3 8-6-5 12.11.3 17-4-2 21-0-0 24-4-7
4-0.13 -7- 4-4- 22 1-9.3 1- IA 4-0-14 4.4-15 3-7-14 3-0-7
44 =
4.50 F12
Scale = 1:51.3
D__
16 15 14
12 11 10
3x5 11 4x5 = 4x5 = 6x8 =
4x5 = 45 = 3x6 =
4x6 =
24-8-7
24-8-4
A-0-7 7 8-6-5 174-2
21-0-0 24-2-15 24 -
4-0.7 -7 7-11-1 B-9-13
3-7-14 3-2-15 0- 7
0-3-13
0.0-4
Plate Offsets (X Y)-- f9:0-3-4 0-2-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL,
in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.22
Vert(LL) -0.06
12-14 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.15
Vert(CT) -0.12
12-14 >999 240
BCLL 0.0 *
Rep Stress Incr YES
WB 0.45
Horz(CT)
0.01 18 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Wind(LL)
0.07 12-14 >999 240
Weight: 188lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD 2x8 SP 240OF 2.0E *Except* BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
2-16: 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 SP No.3 *Except*
be installed during truss erection, in accordance with Stabilizer
2-17: 2x8 SP 240OF 2.0E
Installation guide.
OTHERS 2x6 SP No.2
REACTIONS. (lb/size) 17=1137/0-7-3 (min. 0-1-8), 1=110/Mechanical, 18=909/0-3-0 (min. 0-1-8)
Max Horz 17=179(LC 11)
Max Uplift 17= 694(LC 12), 1=-108(LC 12), 18=-525(LC 12)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3= 11911763, 3-4=-1177/835, 4-5= 1136/845, 5-20=-1182/954, 6-20=-11361963,
6-21 =-1092/955,7-21=-1137/946, 7-8=-1134/853, B-9= 1116/746
BOT CHORD 2-17= 1144/816, 14-15= 672/1064, 14-22=-525/863, 13-22= 525/863, 13-23=525/863,
12-23=-525/863, 11-12=-647/1022
WEBS 2-15=-708/1176, 5-14=-246/299, 6-14=-255/428, 6-12=-218/373, 7-12= 244/300,
8-11=-237/274, 9-11= 555/928, 9-18=-943/689
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15fh B=45ft; L=25ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -4-0-7 to-1-0-7, Interior(1) -1-0-7 to 12-11-3, Exterior(2) 12-11-3
to 15-11-3 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 17, 18 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 694 lb uplift at joint 17, 108 lb uplift at
joint 1 and 525 lb uplift at joint 1 B.
LOAD CASE(S) Standard
Walter P. Finn PE No,22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
0 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. IOM312015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. &acing Indicated is to buckling of Individual truss web and/or chord members only. Addtllonal temporary and permanent bracing
MiTeW
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. for general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, sooANSUMI Quality Crlreda, DSO-89 and SCSi Building Component
6904 Parke East Blvd.
Safety Intotmationavallabie from Truss Plate Institute- 218 N. Lee Street. Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
r
T14482955
75240
G
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:21:56 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizlkk3-gEhQxHrCvs_3JwMBdORiTA31bi1TW 18YYiE?fzz?BIP
2-4-0 6-6-7 11-0-0 15-4-0 19-8-0 23-0-0 30-0-0 34-0-0
2-4-0 4-2-7 4-5-9 4-4-0 4-4-0 3-4-0 7-0-0 4-0-0
4.50 F12
4x6 = 3x4 = 3x4 II 4x8 =
4 524 25 6 7
Scale = 1:58.7
16 — 14 13 12
6x8 = 4x5 = 3x5 it ADEQUATE
4x5 = SUPPORT
REQUIRED.
1-0-0 15-4-0 19-8-0 23-0-0
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017/TPI2014
CS1.
TC 0.43
BC 0.84
WB 0.55
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/defl Ud
-0.17 12-13 >999 360
-0.33 12-13 >999 240
0.03 9 n/a n/a
0.27 12-13 >999 240
PLATES GRIP
MT20 244/190
Weight: 191 lb FT=20%
LUMBER-
`
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-5-5 oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E "Except`
BOT CHORD
Rigid ceiling directly applied or 9-2-9 oc bracing.
6-12: 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 9=89/Mechanical, 8=1343/0-8-0, 16=1291/0-8-0
Max Harz 16=140(LC 11)
Max Uplift 9— 61(LC 12), 8=-754(LC 12), 16= 852(LC 12)
Max Grav 9=92(LC 18), 8=1343(LC 1), 16=1291(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1798/1302, 2-3— 1977/1513, 3-4=-1776/1323, 4-5— 1658/1322, 5-6=-2538/1941,
6-7=-2533/1936, 7-8=-2294/1679
BOT CHORD 1-16=-1272/1775, 14-16=-1295/1875, 13-14=-1034/1723, 12-13= 189/266,
11 -1 2=-1 97/277, 6-11= 255/279, 10-11 =-1 352/2091, 8-1 0=-1 349/2082
WEBS 3-14=-181/292, 4-14=-1141333, 5-13=-798/669, 11-13=-889/1539, 5-11— 770/1070,
7-11=-455/659, 7-10= 62/268, 2-16=-580/648
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft L=30ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 11-0-0, Exterior(2) 11-0-0 to
27-2-15, interior(1) 27-2-15 to 33-11-10 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 61 lb uplift at joint 9, 754 lb uplift at joint
8 and 852 lb uplift at joint 16.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 1010312015 BEFORE USE,
Design valid for use only Win MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a hiss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building deslgn. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
r► /r
MiTek'
Is always required for stability and to prevent collapse wilh possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, so0AAISM11 Qualify Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safely rnionnaffanavallable from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482956
75240
G1
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:21:57 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-IQFo8dsggA6wx4xNBjyx?OcT06U2FTAhmM_YBPz?BIO
2-4-0 6-10-5 8- 13-0-0 19-8-0 21-0-0 25-4-5 30-0-0 34-0-0
2-4-0 4-6-5 -9-1 5-4-0 6-8-0 1-4-0 4-4-5 4-7-17 4-0-0
4x8 = 3x4 11 45 =
4 25 2627 285 6
3x6 ll 6x8 = 4x8 = 3x5 11 ^V
25-4-5 29-11-3
Scale=1:68.8
ADEQUATE
SUPPORT
REQUIRED.
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2017[TP12014
CSI.
TC 0.39
BC 0.43
WB 0.63
Matrix -MS
DEFL. in
Vert(LL) -0.11
Vert(CT) -0.22
Horz(CT) 0.05
Wind(LL) 0.16
(loc) I/deft Ud
13 >999 360
13 >999 . 240
9 n/a n/a
13 >999 240
PLATES GRIP
MT20 244/190
Weight: 204lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-5-10 oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E `Except`
BOT CHORD
Rigid ceiling directly applied or 9-9-9 oc bracing.
5-13: 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 9=97/Mechanical, 8=1334/0-8-0, 17=1292/0-8-0
Max Harz 17=165(LC11)
Max Uplift 9=-67(LC 12), 8— 747(LC 12), 17=-853(LC 12)
Max Grav 9=102(LC 18), 8=1334(LC 1), 17=1292(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1562/1024, 2-3=-1658/1152, 3-4= 1686/1298, 4-5=-2181/1730, 5-6=-2096/1659,
6-7=-2260/1687, 7-8=-2273/1680
BOT CHORD 1-17=-943/1493, 16-17=-966/1499, 14-16=-966/1499, 13-14=-205/302, 5-12=-263/309,
11-12=-1220/1962, 10-11=-1415/2096,.8-10=-1415/2096
WEBS 3-16=-330/386, 12-14=-778/1262, 4-12=-547l780, 6-11= 437/593, 7-10=
230/265,
2-17=-316/402
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=151111t; B=45ft; L=30ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 13-0-0, Exterior(2) 13-0-0 to
25-4-5, Interior(1) 25-4-5 to 33-11-10 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 67 lb uplift at joint 9, 747 lb uplift at joint
8 and 853 lb uplift at joint 17.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
�'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANS&VIl QuaBty CrBeda, DSB-89 and SCSI Bulld/ag Component
6904 Parke East Blvd.
Safety fntonnaBOnavailable from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482957
75240
G2
Hip
1
1
Jab Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:21:58 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-mcpAMzsSRUEnYEWZIRTAYb8g3Vox_zQq?Oj5jrz?BIN
-4-0-13 -7- 5-9-4 10-11-3 14-11-3 1 -7 20-7-8 25-10-6 29-11-3
4-0-13 -7- 5-2-0 5-2-0 4-0-0 8 5-0-5 5-2-14 4-0-13
17
ADEQUATE 3x5 II
SUPPORT
REQUIRED.
4.50 12
4x8 =
30 11
3x6 =
16 15 14
4x5 = 4x5 = 3x5 11
3Xb I I 4M =
scale = 1:60.2
Ir9
Tc IC;
o
ADEQUATE
SUPPORT
REQUIRED.
-4-0-7 -7- 5-10-11-3 15-7-3
-
20-7-8 25-10-6 291014
4-0-7 -7 5-2-09-4
5-2-0 4-8-0
5-0-5 5-2-14 4-0--8
Plate Offsets (X Y)-- (2:0-2-4 0-2-01 (5:0-5-4 0-2-01,f6:0-3-0,0-2-61,(13:0-2-12,0-3-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL, in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.31
Vert(LL) -0.06
13 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.52
Vert(CT) -0.12
12-13 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.44
Horz(CT) 0.02
11 n/a n/a
BCDL 10.0
Code FBC2017TFP12014
Matrix -MS
Wind(LL) 0.08
13 >999 240
Weight: 186 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 5-0-10 oc purlins.
BOT CHORD 2x4 SP No.3 *Except* BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
14-17,10-13: 2x8 SP 240OF2.OE
WEBS 2x4 SP No.3 *Except*
2-18: 2x8 SP 240OF 2.0E
REACTIONS. All bearings 0-7-3 except Gt=length) 11=Mechanical, 1=Mechanical.
(lb) - Max Horz 18=182(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 11 except 10=-689(LC 12), 1=-105(LC 12), 18=-724(LC 12)
Max Grav All reactions 250lb or less at joint(s) 11, 1 except 10=1226(LC 1), 18=1185(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-1216/888, 4-5=-1222/1043, 5-6=-1446/1262, 6-7=-1410/1236, 7-8=-1646/1292,
8-10=-2084/1521
BOT CHORD 2-18=-1108/847, 15-16=-667/1137, 7-13=-130/315, 12-13=-1259/1916, 10-12=-1259/1916
WEBS 2-16=-725/1146, 4-16=-319/397, 8-13= 471/381, 13-15= 620/1084, 5-13= 356/567
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft B=45ft; L=26ft; eave=oft; Cat.
- 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -4-0-7 to-1-0-7, Interior(1) -1-0-7 to 10-11-3, Exterior(2)
10-11-3 to 14,-11-3, Interior(1) 19-2-2 to 29-10-13 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Refer to girder(s) for truss to truss connections.
7) Bearing at joint(s) 18 considers parallel to grain value using ANSI/FPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except Gt=lb)
10=689, 1=105, 18=724.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors, This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
k
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSMII QuaBfy Cdfeda, DSB-89 and BCSI BUBd/ng Component
6904 Parke East Blvd.
Safety ►nfatmaffanavailable from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Oty
Ply
YANCY
'
T14482958
75240
GRA
Hip Girder
1
1
Job Reference (optional)
cnamoers I russ, Inc., ion vierce, rL
2-4-0 4-10-5 `a-8-0i
2-4-0 2-0-5 -9-11
4.50 12
midu s Iwar i i Zutts Iva I eK Inausrnes, Inc. I nu aui 6 u/:ZZ:uu Zults rage 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-j?xxneuiz5VVoYgyssVedOE?nJY8SsA7SKCCokz?BIL
9-0-0 13-8-9 18-3-7 23-0-0 1 27-11-3
3-4-0 4-8-9 4-6-13 4-8-9 4-11-3
Special NAILED NAILED
4x4 = Special
NAILED 3x4 = NAILED NAILED 3x4 = NAILED 4x4 —
4 21 22 23 5 24 25 6 26 27 28 7
4X8 = 3x6 I 4X8 = NAILLU 6x8 = 3X6 11 NAILtU 3X6 11 NAILtu 4X8 = 4X5 11
THJA26 NAILED NAILED NAILED NAILED
Scale: 1 /4'=1'
20 m
m
Ir
00
9-0-0
13-8-9
18-3-7
_3-0-0
27-11-35-8-0-0-0
04
4--9
-8-9
4-11-30
Plate Offsets (X Y)--
(1:0-5-5 0-1-81 (2:0-4-12 2-2-01 (8:0-6-12,0-1-01,f9:Edge,0-3-81
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in
(loc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.36
Vert(LL)
-0.07
12
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.28
Vert(CT)
-0.14 11-12
>999
240
BCLL 0.0
Rep Stress Incr NO
WB 0.48
Horz(CT)
0.02
20
n/a
n/a
BCDL 10.0
Code FBC2017[TP]2014
Matrix -MS
Wind(LL)
0.13
12
>999
240
Weight: 177 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x8 SP 240OF 2.0E
WEBS 2x4 SP No.3 *Except* BOT CHORD
8-9: 2x4 SP M 30
OTHERS 2x8 SP 240OF 2.0E
REACTIONS. (lb/size) 16=1253/0-8-0, 20=1221/0-7-4
Max Harz 16=115(LC 8)
Max Uplift 16_ 101 O(LC 8), 20=-868(LC 8)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1291/892, 2-3=1338/970, 3-4= 1755/1431, 4-5= 1647/1386, 5-6=-2229/1743,
6-7= 1576/1203, 7-8=-1701/1227
BOT CHORD 1-16=-797/1205, 15-16= 912/1256, 14-15=-912/1256, 12-14=-1647/2229,
11-12= 1647/2229, 10-11=-1647/2229, 9-10=-325/444
WEBS 3-15=-565/514, 3-14= 433/530, 4-14=-203/481, 5-14=-834/457, 5-12=0/276,
' 6-10= 851/670, 7-10= 130/356, 8-10=-824/1185, 8-20=-156311125
Structural wood sheathing directly applied or 4-10-0 oc puffins,
except end verticals.
Rigid ceiling directly applied or 9-3-8 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
B) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=28ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 20 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
16=1010,20=868.
8) Use Simpson Strong -Tie THJA26 (THJA26 on 1 ply, Left Hand Hip) or equivalent at 9-0-6 from the left end to connect truss(es) to
front face of bottom chord.
9) Fill all nail holes where hanger is in contact with lumber.
10) "NAILED" indicates 3-1 Od (0.148"xX) or 3-12d (0.148"x3.25") toe -nails per NDS guidlines.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 112 lb down and 197 lb up at
9-0-0, and 100lb down and 204 lb up at 23-0-0 on top chord. The design/selection of such connection device(s) is the
responsibility of others.
12) in the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. l aW/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This deslgn is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSMI i Quality CrIfedd, DSB-89 and BCS1 Building Component
6904 Parke East Blvd.
Safety lnformat�navaliable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa,FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482958
75240
GRA
Hip Girder
1
1
Job Reference (optional)
L:namDers I russ, Inc., tort Fierce, I-L 8.130 s mar 11 2019 MI I eK Industries, Inc. I nU JUI 5 07:22:00 2018 Page 2
ID:fc6ZRoaxnii?vyJnkAMEaoizl kk3-j?xxneuiz5VVDYgyssVedOE?nJY8SsA7SKCCokz?BIL
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-60, 4-7=-60, 7-8=-60, 1-9=-20
Concentrated Loads (lb)
Vert: 4=65(F) 7=-30(F) 14=1(F) 10=-166(F=-17) 21=65(F) 23=-3OtF) 24=-30(F) 25=-30(F) 26— 30(F) 28=-30(F) 30=-17(F) 31=-17(F) 32=-17(F) 33=-17(F) 34=-17(F)
®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MII-7473 rev, f 0/03J2015 BEFORE USE,
Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTeW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSt//P// BualByCrBeda, DSB-89 and BCSI BuHd&gComponent
6904 Parke East Blvd.
Safety fnfomlaHonavailable from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
'
T14482959
75240
GRB
Roof Special Girder
1
2
Job Reference c• tionai
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:01 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-BBUJ_vKkPdLPhF8QZOtADm6ejnCBFRHharmKAz?BIK
4 7-4 4-4-9 8-1-14 11-11-3 15-8-8 19-5-13 1 23-3-2 2$-10r6
7- 3-9-5 3-9-5 3-9-5 3-9-5 3-9-5 3=9-5 7-
7x141
5x8 MT18HS =
ALL CONCENTRATED LOADS
MUST BE EQUALLY DISTRIBUTED
TO EACH PLY OF THE TRUSS.
14 13 12 10 9 8
3x5 II 1ox10 = 8x10 = 8x14 MT18HS WB = 8xIO = 1Ox1O =
3x5 II
Scale = 1:44.4
iHS =
0-7-4 3-9-5 3-9-5 ' 1-6-2 ' 4-6-6 1-6-2 3-9-5
3-9-5 0-7-4
Plate Offsets (X,Y)-- [9:0-3-8,Edgel, [10:0-3-8,0-6-01, [12:0-3-8,0-6-01, [13:0-3-8,Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.61
Vert(LL) -0.23 10-12 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.68
Vert(CT) -0.47 10-12 >568 240
MT18HS 244/190
BCLL 0.0 *
Rep Stress Incr NO
WB 0.74
Horz(CT) 0.04 16 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Wind(LL) 0.47 10-12 >576 240
Weight: 355 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly
applied or 3-11-7 oc purlins.
BOT CHORD 2x4 SP No.3 *Except* BOT CHORD Rigid ceiling directly applied or 9-3-13 oc bracing.
11-14,8-11: 2x8 SP 240OF 2.0E
WEBS 2x4 SP No.3 *Except*
7-9,1-13: 2x4 SP M 30
OTHERS 2x8 SP 240OF 2.0E *Except*
11-11: 2x4 SP No.3
REACTIONS. (lb/size) 15=7805/0-7-3, 16=7805/0-7-3
Max Horz 15=901(LC 5)
Max Uplift 15= 6489(LC 8), 16=-6474(LC 8)
Max Grav 15=10273(LC 15), 16=10264(LC 15)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-12408/7776, 2-3=-12511/7920, 3-4=-12383/7936, 4-5— 1239417959,
5-6=-1 2521/7941, 6-7=12420/7800
BOT CHORD 14-15=-366/588, 1-15=-9700/6122, 12-13=-7245/11641, 10-12=-5579/8981,
9-1 0=-7266/11622, 8-16=-373/594, 7-16=-9688/61 01
WEBS 4-10=-3120/4968, 5-10=-101/331, 6-9= 514/408, 7-9= 7924/12695, 4-12=-308214937,
3-12=-104/331, 2-13=-522/416, 1-13=-8006/12742
NOTES-
1) N/A
2) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-7-0 oc.
Bottom chords connected as follows: 2x4 - 1 row at 0-7-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
4) Unbalanced roof live loads have been considered for this design.
5) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft B=45ft L=24ft; eave=4fh Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
6) All plates are MT20 plates unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Walter P. Finn PE No.22839
will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf.
MiTek USA, Inc. FL Cert 6634
9) Bearing at joint(s) 15, 16 considers parallel to grain value using ANSIlFPI i angle to grain formula. Building designer should verify
6904Parke East Blvd.Tampa FL 33610
capacity of bearing surface.
Date:
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
15=6489, 16=6474.
July 5,2018
A WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10)0 0IS BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
,
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
{�� T
I V 1 W
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSb7P11 HUalffyCrBedd, DSB.89 and BCSI Building Component
6904 Parke East Blvd.
Safety(nfolmallonovailabie from Truss Plate Institute. 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482959
75240
GRB
Roof Special Girder
1
n
S
Job Reference (optional)
Chambers I fuss, Inc., F-on Pierce, FL 8.130 s Mar 11 2018 MITek Industries, Inc. Thu Jul 5 07:22:02 2018 Page 2
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-fO2hBKwyVilC 1 rgL_GY6iRJH077RwigOwehJscz?BIJ
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pif)
Vert: 1-4=-60, 4-7=-60, 8-14=-638(F=-618)
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev, 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon. parameters shown, and is for an Individual building component not
�'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent twckiing of Individual truss web and/or chord members only. Additional temporary and permanent bracing
WeW
is always required for stability and to prevent collapse with possibie personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSWFI1 QualifyClBedd, DSB-69 and BCS1Building Component
6904 Parke East Blvd.
Safety Btfomtationavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314.
Tampa, FL 33610
Job
fuss
rus5 I ype
ty
Ply
r
T74482960
75240
GRD
Halt Hip Girder
1
1
�YANCY
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Dec 12 2017 MiTek Industries, Inc. Thu Jul 5 10:50:40 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-sVB5QSEdJapByyQ2zZbIEZgN5Ow?03V4c6zCsjz?96z
21-10-2
2-4-0 4-70-5 5-&0 9-0-0 13-2-1 17-4-1 21.4-10 21r6-2 1
-4-0 2-65 0-X01 3-4-0 4-2-1 4-2-1 4-0-9 0_4L7
0.4.1
Scale = 1:37.6
Special NAILED NAILED 4x6 =
4x8 2x3 II 2x3 II 4x10 =
NAILED NAILED NAILED
4 18 5 19 20 6 21 7
3x6 II 4x5 = — ___ 4x5 = " " 4x5 = 3x6 =
THJA26 NAILED
NAILED NAILED
21-10-2
i 2-0-0 a=4-0 5-8-0 9-0-0 13-2-1 i 17A-1 i 21-6-2 21r9-15
2-0.r 0 d-4-b 21N 3-4-0 4-2-1 4.2-1 4-2-1 01343
0-OA
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.27
TCDL 10.0
Lumber DOL 1.25
BC 0.28
BCLL 0.0 '
Rep Stress Incr NO
WB 0.61
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x8 SP 240OF 2.0E
WEBS 2x4 SP No.3
OTHERS 2x6 SP No.2
REACTIONS. (lb/size) 14=1262/0-8-0 (min. 0-1-8),17=99210-3-0 (min. 0-1-8)
Max Harz 14=21 O(LC 8)
Max Uplift 14=-1003(LC 8), 17=-725(LC 5)
DEFL. in
(loc) I/dell Ud
PLATES GRIP
Vert(LL) 0.1510-12
>999 240
MT20 244/190
Vert(CT)-0.1610-12
>999 240
Horz(CT) 0.01
17 n/a n/a
Weight: 145 lb FT = 20%
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-4-11 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 9-5-11 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-1266/903, 2-3=-1311/957, 3-4= 1810/1448, 4-18=-1388/1057, 5-18=-1388/1057,
5-19=-1388/1057, 19-20=-1388/1057, 6-20=-1388/1057, 6-21 =-I 388/1057,
7-21=-1388/1057
BOT CHORD 1-14= 817/1182, 13-14=-990/1204, 12-13= 990/1204, 11-12=-1408/1692,
11-22=-1408/1692, 10-22= 1408/1692, 10-23=-1057/1388, 9-23=-1057/1388
WEBS 3-13— 621/549, 3-12=-496/602, 4-12=-374/553, 4-10=-453/446, 5-10=-280/288,
• 6-9=-372/384, 7-9=-1218/1593, 7-17=-1005/736
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10: VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Bearing at joint(s) 17 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1003 lb uplift at joint 14 and 725 lb uplift
at joint 17.
8) Use Simpson Strong -Tie THJA26 (THJA26 on 1 ply, Right Hand Hip) or equivalent at 9-0-6 from the left end to connect truss(es) J7
(1, ply 2x8 SP), KJ7 (1 ply 2x8 SP) to back face of bottom chord.
9) Fill all nail holes where hanger is in contact with lumber.
10) "NAILED" indicates 3-1 Od (0.148" &') or 3-12d (0.148"x3.25") toe -nails per NDS guidlines.
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 204 lb down and 360 lb up at
9-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others.
12) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MIfEK REFERANCE PAGE M11-7473 rev. I M3/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component not
Rai'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
storage, delivery, erection and bracing of trusses and truss systems, seeANS&VII AualBy Cdfedd, DSB-89 and SCSI BUlld/ng Component
6904 Parke East Blvd.fabrication,
Safety fnfonnoffonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
russ
russ Type
Qty
Ply
YANCY
T14482960
75240
GRIDHalt
Hip Girder
1
1
Job Reference (optional)
cnam0ers I russ, MC., t-on V10Me, VL
O. 13V JUW IL — If IVIii-11IU11 Ii—, 11 IV. IIIY UYI � II/.�u.Y�c�Io �aaoc
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-sVB50SEdJap6yyQ2zZbl EZgN50w?Q3V4c6zCsjz?96z
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-4=-60, 4-7=-60, 1-8=-20
Concentrated Loads (lb)
Vert: 4=-157(B) 12_ 165(B) 10=-17(B) 5=-30(B) 6=-30(B) 9=-17(B) 18= 30(B) 20— 30(B) 21=-30(B) 22=17(B) 23=-17(B) 24= 17(B)
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MD-EK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
�y
MiTeW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSWIl OualllyCrBeda, DSO-69 and 8CS1 SuQd/ng Component
6904 Parke East Blvd.
Safety fnfomratfonavailabte from Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
YANCY
T14482961
75240
GRG
Hip Girder
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:05 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-3zkggMymd7nuJYvfP5pK3xknK77709sccwzTxz?BIG
2-4-0 4-10-5 8- 9-0-0 14-4-0 19-8-0 25-0-0 30-0-0 34-0-0
2-4-0 2-6-5 9-1 3-4-0 5-4-0 5-4-0 5-4-0 5-0-0 4-0-0
0
0
Special NAILED NAILED NAILED
5x8 = 6x12 MT1BHS =
4.50 12 NAILED NAILED 4x5 = NAILED 3x4 I NAILED Special
4 23 24 5 25 26 276 28 29 7
3x6 II 3x6 II 6X8 = 5x12 = NAILED
THJA26 NAILED NAILED NAILED
14-4-0 19-8-0
J4 NAILED
5x6 11
NAILED
3-11-11
Scale = 1:58.5
ADEQUATE
SUPPORT
REQUIRED.
LOADING (psf)
TCLL 20.0
TCDL 10.0
BCLL 0.0 *
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017ITP12014
CSI.
TC 0.85
BC 0.80
WB 0.88
Matrix -MS
DEFL. in
Vert(LL) 0.57
Vert(CT) -0.63
Horz(CT) 0.08
(loc) I/deft Ud
12 >582 240
12 >528 240
9 n/a n/a
PLATES
MT20
MT18HS
Weight: 194 lb
GRIP
244/190
2441190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-3-11
oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E *Except*
BOT CHORD
Rigid ceiling directly applied or 7-0-12 oc bracing.
6-12: 2x4 SP M 30
WEBS
1 Row at midpt 7-11
WEBS 2x4 SP No.3 *Except*
11-13,5-11: 2x4 SP M 30
REACTIONS. (lb/size) 9=68/Mechanical, 8=1972/0-8-0, 17=1975/0-8-0
Max Harz 17=114(LC 7)
Max Uplift 9-92(LC 25), 8=-1354(LC 8), 17=-1567(LC 8)
Max Grav 9=126(LC 14), 8=1972(LC 1), 17=1975(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -Ali forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 3056/2300, 2-3= 3085/2363, 3-4=-3075/2437, 4-5=-4114/3197, 5-6-5950/4430,
6-7=-5984/4445, 7-8=-4107/2963
BOT CHORD 1-17=-2100/2841, 16-17=-2106/2841, 15-16=-2106/2841, 1.3-15=2100/2834,
12-13= 505/686, 6-11= 425/4211 10-11=-2617/3828, 8-10-2605/3802
WEBS 4-13=-1046/1556, 5-13=-1342/1099, 11-13= 2569/3540, 5-11-1316/1958,
7-11-1721/2323, 7-1 0=-1 63/434
NOTES-
11 Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 13=45ft; L=30ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except at=lb)
8=1354,17=1567.
9) Use Simpson Strong -Tie THJA26 (THJA26 on 1 ply, Right Hand Hip) or equivalent at 9-0-6 from the left end to connect truss(es) to
back face of bottom chord.
10) Use Simpson Strong -Tie THJA26 (THJA26 on 1 ply, Left Hand Hip) or equivalent at 24-11-10 from the left end to connect truss(es)
to back face of bottom chord. Walter P. Finn PE No.22839
11) Fill all nail holes where hanger is in contact with lumber. MiTek USA, Inc. FL Cad 6634
12) "NAILED" indicates 3-1Od (0.148"x3") or 3-12d (D.148"x3.25") toe -nails per NDS guidlines. 6904 Parke East Blvd. Tampa FL 33610
13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 204 lb down and 363 lb up at Date:
9-0-0, and 108 lb down and 217 lb up at 25-0-0 on top chord. The design/selection of such connection device(s) is the
responsibility of others. July 5,2018
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MIrEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MiTek® connectors. this design Is based only upon parameters shown, and Is for an Individual building component, not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
mV9i iT®k7
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSMII Aualffy CrBeda, DS9.89 and BCSI SuQd(ng Component
6904 Parke East Blvd.
Safety(nformatfonavailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14462961
75240
GRG
Hip Girder
1
1
Jab Reference (optional)
Chambers I cuss, Inc., Fort fierce, FL t3.1 su s mar 11 zui is mi I eK Inausrnes, Inc. i nu dui b u/:ZZ:uo zui b rage z
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-3zkggMymd7nuJYvfP5pK3xknK77709sccwzTxz?BIG
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4= 60, 4-7= 60, 7-8=-60, 8-9=-81, 1-12=-20, 11-20=-20
Concentrated Loads (lb)
Vert:4=-157(B) 7= 36(B)15=-165(B)I0= 117(B) 23=-102(B) 24=-102(B) 25=-102(B) 26=-1 02(B) 27=-30(B) 28=-32(B)29— 32(B) 30=-49(B) 31= 49(B) 32=49(B)
33=-49(B) 34=-17(B) 35=-52(B) 36=-52(B)
® WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek8 connectors. This design Is based only upon parameters shown, and is for on Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek7
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUIPII GUa1lfyCdleda, DSB-89 and SCSI SUgd01g Component
6904 Parke East Blvd.
Safety intannaManavailable from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandda, VA 22314.
Tampa, PL 33610
Job
Truss
Truss Type
Qty 1
Ply
YANCY
T14482962
75240
GRP
Hip Girder
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:07 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizi kk3-?LsaF1 z5JFNV7cilmg7HPUOBi8xsbzH93wP4Ygz?BIE
4-0-0 q-5-a 3-8-12 1 -0 11-2-0 15-4-0 18-7.4 21-1%11 2�-4;0 25-7-3
4-0-0 5- 3-3-4 3-T 4-2-0 4-2-0 3-3-4 3-3-4 -5-t3 3-3-3
Special- NAILED
48 = Special
NAILED 2x3 11 NAILED 48 =
n cn 4 20 21 5 22 6
�11
ADEULIAIE
SUPPORT
REQUIRED. 3x5 II 4x5 = 4x5 = 6x8 = 4x5 = 4x5 = 3x5 II
THJA26 4x8 = THJA26
NAILED
3-11-10 0-5-8 3-8-12 7-0-0 11-2-0 15-4-0 18-7-4 21-10-8 22-4T
17 16 15 NAILED 13 NAILED 12 11 10
Scale=1:50.8
ADEQUATE
SUPPORT
REQUIRED.
LOADING (psf)
TOLL 20.0
TCDL 10.0
BOLL 0.0 *
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TPI2014
CSI.
TO 0.38
BC 0.21
WB 0.65
Matrix -MS
DEFL. in
Vert(LL) 0.09
Vert(CT) -0.10
Horz(CT) 0.00
(loc) Well Ud
13 >999 240
13 >999 240
1 ri/a n/a
PLATES GRIP
MT20 244/190
Weight: 179 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 4-5-15 oc purlins.
BOT CHORD 2x4 SP No.3 *Except* BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
14-17,10-14: 2x8 SP 240OF 2.0E
6-0-0 oc bracing: 2-18,16-17,8-19.
WEBS 2x4 SP No.3 *Except*
2-18,8-19: 2x6 SP No.2
REACTIONS. All bearings 0-3-8 except at=length) 1=Mechanical, 9=0-1-0.
(lb) - Max Harz 18=127(LC 7)
Max Uplift All uplift 100 lb or less at joints) 9 except 1=-106(LC 25), 18= 1215(LC 8), 19=-1192(LC 8)
Max Grav All reactions 250 lb or less at joints) 1, 9 except 18=1724(LC 1), 19=1694(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1664/1221, 3-4=-2224/1676, 4-5=-2394/1832, 5-6=-2394/1832, 6-7= 2228/1679,
7-8=-1675/1227
BOT CHORD 2-18=-1649/1190, 15-16— 1009/1518, 13-15=-1366/2050, 12-13— 1369/2054,
11-12= 1016/1528. 8-19— 1617/1166
WEBS 2-16=-1155/1714, 3-16_ 789/598, 3-15=-529/740, 4-13=-324/510, 5-13=-582/566,
6-13=-320/506, 7-12=-545f737, 7-11=-784/595, 8-11 =-1 145/1697
NOTES-
-r) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and fight exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Bearing at joint(s) 18, 19 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 9.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except Qt=lb)
1=106, 18=1215, 19=1192.
10) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 9.
11) Use Simpson Strong -Tie THJA26 (THJA26 on 1 ply, Right Hand Hip) or equivalent at 7-0-6 from the left end to connect truss(es) to WalterP. Finn PE No.22839
back face of bottom chord. MiTek USA, Inc. FL Cert 6634
12) Use Simpson Strong -Tie THJA26 (THJA26 on 1 ply, Left Hand Hip) or equivalent at 15-3-10 from the left end to connect truss(es) 69D4 Parke East Blvd. Tampa FL 33610
to back face of bottom chord.
13) Fill all nail holes where hanger is in contact with lumber. Date:
14) "NAILED" indicates 3-1 Od (0.148"x3") or 3-12d (0.148"x3.25") toe -nails per NDS guidlines. July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MIrEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. this design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAMSYWI1 AuaIByOffeda, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety intonnotblpvailable from Truss Plate Institute. 218 N. Lee Street. Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482962
75240
GRP
Hip Girder
1
1
Jab Reference (optional)
Chambers 1 russ, Inc., Fort Fierce, FL B.i3us mar 11 zuiu MI I eK Inausines, Inc. i nu Jai o u/:ee:ur Zuiv rage z
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-?LsaFl z5JFNV7ci1mg7HPUOBiBxsbzH93wP4Ygz?BIE
NOTES-
15) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 264 lb down and 421 lb up at 7-0-0, and 264 lb down and 421 lb up at
15-4-0 on top chord. The design/selection of such connection device(s) is the responsibility of others.
16) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-60, 4-6=-60, 6-9=-60, 10-17= 20
Concentrated Loads (lb)
Vert: 4= 217(B) 6=-217(8) 15=-226(B) 13=-37(B) 5= 136(B) 12=-226(B) 20=-136(B) 22= 136(B) 23= 37(B) 24=-37(B)
® WARNING- Verify design parameters and READ NOTES ON TH)S AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek0 connectors. This design Is based only upon parameters shown, and is for an Individual building component, rat
�a
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek7
Is. always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, weANSI/7P11 CualByCrBedd, DSB-89 and SCSI Bulld!ng Component
6904 Parke East Blvd.
Safety lnfonnaSoinvailabie from Truss Plate Institute. 218 N. Lee Street, Suite 312, Mexan dria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply i
YANCY
T14482963
75240
J1
Jack -Open
4
1
Job Reference optional`
Chambers Truss, Inc., Fort Pierce, FL
3-0-0
3-0-0
8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:08 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-UXPySN-j4YVMImHUKXfWyiZPYXJI KaiJla8d4Gz?BID
6x8 11
Scale = 1:10A
2-8-0
04-0
Plate Offsets (X Y)-- f1:0-6-13 0-1-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) -0.00
1 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.09
Vert(CT) -0.01
1 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
2 n/a n/a
BCDL 10.0
Code FBC2017/fP12014
Matrix -MP
Wind(LL) 0.01
1 >999 240
Weight: 15 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 2=-7/Mechanical, 3=-329/Mechanical, 1=571/0-8-0
Max Horz 1=72(LC 12)
Max Uplift 2=-11(LC 3), 3=-329(LC 1), 1=-594(LC 12)
Max Grav 2=6(LC 10), 3=327(LC 12), 1=571(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=oft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2)'This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5j Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2 except (jt=lb)
3=32911=594.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. f 01031201S BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�"
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate This design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional Temporary and permanent bracing
ililiTeW
Is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVW11®ualBy Cdtella, DSB-89 and BCSI BaUd/rlg Component
6904 Parke East Blvd.
Safely IntonnaRonavailable from Truss Plate Institute, 218 N. Lee SYreei, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482964
75240
J 1 P
JACK -OPEN
4
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:08 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-UXPySN-j4YVMImHUKXfWyiZIBXJ_KajJla8d4Gz?BID
-4-0-0 1-0-0
4-0-0 1-0-0
IN 0
ADEQUATE
SUPPORT
REQUIRED.
m
6
Scale = 1:14.0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.00
5
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.09
Vert(CT)
0.00
5
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
1
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MR
Wind(LL)
0.00
5
>999
240
Weight: 10lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. All bearings Mechanical except Qt=length) 5=0-3-8, 1=Mechanical.
(lb) - Max Horz 5=113(LC 12)
Max Uplift All uplift 100 lb or less at joints) 1, 3, 4 except 5=-185(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 3, 4 except 5=314(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-5= 274/352
Structural wood sheathing directly applied or 1-0-0 oc puffins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45fh L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2)=3-11-10 to-0-11-10, Intefior(1)-0-11-10 to 0-11-14 zone;
porch left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3f" This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4 except
Ot=lb) 5=185.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE M11-7473 rev. 10/03&015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown. and is for an individual building component, not
a truss system. Before use, The building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is To prevent buckling of individual truss web and/or chord members only. Additional Temporary and permanent bracing
MO
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/1P11®ualByCdteda, DSB-89 and BCSI Sufiding Component
6904 Parke East Blvd.
Safety fntotmationavallabie from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482965
75240
J3
Jack -Open
4
1
Job Reference (optional)
Chambers I Fuss, Inc., Fort Pierce, FL
5-0-0
8.130 s Mar 11 2018 MITek Industries, Inc. Thu Jul 5 07:22:09 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizi kk3-ykzLgj?LrsdDNwshuEAIVv6YJxg 131 ySXEuBciz?BIC
Scale=1:14.5
4x8 11
2-0-0 2-4-0 , 5-0-0
r 2-0-0 0-4-0 2-8-0
Plate Offsets (X,Y)-- [1:0-6-13,0-1-81
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL,
in
(loc)
I/dell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.31
Vert(LL)
-0.00
1
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.04
Vert(CT)
-0.01
1
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
2
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
Wind(LL)
0.01
1
>999
240
Weight: 25 lb Fr = 20%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x8 SP 240OF 2.0E
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 2=64/Mechanical, 3= 43/Mechanical, 1=374/0-8-0
Max Harz 1=112(LC 12)
Max Uplift 2=-69(LC 12), 3=-43(LC 1), 1=-182(LC 12)
Max Grav 2=64(LC 1), 3=23(LC 12), 1=374(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B-45ft; L=24ft; eaveslft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-11-4 zone; cantilever left
and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2pThis truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3 except (jt=lb)
1=182.
Waiter P. Finn PE No.22839
MiTek USA, Inc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verify design parameter: and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE M11-7473 rev. 10103/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a truss system. Before use, the building designer must vedty the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSOP/I QuatByC18edd, DSB-89 and BCSI Suflding Component
6904 Parke East Blvd.
Safety /ntolmallorpvaliabie from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482966
75240
J3B
Jack -Open
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 Mi I eK Industries, Inc. I hU JUI 5 07:22:10 2018 Page 1
1D:fc6ZRoaxnh?vyJnkAMEaoizlkk3-QwXjt30 cA14_4RtSyh_17ecGL_loUCbmudk89z?BIB
-4-0-0 0-8-1 3-0-0
4-0-0 0-8-1 2-3-15
ADEQUATE
SUPPORT
REQUIRED.
3x6 II
m
Scale = 1:17.8
LOADING (psf)
SPACING-
2-0-0
CS].
DEFL.
in
(loc)
Weil
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.74
Vert(LL)
0.00
5
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.18
Vert(CT)
-0.00
5
>999
240
BCLL 0.0 *
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.01
1
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
Wind(LL)
-0.00
5
>999
240
Weight: 22 lb FT = 20%
LUMBER -
TOP CHORD
2x4 SP No.3
BOT CHORD
2x4 SP No.3 *Except*
4-5: 2x8 SP 240OF 2.0E
OTHERS
2x8 SP 240OF 2.0E
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings Mechanical except (jt=length) 1=Mechanical, 6=0-8-0.
(Ib) - Max Harz 6=157(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) 3 except 1=-111(LC 12), 6=-209(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 3, 4 except 6=326(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 2-6= 284/405
NOTES-
1) Wind: ASCE 7-10; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 2-11-4 zone;
`cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
- will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (t=lb)
1=111,6=209.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Ceti 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10103MIS BEFORE USE.
*�"
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
i.E%t$1
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVI 11 Aualf y Criteria, DS8-09 and SCSI Building Component
6904 Parke East Blvd.
Safety Informallorravailable from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482967
75240
J3P
JACK -OPEN
4
1
Job Reference optional
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:11 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-u6554P1cNTtxcEo3?fCDaKBoGIMOXx31_YNlhbz?BIA
-4-0-0 0-5-5 , 3-0-0
4-0-0 0-5-8 2-6-8
ADEQUATE
SUPPORT
REQUIRED.
Plate Offsets (X,Y}--
7
3x6 I I
-3-11-10 0-5-8 , 3-0-0
3-11-10 0-5-5 2-6-8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.66
Vert(LL)
-0.00
7
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.01
Vert(CT)
-0.00
7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.03
Horz(CT)
-0.00
1
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Wind(LL)
0.00
7
>999
240
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3 *Except*
5-7: 2x8 SP 240OF 2.0E BOT CHORD
WEBS 2x6 SP No.2 *Except'
3-6: 2x4 SP No.3
REACTIONS. All bearings Mechanical except gt=length) 1=Mechanical, 9=0-3-8.
(lb) - Max Horz 9=155(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 4, 5 except 9=-165(LC 12)
Max Grav All reactions 250 lb or less at joint(s)1, 4, 5 except 9=292(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-8=-277/340
5x6 =
Scale=1:17.8
I�
0
PLATES GRIP
MT20 244/190
Weight: 26 lb FT = 20%
Structural wood sheathing directly applied or 3-0-0 oc puffins,
except end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=42psf; BCDL=3:Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
^II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 2-11-4 zone; porch
left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ; This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
- will fit between the bottom chord and any other members.
4) Refer to girder(s)for truss to truss connections.
5) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 4, 5 except
gt=lb) 9=165.
Walter P. Finn PE No32839
MiTek USA, Inc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 101=015 BEFORE USE,
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
�°
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and. to prevent collapse with possible personal injury and property damage. For general guidance regarding me
fabrication, storage, delivery, erection and bracing of trusses and truss systems. se0AM VW119ualfyClBedd, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety MfoaoaAonavailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
IJob Truss Truss Type I I Oty Ply YANCY
T14482968
75240 �J5 Jack -Open 4 1
B
4x8 11
Jab Reference (optional)
8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:11 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizi kk3-u6554P1cNTbccEO3?fCDafBmOIM8XxSl_YNihbz?BIA
7-D-0
7-0-0
7-0-0
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.78
Vert(LL)
-0.02
1
>999
240
TCDL 10.0
Lumber DOL
1.25
BC 0.06
Vert(CT)
-0.02
1
>999
180
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.01
2
n/a
n/a
BCDL 10.0
Code FBC2017/FP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x8 SP 240OF 2.0E
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 2=114/Mechanical, 3=23/Mechanical, 1=418/0-8-0
Max Horz 1=157(LC 12)
Max Uplift 2=-117(LC 12), 3— 2(LC 12), 1=-201(LC 12)
Max Grav 2=114(LC 1), 3=65(LC 3), 1=418(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:18.8
PLATES GRIP
MT20 244/190
Weight: 34 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B-45ft; L=24ft; eave-oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-11-4 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) -This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
61 Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)
2=117,1=201.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING. Verity design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE MIh7473 rev. 10I0 MIS BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAALWWII AaalffyCtBeda, DSB.89 and SCSI SuBdIng Component
6904 Parke East Blvd.
Safety Infotnraflonavallabie from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandra. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482969
75240
J5P
JACK -OPEN
4
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Jul 5 07:22:12 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-MJPTIl1 E8n?oEObGZNjS6Yjzx9i?GOQuDC6rD1 z?Bl9
-4-0-0 0-5-8 , 5-0-0
4-0-0 0-5-8 4-6-8
Scale=1:21.4
ADEQUATE
7
5x6 =
SUPPORT
3x6 11
REQUIRED.
3-11-10
0-5-8
5-0-0
3-11-10
0-5-8
4-6-8
Plate Offsets (X Y)--
(2:0-2-0 0-3-01
LOADING (psi)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.66
Vert(LL)
-0.00
6-7
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.02
Vert(CT)
-0.00
6-7
>999
240
BCLL 0.0 *
Rep Stress Incr
YES
WB 0.02
Horz(CT)
-0.00
1
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Wind(LL)
0.00
7
>999
240
Weight: 38 lb FT = 20%
LUMBER -
TOP CHORD
2x4 SP No.3
BOT CHORD
2x4 SP No.3 *Except*
5-7: 2x8 SP 240OF 2.0E
WEBS
2x6 SP No.2 *Except*
3-6: 2x4 SP No.3
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc pudins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. All bearings Mechanical except Qt=length) 1=Mechanical, 9=0-3-8.
(lb) - Max Horz 9=200(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 4=-137(LC 12), 9= 197(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 4, 5 except 9=354(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 7-9= 287/144, 2-8= 311/381
NOTES-
1) Wind: ASCE 7-10; Vult=17Omph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B--45ft; L=24ft; eave=oft; Cat.
'it; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 4-11-4 zone; porch
left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
' will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Bearing at joint(s) 9 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
4=137, 9=197.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERANCE PAGE M11-7473 rev. 10IM2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
�AT
I V l O e
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabricatlon, storage. delivery. erection and bracing of trusses and truss systems, seeANSI/IPIT ®ualllyCdlelth, DSB-89 and BCSIBuOdLV Component
Tampa, FL, 33610
Safely /nfornraBanovailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Job
Truss
Truss Type
Qty
Ply
YANCY
T74482970
75240
J7
Jack -Open
6
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
i
4-8-9
5x8 11
8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:13 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-gVDrV52sv57frX9S74EhfIGCHYI2?ty2SssOlTz?818
9-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.43
Vert(LL)
0.01
1
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.10
Vert(CT)
0.02
1
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.02
2
n/a
n/a
BCDL 10.0
Code FBC2017/fP12014
Matrix -MS
Wind(LL)
-0.04
1
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x8 SP 240OF 2.0E
WEDGE
Left: 2x4 SP No.3
REACTIONS. (lb/size) 2=162/Mechanical, 3=69/Mechanical, 1=484/0-8-0
Max Horz 1=203(LC 12)
Max Uplift 2= 165(LC 12), 3=-15(1-C 12), 1= 231(LC 12)
Max Grav 2=162(LC 1), 3=119(LC 3), 1=484(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale = 1:22.5
PLATES GRIP
MT20 244/190
Weight: 43 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=3.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 8-11-4 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
27 This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
0) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except at=lb)
2=165,1=231.
Walter P. Finn PE No12839
MiTek USA, Inc. FL Cert 6634
6904 Parke East SWd. Tampa FL 33610
Date:
July 5,2018
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10103l2015 BEFORE USE.
R,
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
at russ system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated"Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
IYl01�k
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, se0ANS&V11 Qual9y CrBeda, DSO-89 and BCSI Building Component
6904 Parke East Blvd.
Safety ►nfennoffenovaliable from Truss Plate institute. 218 N. Lee Meet Suite 312, Alexandria, VA22314.
Tampa, FL 33610
Job
Truss
Truss Type
Oty
Ply
YANCY
r
T14482971
75240
HA
Jack -Open
12
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, I-L ts.i su s mar T i Zu1 a Na i eK inausmes, inc. i nu uw o u/:zz:lw Zino rage i
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-thnDjR3UgOFVThkeholwCzpH 1ylTkIBBgW bylwz?BI7
-4-0-0 0-8-1 , 5-0-0
4-0-0 0-8-1 4-3-15
ADEQUATE
SUPPORT
REQUIRED.
-3-11-9
3x6 11
Scale = 1:21.4
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.82
Vert(LL)
-0.00
4-5
>999
360
MT20 244/190
TCDL 10.0
LumbenDOL
1.25
BC 0.34
Vert(CT)
-0.00
4-5
>999
240
BCLL 0.0 *
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.01
3
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
Wind(LL)
0.00
4,-5
>999
240
Weight: 31 lb FT = 20%
LUMBER -
TOP CHORD
2x4 SP No.3
BOT CHORD
2x4 SP No.3 *Except*
4-5: 2x8 SP 240OF 2.0E
WEBS
2x8 SP 240OF 2.0E
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings Mechanical except Qt=length) 1=Mechanical, 6=0-8-0.
(lb) - Max Horz 6=202(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 1= 104(LC 12), 3=-100(LC 12), 6=-239(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 3, 4 except 6=381(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BOT CHORD 2-6=-335/421
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-1.2psf; BCDL=3.Opsf; h=15ft; B-45ft L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 4-11-4 zone;
cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip
^DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 1, 100 lb uplift at
joint 3 and 239 lb uplift at joint 6.
Walter P. Finn PE No.22839
Wrek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/012015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
8i.
M OTG @C
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, soCANS&VII Quality CrBeda, DSO-89 and SCSI Building Component
6904 Parke East Blvd.
Safety fnfonnotanovdlabte from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
YANCY
T14482972
75240
VP
JACK -OPEN
5
1
Jab Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:14 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-lhnDjR3UgOFVThkeholwCzpJJyNlklbBgWbylwz?BI7
ADEQUATE
SUPPORT
REQUIRED.
0-1-8 min.
4-0-0 '0-5-8' 6-6-8
0-5-B
3x6 11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.67
Vert(LL)
-0.01
6-7
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.05
Vert(CT)
-0.02
6-7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.04
Horz(CT)
-0.00
4
n/a
n/a
BCDL 10.0
Code FBC2017/fP12014
Matrix -MP
Wind(LL)
0.00
7
>999
240
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP No.3 *Except*
5-7: 2x8 SP 240OF 2.0E
WEBS
2x6 SP No.2 *Except*
3-6: 2x4 SP No.3
Scale =1:24.9
0
6
PLATES GRIP
MT20 244/190
Weight: 50 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. All bearings Mechanical except Ot=length) 1=0-1-8, 9=0-3-8.
(lb) - Max Horz 9=245(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) I except 4= 198(LC 12), 9= 232(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 4, 5 except 9=425(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
TOP CHORD 7-9=-348/166, 2-8— 355/412
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
'II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-8 to-0-11-8, Interior(1)-0-11-8 to 6-11-4 zone; porch left
and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for 'truss to truss connections.
5) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except Qt=lb)
4=198, 9=232.
8) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1.
Walter P. Finn PE No.22839
MITek USA, Inc. FL Cart6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED WEK REFERANCE PAGE 114II-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Weie
Is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANS&VII ®ualByCr9aft DSB-a9 and BCSI Building Component
6904 Parke East Blvd.
Satiety /ntormaflonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
YANCY
T14482973
75240
JA
Jack -Open
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:15 2015 Page 1
I D:fc6ZRoaxnh?vyJnkAMEaoiz f kk3-nuLcwn46RiOM5rJrEVH9kALczMheTIRKv9LVgMz?BI6
0-7-4 2-11-3
I , 2-3-15
3x4
4.50
3xs 11
Scale = 1:17.8
i 0-7-4
0-77
2-11-3
2-3-15
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
1/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.17
Vert(LL)
-0.00
5
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.15
Vert(CT)
-0.00
5
>999
240
BCLL 0.0 *
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MR
Wihd(LL)
0.00
6
>999
240
Weight: 15 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP N0.3 *Except` BOT CHORD
4-5: 2x8 SP 240OF 2.0E
REACTIONS. All bearings 0-7-3 except Qt=length) 3=Mechanical, 4=Mechanical.
(lb) - Max Harz 1=65(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 3, 1 except 6=-146(LC 12)
Max Grav All reactions 250 lb or less at joints) 1, 3, 6, 4
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 2-6=-161/302
Structural wood sheathing directly applied or 2-11-3 oc purlins.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3r* This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 1 except
at=lb) 6=146.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity deslgn parameters and READ NOTES ON THIS AND INCLUDED mn EK REFERANCE PAGE M11-7473 rev. 10/03I2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
�,
Da
a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
prevent
is always required for stability and to prevent collapse vAth possible personal injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAIlfSVW11 GualtlyCi feria, DS8-89 and BCSI BUlfd/ng Component
Tampa, FL 33610
Safety Infonoaffonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Job
Truss
Truss Type
Oty
Ply
YANCY
T14482974
75240
JA1
Jack -Open
3
1
Jab Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 Mtl ek Industries, Inc. I hu Jul 5 07:22:16 2018 Page 1
I D:fc6ZRoaxnh?vyJnkAMEaoiz 1 kk3-F4u_864kCOW Di?u 1 oDoOHOug2m 1 MCChU8p42Moz?BI5
-4-0-13 0-11-3
4-0-13 0-1 1-3
Scale=1:14.0
ADEQUATE
SUPPORT
REQUIRED.
0-1-8 min.
Plate Offsets (X Y)--
f2:0-0-0 0-1-01
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.00
7
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.19
Vert(CT)
0.00
7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
1
n/a
n/a
BCDL 10.0
Code FBC2017TFP12014
Matrix -MP
Wind(LL)
-0.00
7
>999
240
Weight: 9 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3 BOT CHORD
REACTIONS. All bearings Mechanical except at=length) 1=0-0-12, 2=0-7-3.
(lb) - Max Horz 2=113(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1, 3, 4 except 2=-203(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 3, 4 except 2=410(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Structural wood sheathing directly applied or 0-11-3 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -4-0-7 to-1-0-7, Interior(1) -1-0-7 to 0-11-1 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3).* This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)1, 3, 4 except
' (jt=lb) 2=203.
7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 114II-7473 rev. 10/0312015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component not
a Truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
�y
WOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSW11 GualltyCrlleda, DSO-89 and BCSI SuBding Component
6904 Parke East Blvd.
Safely Infonnati on3vallabie from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
YANCY
T14482975
75240
JA5
Jack -Open
1
1
Job Reference optional
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Jul 5 07:22:17 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-jGSMLS5NzJe4K9TDMwJdpbRIVANnxdxdNTgcuFz?B14
2-0-0 0-5-8 4-6-0 5-0-0
2-0-0 0-5-8 4-0-8 0-6-0
Scale = 1:16.4
10 3x6 11 3x6 11
LOADING, (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Lid
TCLL 20.0
Plate Grip DOL
1.25
TC 1.00
Vert(LL)
-0.02
10
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.17
Vert(CT)
-0.05
10
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.13
Horz(CT)
-0.01
6
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL)
0.08
10
>726
240
LUMBER -
TOP CHORD
2x4 SP No.3
BOT CHORD
2x4 SP No.3 *Except*
8-10: 2x8 SP 240OF 2.0E
WEBS
2x4 SP No.3
REACTIONS. (lb/size) 5=168/Mechanical, 6=5/Mechanical, 2=349/0-3-8
Max Harz 2=182(LC 12)
Max Uplift 5=-98(LC 12), 2= 297(LC 12)
Max Grav 5=169(LC 17), 6=1 O(LC 3), 2=349(LC 1)
FORCES. (lb) -Max. Comp./Max Ten. -All forces 250 (lb) or less except when shown.
WEBS 3-11=-160/427
PLATES GRIP
MT20 244/190
Weight: 29 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 8-9.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft B=45ft; L=24ft; eave=4ft Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-0-0 to 0-10-12, Interior(1) 0-10-12 to 4-11-4 zone; cantilever
'left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 5 except (jt=lb)
2=297.
Walter P. Finn PE No.22838
MiTek USA, Inc. FL Cart 6634
6804 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 11111-7473 rev. 101031MIS BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
VIO W
MOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUIPII AUallty CtBetlat DSB-89 and BCS►BUBding Component
6904 Parke East Blvd.
Safety informatlotl3vailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type I
Qty
Ply
YANCY
T74482976
75240
JA7
Jack -Open
2
1
Job Reference:tionai'
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:18 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-BTOkYo6?jdnWJ2PwdgsMpzymZjBg5Knb7Z9Rhz?BI3
-2-0-0 0-5-8 , 4-6-0 5-4-1 7-0-0
2-0-0 +0-5-8 4-0-8 0-10-1 1-7-15
2
3x4 =
13 12 11 0
3x6 11 3x6 11 3x6 11
Scale = 1:21.7
Plate Offsets (X Y)--
f2:0-1-7,0-1-81, f3:0-7-8,0-1-81, (3:0-1-12,0-0-111, fl4:0-0-0;0-1-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL:
in
(loc)
I/dell
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.83
Vert(LL)
-0.02
11
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.16
Vert(CT)
-0.04
11
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(CT)
-0.01
7
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Wind(LL)
0.05
10
>999
240
Weight: 41 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3 "Except'
11-13,7-8: 2x8 SP 240OF 2.0E
WEBS 2x4 SP No.3
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings Mechanical except Qt=length) 9=0-8-0, 2=0-3-8.
(lb) - Max Harz 2=227(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 6 except 9=-231(LC 12), 2=-275(LC 12)
Max Grav All reactions 250 lb or less at joints) 6, 7 except 9=407(LC 17), 2=338(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 5-9=-491/549
WEBS 3-14=0/372
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B--45ft; L=24ft; eave=4ft; Cat.
'ql; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-0-0 to 0-10-12, Interior(1) 0-10-12 to 6-11-4 zone; cantilever
left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
- will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except 611=1b)
9=231, 2=275.
WalterP. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mr1-7473 rev. 1010312015 BEFORE USE.
(I�
Design valid for use only Win MTTek® connectors. This design is based only upon parameters shown, and is for an Individual building component,. not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
`j
MiTek
Is always required for stability and toprevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSLI71 r Quality Ciffedd, DSO-89 and BCS1 Bui eling Component
6904 Parke East Blvd.
Safety IntonnaBonovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
YANCY
T14482977
75240
JB
Jack -Open
1
1
Job Reference 1ional)
Chambers Truss, Inc., Fort Pierce, FL
KzZiB
0-11-3
0-11-3
8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:18 2018 Page 1
I D:fc6ZRoaxnh?vyJnkAMEaofzt kk3-BTOkYo6?jdmxyJ2PwdgsMpz90ZIFg6Bnb7Z9Rhz?BI3
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.03
Vert(LL)
-0.00
6
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.03
Vert(CT)
-0.00
6
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
2
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Wind(LL)
0.00
6
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 1=37/0-7-3, 2=24/Mechanical, 3=13/Mechanical
Max Horz 1=21(LC 12)
Max Uplift 1=-12(LC 12), 2= 24(LC 12), 3=-6(LC 12)
Max Grav 1=37(LC 1), 2=24(LC 1), 3=17(LC 3)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:7.2
PLATES GRIP
MT20 244/190
Weight: 3 Ib , FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 0-11-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 13=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and
forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
47 Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2, 3.
Walter P. Finn PE No,22839
MiTek USA, Inc. FL Cori 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Vedly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 1010312015 BEFORE USE
Design valid for use only with MiTek® connectors. this design Is based only upon parameters shown, and is for an Individual building component not
�'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
Is always required for stability and To prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, dellvery, erection and bracing of trusses and truss systems, seeANS&VI r 9ualffyCrCorb, DSB-89 and BCSI BuOdtng Component
6904 Parke East Blvd.
Satefylntormatlomvallabie from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type I
City
Ply
YANCY
T14482978
75240
JB1
Jack -Open
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:19 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizi kk3-ffa6m87dUxuoZSdcTLL5vOW7W z4?PZRwgnJjz7z?BI2
-2-0-0 1-0-0
2-0-0 1-0-0
Scale =1:7.5
11-0-0-0-0 i
Plate Offsets (X,Y)-- (2:0-0-9,0-0-01
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.83
Vert(LL) 0.00
5 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.13
Vert(CT) 0.00
5 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017/-FP12014
Matrix -MP
Wind(LL) -0.00
5 >999 240
Weight: 6 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 ocpudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=-26/Mechanical, 2=281/0-3-8, 4=-56/Mechanical
Max Horz 2=92(LC 12)
Max Uplift 3= 26(LC 1), 2=-381(LC 12), 4=-56(LC 1)
Max Grav 3=59(LC 12), 2=281(LC 1), 4=108(LC 12)
FORCES. (lb) - Max. Comp./Max Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave--#t; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and
forces & MWFRS for reactions shown; Lumber DOLr1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
'will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Ot=lb)
2=381.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSV7P119ualify CiBeito, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety /ntormatlonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
YANCY
T14482979
75240
JB3
Jack -Open
2
1
Job Reference (optional)
L,namoers L russ, mc., ron coerce, rL
2-0-0
15.1:1U S IMF I I LUI0 IVII I eK IrMUSLLIBS, In(;. I nU JUI O W;ee;eu eU t o Page I
ID:fc6ZRoaxnh?vyJnkAM Eaoizl kk3-7r8VzU7FFEOfBcCo 12sKRE31GNOR8?r43R2GVaz? Bi 1
0-5-8 3-0-0
62x3 II
7
Scale = 1:14.0
Plate Offsets (X Y)--
(2:0-1-1 Edgej f3:0-7-8 0-1-91 f3:0-1-12 0-0-111 fB:0-0-0 0-1-121
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.83
Vert(LL)
-0.00
7
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.18
Vert(CT)
-0.01
7
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(CT)
-0.01
5
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL)
-0.01
7
>999
240
Weight: 14 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=59/Mechanical, 5=19/Mechanical, 2=285/0-3-8
Max Horz 2=136(LC 12)
Max Uplift 4=-39(LC 9), 2= 286(LC 12)
Max Grav 4=65(LC 17), 5=39(LC 3), 2=285(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 3-8= 39/398
BRACING-
TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc puriins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-0-0 to 0-10-12, Interior(1) 0-10-12 to 2-11-4 zone; cantilever
left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
S) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Ot=lb)
2=286.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED M17EK REFERANCE PAGE M11-7473 rev. 10/03I2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component not
�•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage. delivery, erection and bracing of trusses and truss systems, seeANS&7P/1 Qualify Cdteda, DSB-69 and BCSI SuHd/ng Component
6904 Parke East Blvd.
Safety /ntolmotlonavailable from Truss Plate institute. 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
YANCY
T14482980I
75240
JB5
Jack -Open
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Jul 5 07:22:21 2018 Page 1
1 D:fc6ZRoaxnh?vyJnkAMEaoizl kk3-b2itBg8tOY8Wpnin_bmNZ_RbYSnIStSgDR5op 1 Oz?BIO
3-0-0 4-0-13 7-0-0
3-0-0 1-0-13 2-11-3
Scale=1:19.5
3x6 11 3x6 I
7 6
2-0-0 3-0-0 4-0-13
7-0-0
2-0-0 1-0-0 1-0-13
2-11-3
Plate Offsets (X Y)-- (3:0-3-12 0-0-61
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.55
Vert(LL) -0.02 5 >999 360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.13
Vert(CT) -0.05 5 >748 240
BCLL 0.0
Rep Stress Incr YES
WB 0.07
Horz(CT) 0.01 3 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
Wind(LL) 0.02 5 >999 240
Weight: 35 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins.
BOT CHORD 2x8 SP 240OF 2.0E *Except*
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
3-6: 2x4 SP No.3
WEBS 2x4 SP No.3
REACTIONS. All bearings 2-0-13 except Qt=length) 4=Mechanical, 3=Mechanical.
(lb) - Max Horz 7=163(LC 12)
Max Uplift All uplift 100 lb or less at joints) 4 except 6=-375(LC 1), 3=-132(LC 12), 7=-537(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 4 except 6=291(LC 12), 3=342(LC 3), 7=532(LC 1)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 1-7=-104/263
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-11-4 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
41 Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
6=375, 3=132, 7=537.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
Q WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE 11,1II-7473 rev. 10/031201S BEFORE USE.
Design valid for use only with mucke connectors. This design Is based only upon parameters shown, and Is for an Indivdual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
M lW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSMII Qualify Cdfeda, DSB-89 and SCSI BuHdfng Component
6904 Parke East Blvd.
Safety InfomtaHonavallable from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482981
75240
JG3
Jack -Open
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
4-0-13
ADEQUATE
SUPPORT
REQUIRED.
8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:21 2018 Page 1
ID:fcBZRoaxnh?vyJnkAMEaoizl kk3-b2itBg8tOY8Wpmn_bmNZ_RbYMnmCtTwDH5op 10z?BI0
2-11-3
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.56 ,
Vert(LL)
-0.00
7
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.01
Vert(CT)
-0.00
7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
1
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Wind(LL)
0.00
7
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x8 SP 240OF 2.0E
REACTIONS. All bearings Mechanical except Qt=length) 1=Mechanical, 2=0-7-3.
(lb) - Max Horz 2=157(LC 12)
Max Uplift All uplift 100lb or less atjoint(s) 1, 3 except 2= 182(LC 12)
Max Grav All reactions 250 lb or less at joints) 1, 3, 4 except 2=390(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale =1:17.7
PLATES GRIP
MT20 244/190
Weight: 20 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-11-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -4-0-7 to-1-0-7, Interior(1) -1-0-7 to 2-10-7 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4?Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except Qt=lb)
2=182.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery. erection and bracing of trusses and truss systems, seeANSWI1Qualify CrBeffa, DSB-89 and SCSI BUgdfng Component
6904 Parke East Blvd.
Safety Intonnallonavailabie from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
City
Ply
YANCY
T14482982
75240
JG7
Jack -Open
3
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07.22:22 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizf kk3-3EGFOA9VnsGNQwMB9TvoWfBizB6lcvAM WIXNaSz?Bi?
ADEQUATE
SUPPORT
REQUIRED.
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.57
Vert(LL)
-0.00
7
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.06
Vert(CT)
-0.01
4-7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017[TP]2014
Matrix -MP
Wind(LL)
0.01
4-7
>999
240
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x8 SP 240OF 2.0E
REACTIONS. All.bearings Mechanical except Ot=length) 1=0-1-0, 2=0-7-3.
(lb) - Max Horz 2=202(LC 12)
Max Uplift All uplift 100 lb or less atjoint(s) 1, 3,4 except 2=-208(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 3, 4 except 2=453(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale=1:21.3
PLATES GRIP
MT20 244/190
Weight: 30 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-11-3 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -4-0-5 to-1-0-5, Interior(1) -1-0-5 to 4-10-7 zone; cantilever left
and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4f Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4 except
at=lb) 2=208.
7) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNINNG - Verity design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANS&VII AualBy Crlteda, DS849 and BCSI BaUd/ng Component
6904 Parke East Blvd.
Safety /nfonnaBOnavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482983
75240
KJ7
Diagonal Hip Girder
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 Mfrek Industries, Inc. I hu Jul 5 07:22:24 2018 Page 1
I D:fc6ZRoaxnh?vyJnkAMEaoizl kk3-OcN?psBn1JTW 5gEVZGuxGb4D7Y_m14mIf_30UdLz?BHz
3-3-4 6-8-2 7-9-14 12-8-0
3-3-4 3-4-15 1-1-11 4-10-2
4x8 118 „ 5
Special NAILED NAILED
Sx6 =
2-9-9
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 6.24
Vert(LL)
0.02
7
>999
240
TCDL 10.0
Lumber DOL
1.25
BC 0.18
Vert(CT)
-0.02
6-7
>999
240
BCLL 0.0 '
Rep Stress Incr
NO
WB 0.25
Horz(CT)
-0.01
4
n/a
n/a
BCDL 10.0
Code FBC2017fTP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x8 SP 240OF 2.0E
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=140/Mechanical, 8=251/0-11-5, 6=144/Mechanical
Max Horz 8=208(LC 8)
Max Uplift 4=-140(LC 8), 8=-929(LC 8), 6=-217(LC 5)
Max Grav 4=140(LC 1), 8=878(LC 27), 6=247(LC 28)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 1-2= 554/484, 2-3=-534/483
BOT CHORD 1 -8=458/567, 7-8= 471/458, 6-7=-471/458
WEBS 3-7=-395/329, 3-6=-496/509
PLATES GRIP
MT20 244/190
Weight: 69 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except:
10-0-0 oc bracing: 5-6.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave-lft; Cat.
*11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
k) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
4=140, 8=929, 6=217.
6) Use USP SKH26L (With 16d nails into Girder & NA9D nails into Truss) or equivalent at 4-4-0 from the left end to connect truss(es) to
front face of bottom chord, skewed 45.0 deg.to the left, sloping 0.0 deg. down.
7) Fill all nail holes where hanger is in contact with lumber.
8) "NAILED" indicates 3-1 Od (0.148"x3") or 2-12d (0.148"x3.25") toe -nails per NDS guidlines.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-4=-60, 1-5=-20
Concentrated Loads (lb)
Vert: 11=68(F=34, B=34) 13=-58(F= 29, B=-29) 14=381(F=191, B=191) 15=77(F=39, B=39) 16=6(F=3, B=3)
Walter P. Finn PE No12839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010"IS BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Indlvdual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Ni, iTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSYWIT QualllyCAfeda, DSB-89 and BCSI BuIlding Component
6904 Parke East Blvd.
Safety Infonnahbnovallabte from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482984
75240
KJ7G
Diagonal Hip Girder
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MITek Industries, Inc. Thu Jul 5 07:22:25 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-Upx008804neylN4mgcSV8Hm1106XpD?pCjni 19nz?BHy
3-3-4 6-8-2 7-9-14 12-8-0
3-3-4 3-4-15 1-1-11 4-10-2
Special
2-9-9 . 33-4
NAILED
LOADING (pst)
SPACING-
2-0-0
CSI.
DEFL,
in
(loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.24
Vert(LL)
0.02
7
>999
240
TCDL 10.0
Lumber DOL
1.25
BC 0.18
Vert(CT)
-0.02
6-7
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.25
Horz(CT)
-0.01
4
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x8 SP 240OF 2.0E
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=140/Mechanical, 8=251/0-11-5, 6=144/Mechanical
Max Harz 8=208(LC 24)
Max Uplift 4=-140(LC 8), 8=-929(LC 8), 6=-217(LC 5)
Max Grav 4=140(LC 1), 8=878(LC 27), 6=247(LC 28)
FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-554/484, 2-3=-534/483
BOT CHORD 1-8=-458/567, 7-8= 471/458, 6-7=-471/458
WEBS 3-7=-395/329, 3-6=-496/509
:21.0
NAILED
5x6 =
12-8-0
4-10-2
PLATES GRIP
MT20 244/190
Weight: 69 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except:
10-0-0 oc bracing: 5-6.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL--4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb)
4=140, 8=929, 6=217.
6) Use USP SKH26L (With 16d nails into Girder & NA9D nails into Truss) or equivalent at 4-4-0 from the left end to connect truss(es) to
front face of bottom chord, skewed 45.0 deg.to the left, sloping 0.0 d'eg, down.
7) Fill all nail holes where hanger is in contact with lumber.
8) "NAILED" indicates 3-1 Od (0.148"x3") or 2-12d (0.148"x3.25) toe -nails per NDS guidlines.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-60, 1-5= 20
Concentrated Loads (lb)
Vert: 11=68(F=34, B=34) 13=-58(F=-29, B=-29) 14=381(F=191, B=191) 15=77(F=39, B=39) 16=6(F=3, B=3)
Wafter P. Finn PE No.22839
MITek USA, Inc. FL Cert 6034
69D4 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MIrEK REFERANCE PAGE MII-7473 rev. 1010=015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek7
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage. delivery. erection and bracing of trusses and truss systems. socAAWRP11 QualityCiBedd, DSB.89 and SCSI Sulld/ng Component
6904 Parke East Blvd.
Safely Informanonavailabte from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA22314.
Tampa, FL 33610
Job
Truss Truss Type
city
Ply
YANCY
T14482985
75240
KJA Diagonal Hip Girder
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:26 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizt kk3-y?VmEXCOr4movXfyOJzkhVJRaoSrYgRNVaiDz?BHx
1-0-1 1-7-14 4-2-4 , 7-0-2
1-0-1 0-7-13 2-6-6 2-9-14
Scale=1:23.7
0
0
34 11
NAILED
NAILED
1-7-14 4-2-4
1-7-14 2-6-6
34 11
NAILED
NAILED
7-0-2
2-9-14
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.33
Vert(LL) -0.07
7 >999 360
MT20
244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.11
Vert(CT) -0.09
7 >940 240
BCLL 0.0
Rep Stress Incr NO
WB 0.10
Horz(CT) 0.08
5 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
Wind(LL) 0.10
7 >807 240
Weight: 35lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0
oc purlins.
BOT CHORD 2x4 SP M 30 *Except`
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing,
Except:
2-7: 2x4 SP No.3, 5-7: 2x8 SP 240OF 2.0E
6-0-0 oc bracing: 1-8.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1=185/0-10-15, 4=63/Mechanical, 5=178/Mechanical
Max Harz 1=112(LC 8)
Max Uplift 1= 167(LC 8), 4= 65(LC 24), 5=-136(LC 8)
Max Grav 1=241(LC 28), 4=73(LC 17), 5=198(LC 28)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BOT CHORD 2-8= 298/319
WEBS 3-6=-318/327
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2rThis truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 36-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
1=167,5=136.
6) "NAILED" indicates 3-1Od (0.148"x3") or 2-12d (0. 1 48"x3.25") toe -nails per NDS guidlines.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-60, 8-9=-20, 5-7= 20
Concentrated Loads (lb)
Vert: 8=58(F=-4, B=61) 2=61(B) 6=1 O(F=O, B=10)
Walter P. Finn PE No.21839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MrTEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a Truss system. Before use, the building designer must verify The applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAALWMll Aaallly Cdleda, DSO-89 and BCSI Bugdbv Component
6904 Parke East Blvd.
Safety lnfonnallonavallabie from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482986
75240
KJA7
Diagonal Hip Girder
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07.,22:27 2018 Page 1
I D:fc6ZRoaxnh?vyJnkAMEaoizl kk3-QB38RtDecOufXhE8xOUzDircaCmnH2S6g 1 F8Egz?BHw
0-7.12
-2-9-15 0-510 Q-11.4 3-5-5 , 6-2-14 , 6-10-12 , 7.6-111 8-6-9 9-10-1
2-9-15 mluo W. 2-6-1 2-9-9 0-7.14 0-7-14 1-0-0 1-3-8
0.2-2
Scale=1:26.4
3x5 =
17 16
6x8 =
Special
Special
uno „
15 NAILED 14 10
3x6 11 NAILED Sx6 = 3x6 II
7-0-2
,0-7-1z 6-2-14 ,s-10-12„7-6-10, s-10-
0-7-12 2-9-9 2-9-9 0-7-14 0-6-6 2-3-7
0-1-6
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.38
Vert(LL)
0.02
17
>999
240
TCDL 10.0
Lumber DOL
1.25
BC 0.20
Vert(CT)
-0.02
17
>999
180
BCLL 0.0
Rep Stress Incr
NO
WB 0.57
Horz(CT)
0.01
9
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x8 SP 240OF 2.OE `Except`
5-14,7-10: 2x4 SP No.3, 2-18: 2x4 SP M 30
WEBS 2x4SPNo.3
PLATES GRIP
MT20 244/190
Weight: 63 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
6-0-0 oc bracing: 12-13,11-12.
REACTIONS. All bearings Mechanical except (jt=length) 2=0-4-9, 12=0-11-5.
(lb) - Max Harz 2=226(LC 24)
Max Uplift All uplift 100 lb or less at joint(s) 8, 9 except 2= 425(LC 8), 12=-273(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 8, 9 except 2=433(LC 28), 12=523(LC 28)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-863/52, 3-4=-382/0
BOT CHORD 15-16=-56/269, 14-15= 56/269, 2-18=-139/668
WEBS 3-18=-135/369
NOTES-
1)*Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
' will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 9 except Qt=lb)
2=425,12=273.
6) "NAILED" indicates 3-1 Od (0.148"x3") or 2-12d (0.148"x3.25") toe -nails per NDS guidlines.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 58 lb down and 55 lb up at
1-4-8, and 58 lb down and 55 lb up at 1-4-8 on bottom chord. The designtselection of such connection device(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pit)
Vert: 1-8=-60, 14-17=-20, 11-13=-20, 9-10— 20, 18-19= 20
Concentrated Loads (lb)
Vert: 16=69(F=35, B-35) 6= 86(F=-83, B=-3)
Wafter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M1I-7473 rev. 101 201S BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
��
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
n�
IM iT e
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUIP/r Qua/ByCdledo, DS8.69 and SCSI BuBding Component
6904 Parke East Blvd.
Safety ►n/ormallonovallable from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type :
Qty
Ply
YANCY
T14482987
75240
KJG7
Diagonal Hip Girder
1
1
Job Reference o tionet
Chambers Truss, Inc., Fort Pierce, FL 8.130 6 Mar 11 2018 MI I eK industries, Inc. Thu dui b 07:22:28 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-uOdW fDEGNiOW9rpKVk?CmwOnPbBaOdnFvh_hm6z?BHv
-5-9.0 3-5-5 6-10-15
5-9-0 3-5-5 3-5-11
Scale=1:25.2
NAILED o
Io
•
NAILED
3.18
12
2x3 II 10
NAILED
3
NAILED
v
0
N
Li
6 11
NAILED
3x6 II NAILED 5
i
4x5 =
NAILED
NAILED
`o
0 0
ADEQUATE
SUPPORT
REQUIRED.
6-10-15 _
r
6-10-15
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/defl Ud
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC 0.38
Vert(LL) -0.01
6
>999 360
MT20 244/190
TCDL
10.0
Lumber DOL
1.25
BC 0.10
Vert(CT) 0.02
6
>999 180
BCLL
0.0
Rep Stress Incr
NO
WB 0.06
Horz(CT) -0.00
1
n/a n/a
BCDL
10.0
Code FBC2017[FP12014
Matrix -MP
Wind(LL) -0.01
6
>999 240
Weight: 42 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x8 SP 240OF 2.0E BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. All bearings Mechanical except at=length) 1=Mechanical, 2=0-9-13.
(lb) - Max Horz 2=202(LC 24)
Max Uplift All uplift 100 lb or less atjoint(s) 4, 5 except 1=-112(LC 24), 2=-360(LC 8)
Max Grav All reactions 250 lb or less at joint(s)1, 4, 5 except 2=554(LC 28)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Structural wood sheathing directly applied or 6-0-0 oc pudins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft eave-oft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4PRefer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 5 except Qt=lb)
1=112,2=360.
6) "NAILED" indicates 3-1 Od (0.148"x3") or 2-12d (0.148"x3.25") toe -nails per NDS guidlines.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-8=-81, 4-8=-60, 5-7=-20
Concentrated Loads (lb)
Vert: 8=122(F=61, B=61) 9=123(F=61, B=61) 11= 3(F=-1, B=-1)
Welter P. Finn PE No.22839
WTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111II-7473 rev. 10103&015 BEFORE USE.
Design valid for use only with MITekO connectors. This design Is based only upon parameters shown, and is for an Individual building component not
�"
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse wlth possible personal Injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSVW11 GaalBy Cdlafta, OS&89 and BCSI BUllding Component
6904 Parke East Blvd.
Safety twonnottonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33510
Job
Truss
Truss Type r
Oly
Ply
YANCY
T14482988
75240
KJP
DIAGONAL HIP GIRDER
2
1
:Job
Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
I�
ADEQUATE
SUPPORT
REQUIRED.
b.1JU s Mar 11 ZU16 Mil eK inaUstrles, inc. i nu Jui o uI:ZZ:JV zu is r-dye r
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-gmIH4vFWvJGE09zjd92grLT6EPj?U W XYM?Tor_z?BHt
0-7-13
-5-7-14 3-1 5-1-3 9-10-1
5-7-14 -5-1 4-5-6 4-8-14
0-2-2 i R c
8 NAILED NAILED 7 NAILED
3x6 II NAILED4x4 = NAILED
�i!F11B�7
Scale=1:30.6
0
Io T
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.42
Vert(LL) 0.11
7 >999 240
MT20
244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.55
Vert(CT) -0.10
7 >999 240
MT18HS
244/190
BCLL 0.0 *
Rep Stress Incr
NO
WB 0.10
Horz(CT) -0.02
5 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 66 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0
oc purlins.
BOT CHORD 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
6-8: 2x8 SP 240OF 2.0E
WEBS 2x4 SID No.3 *Except*
2-9: 2x8 SP 240OF 2.0E
REACTIONS. All bearings Mechanical except Qt=length) 1=Mechanical, 9=0-4-9.
(lb) - Max Horz 9=247(LC 8)
Max Uplift All uplift 100 lb or less at joint(s) except 5=-165(LC 8), 6=-157(LC 8), 1=-138(LC 24), 9=-425(LC 8)
Max Grav All reactions 250 lb or less at joint(s) 5, 6, 1 except 9=536(LC 28)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BOT CHORD 2-9— 369/218
WEBS 4-7=-336/352, 2-7= 49/252
NOTES-
1 f Wind: ASCE 7-10; Vult=l7omph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) All plates are MT20 plates unless otherwise indicated.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 165 lb uplift at joint 5, 157 lb uplift at
joint 6, 138 lb uplift at joint 1 and 425 lb uplift at joint 9.
8) "NAILED" indicates 3-1 Od (0.148"xX) or 2-12d (0.148"x3.25") toe -nails per NDS guidlines.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-5=-60, 6-8= 20
Concentrated Loads (lb) Walter P. Finn PE No.22839
Vert: 10=105(F=52, B=52) 12=102(F=-51, B=-51) 13=62(F=31, B=31) 15=-5(F=-3, B=-3) MiTekUSA, Inc. FLCart 6634
6804 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10103,2015 BEFORE USE,
Design valid for use only with MITek® cgnnectors. This design is based only upon parameters shown, and Is for an Individual building component, not
�'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
i1NCTW
MOW
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/IPII CualBy Ciflerla, DS8-89 and SCSI BuIlding Component
6904 Parke East Blvd.
Safety fnfaanallonovaliabie from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type ,
Qty
Ply
YANCY
T14482989
75240
P
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:31 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-JzlfHFG9fdP501YVASZvOY01?p2LDuyhbfDLNRz?BHs
-4-0-0 -8-12 9-0-0 13-4-0 20-0-10 21-6-2
4-40 5- 4-3-4 4-3-4 4-4-0 6-6-10 1-5-6
4x4 =
21
5x6 =
Scale = 1:46.6
SUPPORT 3x5 II 4x5 =
REQUIRED.
3x6 II 6x8 = 45 = 3x5 II
21-58
-4-0-13 ¢5-8 9-0-0
, 13-4-0 _ 20-0-10 20-8-1a
211 -2
%12
4-0-13 -5-8 4-3-0 4-3-4
4-4-0 6-8-10 b-&3'
0-Oi10
0-8-11
Plate Offsets (X Y)-- f5:0-3-0 0-2-61 f9:0-5-8 0-3-01
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) I/defl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.35
Vert(LL) -0.03 13-14 >999 360
MT20
244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.60
Vert(CT) -0.05 13-14 >999 240
BCLL 0.0
Rep Stress lncr YES
WB 0.41
Horz(CT) -0.01 1 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Wind(LL) 0.04 13-14 >999 240
Weight: 161 Ib
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x8 SP 240OF 2.0E *Except*
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
2-15,6-10: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except*
2-16: 2x6 SP No.2
REACTIONS. (lb/size) 1=103/0-1-0, 7=0/1-0-3, 16=977/0-3-8, 8=867/0-3-8
Max Horz 16=134(LC 11)
Max Uplift 1=-101(LC 12), 16=-599(LC 12), 8=-543(LC 12)
Max Grav 1=103(LC 1), 16=996(LC 17), 8=867(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-963/668, 3-4=-963/773, 4-5=-8677786, 5-6=-7671744, 6-7=-433/297
BOT CHORD 2-16=-9217718, 13-14= 566/872, 11-13=-564/875, 6-9= 423/555, 8-9= 252/364,
7-8=-302/418
WEBS 2-14= 575/940, 3-14=-253/339, 9-11=-4697779, 5-9= 384/78
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft B=45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-8 to-0-11-8, Interior(1)-0-11-8 to 9-0-0, Exterior(2) 9-0-0
to 13-4-0, Intedor(1) 17-6-15 to 21-6-2 zone; porch left and right exposed;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Bearing at joint(s) 16 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 1.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 101 Ib uplift at joint 1, 599 Ib uplift at
joint 16 and 543 Ib uplift at joint 8.
9) Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) 1.
Waiter P. Finn PE No.22839
MIT& USA, Inc. FL God 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 101OM15 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
6ViiTeW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSVIPII QualityCiBorld DSB-89 and BCSI SuUding Component
Tampa, FL 33610
Safety Infotlnaflonavaliabie from Truss Plate Institute, 218 N. Lee Sheet. Suite 312, Alexandria, VA 22314.
Job
Truss
Truss Type
Qty
Ply
YANCY
T74482990
75240
P1
HIP
1
1
Job Reference (optional)
Chambers I russ, Inc., Fort fierce, FL ts.i iu s mar 11 LUl is ivii i eK mausines, Inc. I nu jui b u/:LL:JL Lu1 o rage i
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-n9s1 UbHnQwXydS66ka48wmYVMDRsyH2rpJyvvtz?BHr
11d-0
-4-0-0 0-5-6 5-8-12 i 11-oA 11r2-0 16-7-1 i 16-1-12
r 4-0-D 5- 5-3-4 5-3-4 5-3-Y 1-611
0-2-0
Scale = I AO.7
5xB =
4.50 12
ADEQUATE 1b 14
1L I
SUPPORT 5x6= 3x6 II
6x8 =
3x6 II 5x6 =
REQUIRED.
11-4-0
-3-11-10 p-5-6 5.8-12
it-"
11r2-0 16-7-1 d7-2-618-1-12i
3-11-1 r 5- S-3d
5-3-4
0.- 5-3-1 �0.7-7� 0-11d
0-2-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.25
Vert(LL) -0.04
14 >999 360
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.39
Vert(CT) -0.08
14 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.68
Horz(CT) -0.01
1 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Wind(LL) 0.07
14 >999 240
Weight: 134lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puriins,
BOT CHORD 2x8 SP 240OF 2.0E *Except"
except end verticals.
2-15: 2x4 SP No.3, 6-11: 2x6 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
WEBS 2x4 SP No.3
6-0-0 oc bracing: 2-16.
OTHERS 2x6 SP No.2
REACTIONS. All bearings 0-3-8 except (jt=length) 8=1-2-12, 1=Mechanical.
(lb) - Max Horz 16=188(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 1 except 8= 230(LC 18), 16=-510(LC
12), 9= 559(LC 12)
Max Grav All reactions 250 Ito or less at joint(s) 8, 1 except 16=836(LC 17), 9=915(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 4-5=-612/504
BOT CHORD 15-16=-278/504, 2-16=-346/352, 14-15=-374/564, 12-14=-365/559, 11-12=
365/559,
10-11=-215/451, 6-10=-286/369
WEBS 4-15=-608/308, 4-14=-176/309, 5-11= 670/405, 5-12= 1921456
NbTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=241t; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 11-2-0, Exterior(2)
11-2-0 to 15-4-15 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 36-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except Qt=lb)
8=230, 16=510, 9=559.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only Win MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage. delivery, erection and bracing of trusses and truss systems, seeANSUMI Qualify Cdteda, DSB-89 and BCSI Balling Component
6904 Parke East Blvd.
Safety infonnationovailabie from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482991
75240
P2
ROOF SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:33 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-FLQPiwiPBEfpFchllHbNTz5bxckNhrL_2ziSSJZ?BHq
11-2-0 i 13-1-8 14-8-3
4-0-0 -5- 5-4-4 5-4-4 - 1-11-B 1-6-11
Scale=1:39.0
4.50 12 4x4 =
5 19
11
20
ADEQUATE 14
13
12
11
SUPPORT 3x5 11
4x5 =
6x8 =
3x5 11
REQUIRED.
-311-10 0-S
59-12
68-6
_ 11-2-0
131-6
13-&1514-6-3 i
371-10 -5-
5-4-4
0-11-72
4-4-6
1-11-6
0-7-60-11-4
Plate Offsets (X Y)-- f12:0-3-8 0-3-121 fl5:0-3-12 0-1-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.52
Vert(LL)
-0.09 12-13
>999
360
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.57
Vert(CT)
-0.17 12-13
>913
240
BCLL 0.0
Rep Stress Incr YES
WB 0.23
Horz(CT)
-0.06 9
n/a
n/a
BCDL 10.0
Code FBC2017/TPl2014
Matrix -MS
Wind(LL)
0.15 13
>999
240
Weight: 111 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x8 SP 240OF 2.0E *Except*
2-14: 2x4 SP No.3, 6-11: 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3 *Except*
2-16: 2x6 SP No.2
REACTIONS. All bearings 0-3-8 except Qt=length) 8; 1-2-12, 1=Mechanical.
(lb) - Max Harz 16=267(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) 8, 1 except 16=-433(LC 12), 9=-327(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 8, 1 except 16=726(LC 17), 9=623(LC 2)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-296/96, 3-5= 287/237, 5-6=-292/304
BOT CHORD 15-16= 459/400, 2-15= 488/319, 11-12=262/179
WEBS 13-15= 39/345, 3-13=-294/371, 10-12_ 480/670
Structural wood sheathing directly applied or 6-0-0 oc puffins,
except end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NbTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4 t; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 11-2-0, Exterior(2)
11-2-0 to 14-2-0 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Refer to girder(s) for truss to truss connections.
6) Bearing at joint(s) 16 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 1 except Qt=lb)
16=433, 9=327.
Waiter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/012015 BEFORE USE,
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiT e V
Is always required for stabllity and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUIPI i Qualify C1Seda, DS8.69 and SCSI Budding Component
Tampa, FL 33610
Safety /nfonnaMonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Job
Truss
Truss Type r ,
Qty
Ply
YANCY
T14482992
75240
P3
ROOF SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Jul 5 07.22:34 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-jY_nvGI 1yYngtmGUs?6c?BerZ08MQJL7HdR?_mz?BHp
4-0-0 Q-S-$ 5-0-11 9-7-15 11-2-011_�-10
4-0-0 5- 4-7-3 4-7-3 1-6-1 0- -10
v
n
0
0
K6 11 0
ADEQUATE 12 11 10
SUPPORT 5x6 = 3x6 II 5x6 =
REQUIRED.
Scale=1:32.9
3-11-10
5-0-11
9-7-15 10-31 11-2-10
3-11-10 5-
4-7-3
4-7-3 0 7 80 11 4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL) -0.00
11 >999 360
MT20
2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.26
Vert(CT) -0.01
11 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.18
Horz(CT) -0.00
1 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Wind(LL) 0.00
11 >999 240
Weight: 93 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 *Except*
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing,
Except:
10-12,7-9: 2x8 SP 2400F 2.0E
6-0-0 oc bracing: 2-13.
WEBS 2x4 SP No.3 *Except*
2-13: 2x6 SP No.2
REACTIONS. All bearings 0-3-8 except Qt=length) 7=1-2-12, 1=Mechanical.
(Ib) - Max Horz 13=341(LC 12)
Max Uplift All uplift 1001b or less atjoint(s) except 7= 253(LC 17), 1=-103(LC
12), 13=-267(LC 12), 8= 561(LC
12)
Max Grav All reactions 250 lb or less at joint(s) 7, 1 except 13=540(LC 1), 8=707(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BOT CHORD 2-13=-303/310, 11-12=-239/276, 10-11=-239/276, 5-9= 213/323
WEBS 4-10=-326/276, 4-12=-315/41
NOTES-
1j Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 11-0-14 zone;
porch left and right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Bearing at joint(s) 13 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 253 lb uplift at joint 7, 103 lb uplift at
joint 1, 267 Ito uplift at joint 13 and 561 lb uplift at joint 8.
Welter P. Finn PE No.22839
WTek USA, Inc. FL Cert 6634
69D4 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verlry design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03,2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an individual building component not
�•
a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Addllionai temporary and permanent bracing
�/� T
I V 1� e W
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUMII AaarByCiNelfa, OSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety lnronnationavailoble from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type r
Qty
Ply
YANCY
T14482993
75240
P4
MONOPITCH
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
-4-0-0
8.13o s Mar 11 2018 MI I eK maustrleS, Inc. I nu Jui b U/:L2:3b zu1 u i
1yJnkAMEaoizl kk3-BkYA7cJgrvXUwrhPierYOAOxQU89oXHWHBZWC.
i 1 7-9-1
5-8-13
Scale = 1:26.8
3x4 I I �
3
c 4.50 12 12
a
Y
• m
48
2 IF
11
0 O
0 0
�3 = 3x6 11
0
ADEQUATE 9 8
SUPPORT 3x6 II 5x6 =
REQUIRED.
-3-11-11 0-5-8, 6-2-5 6-9-13, 7-9-1 ,
3-11-11 0-5-8 5-8-13 0-7-8 0-11-4 '
Plate Offsets (X Y)-- (2.0-1-4 0-2-01
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Ildefl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.23
Vert(LL)
-0.00
8-9
>999
360
TCDL 10.0
Lumber DOL
1.25
BC 0.29
Vert(CT)
-0.01
8-9
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.06
Horz(CT)
-0.00
6
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Wind(LL)
0.00
7
>999
240
LUMBER -
TOP CHORD
2x4 SP M 30
BOT CHORD
2x4 SP No.3 *Except*
8-9,5-7: 2x8 SP 240OF 2.0E
WEBS
2x4 SP No.3 `Except'
2-10: 2x6 SP No.2
PLATES GRIP
MT20 244/190
Weight: 61 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
except end verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS. All bearings 0-3-8 except (jt=length) 1=Mechanical, 5=1-2-12.
(lb) - Max Harz 10=263(LC 12)
Max Uplift All uplift 100 lb or less at joint(s) except 1=-102(LC 12), 5=-167(LC 17), 10=-202(LC 12), 6=-418(LC
12)
Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 10=410(LC 1), 6=475(LC 1)
FORCES. (lb) - Max. Comp./Max Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 2-10= 356/305, 3-7= 271/404
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; 6=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2)-3-11-10 to-0-11-10, Interior(1)-0-11-10 to 7-7-5 zone; porch
left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Bearing at joint(s) 10 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 102 lb uplift at joint 1,167 lb uplift at
joint 5, 202 lb uplift at joint 10 and 418 lb uplift at joint 6.
Walter P. Finn PE No.22639
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE 1,111-7473 rev. 1010312015 BEFORE USE.
Design valid for use only wlih MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeAAk%WI1 Qualify Crifeda, DSS$9 and SCSI Building Component
6904 Parke East Blvd.
Safety /nformallonavoliable from Truss Plate Institute. 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type , r
Qty
Ply
YANCY
T14482994
75240
P5
MONOPITCH
1
1
Job Reference (optional)
Unambers I russ, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MI I eK Industries, Inc. I nu Jul 5 07:22:36 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoiztkk3-fw6YKyKHU91064QtzP945cj4AgpzuEcQkxw62ez?BHn
-2-5-0 0-5-8 2-8-12 4-3-8 ,
2-5-0 0-5-8 2-3-4 1-6-12
Scale = 1:17.6
0-5-3x6 II 2-8-12
0 2-3-4
5x6
--4
07 -8
4-3-8
0-5-8 -11-4
Plate Offsets (X,Y)--
f2:0-1-4,0-1-121
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC
0.65
Vert(LL)
0.00
9
>999
240
MT20
244/190
TCDL 10.0
Lumber DOL
1.25
BC
0.38
Vert(CT)
-0.00
9
>999
240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr
YES
WB
0.07
Horz(CT)
-0.00
6
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 34 lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP N0.3 *Except*
8-9,5-7: 2x8 SP 240OF 2.0E BOT CHORD
WEBS 2x4 SP No.3 *Except*
2-10: 2x6 SP No.2
REACTIONS. (lb/size) 5=38/1-2-12, 10=391/0-3-8, 6=36/0-3-8
Max Horz 10=313(LC 12)
Max Uplift 10= 436(LC 12), 6=-230(LC 9)
Max Grav 5=76(LC 17), 10=391(LC 1), 6=99(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BOT CHORD 2-10= 382/615
Structural wood sheathing directly applied or 4-3-8 oc puriins,
except end verticals.
Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B--45ft; L=24ft; eave=oft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -2-5-0 to 0-7-4, Interior(1) 0-7-4 to 4-1-12 zone; porch left and
right exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSUTPI 1.
3) All plates are MT20 plates unless otherwise indicated.
4) Gable studs spaced at 2-0-0 oc.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 10 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 436 lb uplift at joint 10 and 230 lb uplift
at joint 6.
Waller P. Finn PE No.22839
MiTek USA, Inc. FL Celt 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10A13/2015 BEFORE USE.
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an Individual building component not
a truss system. Before use, the building designer must venfy the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of masses and truss systems, weANSWI1 BualIfyCrBeda, DSB-89 and BCSI Bu9ding Component
6904 Parke East Blvd.
Safety Intonnaftonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type ,
Oty
Ply
YANCY
T14482995
75240
V5
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Jul 5 07:22:37 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-77gwYILvFTOFkE?3X7gJdpGNBEBpdivazbggb4z?BHm
2-6-3 5-0-5
2-6-3 2-6-3
Scale = 1:9.3
3x6 =
3.90 12
3X4
5-0-5
3X4
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
n/a
n/a
999
TCDL 10.0
Lumber DOL
1.25
BC 0.22
Vert(CT)
n/a
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00 3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 1=127/5-0-5, 3=127/5-0-5
Max Horz 1=13(LC11)
Max Uplift 1=-73(LC 12), 3=-73(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-16B/290, 2-3— 1681290
PLATES GRIP
MT20 244/190
Weight: 13 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-5 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE-7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
31 Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
Walter P. Finn PE No12839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity deslgn parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE M11-7473 rev. 10/012015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�'
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal injury and property damage. for general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAALURP/I Guafify ClBeda, DSB-89 and BCSf BuBdfng Component
6904 Parke East Blvd.
Safety intormallonavailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tama, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14482996
75240
V23
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2018 MiTek Industries, Inc. Thu Jul 5 07:22:37 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-77gwYlLvFTgFkE?3X7gJdpGFYEBzdh_azbggb4z?BHm
11-9-0 23-6-1
11-9-0 11.9-0
Scale = 1:37.1
4x4 =
3x4 % 9 87 6 3x4
2x3 II 3x6 = 2x3 I
2x3 11
23-6-1
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/dell
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.67
Vert(LL)
n/a
n/a
999
TCDL 10.0
Lumber DOL
1.25
BC 0.40
Vert(CT)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.12
Horz(CT)
0.00 5
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
PLATES GRIP
MT20 244/190
Weight: 78 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 23-6-1.
(lb) - Max Horz 1= 90(LC 10)
Max Uplift All uplift 100 lb or less atjoint(s) 1, 5 except 7=-155(LC 12), 6=-339(LC 12), 9=-339(LC 12)
Max Grav All reactions 250 Ib or less at joints) 1, 5 except 7=407(LC 1), 6=514(LC 22), 9=514(LC 21)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 3-7=-297/249, 4-6= 387/411, 2-9=-387/411
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=tft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-11-1 to 3-11-1, Interior(1) 3-11-1 to 11-9-0, Exterior(2)
11-9-0 to 14-9-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
b) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except Ot=lb)
7=155, 6=339, 9=339.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
WARNING. Verf/y design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI17473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Mi%k7
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUiNII QualBy CdIe11a, DSB-69 and SCSI Buffd/ng Component
6904 Parke East Blvd.
Safety InfonnatIonavailable from Truss Plate institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Oty
Ply
YANCY
T14482997
75240
VA
Valley
1
1
Job Reference (optional) I
Chambers Truss, Inc., Fort Pierce, FL
9-5-5
8.130 s Mar 112018 MiiTek Industries, Inc. Thu Jul 5 07:22:38 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizi kk3-bJDIleLYOmH6LNaF5gBYA1 oSydV3M8UjCEPD7Xz?BHI
4x4 =
Scale =1:29.8
3x4 9 8 7 6 3x4
2x3 11 3x6 = 2x3 11
2x3 11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.50
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.34
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.11
Horz(CT) 0.00 5 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 63 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. All bearings 18-10-10.
(lb) - Max Horz 1=-71(LC 10)
Max Uplift All uplift 100 lb or less at joints) 1, 5, 8 except 6=-286(LC 12), 9=-286(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 5, 8 except 6=435(LC 22), 9=435(LC 21)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
WEBS 4-6= 318/358, 2-9= 318/358
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-11-1 to 3-11-1, Interior(1) 3-11-1 to 9-5-5, Exterior(2) 9-5-5
to 12-5-5 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60
' plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
' will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 1, 5, 8 except
(t=lb) 6=286, 9=286.
Walter P. Finn PE No.22839
MIT& USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
e East Blvd.
6904 ParkeEast
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSV7P11 AualllyCdteda, DSB-89 and BCS1 SuUding Component
Tampa. 0
Safety lnfonnallotrovallabte from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Job
Truss
Truss Type
Qry
Ply
YANCY
Ti4482998
75240
VB
Valley
1
1
-Job
Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:39 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAM Eaoiz 1 kk3-4Vngy_MAn4PyzX9SeYiniELht1 vz5b4tQu9mfzz?BHk
14-3-3
Scale=1:22.5
4x4 =
8 7 6
3x4 % 2x3 11 2x3 II 2x3 II 3x4
14-3-3
14-3-3
Plate Offsets (X,Y)-- f2:0-0-0,0-0-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.23
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.04
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.08
Horz(CT) 0.00
5 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix-S
Weight: 45 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 14-3-3.
(lb) - Max Harz 1=-52(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 6= 195(LC 12), 8= 195(LC 12)
Max Grav All reactions 250 lb or less at joints) 1, 5, 7 except 6=296(LC
22), 8=296(LC 21)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
WEBS 4-6=-220/285, 2-8= 220/285
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave--tft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-11-1 to 4-0-0, Interior(1) 4-0-0 to 7-1-9, Exterior(2) 7-1-9 to
10-3-3 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except
Qt=lb) 6=195, 8=195.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
All, WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component not
Bet
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
{!!`SOW i
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSUMIT AualByCdfeda, DSB-69 and BCSI Bufld/ng Component
6904 Parke East Blvd.
Safety /nfolntaBanovailabie from Truss Plate Institute, 218 N. Lee Street Suite 312. Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type t
Qty
Ply
YANCY
T14482999
75240
VC
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MI IeK Industries, Inc. I nu Jul 5 01:22:41 2U1 B Page 1
ID:fc6ZRoaxnh?WJnkAMEaoizl kk3-OuvRNgOQJhfgCrlgmzkFofQ_trY9ZUK9uCetksz?BHi
4-9-14 9-7-12
4-9-14 4-9-14
Scale = 1:17.4
4x4 =
3.90 12
3x4
2x3 11
3x4
9-7-12
9-7-12
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.39
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.25
Vert(CT)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr YES
WB 0.10
Horz(CT)
0.00 3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-S
Weight: 28lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=133/9-7-12, 3=133/9-7-12, 4=359/9-7-12
Max Horz 1=-32(LC 10)
Max Uplift 1= 84(LC 12), 3=-84(LC 12), 4=-191(LC 12)
Max Grav 1=138(LC 21), 3=138(LC 22), 4=359(LC 1)
FORCES. (lb) - Max. Comp./Max Ten. - All forces 250 (Ib) or less except when shown.
WEBS 2-4=-245/336
Structural wood sheathing directly applied or 6-0-0 oc pudins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4fh Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-11-1 to 3-11-1, Interior(1) 3-11-1 to 4-9-14, Exterior(2)
4-9-14 to 7-9-14 zone; cantilever left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except Qt=lb)
4=191.
Wafter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MrTEK REFERANCE PAGE MIF7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors.lhis design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the Wilding designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addllional temporary and permanent bracing
nA T a'
IVI� e
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery. erection and bracing of trusses and Truss systems, seeANSYMIJ GualflyCrMeda, DS9.89 and BCSI Bumding Component
6904 Parke East Blvd.
Safety Infonnationavollabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandda, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14483000
75240
VE
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:41 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-OuvRNgOQJhfgCrlgmzkFofQ2grZjZVtouCetksz?BHi
2-3-4 4-6-9
2-3-4 2-3-4
3x6 =
Scale = 1:8.5
3.90 12
3x4
4-6-9
3x4
Plate Offsets (X Y)-- f2.0-3-0 Edgel
LOADING (pst)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.14
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.15
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 11 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 4-6-9 oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=108/4-6-9, 3=108/4-6-9
Max Harz 1= 11(LC 10)
Max Uplift 1=-62(LC 12), 3=-62(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=oft Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Extedor(2) zone; cantilever left and right exposed ;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
41 This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)1, 3.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MfrEK REFERAmcE PAGE MII-7473 rev. 10/012015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component not
�'
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
tlYlO 1P�
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANS//IPII QualityOffeda, DSB49 and SCSI Bufld/ng Component
6904 Parke East Blvd.
Safety Infonnallonavailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14483001
75240
VF
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:42 2018 Page 1
I D:fc6ZRoaxnh?vyJnkAMEaoizl kk3-U4Tpb?P24?nXq?tl KgGUKtzAFFuslxcJ7sNRGiz?BHh
4-7-0 9-2-0
4-7-0 4-7-0
4x4 =
3.90 12
Scale = 1:16.6
3x4 %
2x3 11
3x4
9-2-0
9-2-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
Well
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.35
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.22
Vert(CT)
n/a
n/a
999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.10
Horz(CT)
0.00 3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Mattix-S
Weight: 26 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=125/9-2-0, 3=125/9-2-0, 4=336/9-2-0
Max Horz 1— 30(LC 10)
Max Uplift 1=-79(LC 12), 3=-79(LC 12), 4— 179(LC 12)
Max Grav 1=129(LC 21), 3=129(LC 22), 4=336(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4=-230/327
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc putiins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL-4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft eave=4fh Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-11-1 to 3-11-1, Interior(1) 3-11-1 to 4-7-0, Exterior(2) 4-7-0
to 7-7-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
` plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except at=lb)
4=179.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
69U Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 114II-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MlTelc0 connectors. This design Is based only upon parameters shown, and Is for an individual building component not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
{SOW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSWI1 Qua/ByClBeda, DS8-89 and SCSI Bugdlgq Component
6904 Parke East Blvd.
Safety /nfounalfanovaliable from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type r
Oty
Ply
YANCY
T14483002
75240
VG
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:43 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-yG 1 BoLPgrJvOSOSDtNnjt4WMZeEH 1 OmSLW7_okz?BHg
6-10-11 IV
6-10-11 1-4-8
3.90 F,2
2x3 11
3x6 =
3x4 11
Scale: 3/4'=1'
T
m
3x4 5;
2x3 II
3x4 II
8-3-3
B-3-3
Plate Offsets (X Y)--
(3:0-3-0 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.32
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 10.0
Lumber DOL ' 1.25
BC 0.21
Vert(CT)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr YES
WB 0.10
Horz(CT)
-0.00 5
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix-S
Weight: 27 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=109/8-3-3, 5=143/8-3-3, 6=324/8-3-3
Max Horz 1=93(LC 12)
Max Uplift 1=-44(LC 12), 5= 85(LC 12), 6= 203(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-6=-247/348
Structural wood sheathing directly applied or 6-0-0 oc pudins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL--4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft eave=4fh Cat.
III; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) 0-11-1 to 4-1-9, Interior(1) 4-1-9 to 6-10-11, Exterior(2)
6-10-11 to 8-1-7 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Gable requires continuous bottom chord bearing.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
e) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except at=lb)
6=203.
Welter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE 11111-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�
a miss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
{1AiTeW
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANS&VI1 CualffyCriteria, DSO-69 and SCSI BuIld/ng Component
6904 Parke East Blvd.
Safety /n►oaaaf ianovailable from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314,
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
YANCY
T14483003
75240
VH
Valley
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07.,22:44 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizi kk3-QTbZOhQfccl F311 PR51yP12Uf2TpmsdcaAsXt4Az?BHf
667
6-6-7
Scale = 1:14.4
3x5 11
2
1
4x5 %
3x5 II
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.49
Vert(LL)
n/a
n/a
999
MT20 244/190
TCDL 10.0
Lumber DOL
1.25
BC 0.64
Vert(CT)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 21 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 31 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 1=219/6-6-7, 3=219/6-6-7
Max Harz 1=108(LC12)
Max Uplift 1=-109(LC 12), 3= 144(LC 12)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-180/429
Structural wood sheathing directly applied or 6-0-0 oc puffins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDLf1.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) 0-11-1 to 5-1-15, Exterior(2) 5-1-15 to 6-4-11 zone; cantilever
left and right exposed ;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
31 This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=109, 3=144.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cott 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/0 MIS BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify The applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is To prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
n� !
MiTeW
Is always required for stability and to prevent collapse wlth possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and tracing of trusses and truss systems, seeANSUIPll QualifyCaeda, DSB.89 and BCSIBuilding Component
6904 Parke East Blvd.
Safety /nformallonavatlable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type . •
Qty
Ply
YANCY
T14483004
75240
VK
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:45 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-uf9yD 1 RxMw96hScc?opl3yVbc8Sw?VJtlpgc5tdz?BHe
4-2-12
Scale = 1:9.6
3x4 ; 3x4 II
I
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.69
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 10.0
Lumber DOL 1.25
BC 0.20
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00 n/a n/a
BCDL 10.0
Code FBC2017lTP12014
Matrix-P
Weight: 13lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 1=126/4-2-12, 3=126/4-2-12
Max Horz 1=62(LC 12)
Max Uplift 1=-63(LC 12), 3=-83(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3= 108/298
Structural wood sheathing directly applied or 4-2-12 oc purlins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4; 2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone; cantilever left and right exposed ;C-C for members and
forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
31 This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
Waller P. Finn PE No22839
MTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
® WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�'
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indlcated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANWWII Quality CiCeda, DSO-89 and 8CSI Building Component
6904 Parke East Blvd.
Safety InfomlaHonovailable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Oty
Ply
YANCY
T14483005
75240
VL
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 112018 MiTek Industries, Inc. Thu Jul 5 07:22:45 2018 Page 1
ID:fc6ZRoaxnh?vyJnkAMEaoizl kk3-ufgyD 1 RxMwg6hScc?opByVbm3SzoVJtfpgc5tdz?BHe
1-11-1
1-11-1
3x4
3.90 12
Scale =1:5.8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.06
Vert(LL) n/a
n/a 999
MT20 2441190
TCDL 10.0
Lumber DOL 1.25
BC 0.02
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
Weight: 4lb FT=20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-11-1 oc puffins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 1=40/1-11-1, 2=30/1-11-1, 3=10/1-11-1
Max Harz 1=20(LC 12)
Max Uplift 1=-20(LC 12), 2=-29(LC 12)
Max Grav 1=40(LC 1), 2=30(LC 1), 3=20(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less
except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone; cantilever left and right exposed ;C-C for members and
forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires continuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2.
Walter P. Finn PE No.22839
IATek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
July 5,2018
A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M114473 rev, 10/03MIS BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, sooANSWI1 Quality CrBelb DS8.69 and SCSI SuIldlgg Component
6904 Parke East Blvd.
Safety ONormoffe favallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Symbols
PLATE LOCATION AND ORIENTATION
31 Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ff-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
-
-I-
For 4 x 2 orientation, locate
plates 0-110 from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
'Plate location details available in M►Tek20120
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
IndustryStandards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses,
Numbering System
6-4-8 dimensions shown In ff-in-sixteenths
(Drawings not to scale)
2
TOP CHORDS
0
C1-2 C2-3
c,� 4
WEBS
C
c
U
a
O
~
c7-8 c6a c5-6
BOTTOM CHORDS
0
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTMED BY END JOINT
NUMBERSAETTERS
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 s
A General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, Individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and i� the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
Indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
In all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18, Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
Is not sufficient.
20. Design assumes manufacture in accordance with