Design Certification for Wind Load Compliance
This.Certification is to be completed by the project design architect or engineer. This Certification musfbe submitted.with all . .
applications for building permits involving the construction of new residence(single or multi-family),residential addition,any' ,
accessory structure requiring a building permit,and any nonresidential structure.'This Certification shall not apply_to interior. `
renovations(provided that no structural walls,columns or other similar component is being effected)and certain other minor building
permits. For further assistance,please contact the'Building Inspection Office at 462-1553 or 462-2172:,.
Pro•ectName ► ?,U5r, K1±51DWC . Office Use_ Only
Street Address Permit Number
FT FL Occupancy Type S H ;
Construction Type
Certification Statement:
I certify that,to the best of my knowledge and belief, these plans and specifications have been designed to
comply with the applicable structural portion of-the Building Codes currently adopted,and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind.
loads and forces specified-by current code provisions.
`Design Parameters and Assumutions Used: (Please check or complete the appropriate box:)
%t Florida Building Code 2004 Edition ,/ ASCE 7-98
'2' Building Design is (check one) Enclosed ✓ Partially Enclosed Open Building
i
3.Building Height: 45"I(o 4,Wind Speed Used in Building Design: 1 40 3 second gust
5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line#1):
6. Average Wind Velocity Pressure on Exterior Faces of Structure �J3 .3 PSF
1 Peak Wind Velocity Pressure on Exterior Faces of Structure 43.2- PSF
8.Imp6rtance/Use Factor(obtain from Building Code): :.
9. Loads:. Floor t o0 PSF Roof/dead a7 PSF Roof/live JO PSF
10.Were Shear Walls Considered for Structure(check one): Yes ✓ No (if No,attach explanation)
11. Is a Continuous Load Path Provided(check one): Yes /_No (if No,attach explanation)
-12,Are Component and Cladding Detail Provided (check one): Yes_Y[-No (if No,attach explanation)
13. Minimum Soil Bearing'Pressure: PSF
As witnessed by my seal,I hereby certify that the information included with this certification is true and
correct, to the best of my knowledge and belief. ;
Name: Certification#: �.03« S ere]
Design Firm: JtOW E b 6USHQU St, PE Date: '2/,z6 f 0 7
SLCCDV Form#020-00 rev. 10/5105 ding