HomeMy WebLinkAboutDouglas - Underlayment Approval.pdf11/18121, 10:15 AM
Florida Building Code Online
Professional1
rA Gym . - ��.�]
SOS ]come Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us SOS Site Map Emirs Search
dopr
(L l��ProducbAppraval
cruel USER: Public User
PrOdGCt Approval Menu > PrOduQ Or Appli[dGon Search > Apphra[ion uss > Application Detail
FL # FL2569-R23
• Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
(819) 478-2400
memathieu@ soprema. ca
Authorized Signature Marc -Etienne Mathieu
memathieu @soprema.ca
Technical Representative Marc -Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext 3327
memathieu@soprema.ca
Quality Assurance Representative
lean -Francois Cote, Ph.D.
Address/Phone/Email
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category
Roofing
Subcategory
Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert 1. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated 6y John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R23 C01 2021 01 CO NIEMI EN.pdF
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D4601 2012
ASTM D4798 2011
FM 4474 2011
FRSA/TRI Sixth Edition 2018
TAS 103 2020
UL1897 2015
https:ttflorida bu ilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 9 08Erxl Ud3xYldTUyLi2pFprvGZEoRjE%2fHg%3d%3d 1 /2
11/18/21, 10:15 AM
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Valldated
Date Pending FBC Approval
Date Approved
Method 1 Option D
07/29/2021
08/03/2021
08/09/2021
10/12/2021
auprimary m vrwum
FL •
Model, Number or Name
Description
2569.1 Sophisms Roof Underlayments for Self adhering roof underlayments
use In FBC HVHZ jurisdictions
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL2569 R23 II 2021 07 29 FINAL ER SOPREMA HVHZ FL2569-
Approved for use outside HVHZ: No 82LP&
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: N/A Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports
FL2569 R 3 AF 2021 07 29 FINAL R SOPR MA HVHZ F 2 6-
923aI7df
I Created by Independent Third Party: Yes
4569.2
Soprema RooF Undenayments for
Self adhering roof underayments
use In FBC non-HVHZ jurisdictions
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL2569 R23 It 2021 07 22 FINAL ER SOPREMA NOW
HVHZ FL2569-R23 Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen, P.E. PE-59166
Oesign Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.)
Evaluation Reports
The design pressure noted herein pertains to
FL2569 R23 AE 2021 07 29 FINAL ER SOPREMAN
HVHZ FL2569-R23.12df
underlayment systems used beneath the roof systems.
Refer to ER Section 5.8.3 for details.
Created by Independent Third Party: Yes
Contact Us :: 26D1 Blair Some Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AAILEO employe, Copyright 2007-2013 State of Ronal :: Pnvag Statement :: Accessibility Statemen
Under nonce law, email addresses are public records. If you do not want your e-mail address released In response M a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall, If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide Me Department with an email address If they have one. the *malls
provided may be used for official communication with Me licensee. However email addresses are public record. If you do not wish m supply a perspnal address, please
provide Me Department win an email address which can be made available to Me public. To determine If you are a licensee under Chapter 455, FS., please dick bs¢.
rVeduct Approval Accepts:
®®®
Credit Card
Safe
https:l/Boridabuilding.org/pdpr_app_d0.aspx?pamm=wGEVXOwtDgsKOFEnckB108Eni1Ud3xYldTUyLi2pFpwGZEoRjE%2fHg%3d%3d 212
0
NEMO l etc.
Certificate of Authorization 832455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
'1N RFPC
Soprema, Inc. Evaluation Report S18010.06.09-RZ1
1640 rue Haggerty FL2569-R23 (NON-HVHZ)
Drummondville, Qu6bec 12C SP8 Canada Date of Issuance: 06/15/2009
(819) 478-2400 Revision 21: 07/29/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7"' Edition (2020) Florida Building Code sections noted herein.
DEscnivnow Soprema Roof Underlayments for use In F8C non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO) etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8
Prepared by:
,,,,.,..q,,,M -
Robert J.M. Nieminen P.E.
SST. eeT3 CT, �,y
so - �''< The Facsimile seal appearing was authorized by Robert
'k,�,zI;,*;
Florida Registration No. 59166, Florida DCA ANE1983
9
•*gip,, „' Nieminen, P.E. on o7/29/2021. This does not serve as
/g:":•�m,"'
an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
ONEMO etc.
ROOFING COMPONENT EVALUATION:
Product Category:
Roofing
Sub -Category.
Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance
with the following sections of the 71° Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
STANDARDS:2.
Section
Property
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1, 1507.2.4, 1507.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
1507.3.3 / R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Endtr
Examination
Reference
Date
ERD (TST6049)
Wind Resistance
2779.07.05
07/15/2005
ERD (TST6049)
FRSA/TRI 04-12 (MS)
S43530.02.14-1-R1
02/21/2014
ERD(TST6049)
ASTM D1970 (QC)
S44870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
S44870.04.14-4
04/10/2014
ERD (TST6049)
ASTM D1970(OH)
S40540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.04.14
04/27/2015
ERD(TST6049)
Wind Resistance
SOPC-SC3404S.05.17-RS
06/07/2017
NEMO (TST6049)
ASTM D1970 / TAS 110 (QC)
SOPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.08.18
08/27/2018
NEMO (TST6049)
Tile Slippage
4S-SOPC-18-002.09.18
09/21/2018
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SOPC-18-002.05.19.A
05/31/2019
NEMO (TST6049)
Tensile Adhesion/Long Term Aging
4p-DOW-I9-SSLAP-01.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-20-SSUDL-01.A
01/07/2021
NEMO (TST6049)
ASTM D1970 (MS)
41-SOPC-2I-SSUDL-01.A
04/19/2021
PRI (TSTS878)
ASTM D19701MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
NEMO
Traceability
FBC Cross -Listing
07/28/2021
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC (QUA9625)
Quality Control
Florida BCIS
Current
NEMO ETC, LLC Evaluation Report 518010.06.09-R21
Certifrote ofAWh.n,.tlon N32455 7'- EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R23(NON-HVHZ)
Soprema Roof Underlayments Revision 21: 07/29/2021
Page 2 of 8
M
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
fONEMOjetc.
PRODUCTDESCRIPTION:
Product
Material
Plant(s)
Description
Standard
LASTOBOND TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyesterfabric
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
SRS TopShield DEFENDER
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
TU
FRSA/TR109-18
surfaced, SBS modified bitumen roof
underlayment
Tri-Built S/A HT TU
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
Underlayment
FRSA/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
LASTOBOND Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
40
modified bitumen roof underlayment
LASTOBOND Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
LASTOBOND Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
LASTOBOND Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Enviro5hield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
LASTOBOND Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
LASTOBOND Smooth
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
Tri-Built Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film-
Underlayment
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
RESISTO L81236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
TRI-BUILT Sand-R SA
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Shingle Underlayment
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
NEMO ETC, LLC Evaluation Report S18010.06.09-R21
Certificate o)Auffionzotion a32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FLZ569-R23 (NON-HVHZ)
Soprema Roof Underlayments Revision 21t 07/29/2021
Page 3 of 8
4.17
4.18
ONEIVIOletc.
Product
Material
Standard
plants)
Description
SRS TopShield ICE &
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, 58S modified bitumen roof
Wadsworth, OH
I underlayment
5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
fKJedkn.
1507J
1507.3
1507.4 A 1507.5
1507.7
150J111507.9
Gay and Concrete Tile
Metal
Slate or
Underlaymant
Slate -Type
Shalm or
W Shi
Mechanical
Adhesive-
Shiingleslt
Attach
Set
Panels
Shingles
Shingles
ngles
LASTOBOND TU HT, SRS TopShield
Yes
Yes
DEFENDER TU, Tri-Built S/A HT TU
Yes
Yes
Yes
Yes
Yes
ONMs ,,ss .LL3/
Underlayment
See 5.6.1
MS.LL3)
LASTOBOND Shield, Pro HT-N, RESISTO
Yes
SA SMOOTH PLY 40
yes
No
No
Yes
Yes
Yes
pdM SMas. tsm.t.l3/
R905.1.13)
Yes
LASTOBOND Shield HT, Pro HT-S
Yes
No
No
Yes
Yes
Yes
0o1ntnapyt5U.LL3/
0.905.LL3)
Yes
EnviroShield
Yes
No
No
Yes
Yes
Yes
poiMmlw,tw7.t.t.3/
R905.LL3)
LASTOBOND ECO, RESISTO L31236, TRI-
BUILT Sand-R SA Shingle Underlayment,
Yes
Grip -Rite Eave& Valley Protector,
Yes
No
No
No
No
Yes
point strips, LWl.1.1.3/
TopShield ICE & WATER DEFENDER,
asos.l.L3)
RESISTO LB1244
LASTOBOND Smooth Seal HT, Tri-Built
Yes
Smooth Hr S/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
(MM Adps. LW1.1.33/
Smooth Seal HT
I
I
I
M.1.1.3)
NEMO ETC, LLC Evaluation Report s18010.06.09-R21
Cer f icate ofAuthori:ation a32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.2569-1173 (NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021
Page 4 of 8
ONEMOletc.
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment/ tile -adhesive combinations.
TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERULYMENr COMBINATIONs1
Underlayment
Adhesive
Florida Product Approval
LASTOBOND TU HT, SRS
TopShleld DEFENDER TU, Tri-
Built S/A HT TU Underlayment
Dupont "Tile Bond- Roof Tile Adhesive"
FL22525
ICP Adhesives and Sealants "Polysete AH-160"
FL6332
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment
Application
Type Primer Material(s)
LASTOBOND Shield, LASTOBOND Pro HT-
(Optional) ASTM
Plywood, OSB or Southern Yellow
N, RESISTO SA SMOOTH PLY 40,
Deck /
D41, Elastocol Stick,
Pine (SYP)
LASTOBOND Shield HT, LASTOBOND Pro
sheathing
Elastocol Stick Zero
ASTM D41
structural concrete
HT-S, Enviro5hield, LASTOBOND TU HT,
SRS TopShield DEFENDER TU, Tri-Built
(Optional) Elastocol
Dens Deck Prime or SECUROCK
S/A HTTU Underlayment, LASTOBOND
*>teg _
Insulation
Stick Zero
Gypsum -Fiber Roof Board
ECO, RESISTO LB1236, TRI-BUILT Sand-R
adhering
SA Shingle Underlayment, Grip -Rite Eave
& Valley Protector, TopShield ICE &
WATER DEFENDER, RESISTO L11244,
Base Sheet
(Optional) Elastocol
ASTM D226, Type II felt or
LASTOBOND Smooth Seal HT, Tri-Built
Stick Zero
Modified Sopra-G
Smooth HT S/A Underlayment or Grip -
Rite Smooth Seal HT
LASTOBOND TU HT, SRS TopShield
DEFENDER TU, Tri-Built S/A HT TU
Existing sand -surfaced, glass -fiber
Underlayment, RESISTO LB1236, TRI-
self-
Existing
RESISTO EXTERIOR
surfaced, mineral -surfaced or film -
BUILT Sand -RSA Shingle Underlayment,
adhering
substrate
PRIMER
surfaced roofunderlayment•
Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER
Final acceptance of any existing substrate In a reroof (tearoff) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive LASTOBOND TU HT, SRS TopShield
DEFENDER TU, Tri-Buih S/A HT TU Underlayment RESISTO LB1136, TRI-BUILT Sand-R SA Shingle Underlayment Grip -Rite Eave & Valley
Protector or TopShield ICE & WATER DEFENDER self -adhering underloyments, Contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.8 Attachment Umitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturers installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturers installation
instructions, but —for mechanically attached base sheets - not less than Section 5.8.3 herein.
Refer to Tile Manufacturers or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report 538010.06.09-RZ1
Certificate ofAuthonrotion k32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-R23 (NON-HVHZ)
Soprema Roof Underlaymems Revision 21:07/29/2021
Page 5 of 8
ONEMOletc.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Table 1A or the critical (highest)
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, self -adhered and
back -nailed within the selvedge -edge side laps using 12 ga. x W ring shank nails through 32 ga., 1-5/8"
diameter tin caps spaced 12-Inch o.c..
#2 Maximum Design Pressure =-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built 5/A HT TU Underlayment, self -adhered and
back -nailed within the selvedge -edge side laps using 12 ga. x W ring shank nails through 32 ga., 1-5/8"
diameter tin raps spaced 12-inch o.c..
#3 Maximum Design Pressure = -120.0 psf
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Bulk S/A HT TU Underlayment, self -adhered and
back -nailed within the selvedge -edge side laps using 12 ga. x IY." ring shank nails through 32 ga., 1-5/8"
diameter tin caps spaced 12-inch o.c..
#4 Maximum Design Pressure=-150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, self -adhered and
back -nailed within the selvedge -edge side laps using 12 ga. It W ring shank nails through 32 ga.,1-5/8"
diameter tin caps spaced 12-Inch o.c..
#5 All other direct -deck, adhered underiayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Table SA orthe critical (highest)
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
PRIME design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated
pressure zones shall employ an attachment density by a qualified design professional to resist the elevated
pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing
Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk'
carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
NEMO ETC, LLC Evaluation Report 518010.06.09-R21
Certijirote of Authorization#32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL2569-RZ3 (NON-HVHZ)
Soprema Roof Underlayments Revision 21:07/29/2021
Page 6 of 8
ONEMOletc.
#6 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Buik S/A HTTU Underlayment, self -adhered and
back -nailed within the selvedge -edge side laps using 12 ga. x 19" ring shank nails through 32 ga., 1-5/8"
diameter tin raps spaced 12-inch o.c.
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EVOSURE LLMRATHM
Prepared Roof Cover
Maximum
Underlayment
Installatlon Type
Exposure (days)
LASTOBOND Eco, RESISTO L81236, TRI-BUILT Sand-R SA Shingle Underlayment,
Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO
Mechanically attached
30
LB1244
LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40,
LASTOBOND Shield HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth
Mechanically attached
90
Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT
LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU
Mechanically attached or
adhesive -set tile roof
180
Underlayment
system
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT4)Ec3 TILE IN6TALIATLOf[S
Underlayment
Tile Profile
Staging Method
Maximum Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Double -tile stacking method, as shown below
6:12
LASTOBOND TU HT,
SRS TopShield
DEFENDER TU, Tri-Built
S/A HT TU
Lugged
Underlayment
r
i
NEMO ETC, LLC Evaluation Report 518010.06.09-R21
Certificate afAuthudwtlon#32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION F1.2569-1123 (NON-HVHZ)
Soprema Roof Underlaymems Revision 21: 07/29/2021
Page 7 of 8
NNEMO I etc.
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO L81236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3 LASTOBOND TU HT, SRS TopShield DEFENDER TU, Tri-Built S/A HT TU Underlayment, LASTOBOND Shield,
LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT, LASTOBOND Pro HT-S,
EnviroShield, LASTOBOND Eco, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite
Smooth Seal HT, RESISTO L81236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D3970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When Installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.3.2 Tile Applications:
Limited to LASTOBOND TU HT, SRS TopShield DEFENDER TU or Tri-Built S/A HT TU Underlayment.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NE.fN�pIO ETC, LLC Evaluation Report 518010.06.W-R21
Ceroffwm oJAumoNzoNan a32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F12569-R23 (NON-HVH2)
Soprema Roof Underlayments Revision 21: 07/29/2021
Page 9 of 8