Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2020 PolyGlass ModiBit PRODUCT APP
NNEMO I etc. APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE DESCRIPTIONTABLE DECK APPLICATION TYPE 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-12 1C Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 12-14 1D Wood New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14-15 1E Wood New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 15-19 1F Wood New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 19-23 1G Wood New or Reroof (Tear -Off) E-2 Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 23-29 1H Wood New, Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 29-36 11 Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 37 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 38-43 213 Steel or Structural concrete New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 44-50 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51-53 2D Steel or Structural concrete New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Velociflex, Bonded Roof Cover 53-55 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 56-68 3B Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 68 4A Lightweight concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 69-73 4B Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 73-47 4C Lightweight concrete New or Reroof (Tear -Off) E-2 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 74-78 5A Cementitious wood fiber Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 79-80 5B Cementitious wood fiber Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 80-82 5C Cementitious wood fiber Reroof (Tear -Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 82 5D Cementitious wood fiber Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 83 5E Cementitious wood fiber Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 83 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 84-88 6B Existing gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 88 6C Existing gypsum Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 88 6D Existing gypsum Reroof (Tear -Off) or Recover E-2 Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 88 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 89-94 7B Various Recover F Non -Insulated, Bonded Roof Cover 94 NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for FL1654-R27 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 94 NNEMO I etc. The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: Minimum 1-inch plywood penetration or wood plank embedment. ➢ Steel Deck: Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: Minimum 1-inch embedment into pilot hole in accordance with published installation instructions. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non -wind -uplift -related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ Hot asphalt (HA): Full coverage at 25-30 Ibs/square. ➢ DuPont INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ H.B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ H.B. Fuller Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table. ➢ H.B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): MDP = -157.5 psf (Min. 0.5-inch thick) ➢ H.B. Fuller Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP = -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP = -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (OB500): MDP = -187.5 psf (Min. 0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP = -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ ICP Adhesives & Sealants Polyset CR-20: MDP = -117.5 psf (Min. 1.0-inch thick) 8 For adhered roof insulation and board -size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for F1.1654-1127 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 94 NNEMO I etc. ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO (FBC CER1592). Use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, unless otherwise noted, refer to the following. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION BP -AA Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II (Base and Ply sheets, Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Hot Asphalt at 20-40 Asphalt -Applied) Note: Asphalt -applied sheets or insulation shall not be applied to poly film surfaced membranes. Ibs/square Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT SBS-CA1 Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex PG350 at 1.5-2.0 gal/square S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP Polyplus 35 at 1.5-2.0 SBS-CA2 Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex gal/square S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex 56 HP, Elastoshield HT SBS-AA Hot Asphalt at 20 40 (SBS, Asphalt -Applied) Cap Ply Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Ibs/square Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Note: Asphalt -applied sheets or insulation shall not be applied to poly film surfaced membranes. Base Ply or Ply One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT SBS-TA Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 Torch -Applied (SBS, Torch -Applied) Cap Ply G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed) NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 3 of 94 NNEMO I etc. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-SA-H Base Ply Elastobase SA Self -adhering (followed (SBS, Self -Adhering, Hybrid Systems) by torch -applied sheet) Base Ply One or more plies Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR, Elastoflex SA Base HD SBS-SA Cap Ply Elastoflex SA P, Elastoflex SA P FR, Polyreflect (SBS, Self -Adhering) Note: Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein, Self -Adhering Elastobase (poly/sand) or Elastobase (poly/poly). APP-CA1 Cap Ply Polyflex G FR PG350 at 1.5-2.0 gal/square APP-TA Base Ply or Ply One or more plies Polyglass Base, Polyflex, Polybond (APP, Torch -Applied) Cap Ply Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR Torch -Applied APP-SA-H Base Ply Polyflex SA Base Self -adhering (followed (APP, Self -Adhering, Hybrid Systems) by torch -applied sheet) Cap Ply Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polyfresko G SA FR, Polykool APP-SA (APP, Self -Adhering) Note: Unless otherwise noted, permissible membrane substrates for APP-SA are limited to the SBS-SA Base Ply options herein, Self -Adhering Elastobase (poly/sand) or Elastobase (poly/poly). 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies. VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE -APPLIED INSULATION PER TABLE 3A: OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE (NOTE 15) APPLICATION C-VB-1. PG100 Elastoflex SA V Plus Self -Adhering D-IS or CR-20, 12-inch D.C. -60.0 C-VB-2. PG100 Polyglass Base Torch -applied D-IS or CR-20, 12-inch D.C. -75.0 C-VB-3. PG100 Elastoflex SA P Self -Adhering D-IS, 12-inch D.C. -75.0 C-VB-4. PG100 Elastoflex SA P Self -Adhering M-OSFA, 12-inch D.C. -157.5 C-VB-5. I PG100 Elastoflex SA P Self -Adhering I CR-20, 12-inch o.c. -270.0 C-VB-6. PG100 Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR Self -Adhering M-OSFA, M-PG-1, OB500 or CR-20, 12-inch o.c. -290.0 C-VB-7. PG100 SBS-TA (with sanded -top -surface) Torch -applied M-OSFA, M-PG-1, OB500 or CR-20, 12-inch D.C. -290.0 17 The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings for application limitations and a Roofing Materials Directory for fire ratings associated with coating usage. SURFACING OPTIONS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS OPTION # SURFACING FLORIDA PRODUCT APPROVAL SURF-1. PG 300 FL10291 SURF-2. PG 600 FL10291 SURF-3. PG 650 FL10291 SURF-4. PG 700 FL10291 SURF-5. PG 700 CIS FL10291 SURF-6. PG 800 FL10291 SURF-7. Polyplus 60 FL10291 NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for FL1654-R27 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 94 NNEMO I etc. SURFACING OPTIONS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS OPTION # SURFACING FLORIDA PRODUCT APPROVAL SURF-8. Polyplus 65 FL10291 SURF-9. PolyBrite 60-FC NOA 20-0611.01 SURF-10. PolyBrite 70 FL10291 SURF-11. PolyBrite 70 QS FL10291 SURF-12. PolyBrite 75 FL10291 SURF-13. PolyBrite 71 HS FL10291 SURF-14. PolyBrite 90 FL10291 SURF-15. PolyBrite 90.1 NOA 19-0610.02 SURF-16. PolyBrite 95 FL10291 SURF-17. PolyBrite 95.1 NOA 19-0610.02 SURF-18. KM Acryl 15 FL27409 SURF-19. KM Acryl 15 QS FL27409 SURF-20. KM Acryl 25 FL27409 SURF-21. KM Acryl 25 QS FL27409 SURF-22. KM Acryl 40 HS FL27409 SURF-23. KM Acryl 85 FL27409 SURF-24. KM PS#250 FL27409 SURF-25. KM PS#220 FL27409 SURF-26. Turbo -Set FL10291 18 "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads ABLE IA: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) BONDED INSULATION,BONDED ROOFCOVER Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) Deck System No. (Note 1) Type Attach Type Attach Base Ply Ply MDP Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) SELF -ADHERING BASE PLY: Min. 15/32- Min. 1.5-inch Polytherm, ACFoam II, Polytherm D-IS, M-OSFA, (Optional) additional D-IS, M-OSFA, (Optional) SBS-SA, SBS- SBS-SA, APP-SA, W-1 inch G, ACFoam III, ENRGY-3, Polytherm H, H-Shield, layers(s) of base SBS-SA -52.5 plywood H-Shield CG, Multi -Max FA3 OB500 or CR-20 insulation OB500 or CR-20 TA, APP-TA SBS-TA, APP-TA HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 15/32- Min. 1.5-inch Polytherm, ACFoam II, Polytherm (Optional) additional W-2 inch G, ACFoam III, ENRGY-3, Polytherm H, H-Shield, D-IS, M-OSFA, layers(s) of base D-IS, M-OSFA, APP-SA-H (Optional) APP-TA APP-TA -52.5 plywood H-Shield CG, Multi -Max FA3 OB500 or CR-20 insulation OB500 or CR-20 HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 15/32- Min. 1.5-inch Polytherm, ACFoam II, Polytherm (Optional) additional W-3 inch G, ACFoam III, ENRGY-3, Polytherm H, H-Shield, layers(s) of base SBS-SA-H (Optional) SBS-TA SBS-TA -52.5 plywood H-Shield CG, Multi -Max FA3 0 or CR-, OB500 or CR-20 OB500 insulation 0 or CR-, OB500 OB500 or CR-20 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-1127 Revision 25: 09/30/2020 Appendix 1, Page 5 of 94 NNEMO I etc. TABLE 1B: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) Deck System No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap Ply MDP (psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Ply ASPHALT -APPLIED OR TORCH -APPLIED BASE PLY: 9-inch o.c. at min. (Optional) Min. 1.5- Min. 0.75-inch Fesco Min. 2-inch lap and 18- inch Polytherm, Board 15/32- Elastobase, Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, (homogeneous) or BP -AA (Optional) SBS-AA, W-4 inch Elastobase P Cap equally spaced, Polytherm H, H-Shield, Hot asphalt min. 0.5-inch Hot asphalt or SBS- BP -AA or SBS-TA, -45.0* (sanded -top) Structodek High AA SBS-AA APP-TA plywood staggered center H-Shield CG, Multi- Density Fiberboard rows Max FA3 Roof Insulation 9-inch o.c. at min. (Optional) Min. 1.5- Min. 0.25-inch BP -AA, Min. 2-inch lap and 18- inch Polytherm, (Optional) 15/32- Elastobase, Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, DensDeck, DensDeck SBS- BP -AA, SBS SBS-AA, W-5 inch Elastobase P Cap equally spaced, Polytherm H, H-Shield, Hot asphalt Prime, SECUROCK Hot asphalt AA, AA, SBS-TA, SBS-TA, -45.0* (sanded -top) Gypsum -Fiber Roof SBS-TA, APP-TA plywood staggered center H-Shield CG, Multi- Board APP-TA APP-TA rows Max FA3 9-inch o.c. at min. (Optional) Min. 1.5- Min. 0.75-inch Fesco Board Min. Elastobase, 2-inch lap and 12- inch Polytherm, (homogeneous) or BP -AA (Optional) SBS-AA, W-6 15/32- Elastobase P Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, Hot asphalt min. 0.5-inch Hot asphalt or SBS- BP -AA or SBS-TA, -52.5 inch (sanded -top) Cap equally spaced, Polytherm H, H-Shield, Structodek High AA SBS-AA APP-TA plywood staggered center H-Shield CG, Multi - Density Fiberboard rows Max FA3 Roof Insulation 9-inch o.c. at min. (Optional) Min. 1.5- Min. 2-inch lap and 12- inch Polytherm, Min. 0.25-inch BP -AA, (Optional) 15/32- Elastobase, Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, DensDeck, DensDeck SBS- BP -AA, SBS SBS-AA, W-7 inch Elastobase P Cap equally spaced, Polytherm H, H-Shield, Hot asphalt Prime, SECUROCK Hot asphalt AA, AA, SBS-TA, SBS-TA, -52.5 (sanded -top) Gypsum -Fiber Roof SBS-TA, APP TA plywood staggered center H-Shield CG, Multi- Board APP TA APP TA rows Max FA3 Polyglass G2 Base, Elastobase, 32 ga., 1-5/8- 8-inch o.c. at min. (Optional) Min. 1.5- Min. 0.75-inch Fesco Elastobase P inch Polytherm, Board Min. (sanded -top), inch diameter 4-inch lap and 8- ACFoam II, Polytherm (homogeneous) or BP -AA (Optional) SBS-AA, W-8 19/32- Elastovent, tin caps with inch o.c. at three G, ACFoam III, ENRGY- Hot asphalt min. 0.5-inch Hot asphalt or SBS- BP -AA or SBS-TA, -60.0 inch CertainTeed 11 ga. annular (3), equally spaced, plywood Glasbase, Firestone ring shank staggered center 3, Polytherm H, H- Structodek High AA SBS-AA APP-TA MB Base, 1M Perma- Shield, H-Shield CG, Density Fiberboard Ply 28 or GAFGLAS nails rows Multi -Max FA3 Roof Insulation #75 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 6 of 94 NNEMO I etc. TABLE IB: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap Ply MDP (Psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Ply Polyglass G2 Base, Elastobase, 32 ga., 1-5/8- 8-inch o.c. at min. (Optional) Min. 1.5- Min. Elastobase P (sanded -top), inch diameter 4-inch lap and 8- inch Polytherm, Min. 0.25-inch BP -AA, (Optional) 19/32- Elastovent, tin caps with inch o.c. at three ACFoam II, Polytherm DensDeck Prime, SBS BP -AA, SBS SBS-AA, W-9 inch CertainTeed 11 ga. annular (3), equally spaced, G, ACFoam III, ENRGY- Hot asphalt SECUROCK Gypsum- Hot asphalt AA, AA, SBS-TA, SBS-TA, -60.0 plywood Glasbase, Firestone ring shank staggered center 3, Polytherm H, H- Fiber Roof Board SBS TA, APP-TA APP-TA MB Base, JM Perma- nails rows Shield, H-Shield CG, APP TA Ply 28 or GAFGLAS Multi -Max FA3 #75 12-inch o.c. at min. (Optional) Min. 1.5- Min. 0.75-inch Fesco Min. 4-inch lap and 12- inch Polytherm, Board 19/32- Elastobase, Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, (homogeneous) or BP -AA (Optional) SBS-AA, W-10 inch Elastobase P Cap Fasteners equally spaced, Polytherm H, H-Shield, Hot asphalt min. 0.5-inch Hot asphalt or SBS- BP -AA or SBS-TA, -60.0 plywood (sanded top) staggered center H-Shield CG, Multi- High AA SBS AA APP-TA rows Max FA3 Density Fib Density Fiberboard Roof Insulation 12-inch o.c. at min. (Optional) Min. 1.5- Min. 0.25-inch BP -AA, Min. Elastobase, 4-inch lap and 12- inch Polytherm, DensDeck, DensDeck SBS- (Optional) SBS-AA, W-11 19/32- Elastobase P Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, Hot asphalt Prime, SECUROCK Hot asphalt AA, BP -AA, SBS SBS-TA, -60.0 inch (sanded top) Cap Fasteners equally spaced, Polytherm H, H-Shield, Gypsum Fiber Roof SBS-TA, AA, SBS-TA, APP TA plywood staggered center H-Shield CG, Multi- Board APP-TA APP-TA rows Max FA3 32 ga., 1-5/8- 8-inch o.c. at min. (Optional) Min. 1.5- Min. Elastobase, inch diameter 4-inch lap and 8- inch Polytherm, Min. 0.25-inch(Optional) BP -AA, 15/32- Elastobase tin caps with inch o.c. at four (4), ACFoam II, ENRGY-3, DensDeck Prime, SBS- BP -AA, SBS SBS-AA, W-12 inch P(sanded-top) or 12 ga. annular equally spaced, Polytherm H, H-Shield, Hot asphalt SECUROCK Gypsum- Hot asphalt AA, AA, SBS-TA, SBS-TA, -67.5 plywood Elastovent ring shank staggered center H-Shield CG, Multi- Fiber Roof Board SBS-TA, APP TA APP TA nails rows Max FA3 APP-TA 9-inch o.c. at min. (Optional) Min. 1.5- Min. 4-inch lap and 9- inch Polytherm, Min. 0.25-inch(Optional) BP -AA, 15/32- Simplex MAXX inch o.c. at four (4), ACFoam II, ENRGY-3, DensDeck Prime, SBS- BP -AA, SBS- SBS-AA, W-13 inch Polyglass G2 Base Cap equally spaced, Polytherm H, H-Shield, Hot asphalt SECUROCK Gypsum- Hot asphalt AA, AA, SBS-TA, SBS-TA, -82.5 plywood staggered center H-Shield CG, Multi- Fiber Roof Board SBS-TA, APP TA APP-TA rows Max FA3 APP TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 7 of 94 NNEMO I etc. TABLE 113: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap Ply MDP (Psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Ply 32 ga., 1-5/8- 6-inch o.c. at min. (Optional) Min. 1.5- Min. Polyglass G2 Base, inch diameter 4-inch lap and 6- inch Polytherm, Min. 0.25-inch BP -AA, (Optional) 15/32- Elastobase, tin caps with inch o.c. at five (5) ACFoam II, ENRGY-3, DensDeck Prime, SBS- BP -AA, SBS- SBS-AA, W-14 Elastobase P Hot asphalt Hot asphalt AA, SBS-TA, -90.0 inch (sanded -top) or 12 ga. annular equally spaced, Polytherm H, H-Shield, SECUROCK Gypsum- SBS-TA, AA, SBS-TA, APP-TA plywood ring shank staggered center H-Shield CG, Multi- Fiber Roof Board APP TA nails rows Max FA3 APP TA 6-inch o.c. at min. (Optional) Min. 1.5- Min. 2-inch lap and 6- inch Polytherm, Min. 0.25-inch BP -AA, (Optional) 15/32- Elastobase, Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, DensDeck Prime, SBS- BP -AA, SBS- SBS-AA, W-15 inch Elastobase P Cap equally spaced, Polytherm H, H-Shield, Hot asphalt SECUROCK Gypsum- Hot asphalt AA, AA, SBS-TA, SBS-TA, -90.0 plywood (sanded -top) staggered center H-Shield CG, Multi- Fiber Roof Board SBS-TA, APP-TA APP-TA rows Max FA3 APP TA 32 ga., 1-5/8- 6-inch o.c. at min. Min. Elastobase, inch diameter 4-inch lap and 6- Min. 2-inch Polytherm, D-IS, OB500, Min. 0.25-inch D-IS, BP -AA, (Optional) 19/32- Elastobase P tin caps with inch o.c. at four (4), ACFoam II, III, CR-20 or M- DensDeck, DensDeck OB500, CR SBS- BP -AA, SBS- SBS-AA, W-16 inch (sanded -top) or 12 ga. annular equally spaced, Polytherm H, H-Shield, OSFA, atop Prime or SECUROCK 20 or M- AA, AA, SBS-TA, SBS-TA, -60.0* H-Shield CG, Multi- fastener rows, Gypsum -Fiber Roof SBS-TA, APP-TA plywood Elastovent ring shank staggered center Max FA3 or ENRGY-3 7-inch o.c. Board OSFA APP TA APP-TA nails rows SELF -ADHERING BASE PLY: 9-inch o.c. at min. (Optional) Min. 1.5- Min. 2-inch lap and 18- inch Polytherm, Min. 0.25-inch (Optional) SBS-SA, 15/32- Elastobase, Simplex MAXX inch o.c. at two, ACFoam II, ENRGY-3, DensDeck, DensDeck SBS-SA, APP-SA, W 17 Elastobase P Hot asphalt Prime, SECUROCK Hot asphalt SBS-SA 45.0* inch (sanded top) Cap equally spaced, Polytherm H, H-Shield, - Gypsum Fiber Fiber Roof SBS-TA, SBS-TA, plywood staggered center H-Shield CG, Multi- APP-TA APP-TA rows Max FA3 Board 9-inch o.c. at min. (Optional) Min. 1.5 Min. 0.25-inch Min. 2-inch lap and 12- inch Polytherm, (Optional) SBS-SA, 15/32- Elastobase, Simplex MAXX inch o.c. at two, ACFoam II, ENRGY-3, DensDeck, DensDeck SBS-SA, APP-SA, W 18 inch Elastobase P Cap equally spaced, Polytherm H, H-Shield, Hot asphalt Prime, SECUROCK Hot asphalt SBS SA SBS-TA, SBS-TA, 52.5 (sanded -top) - Gypsum -Fiber Fiber Roof plywood staggered center H-Shield CG, Multi- Board APP-TA APP-TA rows Max FA3 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 8 of 94 NNEMO I etc. TABLE IB: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap Ply MDP (Psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Ply Polyglass G2 Base, Elastobase, (Optional) Min. 1.5- Elastobase P 32 ga., 1-5/8- 8-inch o.c. at min. inch Polytherm, Min. 0.25-inch Min. (sanded -top), inch diameter 4-inch lap and 8- ACFoam II, Polytherm DensDeck, DensDeck (Optional) SBS-SA, W 19 19/32- Elastovent, tin caps with inch o.c. at three G, ACFoam III, ENRGY- Hot asphalt Prime, CK Hot asphalt SBS-SA SBS-SA, APP-SA, 60.0 inch CertainTeed 11 ga. annular (3), equally spaced, SBS-TA, SBS-TA, plywood Glasbase, Firestone ring shank staggered center 3, Polytherm H, H- -Fiber Gypsum -Fiber Roof APP-TA APP-TA MB Base, 1M Perma- nails rows Shield, H-Shield CG, Board Ply 28 or GAFGLAS Multi -Max FA3 #75 12-inch o.c. at min. (Optional) Min. 1.5- Min. 0.25-inch Min. 4-inch lap and 12- inch Polytherm, (Optional) SBS-SA, 19/32- Elastobase, Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, DensDeck, DensDeck SBS-SA, APP-SA, W 20 inch Elastobase P Cap Fasteners equally spaced, Polytherm H, H-Shield, Hot asphalt Prime, CK Hot asphalt SBS SA SBS-TA, SBS-TA, 60.0 (sanded -top) - Gypsum -Fiber Fiber Roof plywood staggered center H-Shield CG, Multi- APP-TA APP-TA rows Max FA3 Board 32 ga., 1-5/8- 6-inch o.c. at min. Min. inch diameter 4-inch lap and 6- Min. 2-inch Polytherm, D-IS, OB500, D-IS, (Optional) SBS-SA, 19/32- Elastobase, tin caps with inch o.c. at four (4), ACFoam II, III, CR-20 or M- (Optional) Additional OB500, CR- SBS-SA, APP-SA , W-21 Elastobase P Polytherm H, H-Shield, OSFA, atop layers of base SBS-SA -60.0* inch (sanded -top) 12 ga. annular equally spaced, Shield CG, Multi- fastener rows, insulation 20 or M- SBS-TA, SBS-TA, plywood ring shank staggered center M ax FA3 or ENRGY 3 M 7-inch o.c. OSFA APP-TA APP-TA nails rows HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: 9-inch o.c. at min. (Optional) Min. 1.5- Min. 2-inch lap and 18- inch Polytherm, Min. 0.25-inch 15/32- Elastobase, Simplex MAXX inch o.c. at two, ACFoam II, ENRGY-3, DensDeck, DensDeck APP- (Optional) W-22 Elastobase P Hot asphalt Prime, SECUROCK Hot asphalt APP-TA -45.0* inch (sanded -top) Cap equally spaced, Polytherm H, H-Shield, Gypsum -Fiber Roof SA-H APP-TA plywood staggered center H-Shield CG, Multi- rows Max FA3 Board 9-inch o.c. at min. (Optional) Min. 1.5 Min. Min. Elastobase, 2-inch lap and 12- inch Polytherm, Deck,inch DensDeck, DensDeck 15/32- Simplex MAXX inch o.c. at two, ACFoam II, ENRGY-3, APP- (Optional) W 23 inch Elastobase P Cap equally spaced, Polytherm H, H-Shield, Hot asphalt Prime, Hot asphalt SA-H APP-TA APP-TA 52.5 (sanded -top) -Fiber o Gypsum -Fiber Roof plywood staggered center H-Shield CG, Multi- Board rows Max FA3 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 9 of 94 NNEMO I etc. TABLE 113: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap Ply MDP (Psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Ply Polyglass G2 Base, Elastobase, (Optional) Min. 1.5- Elastobase P 32 ga., 1-5/8- 8-inch o.c. at min. inch Polytherm, Min. 0.25-inch Min. (sanded -top), inch diameter 4-inch lap and 8- ACFoam II, Polytherm DensDeck, DensDeck W 24 19/32- Elastovent, tin caps with inch o.c. at three G, ACFoam III, ENRGY- Hot asphalt Prime, Hot asphalt APP- (Optional) APP-TA 60.0 inch CertainTeed 11 ga. annular (3), equally spaced, SA-H APP-TA plywood Glasbase, Firestone ring shank staggered center 3, Polytherm H, H- - Roof Gypsum -Fiber RoFiber MB Base, 1M Perma- nails rows Shield, H-Shield CG, Board Ply 28 or GAFGLAS Multi -Max FA3 #75 12-inch o.c. at min. (Optional) Min. 1.5- Min. 0.25-inch Min. Elastobase, 4-inch lap and 12- inch Polytherm, DensDeck, DensDeck 19/32- Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, APP- (Optional) W 25 inch Elastobase P Cap Fasteners equally spaced, Polytherm H, H-Shield, Hot asphalt Prime, Hot asphalt SA-H APP-TA APP-TA 60.0 (sanded -top) -o Gypsum -Fiber Fiber Roof plywood staggered center H-Shield CG, Multi- rows Max FA3 Board 32 ga., 1-5/8- 8-inch o.c. at min. (Optional) Min. 1.5- Min. Polyglass G2 Base, inch diameter 4-inch lap and 8- inch Polytherm, Min. 0.25-inch 15/32- Elastobase, tin caps with inch o.c. at four (4), ACFoam II, ENRGY-3, DensDeck Prime, APP- (Optional) W 26 inch Elastobase P 12 ga. annular equally spaced, Polytherm H, H-Shield, Hot asphalt SECUROCK Gypsum- Hot asphalt SA-H APP-TA APP-TA 67.5 (sanded -to or plywood Elastoven ring shank staggered center H-Shield CG, Multi- Fiber Roof Board nails rows Max FA3 9-inch o.c. at min. (Optional) Min. 1.5- Min. 4-inch lap and 9- inch Polytherm, Min. 0.25-inch 15/32- Simplex MAXX inch o.c. at four (4), ACFoam II, ENRGY-3, DensDeck Prime, APP- (Optional) W 27 Polyglass G2 Base Hot asphalt Hot asphalt APP-TA 82.5 inch Cap equally spaced, Polytherm H, H-Shield, SECUROCK Gypsum- SA-H APP-TA plywood staggered center H-Shield CG, Multi- Fiber Roof Board rows Max FA3 32 ga., 1-5/8- 6-inch o.c. at min. (Optional) Min. 1.5- Polyglass G2 Base, Min. Elastobase, inch diameter 4-inch lap and 6- inch Polytherm, Min. 0.25-inch 15/32- tin caps with inch o.c. at five (5) ACFoam II, ENRGY-3, DensDeck Prime, APP- (Optional) W 28 inch Elastobase P 12 ga. annular equally spaced, Polytherm H, H-Shield, Hot asphalt SECUROCK Gypsum- Hot asphalt SA-H APP-TA APP-TA 90.0 (sanded -to or plywood Elastoven ring shank staggered center H-Shield CG, Multi- Fiber Roof Board nails rows Max FA3 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 10 of 94 NNEMO I etc. TABLE 113: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap Ply MDP (Psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Ply 6-inch o.c. at min. (Optional) Min. 1.5- Min. 2-inch lap and 6- inch Polytherm, Min. 0.25-inch 15/32- Elastobase, Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, DensDeck Prime, APP- (Optional) W 29 Elastobase P Hot asphalt Hot asphalt APP-TA 90.0 inch (sanded -top) Cap equally spaced, Polytherm H, H-Shield, SECUROCK Gypsum- SA-H APP-TA plywood staggered center H-Shield CG, Multi- Fiber Roof Board rows Max FA3 32 ga., 1-5/8- 6-inch o.c. at min. Min. inch diameter 4-inch lap and 6 Min. 2-inch Polytherm, D-IS, OB500, D-IS, 19/32- Elastobase, tin caps with inch o.c. at four (4), ACFoam II, III, CR-20 or M- (Optional) Additional OB500, CR- APP- (Optional) W-30 inch Elastobase P 12 ga. annular equally spaced, Polytherm H, H-Shield, OSFA, atop layers of base 20 or M- SA-H APP-TA APP-TA -60.0* (sanded -top) H-Shield CG, Multi- fastener rows, insulation plywood ring shank staggered center Max FA3 or ENRGY-3 7-inch o.c. OSFA nails rows HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: 9-inch o.c. at min. (Optional) Min. 1.5 Min. Min. Elastobase, 2-inch lap and 18- inch Polytherm, Deck,inch DensDeck, DensDeck 15/32- Simplex MAXX inch o.c. at two, ACFoam II, ENRGY-3, SBS-SA- (Optional) W-31 inch Elastobase P Cap equally spaced, Polytherm H, H-Shield, Hot asphalt Prime, Hot asphalt H SBS-TA SBS-TA 45.0* (sanded -top) -Fiber o Gypsum -Fiber Roof plywood staggered center H-Shield CG, Multi- Board rows Max FA3 9-inch o.c. at min. (Optional) Min. 1.5- Min. 2-inch lap and 12- inch Polytherm, Min. 0.25-inch 15/32- Elastobase, Simplex MAXX inch o.c. at two, ACFoam II, ENRGY-3, DensDeck, DensDeck SBS-SA- (Optional) W 32 Elastobase P Hot asphalt Prime, Hot asphalt SBS-TA 52.5 inch (sanded top) Cap equally spaced, Polytherm H, H-Shield, -o Gypsum Fiber Fiber Roof H SBS-TA plywood staggered center H-Shield CG, Multi- rows Max FA3 Board Polyglass G2 Base, Elastobase, 32 ga., 1-5/8- 8-inch o.c. at min. (Optional) Min. 1.5- Elastobase P inch Polytherm, Min. 0.25-inch Min. (sanded -top), inch diameter 4-inch lap and 8- ACFoam II, Polytherm DensDeck, DensDeck W-33 19/32- Elastovent, tin caps with inch o.c. at three G, ACFoam III, ENRGY- Hot asphalt Prime, SECUROCK Hot asphalt SBS-SA- (Optional) SBS-TA -60.0 inch CertainTeed 11 ga. annular (3), equally spaced, H SBS-TA plywood Glasbase, Firestone ring shank staggered center 3, Polytherm H, H- Gypsum -Fiber Roof MB Base, JM Perma- nails rows Shield, H-Shield CG, Board Ply 28 or GAFGLAS Multi -Max FA3 #75 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 11 of 94 NNEMO I etc. TABLE IB: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Cap Ply MDP (psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Ply 12-inch o.c. at min. (Optional) Min. 1.5- Min. 4-inch lap and 12- inch Polytherm, Min. 0.25-inch 19/32- Elastobase, Simplex MAXX inch o.c. at two (2), ACFoam II, ENRGY-3, DensDeck, DensDeck SBS-SA- (Optional) W-34 Elastobase P Hot asphalt Prime, Hot asphalt SBS-TA 60.0 inch (sanded -top) Cap Fasteners equally spaced, Polytherm H, H-Shield, -o Gypsum -Fiber Fiber Roof H SBS-TA plywood staggered center H-Shield CG, Multi- Board rows Max FA3 32 ga., 1-5/8- 6-inch o.c. at min. Min. inch diameter 4-inch lap and 6 Min. 2-inch Polytherm, D-IS, OB500, D-IS, 19/32- Elastobase, tin caps with inch o.c. at four (4), ACFoam II, III, CR-20 or M- (Optional) Additional OB500, CR- SBS-SA- (Optional) W-35 inch Elastobase P 12 ga. annular equally spaced, Polytherm H, H-Shield, OSFA, atop layers of base 20 or M- H SBS-TA SBS-TA -60.0* (sanded -top) H-Shield CG, Multi- fastener rows, insulation plywood ring shank staggered center Max FA3 or ENRGY-3 7-inch o.c. OSFA nails rows TABLE 1C: ••• •CONSTRUCTION,••• • • OR RECOVER SYSTEIMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) Deck System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Type Attach Base Ply Ply MDP Cap Ply I(psf) (Notes 6,7,8) (Notes 6,7,8) ASPHALT -APPLIED OR TORCH -APPLIED BASE PLY: Polyglass G2 Dekfast Hex (aka, Dekfast PLT-H-2- 10-inch o.c. at (Optional) Min. 1.5- Min. 0.25-inch Min. Base, 7/8) with Dekfast #14, OMG 3" min. 4-inch lap inch Polytherm, DensDeck, BP -AA, (Optional) 15/32- Elastobase, Round Metal Plate with OMG HD, and 10-inch D.C. ACFoam II, ENRGY- DensDeck Prime, SBS-AA, BP -AA, SBS- SBS-AA, W-36 OMG Flat Bottom Plate (Accutrac) at three (3), Hot asphalt Hot asphalt SBS-TA, -52.5 inch Elastobase P with Roofgrip #14 or Trufast 3" equally spaced, 3, Polytherm H, H- SECUROCK SBS-TA, AA, SBS-TA, APP-TA plywood (sanded -top) Metal Insulation Plate with Trufast staggered center Shield, H Shield CG, Gypsum -Fiber APP-TA APP-TA or Elastovent #14 HD. Multi -Max FA3 Roof Board rows 12-inch o.c. at Min. 0.75-inch (Optional) Min. 1.5- Fesco Board Min. Elastobase, min. 4-inch lap inch Polytherm, (homogeneous) 19/32- Elastobase P OMG Flat Bottom Plates and 12-inch o.c. ACFoam II, ENRGY- or min. 0.5-inch BP -AA or (Optional) SBS-AA, W-37 at two (2), Hot asphalt Hot asphalt BP -AA or SBS-TA, -60.0 inch (sanded -top) (square) with Roofgrip #12 3, Polytherm H, H- Structodek High SBS-AA plywood or Elastovent equally spaced, Shield, H-Shield CG, Density SBS-AA APP-TA staggered center Multi -Max FA3 Fiberboard Roof rows Insulation NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 12 of 94 NNEMO I etc. TABLE IC: ....REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System No. Note 1 ( ) T Type Note 11 Fasten ( ) Attach yP Type Attach Type Attach Base PI y PI y Ca P Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) 12-inch o.c. at (Optional) Min. 1.5- Min. 0.25-inch min. 4-inch lap Min. Elastobase, and 12-inch o.c. inch Polytherm, DensDeck, BP -AA, (Optional) SBS-AA, 19/32- Elastobase P OMG Flat Bottom Plates ACFoam II, ENRGY- DensDeck Prime, SBS-AA, BP -AA, SBS- W-38 inch (sanded -top) (square) with Roofgrip #12 at two (2), 3, Polytherm H, H- Hot asphalt SECUROCK Hot asphalt SBS-TA, AA, SBS-TA, SBS-TA, -60.0 plywood or Elastovent equally spaced, Shield, H-Shield CG, Gypsum -Fiber APP-TA APP-TA APP-TA staggered center Multi -Max FA3 Roof Board rows Polyglass G2 Hex aka, Dekfast PLT-H-2- Dekfast ( 9-inch o.c. at (Optional) Min. 1.5- Min. 0.25-inch Min. Base, 7/8) with Dekfast #14, OMG 3" min. 4-inch lap inch Polytherm, DensDeck, BP -AA, (Optional) 15/32- Elastobase, Round Metal Plate with OMG HD, and 9-inch o.c. at ACFoam II, ENRGY- DensDeck Prime, SBS-AA, BP -AA, SBS- SBS-AA, W-39 inch Elastobase P OMG Flat Bottom Plate (Accutrac) four (4), equally 3, Polytherm H, H- Hot asphalt SECUROCK Hot asphalt SBS-TA, AA, SBS-TA SBS-TA, -82.5 with Roofgrip #14 or Trufast 3" spaced, , APP-TA plywood (sanded -top) Metal Insulation Plate with Trufast staggered center Shield, H-Shield CG, Gypsum -Fiber APP-TA APP-TA or Elastovent #14 HD. Multi -Max FA3 Roof Board rows SELF -ADHERING BASE PLY: 12-inch o.c. at (Optional) Min. 1.5- Min. 0.25-inch Min. Elastobase, min. 4-inch lap inch Polytherm, DensDeck, (Optional) SBS-SA, 19/32- Elastobase P OMG Flat Bottom Plates and 12-inch o.c.ACFoam II, ENRGY- DensDeck Prime, SBS-SA, APP-SA, W-40 at two (2), Hot asphalt Hot asphalt SBS-SA -60.0 inch (sanded -top) (square) with Roofgrip #12 equally spaced, 3, Polytherm H, H- SECUROCK SBS-TA, SBS-TA, plywood or Elastovent staggered center Shield, H-Shield CG, Gypsum -Fiber APP-TA APP-TA Multi -Max FA3 Roof Board rows HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Polyglass G2 Dekfast Hex (aka, Dekfast PLT-H-2- 10-inch o.c. at (Optional) Min. 1.5- Min. 0.25-inch Min. Base, 7/8) with Dekfast #14, OMG 3" min. 4-inch lap inch Polytherm, DensDeck, 15/32- Elastobase, Round Metal Plate with OMG HD, and 10-inch o.c. ACFoam II, ENRGY- DensDeck Prime, (Optional) W-41 inch Elastobase P OMG Flat Bottom Plate (Accutrac) at three (3), 3, Polytherm H, H- Hot asphalt SECUROCK Hot asphalt APP-SA-H APP-TA APP-TA -52.5 with Roofgrip #14 or Trufast 3" equally spaced, plywood (sanded -top) Metal Insulation Plate with Trufast staggered center Shield, H Shield CG, Gypsum Fiber or Elastovent #14 HD. Multi -Max FA3 Roof Board rows 12-inch o.c. at (Optional) Min. 1.5- Min. 0.25-inch Min. Elastobase, min. 4-inch lap inch Polytherm, DensDeck, 19/32- Elastobase P OMG Flat Bottom Plates and 12-inch o.c.ACFoam II, ENRGY- DensDeck Prime, (Optional) W-42 inch (sanded -top) (square) with Roofgrip #12 at two (2), 3, Polytherm H, H- Hot asphalt SECUROCK Hot asphalt APP-SA-H APP-TA APP-TA -60.0 plywood or Elastovent equally spaced, Shield, H-Shield CG, Gypsum -Fiber staggered center Multi -Max FA3 Roof Board rows NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 13 of 94 NNEMO etc. TABLE IC: DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEIVITYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System Deck MDP No. Note 1 T Note 11 Attach Type Attach Type y y P Ply Attach Base PI PI Ca (psf) ( ) Type Fasten ( ) YP (Notes 6,7,8) (Notes 6,7,8) Hex aka, Dekfast PLT-H-2- 9-inch o.c. at Polyglass G2 Dekfast ( (Optional) Min. 1.5- Min. 0.25-inch 7/8) with Dekfast #14, OMG 3" min. 4-inch lap Min. Base, inch Polytherm, DensDeck, 15/32- Elastobase, Round Metal Plate with OMG HD, and 9-inch D.C. at ACFoam II, ENRGY- DensDeck Prime, (Optional) W-43 OMG Flat Bottom Plate (Accutrac) four (4), equally Hot asphalt Hot asphalt APP-SA-H APP-TA -82.5 with Roofgrip #14 or Trufast 3" inch Elastobase P spaced 3, Polytherm H, H- SECUROCK APP-TA , plywood (sanded -top) Metal Insulation Plate with Trufast staggered center Shield, H-Shield CG, Gypsum -Fiber or Elastovent #14 HD. Multi -Max FA3 Roof Board rows HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: 12-inch o.c. at min4-inch lap (Optional) Min. 1.5- Min. 0.25-inch . Min. Elastobase, inch Polytherm, DensDeck, 19/32- Elastobase P OMG Flat Bottom Plates and 12-inch o.c.ACFoam II, ENRGY- DensDeck Prime, (Optional) inch (sanded -top) (square) with Roofgrip #12 3, Polytherm H, H- SECUROCK SBS-TA W-44 at two (2), Hot asphalt Hot asphalt SBS-SA-H SBS-TA -60.0 plywood or Elastovent equally spaced, Shield, H-Shield CG, Gypsum -Fiber staggered center Multi -Max FA3 Roof Board rows TABLE 11): WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVE�& Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) Deck System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Base Ply Ply M DP Cap Ply (psf) (Notes 6,7,8) ASPHALT -APPLIED OR TORCH -APPLIED BASE PLY: Min. 32- 19 / Dekfast Hex (aka, Dekfast PLT-H- Min. 0.75-inch Fesco Board (Optional if (Optional if using AA SBS-AA, W-45 inch Min. 1.5-inch ENRGY 3, 2-7/8) with Dekfast #12 or Trufast 1 per (homogeneous) or min. 0.5-inch Hot asphalt using AA Ply) Base) BP -AA, SBS-AA, SBS-TA, -60.0 H-Shield or Polytherm 3" Metal Insulation Plate with 1.3 ft2 Structodek High Density plywood Trufast DP T Fiberboard Roof Insulation BP-AA, SBS-AA SBS-TA or APP-TA APP-TA Min. 2-inch Polytherm, Dekfast #14 with Dekfast Hex Min. 15/32- ACFoam II, ENRGY-3, (aka, Dekfast PLT-H-2-7/8), OMG Min. 0.25-inch DensDeck Prime SBS-AA, W-46 inch EnergyGuard Polyiso #14 HD with OMG 3" Galvalume 1 per or SECUROCK Gypsum Fiber Roof Hot asphalt SBS-AA, SBS- (Optional) SBS-AA, SBS-TA, -75.0 Steel Plates or Trufast #14 HD 1.0 ft Z TA, APP-TA SBS-TA, APP-TA plywood Insulation, H-Shield or With Trufast 3-inch Insulation Board APP-TA Multi -Max FA3 Plates HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for FL1654-R27 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 14 of 94 NNEMO I etc. Deck TABLE 1D: ....REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER 11�01 Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) Min. 2-inch Polytherm, Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8), OMG Min. 15/32- ACFoam II, ENRGY-3, Min. 0.25-inch DensDeck Prime #14 HD with OMG 3" Galvalume 1 per W-47 inch EnergyGuard Polyiso Steel Plates or Trufast #14 HD Z 1.0 ft or SECUROCK Gypsum Fiber Roof Hot asphalt APP-SA-H (Optional) APP-TA APP-TA -75.0 plywood Insulation, H-Shield or Board Multi -Max FA3 with Trufast 3-inch Insulation Plates L TABLE IE: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER r, SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. (Note 1) (Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf) ASPHALT -APPLIED OR TORCH -APPLIED BASE PLY: (Optional) One or Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32- more layers, any Min. 0.25-inch DensDeck Prime or Dekfast #14, OMG 3" Round Metal Plate with 1 per BP -AA, SBS- (Optional) BP - SBS-AA, SBS- W-48 inch combination, loose SECUROCK Gypsum -Fiber Roof OMG HD, OMG Flat Bottom Plate (Accutrac) with 2.0 ft2 AA, SBS-TA, AA, SBS-AA, TA, APP-TA -30.0 plywood laid Board Roofgrip #14 or Trufast 3" Metal Insulation Plate APP-TA SBS-TA, APP-TA with Trufast #14 HD. Min. 15/32- (Optional) One or Min. 0.25-inch DensDeck Prime or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H (Optional) SBS- W-49 inch more layers, any SECUROCK Gypsum -Fiber Roof 2-7/8), OMG #14 HD with OMG 3" Galvalume 1 per SBS-AA, SBS- AA, SBS-TA, SBS-AA, SBS- -45.0 combination, loose Steel Plates or Trufast #14 HD with Trufast 3-inch 1.8 ft 2 TA, APP-TA TA, APP-TA plywood laid Board Insulation Plates APP TA Min. 15/32- (Optional) One or Min. 0.25-inch DensDeck Prime or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H- (Optional) SBS- W-50 inch more layers, any SECUROCK Gypsum -Fiber Roof 2-7/8), OMG #14 HD with OMG 3" Galvalume 1 per SBS-AA, SBS- AA, SBS-TA, SBS-AA, SBS- -75.0 plywood combination, loose Board Steel Plates or Trufast #14 HD with Trufast 3-inch 1.0 ft Z TA, APP-TA APP TA TA, APP-TA laid Insulation Plates (Optional) One or Min. 0.5-inch Structodek High (Optional if (Optional if Min. 19/32- more layers, any Density Fiberboard Roof Insulation Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 1 per using AA Ply) using AA Base) SBS-AA, SBS- W-51 inch combination, loose or min. 0.25-inch DensDeck, Dekfast #12 DP 1.3 ft2 BP -AA, SBS- BP -AA, SBS-AA, TA, APP-TA -82.5 plywood laid DensDeck Prime or SECUROCK AA SBS-TA or APP- Gypsum -Fiber Roof Board TA SELF -ADHERING BASE PLY: Min. 15/32- (Optional) One or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H (Optional)SBS- SBS-SA,APP- more layers, any Min. 1.5-inch Polytherm, ACFoam II, 2-7/8), OMG #14 HD with OMG 3" Galvalume 1 per W-52 inch combination, loose H-Shield or Polytherm Steel Plates or Trufast #14 HD with Trufast 3-inch 2.7 ftz SBS-SA SA, SBS-TA, SA, SBS-TA, -30.0 plywood laid Insulation Plates APP-TA APP-TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 15 of 94 NNEMO I etc. TABLE IE: ....REROOF (TEAR -OFF) OR RECOVER BONDEDL SYSTEIVITYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP Base Ply Ply Cap Ply No. (Note 1) (Note 13) Type Fasten (Note 11) Attach (psf) (Optional) One or Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32- more layers, any Min. 0.25-inch DensDeck Prime or Dekfast #14, OMG 3" Round Metal Plate with (Optional) SBS- SBS-SA, APP- W-53 inch combination, loose SECUROCK Gypsum -Fiber Roof OMG HD, OMG Flat Bottom Plate (Accutrac) with .per 2.0 ftZ SBS-SA SA, SBS-TA, SA, SBS-TA, -30.0 plywood laid Board Roofgrip #14 or Trufast 3" Metal Insulation Plate APP-TA APP-TA with Trufast #14 HD. Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) Min. 15/32- One or more layers, Min. 0.25-inch SECUROCK Gypsum- or Dekfast Galvalume Steel 3" Round (aka, Dekfast W-54 inch any combination, min. Fiber Roof Board optionally primed pLT-R-3) or OMG #14 Roofgrip with OMG 3 in. 1 per SBS-SA None SBS-SA -45.0 plywood 1-inch, loose laid with POLYBRITE 745 or WB3000 Round Metal Plate, OMG 3 in. Ribbed Galvalume Z 2.0 ft Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plate Polygrip #14 with Polygrip Hex Plate or Dekfast Min. 15/32- One or more layers, Min. 0.25-inch DensDeck Prime #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) W-55 inch any combination, min. optionally primed with POLYBRITE or OMG #14 Roofgrip with OMG 3 in. Round Metal 1 perZ SBS-SA None SBS-SA -45.0 plywood 1-inch, loose laid 745 or WB3000 Plate or Accutrac Flat Bottom Plate or Trufast #14 2.0 ft HD Fasteners with Trufast 3" Metal Insulation Plate Polygrip #14 with Polygrip Hex Plate or Dekfast Min. 15/32- One or more layers, Min. 0.25-inch SECUROCK Gypsum- DF-#14 with Dekfast Hex (aka, Dekfast PLT-H-2- (Optional when SBS-SA, APP- W-56 inch any combination, min. Fiber Roof Board optionally primed 7/8) or OMG #14 Roofgrip with OMG 3 in. Round 1 per SBS-SA using torch- SA, SBS-TA or -45.0 plywood 1-inch, loose laid with POLYBRITE 745 or WB3000 Metal Plate or Accutrac Flat Bottom Plate or 1.8 ft z applied Cap Ply) APP TA Trufast #14 HD Fasteners with Trufast 3" Metal SBS-TA, APP-TA Insulation Plate Min. 15/32- One or more layers, Min. 0.25-inch DensDeck Prime OMG #14 Roofgrip with OMG 3 in. Round Metal (Optional when SBS-SA, APP- W-57 inch any combination, min. optionally primed with POLYBRITE Plate or Trufast #14 HD Fasteners with Trufast 3" 1 per 2 1.8 ft SBS-SA using torch- applied Cap Ply) SA, SBS-TA or -45.0 plywood 1-inch, loose laid 745 or WB3000 Metal Insulation Plate APP TA SBS-TA, APP-TA Min. 15/32- (Optional) One or Min. 0.25-inch DensDeck Prime, Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H- more layers, any DEXcell FA Glass Mat Roof Board or 2-7/8), OMG #14 HD with OMG 3" Galvalume 1 per (Optional) SBS- SBS-TA, APP- W-58 inch combination, loose SECUROCK Gypsum -Fiber Roof Steel Plates or Trufast #14 HD with Trufast 3-inch 1.0 ft2 SBS-SA TA, APP-TA TA -60.0 plywood laid I Board IInsulation Plates NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 16 of 94 NNEMO I etc. TABLE IE: ....REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEIVITYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. (Note 1) (Note 13) (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply APA rated, Min. 1.5-inch ACFoam II, ACFoam III, 19/32 CAT, EnergyGuard Polyiso Insulation, 0.578 in., (Optional) One or ENRGY 3, ENRGY 3 CGF, H-Shield, H- Trufast Versa Fasteners (min. %" penetration) & (Optional) SBS- SBS-SA, APP- Exposure 1 more layers, any Shield CG, ISO 95+ GL, Multi -Max Plates; 2 screws per plate installed 180°into the 1 per SBS-SA SA, SBS-TA, SA, SBS-TA, -67.5* W-59 OSB or min. combination, loose FA3, Polytherm or Ultra -Max holes of the plate* Z 1.3 ft APP-TA APP-TA 19/32" APA laid rated optionally primed with POLYBRITE plywood 745 or WB3000 Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 180lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance Min. 1.5-inch ACFoam II, ACFoam III, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast (Optional) One or EnergyGuard Polyiso Insulation, Galvalume Steel 3" Round Insulation Plate (aka, Min. 19/32- more layers, any ENRGY 3, ENRGY 3 CGF, H-Shield, H- Dekfast PLT-R-3) with Dekfast #12, OMG 3 in. 1 per (Optional) SBS- SBS-SA, APP- W-60 inch combination, loose Shield CG, ISO 95+ GL, Multi -Max Galvalume Plate (non -ribbed) or OMG AccuTrac 1.3 ftZ SBS-SA SA, SBS-TA, SA, SBS-TA, -67.5* plywood laid FA3, Polytherm or Ultra -Max Plate with #12 Roofgrip or Trufast 3" Metal gpp_TA APP-TA optionally primed with POLYBRITE Insulation Plate with Trufast DP 745 or WB3000 HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 15/32- (Optional) One or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H- more layers, any Min. 1.5-inch Polytherm, ACFoam II, 2-7/8), OMG #14 HD with OMG 3" Galvalume 1 per (Optional) APP- W-61 inch combination, loose H-Shield or Polytherm Steel Plates or Trufast #14 HD with Trufast 3-inch 2.7 ftz APP-SA-H TA APP-TA -30.0 plywood laid Insulation Plates (Optional) One or Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32- more layers, any Min. 0.25-inch DensDeck Prime or Dekfast #14, OMG 3" Round Metal Plate with 1 per (Optional) APP- W-62 inch combination, loose SECUROCK Gypsum -Fiber Roof OMG HD, OMG Flat Bottom Plate (Accutrac) with 2.0 ftz APP-SA-H TA APP-TA -30.0 plywood laid Board Roofgrip #14 or Trufast 3" Metal Insulation Plate with Trufast #14 HD. Min. 15/32- (Optional) One or Min. inch DensDeck Prime or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H- W-63 inch more layers, any ROCOCK Gypsum -Fiber Roof 2-7/8) OMG #14 HD with OMG 3" Galvalume 1 per APP-SA-H (Optional) APP- APP TA 45.0 plywood combination, loose B Board Steel Plates or Trufast #14 HD with Trufast 3-inch 1.8 ftz TA laid Insulation Plates HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 15/32- (Optional) One or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H- more layers, any Min. 1.5-inch Polytherm, ACFoam II, 2-7/8), OMG #14 HD with OMG 3" Galvalume 1 per (Optional) SBS- W-64 inch combination, loose H-Shield or Polytherm H Steel Plates or Trufast #14 HD with Trufast 3-inch 2.7 ft2 SBS-SA-H TA SBS-TA 30.0 plywood laid Insulation Plates NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 17 of 94 NNEMO I etc. TABLE IE: ....REROOF (TEAR -OFF) OR RECOVER BONDEDL SYSTEIVITYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP Base Ply Ply Cap Ply No. (Note 1) (Note 13) Type Fasten (Note 11) Attach (psf) (Optional) One or Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32- more layers, any Min. 0.25-inch DensDeck Prime or Dekfast #14, OMG 3" Round Metal Plate with 1 per (Optional) SBS- W-65 inch combination, loose SECUROCK Gypsum -Fiber Roof OMG HD, OMG Flat Bottom Plate (Accutrac) with 2.0 ftZ SBS-SA-H TA SBS-TA -30.0 plywood laid Board Roofgrip #14 or Trufast 3" Metal Insulation Plate with Trufast #14 HD. Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) Min. 15/32- One or more layers, Min. 0.25-inch SECUROCK Gypsum- or Dekfast Galvalume Steel 3" Round (aka, Dekfast W-66 inch any combination, min. Fiber Roof Board optionally primed pLT-R-3) or OMG #14 Roofgrip with OMG 3 in. 1 per SBS-SA-H (Optional) SBS- SBS-TA -45.0 plywood 1-inch, loose laid with POLYBRITE 745 or WB3000 Round Metal Plate, OMG 3 in. Ribbed Galvalume Z 2.0 ft TA Plate (Flat) or Accutrac Flat Bottom Plate or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plate Polygrip #14 with Polygrip Hex Plate or Dekfast Min. 15/32- One or more layers, Min. 0.25-inch DensDeck Prime #14 with Dekfast Hex (aka, Dekfast PLT-H-2-7/8) W-67 inch any combination, min. optionally primed with POLYBRITE or OMG #14 Roofgrip with OMG 3 in. Round Metal 1 per SBS-SA-H (Optional) SBS- SBS-TA -45.0 plywood 1-inch, loose laid 745 or WB3000 Plate or Accutrac Flat Bottom Plate or Trufast #14 Z 2.0 ft TA HD Fasteners with Trufast 3" Metal Insulation Plate Min. 15/32- (Optional) One or Min. 0.25-inch DensDeck Prime, Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H- more layers, any DEXcell FA Glass Mat Roof Board or 2-7/8), OMG #14 HD with OMG 3" Galvalume 1 per (Optional) SBS- W-68 inch combination, loose SECUROCK Gypsum -Fiber Roof Steel Plates or Trufast #14 HD with Trufast 3-inch 1.0 ft, SBS-SA-H TA SBS-TA 60.0 plywood laid Board Insulation Plates APA rated, Min. 1.5-inch ACFoam II, ACFoam III, 19/32 CAT, 0.578 in., (Optional) One or EnergyGuard Polyiso Insulation, Exposure 1 more layers, any ENRGY 3, ENRGY 3 CGF, H-Shield, H- Trufast Versa Fasteners (min. %" penetration) & 1 per (Optional) SBS- OSB or min. combination, loose Shield CG, ISO 95+ GL, Multi -Max Plates; 2 screws per plate installed 180' into the 1.3 ft SBS-SA-H TA SBS-TA -67.5* W-69 19/32" APA laid FA3, Polytherm or Ultra -Max holes of the plate* rated optionally primed with POLYBRITE plywood 745 or WB3000 Note: For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 180lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 18 of 94 NNEMO I etc. System No. Deck Base Insulation Layer (Note 1) (Note 13) TABLE IE: ....REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEIVITYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF COVER Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply Min. 1.5-inch ACFoam II, ACFoam III, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast (Optional) One or EnergyGuard Polyiso Insulation, Galvalume Steel 3" Round Insulation Plate (aka, Min. 19/32- more layers, any ENRGY 3, ENRGY 3 CGF, H-Shield, H- Dekfast PLT-R-3) with Dekfast #12, OMG 3 in. 1 per (Optional) SBS- W-70 inch combination, loose Shield CG, ISO 95+ GL, Multi -Max Galvalume Plate (non -ribbed) or OMG AccuTrac 1.3 ft2 SBS-SA-H TA SBS-TA -67.5* plywood laid FA3, Polytherm or Ultra -Max Plate with #12 Roofgrip or Trufast 3" Metal optionally primed with POLYBRITE Insulation Plate with Trufast D P 745 or WB3000 TABLE 1F: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER L SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP Deck (Note 1) (Note 13) No. Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply (Psf) ASPHALT -APPLIED OR TORCH -APPLIED BASE PLY: Elastobase, Elastobase P, Elastovent, OMG Flat Bottom Plates (square) with Roofgrip Min. 19/32-inch One or more Prelim. Polyglass G2 Base, #14, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 12-inch o.c. at min. 4-inch lap and (Optional) BP - SBS-AA, SBS- W-71 plywood layers, any Attached CertainTeed Dekfast or Trufast 3" Metal Insulation Plate 12-inch o.c. at two (2), equally AA, SBS-AA, SBS- TA, APP-TA -52.5 combination Glasbase, Firestone with Trufast as t #14 HD spaced, staggered center rows TA or APP-TA MB Base, JM Perma- Ply 28 or GAFGLAS #75 Min. 19/32-inch One or more Prelim. Elastobase, OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and (Optional) BP SBS-AA, SBS- W 72 layers, any Elastobase P or 12-inch o.c. at two (2), equally AA, SBS-AA, SBS- -60.0 plywood combination Attached Elastovent #12 spaced, staggered center rows TA or APP-TA TA, APP-TA APA rated, 19/32 CAT, 0.578 in., One or more Elastobase, Trufast Versa Fasteners (min. %" penetration) & 12-inch o.c. at min. 4-inch lap and SBS-SA, APP- Exposure 1 OSB or layers, any Loose -laid Elastobase P or Plates; 2 screws per plate installed 180° into the 12-inch o.c. at two (2), equally BP -AA, SBS-AA, SA, SBS-AA, -67.5 W-73 min. 19/32" APA combination Elastovent holes of the plate, parallel to the width -direction spaced, staggered center rows SBS-TA, APP-TA SBS-TA, APP- of the sheet* TA rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 19 of 94 NNEMO I etc. MEOW- ....REROOF (TEAR -OFF) OR RECOVER SYS EM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF System Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP Deck (Note 1) (Note 13) No. (Psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., One or more Plates; 2 screws per plate installed into the 12-inch o.c. at min. 4-inch lap and Exposure 1 OSB or layers, any Loose -laid Polyglass Base holes of the plate, parallel to the width -direction 12-inch o.c. at two (2), equally APP-TA APP-TA -67.5 W-74 min. 19/32" APA combination of the sheet* P staggered spaced, sta ered center rows rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance Polyglass G2 Base, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch One or more Prelim. Elastobase, Dekfast #14, OMG 3" Round Metal Plate with 10-inch o.c. at min. 4-inch lap and (Optional) BP - SBS-AA, SBS- W-75 plywood layers, any Attached Elastobase P or OMG HD, OMG Flat Bottom Plate (Accutrac) with 10-inch o.c. at three (3), equally AA, SBS-AA, SBS- TA, APP-TA -75.0 combination Elastovent Roofgrip #14 or Trufast 3" Metal Insulation Plate spaced, staggered center rows TA or APP-TA with Trufast #14 HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch One or more Prelim. Dekfast #14, OMG 3" Round Metal Plate with 10-inch o.c. at min. 4-inch lap and (Optional) APP- W-76 plywood layers, any Attached Polyglass Base OMG HD, OMG Flat Bottom Plate (Accutrac) with 10-inch o.c. at three (3), equally TA APP-TA -75.0 combination Roofgrip #14 or Trufast 3" Metal Insulation Plate spaced, staggered center rows with Trufast #14 HD. APA rated, 7/16 Trufast Versa Fasteners (min. %" penetration) & SBS-SA, APP- CAT, 0.418 in., One or more Elastobase, Plates; 2 screws per plate installed 180° into the 9-inch o.c. at min. 2-inch lap and BP -AA, SBS-AA, SA, SBS-AA, Exposure 1 OSB or layers, any Loose -laid Elastobase P or holes of the plate, parallel to the width -direction 12-inch o.c. at two (2), equally SBS-TA, APP-TA SBS-TA, APP- -90.0 W-77 min. 15/32" APA combination Elastovent of the sheet* spaced, staggered center rows TA rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 159lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance APA rated, 7/16 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.418 in., One or more Plates; 2 screws per plate installed into the 9-inch o.c. at min. 2-inch lap and Exposure 1 OSB or layers, any Loose -laid Polyglass Base holes of the plate, parallel to the width -direction 12-inch o.c. at two (2), equally APP-TA APP-TA -90.0 W-78 min. 15/32" APA combination of the sheet* P staggered spaced, sta ered center rows rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 159lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch One or more Prelim. Polyglass G2 Base, Elastobase, Dekfast #14, OMG 3" Round Metal Plate with 9-inch o.c. at min. 4-inch lap and (Optional) BP - SBS-AA, SBS- W-79 plywood layers, any Attached Elastobase P or OMG HD, OMG Flat Bottom Plate (Accutrac) with 9-inch o.c. at four (4), equally AA, SBS-AA, SBS- TA, APP TA 90.0 combination Elastovent Roofgrip #14 or Trufast 3" Metal Insulation Plate spaced, staggered center rows TA or APP-TA with Trufast #14 HD. NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 20 of 94 NNEMO I etc. MEOW- ....REROOF (TEAR -OFF) OR RECOVER SYS EM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF System Insulation Layer(s) Base Sheet Roof Cover (Note 15) MDP Deck (Note 1) (Note 13) No. (Psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch One or more Prelim. Dekfast #14, OMG 3" Round Metal Plate with 9-inch o.c. at min. 4-inch lap and (Optional) APP- W-80 plywood layers, any Attached Polyglass Base OMG HD, OMG Flat Bottom Plate (Accutrac) with 9-inch o.c. at four (4), equally TA APP-TA -90.0 combination Roofgrip #14 or Trufast 3" Metal Insulation Plate spaced, staggered center rows with Trufast #14 HD. Min. 15/32-inch One or more Prelim. Elastobase, Trufast #12 DP or Trufast #14 HD with Trufast 3" 6-inch o.c. at min. 4-inch lap and (Optional) BP -AA W 81 layers, any Elastobase P or 6-inch o.c. at three (3), equally SBS-AA -90.0 plywood combination Attached Elastovent Metal Insulation Plates spaced, staggered center rows or SBS-AA Min. 15/32-inch One or more Prelim. Elastobase, OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and (Optional) BP - SBS-AA, SBS- W 82 layers, any Elastobase P or Duty with OMG 3" Round Metal Plates or OMG 6-inch o.c. at three (3), equally AA, SBS-AA, SBS- 90.0 plywood combination Attached Elastovent Flat Bottom Metal Plates spaced, staggered center rows TA, APP-TA TA or APP-TA Min. 15/32-inch One or more Prelim. OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and (Optional) APP- W 83 layers, any Polyglass Base Duty with OMG 3" Round Metal Plates or OMG 6-inch o.c. at three (3), equally APP-TA -90.0 plywood combination Attached Flat Bottom Metal Plates spaced, staggered center rows TA APA rated, 7/16 CAT, 0.418 in., One or more Elastobase, Trufast Versa Fasteners (min. %" penetration) & 6-inch o.c. at min. 4-inch lap and SBS-SA, APP- Exposure 1 OSB or layers, any Loose -laid Elastobase P or Plates; 2 screws per plate installed 180° into the 6-inch o.c. at three (3), equally BP -AA, SBS-AA, SA, SBS-AA, -105.0 W-84 min. 15/32" APA combination Elastovent holes of the plate, parallel to the width -direction spaced, staggered center rows SBS-TA, APP-TA SBS-TA, APP- of the sheet* TA rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 103 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance APA rated, 7/16 CAT, 0.418 in., One or more Trufast Versa Fasteners (min. %" penetration) & 6-inch o.c. at min. 4-inch lap and Exposure 1 OSB or layers, any Loose -laid Polyglass Base Plates; 2 screws per plate installed into the 6-inch o.c. at three (3), equally APP-TA APP-TA -105.0 VV-85 min. 15/32" APA combination holes of the plate, parallel to the width -direction P staggered spaced, sta ered center rows of the sheet* rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 103 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance Min. 15/32-inch One or more Prelim Elastobase, Trufast #12 DP or Trufast #14 HD with Trufast 3" 6-inch o.c. at min. 4-inch lap and (Optional) BP -AA W 86 layers, any Elastobase P or 6-inch o.c. at five (5), equally SBS-AA -120.0 plywood combination Attach.ed Elastovent Metal Insulation Plates spaced, staggered center rows or SBS-AA Min. 15/32-inch One or more Prelim. Elastobase, OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and (Optional) BP - SBS-AA, SBS- W 87 layers, any Elastobase P or Duty with OMG 3" Round Metal Plates or OMG 6-inch o.c. at five (5), equally AA, SBS-AA, SBS- -120.0 plywood combination Attached Elastovent Flat Bottom Metal Plates spaced, staggered center rows TA, APP-TA TA or APP-TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 21 of 94 NNEMO I etc. ....REROOF (TEAR -OFF) OR RECOVER MEOW- SYS EM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF Insulation Layer(s) System Base Sheet Roof Cover (Note 15) MDP Deck (Note 1) (Note 13) No. (Psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply Min. 15/32-inch One or more Prelim. OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and (Optional) APP- W 88 layers, any Polyglass Base Duty with OMG 3" Round Metal Plates or OMG 6-inch o.c. at five (5), equally APP-TA -120.0 plywood combination Attached Flat Bottom Metal Plates TA spaced, staggered center rows SELF -ADHERING BASE PLY: Min. 19/32-inch One or more Prelim. Elastobase, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 12-inch o.c. at min. 4-inch lap and SBS-SA, APP- W 89 plywood layers, any Attached Elastobase P (poly- Dekfast #14 or Trufast 3" Metal Insulation Plate 12-inch o.c. at two, equally SBS-SA SA, SBS-TA -52.5* combination film top) with Trufast #14 HD spaced, staggered center rows or APP-TA Min. 19/32-inch One or more Prelim. Elastobase, OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and SBS-SA, APP- W 90 layers, any Elastobase P (poly- 12-inch o.c. at two, equally SBS-SA SA, SBS-TA -60.0* plywood combination Attached film top) #12 spaced, staggered center rows or APP-TA APA rated, 19/32 CAT, 0.578 in., One or more Elastobase, Trufast Versa Fasteners (min. %" penetration) & 12-inch o.c. at min. 4-inch lap and SBS-SA, APP- Exposure 1 OSB or layers, any Loose -laid Elastobase P (poly- Plates; screws per plate installed into the 12-inch o.c. at two (2), equally SBS-SA SA, SBS-TA, -67.5 W-91 min. 19/32" APA combination film top) holes off the plate, parallel to the width -direction spaced, staggered center rows APP-TA rated plywood of the sheet* Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 19/32 inch One or more Prelim. Elastobase, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 12-inch o.c. at min. 4-inch lap and W 92 layers, any Elastobase P (poly- Dekfast #14 or Trufast 3" Metal Insulation Plate 12-inch o.c. at two, equally APP-SA-H APP-TA -52.5* plywood combination Attached film top) with Trufast #14 HD spaced, staggered center rows Min. 19/32-inch One or more Prelim. Elastobase, OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and W 93 layers, any Elastobase P (poly- 12-inch o.c. at two, equally APP-SA-H APP-TA -60.0* plywood combination Attached film top) #12 spaced, staggered center rows APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., One or more Elastobase, Plates; 2 screws per plate installed into the 12-inch o.c. at min. 4-inch lap and Exposure 1 OSB or layers, any Loose -laid Elastobase P (poly- 12-inch o.c. at two (2), equally APP-SA-H APP-TA -67.5 min. 19/32" APA combination film top) holes of the plate, parallel to the width -direction width-directionW-94 spaced, staggered center rows of the sheet* rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 19/32-inch One or more Prelim. Elastobase, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 12-inch o.c. at min. 4-inch lap and W 95 layers, any Elastobase P (poly- Dekfast #14 or Trufast 3" Metal Insulation Plate 12-inch o.c. at two, equally SBS-SA-H SBS-TA -52.5* plywood combination Attached film top) with Trufast #14 HD spaced, staggered center rows NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 22 of 94 NNEMO etc. TABLE 1F: DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER MEOW- SYS EM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Insulation Layer(s) System Deck (Note 1) (Note 13) Base Sheet Roof Cover (Note 15) MDP No. Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply (Psf) One or more Elastobase, 12-inch o.c. at min. 4-inch lap and W 96 Min. 19/32-inch layers, any Prelim. Elastobase P (poly- #12 OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at two, equally SBS-SA-H SBS-TA -60.0* plywood combination Attached film top) spaced, staggered center rows APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., One or more Elastobase, 12-inch o.c. at min. 4-inch lap and holes off the plate, parallel to the width -direction Exposure 1 OSB or layers, any Loose -laid Elastobase P (poly- Plates; screws per plate installed into the 12-inch o.c. at two (2), equally SBS-SA-H SBS-TA -67.5 width-directionW-97 min. 19/32" APA combination film top) of the sheet* spaced, staggered center rows rated plywood Note: For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance TABLE 1G: ••• •ECKS — NEW CONSTRUCTION OR • ••• • • SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System Base Sheet IRoof Cover (Note 15) MDP Deck (Note 1) No. Type Fasten (Note 11) Attach Base Ply Cap Ply (Psf) No BASE PLY: Min. 15/32-inch 9-inch o.c. at min. 2-inch lap and 18-inch o.c. SBS-AA, SBS TA, W 98 plywood Elastobase, Elastobase P Simplex MAXX Cap at two (2), equally spaced, staggered center None APP-TA -45.0* rows APA rated, 7/16 Elastobase, Elastobase P or 32 ga., 1-5/8-inch diameter tin caps with 12 ga. 6-inch o.c. at min. 3-inch lap and 6-inch o.c. SBS-AA, SBS-TA, W-99 CAT, 0.418 in., at four (4), equally spaced, staggered center None -45.0 Elastovent annular ring shank nails APP TA Exposure 1 OSB rows APA rated, 7/16 Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 12 ga. 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W-100 CAT, 0.418 in., top) annular ring shank nails at four (4), equally spaced, staggered center None SBS-SA, APP-SA -45.0 Exposure 1 OSB rows rows APA rated, 7/16 32 ga., 1-5/8-inch diameter tin caps with 12 ga. 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W-101 CAT, 0.418 in., Polyglass Base at four (4), equally spaced, staggered center None APP-TA -45.0 annular ring shank nails Exposure 1 OSB rows Min. 15/32-inch 9-inch o.c. at min. 2-inch lap and 12-inch o.c. SBS-AA, SBS-TA, W-102 plywood Elastobase, Elastobase P Simplex MAXX Cap at two (2), equally spaced, staggered center None APP-TA -52.5 rows Min. 15/32-inch Elastobase, Elastobase P or Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at min. 3-inch lap and 6-inch o.c. SBS-AA, SBS TA, W-103 diameter, 11 gauge x min. 1.25-inch long annular at four (4), equally spaced, staggered center None -52.5 plywood Elastovent grooved shank) rows APP-TA NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for FL3654-R27 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 23 of 94 NNEMO I etc. IG: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) ATTACHEDTABLE SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY : BONDED ROO System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) Min. 15/32-inch Elastobase, Elastobase P Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W-104 plywood (poly -film top) diameter, 11 gauge x min. 1.25-inch long annular at four (4), equally spaced, staggered center None SBS-SA, APP-SA -52.5 grooved shank) rows Min. 15/32-inch Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W-105 plywood Polyglass Base diameter, 11 gauge x min. 1.25-inch long annular at four (4), equally spaced, staggered center None APP-TA -52.5 grooved shank) rows APA rated, 7/16 CAT, 0.418 in., 8-inch o.c. at min. 3-inch lap and 8-inch o.c. W-106 Exposure 1 OSB or Elastobase (sanded top) Simplex MAXX Cap at three (3), equally spaced, staggered None SBS-AA, SBS-TA, -60.0 min. 15/32" APA center rows APP TA rated plywood APA rated, 7/16 CAT, 0.418 in., 8-inch o.c. at min. 3-inch lap and 8-inch o.c. W-107 Exposure 1 OSB or Elastobase (poly -film top) Simplex MAXX Cap at three (3), equally spaced, staggered None SBS-TA, APP-TA -60.0 min. 15/32" APA center rows rated plywood APA rated, 7/16 CAT, 0.418 in., 8-inch o.c. at min. 3-inch lap and 8-inch o.c. W-108 Exposure 1 OSB or Polyglass Base Simplex MAXX Cap at three (3), equally spaced, staggered None APP-TA -60.0 min. 15/32" APA center rows rated plywood APA rated, 7/16 CAT, 0.418 in., Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. W-109 Exposure 1 OSB or Elastobase (poly -film top) Note: MAXX Caps are to be primed with PG100 or at three (3), equally spaced, staggered None SBS-SA, APP-SA -60.0 min. 15/32" APA ASTM D41 primer center rows rated plywood Elastobase, Elastobase P, Elastovent, Polyglass G2 8-inch o.c. at min. 4-inch lap and 8-inch o.c. W-110 Min. 19/32-inch Base, CertainTeed 32 ga., 1-5/8-inch diameter tin caps with 11 ga. at three (3), equally spaced, staggered None SBS-AA, SBS-TA, 60.0 plywood Glasbase, Firestone MB annular ring shank nails APP TA Base, JM Perma-Ply 28 or center rows GAFGLAS #75 Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. W-111 plywood (poly film top) annular ring shank nails at three (3), equally spaced, staggered None SBS-SA, APP-SA -60.0 center rows NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 24 of 94 NNEMO I etc. IG: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) ATTACHEDTABLE SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY : BONDED ROO System Base Sheet Roof Cover (Note 15) MDP Deck (Note 1) No. Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) Min. 15/32-inch Polyglass G2 Base, 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. SBS-AA, SBS-TA, W-112 Elastobase, Elastobase P or at four (4), equally spaced, staggered center None -67.5 plywood annular ring shank nails APP TA Elastovent rows Min. 15/32-inch 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. W-113 plywood Polyglass Base annular ring shank nails at four (4), equally spaced, staggered center None APP-TA -67.5 rows Min. 15/32-inch Polyglass G2 Base, 10-inch o.c. at min. 4-inch lap and 10-inch SBS-AA, SBS-TA, W-114 Simplex MAXX Cap o.c. at three (3), equally spaced, staggered None -75.0 plywood Elastobase, Elastobase P APP TA center rows Min. 15/32-inch 10-inch o.c. at min. 4-inch lap and 10-inch W-115 plywood Polyglass Base Simplex MAXX Cap o.c. at three (3), equally spaced, staggered None APP-TA -75.0 center rows Min. 15/32-inch Polyglass Base, 9-inch o.c. at min. 4-inch lap and 9-inch o.c. SBS-AA, SBS TA, W-116 Simplex MAXX Cap at four (4), equally spaced, staggered center None -90.0 plywood Elastobase, Elastobase P , APP-TA rows Min. 15/32-inch 9-inch o.c. at min. 4-inch lap and 9-inch o.c. W-117 plywood Polyglass Base Simplex MAXX Cap at four (4), equally spaced, staggered center None APP-TA -90.0 rows Min. 15/32-inch 6-inch o.c. at min. 2-inch lap and 6-inch o.c. SBS-AA, SBS-TA, W-118 Elastobase, Elastobase P Simplex MAXX Cap at two (2), equally spaced, staggered center None -90.0 plywood APP-TA rows Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c. at min. 4-inch lap and 4-inch o.c. W-119 plywood (poly -film top) annular ring shank nails. at four (4), equally spaced, staggered center None SBS-SA, APP-SA -97.5 rows Min. 15/32-inch 6-inch o.c. at min. 2-inch lap and 6-inch o.c. SBS-AA, SBS-TA, W-120 Elastobase, Elastobase P Simplex MAXX Cap at three (3), equally spaced, staggered None -105.0 plywood APP TA center rows Min. 19/32-inch Elastobase, Elastobase P or 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c. at min. 4-inch lap and 6-inch o.c., SBS-AA, SBS-TA, W-121 at four (4)equally spaced, staggered center None _112.5 plywood Elastovent annular ring shank nails APP-TA rows Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W 122 annular ring shank nails. Note: Tin caps are to be at four (4), equally spaced, staggered center None SBS-SA, APP-SA -112.5 plywood (poly -film top) primed with PG100 orASTM D41 primer. rows ASPHALT -APPLIED OR TORCH -APPLIED BASE PLY: NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 25 of 94 NNEMO I etc. TABLE IG: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEIVITYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE BONDED ROO System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) Min. 15/32-inch 9-inch o.c. at min. 2-inch lap and 18-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W-123 plywood Elastobase, Elastobase P Simplex MAXX Cap at two (2), equally spaced, staggered center TA APP TA SBS-AA, SBS-TA, -45.0* rows APP-TA APA rated, 7/16 Elastobase, Elastobase P or 32 ga., 1-5/8-inch diameter tin caps with 12 ga. 6-inch o.c. at min. 3-inch lap and 6-inch o.c. BP -AA SBS-AA, SBS- SBS-SA, APP-SA, W-124 CAT, 0.418 in., Elastovent annular ring shank nails at four (4), equally spaced, staggered center TA, APP-TA SBS-AA, SBS-TA, -45.0 Exposure 1 OSB rows APP-TA APA rated, 7/16 32 ga., 1-5/8-inch diameter tin caps with 12 ga. 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W-125 CAT, 0.418 in., Polyglass Base annular ring shank nails at four (4), equally spaced, staggered center APP-TA APP-TA -45.0 Exposure 1 OSB rows Min. 15/32-inch 9-inch o.c. at min. 2-inch lap and 12-inch o.c. BP -AA SBS-AA, SBS- SBS-SA, APP-SA, W-126 plywood Elastobase, Elastobase P Simplex MAXX Cap at two (2), equally spaced, staggered center TA, APP-TA SBS-AA, SBS-TA, -52.5 rows APP-TA Min. 15/32-inch Elastobase, Elastobase P or Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at min. 3-inch lap and 6-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W 127 plywood Elastovent diameter, 11 gauge x min. 1.25-inch long annular at four (4), equally spaced, staggered center TA, APP-TA SBS-AA, SBS-TA, -52.5 grooved shank) rows APP-TA Min. 15/32-inch Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W 128 plywood Polyglass Base Yg diameter, 11 gauge x min. 1.25-inch long annular 9 9 g at four (4), equally spaced, staggered center () q Y p gg APP-TA APP-TA -52.5 grooved shank) rows APA rated, 7/16 CAT, 0.418 in., 8-inch o.c. at min. 3-inch lap and 8-inch o.c. BP -AA, SBS-AA, SBS- SBS-AA, SBS-TA, W-129 Exposure 1 OSB or Elastobase (sanded top) Simplex MAXX Cap at three (3), equally spaced, staggered -60.0 min. 15/32" APA center rows TA, APP-TA APP-TA rated plywood APA rated, 7/16 CAT, 0.418 in., 8-inch o.c. at min. 3-inch lap and 8-inch o.c. W-130 Exposure 1 OSB or Elastobase (poly -film top) Simplex MAXX Cap at three (3), equally spaced, staggered SBS-TA SBS-TA, APP-TA -60.0 min. 15/32" APA center rows rated plywood APA rated, 7/16 CAT, 0.418 in., 8-inch o.c. at min. 3-inch lap and 8-inch o.c. W-131 Exposure 1 OSB or Polyglass Base Simplex MAXX Cap at three (3), equally spaced, staggered APP-TA APP-TA -60.0 min. 15/32" APA center rows rated plywood a Elastobase, Elastobase P, Min. 19/32-inch Elastovent, Polyglass Base, E astov7eed 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W 132 plywood Glasbase, annular ring shank nails at three (3), equally spaced, staggered TA, APP-TA SBS-AA, SBS-TA, 60.0 Firestone MB Base,1M Perma- center rows APP-TA Ply 28 or GAFGLAS #75 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 26 of 94 NNEMO I etc. TABLE IG: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE BONDED ROO System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) Min. 15/32-inch Polyglass G2 Base, 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W-133 plywood Elastobase, Elastobase P or annular ring shank nails at four (4), equally spaced, staggered center TA APP TA SBS-AA, SBS-TA, -67.5 Elastovent rows APP-TA Min. 15/32-inch 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. W-134 plywood Polyglass Base annular ring shank nails at four (4), equally spaced, staggered center APP-TA APP-TA -67.5 rows Min. 15/32-inch Polyglass Base, 10-inch o.c. at min. 4-inch lap and 10-inch BP -AA, SBS-AA, SBS SBS-SA, APP-SA, W-135 plywood Elastobase, Elastobase P , Simplex MAXX Cap o.c. at three (3), equally spaced, staggered TA, APP TA SBS-AA, SBS-TA, -75.0 center rows APP-TA Min. 15/32-inch 10-inch o.c. at min. 4-inch lap and 10-inch W-136 plywood Polyglass Base Simplex MAXX Cap o.c. at three (3), equally spaced, staggered APP-TA APP-TA -75.0 center rows Min. 15/32-inch Polyglass Base, 9-inch o.c. at min. 4-inch lap and 9-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W-137 plywood Elastobase, Elastobase P , Simplex MAXX Cap at four (4), equally spaced, staggered center TA, APP TA SBS-AA, SBS-TA, -90.0 rows APP-TA Min. 15/32-inch 9-inch o.c. at min. 4-inch lap and 9-inch o.c. W-138 plywood Polyglass Base Simplex MAXX Cap at four (4), equally spaced, staggered center APP-TA APP-TA -90.0 rows Min. 15/32-inch 6-inch o.c. at min. 2-inch lap and 6-inch o.c. BP -AA SBS-AA, SBS- SBS-SA, APP-SA, W-139 plywood Elastobase, Elastobase P Simplex MAXX Cap at two (2), equally spaced, staggered center TA, APP-TA SBS-AA, SBS-TA, -90.0 rows APP-TA Min. 15/32-inch 6-inch o.c. at min. 2-inch lap and 6-inch o.c. BP -AA SBS-AA, SBS- SBS-SA, APP-SA, W-140 plywood Elastobase, Elastobase P Simplex MAXX Cap at three (3), equally spaced, staggered TA, APP-TA SBS-AA, SBS-TA, -105.0 center rows APP-TA Min. 19/32-inch Elastobase, Elastobase P or 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c. at min. 4-inch lap and 6-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W-141 plywood Elastovent annular ring shank nails at four (3), equally spaced, staggered center TA, APP-TA SBS-AA, SBS-TA, -112.5 rows APP-TA SELF -ADHERING BASE PLY: APA rated, 7/16 Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 12 ga. 6-inch o.c. at min. 3-inch lap and 6-inch o.c. SBS-SA, APP-SA, W-142 CAT, 0.418 in., (poly -film top) annular ring shank nails at four (4), equally spaced, staggered center SBS-SA SBS-TA, APP-TA -45.0 Exposure 1 OSB rows Min. 15/32-inch Elastobase, Elastobase P Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at min. 3-inch lap and 6-inch o.c. SBS-SA, APP-SA, W-143 plywood (poly film top) diameter, 11 gauge x min. 1.25-inch long annular at four (4), equally spaced, staggered center SBS-SA SBS TA, APP-TA -52.5 grooved shank) rows NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 27 of 94 NNEMO I etc. IG: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) ATTACHEDTABLE SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY : BONDED ROO System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) APA rated, 7/16 CAT, 0.418 in., Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. W-144 Exposure 1 OSB or Elastobase (poly -film top) Note: MAXX Caps are to be primed with PG100 or at three (3), equally spaced, staggered SBS-SA SBS-SA, APP-SA, -60.0 min. 15/32" APA ASTM D41 primer center rows SBS-TA, APP-TA rated plywood Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. SBS-SA, APP-SA, W-145 plywood (poly -film top) annular ring shank nails at three (3), equally spaced, staggered SBS-SA SBS-TA, APP-TA -60.0 center rows Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c. at min. 4-inch lap and 4-inch o.c. SBS-SA, APP-SA, W-146 plywood (poly -film top) annular ring shank nails. at four (4), equally spaced, staggered center SBS-SA SBS-TA, APP-TA 97.5 rows Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c. at min. 4-inch lap and 6-inch o.c. Elastoflex SA V Plus, SBS-SA, APP-SA, W 147 plywood (poly -film top) annular ring shank nails. Note: Tin caps are to be at four (4), equally spaced, staggered center Elastoflex SA V Plus SBS-TA, APP-TA -112.5 primed with PG100 or ASTM D41 primer. rows FIR HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 15/32-inch Polyglass Base, Elastobase, Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W-148 plywood Elastobase P of film (p Y- diameter, 11 gauge x min. 1.25-inch long annular 9 9 g at four (4), equally spaced, staggered center () q Y p gg APP-SA-H APP-TA -52.5 top) grooved shank) rows Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. W-149 plywood (poly -film top) annular ring shank nails at three (3), equally spaced, staggered APP-SA-H APP-TA -60.0 center rows Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c. at min. 4-inch lap and 4-inch o.c. W-150 plywood (poly -film top) annular ring shank nails. at four (4), equally spaced, staggered center APP-SA-H APP-TA -97.5 rows Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W-151 plywood (poly -film top) annular ring shank nails. Note: Tin caps are to be at four (4), equally spaced, staggered center APP-SA-H APP-TA -112.5 primed with PG100 or ASTM D41 primer. rows HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: APA rated, 7/16 Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 12 ga. 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W-152 CAT, 0.418 in., (poly -film top) annular ring shank nails at four (4), equally spaced, staggered center SBS-SA-H SBS-TA -45.0 Exposure 1 OSB rows Min. 15/32-inch Elastobase, Elastobase P Original Simplex Cap Nails (1-inch metal head 6-inch o.c. at min. 3-inch lap and 6-inch o.c. W-153 plywood (poly film top) diameter, 11 gauge x min. 1.25-inch long annular at four (4), equally spaced, staggered center SBS-SA-H SBS-TA -52.5 grooved shank) rows NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 28 of 94 NNEMO I etc. TABLE IG: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASESHEET (NAILS), BONDED ROOF COVER MAM System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) APA rated, 7/16 CAT, 0.418 in., Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. W-154 Exposure 1 OSB or Elastobase (poly -film top) Note: MAXX Caps are to be primed with PG100 or at three (3), equally spaced, staggered SBS-SA-H SBS-TA -60.0 min. 15/32" APA ASTM D41 primer center rows rated plywood Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 8-inch o.c. at min. 4-inch lap and 8-inch o.c. W-155 plywood (poly -film top) annular ring shank nails at three (3), equally spaced, staggered SBS-SA-H SBS-TA -60.0 center rows Min. 19/32-inch Elastobase, Elastobase P 32 ga., 1-5/8-inch diameter tin caps with 11 ga. 4-inch o.c. at min. 4-inch lap and 4-inch o.c. W-156 plywood (poly -film top) annular ring shank nails. at four (4), equally spaced, staggered center SBS-SA-H SBS-TA -97.5 rows TABLE 1H: ••• •CONSTRUCTION,••• • • OR RECOVER SYSTEMTYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS& PLATES), BONDED ROOF COVER System F Base Sheet Roof Cover (Note 15) MDP Deck (Note 1) No. Type Fasten (Note 11) Attach Base Ply Cap (psf) No BASE PLY: Elastobase, Elastobase P, Elastovent, Polyglass G2 OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and 12-inch Min. 19/32-inch Base, CertainTeed #14, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with SBS-AA, SBS-TA, W-157 plywood Glasbase, Firestone MB Dekfast #14 or Trufast 3" Metal Insulation Plate o.c. at two (2), equally spaced, staggered None APP TA 52.5 Base, JM Perma-Ply 28 or with Trufast #14 HD center rows GAFGLAS #75 Min. 19/32-inch Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip . 12-inch o.4-inch lap and 12-inch at min. SBS-AA, SBS-TA, W-158 o.c. at two (2), equally spaced, staggered None -60.0 plywood or Elastovent #12 APP TA center rows APA rated, 19/32 CAT, 0.578 in., Trufast Versa Fasteners (min. %" penetration) & 12-inch o.c. at min. 4-inch lap and 12-inch Exposure 1 OSB or Elastobase, Elastobase P Plates; 2 screws per plate installed 180° into the o.c. at two (2), equally spaced, staggered None SBS-AA, SBS-TA, -67.5 W-159 min. 19/32" APA or Elastovent holes of the plate, parallel to the width -direction center rows APP-TA rated plywood of the sheet* Note: For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199 Ibf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.3654-1127 Revision 25: 09/30/2020 Appendix 1, Page 29 of 94 NNEMO I etc. TABLE 1H: ....REROOF (TEAR -OFF) OR RECOVER SYSTEMTYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS& PLATEs), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap (psf) APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., Elastobase, Elastobase P Plates; 2 screws per plate installed 180° into the 12-inch o.c. at min. 4-inch lap and 12-inch Exposure 1 OSB or (poly -film top) holes of the plate, parallel to the width -direction o.c. at two (2), equally spaced, staggered None SBS-SA, APP-SA -67.5 W-160 min. 19/32" APA of the sheet* center rows rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199 Ibff, Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., Plates; 2 screws per plate installed 180° into the 12-inch o.c. at min. 4-inch lap and 12-inch Exposure 1 OSB or Polyglass Base holes of the plate, parallel to the width -direction o.c. at two (2), equally spaced, staggered None APP-TA -67.5 W-161 min. 19/32" APA of the sheet* center rows rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch Polyglass G2 Base, Dekfast #14, OMG 3" Round Metal Plate with 10-inch o.c. at min. 4-inch lap and 10-inch SBS-AA, SBS-TA, W-162 plywood Elastobase, Elastobase P OMG HD, OMG Flat Bottom Plate (Accutrac) with o.c. at three (3), equally spaced, staggered None APP-TA -75.0 or Elastovent Roofgrip #14 or Trufast 3" Metal Insulation Plate center rows with Trufast #14 HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch Dekfast #14, OMG 3" Round Metal Plate with 10-inch o.c. at min. 4-inch lap and 10-inch W-163 plywood Polyglass Base OMG HD, OMG Flat Bottom Plate (Accutrac) with o.c. at three (3), equally spaced, staggered None APP-TA -75.0 Roofgrip #14 or Trufast 3" Metal Insulation Plate center rows with Trufast #14 HD. APA rated, 7/16 CAT, Trufast Versa Fasteners (min. %" penetration) & 9-inch o.c. at min. 2-inch lap and 12-inch o.c. 0.418 in., Exposure 1 Elastobase, Elastobase P Plates; 2 screws per plate installed 180° into the at two (2), equally spaced, staggered center None , SBS-AASBS-TA, -90.0 OSB or min. 15/32" or Elastovent holes of the plate, parallel to the width -direction APP-TA W-164 APA rated plywood of the sheet* rows Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 159 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance APA rated, 7/16 CAT, Trufast Versa Fasteners (min. %" penetration) & 9-inch at min. 2-inch lap and 12-inch o.c. 0.418 in., Exposure 1 Polyglass Base Plates; 2 screws per plate installed 180° into the at two (2), (2), equally spaced, staggered center None APP-TA -90.0 OSB or min. 15/32" holes of the plate, parallel to the width -direction W-165 APA rated plywood of the sheet* rows Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 159 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 30 of 94 NNEMO I etc. TABLE 1H: ....REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATEs), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap (psf) Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch Polyglass G2 Base, Dekfast #14, OMG 3" Round Metal Plate with 9-inch o.c. at min. 4-inch lap and 9-inch o.c. SBS-AA, SBS-TA, W-166 Elastobase, Elastobase P OMG HD, OMG Flat Bottom Plate (Accutrac) with at four (4), equally spaced, staggered center None -90.0 plywood or Elastovent Roofgrip #14 or Trufast 3" Metal Insulation Plate rows AP P TA with Trufast #14 HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch Dekfast #14, OMG 3" Round Metal Plate with 9-inch o.c. at min. 4-inch lap and 9-inch o.c. W-167 Polyglass Base Yg OMG HD, OMG Flat Bottom Plate Accutrac with ( ) at four (4), equally spaced, staggered center () q Y p gg None APP-TA -90.0 plywood Roofgrip #14 or Trufast 3" Metal Insulation Plate rows with Trufast #14 HD. Min. 15/32-inch Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3" 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W-168 at three (3), equally spaced, staggered center None SBS-AA -90.0 plywood or Elastovent Metal Insulation Plates rows Min. 15/32-inch Elastobase, Elastobase P OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and 6-inch o.c. SBS-AA, SBS-TA or W-169 Duty with OMG 3" Round Metal Plates or OMG at three (3), equally spaced, staggered center None -90.0 plywood or Elastovent Flat Bottom Metal Plates rows APP-TA Min. 15/32-inch OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W-170 Polyglass Base Duty with OMG 3" Round Metal Plates or OMG at three (3), equally spaced, staggered center None APP-TA -90.0 plywood Flat Bottom Metal Plates rows APA rated, 7/16 CAT, Trufast Versa Fasteners (min. %" penetration) & 0.418 in., Exposure 1 Elastobase, Elastobase P Plates; 2 screws per plate installed 180' into the 6-inch o.c. at min. 4-inch lap and 6-inch o.c. SBS-AA, SBS-TA, OSB or min. 15/32" or Elastovent holes of the plate, parallel to the width -direction at three (3), equally spaced, staggered center None APP-TA -105.0 W-171 APA rated plywood of the sheet* rows Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 103 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance APA rated, 7/16 CAT, Trufast Versa Fasteners (min.''/<" penetration) & 6-inch min. 4-inch lap and 6-inch o.c. 0.418 in., Exposure 1 Polyglass Base Plates; 2 screws per plate installed 180' into the at three (3),c. (, equally spaced, staggered center None APP-TA -105.0 OSB or min. 15/32" holes of the plate, parallel to the width -direction W-172 APA rated plywood of the sheet* rows Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 103 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance Min. 15/32-inch Elastobase, Elastobase P Trufast DP or Trufast #14 HD with Trufast 3" 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W-173 at five (5), equally spaced, staggered center None SBS-AA -120.0 plywood or Elastovent Metal Insulsul ation Plates rows Min. 15/32-inch Elastobase, Elastobase P OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and 6-inch o.c. SBS-AA, SBS-TA or W-174 Duty with OMG 3" Round Metal Plates or OMG at five (5), equally spaced, staggered center None -120.0 plywood or Elastovent Flat Bottom Metal Plates rows APP TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 31 of 94 NNEMO I etc. TABLE 1H: ....REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS& PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap (psf) Min. 15/32-inch OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W-175 Polyglass Base Duty with OMG 3" Round Metal Plates or OMG at five (5), equally spaced, staggered center None APP-TA -120.0 plywood Flat Bottom Metal Plates rows ASPHALT -APPLIED OR TORCH -APPLIED BASE PLY: Elastobase, Elastobase P, Elastovent, Polyglass G2 OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and 12-inch SBS-SA, APP-SA, Min. 19/32-inch Base, CertainTeed #14, Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with BP -AA, SBS-AA, SBS- W-176 plywood Glasbase, Firestone MB Dekfast #14 or Trufast 3" Metal Insulation Plate o.c. at two (2), equally spaced, staggered TA APP TA SBS-AA, SBS-TA, 52.5 Base, JM Perma-Ply 28 or with Trufast #14 HD center rows APP-TA GAFGLAS #75 Min. 19/32-inch Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and 12-inch BP -AA, SBS-AA, SBS SBS-SA, APP-SA, W 177 at two (2)equally spacedstaggered o.c. , , SBS-AA, SBS-TA, -60.0 plywood or Elastovent #12 TA, APP-TA center rows APP-TA APA rated, 19/32 CAT, 0.578 in., Trufast Versa Fasteners (min. %" penetration) & 12-inch o.c. at min. 4-inch lap and 12-inch SBS-SA, APP-SA, Elastobase, Elastobase P Plates; 2 screws per plate installed 180° into the BP -AA, SBS-AA, SBS- Exposure 1 OSB or or Elastovent holes of the plate, parallel to the width -direction o.c. at two (2), equally spaced, staggered TA, APP TA SBS AA, SBS TA, 67.5 W-178 min. 19/32" APA of the sheet* center rows APP TA rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199 Ibf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance APA rated, 19/32 CAT, 0.578 in., Trufast Versa Fasteners (min. %" penetration) & 12-inch o.c. at min. 4-inch lap and 12-inch Exposure 1 OSB or Polyglass Base Plates; 2 screws per plate installed 180° into the o.c. at two (2), equally spaced, staggered APP-TA APP-TA -67.5 W-179 min. 19/32" APA holes of the plate, parallel to the width -direction center rows rated plywood of the sheet* Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 1991bf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch Polyglass G2 Base, Dekfast #14, OMG 3" Round Metal Plate with 10-inch o.c. at min. 4-inch lap and 10-inch BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W-180 Elastobase, Elastobase P OMG HD, OMG Flat Bottom Plate (Accutrac) with o.c. at three (3), equally spaced, staggered SBS-AA, SBS-TA, -75.0 plywood or Elastovent Roofgrip #14 or Trufast 3" Metal Insulation Plate center rows TA, APP TA APP-TA with Trufast #14 HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch Dekfast #14, OMG 3" Round Metal Plate with 10-inch o.c. at min. 4-inch lap and 10-inch W-181 Polyglass Base OMG HD, OMG Flat Bottom Plate (Accutrac) with o.c. at three (3), equally spaced, staggered APP-TA APP-TA -75.0 plywood Roofgrip #14 or Trufast 3" Metal Insulation Plate center rows with Trufast #14 HD. NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 32 of 94 NNEMO I etc. TABLE 1H: ....REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS& PLATEs), BONDED ROOF COVER M&MM System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap (psf) APA rated, 7/16 CAT, Trufast Versa Fasteners (min. %" penetration) & 9-inch o.c. at min. 2-inch lap and 12-inch o.c. SBS-SA, APP-SA, 0.418 in., Exposure 1 Elastobase, Elastobase P Plates; 2 screws per plate installed 180° into the BP -AA, SBS-AA, SBS- OSB or min. 15/32" or Elastovent holes of the plate, parallel to the width -direction attwo(2), equally spaced, staggered center TA APP TA SBS-AA, SBS TA, 90.0 W-182 APA rated plywood of the sheet* TA Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 159lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance APA rated, 7/16 CAT, Trufast Versa Fasteners (min. %" penetration) & 9-inch o.c. at min. 2-inch lap and 12-inch o.c. 0.418 in., Exposure 1 Plates; 2 screws per plate installed 180° into the OSB or min. 15/32" Polyglass Base holes of the plate, parallel to the width -direction at two (2), equally spaced, staggered center APP-TA APP-TA -90.0 W-183 APA rated plywood of the sheet* rows Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 159 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch Polyglass G2 Base, Dekfast #14, OMG 3" Round Metal Plate with 9-inch o.c. at min. 4-inch lap and 9-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W-184 Elastobase, Elastobase P OMG HD, OMG Flat Bottom Plate (Accutrac) with at four (4), equally spaced, staggered center SBS-AA, SBS-TA, -90.0 plywood or Elastovent Roofgrip #14 or Trufast 3" Metal Insulation Plate rows TA, APP TA APP-TA with Trufast #14 HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Min. 15/32-inch Dekfast #14, OMG 3" Round Metal Plate with 9-inch o.c. at min. 4-inch lap and 9-inch o.c. W-185 Polyglass Base OMG HD, OMG Flat Bottom Plate (Accutrac) with at four (4), equally spaced, staggered center APP-TA APP-TA -90.0 plywood Roofgrip #14 or Trufast 3" Metal Insulation Plate rows with Trufast #14 HD. Min. 15/32-inch Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3" 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W-186 at three (3), equally spaced, staggered center BP -AA or SBS-AA SBS-AA -90.0 plywood or Elastovent Metal Insulation Plates rows Min. 15/32-inch Elastobase, Elastobase P OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and 6-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W 187 Duty (min. 1-5/8-inch long) with OMG 3" Round at three (3), equally spaced, staggered center SBS-AA, SBS-TA, -90.0 plywood or Elastovent Metal Plates or OMG Flat Bottom Metal Plates rows TA, APP TA APP-TA Min. 15/32-inch OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W 188 Polyglass Base Duty with OMG 3" Round Metal Plates or OMG at three (3), equally spaced, staggered center APP-TA APP-TA -90.0 plywood Flat Bottom Metal Plates rows APA rated, 7/16 CAT, Trufast Versa Fasteners (min. %" penetration) & 6-inch o.c. at min. 4-inch lap and 6-inch o.c. SBS-SA, APP-SA, 0.418 in., Exposure 1 Elastobase, Elastobase P Plates; 2 screws per plate installed 180° into the atthree (3), equally spaced, staggered center BP -AA, SBS-AA, SBS- SBS-AA, SBS-TA, -105.0 OSB or min. 15/32" or Elastovent holes of the plate, parallel to the width -direction TA, APP-TA W-189 APA rated plywood of the sheet* rows APP-TA Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 103 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 33 of 94 NNEMO I etc. TABLE 1H: ....REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS& PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap (psf) APA rated, 7/16 CAT, Trufast Versa Fasteners (min. %" penetration) & 6-inch min. 4-inch lap and 6-inch o.c. 0.418 in., Exposure 1 Polyglass Base Plates; 2 screws per plate installed 180° into the at threee (3), equally spaced, staggered center (, APP-TA APP-TA 105.0 OSB or min. 15/32" holes of the plate, parallel to the width -direction W-190 APA rated plywood of the sheet* rows Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 103 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance Min. 15/32-inch Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3" 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W-191 plywood or Elastovent Metal Insulation Plates at five (5), equally spaced, staggered center BP -AA or SBS-AA SBS-AA -120.0 rows Min. 15/32-inch Elastobase, Elastobase P OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and 6-inch o.c. BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, W-192 plywood or Elastovent Duty with OMG 3" Round Metal Plates or OMG at five (5), equally spaced, staggered center TA, APP TA SBS-AA, SBS-TA, -120.0 Flat Bottom Metal Plates rows APP-TA Min. 15/32-inch OMG #12 Standard Roofgrip or OMG #14 Heavy 6-inch o.c. at min. 4-inch lap and 6-inch o.c. W-193 Polyglass Base Duty with OMG 3" Round Metal Plates or OMG at five (5), equally spaced, staggered center APP-TA APP-TA -120.0 plywood Flat Bottom Metal Plates rows APA rated, 19/32 CAT, 0.578 in., Elastobase (sanded top) Trufast Versa Fasteners (min. %" penetration) & 9-inch o.c. at min. 4-inch lap and 9-inch o.c. BP -AA, SBS-AA, SBS- SBS-AA, SBS-TA, Exposure 1 OSB or or Elastovent Plates; 1 screws per plate in center hole* at four (4), equally spaced center rows TA, APP-TA APP-TA -127.5 W-194 min. 19/32" APA rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 141 Ibf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance APA rated, 19/32 CAT, 0.578 in., Trufast Versa Fasteners (min. %" penetration) & 9-inch o.c. at min. 4-inch lap and 9-inch o.c. Exposure 1 OSB or Elastobase (poly -film top) Plates; 1 screws per plate in center hole* at four (4), equally spaced center rows SBS-TA SBS-TA, APP-TA -127.5 W-195 min. 19/32" APA rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 141 Ibf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance APA rated, 19/32 CAT, 0.578 in., Trufast Versa Fasteners (min. %" penetration) & 9-inch o.c. at min. 4-inch lap and 9-inch o.c. Exposure 1 OSB or Polyglass Base Plates; 1 screws per plate in center hole* at four (4), equally spaced center rows APP-TA APP-TA -127.5 W-196 min. 19/32" APA rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 141 Ibf. Additional Versa -Fast Fasteners within each Versa -Fast Plate maybe utilized to produce minimum withdrawal resistance SELF -ADHERING BASE PLY: NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 34 of 94 NNEMO I etc. TABLE 1H: ....REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS& PLATES), BONDED ROOF COVER M&MM System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap (psf) Min. 19/32-inch Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 12-inch o.c. at min. 4-inch lap and 12-inch SBS-SA, APP-SA, W 197 plywood (poly -film top) Dekfast #14 or Trufast 3" Metal Insulation Plate o.c. at two (2), equally spaced, staggered SBS-SA SBS TA, APP-TA -52.5* with Trufast #14 HD center rows Min. 19/32-inch Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and 12-inch SBS-SA, APP-SA, W 198 plywood (poly -film top) #12 o.c. at two (2), equally spaced, staggered SBS-SA SBS-TA, APP-TA _60.0* center rows APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., Elastobase, Elastobase P Plates; 2 screws per plate installed 180° into the 12-inch o.c. at min. 4-inch lap and 12-inch SBS-SA, APP-SA, Exposure 1 OSB or (poly -film top) holes of the plate, parallel to the width -direction o.c. at two (2), equally spaced, staggered SBS-SA SBS-TA, APP-TA -67.5 W_199 min. 19/32" APA of the sheet* center rows rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., Plates; 1 screws per plate in center hole* 9-inch o.c. at min. 4-inch lap and 9-inch o.c. SBS-SA, APP-SA, Exposure 1 OSB or Elastobase (poly -film top) Note: Versa -Fast Plates shall be primed with at four (4), equally spaced center rows SBS-SA SBS-TA, APP-TA -127.5 W-200 min. 19/32" APA rated plywood PG100 orASTM D41 primer. Note: For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 141 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 19/32-inch Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 12-inch o.c. at min. 4-inch lap and 12-inch W-201 plywood (poly -film top) Dekfast #14 or Trufast 3" Metal Insulation Plate o.c. at two (2), equally spaced, staggered APP-SA-H APP-TA -52.5* with Trufast #14 HD center rows Min. 19/32-inch Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and 12-inch W 202 plywood (poly -film top) #12 o.c. at two (2), equally spaced, staggered APP-SA-H APP-TA -60.0* center rows APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., Elastobase, Elastobase P Plates; screws per plate installed into the 12-inch o.c. at min. 4-inch lap and 12-inch Exposure 1 OSB or (poly -film top) holes off the plate, parallel to the width -direction o.c. at two (2), equally spaced, staggered APP-SA-H APP-TA -67.5 W-203 min. 19/32" APA of the sheet* center rows rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 35 of 94 NNEMO I etc. TABLE 1H: ....REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS& PLATEs), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten (Note 11) Attach Base Ply Cap (psf) Min. 19/32-inch Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with 12-inch o.c. at min. 4-inch lap and 12-inch W-204 Dekfast #14 or Trufast 3" Metal Insulation Plate o.c. at two (2), equally spaced, staggered SBS-SA-H SBS-TA -52.5* plywood (poly -film top) with Trufast #14 HD center rows Min. 19/32-inch Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. at min. 4-inch lap and 12-inch W-205 plywood (poly -film top) #12 o.c. at two (2), equally spaced, staggered SBS-SA-H SBS-TA -60.0* center rows APA rated, 19/32 CAT, 0.578 in., Trufast Versa Fasteners (min. %" penetration) & 12-inch o.c. at min. 4-inch lap and 12-inch Exposure 1 OSB or Elastobase, Elastobase P Plates; 2 screws per plate installed 180' into the o.c. at two (2), equally spaced, staggered SBS-SA-H SBS-TA -67.5 W-206 min. 19/32" APA (poly -film top) holes of the plate, parallel to the width -direction center rows of the sheet* rated plywood Note: *For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 199 lbf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance APA rated, 19/32 Trufast Versa Fasteners (min. %" penetration) & CAT, 0.578 in., Plates; 1 screws per plate in center hole* 9-inch o.c. at min. 4-inch lap and 9-inch o.c. Exposure 1 OSB or Elastobase (poly -film top) Note: Versa -Fast Plates shall be primed with at four (4), equally spaced center rows SBS-SA-H SBS-TA -127.5 W-207 min. 19/32" APA rated plywood PG100 or ASTM D41 primer. Note: For re -roof or recover construction, field withdrawal resistance testing (Note 11) shall yield minimum 141 Ibf. Additional Versa -Fast Fasteners within each Versa -Fast Plate may be utilized to produce minimum withdrawal resistance NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 36 of 94 NNEMO I etc. TABLE 11: WOOD DECKS — NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER System Roof Cover (Note 15) Deck (Note 1) Primer MDP (psf) No. Joint Treatment Base Ply Ply Cap Ply SELF -ADHERING BASE PLY: APA rated, Elastoflex SA V Plus 7/16 CAT, OSB joints are covered with 4-inch wide strips of Elastoflex SA V, rolled into (Optional) SBS-SA, SBS- SBS-SA, APP-SA, W 208 None or Elastoflex SA V 52.5 0.418 in., place to create continuous bond. Plus FR TA, APP-TA SBS-TA, APP-TA Exposure 1 OSB Min. 15/32- (Optional) SBS-SA, SBS- SBS-SA, APP-SA, W 209 inch plywood None None SBS-SA TA, APP-TA SBS-TA, APP-TA -90.0 Min. 15/32- (Optional) SBS-SA, SBS- SBS-SA, APP-SA, W-210 inch plywood PG100 None SBS-SA TA, APP-TA SBS-TA, APP-TA -97.5 Min. 15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled Elastoflex SA V or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, W-211 inch plywood (Optional) PG100 into place to create continuous bond. Elastoflex SA V FR TA, APP-TA SBS-TA, APP-TA 97.5 Min. 15/32- POLYBRITE 745 (Optional) SBS-SA, SBS- SBS-SA, APP-SA, W 212 inch plywood or WB3000 None SBS-SA TA, APP-TA SBS-TA, APP-TA -105.0 Min. 15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled Elastoflex SA V Plus (Optional) SBS-SA, SBS- SBS-SA, APP-SA, W-213 inch plywood (Optional) PG100 into place to create continuous bond. or Elastoflex SA V TA, APP-TA SBS-TA, APP-TA -135.0 Plus FR HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 15/32- W-214 (Optional) PG100 None APP-SA-H (Optional) APP-TA APP-TA -90.0 inch plywood Min. 15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled W-215 (Optional) PG100 APP-SA-H (Optional) APP-TA APP-TA -135.0 inch plywood into place to create continuous bond. HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 15/32- W-216 None None SBS-SA-H (Optional) SBS-TA SBS-TA -90.0 inch plywood Min. 15/32- W 217 inch plywood PG100 None SBS-SA-H (Optional) SBS-TA SBS-TA -97.5 Min. 15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled W 218 (Optional) PG100 SBS-SA-H (Optional) SBS-TA SBS-TA -97.5 inch plywood into place to create continuous bond. W 219 Min. 15/32- POLYBRITE 745 None SBS-SA-H (Optional) SBS-TA SBS-TA 105.0 inch plywood or WB3000 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 37 of 94 NNEMO I etc. TABLE 2A: STEEL ORREROOF (TEAR -OFF) OR RECOVE SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVEN Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) Deck System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Base Ply Ply MDP Cap Ply (psf) (Notes 6,7,8) ASPHALT- OR TORCH -APPLIED BASE PLY: Min. 22 ga., type Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.75-inch Fesco Board (Optional if (Optional if using B, Grade 33 steel Min. 1.5-inch Polytherm, 7/8) with Dekfast #14, Trufast 3" 1 per (homogeneous) or min. 0.5-inch using AA Base) BP -AA, SBS-AA, S-1. or min. 2,500 psi ACFoam II, ENRGY 3, H- Metal Insulation Plate with Trufast 2.0 ft2 Structodek High Density Hot asphalt - Ply) BP -AA, SBS-AA, SBS-TA or SBS-TA, -45.0* structural Shield or Polytherm #14 HD or OMG 3-inch Galy Plate Fiberboard Roof Insulation SBS-AA APP-TA APP TA concrete with OMD HD Min. 22 ga., type Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.75-inch Fesco Board (Optional if (Optional if using B, Grade 33 steel Min. 2-inch Polytherm, 7/8) with Dekfast #14, Trufast 3" 1 per (homogeneous) or min. 0.5-inch using AA Base) BP -AA, SBS-AA, S-2. or min. 2,500 psi ACFoam II, ENRGY 3, H- Metal Insulation Plate with Trufast 4.0 ft2 Structodek High Density Hot asphalt - Ply) BP -AA, AA, SBS-AA, SBS-TA or SBS-TA, -45.0* structural Shield or Polytherm #14 HD or OMG 3-inch Galv Plate Fiberboard Roof Insulation SBS-AA APP-TA APP-TA concrete with OMD HD Min. 22 ga., type Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.75-inch Fesco Board (Optional if (Optional if using B, Grade 33 steel Min. 1.5-inch ENRGY 3, 7/8) with Dekfast #14 or Trufast 3" 1 per (homogeneous) or min. 0.5-inch using AA AA Base) BP -AA, SBS-AA, S-3. or min. 2,500 psi H-Shield or Polytherm Metal Insulation Plate with Trufast 1.3 ftZ Structodek High Density Hot asphalt Ply) BP -AA, SBS-AA, SBS-TA or SBS-TA, -90.0 structural #14 HD Fiberboard Roof Insulation SBS-AA APP-TA APP-TA concrete Min. 22 ga., type BP -AA, SBS- B, Grade 33 steel Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.75-inch Fesco Board AA (Top SBS-SA, S-4. or min. psi Min. 1.5-inch ENRGY 3, 7/8) with Dekfast #14 or Trufast 3" 1 per (homogeneous) or min. 0.5-inch Hot asphalt surface SBS-SA, SBS-TA or APP-SA, 90.0 structuraall H-Shield or Polytherm Metal Insulation Plate with Trufast 1.3 ftZ Structodek High Density primed APP-TA SBS-TA or #14 HD Fiberboard Roof Insulation with PG100 APP-TA concrete primer) Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Min. 0.25-inch DensDeck Prime, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per DEXcell FA Glass Mat Roof SBS-AA, (Optional) SBS-AA, SBS-AA, S-5. or min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ftZ Board or SECUROCK Gypsum- D-IS SBS-TA, SBS-TA, APP-TA SBS-TA, 30.0* structuraall H-Shield or Multi -Max Metal Insulation Plate with Trufast Fiber Roof Board APP-TA APP-TA concrete FA3 #14 HD Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Min. 0.25-inch DensDeck Prime, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per DEXcell FA Glass Mat Roof SBS-AA, (Optional) SBS-AA, SBS-AA, S-6. or min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ftZ Board or SECUROCK Gypsum- D-IS SBS-TA, SBS-TA, APP-TA SBS-TA, 45.0 structuraall H-Shield or Multi -Max Metal Insulation Plate with Trufast Fiber Roof Board APP-TA APP-TA concrete FA3 #14 HD NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 38 of 94 NNEMO I etc. TABLE 2A: STEEL OR •.. SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVEN Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) Min. 0.25-inch DensDeck Prime, Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- DEXcell FA Glass Mat Roof Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Board, SECUROCK Gypsum- B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Fiber Roof Board or SECUROCK M-OSFA or SBS-AA, (Optional) SBS-AA, SBS-AA, S-7. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ft2 Glass -Mat Roof Board, min. M-PG1 SBS-TA, SBS-TA, APP-TA SBS-TA, 30.0* structural l H-Shield or Multi -Max Metal Insulation Plate with Trufast 7/16-inch DEXcell Cement Roof APP-TA APP-TA concrete FA3 #14 HD Board or min. 0.5-inch SECUROCK Cement Roof Board Min. 0.25-inch DensDeck Prime, Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- DEXcell FA Glass Mat Roof Min. 22 ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Board, SECUROCK Gypsum- B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Fiber Roof Board or SECUROCK M-OSFA or SBS-AA, (Optional) SBS-AA, SBS-AA, S-8. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ft2 Glass -Mat Roof Board, min. M-PG1 SBS-TA, SBS-TA, APP-TA SBS-TA, 45.0 structural l H-Shield or Multi -Max Metal Insulation Plate with Trufast 7/16-inch DEXcell Cement Roof APP-TA APP-TA concrete FA3 #14 HD Board or min. 0.5-inch SECUROCK Cement Roof Board Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Min. 0.25-inch DensDeck Prime, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per DEXcell FA Glass Matg Roof SBS-AA, (Optional) SBS-AA, SBS-AA, 5-9. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ft2 Board or SECUROCK Gypsum- OB500 SBS-TA, SBS-TA, APP-TA SBS-TA, 30.0* structural l H-Shield or Multi -Max Metal Insulation Plate with Trufast Fiber Roof Board APP-TA APP-TA concrete FA3 #14 HD Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Min. 0.25-inch DensDeck Prime, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per DEXcell FA Glass Mat Roof SBS-AA, (Optional) SBS-AA, SBS-AA, S 10. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ft2 Board or SECUROCK Gypsum- OB500 SBS-TA, SBS-TA, APP-TA SBS-TA, 45.0 structural l H-Shield or Multi -Max Metal Insulation Plate with Trufast Fiber Roof Board APP-TA APP TA concrete FA3 #14 HD Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Min. 0.25-inch DensDeck Prime 565-AA, (Optional) SBS-AA, SBS-AA, 5-11. or min. 2,500 psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ft2 or SECUROCK Gypsum -Fiber CR-20 SBS-TA, SBS-TA, APP-TA SBS-TA, -30.0* structural Roof Board APP-TA APP-TA H-Shield or Multi -Max Metal Insulation Plate with Trufast concrete FA3 #14 HD NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 39 of 94 NNEMO I etc. TABLE 2A: STEEL ORREROOF (TEAR -OFF) OR RECOVE SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVEN Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Min. 0.25-inch DensDeck Prime SBS-AA, (Optional) SBS-AA, SBS-AA, 5-12. or min. 2,500 psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" Z 1.6 ft or SECUROCK Gypsum -Fiber CR-20 SBS-TA, SBS-TA, APP-TA SBS-TA, -45.0 structural H-Shield or Multi -Max Metal Insulation Plate with Trufast Roof Board APP-TA APP TA concrete FA3 #14 HD SELF -ADHERING BASE PLY: Min. 22 ga., type Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.25-inch DensDeck Prime B, Grade 40 steel ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" or SECUROCK Gypsum -Fiber SBS-CA1, 5-13. or min. 2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Roof Board D-IS SBS-SA None SBS-CA2, -30.0* Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 2 4.0 ft structural H-Shield or Multi -Max Metal Insulation Plate with Trufast PRIMER: POLYBRITE 745 or APP-CA1 concrete FA3 #14 HD WB3000 Min. 22 ga., type Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.25-inch DensDeck Prime B, Grade 40 steel ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" or SECUROCK Gypsum -Fiber SBS-CA1, 5-14. or min. 2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Roof Board D-IS SBS-SA None SBS-CA2, -45.0 Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ftz structural H-Shield or Multi -Max Metal Insulation Plate with Trufast PRIMER: POLYBRITE 745 or APP-CA1 concrete FA3 #14 HD WB3000 Min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Gypsum -Fiber Roof Board or Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" SECUROCK Glass -Mat Roof B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Board, min. 7/16-inch DEXcell M-OSFA or SBS-CA1, 5-15. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ftZ Cement Roof Board or min. 0.5- M-PG1 SBS-SA None SBS-CA2, 30.0 * s structuraall H-Shield or Multi -Max Metal Insulation Plate with Trufast inch SECUROCK Cement Roof APP-CA1 concrete FA3 #14 HD Board PRIMER: POLYBRITE 745 or WB3000 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 40 of 94 NNEMO I etc. TABLE 2A: STEEL OR •.. SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVEN Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) Min. 0.25-inch DensDeck, DensDeck Prime, SECUROCK Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Gypsum -Fiber Roof Board or Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" SECUROCK Glass -Mat Roof B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Board, min. 7/16-inch DEXcell M-OSFA or SBS-CA1, S-16. or min. 2,500 psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ftz Cement Roof Board or min. 0.5- M-PG1 SBS-SA None SBS-CA2, -45.0 structural H-Shield or Multi -Max Metal Insulation Plate with Trufast inch SECUROCK Cement Roof APP-CA1 concrete FA3 #14 HD Board PRIMER: POLYBRITE 745 or WB3000 Min. 22 ga., type Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.25-inch DensDeck Prime B, Grade 40 steel ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" or SECUROCK Gypsum -Fiber SBS-CA1, S-17. or min. 2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Roof Board OB500 SBS-SA None SBS-CA2, -30.0* Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ft z structural H-Shield or Multi -Max Metal Insulation Plate with Trufast PRIMER: POLYBRITE 745 or APP-CA1 concrete FA3 #14 HD WB3000 Min. 22 ga., type Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.25-inch DensDeck Prime B, Grade 40 steel ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" or SECUROCK Gypsum -Fiber SBS-CA1, S-18. or min. 2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Roof Board OB500 SBS-SA None SBS-CA2, -45.0 Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ft z structural H-Shield or Multi -Max Metal Insulation Plate with Trufast PRIMER: POLYBRITE 745 or APP-CA1 concrete FA3 #14 HD WB3000 Min. 22 ga., type Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.25-inch DensDeck Prime B, Grade 40 steel ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" or SECUROCK Gypsum -Fiber SBS-CA1, S-19. or min. 2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Roof Board CR-20 SBS-SA None SBS-CA2, -30.0* Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" Z 4.0 ft structural H-Shield or Multi -Max Metal Insulation Plate with Trufast PRIMER: POLYBRITE 745 or APP-CA1 concrete FA3 #14 HD WB3000 Min. 22 ga., type Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. 0.25-inch DensDeck Prime B, Grade 40 steel ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" or SECUROCK Gypsum -Fiber 565-CA1, S-20. or min. 2,500 psi EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Roof Board CR-20 SBS-SA None SBS-CA2, -45.0 Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ft z structural H-Shield or Multi -Max Metal Insulation Plate with Trufast PRIMER: POLYBRITE 745 or APP-CA1 concrete FA3 #14 HD WB3000 COLD -APPLIED BASE PLY: NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 41 of 94 NNEMO I etc. TABLE 2A: STEEL OR •.. SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVEN Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Min. 0.25-inch DensDeck Prime, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per DEXcell FA Glass Mat Roof SBS-CA1, (Optional) SBS SBS-CA1, 5-21. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ft2 Board or SECUROCK Gypsum- D-IS SBS-CA2 CAI, SBS-CA2 SBS-CA2, 30.0* structural l H-Shield or Multi -Max Metal Insulation Plate with Trufast Fiber Roof Board APP-CA1 concrete FA3 #14 HD Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., type ACFoam ll, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Min. 0.25-inch DensDeck Prime, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per DEXcell FA Glass Mat Roof SBS-CA1, (Optional) SBS- SBS-CA1, 5-22. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ft2 Board or SECUROCK Gypsum- D-IS SBS-CA2 CAI, SBS-CA2 SBS-CA2, 45.0 structural l H-Shield or Multi -Max Metal Insulation Plate with Trufast Fiber Roof Board APP-CAI concrete FA3 #14 HD Min. 0.25-inch DensDeck, Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- DensDeck Prime, DEXcell FA Min. 22 ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Glass Mat Roof Board, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per SECUROCK Gypsum -Fiber Roof M-OSFA or SBS-CA1, (Optional) SBS- SBS-CAI, 5-23. or min. 2,500 psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ft2 Board or SECUROCK Glass -Mat M-PG1 SBS-CA2 CAI, SBS-CA2 SBS-CA2, -30.0* structural Roof Board, min. 7/16-inch APP-CA1 concrete H-Shield or Multi -Max Metal Insulation Plate with Trufast DEXcell Cement Roof Board or FA3 #14 HD min. 0.5-inch SECUROCK Cement Roof Board Min. 0.25-inch DensDeck, Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- DensDeck Prime, DEXcell FA Min. 22 ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Glass Mat Roof Board, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per SECUROCK Gypsum -Fiber Roof M-OSFA or SBS-CAI, (Optional) SBS- SBS-CAI, 5-24. or min. 2,500 psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ft2 Board or SECUROCK Glass -Mat M-PG1 SBS-CA2 CAI, SBS-CA2 SBS-CA2, -45.0 structural Roof Board, min. 7/16-inch APP-CA1 H-Shield or Multi -Max Metal Insulation Plate with Trufast concrete FA3 #14 HD DEXcell Cement Roof Board or min. 0.5-inch SECUROCK Cement Roof Board Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Min. 0.25-inch DensDeck Prime, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per DEXcell FA Glass Matg Roof SBS-CA1, (Optional) SBS- SBS-CAI, S 25. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ft2 Board or SECUROCK Gypsum- OB500 SBS-CA2 CAI, SBS-CA2 SBS-CA2, 30.0 * s structuraall H-Shield or Multi -Max Metal Insulation Plate with Trufast Fiber Roof Board APP-CAI concrete FA3 #14 HD NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 42 of 94 NNEMO I etc. TABLE 2A: STEEL OR •.. SYSTEIVITYPEB-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVEN Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Type Fasten (Note 11) Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" Min. 0.25-inch DensDeck Prime, B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per DEXcell FA Glass Matg Roof SBS-CA1, (Optional) SBS SBS-CA1, 5-26. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ft2 Board or SECUROCK Gypsum- OB500 SBS-CA2 CAI, SBS-CA2 SBS-CA2, 45.0 structural l H-Shield or Multi -Max Metal Insulation Plate with Trufast Fiber Roof Board APP-CA1 concrete FA3 #14 HD Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. 22 ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Min. 0.25-inch DensDeck Prime SBS-CA1, (Optional) SBS- SBS-CA1, 5-27. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 4.0 ft2 or CK Gypsum -Fiber CR-20 SBS-CA2 CAI, SBS-CA2 SBS-CA2, 30.0* s al structural H-Shield or Multi -Max Metal Insulation Plate with Trufast of BoarSECUR Roof Board APP-CAI concrete FA3 #14 HD Min. 2-inch Polytherm, Dekfast Hex (aka, Dekfast PLT-H-2- Min. ga., type ACFoam II, ENRGY 3, 7/8) with Dekfast #14, OMG 3" B, Grade 40 steel EnergyGuard Polyiso Galvalume Ribbons Plates with 1 per Min. 0.25-inch DensDeck Prime SBS-CA1, (Optional) SBS SBS-CAI, 5-28. r min. psi Insulation, Polytherm H, OMG #14 Roofgrip or Trufast 3" 1.6 ft2 or CK Gypsum -Fiber CR-20 SBS-CA2 CAI, SBS-CA2 SBS-CA2, 45.0 structural s al H-Shield or Multi -Max Metal Insulation Plate with Trufast of BoarSECUR Roof Board APP-CAI concrete FA3 #14 HD NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-1127 Revision 25: 09/30/2020 Appendix 1, Page 43 of 94 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEMTYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No Deck (Note 1) Layer (Note 13) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply (psf) ASPHALT- OR TORCH -APPLIED BASE PLY: Min. 22 ga., type B, OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate (Optional if (Optional if using Grade 33 steel or One or more layers, Min. 0.75-inch JM Fesco Board with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, 1 per using AA Ply) AA Base) BP -AA, SBS-AA, S 29. 2,500 any combination, (homogeneous) or min. 1.5-inch Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 2.0 ft2 BP SBS- SBS-AA, SBS-TA SBS-TA, -45.0* min. psi loose laid JM Fesco Board (laminated) DP (steel only) or Dekfast #14, Trufast 3" Metal Insulation -AA, or APP-TA structural concrete Plate with Trufast #12 DP (steel only) or Trufast #14 HD AA APP-TA Min. 22 ga., type B, Min. 0.5-inch Structodek High OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate (Optional if (Optional if using Grade 33 steel or One or more layers, Density Fiberboard Roof with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, 1 per using AA Ply) AA Base) BP -AA, SBS-AA, S 30. min. 2,500 psi any combination, Insulation or G-P FiberBase HD Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 40 ft2 . BP-AASBS- SBS-AASBS-TA or SBS-TA, 45.0* loose laid DP (steel only) or Dekfast #14, Trufast 3" Metal Insulation , , gpp_Tq structural concrete or HD Excel Plate with Trufast #12 DP (steel only) or Trufast #14 HD AA APP-TA Min. 22 ga., type B, OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate (Optional if (Optional if using Grade 33 steel or One or more layers, Min. 0.25-inch DensDeck Prime with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, 1 per using AA Ply) AA Base) BP -AA, SBS-AA, 45.0 * 5-31. 2,500 any combination, or SECUROCK Gypsum -Fiber Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 2 4.0 ft BP SBS- SBS-AA, SBS-TA SBS-TA, min. psi loose laid Roof Board DP steel only) or Dekfast #14, Trufast 3" Metal Insulation ( Y) -AA, or APP TA structural concrete Plate with Trufast #12 DP (steel only) or Trufast #14 HD AA APP-TA Min. 22 a., type B, g yp (Optional) One or ( p ) OMG AccuTrac Plate or OMG 3 in. Ribbed Galvalume Plate (Optional if (Optional if using Grade 33 steel or more layers, any with #12 Roofgrip (steel only) or OMG #14 Heavy Duty, 1 per using AA Ply) AA Base) BP -AA SBS-AA, S-32. min. 2,500 psi combination, loose Min. 2-inch H-Shield WF Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 4.0 ft2 BP -AA, SBS- SBS-AA, SBS-TA, or SBS-TA, -45.0* DP (steel only) or Dekfast #14, Trufast 3" Metal Insulation APP-TA structural concrete laid Plate with Trufast #12 DP (steel only) or Trufast #14 HD AA APP-TA Dekfast PLT-H-2-7/8 or PTL-R-3 plates with Dekfast DF- Min. 22 ga., type B, One or more layers, #12-PH3, DF-#14-PH3 or DF-#15-PH3 fasteners or OMG 3 Grade 40 steel; 6 ft any combination, Min. 0.25-inch SECUROCK in. Ribbed Galvalume Plate 3 in Galvalume Steel Plate, . 1 per SBS-TA or (Optional) SBS-TA SBS-TA or S-33. span; 5/8" puddle min. 1.5" thick, loose Gypsum -Fiber Roof Board (Flat) or AccuTrac Flat Bottom Plate with OMG #12 2 2.0 ft APP TA or APP-TA APP TA -52.5 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip fasteners or welds, 6" o.c. laid Trufast 3" Metal Insulation Plate with Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD fasteners Dekfast PLT-H-2-7/8 or PTL-R-3 plates with Dekfast DF- Min. 22 ga., type B, One or more layers, #12-PH3, DF-#14-PH3 or DF-#15-PH3 fasteners or OMG 3 Grade 40 steel; 6 ft any combination, in. Galvalume Steel Plate, 3 in. Ribbed Galvalume Plate 1 per SBS-TA or (Optional) SBS-TA SBS-TA or S-34. span; 5/8" puddle min. 1.5" thick, loose Min. 0.25-inch DensDeck Prime (Flat) or AccuTrac Flat Bottom Plate with OMG #12 2 2.0 ft APP TA or APP TA APP-TA -60.0 Roofgrip, #14 Roofgrip or OMG #15 Roofgrip fasteners or welds, 6" o.c. laid Trufast 3" Metal Insulation Plate with Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD fasteners Dekfast PLT-H-2-7/8 or PTL-R-3 plates with Dekfast DF- Min. 22 ga., type B, One or more layers, #12-PH3, DF-#14-PH3 or DF-#15-PH3 fasteners or OMG 3 Grade 40 steel; 6 ft any combination, Min. 0.25-inch DensDeck Prime in. Galvalume Steel Plate, 3 in. Ribbed Galvalume Plate 1 per SBS-TA or (Optional) SBS-TA SBS-TA or S-35. span; 5/8" puddle min. 1.5" thick, loose or SECUROCK Gypsum -Fiber (Flat) or AccuTrac Flat Bottom Plate with OMG #12 1.6 ft' APP-TA or APP-TA APP-TA -67.5 Roof Board Roofgrip, #14 Roofgrip or OMG #15 Roofgrip fasteners or welds, 6" o.c. laid Trufast 3" Metal Insulation Plate with Trufast #12 DP, Trufast #14 HD or Trufast #15 EHD fasteners NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 44 of 94 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEMTYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Layer (Note 13) (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply Min. 22 ga., type B, (Optional) One or (Optional if (Optional if using Grade 33 steel or more layers, any Min. 0.5-inch SECUROCK OMG 3-inch Galvalume Steel Plate with OMG #14 1 per using AA Ply) AA Base) BP -AA, SBS-AA, 5-36. min. 2,500 psi combination, loose Gypsum -Fiber Roof Board HD 1.8 ftZ BP -AA, SBS- SBS-AA, SBS-TA or SBS-TA, 75.0 structural concrete laid AA APP-TA APP-TA Min. 0.5-inch Structodek High Min. 22 ga., type B, One or more layers, Density Fiberboard Roof Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with (Optional if (Optional if using SBS-AA, 5-37. Grade 33 steel or any combination, Insulation or min. 0.25-inch Dekfast #12 (steel only) or #14 or Trufast 3" Metal 1 per using AA Ply) AA Base) BP -AA, SBS-TA, -82.5 min. 2,500 psi loose laid DensDeck, DensDeck Prime or Insulation Plate with Trufast DP (steel only) or HD 1.3 ftz BP -AA, SBS- SBS-AA, SBS-TA or APP TA structural concrete SECUROCK Gypsum -Fiber Roof AA APP-TA Board SELF -ADHERING BASE PLY: Min. 22 ga., type B, (Optional) One or Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 SBS-SA, Grade 33 steel or more layers, any Min. 1.5-inch Polytherm, DP (steel only) or Dekfast #14, OMG AccuTrac Flat Bottom 1 per (Optional) SBS-SA, APP-SA, 5-38. min. 2,500 psi combination, loose ACFoam II, H-Shield or Plate with #12 Roofgrip (steel only) or OMG #14 Heavy 2.7 ftZ SBS-SA SBS-TA, APP-TA SBS-TA, -30.0 Polytherm Duty, Trufast 3" Metal Insulation Plate with Trufast #12 structural concrete laid DP (steel only) or Trufast #14 HD APP-TA Min. 22 ga., type B, One or more layers, Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or SBS-SA, Grade 40 steel or any combination, Min. 0.25-inch DensDeck Prime Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast 1 per (Optional) SBS-SA, APP-SA, S-39. min. 2,500 psi min. 1-inch, loose optionally primed with PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 2 7 ftz SBS-SA SBS-TA, APP-TA SBS-TA, -37.5* POLYBRITE 745 or WB3000 OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast structural concrete laid #15 EHD Fasteners with Trufast 3" Metal Insulation Plate APP-TA Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Min. 22 ga., type B, One or more layers, Min. 0.25-inch SECUROCK Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast SBS-SA, 5-40. Grade 40 steel or any combination, Gypsum -Fiber Roof Board PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 1 per SBS-SA (Optional) SBS-SA, APP-SA, 37.5* min. 2,500 psi min. 1-inch, loose optionally primed with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom 2.7 ftZ SBS-TA, APP-TA SBS-TA, structural concrete laid POLYBRITE 745 or WB3000 Plate or Trufast #14HD or Trufast #15 EHD Fasteners with APP-TA Trufast 3" Metal Insulation Plate Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast Min. 22 ga., type B, One or more layers, PLT-H-2-7/8), isofast PLT-S-2-3/4X2-3/4 or Dekfast SBS-SA, 5-41. Grade 40 steel or any combination, Min. 0.25-inch DEXcell FA Glass Galvalume Steel 3" Round (aka, Dekfast PLT-R-3) or OMG 1 per SBS SA (Optional) SBS-SA, APP-SA, 37.5* min. 2,500 psi min. 1-inch, loose Mat Roof Board #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal 2.7 ftZ SBS-TA, APP-TA SBS-TA, structural concrete laid Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or APP-TA Trufast #15 EHD Fasteners with Trufast 3" Metal Insulation Plate Min. 22 ga., type B, (Optional) One or SBS-SA, Grade 33 steel or more layers, any Min. 1.5-inch H-Shield or OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel 1 per (Optional) SBS-SA, APP-SA, S 42. min. 2,500 psi combination, loose Polytherm only) or #14 Heavy Duty, Trufast 3" Metal Insulation 2.0 ftZ SBS SA SBS-TA, APP-TA SBS-TA, 45.0* Plate with TTrufast #12 DP (steel only) or Trufast #14 HD r structural concrete laid APP-TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.3654-1127 Revision 25: 09/30/2020 Appendix 1, Page 45 of 94 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEMTYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Layer (Note 13) (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply Min. 22 ga., type B, One or more layers, Min. 0.25-inch DensDeck Prime Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, SBS-CA1, 5-43. Grade 33 steel or any combination, or SECUROCK Gypsum -Fiber OMG 3" Galvalume Ribbed Plates with OMG #14 RoofGrip 1 per SBS-SA None SBS-CA 45.0 * min. 2,500 psi Roof Board optionally primed or Trufast 3" Metal Insulation Plates with Trufast #14 HD 2.0 ftZ structural concrete loose laid with POLYBRITE 745 or WB3000 Fasteners APP-CA1 Min. 22 ga., type B, Min. 0.25-inch DensDeck Prime h d#12 bb l Pate (non -ribbed) with OMG 3 in. GalvalumeSBS-SA, Grade 33 steel or One or more layers, or SECUROCK Gypsum -Fiber Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex 1 per (Optional) SBS-SA, APP-SA, S-44. min. 2,500 psi any combination, Roof Board optionally primed (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel 2.0 ftZ SBS-SA SBS-TA or APP-TA SBS-TA or -45.0* loose laid only) or Dekfast #14, Trufast 3" Metal Insulation Plate structural concrete with POLYBRITE 745 or WB3000 with Trufast #12 DP (steel only) or Trufast #14 HD qpp-TA Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Min. 22 ga., type B, One or more layers, Min. 0.25-inch SECUROCK Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Grade 40 steel or any combination, Gypsum -Fiber Roof Board Galvalume Steel 3" Round (aka, Dekfast PLT-R-3) or OMG 1 per S 45. min. 2,500 psi min. 1-inch, loose optionally primed with Roofgrip with 3 in. Round Metal Plate, OMG 3 2 0 ftZ SBS-SA None 565-SA 45.0 in. in. Ribbed Galvalumea Plate (Flat) or Accutrac Flat Bottom structural concrete laid POLYBRITE 745 or WB3000 Plate or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plate Min. 22 ga., type B, One or more layers, Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Grade 40 steel or any combination, Min. 0.25-inch DensDeck Prime Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 1 per S-46. min. 2,500 psi min. 1-inch, loose optionally primed with Roofgrip with OMG 3 in. Round Metal Plate or Accutrac 2 0 ftZ SBS-SA None 565-SA -45.0 POLYBRITE 745 or WB3000 Flat Bottom Plate or Trufast #14 HD Fasteners with structural concrete laid Trufast 3" Metal Insulation Plate Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Min. 22 ga., type B, One or more layers, Min. 0.25-inch SECUROCK Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast (Optional when SBS-SA, S 47. Grade 40 steel or any combination, Gypsum -Fiber Roof Board PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 1 per SBS SA using torch- APP-SA, 45.0 min. 2,500 psi min. 1-inch, loose optionally primed with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom 1.8 ftZ applied Cap Ply) SBS-TA or structural concrete laid POLYBRITE 745 or WB3000 Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with SBS-TA, APP-TA APP-TA Trufast 3" Metal Insulation Plate Min. 22 ga., type B, One or more layers, (Optional when SBS-SA, Grade 40 steel or any combination, Min. 0.25-inch DensDeck Prime OMG #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round 1 per using torch- APP-SA, 5-48. min. 2,500 psi min. 1-inch, loose optionally primed with Metal Plate or Trufast #14 HD or Trufast #15 EHD 1 8 ftZ 565-SA applied Cap Ply) SBS-TA or -45.0 POLYBRITE 745 or WB3000 Fasteners with Trufast 3" Metal Insulation Plate structural concrete laid SBS-TA, APP-TA APP-TA Min. 22 ga., type B, (Optional) One or Min. 1.5-inch H-Shield or SBS-SA, 5-49. Grade 33 steel or more layers, any Polythoptionally primed Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 1 per SBS SA (Optional) SBS-SA, APP-SA, 60.0 min. 2,500 psi combination, loose DP (steel only) or Dekfast #14 2.0 ftZ SBS-TA, APP-TA SBS-TA, structural concrete laid with POOLYLYBRITE 745 or WB3000 APP-TA Min. 22 ga., type B, Min. 0.25-inch DensDeck Prime OMG 3 in. Galvalume Plate (non -ribbed) with #12 Grade 40 steel or One or more layers, or SECUROCK Gypsum -Fiber Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex 1 per (Optional) SBS-TA SBS-TA or S-50. min. 2,500 psi any combination, Roof Board optionally primed (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel 1.6 ftz SBS-SA or APP-TA APP-TA -60.0 loose laid only) or Dekfast #14, Trufast 3" Metal Insulation Plate structural concrete with POLYBRITE 745 or W B3000 with Trufast #12 DP (steel only) or Trufast #14 HD NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 46 of 94 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEMTYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Layer (Note 13) (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Min. 22 ga., type B, (Optional) One or Insulation, ENRGY 3, ENRGY 3 Galvalume Steel 3" Round Insulation Plate (aka, Dekfast SBS-SA, Grade 33 steel or more layers, any CGF, H-Shield, H-Shield CG, ISO PLT-R-3) with Dekfast #12 (steel only) or Dekfast #14, 1 per (Optional) SBS-SA, APP-SA, S-51. min. 2,500 psi combination, loose 95+ GL, Multi -Max FA3, OMG 3 in. Galvalume Plate (non -ribbed) or OMG 1.3 ftZ SBS-SA SBS-TA, APP-TA SBS-TA, -67.5* AccuTrac Plate with #12 Roofgrip (steel only) or OMG #14 structural concrete laid Polytherm or Ultra -Max Heavy DutyorTrufast 3" Metal Insulation Plate with APP-TA optionally primed with Trufast #12 DP (steel only) or Trufast #14 HD POLYBRITE 745 or WB3000 Min. 22 ga., type B, Min. 0.25-inch DensDeck Prime OMG 3 in. Galvalume Plate (non -ribbed) with #12 Grade 40 steel or One or more layers, or SECUROCK Gypsum -Fiber Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex 1 per (Optional) SBS-TA SBS-TA or S-52. min. 2,500 psi any combination, Roof Board optionally primed (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel 1.3 ftz SBS-SA or APP-TA APP-TA 72.5 loose laid only) or Dekfast #14, Trufast 3" Metal Insulation Plate structural concrete with POLYBRITE 745 or WB3000 with Trufast #12 DP (steel only) or Trufast #14 HD Min. 22 ga., type B, (Optional) One or S-53. Grade 33 steel or more layers, any Min. 0.5-inch SECUROCK OMG 3-inch Galvalume Steel Plate with OMG #14 HD 1 per SBS-SA (Optional) SBS-TA SBS-TA -75.0 min. 2,500 psi combination, loose Gypsum -Fiber Roof Board 1.8 ft structural concrete laid Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Min. 22 ga., type B, One or more layers, Min. 0.25-inch SECUROCK Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast Grade 40 steel or any combination, Gypsum -Fiber Roof Board PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 1 per (Optional) SBS-TA, SBS-TA, S 54. min. 2,500 psi min. 1-inch, loose optionally primed with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom 1.0 ftZ SBS SA APP TA APP TA 90.0 structural concrete laid POLYBRITE 745 or WB3000 Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3" Metal Insulation Plate Min. 22 ga., type B, One or more layers, Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Grade 40 steel or any combination, Min. 0.25-inch DensDeck Prime Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast 1 per (Optional) SBS-TA, 565-TA, 5-55. min. 2,500 psi min. 1-inch, loose optionally primed with PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 1.0 ftz SBS-SA gpp_TA APP-TA 97.5 POLYBRITE 745 or WB3000 OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast structural concrete laid #15 EHD Fasteners with Trufast 3" Metal Insulation Plate HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 22 ga., type B, (Optional) One or Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 Grade 33 steel or more layers, any Min. 1.5-inch Polytherm, DP (steel only) or Dekfast #14, OMG AccuTrac Flat Bottom 1 per S-56. min. 2,500 psi combination, loose ACFoam II, H-Shield or Plate with #12 Roofgrip (steel only) or OMG #14 Heavy 2.7 ftZ APP-SA-H (Optional) APP-TA APP-TA -30.0 Polytherm Duty, Trufast 3" Metal Insulation Plate with Trufast #12 structural concrete laid DP (steel only) or Trufast #14 HD Min. 22 ga., type B, One or more layers, Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Grade 40 steel or any combination, Min. 0.25-inch DensDeck Prime Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast 1 per S-57. min. 2,500 psi min. 1-inch, loose optionally primed with PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 2 7 ftZ APP-SA-H (Optional) APP-TA APP-TA -37.5* POLYBRITE 745 or WB3000 OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast structural concrete laid #15 EHD Fasteners with Trufast 3" Metal Insulation Plate NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 47 of 94 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEMTYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No Deck (Note 1) Layer (Note 13) (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Min. 22 ga., type B, One or more layers, Min. 0.25-inch SECUROCK Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast 5-58. Grade 40 steel or any combination, Gypsum -Fiber Roof Board PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 1 per APP-SA-H (Optional)APP-TA APP-TA 37.5 * min. 2,500 psi min. 1-inch, loose optionally primed with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom 2.7 ftz structural concrete laid POLYBRITE 745 or WB3000 Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3" Metal Insulation Plate Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast Min. 22 ga., type B, One or more layers, PLT-H-2-7/8), isofast PLT-S-2-3/4X2-3/4 or Dekfast 5-59. Grade 40 steel or any combination, Min. 0.25-inch DEXcell FA Glass Galvalume Steel 3" Round (aka, Dekfast PLT-R-3) or OMG 1 per APP-SA-H (Optional) APP-TA APP-TA 37.5 * min. 2,500 psi min. 1-inch, loose Mat Roof Board #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal 2.7 ftz structural concrete laid Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3" Metal Insulation Plate Min. 22 ga., type B, (Optional) One or Grade 33 steel or more layers, any Min. 1.5-inch H-Shield or OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel 1 per 5-60. min. 2,500 psi combination, loose Polytherm only) or OMG #14 Heavy Duty, Trufast 3" Metal Insulation Z 2.0 ft APP-SA-H (Optional) APP-TA APP-TA -45.0 * Plate with Trufast #12 DP (steel only) or Trufast #14 HD structural concrete laid HYBRID SYSTEMS WITH SELF -ADHERING SIBS BASE PLY: Min. 22 ga., type B, (Optional) One or Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 Grade 33 steel or more layers, any Min. 1.5-inch Polytherm, DP (steel only) or Dekfast #14, OMG AccuTrac Flat Bottom 1 per 5-61. min. 2,500 psi combination, loose ACFoam II, H-Shield or Plate with #12 Roofgrip (steel only) or OMG #14 Heavy 2 7 ftz SBS-SA-H (Optional) SBS-TA SBS-TA -30.0 Polytherm H Duty, Trufast 3" Metal Insulation Plate with Trufast #12 structural concrete laid DP (steel only) or Trufast #14 HD Min. 22 ga., type B, One or more layers, Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Grade 40 steel or any combination, Min. 0.25-inch DensDeck Prime Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast 1 per 5-62. min. 2,500 psi min. 1-inch, loose optionally primed with PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 2 7 ftz SBS-SA-H (Optional) SBS-TA SBS-TA -37.5* POLYBRITE 745 or WB3000 OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast structural concrete laid #15 EHD Fasteners with Trufast 3" Metal Insulation Plate Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Min. 22 ga., type B, One or more layers, Min. 0.25-inch SECUROCK Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast S 63. Grade 40 steel or any combination, Gypsum -Fiber Roof Board PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 1 per SBS SA H (Optional) SBS TA SBS TA 37.5 * min. 2,500 psi min. 1-inch, loose optionally primed with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom 2.7 ftz structural concrete laid POLYBRITE 745 or WB3000 Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3" Metal Insulation Plate NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 48 of 94 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEMTYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Layer (Note 13) (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast Min. 22 ga., type B, One or more layers, PLT-H-2-7/8), isofast PLT-S-2-3/4X2-3/4 or Dekfast 5-64. Grade 40 steel or any combination, Min. 0.25-inch DEXcell FA Glass Galvalume Steel 3" Round (aka, Dekfast PLT-R-3) or OMG 1 per SBS SA-H (Optional) SBS TA SBS-TA 37.5 * min. 2,500 psi min. 1-inch, loose Mat Roof Board #14 Roofgrip or #15 Roofgrip with OMG 3 in. Round Metal 2.7 ftZ structural concrete laid Plate or Accutrac Flat Bottom Plate or Trufast #14 HD or Trufast #15 EHD Fasteners with Trufast 3" Metal Insulation Plate Min. 22 ga., type B, (Optional) One or Grade 33 steel or more layers, any Min. 1.5-inch H-Shield or OMG AccuTrac Flat Bottom Plate with #12 Roofgrip (steel 1 per 5-65. min. 2,500 psi combination, loose Polytherm H only) #14 Heavy Duty, Trufast 3" Metal Insulation 2 0 ftZ SBS SA-H (Optional) SBS TA SBS-TA 45.0* withh TTrrufast #12 DP (steel only) or Trufast #14 HD Platewith structural concrete laid Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Min. 22 ga., type B, One or more layers, Min. 0.25-inch SECUROCK Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Grade 40 steel or any combination, Gypsum -Fiber Roof Board Galvalume Steel 3" Round (aka, Dekfast PLT-R-3) or OMG 1 per 5-66. min. 2,500 psi min. 1-inch, loose optionally primed with Roofgrip with 3 in. Round Metal Plate, OMG 3 2 0 ftZ SBS-SA-H (Optional) SBS-TA SBS-TA 45.0 in. in. Ribbed Galvalumea Plate (Flat) or Accutrac Flat Bottom structural concrete laid POLYBRITE 745 or WB3000 Plate or Trufast #14 HD Fasteners with Trufast 3" Metal Insulation Plate Min. 22 ga., type B, One or more layers, Polygrip #14 with Polygrip Hex Plate or Dekfast #14 with Grade 40 steel or any combination, Min. 0.25-inch DensDeck Prime Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or OMG #14 1 per 5-67. min. 2,500 psi min. 1-inch, loose optionally primed with Roofgrip with OMG 3 in. Round Metal Plate or Accutrac 2 0 ftZ SBS-SA-H (Optional) SBS-TA SBS-TA -45.0 POLYBRITE 745 or WB3000 Flat Bottom Plate or Trufast #14 HD Fasteners with structural concrete laid Trufast 3" Metal Insulation Plate Min. 22 ga., type B, (Optional) One or Min. 1.5-inch H-Shield or 5-68. Grade 33 steel or more layers, any Polytherm optionally primed Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 1 per SBS-SA-H (Optional) SBS-TA SBS-TA 60.0 min. 2,500 psi combination, loose DP (steel only) or Dekfast #14 2.0 ftz with POLYBRITE 745 or WB3000 structural concrete laid Min. 22 ga., type B, Min. 0.25-inch DensDeck Prime OMG 3 in. Galvalume Plate (non -ribbed) with #12 Grade 40 steel or One or more layers, or SECUROCK Gypsum -Fiber Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex 1 per S-69. min. 2,500 psi any combination, Roof Board optionally primed (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel 1.6 ftz SBS-SA-H (Optional) SBS-TA SBS-TA -60.0 loose laid only) or Dekfast #14, Trufast 3" Metal Insulation Plate structural concrete with POLYBRITE 745 or WB3000 with Trufast #12 DP (steel only) or Trufast #14 HD Min. 1.5-inch ACFoam II, ACFoam III, EnergyGuard Polyiso Dekfast Hex (aka, Dekfast PLT-H-2-7/8) or Dekfast Min. 22 ga., type B, (Optional) One or Insulation, ENRGY 3, ENRGY 3 Galvalume Steel 3" Round Insulation Plate (aka, Dekfast Grade 33 steel or more layers, any CGF, H-Shield, H-Shield CG, ISO PLT-R-3) with Dekfast #12 (steel only) or Dekfast #14, 1 per S-70. min. 2,500 psi combination, loose 95+ GL, Multi -Max FA3, OMG 3 in. Galvalume Plate (non -ribbed) or OMG 1.3 ftz SBS-SA-H (Optional) SBS-TA SBS-TA -67.5* AccuTrac Plate with #12 Roofgrip (steel only) or OMG #14 structural concrete laid Polytherm or Ultra -Max Heavy Duty or Trufast 3" Metal Insulation Plate with optionally primed with Trufast #12 DP (steel only) or Trufast #14 HD POLYBRITE 745 or WB3000 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.3654-1127 Revision 25: 09/30/2020 Appendix 1, Page 49 of 94 NNEMO I etc. TABLE 213: STEEL OR STRUCTURAL CONCRETE DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER BONDEDSYSTEMTYPEC-1: MECHANICALLY ATTACHED INSULATION, ROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No Deck (Note 1) Layer (Note 13) (psf) Type Fasten (Note 11) Attach Base Ply Ply Cap Ply Min. 22 ga., type B, Min. 0.25-inch DensDeck Prime OMG 3 in. Galvalume Plate (non -ribbed) with #12 Grade 40 steel or One or more layers, or SECUROCK Gypsum -Fiber Roofgrip (steel only) or OMG #14 Heavy Duty, Dekfast Hex 1 per S-71. min. 2,500 psi any combination, Roof Board optionally primed (aka, Dekfast PLT-H-2-7/8) with Dekfast #12 DP (steel 1.3 ftz SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 loose laid only) or Dekfast #14, Trufast 3" Metal Insulation Plate structural concrete with POLYBRITE 745 or WB3000 with Trufast #12 DP (steel only) or Trufast #14 HD Min. 22 ga., type B, (Optional) One or S 72 Grade 33 steel or more layers, any Min. 0.5-inch SECUROCK OMG 3-inch Galvalume Steel Plate with OMG #14 HD 1 per SBS-SA-H (Optional) SBS-TA SBS-TA -75.0 min. 2,500 psi combination, loose Gypsum -Fiber Roof Board 1.8 ftZ structural concrete laid Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Min. 22 ga., type B, One or more layers, Min. 0.25-inch SECUROCK Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast 5-73. Grade 40 steel or any combination, Gypsum -Fiber Roof Board PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with 1 per SBS-SA-H (Optional) SBS-TA SBS-TA 90.0 min. 2,500 psi min. 1-inch, loose optionally primed with OMG 3 in. Round Metal Plate or Accutrac Flat Bottom 1.0 ftZ structural concrete laid POLYBRITE 745 or WB3000 Plate or Trufast #14HD or Trufast #15 EHD Fasteners with Trufast 3" Metal Insulation Plate Min. 22 ga., type B, One or more layers, Polygrip #14 or Polygrip #15 with Polygrip Hex Plate or Grade 40 steel or any combination, Min. 0.25-inch DensDeck Prime Dekfast DF-#14 or DF-#15 with Dekfast Hex (aka, Dekfast 1 per S-74. min. 2,500 psi min. 1-inch, loose optionally primed with PLT-H-2-7/8) or OMG #14 Roofgrip or #15 Roofgrip with Z 1.0 ft SBS-SA-H (Optional) SBS-TA SBS-TA -97.5 POLYBRITE 745 or WB3000 OMG 3 in. Round Metal Plate or Trufast #14 HD or Trufast structural concrete laid #15 EHD Fasteners with Trufast 3" Metal Insulation Plate COLD -APPLIED BASE PLY: Min. 22 ga., type B, One or more layers, Min. 0.25-inch DensDeck Prime Dekfast Galvalume Steel Hex with Dekfast #14, OMG 3" SBS-CAI, 5 75. Grade 33 steel or any combination, or SECUROCK Gypsum -Fiber Galvalume Ribbed Plates with OMG #14 RoofGrip or 1 per SBS-CA1, (Optional) SBS- SBS CA2, 45.0* min. 2,500 psi Trufast 3" Metal Insulation Plates with Trufast #14 HD 2.0 ftz SBS-CA2 CAI, SBS-CA2 structural concrete loose laid Roof Board Fasteners APP-CA1 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 50 of 94 NNEMO I etc. ORREROOF (TEAR -OFF) OR RECOVER ��SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Insulation Layer(s) System Deck Base Sheet Roof Cover (Note 15) MDP (Note 13) No. (Note 1) (Psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply ASPHALT- OR TORCH -APPLIED BASE PLY: Min. 22 ga., type B, Elastobase, Roofgrip #14 with OMG Flat Bottom Plates 12-inch o.c. at min. 4-inch lap (Optional) BP - Grade 33 steel or min. One or more Prelim. Elastobase P, (square), Dekfast #14 with Dekfast Hex (aka, and 18-inch o.c. at two, AA, SBS-AA, SBS-AA, SBS- 5-76. 2,500 psi structural layers, any Attached Elastovent or JM Dekfast PLT-H-2-7/8) or Trufast #14 HD with equally spaced, staggered SBS-TA or TA, APP-TA -45.0* combination concrete Perma-Ply 28 Trufast 3" Metal Insulation Plate center rows APP-TA Elastobase, Elastobase Min. 22 ga., type B, P, Elastovent, Roofgrip #14 with OMG Flat Bottom Plates 12-inch o.c. at min. 4-inch lap (Optional) BP - Grade 33 steel or min. One or more Prelim. Polyglass G2 Base, (square), Dekfast #14 with Dekfast Hex (aka, and 12-inch o.c. at two, AA, SBS AA, SBS-AA, SBS- 5-77. 2,500 psi structural layers, any Attached CertainTeed Glasbase, Dekfast PLT-H-2-7/8) or Trufast #14 HD with equally spaced, staggered SBS-TA or TA, APP-TA -52.5 Combination Firestone MB Base, JM concrete Perma-Ply 28 or Trufast 3" Metal Insulation Plate center rows APP-TA GAFGLAS #75 Min. 22 ga., type B, 12-inch o.c. at min. 4-inch lap (Optional) BP - Grade 33 steel or min. One or more Prelim. Elastobase, Roofgrip #12 (steel only) or #14 with OMG Flat and 12-inch o.c. at two, AA, SBS-AA, SBS-AA, SBS S 78. 2,500 psi structural layers, any Attached Elastobase P or Bottom Plates (square) equally spaced, staggered SBS-TA or TA, APP-TA 60.0 combination Elastovent concrete center rows APP-TA Min. 22 ga., type B, 12-inch o.c. at the min. 4-inch (Optional) BP - One or more Dekfast #14 with Dekfast Hex (aka, Dekfast PLT-H- 5-79. Grade 33 steel or min. layers, any Prelim. Polybond, Polyflex 2-7/8) or OMG Roofgrip #14 OMG Flat Bottom lap and 18-inch o.c. at two, AA, SBS-AA, SBS-AA, SBS- -112.5 2,500 psi structural Attached equally spaced, staggered SBS-TA or TA, APP-TA concrete combination Plates center rows APP-TA SELF -ADHERING BASE PLY: Min. 22 ga., type B, One or more Elastobase or Roofgrip #14 with OMG Flat Bottom Plates 12-inch o.c. at min. 4-inch lap SBS-SA, APP- Grade 33 steel or min. Prelim. (square), Dekfast #14 with Dekfast Hex (aka, and 12-inch o.c. at two, 5-80. 2,500 psi structural layers, any Attached Elastobase P with Dekfast PLT-H-2-7/8) or Trufast #14 HD with equally spaced, staggered SBS-SA SA, SBS-TA -52.5* concrete combination poly top surface Trufast 3" Metal Insulation Plate center rows or APP-TA Min. 22 ga., type B, One or more Elastobase or 12-inch o.c. at min. 4-inch lap SBS-SA, APP- Grade 33 steel or min. Prelim. Roofgrip #12 (steel only) or #14 with OMG Flat and 12-inch o.c. at two, 5-81. 2,500 psi structural layers, any Attached Elastobase P with Bottom Plates (square) equally spaced, staggered SBS-SA SA, SBS-TA -60.0* combination poly top surface or APP-TA concrete I I I I center rows HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 22 ga., type B, One or more Elastobase or Roofgrip #14 with OMG Flat Bottom Plates 12-inch o.c. at min. 4-inch lap Grade 33 steel or min. Prelim. (square), Dekfast #14 with Dekfast Hex (aka, and 12-inch o.c. at two, S 82. 2,500 psi structural layers, any Attached Elastobase P with Dekfast PLT-H-2-7/8) or Trufast #14 HD with equally spaced, staggered APP-SA-H APP-TA 52.5* combination poly top surface concrete Trufast 3" Metal Insulation Plate center rows NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 51 of 94 NNEMO I etc. 000EEF___1L ORREROOF (TEAR -OFF) OR RECOVER ,;i..SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Insulation Layer(s) System Deck Base Sheet Roof Cover (Note 15) MDP (Note 13) No. (Note 1) (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply Min. 22 ga., type B, One or more Elastobase or 12-inch o.c. at min. 4-inch lap Grade 33 steel or min. Prelim. Roofgrip #12 (steel only) or #14 with OMG Flat and 12-inch o.c. at two, 5-83. 2,500 psi structural layers, any Attached Elastobase P with Bottom Plates (square) equally spaced, staggered APP-SA-H APP-TA 60.0* combination poly top surface concrete center rows HYBRID SYSTEMS WITH SELF -ADHERING SIBS BASE PLY: Min. 22 ga., type B, One or more Elastobase or Roofgrip #14 with OMG Flat Bottom Plates 12-inch o.c. at min. 4-inch lap Grade 33 steel or min. Prelim. (square), Dekfast #14 with Dekfast Hex (aka, and 12-inch o.c. at two, 5-84. 2,500 psi structural layers, any Attached Elastobase P with Dekfast PLT-H-2-7/8) or Trufast #14 HD with equally spaced, staggered SBS-SA-H SBS-TA -52.5* concrete combination poly top surface Trufast 3" Metal Insulation Plate center rows Min. 22 ga., type B, One or more Elastobase or 12-inch o.c. at min. 4-inch lap Grade 33 steel or min. Prelim. Roofgrip #12 (steel only) or #14 with OMG Flat and 12-inch o.c. at two, 5-85. 2,500 psi structural layers, any Attached Elastobase P with Bottom Plates (square) equally spaced, staggered SBS-SA-H SBS TA 60.0* combination poly top surface concrete center rows COLD -APPLIED BASE PLY: Min. 22 ga., type B, One or more 12-inch o.c. at min. 4-inch lap (Optional) SBS-CA1, S-86. Grade 33 steel or min. layers, any Loose Elastobase Trufast #12 DP (steel only), #14 HD or #15 EHD and 12-inch o.c. at one SBS-CA1, SBS- SBS-CA2, -45.0* 2,500 psi structural combination laid with Trufast 3" Metal Insulation Plate staggered center row CA2 APP-CA1 concrete Min. 22 ga., type B, One or more 12-inch o.c. at min. 4-inch lap S 87. Grade 33 steel or min. layers, any Loose Elastovent Trufast #12 DP (steel only), #14 HD or #15 EHD and 12-inch o.c. at one (Optional) SBS-CA1, 45.0* 2,500 psi structural laid with Trufast 3" Metal Insulation Plate SBS-CA1 APP-CA1 combination staggered center row concrete Min. 22 ga., type B, One or more 12-inch o.c. at min. 4-inch lap (Optional) SBS-CA1, Grade 33 steel or min. Loose Trufast #12 DP (steel only), #14 HD or #15 EHD and 12-inch o.c. at two, 5-88. 2,500 psi structural layers, any laid Elastobase with Trufast 3" Metal Insulation Plate equally spaced, staggered SBS-CAl, SBS- SBS-CA2, -67.5 combination CA2 APP-CA1 concrete center rows Min. 22 ga., type B, 12-inch o.c. at min. 4-inch lap Grade 33 steel or min. One or more Loose Trufast #12 DP (steel only), #14 HD or #15 EHD and 12-inch o.c. at two, (Optional) SBS-CA1, S 89. 2,500 psi structural layers, any laid Elastovent with Trufast 3" Metal Insulation Plate equally spaced, staggered SBS-CA1 APP-CA1 67.5 combination concrete center rows (Optional) Min. 22 ga., type B, One or more 6-inch o.c. at min. 4-inch lap Elastoflex S6 Grade 40 steel or min. Loose Trufast #12 DP (steel only) or Trufast #14 HD (steel S-90. 2,500 psi structural layers, any laid Elastoflex S6 or concrete) with Trufast 3" Metal Insulation Plate and 6-inch o.c. at one applied in SBS-CA1 -75.0* combination staggered center row PG350 at 1.5- concrete 2.0 gal/square NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-1127 Revision 25: 09/30/2020 Appendix 1, Page 52 of 94 NNEMO I etc. 000EU7___1=L ORREROOF (TEAR -OFF) OR RECOVER ,;i..SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER Insulation Layer(s) System Deck Base Sheet Roof Cover (Note 15) MDP (Note 13) No. (Note 1) (Psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply (Optional) Min. 22 ga., type B, One or more 12-inch o.c. at min. 4-inch lap Elastoflex S6 Grade 40 steel or min. Loose- Trufast #12 DP (steel only) or Trufast #14 HD (steel and 12-inch o.c. at two, S-91. 2,500 psi structural layers, any laid Elastoflex S6 or concrete) with Trufast 3" Metal Insulation Plate equally spaced, staggered applied in SBS-CA1 -90.0* combination PG350 at 1.5- concrete center rows 2.0 gal/square LE 2D: STEEL OR STRUCTURAL CONCRETE DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED VELOCIFLEX, BONDED ROOF COVER Insulation Layer(s) System Deck Base Sheet Roof Cover (Note 15) MDP (Note 13) No. (Note 1) ( Psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply ASPHALT- OR TORCH -APPLIED BASE PLY: Min. 22 ga., type B, 40 One or more Prelim. Trufast #14 HD with Trufast 2" Barbed Seam 18-inch o.c. within the 4-inch (Optional) S-92. ksi steel or min. 2,500 layers, any Elastoflex S6 wide, torch -sealed or heat- SBS-TA -30.0 psi structural concrete combination Attached Plates welded side laps SBS-TA Trufast #15 EHD (steel only) or Trufast #14 HD (concrete Min. 22 ga., type B, only) with Trufast 2.4" Barbed Metal Seam Plates, Trufast Grade 40 steel or min. One or more Prelim. 2.4" Scoop Seam Plates or Trufast 2.75" Barbed Metal 18-inch o.c. within the 5-inch (Optional) 5-93. 2,500 psi structural layers, any Attached Elastoshield HT Seam Plates or Dekfast #15 with Dekfast Galvalume Steel wide, torch -sealed or heat- SBS-TA SBS-TA -37.5 combination 1-1/2" x 2-3/4" Oval Barbed Plate aka, Dekfast PLT-02- ( welded side laps concrete 3/4-12B) or Dekfast Galvalume Steel 2-3/8" Round Barbed Plate (aka, Dekfast PLT-R-2-3/8-613) Min. 22 ga., type B, 33 One or more Trufast #15 EHD (steel only) or Trufast #14 HD 12-inch o.c. within the 5-inch 5-94. ksi steel or min. 2,500 layers, any Prelim. Elastoflex S6 (concrete only) with Trufast 2.4" Scoop Seam wide, torch -sealed or heat- (Optional) SBS-TA -45.0 psi structural concrete combination Attached Plates or Trufast 2.75" Barbed Metal Seam Plates welded side laps SBS TA Min. 22 ga., type B, 33 One or more Prelim. Trufast #15 EHD (steel only) or Trufast #14 HD 6-inch o.c. within the 5-inch (Optional) S-95. ksi steel or min. 2,500 layers, any Elastoflex S6 (concrete only) with Trufast 2.75" Barbed Metal wide, torch -sealed or heat SBS-TA -60.0 psi structural concrete combination Attached Seam Plates welded side laps SBS-TA Min. 22 ga., type B, One or more Trufast #15 EHD (steel only) or Trufast #14 HD 18-inch o.c. within the 5-inch Grade 40 steel or min. Prelim. (Optional) SBS-TA 5-96. 2,500 psi structural layers, any Attached Elastoflex S6 HP (concrete only) with Trufast 2.75" Barbed Metal wide, torch -sealed or heat- SBS-TA (D6164 only) -60.0 combination Seam Plates welded side laps concrete Min. 22 ga., type B, 33 One or more Prelim. Trufast #15 EHD (steel only) or Trufast #14 HD 12-inch o.c. within the 5-inch (Optional) SBS-TA 5-97. ksi steel or min. 2,500 layers, any Elastoflex S6 HP (concrete only) with Trufast 2.75" Barbed Metal wide, torch -sealed or heat- -82.5 Attached SBS-TA (D6164 only) psi structural concrete combination Seam Plates welded side laps NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 53 of 94 NNEMO I etc. TABLE213: STEEL OR STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER mommolSYS1 EM TYPE D-2: INSULATED, MECHANICALLY ATTACHED VELOCI FLEX, BONDED ROOF COVER Insulation Layer(s) System Deck Base Sheet Roof Cover (Note 15) MDP (Note 13) No. (Note 1) (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4" Barbed Metal Seam Plates, Trufast Min. 22 ga., type B, 33 One or more Prelim. 2.4" Scoop Seam Plates or Trufast 2.75" Barbed Metal 12-inch o.c. within the 5-inch (Optional) SBS-TA S-98. ksi steel or min. 2,500 layers, any Attached Elastoshield HT Seam Plates or Dekfast #15 with Dekfast Galvalume Steel wide, torch -sealed or heat SBS-TA (D6164 only) -82.5 psi structural concrete combination 1-1/2" x 2-3/4" Oval Barbed Plate (aka, Dekfast PLT-02- welded side laps 3/4-12B) or Dekfast Galvalume Steel 2-3/8" Round Barbed Plate (aka, Dekfast PLT-R-2-3/8-66) Min. 22 ga., type B, One or more Prelim. Dekfast #15 HS with Dekfast Galvalume Steel 2- 12-inch o.c. within the 5-inch (Optional) SBS-TA, APP- S 99. layers, any Polyflex 3/8" Round Barbed Plate (aka, Dekfast PLT-R-2- 82.5 Grade 80 steel combination Attached 3/8-66) wide, torch -sealed side lap APP-TA TA Min. 22 ga., type B, One or more Trufast #15 EHD (steel only) or Trufast #14 HD Grade 80 steel or min. Prelim. Polybond or 12-inch o.c. within the 6-inch (Optional) SBS-TA, APP- 5-100. 2,500 psi structural layers, any Attached Polyflex (concrete only) with Trufast 2.4 in. Barbed Seam wide, torch -sealed side lap APP-TA TA 82.5 combination Plates concrete Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4" Barbed Metal Seam Plates, Trufast Min. 22 ga., type B, 40 One or more Prelim. 2.4" Scoop Seam Plates or Trufast 2.75" Barbed Metal 6-inch o.c. within the 5-inch (Optional) SBS-TA S-101. ksi steel or min. 2,500 layers, any Attached Elastoshield HT Seam Plates or Dekfast #15 with Dekfast Galvalume Steel wide, torch -sealed or heat- SBS-TA (D6164 only) -97.5 psi structural concrete combination 1-1/2" x 2-3/4" Oval Barbed Plate aka, Dekfast PLT-02- ( welded side laps 3/4-12B) or Dekfast Galvalume Steel 2-3/8" Round Barbed Plate (aka, Dekfast PLT-R-2-3/8-66) Min. 22 ga., type B, One or more Trufast #15 EHD (steel only) or Trufast #14 HD 6-inch o.c. within the 5-inch 5-102. Grade 40 steel or min. layers, any Prelim. Elastoflex S6 HP (concrete only) with Trufast 2.75" Barbed Metal wide, torch -sealed or heat- (Optional) SBS-TA -135.0 2,500 psi structural Attached SBS-TA (D6164 only) combination Seam Plates welded side laps concrete COLD -APPLIED BASE PLY: (Optional) Min. 22 ga., type B, 40 One or more Trufast #15 EHD (steel only) or Trufast #14 HD 18-inch o.c. within the 5-inch Elastoflex S6 ksi steel or min. 2,500 layers, any Prelim. Elastoflex S6 HP (concrete only) with Trufast 2.75" Barbed Metal wide, torch -sealed or heat- applied in SBS-CA1 -60.0 psi structural concrete combination Attached Seam Plates welded side laps PG350 at 1.5- S-103. 2.0 gal/square Note: When extrapolating base sheet attachment for this system for elevated pressure zones, any additional fastener rows installed in the center of the sheet shall be stripped -in with minimum 6-inch wide strips of torch -applied, sand -top -surfaced, Polyglass SBS modified bitumen membrane prior to placement of subsequent Base Ply or Cap Ply membranes in PG350 adhesive. NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 54 of 94 NNEMO I etc. TABLE213: STEEL OR STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER mommoiSYS1 EM TYPE D-2: INSULATED, MECHANICALLY ATTACHED VELOCI FLEX, BONDED ROOF COVER Insulation Layer(s) System Deck Base Sheet Roof Cover (Note 15) MDP (Note 13) No. (Note 1) (psf) Type Attach Type Fasten (Note 11) Attach Base Ply Cap Ply (Optional) Min. 22 ga., type B, 40 One or more Trufast #15 EHD (steel only) or Trufast #14 HD 12-inch o.c. within the 5-inch Elastoflex S6 ksi steel or min. 2,500 layers, any Prelim. Elastoflex S6 HP (concrete only) with Trufast 2.75" Barbed Metal wide, torch -sealed or heat- applied in SBS-CA1 -82.5 psi structural concrete combination Attached Seam Plates welded side laps PG350 at 1.5- 5-104. 2.0 gal/square Note: When extrapolating base sheet attachment for this system for elevated pressure zones, any additional fastener rows installed in the center of the sheet shall be stripped -in with minimum 6-inch wide strips of torch -applied, sand -top -surfaced, Polyglass SBS modified bitumen membrane prior to placement of subsequent Base Ply or Cap Ply membranes in PG350 adhesive. NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 55 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) Deck System No. (Note 1) Primer Type Attach Type Attach Base Ply Ply MDP Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) ASPHALT OR TORCH APPLIED BASE PLY: Structural Min. 2-inch Polytherm, ACFoam II, Min. 0.25-inch SECUROCK (Optional) BP -AA, C-1 concrete None Polytherm H or H-Shield D-IS Gypsum -Fiber Roof Board D-IS BP -AA, SBS-AA SBS-AA SBS-AA -225.0 (Optional) Min. 1.5-inch Polytherm, Structural SBS-TA, APP- (Optional) SBS-TA, C 2 None ACFoam II, Polytherm G, ACFoam III, D-IS Min. 0.25-inch DensDeck Prime D-IS SBS-TA, APP-TA -282.5 concrete Polytherm H, H-Shield TA APP-TA (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural SBS-TA, APP- (Optional) SBS-TA, C-3 None ACFoam II, Polytherm G, ACFoam III, D-IS Gypsum -Fiber Roof Board or D-IS SBS-TA, APP-TA -322.5 concrete Polytherm H, H-Shield DEXcell FA Glass Mat Roof Board TA APP-TA Structural Min. 2-inch Polytherm, ACFoam II, Min. 0.25-inch SECUROCK (Optional) BP -AA, C-4 concrete None Polytherm H or H-Shield OB500 Gypsum -Fiber Roof Board OB500 BP -AA, SBS-AA SBS-AA SBS-AA -225.0 (Optional) Min. 1.5-inch Polytherm, Structural SBS-TA, APP- (Optional) SBS-TA, C-5 None ACFoam II, Polytherm G, ACFoam III, OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-TA, APP-TA -282.5 concrete Polytherm H, H-Shield TA APP-TA (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural SBS-TA, APP- (Optional) SBS-TA, C-6 None ACFoam II, Polytherm G, ACFoam III, OB500 Gypsum -Fiber Roof Board or OB500 SBS-TA, APP-TA -322.5 concrete Polytherm H, H-Shield DEXcell FA Glass Mat Roof Board TA APP-TA Structural Min. 2-inch Polytherm, ACFoam II, M-OSFA or Min. 0.25-inch SECUROCK M-OSFA or (Optional) BP -AA, C 7 concrete None Polytherm H or H-Shield M-PG1 Gypsum -Fiber Roof Board M-PG1 BP -AA, SBS-AA SBS-AA SBS-AA 225.0 (Optional) Min. 1.5-inch Polytherm, Structural M-OSFA or M-OSFA or SBS-TA, APP- (Optional) SBS-TA, C 8 None ACFoam II, Polytherm G, ACFoam III, Min. 0.25-inch DensDeck Prime SBS-TA, APP-TA -282.5 concrete Polytherm H, H-Shield M-PG1 M-PG1 TA APP-TA (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural M-OSFA or M-OSFA or SBS-TA, APP- (Optional) SBS-TA, C-9 None ACFoam II, Polytherm G, ACFoam III, Gypsum -Fiber Roof Board or SBS-TA, APP-TA -322.5 concrete Polytherm H, H-Shield M-PG3 DEXcell FA Glass Mat Roof Board M-PG1 TA APP-TA Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Structural min. 1.3-inch Polytherm G, ACFoam III or Min. 0.25-inch SECUROCK (Optional) BP -AA, C-10 concrete None min. 1.0-inch ISO 95+GL, Polytherm H, H- CR-20 Gypsum -Fiber Roof Board CR-20 BP -AA, SBS AA SBS-AA SBS-AA 225.0 Shield, H-Shield CG or ENRGY 3 Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Structural min. 1.3-inch Polytherm G, ACFoam III or Min. 0.25-inch SECUROCK C-11 None CR-20 CR-20 APP TA (Optional) APP-TA APP-TA 232.5 concrete min. 1.0-inch ISO 95+GL, Polytherm H, H- Gypsum -Fiber Roof Board Shield, H-Shield CG or ENRGY 3 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 56 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) (Optional) Min. 1.5-inch Polytherm, C-12 Structural None ACFoam II, Polytherm G, ACFoam III, CR-20 Min. 0.25-inch DensDeck Prime CR-20 SBS-TA, APP- (Optional) SBS-TA, SBS-TA, APP-TA -282.5 concrete Polytherm H, H-Shield TA APP TA Structural (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK SBS-TA, APP- (Optional) SBS-TA, C-13 None ACFoam II, Polytherm G, ACFoam III, CR-20 Gypsum -Fiber Roof Board or CR-20 SBS-TA, APP-TA -322.5 concrete Polytherm H, H-Shield DEXcell FA Glass Mat Roof Board TA APP-TA Structural (Optional) Min. 2-inch Polytherm, ACFoam OB Classic Min. 0.25-inch SECUROCK OB Classic (Optional) BP -AA, C-14 concrete None Il, Polytherm H or H-Shield (full- Gypsum -Fiber Roof Board (full- BP -AA, SBS-AA SBS-AA SBS-AA -225.0 coverage) coverage) Structural (Optional) Min. 2-inch Polytherm, ACFoam OB Classic Min. 0.25-inch SECUROCK OB Classic C-15 None (full- (full- APP-TA (Optional) APP-TA APP-TA -232.5 concrete II, Polytherm H or H-Shield coverage) Gypsum -Fiber Roof Board coverage) Min. 1.5-inch Polytherm, ACFoam II, Structural Polytherm G, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK (Optional) BP -AA, C-16 concrete PG100 Polytherm H, H-Shield, H-Shield CG or Hot asphalt Gypsum -Fiber Roof Board Hot asphalt BP -AA, SBS-AA SBS AA SBS-AA 225.0 Multi -Max FA3 Min. 1.5-inch Polytherm, ACFoam II, Structural Polytherm G, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK C-17 concrete PG100 Polytherm H, H-Shield, H-Shield CG or Hot asphalt Gypsum -Fiber Roof Board Hot asphalt APP-TA (Optional) APP-TA APP-TA -232.5 Multi -Max FA3 (Optional if (Optional if using AA C-18 Structural PG100 Min. 0.75-inch Fesco Board (homogeneous) Hot asphalt None N/A using AA Ply) Base) BP -AA, SBS-AA, SBS-AA, SBS-TA, 277.5 concrete BP -AA, SBS-AA SBS-TA or APP-TA APP TA Min. 1.5-inch Polytherm, ACFoam II, (Optional if (Optional if using AA C-19 Structural PG100 Polytherm G, ACFoam III, ENRGY 3, Hot asphalt Min. 0.75-inch Fesco Board Hot asphalt using AA Ply) Base) BP -AA, SBS-AA, SBS-AA, SBS-TA, 290.0 concrete Polytherm H, H-Shield, H-Shield CG or (homogeneous) APP TA Multi -Max FA3 BP -AA, SBS-AA SBS-TA or APP-TA (Optional if (Optional if using AASBS-AA, C-20 Structural PG100 Min. 0.5-inch Structodek High Density Hot asphalt None N/A using AA Ply) Base) BP -AA, SBS-AA, SBS-TA, 285.0 concrete Fiberboard Roof Insulation BP -AA, SBS-AA SBS-TA or APP-TA APP TA Min. 1.5-inch Polytherm, ACFoam II, Min. 0.5-inch Structodek High (Optional if onal if using AA C-21 Structural PG100 Polytherm G, ACFoam III, ENRGY 3, Hot asphalt Density Fiberboard Roof Hot asphalt using AA Ply)BP-AA, FBapse)SBS-AA, SBS-AA, SBS-TA, 480.0 concrete Polytherm H, H-Shield, H-Shield CG or Insulation BP -AA, SBS-AAA or APP-TA APP TA Multi -Max FA3 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 57 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Min. 1.5-inch Polytherm, ACFoam II, (Optional if (Optional if using AA Structural Polytherm G, ACFoam III, ENRGY 3, SBS-AA, SBS-TA, C 22 PG100 Hot asphalt Min. 0.25-inch DensDeck Prime Hot asphalt using AA Ply) Base) BP -AA, SBS-AA, 480.0 concrete Polytherm H, H-Shield, H-Shield CG or APP TA Multi -Max FA3 BP -AA, SBS-AA SBS-TA or APP-TA (Optional if (Optional if using AA Structural SBS-AA, SBS-TA, C-23 PG100 Min. 0.25-inch DensDeck Prime Hot asphalt None N/A using AA Ply) Base) BP -AA, SBS-AA, 510.0 concrete BP -AA, SBS-AA SBS-TA or APP-TA APP TA SELF -ADHERING BASE PLY TO INSULATION: Structural (Optiona (Optional) additional layers(s) of (Optional) SBS-SA, SBS-SA, APP-SA, C 24 Min. 1.5-inch H-Shield or Multi -Max FA3 D-IS D-IS SBS-SA 67.5 concrete 1) PG100 base insulation SBS-TA, APP-TA SBS-TA, APP-TA Structural (Optional) additional layers(s) of (Optional) SBS-TA, C-25 None Min. 1.5-inch Polytherm H, H-Shield D-IS D-IS SBS-SA 56S-TA, APP-TA 122.5 concrete base insulation APP TA Structural (Optiona Min. 1.5-inch Polytherm, ACFoam 11 or (Optional) additional layers(s) of (Optional) SBS-SA, SBS-SA, APP-SA, C-26 concrete 1) PG100 ENRGY 3 D-IS base insulation D-IS SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA -135.0 Structural (Optional) additional layers of C 27 None Min. 1.5-inch, min. 1.5 pcf Insulfoam D-IS D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA 157.5 concrete base insulation Structural (Optional) additional layers of C 28 None Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 OB500 SBS-SA (Optional) SBS SA SBS SA, APP SA 120.0 concrete base insulation Structural (Optional) additional layers(s) of (Optional) SBS-TA, C 29 None Min. 1.5 inch Polytherm, ACFoam II OB500 OB500 SBS-SA SBS TA, APP-TA 122.5 concrete base insulation APP-TA Structural (Optional) additional layers(s) of (Optional) SBS-SA, SBS-SA, APP-SA, C-30 None Min. 1.5-inch ENRGY 3 OB500 OB500 SBS-SA -127.5 concrete base insulation SBS-TA, APP-TA SBS-TA, APP-TA Structural (Optional) additional layers(s) of (Optional) SBS-SA, SBS-SA, APP-SA, C-31 None Min. 1.5-inch Polytherm H or H-Shield OB500 OB500 SBS-SA 150.0 concrete base insulation SBS-TA, APP-TA SBS-TA, APP-TA Min. 1.5-inch Polytherm, ACFoam 11, Structural M-OSFA or (Optional) additional layers(s) of M-OSFA or (Optional) SBS-TA, C-32 None Polytherm G, ACFoam III, Polytherm H, H- SBS-SA SBS-TA, APP-TA -122.5 concrete Shield M-PG1 base insulation M-PG1 APP TA Structural Min. 1.5-inch Polytherm, ACFoam II, (Optional) additional layers(s) of (Optional) SBS-SA, SBS-SA, APP-SA, C-33 concrete None ENRGY 3, H-Shield or Multi -Max FA3 M-OSFA base insulation M-OSFA SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA _232.5 Min. 1-inch Polytherm, ACFoam 11, (Optional) additional layers(s) of Polytherm G, ACFoam 111, EnergyGuard Structural M-OSFA or base insulation, optionally M-OSFA or SBS-CA1, SBS- C-34 None Polyiso Insulation, ENRGY 3, Polytherm H, SBS-SA None -290.0 concrete M-PG1 primed with POLYBRITE 745 or M-PG1 CA2 H-Shield, ISO 95+ GL, Multi -Max FA3, RESISTA or UltraMax. WB3000 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 58 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System Deck MDP No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Structural Min. 1.5-inch Polytherm, ACFoam II, (Optional) additional layers(s) of (Optional) SBS-TA, C-35 concrete None Polytherm H, H-Shield CR-20 base insulation CR-20 SBS-SA APP TA SBS-TA, APP-TA 122.5 Structural (Optional) additional layers of C 36 concrete None Min. 1.5 inch, min. 2.0 pcf Insulfoam CR-20 base insulation CR-20 SBS SA (Optional) SBS SA SBS SA, APP-SA 240.0 OB Classic Structural Min. 2-inch Polytherm, ACFoam II, (Optional) additional layers(s) of OB Classic (Optional) SBS-SA, SBS-SA, APP-SA, concrete Polytherm H or H-Shield base insulation SBS-TA, APP-TA SBS-TA, APP-TA C-37 None (full- (full- SBS-SA 270.0 coverage) coverage) Min. 1.5-inch Polytherm, ACFoam II, Structural Polytherm G, ACFoam III, ENRGY 3, (Optional) additional layers(s) of (Optional) SBS-SA, SBS-SA, APP-SA, C-38 concrete PG100 Polytherm H, H-Shield, H-Shield CG or Hot asphalt base insulation Hot asphalt SBS SA SBS-TA, APP-TA SBS-TA, APP-TA 480.0 Multi -Max FA3 HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY TO INSULATION: Structural (Options (Optional) additional layers(s) of C-39 concrete 1) PG100 Min. 1.5-inch H-Shield or Multi -Max FA3 D-IS base insulation D-IS APP-SA-H (Optional) APP-TA APP-TA 67.5 Structural (Optional) additional layers(s) of C-40 concrete None Min. 1.5-inch Polytherm H, H-Shield D-IS base insulation D-IS APP-SA-H (Optional) APP-TA APP-TA 122.5 Structural (Optiona Min. 1.5-inch Polytherm, ACFoam II or (Optional) additional layers(s) of C 41 concrete I) PG100 ENRGY 3 D-IS base insulation D-IS APP-SA-H (Optional) APP-TA APP TA 135.0 C-42 Structural None Min. 1.5-inch Polytherm, ACFoam II OB500 (Optional) additional layers(s) of OB500 APP-SA-H (Optional) APP-TA APP-TA -122.5 concrete base insulation Structural (Optional) additional layers(s) of C-43 concrete None Min. 1.5-inch ENRGY 3 OB500 base insulation OB500 APP-SA-H (Optional) APP-TA APP-TA 127.5 Structural (Optional) additional layers(s) of C-44 None Min. 1.5-inch Polytherm H or H-Shield OB500 OB500 APP-SA-H (Optional) APP-TA APP-TA 150.0 concrete base insulation Min. 1.5-inch Polytherm, ACFoam II, Structural M-OSFA or (Optional) additional layers(s) of M-OSFA or C-45 concrete None Polytherm G, ACFoam III, Polytherm H, H- M-PG1 base insulation M-PG1 APP-SA-H (Optional) APP-TA APP-TA -122.5 Shield Structural Min. 1.5-inch Polytherm, ACFoam II, (Optional) additional layers(s) of C-46 concrete None ENRGY 3, H-Shield or Multi -Max FA3 M-OSFA base insulation M-OSFA APP-SA-H (Optional) APP-TA APP-TA 232.5 Structural Min. 1.5-inch Polytherm, ACFoam 11, (Optional) additional layers(s) of C 47 concrete None Polytherm H, H-Shield CR-20 base insulation CR-20 APP-SA-H (Optional) APP-TA APP-TA 122.5 Structural None Min. 2-inch Polytherm, ACFoam II, OB Classic (Optional) OB Classic C-48 (full- additional layers(s) of (full- APP-SA-H (Optional) APP-TA APP-TA -270.0 concrete Polytherm H or H-Shield base insulation coverage) coverage) NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for F1.1654-1127 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 59 of 94 NNEMO etc. TABLE3A: STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System Deck MDP No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Min. 1.5-inch Polytherm, ACFoam II, Structural Polytherm G, ACFoam III, ENRGY 3, (Optional) additional layers(s) of C-49 concrete PG100 Polytherm H, H-Shield, H-Shield CG or Hot asphalt base insulation Hot asphalt APP-SA-H (Optional)APP-TA APP-TA 480.0 Multi -Max FA3 HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY TO INSULATION: Structural (Optiona (Optional) additional layers(s) of C-50 concrete 1) PG100 Min. 1.5-inch H-Shield or Multi -Max FA3 D-IS base insulation D-IS SBS-SA-H (Optional) SBS-TA SBS-TA 67.5 C-51 Structural None Min. 1.5-inch Polytherm H, H-Shield D-IS (Optional) additional layers(s) of D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 concrete base insulation Structural (Optiona Min. 1.5-inch Polytherm, ACFoam II or (Optional) additional layers(s) of C 52 concrete 1) PG100 ENRGY 3 D-IS base insulation D-IS SBS SA-H (Optional) SBS TA SBS TA 135.0 Structural (Optional) additional Iayers(s) of C-53 concrete None Min. 1.5-inch Polytherm, ACFoam II OB500 base insulation OB500 SBS-SA-H (Optional) SBS-TA 56S-TA 122.5 Structural (Optional) additional layers(s) of C-54 concrete None Min. 1.5-inch ENRGY 3 OB500 base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA 127.5 Structural (Optional) additional layers(s) of C-55 None Min. 1.5-inch Polytherm H or H-Shield OB500 OB500 SBS-SA-H (Optional) SBS-TA SBS-TA 150.0 concrete base insulation Min. 1.5-inch Polytherm, ACFoam II, Structural M-OSFA or (Optional) additional layers(s) of M-OSFA or C-56 concrete None Polytherm G, ACFoam III, Polytherm H, H- M-PG1 base insulation M-PG1 SBS-SA-H (Optional) SBS-TA SBS-TA -122.5 Shield Structural Min. 1.5-inch Polytherm, ACFoam II, (Optional) additional layers(s) of C-57 concrete None ENRGY 3, H-Shield or Multi -Max FA3 M-OSFA base insulation M-OSFA 56S-SA-H (Optional) SBS-TA SBS-TA 232.5 Structural Min. 1.5-inch Polytherm, ACFoam II, (Optional) additional layers(s) of C-58 concrete None Polytherm H, H-Shield CR-20 base insulation CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA 122.5 Structural None Min. 2-inch Polytherm, ACFoam II, OB Classic (Optional) OB Classic C-59 (full- additional layers(s) of (full- SBS-SA-H (Optional) SBS-TA SBS-TA -270.0 concrete Polytherm H or H-Shield base insulation coverage) coverage) Min. 1.5-inch Polytherm, ACFoam II, Structural Polytherm G, ACFoam III, ENRGY 3, (Optional) additional layers(s) of C-60 concrete PG100 Polytherm H, H-Shield, H-Shield CG or Hot asphalt base insulation Hot asphalt SBS-SA-H (Optional) SBS-TA SBS-TA 480.0 Multi -Max FA3 SELF -ADHERING BASE PLY TO COVERBOARD: NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for F1.1654-1127 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 60 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) primer Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Min. 0.25-inch DensDeck Prime Structural (Optional) SBS-SA, SBS-SA, APP-SA, C-61 None Min. 1.5-inch Multi -Max FA3 D-IS or SECUROCK Gypsum -Fiber Roof D-IS SBS-SA -67.5 concrete Board SBS-TA, APP-TA SBS-TA, APP-TA Min. 1.5-inch, min. 2.0 pcf Insulfoam, Structural C-62 None Polytherm, ACFoam II, ENRGY 3, Polytherm D-IS Min. 0.25-inch DensDeck Prime D-IS SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 concrete H or H-Shield Structural Min. 0.25-inch DensDeck, (Optional) SIBS -TA, C-63 None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS D-IS SBS-SA SBS-TA, APP-TA -120.0 concrete DensDeck Prime APP-TA (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch DensDeck Prime Structural (Optional) SBS-TA, C-64 None ACFoam II, Polytherm G, ACFoam III, D-IS optionally primed with D-IS SBS-SA SBS-TA, APP-TA -282.5 concrete Polytherm H, H-Shield POLYBRITE 745 or WB3000 APP-TA (Optional) Min. 1.5-inch Polytherm, Structural Min. 0.25-inch DEXcell FA Glass (Optional) SBS-TA, C-65 None ACFoam II, Polytherm G, ACFoam III, D-IS D-IS SBS-SA SBS-TA, APP-TA -322.5 concrete Polytherm H, H-Shield Mat Roof Board APP TA Min. 0.25-inch SECUROCK (Optional) Min. 1.5-inch Polytherm, Structural Gypsum -Fiber Roof Board (Optional) SBS-SA, SBS-SA, APP-SA, C-66 None ACFoam II, Polytherm G, ACFoam III, D-IS D-IS SBS-SA 322.5 concrete optionally primed with SBS-TA, APP-TA SBS-TA, APP-TA Polytherm H, H-Shield POLYBRITE 745 or WB3000 Structural Min. 1.5-inch Polytherm, ACFoam II, ENRGY C-67 None OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 concrete 3, H-Shield or ISO 95+GL Structural Min. 0.25-inch DensDeck, (Optional) SBS-TA, C-68 None Min. 1.5-inch ENRGY 3 OB500 OB500 SBS-SA SBS-TA, APP-TA -127.5 concrete DensDeck Prime APP-TA Structural Min. 1.5-inch Polytherm, ACFoam II, H Min. 0.25-inch DensDeck, (Optional) SBS-TA, C-69 concrete None Shield or ISO 95+GL OB500 DensDeck Prime OB500 SBS-SA APP TA 565-TA, APP-TA 150.0 (Optional) Min. 1.5-inch Polytherm, Structural (Optional) SBS-TA, C-70 None ACFoam II, Polytherm G, ACFoam III, OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA SBS-TA, APP-TA -282.5 concrete Polytherm H, H-Shield APP TA (Optional) Min. 1.5-inch Polytherm, Structural Min. 0.25-inch DEXcell FA Glass (Optional) SBS-TA, C-71 None ACFoam II, Polytherm G, ACFoam III, OB500 OB500 SBS-SA SBS-TA, APP-TA -322.5 concrete Polytherm H, H-Shield Mat Roof Board APP-TA Min. 0.25-inch SECUROCK (Optional) Min. 1.5-inch Polytherm, Structural Gypsum -Fiber Roof Board (Optional) SBS-SA, SBS-SA, APP-SA, C 72 None ACFoam II, Polytherm G, ACFoam III, OB500 OB500 SBS SA 322.5 concrete optionally primed with SBS-TA, APP-TA SBS-TA, APP-TA Polytherm H, H-Shield POLYBRITE 745 or WB3000 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.3654-1127 Revision 25: 09/30/2020 Appendix 1, Page 61 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Structural Min. 1.5-inch Polytherm, ACFoam II, ENRGY C-73 None M-OSFA Min. 0.25-inch DensDeck Prime M-OSFA SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 concrete 3, H-Shield or Multi -Max FA3 Structural Min. 1.5-inch Polytherm, ACFoam II, ENRGY Min. 0.25-inch SECUROCK (Optional) SBS-SA, SBS-SA, APP-SA, C 74 concrete None 3, H-Shield or Multi -Max FA3 M-OSFA Gypsum -Fiber Roof Board M-OSFA SBS SA SBS-TA, APP-TA SBS-TA, APP-TA 232.5 (Optional) Min. 1.5-inch Polytherm, Structural M-OSFA or M-OSFA or (Optional) SBS-TA, C-75 None ACFoam II, Polytherm G, ACFoam III, Min. 0.25-inch DensDeck Prime SBS-SA SBS-TA, APP-TA -282.5 concrete Polytherm H, H-Shield M-PG1 M-PG1 APP TA (Optional) Min. 1.5-inch Polytherm, Structural M-OSFA or Min. 0.25-inch DEXcell FA Glass M-OSFA or (Optional) SBS-TA, C-76 None ACFoam II, Polytherm G, ACFoam III, SBS-SA SBS-TA, APP-TA -322.5 concrete Polytherm H, H-Shield M-PG1 Mat Roof Board M-PG1 APP TA Min. 0.25-inch SECUROCK (Optional) Min. 1.5-inch Polytherm, Structural M-OSFA or Gypsum -Fiber Roof Board M-OSFA or (Optional) SBS-SA, SBS-SA, APP-SA, C 77 None ACFoam II, Polytherm G, ACFoam III, SBS SA 322.5 concrete M-PG1 optionally primed with M-PG1 SBS-TA, APP-TA SBS-TA, APP-TA Polytherm H, H-Shield POLYBRITE 745 or W63000 Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 2-inch Polytherm, ACFoam II, min. 1.5-inch Structural Ultra -Max or Multi -Max FA-3, min. 1.3-inch Min. 0.25-inch DensDeck, C 78 None CR-20 CR-20 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -72.5 concrete Polytherm G, ACFoam III or min. 1.0-inch DensDeck Prime ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inch Ultra -Max or Multi -Max FA-3, min. Structural Min. inch DensDeck, (Optional) SBS-TA, C 79 None 1.3-inch Polytherm G, ACFoam III or min. CR-20 CR-20 SBS-SA SBS-TA, APP-TA -240.0 concrete 1.0-inch ISO 95+GL, Polytherm H, H-Shield, DensDeck Prime DensDDec APP-TA H-Shield CG or ENRGY 3 Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Structural min. 1.3-inch Polytherm G, ACFoam III or Min. 0.25-inch SECUROCK (Optional) SBS-SA, SBS-SA, APP-SA, C-80 concrete None min. 1.0-inch ISO 95+GL, Polytherm H, H- CR-20 Gypsum -Fiber Roof Board CR 20 SBS SA SBS-TA, APP-TA SBS-TA, APP-TA 240.0 Shield, H-Shield CG or ENRGY 3 (Optional) Min. 1.5-inch Polytherm, Structural (Optional) SBS-TA, C-81 None ACFoam II, Polytherm G, ACFoam III, CR-20 Min. 0.25-inch DensDeck Prime CR-20 SBS-SA SBS-TA, APP-TA -282.5 concrete Polytherm H, H-Shield APP-TA (Optional) Min. 1.5-inch Polytherm, Structural Min. 0.25-inch DEXcell FA Glass (Optional) SBS-TA, C 82 None ACFoam II, Polytherm G, ACFoam III, CR-20 CR-20 SBS-SA SBS-TA, APP-TA -322.5 concrete Polytherm H, H-Shield Mat Roof Board APP TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 62 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) M System Deck primer DP (Notes 6,7,8) No. (Note 1) Type Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply (psf) (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural Gypsum -Fiber Roof Board (Optional) SBS-SA, SBS-SA, APP-SA, C-83 concrete None ACFoam II, Polytherm G, ACFoam III, CR-20 optionally primed with CR-20 SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA 322.5 Polytherm H, H-Shield POLYBRITE 745 or WB3000 Structural Min. 2-inch Polytherm, ACFoam II, OB Classic Min. 0.25-inch SECUROCK OB Classic (Optional) SBS-SA, SBS-SA, APP-SA, concrete Polytherm H or H-Shield Gypsum -Fiber Roof Board SBS-TA, APP-TA SBS-TA, APP-TA C-84 None (full- (full- SBS-SA 350.0 coverage) coverage) Min. 1.5-inch Polytherm, ACFoam II, Structural Polytherm G, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK (Optional) SBS-SA, SBS-SA, APP-SA, C-85 concrete PG100 Polytherm H, H-Shield, H-Shield CG or Hot asphalt Gypsum -Fiber Roof Board Hot asphalt SBS SA SBS-TA, APP-TA SBS-TA, APP-TA 350.0 Multi -Max FA3 HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY TO COVERBOARD: C-86 Structural None Min. 1.5-inch Multi -Max FA3 D-IS Min. 0.25-inch SECUROCK D-IS APP-SA-H concrete Gypsum -Fiber Roof Board (Optional) APP-TA APP-TA 67.5 C 87 Structural None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch DensDeck, D-IS APP-SA-H (Optional) APP-TA APP-TA -120.0 concrete DensDeck Prime Min. 0.25-inch SECUROCK Structural (Optional) Min. 1.5-inch Polytherm, Gypsum -Fiber Roof Board C-88 None ACFoam II, Polytherm G, ACFoam III, D-IS optionally primed with D-IS APP-SA-H (Optional) APP-TA APP-TA -322.5 concrete Polytherm H, H-Shield POLYBRITE 745 or WB3000 or DEXcell FA Glass Mat Roof Board C 89 Structural None Min. 1.5-inch ENRGY 3 OB500 Min. 0.25-inch DensDeck, OB500 APP-SA-H (Optional) APP-TA APP-TA -127.5 concrete DensDeck Prime C-90 Structural None Min. 1.5-inch Polytherm, ACFoam II, H- OB500 Min. 0.25-inch DensDeck, OB500 APP-SA-H (Optional) APP-TA APP-TA -150.0 concrete Shield or ISO 95+GL DensDeck Prime Structural (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK C-91 None ACFoam II, Polytherm G, ACFoam III, OB500 Gypsum -Fiber Roof Board or OB500 APP-SA-H (Optional) APP-TA APP-TA -322.5 concrete Polytherm H, H-Shield DEXcell FA Glass Mat Roof Board (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural M-OSFA or M-OSFA or C-92 None ACFoam II, Polytherm G, ACFoam III, Gypsum -Fiber Roof Board or APP-SA-H (Optional) APP-TA APP-TA -322.5 concrete Polytherm H, H-Shield M-PG1 DEXcell FA Glass Mat Roof Board M PG1 NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for F1.1654-1127 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 63 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inch Ultra -Max or Multi -Max FA-3, min. Structural Min. 0.25-inch DensDeck, C-93 None 1.3-inch Polytherm G, ACFoam III or min. CR-20 CR-20 APP-SA-H (Optional) APP-TA APP-TA -240.0 concrete 1.0-inch ISO 95+GL, Polytherm H, H-Shield, DensDeck Prime H-Shield CG or ENRGY 3 Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Structural min. 1.3-inch Polytherm G, ACFoam III or Min. 0.25-inch SECUROCK C-94 None CR-20 CR-20 APP-SA-H (Optional) APP-TA APP-TA 240.0 concrete min. 1.0-inch ISO 95+GL, Polytherm H, H- Gypsum -Fiber Roof Board Shield, H-Shield CG or ENRGY 3 (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural C-95 None ACFoam II, Polytherm G, ACFoam III, CR-20 Gypsum -Fiber Roof Board or CR-20 APP-SA-H (Optional) APP-TA APP-TA -322.5 concrete Polytherm H, H-Shield DEXcell FA Glass Mat Roof Board OB Classic OB Classic Structural Min. 2-inch Polytherm, ACFoam II, Min. 0.25-inch SECUROCK C-96 None (full- (full- APP-SA-H (Optional) APP-TA APP-TA -350.0 concrete Polytherm H or H-Shield Gypsum -Fiber Roof Board coverage) coverage) Min. 1.5-inch Polytherm, ACFoam II, Structural Polytherm G, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK C 97 PG100 Hot asphalt Hot asphalt APP-SA-H (Optional) APP-TA APP-TA -350.0 concrete Polytherm H, H-Shield, H-Shield CG or Gypsum -Fiber Roof Board Multi -Max FA3 HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY TO COVERBOARD: Min. 0.25-inch DensDeck Prime C 98 Structural None Min. 1.5-inch Multi -Max FA3 DAS or SECUROCK Gypsum -Fiber Roof D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -67.5 concrete Board Structural Min. 0.25-inch DensDeck, C-99 None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -120.0 concrete DensDeck Prime Structural Min. 2-inch Polytherm, ACFoam II, ENRGY- Min. 0.25-inch SECUROCK C-100 None D-IS D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 concrete 3, Polytherm H or H-Shield Gypsum -Fiber Roof Board (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch DensDeck Prime Structural C-101 None ACFoam II, Polytherm G, ACFoam III, DAS optionally primed with D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 concrete Polytherm H, H-Shield POLYBRITE 745 or WB3000 Min. 0.25-inch SECUROCK (Optional) Min. 1.5-inch Polytherm, Gypsum -Fiber Roof Board Structural C-102 None ACFoam II, Polytherm G, ACFoam III, D-IS optionally primed with D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 concrete Polytherm H, H-Shield POLYBRITE 745 or WB3000 or DEXcell FA Glass Mat Roof Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 64 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) primer Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Structural Min. 0.25-inch DensDeck, C-103 None Min. 1.5-inch ENRGY 3 013500 OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 concrete DensDeck Prime Structural Min. 1.5-inch Polytherm, ACFoam II, H- Min. 0.25-inch DensDeck, C-104 None OB500 OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -150.0 concrete Shield or ISO 95+GL DensDeck Prime Structural Min. 2-inch Polytherm, ACFoam II, ENRGY- Min. 0.25-inch SECUROCK C-105 None OB500 OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 concrete 3, Polytherm H or H-Shield Gypsum -Fiber Roof Board (Optional) Min. 1.5-inch Polytherm, Structural C-106 None ACFoam II, Polytherm G, ACFoam III, OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 concrete Polytherm H, H-Shield (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural C-107 None ACFoam II, Polytherm G, ACFoam III, OB500 Gypsum -Fiber Roof Board or OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 concrete Polytherm H, H-Shield DEXcell FA Glass Mat Roof Board Structural Min. 1.5-inch Polytherm, ACFoam II, ENRGY Min. 0.25-inch SECUROCK C-108 None M-OSFA M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -232.5 concrete 3, H-Shield or Multi -Max FA3 Gypsum -Fiber Roof Board Structural Min. 2-inch Polytherm, ACFoam II, ENRGY- Min. 0.25-inch SECUROCK C-109 None M-OSFA M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 concrete 3, Polytherm H or H-Shield Gypsum -Fiber Roof Board (Optional) Min. 1.5-inch Polytherm, Structural M-OSFA or M-OSFA or C-110 None ACFoam II, Polytherm G, ACFoam III, Min. 0.25-inch DensDeck Prime SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 concrete Polytherm H, H-Shield M-PG1 M-PG1 (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural M-OSFA or M-OSFA or C-111 None ACFoam II, Polytherm G, ACFoam III, Gypsum -Fiber Roof Board or SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 concrete Polytherm H, H-Shield M-PG1 DEXcell FA Glass Mat Roof Board M PG1 Min. 1.5-inch, min. 2.0 pcf Insulfoam, Min. 1.5-inch Ultra -Max or Multi -Max FA-3, min. Structural Min. 0.25-inch DensDeck, C-112 None 1.3-inch Polytherm G, ACFoam III or min. CR-20 CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 concrete 1.0-inch ISO 95+GL, Polytherm H, H-Shield, DensDeck Prime H-Shield CG or ENRGY 3 Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Structural min. 1.3-inch Polytherm G, ACFoam III or Min. 0.25-inch SECUROCK C-113 None CR-20 CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA 240.0 concrete min. 1.0-inch ISO 95+GL, Polytherm H, H- Gypsum -Fiber Roof Board Shield, H-Shield CG or ENRGY 3 Structural Min. 2-inch Polytherm, ACFoam II, ENRGY- Min. 0.25-inch SECUROCK C-114 None CR-20 CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 concrete 3, Polytherm H or H-Shield Gypsum -Fiber Roof Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 65 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) (Optional) Min. 1.5-inch Polytherm, Structural C-115 None ACFoam II, Polytherm G, ACFoam III, CR-20 Min. 0.25-inch DensDeck Prime CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -282.5 concrete Polytherm H, H-Shield (Optional) Min. 1.5-inch Polytherm, Min. 0.25-inch SECUROCK Structural C-116 None ACFoam II, Polytherm G, ACFoam III, CR-20 Gypsum -Fiber Roof Board or CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -322.5 concrete Polytherm H, H-Shield DEXcell FA Glass Mat Roof Board OB Classic OB Classic Structural Min. 2-inch Polytherm, ACFoam ll, Min. -inch SECUROCK C-117 None (full - (full- SBS-SA-H (Optional) SBS-TA SBS-TA -350.0 concrete Polytherm H or H-Shield Gypsum -Fiber Roof Board coverage) coverage) Min. 1.5-inch Polytherm, ACFoam ll, Structural Polytherm G, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK C-118 PG100 Hot asphalt Hot asphalt SBS-SA-H (Optional) SBS-TA SBS-TA -350.0 concrete Polytherm H, H-Shield, H-Shield CG or Gypsum -Fiber Roof Board Multi -Max FA3 COLD -APPLIED BASE PLY: Min. 0.25-inch DensDeck Prime, Min. 1-inch Polytherm, ACFoam ll, Structural DEXcell FA Glass Mat Roof Board SBS-CA1, SBS- (Optional) SBS-CA1, SBS-CA1, SBS- C-119 None Polytherm G, ACFoam III, ENRGY 3, D-IS D-IS 120.0 concrete or SECUROCK Gypsum -Fiber Roof CA2 SBS-CA2 CA2, APP-CA1 Polytherm H or H-Shield Board Min. 1-inch Polytherm, ACFoam II, Min. 0.25-inch DensDeck Prime Structural SBS-CA1, SBS- C-120 None Polytherm G, ACFoam III, Polytherm H or D-IS or DEXcell FA Glass Mat Roof D-IS SBS-CA1 None -127.5 concrete H-Shield Board CA2, APP-CA1 Min. 1-inch Polytherm, ACFoam ll, Structural Min. 0.25-inch SECUROCK SBS-CA1, SBS- SBS-CA1, SBS- C-121 None Polytherm G, ACFoam III, Polytherm H or D-IS D-IS None -127.5 concrete Gypsum -Fiber Roof Board CA2 CA2, APP-CA1 H-Shield Min. 25-inch DensDeck Prime 0. Structural Min. 1-inch ENRGY 3, Polytherm H or H- SBS-CA1, SBS- SBS-CA1, SBS- C-122 None D-IS or SECUROCK Gypsum -Fiber Roof D-IS None -232.5 concrete Shield Board CA2 CA2 Min. 0.25-inch DensDeck, Min. 1-inch Polytherm, ACFoam II, DensDeck Prime, DEXcell FA Glass Polytherm G, ACFoam III, EnergyGuard Mat Roof Board, SECUROCK Structural Polyiso Insulation, ENRGY 3, Polytherm H, M-OSFA, Gypsum -Fiber Roof Board or M-OSFA or SBS-CA1, SBS- (Optional) SBS-CA1, SBS-CA1, SBS C-123 concrete None H-Shield ISO 95+ GL, Multi -Max FA3, M-PG1 SECUROCK Glass -Mat Roof Board, M-PG1 CA2 SBS-CA2 CA2, APP-CA1 120.0 RESISTA or UltraMax or min. 2-inch min. 7/16-inch DEXcell Cement DECKMATE Plus or DECKMATE Plus FA Roof Board or min. 0.5-inch SECUROCK Cement Roof Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 66 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply M DP (psf) (Notes 6,7,8) (Notes 6,7,8) Min. 1-inch Polytherm or ACFoam II, Min. 0.25-inch DensDeck Prime Polytherm G, ACFoam III, EnergyGuard or DEXcell FA Glass Mat Roof Structural Polyiso Insulation, ENRGY 3, Polytherm H, M-OSFA, Board, min. 7/16-inch DEXcell M-OSFA, SBS-CA1, SBS- C-124 concrete None H-Shield, ISO 95+ GL, Multi -Max FA3, M-PG1 Cement Roof Board or min. 0.5- M-PG1 SBS CA1 None CA2, APP-CA1 127.5 RESISTA or UltraMax or min. 2-inch inch SECUROCK Cement Roof DECKMATE Plus or DECKMATE Plus FA Board Min. 1-inch Polytherm or ACFoam Il, Polytherm G, ACFoam III, EnergyGuard Structural Polyiso Insulation, ENRGY 3, Polytherm H, M-OSFA, Min. 0.25-inch SECUROCK M-OSFA, SBS-CA1, SBS SBS-CA1, SBS- C 125 concrete None H-Shield, ISO 95+ GL, Multi -Max FA3, M-PG1 Gypsum -Fiber Roof Board M-PG1 CA2 None CA2, APP-CA1 127.5 RESISTA or UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA Min. 0.25-inch DensDeck, Min. 1-inch Polytherm or ACFoam II, DensDeck Prime, DEXcell FA Glass Polytherm G, ACFoam III, EnergyGuard Mat Roof Board, SECUROCK Structural Polyiso Insulation, ENRGY 3, Polytherm H, M-OSFA, Gypsum -Fiber Roof Board or M-OSFA, SBS-CA1, SBS- SBS-CA1, SBS- C-126 concrete None H-Shield, ISO 95+ GL, Multi -Max FA3, M-PG1 SECUROCK Glass -Mat Roof Board, M-PG1 CA2 None CA2 232.5 RESISTA or UltraMax or min. 2-inch min. 7/16-inch DEXcell Cement DECKMATE Plus or DECKMATE Plus FA Roof Board or min. 0.5-inch SECUROCK Cement Roof Board Min. 0.25-inch DensDeck Prime, Min. 1-inch Polytherm, ACFoam II, Structural DEXcell FA Glass Mat Roof Board SBS-CA1, SBS- (Optional) SBS-CA1, SBS-CA1, SBS- C-127 None Polytherm G, ACFoam III, ENRGY 06500 OB500 120.0 concrete or SECUROCK Gypsum -Fiber Roof CA2 SBS-CA2 CA2, APP-CA1 ax FA3 Polytherm H, H-Shield or Multi -Mai - Board Min. 1-inch Polytherm, ACFoam II, Min. 0.25-inch DensDeck Prime Structural SBS-CA1, SBS- C-128 None Polytherm G, ACFoam III, ENRGY 3, OB500 or DEXcell FA Glass Mat Roof OB500 SBS-CA1 None -127.5 concrete Polytherm H, H-Shield or Multi -Max FA3 Board CA2, APP-CA1 Min. 1-inch Polytherm, ACFoam II, Structural Min. 0.25-inch SECUROCK SBS-CA1, SBS- SBS-CA1, SBS- C-129 None Polytherm G, ACFoam III, ENRGY 3, OB500 OB500 None -127.5 concrete Gypsum -Fiber Roof Board CA2 CA2, APP-CA1 Polytherm H, H-Shield or Multi -Max FA3 Min. 0.25-inch DensDeck Prime, Structural Min. 1-inch Polytherm, ACFoam II, ENRGY 3 DEXcell FA Glass Mat Roof Board SBS-CA1, SBS SBS-CA1, SBS- C 130 concrete None or Multi -Max FA3 OB500 or SECUROCK Gypsum -Fiber Roof OB500 CA2 None CA2 232.5 Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 67 of 94 NNEMO I etc. TABLE3A: STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck .. VAPOR BARRIER OPTIONS Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Note 1) Primer Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Min. 1-inch Polytherm, ACFoam II, Min. 0.25-inch DensDeck Prime Structural SBS-CAl, SBS- (Optional) SBS-CA1, SBS-CA1, SBS- C-131 None Polytherm G, ACFoam III, ENRGY 3, CR-20 or SECUROCK Gypsum -Fiber Roof CR-20 -120.0 concrete Polytherm H, H-Shield or Multi -Max FA3 Board CA2 SBS-CA2 CA2, APP-CA1 Min. 1-inch Polytherm, ACFoam ll, Min. 0.25-inch DensDeck Prime Structural SBS-CA1, SBS- C-132 None Polytherm G, ACFoam III, ENRGY 3, CR-20 or DEXcell FA Glass Mat Roof CR-20 SBS-CA1 None -127.5 concrete Polytherm H, H-Shield or Multi -Max FA3 Board CA2, APP-CA1 Min. 1-inch Polytherm, ACFoam II, Structural Min. 0.25-inch SECUROCK SBS-CA1, SBS- SBS-CA1, SBS- C-133 None Polytherm G, ACFoam III, ENRGY 3, CR-20 CR-20 None -127.5 concrete Gypsum -Fiber Roof Board CA2 CA2, APP-CA1 Polytherm H, H-Shield or Multi -Max FA3 Min. 0.25-inch DensDeck Prime Structural Min. 1-inch ENRGY 3, Polytherm H, H- SBS-CA1, SBS- SBS-CA1, SBS- C-134 None CR-20 or SECUROCK Gypsum -Fiber Roof CR-20 None -232.5 concrete Shield, Multi -Max FA3 CA2 CA2 Board AN&L- System Deck No. (Note 1) -A& Primer 7 CONCRETElu TABLE 313: STRUCTURAL SYSTEM TYPE F: NON -INSULATED, Base Ply • • OR REROOF (TEAR -OFF) BONDED BASE SHEET, BONDED ROOFCOVER Roof Cover (Note 15) Ply Cap Ply MDP (psf) ASPHALT- OR TORCH -APPLIED BASE PLY: C-135 Structural concrete PG100 (Optional) SBS-TA (Optional) SBS-TA SBS-TA -495.0 C-136 Structural concrete PG100 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP -AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA, APP-TA 622.5 SELF -ADHERING BASE PLY: C-137 Structural concrete PG100 SBS-SA (Optional) SBS-SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -315.0 HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: C-138 Structural concrete PG100 APP-SA-H (Optional) APP-TA APP-TA -315.0 HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: C-139 Structural concrete PG100 SBS-SA-H (Optional) SBS-TA SBS-TA -315.0 COLD -APPLIED BASE PLY: C-140 Structural concrete None SBS-CAI None SBS-CA1, SBS-CA2, APP-CA1 -105.0 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 68 of 94 NNEMO I etc. TABLE4A: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDEDROOF COVER Base Insulation Layer Coverboard Roof Cover (Note 15) System Deck Lightweight Concrete MDP No. (Note 1) (Note 14) Type Attach Type Attach gale Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) CELCORE(FL2037): ASPHALT OR TORCH APPLIED BASE PLY: Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch (Optional) BP - Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK BP -AA, SBS- AA, SBS-AA, SBS-AA, SBS- LWC-1 concrete Celcore Cellular Concrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR-20 Gypsum -Fiber Roof CR-20 AA APP-TA SBS-TA or APP- TA, APP-TA 222.5 Max FA3 or min. 2.0 pcf Insulfoam Board TA SELF -ADHERING BASE PLY: (Optional) Structural Min. 200 psi, min. 2-inch (Optional) SBS- SBS-SA, APP- LWC-2 Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Additional layers of CR-20 SBS-SA -222.5 concrete Celcore Cellular Concrete base insulation SA SA Min. 1.5-inch Polytherm, ACFoam II, (Optional) (Optional) SBS- SBS-SA, APP- Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ LWC-3 CR-20 Additional layers of CR-20 SBS-SA SA, SBS-TA, SA, SBS-TA, -222.5 concrete Celcore Cellular Concrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 base insulation APP-TA APP-TA Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch (Optional) SBS- SBS-SA, APP- Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK LWC-4 concrete Celcore Cellular Concrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR-20 Gypsum -Fiber Roof CR-20 SBS-SA SA, SBS-TA, SA, SBS-TA, 222.5 Max FA3 or min. 2.0 pcf Insulfoam Board APP-TA APP-TA HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 1.5-inch Polytherm, ACFoam II, (Optional) Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ (Optional) APP- LWC 5 CR-20 Additional layers of CR 20 APP-SA-H APP-TA 222.5 concrete Celcore Cellular Concrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- TA Max FA3 base insulation Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK (Optional) APP- LWC 6 concrete Celcore Cellular Concrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR-20 Gypsum -Fiber Roof CR 20 APP-SA-H TA APP TA 222.5 Max FA3 or min. 2.0 pcf Insulfoam Board HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 1.5-inch Polytherm, ACFoam II, (Optional) Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ (Optional) SBS- LWC-7 CR 20 Additional layers of CR-20 SBS SA H SBS-TA 222.5 concrete Celcore Cellular Concrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- TA Max FA3 base insulation Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 9S+ SECUROCK (Optional) SBS- LWC-8 concrete Celcore Cellular Concrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR-20 Gypsum -Fiber Roof CR-20 SBS-SA-H TA SBS-TA 222.5 Max FA3 or min. 2.0 pcf Insulfoam Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 69 of 94 NNEMO I etc. TABLE4A: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDEDROOF COVER Base Insulation Layer Coverboard Roof Cover (Note 15) System Deck Lightweight Concrete MDP No. (Note 1) (Note 14) Type Attach Type Attach gale Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) ELASTIZELL (FL4994): ASPHALT OR TORCH APPLIED BASE PLY: Min. 200 psi, min 2-inch Min. 0.25-inch (Optional) BP- Structural Range II Elastizell Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, SECUROCK BP -AA, SBS- AA, SBS-AA, SBS-AA, SBS LWC 9 concrete Lightweight Insulating ISO 95+ GL, Polytherm H or H-Shield OB500 Gypsum -Fiber Roof OB500 AA APP-TA SBS-TA or APP- TA, APP-TA 225.0 Concrete. Board TA Min. 200 psi, min 2-inch Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch (Optional) BP - Structural Range II Elastizell Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK BP -AA, SBS- AA, SBS-AA, SBS-AA, SBS- LWC 10 concrete Lightweight Insulating GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR 20 Gypsum -Fiber Roof CR-20 AA, APP-TA SBS-TA or APP- TA, APP-TA 180.0 Concrete. Max FA3 or min. 2.0 pcf Insulfoam Board TA SELF -ADHERING BASE PLY: Min. 200 psi, min 2-inch (Optional) Structural Range II Elastizell (Optional) SBS- SBS-SA, APP- LWC-11 Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Additional layers of OB500 SBS-SA -120.0 concrete Lightweight Insulating SA SA Concrete. base insulation Min. 200 psi, min 2-inch Min. 0.25-inch (Optional) SBS- SBS-SA, APP- Structural Range II Elastizell SECUROCK LWC-12 Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 OB500 SBS-SA SA, SBS-TA, SA, SBS-TA, 120.0 concrete Lightweight Insulating Gypsum -Fiber Roof Concrete. Board APP TA APP-TA Min. 200 psi, min 2-inch (Optional) (Optional) SBS- SBS-SA, APP- Structural Range II Elastizell Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, LWC-13 OB500 Additional layers of OB500 SBS-SA SA, SBS-TA, SA, SBS-TA, -225.0 concrete Lightweight Insulating ISO 95+ GL, Polytherm H or H-Shield Concrete. base insulation APP-TA APP-TA Min. 200 psi, min 2-inch Min. 0.25-inch (Optional) SBS- SBS-SA, APP- Structural Range II Elastizell Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, SECUROCK LWC-14 concrete Lightweight Insulating ISO 95+ GL, Polytherm H or H-Shield OB500 Gypsum -Fiber Roof OB500 SBS-SA SA, SBS-TA, SA, SBS-TA, 225.0 Concrete. Board APP-TA APP-TA Min. 200 psi, min 2-inch (Optional) Structural Range II Elastizell (Optional) SBS- SBS-SA, APP- LWC-15 Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Additional layers of CR-20 SBS-SA -180.0 concrete Lightweight Insulating SA SA Concrete. base insulation Min. 200 psi, min 2-inch Min. 1.5-inch Polytherm, ACFoam II, (Optional) (Optional) SBS- SBS-SA, APP- Structural Range II Elastizell Polytherm G, ACFoam III, ENRGY 3, ISO 95+ LWC-16 CR-20 Additional layers of CR-20 SBS-SA SA, SBS-TA, SA, SBS-TA, -180.0 concrete Lightweight Insulating GL, Polytherm H, H-Shield, H-Shield CG, Multi - Concrete. Max FA3 base insulation APP-TA APP-TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 70 of 94 NNEMO I etc. TABLE4A: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDEDROOF COVER Base Insulation Layer Coverboard RoofCover(Note 15) System Deck Lightweight Concrete Base Ply Ply MDP Cap Ply (psf) No. (Note 1) (Note 14) Type Attach Type Attach (Notes 6,7,8) (Notes 6,7,8) Min. 200 psi, min 2-inch Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch (Optional) SBS , APP- Structural Range II Elastizell Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK LWC 17 concrete Lightweight Insulating GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR 20 Gypsum -Fiber Roof CR-20 SBS-SA SA, SBS-TA, SA, SBS-TA, SA, SBS-TA, 180.0 Concrete. Max FA3 or min. 2.0 pcf Insulfoam Board APP-TA APP-TA HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 200 psi, min 2-inch Min. 0.25-inch Structural Range II Elastizell SECUROCK (Optional) APP- LWC-18 Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 OB500 APP-SA-H APP-TA 120.0 concrete Lightweight Insulating Gypsum -Fiber Roof TA Concrete. Board Min. 200 psi, min 2-inch (Optional) Structural Range II Elastizell Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) APP- LWC-19 OB500 Additional layers of OB500 APP-SA-H APP-TA 225.0 concrete Lightweight Insulating ISO 95+GL, Polytherm H or H-Shield TA Concrete. base insulation Min. 200 psi, min 2-inch Min. 0.25-inch Structural Range II Elastizell Min. 1.5-inch Polytherm, ACFoam Il, ENRGY 3, SECUROCK (Optional) APP- LWC-20 concrete Lightweight Insulating ISO 95+GL, Polytherm H or H-Shield OB500 Gypsum -Fiber Roof OB500 APP-SA-H TA APP-TA -225.0 Concrete. Board Min. 200 psi, min 2-inch Min. 1.5-inch Polytherm, ACFoam Il, (Optional) Structural Range II Elastizell Polytherm G, ACFoam III, ENRGY 3, ISO 95+ (Optional) APP LWC-21 CR-20 Additional layers of CR-20 APP-SA-H APP-TA 180.0 concrete Lightweight Insulating GL, Polytherm H, H-Shield, H-Shield CG, Multi- TA Concrete. Max FA3 base insulation Min. 200 psi, min 2-inch Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch Structural Range II Elastizell Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK (Optional) APP- LWC-22 concrete Lightweight Insulating GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR 20 Gypsum -Fiber Roof CR 20 APP-SA-H TA APP-TA 180.0 Concrete. Max FA3 or min. 2.0 pcf Insulfoam Board HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 200 psi, min 2-inch Min. 0.25-inch Structural Range II Elastizell SECUROCK (Optional) SBS- LWC-23 concrete Lightweight Insulating Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Gypsum -Fiber Roof OB500 SBS-SA-H TA SBS-TA -120.0 Concrete. Board Min. 200 psi, min 2-inch (Optional) Structural Range II Elastizell Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) SBS- LWC-24 OB500 Additional layers of OB500 SBS-SA-H SBS-TA -225.0 concrete Lightweight Insulating ISO 95+GL, Polytherm H or H-Shield TA Concrete. base insulation NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 71 of 94 NNEMO I etc. TABLE4A: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDEDROOF COVER Base Insulation Layer Coverboard Roof Cover (Note 15) System Deck Lightweight Concrete MDP Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) (Note 14) (psf) (Notes 6,7,8) (Notes 6,7,8) Min. 200 psi, min 2-inch Min. 0.25-inch Structural Range II Elastizell Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, SECUROCK (Optional) SBS LWC-25 concrete Lightweight Insulating ISO 95+ GL, Polytherm H or H-Shield OB500 Gypsum -Fiber Roof OB500 SBS SA-H TA SBS-TA 225.0 Concrete. Board Min. 200 psi, min 2-inch Min. 1.5-inch Polytherm, ACFoam II, (Optional) Structural Range II Elastizell Polytherm G, ACFoam III, ENRGY 3, ISO 95+ (Optional) SBS- LWC 26 CR-20 Additional layers of CR-20 SBS SA-H SBS-TA 180.0 concrete Lightweight Insulating GL, Polytherm H, H-Shield, H-Shield CG, Multi- TA Concrete. Max FA3 base insulation Min. 200 psi, min 2-inch Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch Structural Range II Elastizell Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK (Optional) SBS- LWC-27 concrete Lightweight Insulating GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR-20 Gypsum -Fiber Roof CR-20 SBS-SA-H TA SBS-TA 180.0 Concrete. Max FA3 or min. 2.0 pcf Insulfoam Board MEARLCRETE(FL13492): ASPHALT OR TORCH APPLIED BASE PLY: Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch (Optional) BP - Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK BP -AA, SBS- AA, SBS-AA, SBS-AA, SBS- LWC-28 concrete Mearlcrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR-20 Gypsum -Fiber Roof CR-20 AA, APP-TA SBS-TA or APP- TA, APP-TA 222.5 Max FA3 or min. 2.0 pcf Insulfoam Board TA SELF -ADHERING BASE PLY: (Optional) Structural Min. 200 psi, min. 2-inch (Optional) SBS- SBS-SA, APP- LWC-29 Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Additional layers of CR-20 SBS-SA 222.5 concrete Mearlcrete base insulation SA SA Min. 1.5-inch Polytherm, ACFoam II, (Optional) (Optional) SBS- SBS-SA, APP Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ LWC-30 CR-20 Additional layers of CR-20 SBS-SA SA, SBS-TA, SA, SBS-TA, -222.5 concrete Mearlcrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- Max FA3 base insulation APP-TA APP-TA Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch (Optional) SBS- SBS-SA, APP- Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK LWC 31 CR-20 CR 20 SBS SA SA, SBS TA, SA, SBS TA, 222.5 concrete Mearlcrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- Gypsum -Fiber Roof Max FA3 or min. 2.0 pcf Insulfoam Board APP-TA APP-TA HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 1.5-inch Polytherm, ACFoam II, (Optional) Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ (Optional) APP- LWC-32 CR-20 Additional layers of CR-20 APP SA H APP TA 222.5 concrete Mearlcrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- TA Max FA3 base insulation NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 72 of 94 NNEMO I etc. TABLE4A: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDEDROOF COVER Base Insulation Layer Coverboard Roof Cover (Note 15) System Deck Lightweight Concrete Base Ply Ply MDP Cap Ply (psf) No. (Note 1) (Note 14) Type Attach Type Attach (Notes 6,7,8) (Notes 6,7,8) Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK (Optional) APP- LWC 33 concrete Mearlcrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR 20 Gypsum -Fiber Roof CR-20 APP-SA-H TA APP-TA 222.5 Max FA3 or min. 2.0 pcf Insulfoam Board HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 1.5-inch Polytherm, ACFoam II, (Optional) Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ (Optional) SBS- LWC-34 CR-20 Additional layers of CR-20 SBS SA-H SBS-TA 222.5 concrete Mearlcrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- TA Max FA3 base insulation Min. 1.5-inch Polytherm, ACFoam II, Min. 0.25-inch Structural Min. 200 psi, min. 2-inch Polytherm G, ACFoam III, ENRGY 3, ISO 95+ SECUROCK (Optional) SBS- LWC-35 concrete Mearlcrete GL, Polytherm H, H-Shield, H-Shield CG, Multi- CR 20 Gypsum -Fiber Roof CR-20 SBS-SA-H TA SBS-TA 222.5 Max FA3 or min. 2.0 pcf Insulfoam Board TABLE413: LIGHTWEIGHT CONCRETE DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System Deck Lightweight Concrete MDP Attach Attach No. (Note 1) (Note 14) Type Fasten Attach yP yP Type (Notes Type ( Notes Base PI y PI y Ca PI p y (psf ) (Note 11) 6,7,8) 6,7,8) (Optional) Min. Min. 1.5-inch Thermaroof Min. 22 7-inch o.c. at Composite, Polytherm (Optional if ga., Type Min. 300 psi, min. 2- min. 4-inch lap 1.5-inch Composite, or min. 0.5- (Optional if using AA B, vented inch Celcore Cellular GAFGLAS OMG CR and 7-inch o.c. Polytherm, inch Structodek High using AA Base) BP SBS-AA, LWC-36 steel at Concrete, Elastizell #75 or BSF at two, equally ACFoam II, HA Density Fiberboard Roof HA Ply) BP -AA, AA, SBS-AA, SBS-TA, -45.0 Lightweight Insulating Elastovent Polytherm H APP-TA max. 5 ft Concrete or Mearlcrete spaced center Shield, Multi -Max t Insulation or min. 0.75- SBS-AA SBS-TA or spans rows FA3 or Polytherm inch Fesco Board APP-TA (homogeneous) Min. 22 7-inch o.c. at Min. 1.5-inch ga., Type Min. 300 psi, min. 2- min. 4-inch lap Polytherm, (Optional) SBS-SA, B, vented inch Celcore Cellular GAFGLAS OMG CR and 7-inch o.c. ACFoam II, SBS-SA, APP-SA, LWC-37 Concrete, Elastizell #75 or HA None N/A SBS-SA -45.0 steel at Lightweight Insulating Elastovent BSF at two, equally Polytherm H, H- SBS-TA, SBS-TA, max. 5 ft Concrete or Mearlcrete spaced center Shield, Multi -Max APP-TA APP-TA spans rows FA3 or Polytherm NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 73 of 94 NNEMO I etc. TABLE413: LIGHTWEIGHT CONCRETE DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System Deck Lightweight Concrete MDP Attach Attach No. (Note 1) (Note 14) T Fasten Attach yPe T yPe (Notes Type (Notes Base Ply Ply Cap Ply (psf) (Note 11) 6,7,8) 6,7,8) Min. 22 7-inch o.c. at Min. 1.5-inch ga., Type Min. 300 psi, min. 2- min. 4-inch lap Polytherm, inch Celcore Cellular GAFGLAS B, vented OMG CR and 7-inch o.c. ACFoam II, (Optional) LWC-38 Concrete, Elastizell #75 or HA None N/A APP-SA-H APP-TA -45.0 steel at BSF at two, equally Polytherm H, H- APP-TA Lightweight Insulating Elastovent max. 5 ft spaced center Shield, Multi -Max spans Concrete or Mearlcrete rows FA3 or Polytherm Min. 22 7-inch o.c. at Min. 1.5-inch ga., Type Min. 300 psi, min. 2- min. 4-inch lap Polytherm, inch Celcore Cellular GAFGLAS B, vented OMG CR and 7-inch o.c. ACFoam II, (Optional) LWC-39 Concrete, Elastizell #75 or HA None N/A SBS-SA-H SBS-TA -45.0 steel at BSF at two, equally Polytherm H, H- SBS-TA Lightweight Insulating Elastovent max. 5 ft spaced center Shield, Multi -Max spans Concrete or Mearlcrete rows FA3 or Polytherm CONCRETETABLE4C: LIGHTWEIGHT •ECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) ATTACHEDSYSTEM TYPE E-2: MECHANICALLY BASE SHEET, BONDED ROOF COVER System Base Sheet (Note A below) Roof Cover (Note 15) MDP Deck (Note 1) Lightweight Concrete (Note 14) No. Type Fasten (Note 11) Attach Base Ply I Cap Ply (psf) PRE-EXISTENT CELLULAR LWC: Min. 300 psi, min. 2-inch thick pre-existent Min. 22 ga., type B steel at cellular lightweight concrete. Note: To 7-inch o.c. at a min. 3-inch lap and 7-inch o.c. (Optional) LWC-40 max 5 ft spans or structural qualify the LWIC under this assembly, an a B3 or B11 OMG CR BPF at two, equally spaced, staggered rows in the BP -AA, SB SBS-AA, APP- -45.0 concrete OMG CR BPF shall achieve average field of the sheet SBS-AA TA withdrawal of 53 lbf when tested per TAS 105 or ANSI/SPRI FX-1 CELCORE(FL2037): ASPHALT OR TORCH APPLIED BASE PLY: Min. 0.0179-inch Tensilform S- 8-inch o.c. at a min. 3-inch lap and 16-inch LWC 41 75 or min. 0.0205-inch Min. 200 psi, min. 2-inch thick Celcore 61, B2, B3, 67 or Trufast FM-90 or o.c. at two, equally spaced, staggered rows in BP -AA, SBS-AA 37.5 Tensilform 75 at max. 5 ft Cellular Concrete B11 OMG CR BPF SBS-AA spans or structural concrete the field of the sheet Min. 22 ga., type B steel at 7-inch o.c. at a min. 3-inch lap and 7-inch o.c. LWC-42 max 5 ft spans or structural Min. 200 psi, min. 2-inch thick Celcore Bl through B11 Trufast FM-90 or at two, equally spaced, staggered rows in the BP AA SBS-AA -45.0 concrete Cellular Concrete OMG CR BPF field of the sheet SBS AA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 74 of 94 NNEMO I etc. TABLE4C: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) BONDEDSYSTEMTYPEE-2: MECHANICALLY ATTACHED BASE SHEET, ROOF System Base Sheet (Note A below) Roof Cover (Note 15) MDP Deck (Note 1) Lightweight Concrete (Note 14) Base Ply Cap Ply No. Type Fasten (Note 11) Attach (psf) Min. 26 ga., type HF steel at Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, B4, 9-inch o.c. at a min. 3-inch lap and 9-inch o.c. LWC-43 max 5 ft spans or structural Cellular Concrete with Celcore HS B7, B8, B10 or OMG CR BPF at two, equally spaced, staggered rows in the BP AA SBS-AA -45.0 concrete Rheology Modifying Admixture B11 field of the sheet SBS AA Min. 22 ga., type B steel at Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, 134, 7-inch o.c. at a min. 3-inch lap and 14-inch LWC-44 max 6 ft spans or structural Cellular Concrete with Celcore HS B7, B8, B10 or OMG CR BPF o.c. at two, equally spaced, staggered rows inSBS-AA BP -AA, -45.0 concrete Rheology Modifying Admixture B11 the field of the sheet SBS-AA Min. 22 ga., type B steel at Min. 225 psi, min. 2-inch thick Celcore MF B1, B2, B3, B4, 9-inch o.c. at a min. 3-inch lap and 9-inch o.c. LWC-45 max 6 ft spans or structural Cellular Concrete with Celcore HS B7, B8, B10 or OMG CR BPF at two, equally spaced, staggered rows in theSBS-AA BP -AA, -45.0 concrete Rheology Modifying Admixture B11 field of the sheet SBS AA Min. 22 ga., type B steel at Min. 225 psi, min. 2-inch thick Celcore MF 9-inch o.c. at a min. 4-inch lap and 18-inch BP -AA, SBS-AA, SBS- LWC-46 max 5 ft spans or structural Cellular Concrete with Celcore HS B1, B2 or B11 Trufast Twin Loc- o.c. at two, equally spaced, staggered rows in SBS AA' TA, or APP- -45.0 concrete Rheology Modifying Admixture Nail the field of the sheet SBS-TA or TA APP-TA Min. 22 ga., type B steel at Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- Trufast Twin Loc- 9-inch o.c. at a min. 4-inch lap and 18-inch SBS-TA or SBS-TA or LWC-47 max 5 ft spans or structural Cellular Concrete with Celcore HS film top surface) Nail o.c. at two, equally spaced, staggered rows in APP TA APP TA -45.0 concrete Rheology Modifying Admixture the field of the sheet Min. 22 ga., type B steel at Min. 300 psi, min. 2-inch thick Celcore MF 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. BP AA, SBS-AA, SBS- LWC-48 max 5 ft spans or structural Cellular Concrete with Celcore HS B2 or B11 Trufast FM-90 at three equally spaced, staggered center SBS AA' TA, or APP- -60.0 concrete Rheology Modifying Admixture rows SBS-TA or TA APP-TA Min. 22 ga., type B steel at Min. 300 psi, min. 2-inch thick Celcore MF B2 (faith poly- 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. SBS-TA or SBS-TA or LWC-49 max 5 ft spans or structural Cellular Concrete with Celcore HS film top surface) Trufast FM-90 at three equally spaced, staggered center APP-TA APP-TA -60.0 concrete Rheology Modifying Admixture rows Min. 22 ga., type B steel at 7-inch o.c. at a min. 3-inch lap and 7-inch o.c. BP AA, Min. 300 psi, min. 2-inch thick Celcore Trufast FM-90 or SBS-AA, SBS-AA, APP- LWC-50 max 5 ft spans or structural Cellular Concrete 61 through B11 OMG CR BPF at two, equally spaced, staggered rows in the SBS-TA, TA _75.0 concrete field of the sheet APP-TA (Optional) Min. 22 ga., type B steel at Min. 300 psi, min. 2-inch thick Celcore MF 10-inch o.c. at a min. 4-inch lap and 10-inch BP -AA, LWC-51 max 5 ft spans or structural Cellular Concrete with Celcore HS Elastobase P Trufast FM-290 o.c. at three equally spaced, staggered center SBS-AA, SBS-AA, SBS- -90.0 concrete Rheology Modifying Admixture rows SBS-TA or TA, APP-TA APP-TA SELF -ADHERING BASE PLY: Min. 22 ga., type B steel at Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- Trufast Twin Loc- 9-inch o.c. at a min. 4-inch lap and 18-inch SBS-SA, APP- LWC-52 max 5 ft spans or structural Cellular Concrete with Celcore HS o.c. at two, equally spaced, staggered rows in SBS-SA SA, SBS-TA -45.0 concrete Rheology Modifying Admixture film top surface) Nail the field of the sheet or APP-TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 75 of 94 NNEMO I etc. TABLE4C: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) BONDEDSYSTEMTYPEE-2: MECHANICALLY ATTACHED BASE SHEET, ROOF System Base Sheet (Note A below) Roof Cover (Note 15) MDP Deck (Note 1) Lightweight Concrete (Note 14) No. Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) Min. 22 ga., type B steel at Min. 300 psi, min. 2-inch thick Celcore MF B2 (faith poly- 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. SBS-SA, APP- LWC-53 max 5 ft spans or structural Cellular Concrete with Celcore HS film top surface) Trufast FM-90 at three equally spaced, staggered center SBS-SA SA, SBS-TA -60.0 concrete Rheology Modifying Admixture rows or APP-TA HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 22 ga., type B steel at Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- Trufast Twin Loc- 9-inch o.c. at a min. 4-inch lap and 18-inch LWC-54 max 5 ft spans or structural Cellular Concrete with Celcore HS film top surface) Nail o.c. at two, equally spaced, staggered rows in APP-SA-H APP-TA -45.0 concrete Rheology Modifying Admixture the field of the sheet Min. 22 ga., type B steel at Min. 300 psi, min. 2-inch thick Celcore MF B2 (with poly- 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. LWC-55 max 5 ft spans or structural Cellular Concrete with Celcore HS film top surface) Trufast FM-90 at three equally spaced, staggered center APP-SA-H APP-TA -60.0 concrete Rheology Modifying Admixture rows HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 22 ga., type B steel at Min. 225 psi, min. 2-inch thick Celcore MF B2 (with poly- Trufast Twin Loc- 9-inch o.c. at a min. 4-inch lap and 18-inch LWC-56 max 5 ft spans or structural Cellular Concrete with Celcore HS film top surface) Nail o.c. at two, equally spaced, staggered rows in SBS-SA-H SBS-TA -45.0 concrete Rheology Modifying Admixture the field of the sheet Min. 22 ga., type B steel at Min. 300 psi, min. 2-inch thick Celcore MF B2 (with poly- 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. LWC-57 max 5 ft spans or structural Cellular Concrete with Celcore HS film top surface) Trufast FM-90 at three equally spaced, staggered center SBS-SA-H SBS-TA -60.0 concrete Rheology Modifying Admixture rows ELASTIZELL (FL4994): ASPHALT OR TORCH APPLIED BASE PLY: Min. 0.0179-inch Tensilform S BP -AA, 75 or min. 0.0205-inch Min. 200 psi, min. 2-inch thick Range II Trufast FM-90 or 7.5-inch o.c. at a min. 3-inch lap and 7.5-inch SBS-AA, SBS-AA, SBS- LWC-58 Tensilform 75 at max. 5 ft Elastizell Lightweight Insulating Concrete 61 through B11 OMG CR BPF o.c. at two, equally spaced, staggered rows in SBS-TA, TA, or APP- 30.0 the field of the sheet TA spans or structural concrete or APP-TA Min. 0.0179-inch Tensilform S- 75 or min. 0.0205-inch Min. 200 psi, min. 2-inch thick Range II B2 (with poly- Trufast FM-90 or 7.5-inch o.c. at a min. 3-inch lap and 7.5-inch SBS-TA or SBS-TA or LWC-59 Tensilform 75 at max. 5 ft Elastizell Lightweight Insulating Concrete film top surface) OMG CR BPF o.c. at two, equally spaced, staggered rows in APP-TA APP-TA 30.0 the field of the sheet spans or structural concrete Min. 22 ga., type B steel at 7-inch o.c. at a min. 3-inch lap and 7-inch o.c. BP -AA, SBS-AA, SBS- LWC 60 max 5 ft spans or structural Min. 200 psi, min. 2-inch thick Range II B1 through B11 Trufast FM-90 or two, equally spaced, staggered rows in the SBS-AA, TA, or APP- 45.0 Elastizell Lightweight Insulating Concrete OMG CR BPF SBS-TA, concrete fi field of the sheet or APP-TA TA Min. 22 ga., type B steel at Min. 200 psi, min. 2-inch thick Range II B2 (with poly- Trufast FM-90 or 7-inch o.c. at a min. 3-inch lap and 7-inch o.c. SBS-TA or SBS-TA or LWC-61 max 5 ft spans or structural Elastizell Lightweight Insulating Concrete film top surface) OMG CR BPF at two, equally spaced, staggered rows in the APP-TA APP-TA -45.0 concrete field of the sheet NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 76 of 94 NNEMO I etc. TABLE4C: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) BONDEDSYSTEMTYPEE-2: MECHANICALLY ATTACHED BASE SHEET, ROOF System Base Sheet (Note A below) Roof Cover (Note 15) MDP Deck (Note 1) Lightweight Concrete (Note 14) Base Ply Cap Ply No. Type Fasten (Note 11) Attach (psf) (Optional) Min. 22 ga., type B vented Min. 350 psi, min. 2-inch thick Elastizell Elastobase P 8-inch o.c. at a min. 4-inch lap and 8-inch o.c. BP -AA, SBS-AA, SBS- LWC-62 steel at max 5 ft spans or with Zell -Crete Fibers, supplemental (with poly film Trufast FM-290 at three, equally spaced, staggered rows in SBS-AA, TA, or APP- -52.5 structural concrete attached with Roofgrip #21 and 3-inch top surface) the field of the sheet SBS-TA, TA plates at 1 per 8 ft2 or APP-TA Min. 22 ga., type B steel at Min. 350 psi, min. 2-inch thick Elastizell Trufast Twin Loc- 6-inch o.c. at a min. 4-inch lap and 6-inch o.c. SBS-AA, SBS- LWC-63 max 5 ft spans or structural with Zell -Crete Fibers, supplemental B2 or B11 Nails (min. 1.8- at three, equally spaced, staggered rows in BP -AA or TA, SBS-SA, -60.0 concrete attached with Roofgrip #21 and 3-inch inch) the field of the sheet SBS-AA APP-TA or plates at 1 per 8 ft2 APP-SA Min. 22 ga., type B steel at Min. 350 psi, min. 2-inch thick Elastizell Trufast Twin Loc- 6-inch o.c. at a min. 4-inch lap and 6-inch o.c. with Zell -Crete Fibers, supplemental B2 (with poly- SBS-TA or SBS-TA or LWC-64 max 5 ft spans or structural attached with Roofgrip #21 and 3-inch film top surface) Nails (min. 1.8 at three, equally spaced, staggered rows in APP-TA APP-TA 60.0 concrete plates at 1 per 8 ft2 inch) the field of the sheet SELF -ADHERING BASE PLY: Min. 0.0179-inch Tensilform S- 7.5-inch o.c. at a min. 3-inch lap and 7.5-inch SBS-SA, APP- 75 or min. 0.0205-inch Min. 200 psi, min. 2-inch thick Range II B2 (with poly- Trufast FM-90 or LWC-65 o.c. at two, equally spaced, staggered rows in SBS-SA SA, SBS-TA -30.0 Tensilform 75 at max. 5 ft Elastizell Lightweight Insulating Concrete film top surface) OMG CR BPF the field of the sheet or APP-TA spans or structural concrete Min. 22 ga., type B steel at Min. 200 psi, min. 2-inch thick Range II B2 (with poly- Trufast FM-90 or 7-inch o.c. at a min. 3-inch lap and 7-inch o.c. SBS-SA, APP- LWC-66 max 5 ft spans or structural Elastizell Lightweight Insulating Concrete film top surface) OMG CR BPF at two, equally spaced, staggered rows in the SBS-SA SA, SBS-TA -45.0 concrete field of the sheet or APP-TA Min. 22 ga., type B steel at Min. 350 psi, min. 2-inch thick Elastizell Trufast Twin Loc- 6-inch o.c. at a min. 4-inch lap and 6-inch o.c. SBS-SA, APP- with Zell -Crete Fibers, supplemental B2 (with poly- LWC-67 max 5 ft spans or structural attached with Roofgrip #21 and 3-inch film top surface) Nails (min. 1.8- at three, equally spaced, staggered rows in SBS-SA SA, SBS-TA -60.0 concrete plates at 1 per 8 ft2 inch) the field of the sheet or APP-TA HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 22 ga., type B steel at Min. 200 psi, min. thick Range II B2 (with poly- Trufast FM-90 or 7-inch o.c. at a min. 3-inch lap and 7-inch o.c. LWC-68 max 5 ft spans or structural Elastizell Lightweight Insulating Concrete t Ins film top surface) OMG CR BPF at two, equally spaced, staggered rows in the APP-SA-H APP-TA -45.0 concrete field of the sheet Min. 22 ga., type B steel at Min. 350 psi, min. 2-inch thick Elastizell Trufast Twin Loc- 6-inch o.c. at a min. 4-inch lap and 6-inch o.c. LWC-69 max 5 ft spans or structural with Zell -Crete Fibers, supplemental 62 (with poly- Nails (min. 1.8- at three, equally spaced, staggered rows in APP-SA-H APP-TA -60.0 concrete attached with Roofgrip #21 and 3-inch film top surface) inch) the field of the sheet plates at 1 per 8 ft2 HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 22 ga., type B steel at Min. 200 psi, min. 2-inch thick Range II B2 (with poly- Trufast FM-90 or 7-inch o.c. at a min. 3-inch lap and 7-inch D.C. LWC-70 max 5 ft spans or structural Elastizell Lightweight Insulating Concrete film top surface) OMG CR BPF at two, equally spaced, staggered rows in the SBS-SA-H SBS-TA -45.0 concrete field of the sheet NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 77 of 94 NNEMO I etc. TABLE4C: LIGHTWEIGHT CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) BONDEDSYSTEMTYPEE-2: MECHANICALLY ATTACHED BASE SHEET, ROOF System Base Sheet (Note A below) Roof Cover (Note 15) MDP Deck (Note 1) Lightweight Concrete (Note 14) No. Type Fasten (Note 11) Attach Base Ply Cap Ply (psf) Min. 350 psi, min. 2-inch thick Elastizell Min. 22 ga., type B steel at Trufast Twin Loc- 6-inch o.c. at a min. 4-inch lap and 6-inch o.c. with Zell -Crete Fibers, supplemental B2 (with poly- LWC-71 max 5 ft spans or structural attached with Roofgrip #21 and 3-inch g p film top surface) Nails (min. 1.8- at three, equally spaced, staggered rows in SBS-SA-H SBS-TA -60.0 concrete plates at 1 per 8 ft2 inch) the field of the sheet MEARLCRETE(FL13492): ASPHALT OR TORCH APPLIED BASE PLY: Min. 24 ga., type B steel at Trufast FM-90 or 7.5-inch o.c. at a min. 3-inch lap and 10-inch Bp -AA, LWC-72 max 5 ft spans or structural Min. 200 psi, min. 2-inch thick Mearlcrete 61 through B11 o.c. at two, equally spaced, staggered rows in SBS-AA -30.0 concrete OMG CR BPF the field of the sheet SBS AA Min. 22 ga., type B steel at 7-inch o.c. at a min. 4-inch lap and 7-inch o.c. BP -AA, SBS-AA, SBS- LWC-73 max 5 ft spans or structural Min. 300 psi, min. 2-inch thick Mearlcrete Bl, B2, B3, B7 or Trufast FM-90 or at two, equally spaced, staggered rows in the SBS-AA, TA, or APP- -52.5 concrete gll OMG CR BPF field of the sheet SBS-TA, TA or APP-TA Min. 22 ga., type B steel at 7-inch o.c. at a min. 4-inch lap and 7-inch o.c. LWC-74 max 5 ft spans or structural Min. 300 psi, min. 2-inch thick Mearlcrete B2 (with poly- Trufast FM-90 or at two, equally spaced, staggered rows in the SBS-TA or SBS-TA or -52.5 film top surface) OMG CR BPF APP TA APP TA concrete lfield of the sheet SELF -ADHERING BASE PLY: Min. 22 ga., type B steel at poly- Trufast FM-90 or 7-inch o.c. at a min. 4-inch lap and 7-inch o.c. SBS-SA, APP- LWC-75 max 5 ft spans or structural Min. 300 psi, min. 2-inch thick Mearlcrete t topwith film top surface) OMG CR BPF at two, equally spaced, staggered rows in the SBS-SA SA, SBS-TA -52.5 concrete field of the sheet or APP-TA HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Min. 22 ga., type B steel at B2 (with poly- Trufast FM-90 or 7-inch o.c. at a min. 4-inch lap and 7-inch o.c. LWC-76 max 5 ft spans or structural Min. 300 psi, min. 2-inch thick Mearlcrete at two, equally spaced, staggered rows in the APP-SA-H APP-TA -52.5 concrete film top surface) OMG CR BPF field of the sheet HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Min. 22 ga., type B steel at B2 (with poly- Trufast FM-90 or 7-inch o.c. at a min. 4-inch lap and 7-inch O.C. LWC-77 max 5 ft spans or structural Min. 300 psi, min. 2-inch thick Mearlcrete film top surface) OMG CR BPF at two, equally spaced, staggered rows in the SBS-SA-H SBS-TA -52.5 concrete field of the sheet A. Base Sheets options in Table 4C are coded as follows: ➢ B1: Polyglass G2 Base; B2: Elastobase or Elastobase P; B3: GAFGLAS #75; B4: GAFGLAS Stratovent Noilable Venting Base Sheet; B5: GAFGLAS Ply 4; B6: GAFGLAS FlexPly 6; 37: JM Perma Ply No. 28; 138: JM Vensulation; B9: JM GlasPly IV, B10: JM GlasPly Premier, B11: Elostovent NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for FL1654-R27 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 78 of 94 NNEMO I etc. WOOD FIBER .REROOF (TEAR -OFF) STEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Notes 1 & 12) Type Attach FType Attach Base Ply Ply MDP Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) ASPHALT OR TORCH APPLIED BASE PLY: Min. DensDeck DensDeck, , Existing Min. 2.5-inch Min. 1.5-inch Polytherm, (Optional) BP -AA, D-IS or Prime, SECUROCK Gypsum -Fiber Roof SBS-AA, SBS- CWF-1 Tectum Plank or ACFoam II, ISO 95+GL, D-IS or OB500 BP -AA, SBS-AA SBS-AA, 565-TA or -45.0 OB500 Board or min. 0.5-inch Structodek High TA, APP-TA Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 APP TA Density Fiberboard Roof Insulation Existing Min. 2.5-inch Min. 1.5-inch Polytherm, Min. 0.25-inch DensDeck, DensDeck D-IS or SBS-TA or APP- (Optional) SBS-TA CWF-2 Tectum Plank or ACFoam II, ISO 95+GL, Prime, SECUROCK Gypsum -Fiber Roof D-IS or OB500 SBS-TA, APP-TA -45.0 Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 OB500 Board TA or APP-TA Min. DensDeck DensDeck, Existing Min. 2.5-inch Min. 1.5-inch Polytherm, , (Optional) BP -AA, Prime, SECUROCK Gypsum -Fiber Roof SBS-AA, SBS- CWF-3 Tectum Plank or ACFoam II, ISO 95+GL, CR-20 CR-20 BP -AA, SBS-AA SBS-AA, SBS-TA or -52.5 Board or min. 0.5-inch Structodek High TA APP TA Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 APP-TA Density Fiberboard Roof Insulation Existing Min. 2.5-inch Min. 1.5-inch Polytherm, Min. 0.25-inch DensDeck, DensDeck SBS-TA or APP- (Optional) SBS-TA CWF-4 Tectum Plank or ACFoam Il, ISO 95+GL, CR-20 Prime, SECUROCK Gypsum -Fiber Roof CR-20 SBS-TA, APP-TA -52.5 Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 Board TA or APP-TA SELF -ADHERING BASE PLY: Existing Min. 2.5-inch Min. 1.5-inch Polytherm, 0.25-inch DensDeck, DensDeck SBS-SA, APP- D-IMin. S or (Optional) SBS-SA, CWF-5 Tectum Plank or ACFoam II, ISO 95+GL, Prime, SECUROCK Gypsum -Fiber Roof D-IS or OB500 SBS-SA SA, SBS-TA, -45.0 Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 OB OB500 Board SBS-TA or APP-TA APP TA Existing Min. 2.5-inch Min. 1.5-inch Polytherm, Min. 0.25-inch DensDeck, DensDeck SBS-SA, APP- (Optional) SBS-SA, CWF-6 Tectum Plank or ACFoam II, ISO 95+GL, CR-20 Prime, SECUROCK Gypsum -Fiber Roof CR-20 SBS-SA SA, SBS-TA, -52.5 Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 Board 565-TA or APP-TA APP-TA HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Existing Min. 2.5-inch Min. 1.5-inch Polytherm, Min. 0.25-inch DensDeck, DensDeck CWF-7 Tectum Plank or ACFoam II, ISO 95+GL, or Prime, SECUROCK Gypsum -Fiber Roof D-IS or OB500 APP-SA-H (Optional) APP-TA APP-TA -45.0 Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 O B5 00 OB500 Board Existing Min. 2.5-inch Min. 1.5-inch Polytherm, Min. 0.25-inch DensDeck, DensDeck CWF-8 Tectum Plank or ACFoam II, ISO 95+GL, CR-20 Prime, SECUROCK Gypsum -Fiber Roof CR-20 APP-SA-H (Optional) APP-TA APP-TA -52.5 Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 Board HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Existing Min. 2.5-inch Min. 1.5-inch Polytherm, 0.25-inch DensDeck, DensDeck CWF-9 Tectum Plank or ACFoam II, ISO 95+GL, D-IMin. 5 or Prime, SECUROCK Gypsum -Fiber Roof D-IS or OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -45.0 Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 OB500 OB Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 79 of 94 NNEMO I etc. M WOOD FIBER .REROOF (TEAR -OFF) L__ STEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Notes 1 & 12) Type Attach Type Attach Base Ply Ply MDP Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Existing Min. 2.5-inch Min. 1.5-inch Polytherm, Min. 0.25-inch DensDeck, DensDeck WF-10 Tectum Plank or ACFoam II, ISO 95+GL, CR-20 Prime, SECUROCK Gypsum -Fiber Roof CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -52.5 Tectum LS Plank Polytherm H, H-Shield, ENRGY-3 Board TABLE513: CEIVIENTITIOUS WOOD FIBER DECKS — REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) Deck System Fasten Attach Attach M D P (psf) No. (Note 1) Type Attach Type Type Base Ply Ply Cap Ply (Note 11) (Notes 6,7,8) (Notes 6,7,8) ASPHALT OR TORCH APPLIED BASE PLY: Min. 1.5-inch Min. 0.25-inch DensDeck, Existing Min. Elastobase, Trufast 9-inch o.c. at min. 4-inch lap and 12-(Optional) Polytherm, ACFoam ll, DensDeck Prime, SECUROCK Gypsum -Fiber BP- 2.5-inch Elastobase P, Inuldek inch o.c. at two, Polytherm G, ACFoam Roof Board, Min. 0.75- BP -AA, AA, SBS-AA, SBS-AA, WF-11 Tectum Plank Elastovent or Loc-Nail III, ISO95+GL, Hot asphalt inch Fesco Board Hot asphalt SBS-TA, -30.0* or Tectum LS Polyglass G2 yg (reroof equally spaced, Polytherm H, H- (homogeneous) or min. SBS-AA 5B5-TA or APP- APP-TA Plank Base only) staggered center gg Shield, ENRGY 3 or 0.5-inch Structodek High TA rows Multi -Max FA3, Density Fiberboard Roof Insulation min.d o.c.-inch Min. 1.5-inch Existing Min. Elastobase, Trufast Polytherm, ACFoam II, Min. 0.25-inch 2.5-inch Elastobase P, Inuldek 4-inch 4 lap and 12- Polytherm G, ACFoam DensDeck, DensDeck SBS-TA WF-12 Tectum Plank Elastovent or Loc-Nail inch at two, III, ISO95+GL, Hot asphalt Prime, SECUROCK Hot asphalt or APP- (Optional) SBS- SBS-TA, -30.0* or Tectum LS Polyglass G2 (reroof equally spaced, equo.ally Polytherm H, H- Gypsum -Fiber Roof TA TA or APP-TA APP-TA Plank Base only) staggered center Shield, ENRGY 3 or Board rows Multi -Max FA3, Min. 1.5-inch Min. 0.25-inch DensDeck, 9-inch o.c. at min. DensDeck Prime, Existing Min. Elastobase, 4-inch lap and 18- Polytherm, ACFoam ll, SECUROCK Gypsum -Fiber YP (Optional) BP- 2.5-inch Elastobase P, Trufast inch o.c. at two, Polytherm G, ACFoam Roof Board, Min. 0.75- BP AA AA, SBS-AA, SBS-AA, CWF-13 Tectum Plank Elastovent or Twin equally spaced, III, IS095+GL, Hot asphalt inch Fesco Board Hot asphalt , SBS-AA SBS-TA or APP- SBS-TA, -45.0* or Tectum LS Polyglass G2 Loc-Nail Polytherm H, H- (homogeneous) or min. APP-TA Plank Base staggered center Shield, ENRGY 3 or 0.5-inch Structodek High TA rows Multi -Max FA3, Density Fiberboard Roof Insulation NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 80 of 94 NNEMO I etc. ...REROOF (TEAR -OFF) OR RECOVER SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System No. Note 1 ( ) Type yP Fasten Attach yP Type Attach Type Attach Base PI y PI y Ca PI P y MDP (psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Existing Min. Elastobase, 9-inch o.c. at min. Min. 1.5-inch Polytherm, Min. 0.25-inch 2.5-inch Elastobase P, Trufast 4-inch lap and 18- ACFoam II, Polytherm G, DensDeck, DensDeck SBS-TA WF-14 Tectum Plank Elastovent or Twin inch o.c. at two, ACFoam III, ISO95+GL, Hot asphalt Prime, SECUROCK Hot asphalt or APP- (Optional) SBS- SBS-TA, -45.0* equally spaced, Polytherm H, H-Shield, TA or APP-TA APP-TA or Tectum LS Polyglass G2 Loc-Nail staggered center ENRGY 3 or Multi -Max Gypsum -Fiber Roof TA Plank Base FA3, Board rows SELF -ADHERING BASE PLY: Existing Min. Elastobase, Trufast 9-inch O.C. at min. Min. 1.5-inch Polytherm, � Min. 0.25-inch 2.5-inch Elastobase P, Inuldek 4-inch lap and 12- ACFoam II, Polytherm G, DensDeck, DensDeck (Optional) SBS- SBS-TA, CWF-15 Tectum Plank Elastovent or Loc-Nail inch o.c. at two, ACFoam III, ISO95+GL, Hot asphalt Prime, SECUROCK Hot asphalt SBS-SA TA, SBS-SA or SBS-SA, -30.0* equally spaced, Polytherm H, H-Shield, APP-TA, or Tectum LS Polyglass G2 (reroof staggered center ENRGY 3 or Multi -Max Gypsum -Fiber Roof APP-TA APP-SA Plank Base only) FA3, Board rows Existing Min. Elastobase, 9-inch o.c. at min. Min. 1.5-inch Polytherm, � Min. 0.25-inch 2.5-inch Elastobase P, Trufast 4-inch lap and 18- ACFoam II, Polytherm G, DensDeck, DensDeck (Optional) SBS- SBS-TA, CWF-16 Tectum Plank Elastovent or Twin inch O.C. at two, ACFoam III, IS095+GL, Hot asphalt Prime, SECUROCK Hot asphalt SBS-SA TA, SBS-SA or SBS-SA, -45.0* equally spaced, Polytherm H, H-Shield, APP-TA, or Tectum LS Polyglass G2 Loc-Nail staggered center ENRGY 3 or Multi -Max Gypsum -Fiber Roof APP-TA APP-SA Plank Base FA3 Board rows HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Existing Min. Elastobase, Trufast 9-inch o.c. at min. Min. 1.5-inch Polytherm, Min. 0.25-inch 2.5-inch Elastobase P, Inuldek 4-inch lap and 12- ACFoam II, Polytherm G, DensDeck, DensDeck WF-17 Tectum Plank Elastovent or Loc-Nail inch o.c. at two, ACFoam III, ISO95+GL, Hot asphalt Prime, SECUROCK Hot asphalt APP-SA- (Optional) APP- APP-TA -30.0* equally spaced, Polytherm H, H-Shield, H TA or Tectum LS Polyglass G2 (reroof staggered center ENRGY 3 or Multi -Max Gypsum -Fiber Roof Plank Base only) FA3 Board rows Existing Min. Elastobase, 9-inch O.C. at min. Min. 1.5-inch Polytherm, `/t Min. 0.25-inch 2.5-inch Elastobase P, Trufast 4-inch lap and 18- ACFoam II, Polytherm G, DensDeck, DensDeck WF-18 Tectum Plank Elastovent or Twin inch o.c. at two, ACFoam III, ISO95+GL, Hot asphalt Prime, SECUROCK Hot asphalt APP-SA- (Optional) APP- APP-TA -45.0* equally spaced, Polytherm H, H-Shield, H TA or Tectum LS Polyglass G2 Loc-Nail staggered center ENRGY 3 or Multi -Max Gypsum -Fiber Roof Plank Base FA3, Board rows HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 81 of 94 NNEMO I etc. ...REROOF (TEAR -OFF) OR RECOVER SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) System Fasten Attach Attach MDP (psf) No. Note 1 ( ) yP Type Attach yP Type Type Base PI y PI y Ca PI P y (Note 11) (Notes 6,7,8) (Notes 6,7,8) Existing Min. Elastobase, Trufast 9-inch o.c. at min. Min. 1.5-inch Polytherm, Min. 0.25-inch 2.5-inch Elastobase P, Inuldek 4-inch lap and 12- ACFoam II, Polytherm G, DensDeck, DensDeck WF-19 Tectum Plank Elastovent or Loc-Nail inch o.c. at two, ACFoam III, ISO95+GL, Hot asphalt Prime, SECUROCK Hot asphalt SBS-SA- (Optional) SBS SBS-TA -30.0* equally spaced, Polytherm H, H-Shield, H TA or Tectum LS Polyglass G2 (reroof staggered center ENRGY 3 or Multi -Max Gypsum -Fiber Roof Plank Base only) FA3, Board rows Existing Min. Elastobase, 9-inch o.c. at min. Min. 1.5-inch Polytherm, Min. 0.25-inch 2.5-inch Elastobase P, Trufast 4-inch lap and 18- ACFoam II, Polytherm G, DensDeck, DensDeck WF-20 Tectum Plank Elastovent or Twin inch o.c. at two, ACFoam IIIIS095+GL , , Hot asphalt Prime, SECUROCK Hot asphalt SBS-SA- (Optional) SBS- SBS-TA -45.0* equally spaced, Polytherm H, H-Shield, H TA or Tectum LS Polyglass G2 Loc-Nail staggered center ENRGY 3 or Multi -Max Gypsum -Fiber Roof Plank Base FA3, Board rows NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 82 of 94 NNEMO I etc. TABLE SE: CEIVIENTITIOUS ...REROOF (TEAR -OFF) OR RECOVER SYSTEIVITYPEE-2: NON -INSULATED, MECHANICALLY ATTACHED BASE BONDED ROOF System Deck Base Sheet Roof Cover (Note 15) No. (Note 1) Type Fasten (Note 11) Attach Base Ply Cap Ply MDP (psf) Existing Min. 2.5 Elastobase, Elastobase P, Elastovent or Trufast Insuldek Loc-Nail 9-inch o.c. at min. 4-inch lap and 12-inch o.c. (Optional) BP -AA, SBS-AA, SBS-AA, CWF-23 inch Tectum Plank or Polyglass G2 Base (reroof only) at two, equally spaced, staggered center rows SBS-TA or APP-TA SBS-TA, -30.0* Tectum LS Plank APP TA Existing Min. 2.5- Elastobase, Elastobase P, Elastovent or 9-inch o.c. at min. 4-inch lap and 18-inch o.c. (Optional) BP -AA, SBS-AA, SBS-AA, CWF-24 inch Tectum Plank or Trufast Twin Loc-Nails SBS-TA, -45.0* Tectum LS Plank Polyglass G2 Base at two, equally spaced, staggered center rows SBS-TA or APP-TA APP-TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 83 of 94 NNEMO I etc. TABLE 6A: GYPSUM DECKS — REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) Deck System No. (Notes 1 & 12) Type Attach Type Attach gase Ply Ply MDP Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) ASPHALT -APPLIED BASE PLY: (Optional Existing, sound poured if using (Optional if using G-1 gypsum or gypsum Min. 0.25-inch DensDeck, DensDeck Prime or CR-20 None N/A AA Ply) AA Base) BP -AA, SBS-AA, SBS-TA, 245.0 SECUROCK Gypsum -Fiber Roof Board SBS-AA, SBS-TA APP-TA plank BP -AA, SBS-AA or APP-TA SELF -ADHERING BASE PLY: Existing, sound poured (Optional) SBS- Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, SBS-SA, APP-SA, G-2 gypsum or gypsum Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA 72.5 plank TA Existing, sound poured (Optional) SBS- G-3 gypsum or gypsum Min. 0.25-inch DensDeck Prime OB500 None N/A SBS-SA SA, SBS-TA, APP- SBS-SA, APP-SA, -72.5 plank TA SBS-TA, APP-TA Existing, sound poured (Optional) additional layers(s) of G-4 gypsum or gypsum Min. 1.5-inch min. 2.0 pcf, Insulfoam OB500 base insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA, APP-SA -112.5 plank Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) additional layers(s) of (Optional) SBS- SBS-SA, APP-SA, G-5 gypsum or gypsum Polytherm H or H-Shield OB500 base insulation OB500 SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA 112.5 plank TA Existing, sound poured (Optional) SBS- Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Min. 0.25-inch SECUROCK SBS-SA, APP-SA, G-6 gypsum or gypsum Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Gypsum -Fiber Roof Board OB500 SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA 112.5 plank TA Existing, sound poured Min. 0.25-inch SECUROCK Gypsum -Fiber Roof (Optional) SBS- SBS-SA, APP-SA, G-7 gypsum or gypsum Board OB500 None N/A SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA 112.5 plank TA Existing, sound poured (Optional) SBS- Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- SBS-SA, APP-SA, G-8 gypsum or gypsum Shield or Multi -Max FA3 M-OSFA Min. 0.25-inch DensDeck Prime M-OSFA SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA 72.5 plank TA Existing, sound poured (Optional) SBS- G-9 gypsum or gypsum Min. 0.25-inch DensDeck Prime M-OSFA None N/A SBS-SA SA, SBS-TA, APP- SBS-SA, APP-SA, -72.5 plank TA SBS-TA, APP-TA (Optional) additional layers(s) of Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H base insulation and/or min. (Optional) SBS SBS-SA, APP-SA, G-10 gypsum or gypsum Shield or Multi -Max FA3 M-OSFA 0.25-inch SECUROCK Gypsum M-OSFA SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA 202.5 plank Fiber Roof Board TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 84 of 94 NNEMO I etc. TABLE 6A: GYPSUM DECKS — REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Notes 1 & 12) Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Existing, sound poured (Optional) SBS- G-11 Min. 0.25-inch SECUROCK Gypsum -Fiber Roof M-OSFA None N/A SBS-SA SA, SBS-TA, APP- SBS-SA, APP-SA, gypsum or gypsum Board SBS-TA, APP-TA -202.5 plank TA Min. 1.5-inch, min. 2.0 pcf EPS insulation board, Existing, sound poured (Optional) SBS- Polytherm, ACFoam II, Polytherm G, ACFoam III, SBS-SA, APP-SA, G-12 gypsum or gypsum ENRGY 3, Polytherm H, H-Shield, H-Shield CG or CR-20 Min. 0.25-inch DensDeck Prime CR-20 SBS-SA SA, SBS-TA, APP SBS-TA, APP-TA 72.5 plank TA Multi -Max FA3 Existing, sound poured (Optional) SBS- G-13 gypsum or gypsum Min. 0.25-inch DensDeck Prime CR-20 None N/A SBS-SA SA, SBS-TA, APP- SBS-SA, APP-SA, 72.5 plank TA SBS-TA, APP-TA Existing, sound poured (Optional) additional layers of G-14 gypsum or gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 base insulation CR-20 SBS-SA (Optional) SBS-SA SBS-SA -240.0 plank Existing, sound poured (Optional) SBS- Min. 0.25-inch SECUROCK SBS-SA, APP-SA, G-15 gypsum or gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA 240.0 plank TA Existing, sound poured (Optional) SBS- Min. 0.25-inch SECUROCK Gypsum -Fiber Roof SBS-SA, APP-SA, G-16 gypsum or gypsum Board CR-20 None N/A SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA 240.0 plank TA (Optional) additional layers(s) ofbase Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, (Optional) SBS- base insulation and/or min. SBS-SA, APP-SA, G-17 gypsum or gypsum ACFoam III, ENRGY 3, Polytherm H, H-Shield, H- CR-20 inch SECUROCKand/or Gypsum- CR-20 SBS-SA SA, SBS-TA, APP- SBS-TA, APP-TA -257.5 plank Shield CG or Multi -Max FA3 TA Fiber Roof Board HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) additional layers(s) of (Optional) APP- G-18 gypsum or gypsum Polytherm H or H-Shield OB500 base insulation OB500 APP-SA-H TA APP-TA -112.5 plank Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Min. 0.25-inch SECUROCK (Optional) APP- G-19 gypsum or gypsum Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Gypsum -Fiber Roof Board OB500 APP-SA-H TA APP-TA -112.5 plank (Optional) additional layers(s) of Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- base insulation and/or min. (Optional) APP- G-20 gypsum or gypsum Shield or Multi -Max FA3 M-OSFA 0.25-inch SECUROCK Gypsum- M-OSFA APP-SA-H TA APP-TA -202.5 plank Fiber Roof Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 85 of 94 NNEMO I etc. TABLE 6A: GYPSUM DECKS - REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Notes 1 & 12) Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Existing, sound poured Min. 0.25-inch SECUROCK (Optional) APP- G-21 gypsum or gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Gypsum -Fiber Roof Board CR-20 APP-SA-H TA APP-TA -240.0 plank (Optional) additional layers(s) of Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, base insulation and/or min. (Optional) APP- G 22 gypsum or gypsum ACFoam III, ENRGY 3, Polytherm H, H-Shield, H- CR-20 0.25-inch SECUROCK Gypsum- CR-20 APP-SA-H TA APP-TA -257.5 plank Shield CG or Multi -Max FA3 Fiber Roof Board HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, G-23 gypsum or gypsum Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 plank Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) additional layers(s) of G-24 gypsum or gypsum Polytherm H or H-Shield OB500 base insulation OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -112.5 plank Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Min. 0.25-inch SECUROCK G-25 gypsum or gypsum Polytherm H or H-Shield or min. 2.0 pcf, Insulfoam OB500 Gypsum -Fiber Roof Board OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -112.5 plank Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H- G-26 gypsum or gypsum Shield or Multi -Max FA3 M-OSFA Min. 0.25-inch DensDeck Prime M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 plank (Optional) additional layers(s) of Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, H base insulation and/or min. G 27 gypsum or gypsum Shield or Multi -Max FA3 M-OSFA 0.25-inch SECUROCK Gypsum- M-OSFA SBS-SA H (Optional) SBS TA SBS-TA 202.5 plank Fiber Roof Board Min. 1.5-inch, min. 2.0 pcf EPS insulation board, Existing, sound poured Polytherm, ACFoam II, Polytherm G, ACFoam III, G-28 gypsum or gypsum ENRGY 3, Polytherm H, H-Shield, H-Shield CG or CR-20 Min. 0.25-inch DensDeck Prime CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 plank Multi -Max FA3 Existing, sound poured Min. 0.25-inch SECUROCK G-29 gypsum or gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 plank (Optional) additional layers(s) of Existing, sound poured Min. 1.5-inch Polytherm, ACFoam II, Polytherm G, base insulation and/or min. G-30 gypsum or gypsum ACFoam III, ENRGY 3, Polytherm H, H-Shield, H- CR-20 CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -257.5 0.25-inch SECUROCK Gypsum - plank Shield CG or Multi -Max FA3 Fiber Roof Board COLD APPLIED BASE PLY: NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 86 of 94 NNEMO I etc. TABLE 6A: GYPSUM DECKS — REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. (Notes 1 & 12) Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Min.0.25-inch DensDeck, DensDeck Min. 1-inch Polytherm, ACFoam II, Polytherm G, Prime, DEXcell FA Glass Mat Roof Existing, sound poured ACFoam III, EnergyGuard Polyiso Insulation, Board, SECUROCK Gypsum -Fiber SBS-CA1, (Optional) SBS- SBS-CA1, SBS- G-31 gypsum or gypsum ENRGY 3, Polytherm H, H-Shield ISO 95+ GL, Multi- M-OSFA Roof Board or SECUROCK Glass -Mat M-OSFA -120.0 plank Max FA3, RESISTA or UltraMax or min. 2-inch Roof Board, min. 7/16-inch DEXcell SBS-CA2 CAI, SBS-CA2 CA2,APP-CA1 DECKMATE Plus or DECKMATE Plus FA Cement Roof Board or min. 0.5-inch SEW ROCK Cement Roof Board Min. 0.25-inch DensDeck Prime Min. 1-inch Polytherm or ACFoam II, Polytherm G, or DEXcell FA Glass Mat Roof Existing, sound poured ACFoam III, EnergyGuard Polyiso Insulation, Board, min. 7/16-inch DEXcell SBS-CA1, SBS- G-32 gypsum or gypsum ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, M-OSFA Cement Roo Roo nf Board or min. 0.5- M-OSFA SBS-CA1 None CA2, APP-CA1 -127.5 plank Multi -Max FA3, RESISTA or UltraMax or min. 2- inch Cement Roof inch DECKMATE Plus or DECKMATE Plus FA Board Min. 1-inch Polytherm or ACFoam II, Polytherm G, Existing, sound poured ACFoam III, EnergyGuard Polyiso Insulation, Min. 0.25-inch SECUROCK SBS-CA1, SBS-CA1, SBS- G-33 gypsum or gypsum ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, M-OSFA Gypsum -Fiber Roof Board M-OSFA SBS-CA2 None CA2, APP-CA1 -127.5 plank Multi -Max FA3, RESISTA or UltraMax or min. 2- inch DECKMATE Plus or DECKMATE Plus FA Min.0.25-inch DensDeck, DensDeck Min. 1-inch Polytherm or ACFoam II, Polytherm G, Prime, DEXcell FA Glass Mat Roof Existing, sound poured ACFoam III, EnergyGuard Polyiso Insulation, Board, SECUROCK Gypsum -Fiber SBS-CA1, SBS-CA1, SBS- G-34 gypsum or gypsum ENRGY 3, Polytherm H, H-Shield, ISO 95+ GL, M-OSFA Roof Board or SECUROCK Glass -Mat M-OSFA None -202.5 plank Multi -Max FA3, RESISTA or UltraMax or min. 2- Roof Board, min. 7/16-inch DEXcell SBS-CA2 CA2 inch DECKMATE Plus or DECKMATE Plus FA Cement Roof Board or min. 0.5-inch SEW ROCK Cement Roof Board Min. 0.25-inch DensDeck Prime, Existing, sound poured Min. 1-inch Polytherm, ACFoam II, Polytherm G, DEXcell FA Glass Mat Roof Board SBS-CA1, (Optional) SBS- SBS-CA1, SBS- G-35 gypsum or gypsum ACFoam III, ENRGY 3, Polytherm H, H-Shield or OB500 or SECUROCK Gypsum -Fiber OB500 SBS-CA2 CAI, SBS-CA2 CA2, APP-CA1 -112.5 plank Multi -Max FA3 Roof Board Existing, sound poured Min. 1-inch Polytherm, ACFoam II, Polytherm G, Min. 0.25-inch DensDeck Prime SBS-CA1, (Optional) SBS- SBS-CA1, SBS- G-36 gypsum or gypsum ACFoam III, ENRGY 3, Polytherm H, H-Shield or CR-20 or SECUROCK Gypsum -Fiber CR-20 -120.0 plank Multi -Max FA3 Roof Board SBS-CA2 CAI, SBS-CA2 CA2, APP-CA1 Existing, sound poured Min. 1-inch Polytherm, ACFoam II, Polytherm G, Min. 0.25-inch DensDeck Prime G-37 gypsum or gypsum ACFoam III, ENRGY 3, Polytherm H, H-Shield or CR-20 or DEXcell FA Glass Mat Roof CR-20 SBS-CA1 None SBS-CA1, SBS- -127.5 plank Multi -Max FA3 Board CA2, APP-CA1 Existing, sound poured Min. 1-inch Polytherm, ACFoam II, Polytherm G, Min. 0.25-inch SECUROCK SBS-CAI, SBS-CA1 SBS- G-38 gypsum or gypsum ACFoam III, ENRGY 3, Polytherm H, H-Shield or CR-20 Gypsum -Fiber Roof Board CR-20 SBS-CA2 None CA2, APP-CA3 -127.5 plank Multi -Max FA3 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL3654-R27 Revision 25: 09/30/2020 Appendix 1, Page 87 of 94 NNEMO I etc. Deck TABLE 613: GYPSUM DECKS — REROOF ALSYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, Anchor Sheet Base Insulation (TEAR -OFF) BONDED INSULATION, BONDED ROOF COVER Top Insulation Roof Cover (Note 15) System No. (Note 1) Type Fasten Attach Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Note 11) (Notes 6,7,8) (Notes 6,7,8) Elastobase, 9-inch o.c. at min. Min. 1.5-inch Min. 0.25-inch DensDeck, Existing, Elastobase Trufast 4-inch lap and 18- Polytherm, ACFoam II, DensDeck Prime, SECUROCK (Optional) sound poured P, FM-75 or inch o.c. at two, Polytherm G, ACFoam Gypsum -Fiber Roof Board, Min. BP -AA , BP-AA , SBS- SBS-AA, G-40 FM-90 or III, IS095+GL, Hot asphalt 0.75-inch Fesco Board Hot asphalt SBS-TA, -45.0 gypsum or Elastovent Twin Loc- equally spaced, Polytherm H, H-Shield, (homogeneous) or min. 0.5-inch SBS-AA AA, SBS-TA APP TA gypsum plank or Polyglass Nails staggered center ENRGY 3 or Multi -Max Structodek High Density or APP-TA G2 Base rows FA3 Fiberboard Roof Insulation NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for FL1654-R27 Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020 ©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 88 of 94 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS 'STEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System Substrate No. (Notes 1 & 12) Type Attach Type Attach Base Ply Ply MDP Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) ASPHALT OR TORCH APPLIED BASE PLY: Existing Min. 0.25-inch DensDeck, DensDeck BP -AA, SBS (Optional) AA, SBS-TA R-1 asphaltic roof Min. 1.5-inch Multi -Max FA3 D-IS Prime or SECUROCK Gypsum -Fiber D-IS AA, SBS-TA, -TASBS AA, SBS-TA or APP-TA or or APP-SBS-AA, or APP-TA -67.5 Roof Board APP-TA Min. 0.25-inch DensDeck, DensDeck BP -AA, SBS ExistingMin. 1.5-inch Polytherm, ACFoam II or ENRGY y D-IS Prime or SECUROCK Gypsum -Fiber D-IS AA, SBS-TA, (Optional) AA, SBS (Optional) SBS TA, -90.0 asphaltic roof 3 or min. 2.0 pcf Insulfoam Roof Board APP-TA or AA, SBS-TA or APP-TA or APP-, or APP-TA Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Min. 0.25-inch DensDeck, DensDeck BP -AA, SBS (Optional) BP -AA, SBS- SBS-AA, SBS-TA, R-3 asphaltic roof H-Shield or ISO 95+GL OB500 Prime or SECUROCK Gypsum -Fiber OB500 AA56 5-TA, , SBS-TA AA, SBS-TA or APP-TA or APP-TA _127.5 Roof Board AA Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, Min. 0.25-inch SECUROCK Gypsum- BP -AA, SBS- (Optional) BP -AA, SBS- SBS-AA, SBS-TA, R 4 asphaltic roof H-Shield or Multi -Max FA3 M-OSFA Fiber Roof Board M-OSFA AA, SBS-TA, AA, SBS-TA or APP-TA or APP-TA _157.5 APP Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Existing min. 1.3-inch Polytherm G, ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- BP -AA, SBS- (Optional) BP -AA, SBS- R-5 asphaltic roof 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H- CR-20 Fiber Roof Board CR-20 AA AA SBS-AA -225.0 Shield CG or ENRGY 3 or min. 2.0 pcf Insulfoam Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Existing min. 1.3-inch Polytherm G, ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- R-6 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H- CR-20 CR-20 APP-TA (Optional) APP-TA APP-TA -232.5 asphaltic roof Shield CG or ENRGY 3 or min. 2.0 pcf Fiber Roof Board Insulfoam SELF -ADHERING BASE PLY: (Optional) additional layers(s) of base Existing insulation and/or min. 0.25-inch (Optional) SBS-SA, SBS-SA, APP-SA, R 7 asphaltic roof Min. 1.5-inch Multi -Max FA3 D-IS SECUROCK Gypsum -Fiber Roof Board D-IS SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA _67.5 or DensDeck Prime R 8 Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3 Min. 0.25-inch DensDeck Prime D-IS SBS-SA (Optional) SBS-SA, SBS-SA, APP-SA, 72.5 asphaltic roof or Multi -Max FA3 or min. 2.0 pcf Insulfoam SBS-TA, APP-TA SBS-TA, SBS-TA, APP-TA Existing (Optional) additional layers(s) of base R 9 asphaltic roof Min. 1.5 inch min. 2.0 pcf Insulfoam p D-IS insulation D-IS SBS-SA (Optional) SBS-SA SBS-SA -90.0 Existing Min. 0.25-inch SECUROCK Gypsum (Optional) SBS-SA, SBS-SA, APP-SA, R 10 asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS Fiber Roof Board D-IS SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA 90.0 (Optional) additional layers(s) of base R-11 Existing Min. 1.5-inch Polytherm, ACFoam II or ENRGY D-IS insulation and/or min. 0.25-inch D-IS SBS-SA (Optional) SBS-SA, SBS-SA, APP-SA, _90.0 asphaltic roof 3 SECUROCK Gypsum -Fiber Roof Board SBS-TA, APP-TA SBS-TA, APP-TA NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for FL1654-R27 Revision 25: 09/30/2020 Appendix 1, Page 89 of 94 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS 'STEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. Substrate (Notes 1 & 12) Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) SBS-SA, SBS-SA, APP-SA, R-12 asphaltic roof Polytherm H or H-Shield or min. 2.0 pcf OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA 72.5 Insulfoam Existing (Optional) additional layers of base R-13 asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 insulation OB500 SBS-SA (Optional) SBS-SA SBS-SA -120.0 Existing Min. 0.25-inch SECUROCK Gypsum- (Optional) SBS-SA, SBS-SA, APP-SA, R-14 asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Fiber Roof Board OB500 SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA 120.0 Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) additional layers(s) of base (Optional) SBS-SA, SBS-SA, APP-SA, R-15 OB500 insulation and/or min. 0.25-inch OB500 SBS-SA _127.5 asphaltic roof Polytherm H or H-Shield SECUROCK Gypsum -Fiber Roof Board SBS TA, APP-TA SBS TA, APP-TA R-16 Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, M-OSFA Min. 0.25-inch DensDeck Prime M-OSFA SBS-SA (Optional) SBS-SA, SBS-SA, APP-SA, 72.5 asphaltic roof H-Shield or Multi -Max FA3 SBS-TA, APP-TA SBS-TA, APP-TA Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) additional layers(s) of base (Optional) SBS-SA, SBS-SA, APP-SA, R-17 M-OSFA insulation and/or min. 0.25-inch M-OSFA SBS-SA 157.5 asphaltic roof H-Shield or Multi -Max FA3 SECUROCK Gypsum -Fiber Roof Board SBS-TA, APP-TA SBS-TA, APP-TA Min. 1.5-inch min. 2.0 pcf Insulfoam, Min. 2- inch Polytherm, ACFoam II, min. 1.5-inch Existing Ultra -Max or Multi -Max FA-3, min. 1.3-inch (Optional) SBS-SA, SBS-SA, APP-SA, R-18 asphaltic roof Polytherm G, ACFoam III or min. 1.0-inch ISO CR-20 Min. 0.25-inch DensDeck Prime CR-20 SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA 72 5 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 Existing (Optional) additional layers(s) of base R-19 asphaltic roof Min. 1.5-inch min. 2.0 p pcf Insulfoam CR-20 insulation CR-20 SBS-SA (Optional) SBS SA SBS-SA 240.0 R-20 Existing Min. 1.5-inch min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 SBS SA (Optional) SBS-SA, SBS-SA, APP-SA, 240.0 asphaltic roof Fiber Roof Board SBS-TA, APP-TA SBS-TA, APP-TA (Optional if Top Layer Insulation installed) (Optional if Base Layer Insulation Existing Min. 1.5-inch Ultra -Max or Multi -Max FA-3, installed) additional layers(s) of base (Optional) SBS-SA, SBS-SA, APP-SA, R-21 asphaltic roof min. 1.3-inch Polytherm G, ACFoam III or min. CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA -240.0 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H SECUROCK Gypsum -Fiber Roof Board Shield CG or ENRGY 3 (Optional if Base Layer Insulation Existing (Optional if Top Layer Insulation installed) installed) additional layers(s) of base (Optional) SBS-SA, SBS-SA, APP-SA, R 22 asphaltic roof Min. 2-inch Polytherm, ACFoam II, ENRGY-3, CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA SBS-TA, APP-TA SBS-TA, APP-TA 247.5 Polytherm H or H-Shield SECUROCK Gypsum -Fiber Roof Board HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY: NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 90 of 94 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS 'STEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System Substrate MDP No. (Notes 1 & 12) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) (Optional) additional layers(s) of base Existing insulation and/or min. 0.25-inch R-23 Min. 1.5-inch Multi -Max FA3 D-IS D-IS APP-SA-H (Optional) APP-TA APP-TA -67.5 asphaltic roof SECUROCK Gypsum -Fiber Roof Board or DensDeck Prime Existing Min. 0.25-inch SECUROCK Gypsum- R-24 asphaltic roof Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS Fiber Roof Board D-IS APP-SA-H (Optional) APP-TA APP-TA -90.0 Existing Min. 1.5-inch Polytherm, ACFoam II or ENRGY (Optional) additional layers(s) of base R-25 D-IS insulation and/or min. 0.25-inch D-IS APP-SA-H (Optional) APP-TA APP-TA -90.0 asphaltic roof 3 SECUROCK Gypsum -Fiber Roof Board Existing Min. 0.25-inch SECUROCK Gypsum- R-26 asphaltic roof Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Fiber Roof Board OB500 APP-SA-H (Optional) APP-TA APP-TA -120.0 Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) additional layers(s) of base R 27 OB500 insulation and/or min. 0.25-inch OB500 APP-SA-H (Optional) APP-TA APP-TA -127.5 asphaltic roof Polytherm H or H-Shield SECUROCK Gypsum -Fiber Roof Board Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) additional layers(s) of base R 28 M-OSFA insulation and/or min. 0.25-inch M-OSFA APP-SA-H (Optional) APP-TA APP-TA -157.5 asphaltic roof H-Shield or Multi -Max FA3 SECUROCK Gypsum -Fiber Roof Board Min. 1.5-inch Ultra -Max or Multi -Max FA-3, (Optional) additional layers(s) of base R 29 Existing min. 1.3-inch Polytherm G, ACFoam III or min. CR-20 insulation and/or min. 0.25-inch CR-20 APP-SA-H (Optional) APP-TA APP-TA -240.0 asphaltic roof 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H- SECUROCK Gypsum -Fiber Roof Board Shield CG or ENRGY 3 (Optional) additional layers(s) of base R-30 Existing Min. 2-inch Polytherm, ACFoam II, ENRGY-3, CR-20 insulation and/or min. 0.25-inch CR-20 APP-SA-H (Optional) APP-TA APP-TA -247.5 asphaltic roof Polytherm H or H-Shield SECUROCK Gypsum -Fiber Roof Board HYBRID SYSTEMS WITH SELF -ADHERING SBS BASE PLY: (Optional) additional layers(s) of base Existing insulation and/or min. 0.25-inch R-31 asphaltic roof Min. 1.5-inch Multi -Max FA3 D-IS SECUROCK Gypsum -Fiber Roof Board D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -67.5 or DensDeck Prime R-32 Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3 D-IS Min. 0.25-inch DensDeck Prime D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 asphaltic roof or Multi -Max FA3 or min. 2.0 pcf Insulfoam R-33 Existing Min. 1.5-inch min. 2.0 pcf Insulfoam D-IS Min. 0.25-inch SECUROCK Gypsum- D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -90.0 asphaltic roof Fiber Roof Board (Optional) additional layers(s) of base R-34 Existing Min. 1.5-inch Polytherm, ACFoam II or ENRGY D-IS insulation and/or min. 0.25-inch D-IS SBS-SA-H (Optional) SBS-TA SBS-TA -90.0 asphaltic roof 3 SECUROCK Gypsum -Fiber Roof Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 91 of 94 NNEMO I etc. 'STEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER 3 Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System Substrate MDP No. (Notes 1 & 12) Type Attach Type Attach Base Ply Ply Cap Ply (psf) (Notes 6,7,8) (Notes 6,7,8) Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, R-35 Existing Polythermpcf H or H-Shield or min. 2.0 P OB500 Min. 0.25-inch DensDeck Prime OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 asphaltic roof Insulfoam R-36 Existing Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -120.0 asphaltic roof Fiber Roof Board (Optional) additional layers(s) of base R 37 Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, OB500 insulation and/or min. 0.25-inch OB500 SBS-SA-H (Optional) SBS-TA SBS-TA -127.5 asphaltic roof Polytherm H or H-Shield SECUROCK Gypsum -Fiber Roof Board R 38 Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, M-OSFA Min. 0.25-inch DensDeck Prime M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 asphaltic roof H-Shield or Multi -Max FA3 Existing Min. 1.5-inch Polytherm, ACFoam II, ENRGY 3, (Optional) additional layers(s) of base R-39 M-OSFA insulation and/or min. 0.25-inch M-OSFA SBS-SA-H (Optional) SBS-TA SBS-TA -157.5 asphaltic roof H-Shield or Multi -Max FA3 SECUROCK Gypsum -Fiber Roof Board Min. 1.5-inch min. 2.0 pcf Insulfoam, Min. 2- inch Polytherm, ACFoam II, min. 1.5-inch R-40 Existing Ultra -Max or Multi -Max FA-3, min. 1.3-inch CR-20 Min. 0.25-inch DensDeck Prime CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -72.5 asphaltic roof Polytherm G, ACFoam III or min. 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H-Shield CG or ENRGY 3 R-41 Existing Min. 1.5-inch min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 asphaltic roof Fiber Roof Board Min. 1.5-inch Ultra -Max or Multi -Max FA-3, (Optional) additional layers(s) of base R 42 Existing min. 1.3-inch Polytherm G, ACFoam III or min. CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -240.0 asphaltic roof 1.0-inch ISO 95+GL, Polytherm H, H-Shield, H Shield CG or ENRGY 3 SECUROCK Gypsum -Fiber Roof Board (Optional) additional layers(s) of base R-43 Existing Min. 2-inch Polytherm, ACFoam II, ENRGY-3, CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA-H (Optional) SBS-TA SBS-TA -247.5 asphaltic roof Polytherm H or H-Shield SECUROCK Gypsum -Fiber Roof Board COLD APPLIED BASE PLY: Existing (Optional) Min. 1-inch Polytherm, ACFoam II, Min. 0.25-inch DensDeck Prime, SBS-CA1, (Optional) SBS-CA1, SBS-CA1, SBS- R-44 asphaltic roof Polytherm G, ACFoam III, ENRGY 3, Polytherm D-IS DEXcell FA Glass Mat Roof Board or D-IS SBS-CA2 SBS-CA2 CA2, APP-CA1 -90.0 H or H-Shield SECUROCK Gypsum -Fiber Roof Board NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.3654-1127 Revision 25: 09/30/2020 Appendix 1, Page 92 of 94 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS 'STEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. Substrate (Notes 1 & 12) Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) (Optional) Min. 1-inch Polytherm, ACFoam II, Min. 0.25-inch DensDeck, DensDeck Polytherm G, ACFoam III, EnergyGuard Polyiso Prime, DEXcell FA Glass Mat Roof Existing Insulation, ENRGY 3, Polytherm H, H-Shield M-OSFA, Board, SECUROCK Gypsum -Fiber Roof M-OSFA or SBS-CAl, (Optional) SBS-CA1, SBS-CAl, SBS- R-45 Board or SECUROCK Glass -Mat Roof -120.0 asphaltic roof ISO 95+ GL, Multi -Max FA3, RESISTA or M-PG1 Board, min. 7/16-inch DEXcell Cement M-PG1 SBS-CA2 SBS-CA2 CA2, APP-CA1 UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA Roof Board or min. 0.5-inch SECUROCK Cement Roof Board (Optional) Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Min. inch DensDeck Prime or DEX0.cell F FA Glass Mat Roof Board, min. DEXcell R-46 Existing Polyiso Insulation, ENRGY 3, Polytherm H, H- M-OSFA, inch DEXcell Cement Roof Board M-OSFA, M- SBS-CAl None SBS-CA1, SBS- 127.5 asphaltic roof Shield, ISO 95+ GL, Multi -Max FA3, RESISTA or M-PG1 PG1 CA2, APP-CA1 UltraMax or min. 2-inch DECKMATE Plus or or m or min. 0.5 inch SECUROCK Cement DECKMATE Plus FA Roof Board (Optional) Min. 1-inch Polytherm or ACFoam II, Polytherm G, ACFoam III, EnergyGuard Existing Polyiso Insulation, ENRGY 3, Polytherm H, H- M-OSFA, Min. 0.25-inch SECUROCK Gypsum- M-OSFA, M- SBS-CA1, SBS-CA1, SBS R-47 asphaltic roof Shield, ISO 95+ GL, Multi -Max FA3, RESISTA or M-PG1 Fiber Roof Board PG1 SBS-CA2 None CA2, APP-CA1 127.5 UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA (Optional) Min. 1-inch Polytherm or ACFoam Min. 0.25-inch DensDeck, DensDeck II, Polytherm G, ACFoam III, EnergyGuard Prime, DEXcell FA Glass Mat Roof Existing Polyiso Insulation, ENRGY 3, Polytherm H, H- M-OSFA, Board, SECUROCK Gypsum -Fiber Roof M-OSFA, M- SBS-CA1, SBS-CA1, SBS- R 48 Board or SECUROCK Glass -Mat Roof None -157.5 asphaltic roof Shield, ISO 95+ GL, Multi -Max FA3, RESISTA or M-PG1 Board, min. 7/16-inch DEXcell Cement PG1 SBS-CA2 CA2 UltraMax or min. 2-inch DECKMATE Plus or DECKMATE Plus FA Roof Board or min. 0.5-inch SECUROCK Cement Roof Board Existing (Optional) Min. 1-inch Polytherm, ACFoam II, Min. 0.25-inch DensDeck Prime, SBS-CAl, (Optional) SBS-CAl, SBS-CAl, SBS- R 49 Polytherm G, ACFoam III, ENRGY 3, Polytherm OB500 DEXcell FA Glass Mat Roof Board or OB500 -120.0 asphaltic roof H, H-Shield or Multi -Max FA3 SECUROCK Gypsum -Fiber Roof Board SBS-CA2 SBS-CA2 CA2, APP-CA1 (Optional) Min. 1-inch Polytherm, ACFoam II, R-50 Existing Polytherm G, ACFoam III, ENRGY 3, Polytherm OB500 Min. 0.25-inch DensDeck Prime or OB500 SBS-CA1 None SBS-CA1, SBS- -127.5 asphaltic roof H, H-Shield or Multi -Max FA3 DEXcell FA Glass Mat Roof Board CA2, APP-CA1 Existing (Optional) Min. 1-inch Polytherm, ACFoam II, Min. 0.25-inch SECUROCK Gypsum- SBS-CA1, SBS-CA1, SBS- R-51 asphaltic roof Polytherm G, ACFoam III, ENRGY 3, Polytherm OB500 Fiber Roof Board OB500 SBS-CA2 None CA2, APP-CA1 -127.5 H, H-Shield or Multi -Max FA3 Existing (Optional) Min. 1-inch Polytherm, ACFoam II, Min. 0.25-inch DensDeck Prime or SBS-CA1, (Optional) SBS-CA1, SBS-CA1, SBS- R-52 asphaltic roof Polytherm G, ACFoam III, ENRGY 3, Polytherm CR-20 SECUROCK Gypsum -Fiber Roof Board CR-20 SBS-CA2 SBS-CA2 CA2, APP-CA1 -120.0 H, H-Shield or Multi -Max FA3 NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 93 of 94 NNEMO I etc. TABLE 7A: RECOVER APPLICATIONS 'STEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) System No. Substrate (Notes 1 & 12) Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) (Notes 6,7,8) (Notes 6,7,8) (Optional) Min. 1-inch Polytherm, ACFoam II, R-53 Existing Polytherm G, ACFoam III, ENRGY 3, Polytherm CR-20 Min. 0.25-inch DensDeck Prime or CR-20 SBS-CA1 None SBS-CA1, SBS- -127.5 asphaltic roof DEXcell FA Glass Mat Roof Board CA2, APP-CA1 H, H-Shield or Multi -Max FA3 (Optional) Min. 1-inch Polytherm, ACFoam II, Existing Min. 0.25-inch SECUROCK Gypsum- SBS-CAl, SBS-CAl, SBS- R-54 asphaltic roof Polytherm G, ACFoam III, ENRGY 3, Polytherm CR-20 Fiber Roof Board CR-20 SBS-CA2 None CA2, APP-CA1 -127.5 H, H-Shield or Multi -Max FA3 Existing (Optional) Min. 1-inch ENRGY 3, Polytherm H, Min. 0.25-inch DensDeck Prime or SBS-CA1, SBS-CA1, SBS R-55 asphaltic roof H-Shield, Multi -Max FA3 CR-20 SECUROCK Gypsum -Fiber Roof Board CR-20 SBS-CA2 None CA2 232.5 RECOVERTABLE 7B: • SYSTEM TYPE F: NON -INSULATED, BONDED ROOF COVER Substrate Roof Cover (Note 15) System No. Primer MDP (psf) Base Ply Ply Cap Ply (Notes 1 & 12) R-56 Existing asphaltic roof PG100 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP -AA, SBS- SBS-AA, SBS-TA, APP-TA -45.0 AA, SBS-TA or APP-TA Existing fully -adhered, granule- None Polyflex, torch -applied (Optional) Polyflex, torch -applied APP-TA 362.5 surfaced surfaced modified bitumen R-58 Existing fully -adhered, granule- PG100 Polyflex, torch -applied (Optional) Polyflex, torch -applied APP-TA 445.0 surfaced modified bitumen NEMO ETC, LLC Certificate of Authorization #32455 ©2018 NEMO ETC, LLC 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R25 for F1.1654-1127 Revision 25: 09/30/2020 Appendix 1, Page 94 of 94