Loading...
HomeMy WebLinkAboutSHINGLES PRODUCT APPROVAL CROSSFlorida Building Code Online Page 1 of 2 BCIS Home Log In User Registration Hot Topic. Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search dU Product Approval 4USER: Public User Product Approval Menu > Produc[ or Applcaton Search > Application List > Application Detail FL # FL10124-R29 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen Ireith@nemoetc.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 TechnicalQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/16/2022 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL10124 R29 COI 2020 01 COI NIEMINEN odf Standard ASTM D1970 ASTM D3161 ASTM D3462 ASTM D7158 TAS 107 Year 2015 2016 2010 2019 2020 http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquracBe VCbdM... 2/10/2021 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 12/21/2020 12/21/2020 12/26/2020 02/09/2021 FL # Model, Number or Name Description 10124.1 GAF Asphalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FL10124 R29 II 2020 12 21 FINAL ER GAF ASPHALT SHINGLES F 101 4-Rg Ddf Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5. Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL10124 R29 AE 2020 12 21 FINAL ER GAF ASPHALT SHINGLES FL101 4-Rg Ddf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone• 850-48T+824 The State of Florida Is an WEED employer. Coovriaht 2007-2013 State of Florida :: privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a pubiic•recards request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click baL. Product Approval Accepts: ,S wnur. Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDquracBe VCbdM... 2/ 10/2021 NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT REPORTEVALUATION GAF Evaluation Report 01506.01.08-1132 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 FL10124-R30 Date of Issuance: 01/03/2008 Revision 32: 05/19/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7eh Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be clone in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: 1;,.., �1`. Ci ,motto-S?':^.'!� '••:y Robert J.M. Nieminen P.E. c" The facsimile seal appearing was authorized by Robert z `'rrcS= �^ 4 ' Nieminen, P.E. on 05/19/2021. This does not serve as an Florida Registration No, 59166, Florida DCA ANE1983 !, Pt� :� a...s'electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 9)2018 NEMO ETC, LLC ONEMOJetc. ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, R905.2.3 Material standard ASTM D1970 2015 1507.2.5, R905.2.4 Material standard ASTM D3462 2010 1S07.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 2020 3. REFERENCES: Entity Examination Reference Date PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) ASTM D1970 (QuickStart) GAF-340-02-01 03/13/2012 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 PRI (TST 5878) Wind Driven Rain GAF-895-02-01 11/20/2018 PRI (TST 5878) Wind Driven Rain GAF-896-02-01 11/20/2018 PRI (TST 5878) ASTM D3462 GAF-897-02-01 11/08/2018 PRI (TST 5878) ASTM D3462 GAF-898-02-01 11/08/2018 PRI (TST 5878) ASTM D3462 GAF-899-02-01 11/15/2018 PRI (TST 5878) ASTM D3462 (IN-MV) 376TO133 02/05/2021 PRI (TST 5878) ASTM D3462 (CA-S) 376TO135 02/05/2021 PRI (TST 5878) ASTM D3462(IN-MV) 376TO163 04/20/2021 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 01NK06632 02/02/2001 UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001 UL (TST 1740) ASTM D3161 01NK37122 12/18/2001 UL (TST 1740) ASTM D3462 01NK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CA5367 03/11/2003 UL (TST 1740) ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL (TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL (TST 1740) ASTM D3462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL (TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL (TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 NEMO ETC, LLC Evaluation Report 01506.01.08-1132 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30 GAF Asphalt Roof Shingles Revision 32: 05/19/2021 Page 2 of 8 ONEMOjetc. gflim Examination Reference Date UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL (TST 1740) ASTM D3161 07NK05228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL (TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 UL (TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL (TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161,D3462 09CA068S6 05/15/2009 UL (TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010 UL (TST 1740) ASTM D3161,D7158,D3462 10CA13686 05/15/2010 UL (TST 1740) ASTM D3462 10CA07264 05/27/2010 UL (TST 1740) ASTM D3462 10CA11953 10/29/2010 UL (TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL (TST 1740) ASTM D3161,D7158,D3462 10NK12070 11/04/2010 UL (TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL, LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012 UL, LLC. (TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL, LLC. (TST 9628) ASTM D3161 13CA37934 08/02/2013 UL, LLC. (TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL, LLC. (TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL, LLC. (TST 9628) ASTM D3161,D7158,D3462 4788717529 09/09/2016 UL, LLC. (TST 9628) ASTM D3161 4788698165 11/09/2018 UL, LLC. (TST 9628) ASTM D3161 4788669132 12/13/2018 UL, LLC, (TST 9628) ASTM D3161 4788891098 02/14/2019 UL, I.I.C. (TST 9628) ASTM D3161,D7158,D3462 4788932264 08/16/2019 UL, LLC. (TST 9628) ASTM D3161,D7158,D3462 4789115488 08/16/2019 UL, LLC. (TST 9628) ASTM D3161 4788959558 10/17/2019 UL, I.I.C. (TST 9628) ASTM D3161,D7158,D3462 4786508528 11/01/2019 UL, LLC. (TST 9628) ASTM D3161 4789132672 10/27/2020 UL, LLC. (QUA 9625) Quality Control Service Confirmation 10/18/2018 UL, LLC. (QUA 9625) Quality Control Florida BCIS Current TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Description material Plant(s) Standard Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake Starter starter strips for asphalt roof shingles ASTM D3462 CA-S, IN-MV, TX-D Accessory Strip Shingles) Starter mineral -surfaced, fiberglass -reinforced, self - Strips p ® QuickStart Peel &Stick Starter adhering SBS modified bitumen starter strip, Roll nominal 9-inch x 33 ft roll, for use with ASTM D1970 CA-S, IN•MV asphalt shingles with exposure of 6-inch or less NEMO ETC, LLC Evaluation Report 01506.01.08-1132 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30 GAF Asphalt Roof Shingles Revision 32: 05/29/2021 Page 3 of 8 ONFMniPtr TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Description Material Standard Plant(s) color -coordinated starter strips for use with Accessory StarterMatch" Starter Strip Shingles Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch® are installed as the second starter for Grand Canyon® and ASTM D3462 CA-F Starter Grand Sequoia® series installations Strips WeatherBlockerT" Premium Starter Strip Shingles (fka, WeatherBlockerTI Premium starter strips for asphalt roof shingles ASTM D3462 IN-MV Eave/Rake Starter Strip Shingles) Marquis WeatherMaxs IN-MV Royal Soverei ns g AL, CA-F, FL, GA, IN - MV, PA, 'TX-D fiberglass reinforced 3-tab asphalt roof shin les shingles g ASTM D3462 Sentinel® GA, IN-MV, TX-D Camelot" II IN-MV Fortitude® PA Glenwood® IN-MV Grand Canyon" CA-F, IN•MV Grand Sequoia" CA-F, IN-MV Grand Sequoia" IR CA-F, IN-MV Grand Sequoia® ArmorShield® CA-F Grand Sequoia" AS CA-F Tirnberline® American Harvest® AL, CA-F, IN••MC, PA Timberline® AH AL, CA-F, IN -MC, PA Timberline® ArmorShield® it TX-E Timberlines AS II TX-E Timberlines Cool Series CA-F Asphalt Shingles fiberglass reinforced, laminated asphalt roof shingles ASTM D3462 Timberlines CS CA-F Timberline HDs AL, CA-S, CA-F, FL, IN - MC, MD, MN, PA, TX- D, TX-E AL, CA-F, CA-S, FL, IN - Timberline" HDZT" MC, MD, MN, PA, TX- D, TX-E Timberline" Natural Shadows AL, CA-S, IN -MC, MD, MN, PA, TX•.D, ME AL, CA-S, FL, IN -MC, Timberlines NS MD, MN, PA, TX-D, TX- E Timberline Ultra HDs AL, CA-S, IN -MC, PA, ME Timberline" UHD AL, CA-S, IN -MC, PA, ME Woodland" IN-MV SlatelineTM fiberglass reinforced 5-tab asphalt roof shingle ASTM D3462 IN-MV Seal -A -Ridge® ArmorShield" GA Seal -A -Ridge AS GA Hip & Ridge Shingles fiberglass reinforced, hip and ridge asphalt roof shingles ASTM D3462 S al-A-RidgeO Ridge Cap Shingles GA, IN-MV Timbertex" Premium Ridge Cap Shingles IN-MV NEMO ETC, LLC Certificate of Authorization #31455 7- EDITION (2020) FBC NON-HVHZ EVALUATION GAF Asphalt Roof Shingles Evaluation Report 01506.01.08-1132 FL10124-R30 Revision 32: 05/19/2022 Page 4 of 8 ONEMOletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i,e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction, 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Marquis WeatherMax® ASTM D3161(F) & ASTM D7158(H) Royal Sovereigns ASTM D3161(F) & ASTM D7158(H) Sentinel® ASTM D3161(F) & ASTM D7158(H) Camelot® II ASTM D3161(F) & ASTM D7158(H) Fortitude® ASTM D3161(F) & ASTM D7158(H) Glenwood® ASTM D3161(F) & ASTM D7158(H) Grand Canyon® ASTM D3161(F) & ASTM D7158(H) Grand Sequoia® ASTM D3161(F) & ASTM D7158(H) Grand Sequoia® IR ASTM D3161(F) & ASTM D7158(H) Grand Sequoia® ArmorShield® ASTM D3161(F) & ASTM D7158(H) Grand Sequoia® AS ASTM D3161(F) & ASTM D7158(H) Timberline® American Harvest® ASTM D3161(F) & ASTM D7158(H) Timberline® AH ASTM D3161(F) & ASTM D7158(H) Timberline® ArmorShield® II ASTM D3161(F) & ASTM D7158(H) Timberline® AS 11 ASTM D3161(F) & ASTM D71S8(H) Timberline® Cool Series ASTM D3161(F) & ASTM D7158(H) Timberline® CS ASTM D3161(F) & ASTM D7158(H) Timberline HD® ASTM D3161(F) & ASTM D7158(H) Timberline® HDZT1 ASTM D3161(F) & ASTM D7158(H) Timberline® Natural Shadow® ASTM D3161(F) & ASTM D7158(H) Timberline® NS ASTM D3161(F) & ASTM D7158(H) Timberline Ultra HD® ASTM D3161(F) & ASTM D7158(H) Timberline® UHD ASTM D3161(F) & ASTM D7158(H) Woodland® ASTM D3161(F) & ASTM D7158(H) SlatelineTM ASTM D3161(F) & ASTM D7158(H) 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC, LLC Evaluation Report 01506.01.08-1132 Certificate of Authorization #31455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30 GAF Asphalt Roof Shingles Revision 32: 05/19/2021 Page 5 of 8 ONEMOJetc. TABLE 28: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE Type Product FBC Table 1507.2.7.1 or R905.2.6.1 Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake ASTM D3161, Class F Starter Strip Shingles) Starter Strips WeatherBlockerTM Premium Starter Strip Shingles (fka, ASTM D3161, Class F WeatherBlocker Premium Eave/Rake Starter Strip Shingles) Seal -A -Ridge® ArmorShield® ASTM D3161, Class F Seal -A -Ridge® AS ASTM D3161, Class F Hip &Ridge Shingles Seal -A -Ridge® Ridge Cap Shingles ASTM D3161, Class F Timbertex® Premium Ridge Cap Shingles ASTM D3161, Class F (sealant required, See Section 6) 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 610320-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 GAF asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and GAF published installation instructions. 6.2 STARTER SHINGLES OR STARTER STRIP: 6.2.1 Installation of Pro -Start® Starter Strip Shingles (fka, Pro -Start® Eave/Rake Starter Strip Shingles), WeatherBlocker TM Premium Starter Strip Shingles (fka, WeatherBlocker'"' Premium Eave/Rake Starter Strip Shingles) and QuickStarte Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 ASPHALT SHINGLES: —6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Camelot® 11, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield®, and Woodland® require minimum five (5) nails per shingle. ➢ Slateline'"" requires minimum six (6) nails per shingle. NEMO ETC, LLC Evaluation Report 01506.01.08-1132 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30 GAF Asphalt Roof Shingles Revision 32: 05/19/2021 Page 6 of 8 ONEMOjetc. 6.3.2 Fastening for Fortitude®, Timberline® AH, Timberline® CS and Timberline® HDZ'"; slopes 2:12 up to 21:12 39-3/8" (1 m) 11-5/8' - 14-5i8' (295mm - 372mm) 11-5/8' - 14-5/8- (295mm - 372mm) W2-- 2-12' (13mm - 64mm) 12' - 2-1/2' (13mm - 64mm) 131/4" r 1/ r 6 7I/8" TARGET NAIL ZONE ^ ZONA OBJETIVO DE CLAVADO 5-13/16' - 1-5/8' (148mm - 194mm) F F F ri 1174 -1 1 f STANDARD NAILING PATTERN: Nail shingles approximately 6 7/8" (174 mm) from bottom of shingle, in nailing area, as shown. Nails must not be exposed. Not for use on Mansard roofs (21:12 slope and above). 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Fastening for Fortitude®, Timberline® AH, Timberline® CS and Timberline® HDZ'"; slopes greater than 21:12 6.4 HIP & RIDGE SHINGLES: 6.4.1 Installation of Seal -A -Ridge® Ridge Cap Shingles shall comply with the GAF current published " instructions with a minimum two (2) nails, minimum 3/8-inch head diameter located 6-7/8- inch back from the exposed end and 0.5-inch 6y°�"�`\ / -. Nail from the edge. \� Clavo NEMO ETC, LLC Evaluation Report 01506.01.08-1132 Certificate of Authorization #31455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30 GAF Asphalt Roof Shingles Revision 32: 05/19/2021 Page 7 of 8 6.4.2 Installation of Seal -A -Ridge® ArmorShield® and Seal -A -Ridge® AS shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle located 5.25-inch back from the exposed end and 1-inch from the edge. 6.4.3 Installation of Timbertex® Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn "NP1 Gun Grade Polyurethane Sealant" or Henkel "PL Roofing and Flashing Sealant". ONEMOjetc. 1 ^ 11.5° (292 mm) Sealant 1' (25 rnm) Sellante (25 mm1 Enduit d'6lanch(WO I Nail Clavo 12" (305 mm) Clouer 91' (229 mm) 12" (305 mm) REQUIREMENTS:7. BUILDING PERMIT As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. UL LLC—QUA9625; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 01506.01.08-R32 Certificate of Authorization #31455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10124-R30 GAF Asphalt Roof Shingles Revision 32: 05/19/2021 Page 8 of 8