HomeMy WebLinkAboutSHINGLES PRODUCT APPROVAL CROSSFlorida Building Code Online
Page 1 of 2
BCIS Home Log In User Registration Hot Topic. Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
dU Product Approval
4USER: Public User
Product Approval Menu > Produc[ or Applcaton Search > Application List > Application Detail
FL # FL10124-R29
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800)766-3411
mstieh@gaf.com
Authorized Signature Robert Nieminen
Ireith@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
TechnicalQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nieminen
the Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
12/16/2022
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL10124 R29 COI 2020 01 COI NIEMINEN odf
Standard
ASTM D1970
ASTM D3161
ASTM D3462
ASTM D7158
TAS 107
Year
2015
2016
2010
2019
2020
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquracBe VCbdM... 2/10/2021
Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
12/21/2020
12/21/2020
12/26/2020
02/09/2021
FL #
Model, Number or Name
Description
10124.1
GAF Asphalt Roof Shingles
Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge
asphalt shingles
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Installation Instructions
FL10124 R29 II 2020 12 21 FINAL ER GAF ASPHALT
SHINGLES F 101 4-Rg Ddf
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section 5.
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL10124 R29 AE 2020 12 21 FINAL ER GAF ASPHALT
SHINGLES FL101 4-Rg Ddf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone• 850-48T+824
The State of Florida Is an WEED employer. Coovriaht 2007-2013 State of Florida :: privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a pubiic•recards request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The
emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click baL.
Product Approval Accepts:
,S wnur.
Credit Card
Safe
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquracBe VCbdM... 2/ 10/2021
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
GAF Evaluation Report 01506.01.08-1132
1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
FL10124-R30
Date of Issuance: 01/03/2008
Revision 32: 05/19/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7eh Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be clone in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
1;,.., �1`. Ci ,motto-S?':^.'!� '••:y
Robert J.M. Nieminen P.E. c" The facsimile seal appearing was authorized by Robert
z `'rrcS= �^ 4 ' Nieminen, P.E. on 05/19/2021. This does not serve as an
Florida Registration No, 59166, Florida DCA ANE1983 !, Pt� :� a...s'electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
9)2018 NEMO ETC, LLC
ONEMOJetc.
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category:
Roofing
Sub -Category:
Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as
produced by GAF, have demonstrated compliance with the
following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following
Standards. Compliance is
subject to the Installation Requirements
and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, R905.2.3
Material standard
ASTM D1970
2015
1507.2.5, R905.2.4
Material standard
ASTM D3462
2010
1S07.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2019
1507.2.7.1, R905.2.6.1
Wind Resistance
TAS 107
2020
3. REFERENCES:
Entity
Examination
Reference
Date
PRI (TST 5878)
Physical Properties
GAF-025-02-01
03/27/2002
PRI (TST 5878)
ASTM D3462
GAF-059-02-01
09/02/2004
PRI (TST 5878)
ASTM D3462
GAF-080-02-01
05/25/2005
PRI (TST 5878)
Physical Properties
GAF-324-02-01
12/01/2011
PRI (TST 5878)
ASTM D1970 (QuickStart)
GAF-340-02-01
03/13/2012
PRI (TST 5878)
Wind Driven Rain
GAF-407-02-01
01/21/2013
PRI (TST 5878)
Wind Driven Rain
GAF-895-02-01
11/20/2018
PRI (TST 5878)
Wind Driven Rain
GAF-896-02-01
11/20/2018
PRI (TST 5878)
ASTM D3462
GAF-897-02-01
11/08/2018
PRI (TST 5878)
ASTM D3462
GAF-898-02-01
11/08/2018
PRI (TST 5878)
ASTM D3462
GAF-899-02-01
11/15/2018
PRI (TST 5878)
ASTM D3462 (IN-MV)
376TO133
02/05/2021
PRI (TST 5878)
ASTM D3462 (CA-S)
376TO135
02/05/2021
PRI (TST 5878)
ASTM D3462(IN-MV)
376TO163
04/20/2021
UL (TST 1740)
ASTM D3462
93NK6295
11/29/1993
UL (TST 1740)
ASTM D3462
99NK43835
01/12/2000
UL (TST 1740)
TAS 107
94NK9632
03/29/2000
UL(TST 1740)
ASTM D3462
01NK06632
02/02/2001
UL (TST 1740)
ASTM D3161, TAS 107
01NK9226
05/21/2001
UL (TST 1740)
ASTM D3161
01NK37122
12/18/2001
UL (TST 1740)
ASTM D3462
01NK37122
12/19/2001
UL (TST 1740)
ASTM D3161, TAS 107
02NK12980
04/10/2002
UL (TST 1740)
ASTM D3161, TAS 107
02NK30871
09/09/2002
UL (TST 1740)
ASTM D3161
03CA5367
03/11/2003
UL (TST 1740)
ASTM D3462
03NK26444
10/17/2003
UL (TST 1740)
ASTM D3462
04NK13850
06/07/2004
UL (TST 1740)
ASTM D3161
04NK13850
06/23/2004
UL (TST 1740)
ASTM D3161
04NK30546
03/10/2005
UL (TST 1740)
ASTM D3462
04NK22009
05/06/2005
UL(TST 1740)
ASTM D3161
04NK22009
05/09/2005
UL (TST 1740)
ASTM D3462
05NK27924
02/10/2006
UL (TST 1740)
ASTM D3161
05NK27924
02/11/2006
UL (TST 1740)
ASTM D3161,D3462
06CA18077
06/05/2006
UL (TST 1740)
ASTM D3161,D3462
06CA18074
06/16/2006
UL (TST 1740)
ASTM D3161,D3462
06CA35251
10/18/2006
NEMO ETC, LLC Evaluation Report 01506.01.08-1132
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30
GAF Asphalt Roof Shingles Revision 32: 05/19/2021
Page 2 of 8
ONEMOjetc.
gflim
Examination
Reference
Date
UL (TST 1740)
ASTM D3462
06CA31603
12/01/2006
UL (TST 1740)
ASTM D3161,D3462
06CA41095
12/27/2006
UL (TST 1740)
ASTM D3161
07NK05228
03/13/2007
UL (TST 1740)
ASTM D3161
06CA31611
04/04/2007
UL (TST 1740)
ASTM D3161
06CA61148
04/09/2007
UL (TST 1740)
ASTM D3161,D3462
07CA31742
11/08/2007
UL (TST 1740)
ASTM D3161,D7158,D3462
08CA06100
03/13/2008
UL (TST 1740)
ASTM D3161,D3462
07CA55908
04/01/2008
UL (TST 1740)
ASTM D3161,D3462
09CA10592
03/26/2009
UL (TST 1740)
ASTM D3161,D3462
09CA068S6
05/15/2009
UL (TST 1740)
ASTM D3161,D7158,D3462
09NK06647
08/01/2009
UL (TST 1740)
ASTM D3161,D7158,D3462
09CA27281
08/27/2009
UL (TST 1740)
ASTM D3161,D7158,D3462
10CA35554
03/05/2010
UL (TST 1740)
ASTM D3161,D7158,D3462
10CA13686
05/15/2010
UL (TST 1740)
ASTM D3462
10CA07264
05/27/2010
UL (TST 1740)
ASTM D3462
10CA11953
10/29/2010
UL (TST 1740)
ASTM D3161,D7158,D3462
1ONK11951
10/30/2010
UL (TST 1740)
ASTM D3161,D7158,D3462
10NK12070
11/04/2010
UL (TST 1740)
ASTM D3161,D7158,D3462
08CA06100
01/30/2010
UL (TST 1740)
ASTM D3161,D7158,D3462
10CA53934
03/31/2011
UL (TST 1740)
ASTM D3161,D7158,D3462
11CA48924
10/22/2011
UL (TST 1740)
ASTM D3161,D7158,D3462
11CA47919
12/03/2011
UL (TST 1740)
ASTM D3161,D7158,D3462
11CA48408
12/08/2011
UL (TST 1740)
ASTM D3161,D7158,D3462
11CA48725
12/09/2011
UL, LLC. (TST 9628)
ASTM D3462
12CA34891
10/12/2012
UL, LLC. (TST 9628)
ASTM D3161,D7158,D3462
12CA58151
02/15/2013
UL, LLC. (TST 9628)
ASTM D3161
12CA38083
02/26/2013
UL, LLC. (TST 9628)
ASTM D3161
13CA32332
06/18/2013
UL, LLC. (TST 9628)
ASTM D3161
13CA37934
08/02/2013
UL, LLC. (TST 9628)
ASTM D3161,D7158,D3462
4786875675
07/17/2015
UL, LLC. (TST 9628)
ASTM D3161,D7158,D3462
4787434542
05/17/2016
UL, LLC. (TST 9628)
ASTM D3161,D7158,D3462
4788717529
09/09/2016
UL, LLC. (TST 9628)
ASTM D3161
4788698165
11/09/2018
UL, LLC. (TST 9628)
ASTM D3161
4788669132
12/13/2018
UL, LLC, (TST 9628)
ASTM D3161
4788891098
02/14/2019
UL, I.I.C. (TST 9628)
ASTM D3161,D7158,D3462
4788932264
08/16/2019
UL, LLC. (TST 9628)
ASTM D3161,D7158,D3462
4789115488
08/16/2019
UL, LLC. (TST 9628)
ASTM D3161
4788959558
10/17/2019
UL, I.I.C. (TST 9628)
ASTM D3161,D7158,D3462
4786508528
11/01/2019
UL, LLC. (TST 9628)
ASTM D3161
4789132672
10/27/2020
UL, LLC. (QUA 9625)
Quality Control
Service Confirmation
10/18/2018
UL, LLC. (QUA 9625)
Quality Control
Florida BCIS
Current
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type
Product
Description
material
Plant(s)
Standard
Pro -Start® Starter Strip Shingles
(fka, Pro -Start® Eave/Rake Starter
starter strips for asphalt roof shingles
ASTM D3462
CA-S, IN-MV, TX-D
Accessory
Strip Shingles)
Starter
mineral -surfaced, fiberglass -reinforced, self -
Strips
p
®
QuickStart Peel &Stick Starter
adhering SBS modified bitumen starter strip,
Roll
nominal 9-inch x 33 ft roll, for use with
ASTM D1970
CA-S, IN•MV
asphalt shingles with exposure of 6-inch or
less
NEMO ETC, LLC Evaluation Report 01506.01.08-1132
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30
GAF Asphalt Roof Shingles Revision 32: 05/29/2021
Page 3 of 8
ONFMniPtr
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type
Product
Description
Material
Standard
Plant(s)
color -coordinated starter strips for use with
Accessory
StarterMatch" Starter Strip
Shingles
Grand Canyon® and Grand Sequoia® series
asphalt shingles. StarterMatch® are installed
as the second starter for Grand Canyon® and
ASTM D3462
CA-F
Starter
Grand Sequoia® series installations
Strips
WeatherBlockerT" Premium
Starter Strip Shingles (fka,
WeatherBlockerTI Premium
starter strips for asphalt roof shingles
ASTM D3462
IN-MV
Eave/Rake Starter Strip Shingles)
Marquis WeatherMaxs
IN-MV
Royal Soverei ns
g
AL, CA-F, FL, GA, IN -
MV, PA, 'TX-D
fiberglass reinforced 3-tab asphalt roof
shin les
shingles
g
ASTM D3462
Sentinel®
GA, IN-MV, TX-D
Camelot" II
IN-MV
Fortitude®
PA
Glenwood®
IN-MV
Grand Canyon"
CA-F, IN•MV
Grand Sequoia"
CA-F, IN-MV
Grand Sequoia" IR
CA-F, IN-MV
Grand Sequoia® ArmorShield®
CA-F
Grand Sequoia" AS
CA-F
Tirnberline® American Harvest®
AL, CA-F, IN••MC, PA
Timberline® AH
AL, CA-F, IN -MC, PA
Timberline® ArmorShield® it
TX-E
Timberlines AS II
TX-E
Timberlines Cool Series
CA-F
Asphalt
Shingles
fiberglass reinforced, laminated asphalt
roof shingles
ASTM D3462
Timberlines CS
CA-F
Timberline HDs
AL, CA-S, CA-F, FL, IN -
MC, MD, MN, PA, TX-
D, TX-E
AL, CA-F, CA-S, FL, IN -
Timberline" HDZT"
MC, MD, MN, PA, TX-
D, TX-E
Timberline" Natural Shadows
AL, CA-S, IN -MC, MD,
MN, PA, TX•.D, ME
AL, CA-S, FL, IN -MC,
Timberlines NS
MD, MN, PA, TX-D, TX-
E
Timberline Ultra HDs
AL, CA-S, IN -MC, PA,
ME
Timberline" UHD
AL, CA-S, IN -MC, PA,
ME
Woodland"
IN-MV
SlatelineTM
fiberglass reinforced 5-tab asphalt roof
shingle
ASTM D3462
IN-MV
Seal -A -Ridge® ArmorShield"
GA
Seal -A -Ridge AS
GA
Hip &
Ridge
Shingles
fiberglass reinforced, hip and ridge
asphalt roof shingles
ASTM D3462
S al-A-RidgeO Ridge Cap Shingles
GA, IN-MV
Timbertex" Premium Ridge Cap
Shingles
IN-MV
NEMO ETC, LLC
Certificate of Authorization #31455
7- EDITION (2020) FBC NON-HVHZ EVALUATION
GAF Asphalt Roof Shingles
Evaluation Report 01506.01.08-1132
FL10124-R30
Revision 32: 05/19/2022
Page 4 of 8
ONEMOletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i,e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction,
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications
TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES
Product
FBC Table 1507.2.7.1 or R905.2.6.1
Marquis WeatherMax®
ASTM D3161(F) & ASTM D7158(H)
Royal Sovereigns
ASTM D3161(F) & ASTM D7158(H)
Sentinel®
ASTM D3161(F) & ASTM D7158(H)
Camelot® II
ASTM D3161(F) & ASTM D7158(H)
Fortitude®
ASTM D3161(F) & ASTM D7158(H)
Glenwood®
ASTM D3161(F) & ASTM D7158(H)
Grand Canyon®
ASTM D3161(F) & ASTM D7158(H)
Grand Sequoia®
ASTM D3161(F) & ASTM D7158(H)
Grand Sequoia® IR
ASTM D3161(F) & ASTM D7158(H)
Grand Sequoia® ArmorShield®
ASTM D3161(F) & ASTM D7158(H)
Grand Sequoia® AS
ASTM D3161(F) & ASTM D7158(H)
Timberline® American Harvest®
ASTM D3161(F) & ASTM D7158(H)
Timberline® AH
ASTM D3161(F) & ASTM D7158(H)
Timberline® ArmorShield® II
ASTM D3161(F) & ASTM D7158(H)
Timberline® AS 11
ASTM D3161(F) & ASTM D71S8(H)
Timberline® Cool Series
ASTM D3161(F) & ASTM D7158(H)
Timberline® CS
ASTM D3161(F) & ASTM D7158(H)
Timberline HD®
ASTM D3161(F) & ASTM D7158(H)
Timberline® HDZT1
ASTM D3161(F) & ASTM D7158(H)
Timberline® Natural Shadow®
ASTM D3161(F) & ASTM D7158(H)
Timberline® NS
ASTM D3161(F) & ASTM D7158(H)
Timberline Ultra HD®
ASTM D3161(F) & ASTM D7158(H)
Timberline® UHD
ASTM D3161(F) & ASTM D7158(H)
Woodland®
ASTM D3161(F) & ASTM D7158(H)
SlatelineTM
ASTM D3161(F) & ASTM D7158(H)
5.5.1 Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
NEMO ETC, LLC Evaluation Report 01506.01.08-1132
Certificate of Authorization #31455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30
GAF Asphalt Roof Shingles Revision 32: 05/19/2021
Page 5 of 8
ONEMOJetc.
TABLE 28: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE
Type
Product
FBC Table 1507.2.7.1 or R905.2.6.1
Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake
ASTM D3161, Class F
Starter Strip Shingles)
Starter Strips
WeatherBlockerTM Premium Starter Strip Shingles (fka,
ASTM D3161, Class F
WeatherBlocker Premium Eave/Rake Starter Strip Shingles)
Seal -A -Ridge® ArmorShield®
ASTM D3161, Class F
Seal -A -Ridge® AS
ASTM D3161, Class F
Hip &Ridge
Shingles
Seal -A -Ridge® Ridge Cap Shingles
ASTM D3161, Class F
Timbertex® Premium Ridge Cap Shingles
ASTM D3161, Class F (sealant
required, See Section 6)
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 610320-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally
Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.1.4 GAF asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations
set forth in FBC Section 1511 or R908 and GAF published installation instructions.
6.2 STARTER SHINGLES OR STARTER STRIP:
6.2.1 Installation of Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake Starter Strip Shingles), WeatherBlocker TM
Premium Starter Strip Shingles (fka, WeatherBlocker'"' Premium Eave/Rake Starter Strip Shingles) and QuickStarte
Peel & Stick Starter Roll shall comply with the GAF current published instructions.
6.3 ASPHALT SHINGLES:
—6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4)
nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Camelot® 11, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield®, and
Woodland® require minimum five (5) nails per shingle.
➢ Slateline'"" requires minimum six (6) nails per shingle.
NEMO ETC, LLC Evaluation Report 01506.01.08-1132
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30
GAF Asphalt Roof Shingles Revision 32: 05/19/2021
Page 6 of 8
ONEMOjetc.
6.3.2 Fastening for Fortitude®, Timberline® AH, Timberline® CS and Timberline® HDZ'"; slopes 2:12 up to 21:12
39-3/8" (1 m)
11-5/8' - 14-5i8' (295mm - 372mm) 11-5/8' - 14-5/8- (295mm - 372mm)
W2-- 2-12' (13mm - 64mm) 12' - 2-1/2' (13mm - 64mm)
131/4" r
1/
r
6 7I/8"
TARGET NAIL ZONE
^ ZONA OBJETIVO DE CLAVADO
5-13/16' - 1-5/8' (148mm - 194mm)
F F F ri
1174 -1
1 f
STANDARD NAILING PATTERN:
Nail shingles approximately 6 7/8" (174 mm) from bottom of shingle, in nailing area, as shown. Nails must not be exposed. Not for use on
Mansard roofs (21:12 slope and above).
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required.
Contact the GAF for details.
Fastening for Fortitude®, Timberline® AH, Timberline® CS and Timberline® HDZ'"; slopes greater than 21:12
6.4 HIP & RIDGE SHINGLES:
6.4.1 Installation of Seal -A -Ridge® Ridge Cap Shingles
shall comply with the GAF current published "
instructions with a minimum two (2) nails,
minimum 3/8-inch head diameter located 6-7/8-
inch back from the exposed end and 0.5-inch 6y°�"�`\ / -. Nail
from the edge. \� Clavo
NEMO ETC, LLC Evaluation Report 01506.01.08-1132
Certificate of Authorization #31455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30
GAF Asphalt Roof Shingles Revision 32: 05/19/2021
Page 7 of 8
6.4.2 Installation of Seal -A -Ridge® ArmorShield® and
Seal -A -Ridge® AS shall comply with the GAF
current published instructions with a minimum
two (2) nails, minimum 3/8-inch head diameter,
per shingle located 5.25-inch back from the
exposed end and 1-inch from the edge.
6.4.3 Installation of Timbertex® Premium Ridge Cap
Shingles shall comply with GAF current
published instructions with a minimum two (2)
nails, minimum 3/8-inch head diameter, per
shingle and beads of Sonneborn "NP1 Gun Grade
Polyurethane Sealant" or Henkel "PL Roofing
and Flashing Sealant".
ONEMOjetc.
1 ^
11.5°
(292 mm)
Sealant
1'
(25 rnm)
Sellante
(25 mm1 Enduit d'6lanch(WO
I
Nail
Clavo
12"
(305 mm)
Clouer
91'
(229 mm)
12"
(305 mm)
REQUIREMENTS:7. BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
UL LLC—QUA9625; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 01506.01.08-R32
Certificate of Authorization #31455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30
GAF Asphalt Roof Shingles Revision 32: 05/19/2021
Page 8 of 8