Loading...
HomeMy WebLinkAboutROOFING INFO SHEET 2110-0450LL! L.IL � 31 ST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6,7 Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE VV KS Section A (General Information) Master Permit No. �i� L� cj Process No. Contractors Name: SEAN CARTER License # CCC1329896 Job Address 7506 SAN CARLOS AVE FT. PIERCE, FL 34951-2168 ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles M Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance M Reroofing ❑ Recovering r .ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 2� (O Steep Sloped Roof Area (SF) Z C Total (SF) 1 �_7 z Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. l ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: C�AF Product Approval No.: FU Wj .4" Raq Design Wind Pressures, From RAS 128 Or Calculations: Zone 1'% Zone 1: Zone 2: __Zone 3: Max. Design Pressure, from the specific product approval system: 17.5 Deck: Type:_ PI Uwu t� Gauge Thickness: 3/t/ Slope: I , ( , Anchor/Base Sheet & No. df Ply(s): _ 3 Anchor/Base Sheet Fastener/Bonding Material: P-P,LI 4 34,c.k Insulation Base Layer: r't /A Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): .3 Base Sheet Fastener/Bonding Material: Pf f 1 + S4111ic Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: C.c, P _sAee7�- Top Ply Fastener/Bonding Material: 12c9/1+ 54'(< Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_.._." oc @ Lap, # Rows_ @ "oc Zone 1:_" oc @ Lap, # Rows ® "oc Zone 2:—" oc @ Lap, # Rows ® "oc Zone 3:—" oc @ Lap, # Rows_ @ "oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE��� z Section D (Steep Slope Roof System) Roof System Manufacturer: (S Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): .Zone 1: f `'�L Zone 2e: 1� Zone 2n: Zone 2r:Zone 3e:—_Zone 3r: Deck Type: \Typenderent Roof lope: �'� S -� � c-l� ' 2 N rrier:Rid�e Ventilatiopstener Type &Spacing: Udl r Adhesive Type: [ l Si c"c— CIL Type Cap Sheet: S l %� „ Mean Roof Height: ° i L5 2!mI Roof Covering: Type & Size Drip Edge: