Loading...
HomeMy WebLinkAboutTruss Details V Y � , Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 A-1 ROOF These truss designs rely on lumber values established by others. TRUSSES A FLORIDA CORPORATION RE:Job 57236R A-1 Roof Trusses 4451 St Lucie Blvd Site Information: Fort Pierce,FL 34946 Customer Info: MASTERPIECE BUILDERS Project Name: DOYLE RES Lot/Block: Model: Address:4900 WATERSONG WAY Subdivision: City: Port St. Lucie County:St. Lucie State: FL Name Address and License#of Structural Engineer of Record, If there is one,for the building. Name:James Bushouse License#:20311 Address: 1176 SW 4th Court City: Boca Raton, FL 33432 General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.5 Wind Code:ASCE 7-10 Wind Speed: 180 MPH Roof Load:46.0 psf Floor Load:0.0 psf This package includes 35 individual,dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date No. Seal# Truss Name Date No. Seal# Truss Name Date 1 A0272860 A01G 1/14/14 13 A0272872 D03 1/14/14 25 A0272884 E08 1/14/14 2 A0272861 A02 1/14/14 14 A0272873 DT1 1/14/14 26 A0272885 FTG1 1/14/14 3 A0272862 A03 1/14/14 15 A0272874 DT2 1/14/14 27 A0272886 HJ5 1/14/14 4 A0272863 B01 G 1/14/14 16 1 A0272875 E01 G 1/14/14 28 A0272887 HJ5A 1/14/14 5 A0272864 B02 1/14/14 17 A0272876 E02 1/14/14 29 A0272888 HJ6 1/14/14 6 A0272865 B03 1/14/14 18 A0272877 E03 1/14/14 30 A0272889 HJ7 1/14/14 7 A0272866 CA 1/14/14 19 A0272878 E04 1/14/14 31 A0272890 J5 1/14/14 8 A0272867 CJ3 1/14/14 20 A0272879 E04A 1/14/14 32 A0272891 J513 1/14/14 9 A0272868 CJ3B 1/14/14 21 A0272880 E05 1/14/14 33 A0272892 J6 1/14/14 10 A0272869 CJ5 1/14/14 22 A0272881 E06 1/14/14 34 A0272893 J7 1/14/14 11 A0272870 D01G 1/14/14 23 A0272882 E06A 1/14/14 35 A0272894 NP 1/14/14 12 A0272871 D02 1/14/14 24 A0272883 E07 1/14114 Julius Lee,PE I Florida Certification Number 34869 The truss drawing(s) referenced have been prepared by MiTek 1109 Coastal Bay,Boynton Beach,FL 33435 Industries, Inc. under my direct supervision based on the parameters 1/14/14 provided by A-1 Roof Trusses, Ltd. \�\+++ 0S Truss Design Engineer's Name:Julius Lee My license renewal date for the state of Florida is February 28 2015. 34869: NOTE: The seal on these drawings indicate acceptance of =-p : f/ professional engineering responsibility solely for the truss _�0 : -� 5" - W_ 1 1 /2014 components shown. The suitability and use of this component �0 STATE OF for any particular building is the responsibility of the building % FCORIDP. designer, per ANSI/TPI-1 Sec.2. '/� 0NIA�+����. 1109 COASTAL BAY Page 1 of 1 BOYNTON BC,FL 33435 o russ russ ype y 57236R A01 G Roof Special Girder 1 1 Job Reference(optional) A0272860 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:16 2014 Page 1 ID:sf8?Y395JXmOwKJyJLviMGyspll-13QmnLH?ava53ZV WGNQdl ffUtUCUG6di1 oXvMpzvW9D 0 0 0 2-4-0 4-0 0 5-0 0 9 7-710 2-1 12 4 0 15-"15-8-0 2-4-0 1-&0 1-0-0 4-7-7 0-6 10 2.1-15 3-2-6 0-1-10 Scale=127.8 1.5x4= 1.5x4 II 7.00 12 4x8 1.5x4 II 1.5x4 II = tt 10 4.00 12 4x4 Un T3 13 3 T2 2x4 11 2 7 T1 N4 W7 cQ 1 W 1 3 F LA 0.7-8 Bi s• s. e s• 9 8 7 3x4= 10 5x6= 3x4= 3x8= 3x6 II i 2-0.0 13-7-12 i 0-0-0 2-4-0 2-4-0 2-8-0 5-" 4-7-7 9-p&1 q21 5A-5 15-71015-8-0 Plate Offsets(X,Y): [4:0-5-8,0-2-01,[5:0-2-3,0-0-121,[6:0-2-3,0-0-121,[6:0-2-4,0-2-01,[10:0-2-4,0-2-81 0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.97 Vert(LL) 0.07 8-9 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.31 Vert(TL) -0.09 7-8 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.65 Horz(TL) 0.01 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:90 lb FT=0 LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.2 Except: WEBS 2x4 SP No.3*Except* 2-8-0 oc bracing:5-6 W1,W7:2x8 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s):6 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 7=758/Mechanical,10=680/0-8-0 (min.0-1-8) Max Horz 10=177(LC 8) Max Uplift7—699(LC 5),10=911(LC 4) Max Grav7=758(LC 1),10=903(LC 43) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-285/211,3-4=-906/775,4-15=1141/1080,5-15=1141/1080,5-6=-1141/1080 BOT CHORD 1-10—167/294,9-10=607/688,9-16=-714/802,8-16=-714/802 WEBS 2-10=-209/295,3-10=-1011/786,3-9=-247/270,4-9=-361/487,6-7=-712/718, 5-8=-630/643,4-8=-860/840,6-8=-1168/1234 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Refer to girder(s)for truss to truss connections. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 699 lb uplift at joint 7 and 911 lb uplift at joint 10. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 10)Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 11)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)122 lb down and 64 lb up at 5-0-0,and 122 lb down and 64 lb up at 7-1-1 on top chord,and 396 lb down and 319 lb up at 5-0-0,and 81 lb down and 63 lb up at 7-1-1 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 12)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3—72,3-4=-72,4-5=72,5-6=-132(F=-60),7-12=20 Julius Lee,P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach,FL 33435 Job I cuss russ ype ty ��Job A0272860 57236R A01G Roof Special Girder 1 eference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:17 2014 Page 2 ID:sf8?Y395JXmOwKJyJLvjMGyspll-mF_8_hleLCiygj4ip4xsatBfduYj?ZsrGSGSuFzvW9C LOAD CASE(S) Standard Concentrated Loads(Ib) Vert:4=38(B)9=187(B)15=38(B)16=22(B) Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I russ I Ype Y 57236R A02 Half Hip 1 1 Job Reference(optional) A0272861 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:17 2014 Page 1 ID sf8?Y395JXmOwKJyJLvjMGyspll-mF_8_hleLCiygj4ip4xsatBnLuSP?cirGSGSuFzvW9C 0 0 0 2-4-0 4-0.0 7-0-0 11-2-6 15-4-12 15-6.6 2-4-0 1-8-0 3-0-0 4-2-6 4-2-6 '10 Scale=127.5 4x4= 3x4= 1.5x4 11 7.00 Fl2 4 5 6 7 3 Fl 4.00 Fl2 4x4 T2 , 3 1.5x4 11 2 T1 0 10 1 W1 81 6• � s 6• 10 9 3x4= 11 3x6= 3x8= 8 2-0-0 13-6-6 5x6= 0-0-0 2-4-0 2 4 0 48 0 7 0 0 8 4 12 10t'j 015-6 s Plate Offsets(X,Y): [9:0-3-0,0-3-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.48 Vert(LL) -0.15 9-10 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.65 Vert(TL) -0.38 9-10 >413 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.47 Horz(TL) 0.02 9 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:81 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-9-3 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3*Except* MiTek recommends that Stabilizers and required cross W1:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=828/0-8-0 (min.0-1-8),9=590/Mechanical Max Horz 11=284(LC 12) Max Upliftl 1=-584(LC 8),9=473(LC 9) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-659/236,2-3=-500/195,3-4=913/650,4-5—823/668 BOT CHORD 1-11=-209/651,10-11=-579/813,9-10=-730/686 WEBS 2-11=-259/484,3-11=1130/1099,5-10=-39/259,5-9=-884/940 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Refer to girder(s)for truss to truss connections. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 584 lb uplift at joint 11 and 473 lb uplift at joint 9. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 o cuss runs Type City �Ply A0272862 57236R A03 Halt Hip 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:18 2014 Pagge 1 I D:sf8?Y395JXmOwKJyJLvjMGyspll-FSYWCOJG6WgpltfvNoS564kvflsGkxi?U60?QhzvW9B 0-0-0 2-4-0 4-0-0 9-0.0 ll -t12 15-6-6 2.4-0 1.8-0 5-0.0 6-4-12 0 .110 Scale=1:30.1 5xl0 MT20H= 1.5x4 II 4 5 6 7.00 F12 T3ri 4.00 12 46 3 1.5x4 II 2 T1 1 W1 0- 10 Bt s c s 9 8 3x4= 10 3x6= 3x4= 5x6=7 2-0-0 i 13-6-6 5 q p 0-0-0 2-4-0 2 4 0 6-8-0 9-0-0 6-4-12 10 1'J 015-6-6 Plate Offsets(X Y): (4:0-7-8 0-2-0] f8:0-3-0,0-3-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.70 Vert(LL) -0.04 8-9 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.42 Vert(TL) -0.10 8-9 >999 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.99 Horz(TL) 0.02 8 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:83 Ito FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2*Except* TOP CHORD Structural wood sheathing directly applied or 4-5-10 oc purlins. T3:2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. BOT CHORD 2x4 SP No.2 MiTek recommends that Stabilizers and required cross WEBS 2x4 SP No.3*Except* bracing be installed during truss erection,in accordance with W1:2x6 SP No.2 Stabilizer Installation guide. REACTIONS (lb/size) 10=828/0-8-0 (min.0-1-8),8=590/Mechanical Max Horz 10=391(LC 12) Max Upliftl0=-525(LC 12),8=-472(LC 9) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=719/209,2-3=-581/196,3-4=808/523 BOT CHORD 1-10—191/707,9-10=-729/1044,8-9=-637/759 WEBS 2-10=144/417,3-1 0=-1 235/1178,3-9=334/271,4-9=0/281,4-8=-933/783, 5-8=-264/397 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;VuIt=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.Il;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)Plates checked for a plus or minus 0 degree rotation about its center. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8)Refer to girder(s)for truss to truss connections. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 525 lb uplift at joint 10 and 472 lb uplift at joint 8. 10)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. 934869 1109 Coastal Bay Boynton Beach,FL 33435 • Job I russ I russ Type y A0272863 57236R B01 G Roof Special Girder 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:19 2014 Page 1 ID:sfB?Y395JXmOwKJyJLvjMGysplpl-je6vPMJutgyfwl E5xVzKflG9wi3M8jmIZy8zvW9A 0-0-0 2 40 2tO 1-8-0 4-0-0.5.0-0 4-2-0 0 4-2-01�1 0 04t0 1 8 0 16-0-0 2� 18-4-0 Scale=1:33.2 7.0D 12 4x4 4.00 F12 44% 6 7 4x4 2x4 11 3 pp L 2x4 11 2 8 5 {n 3 04 1 9 R4 81 & e e Io 6' a 13 12 11 14 4x4= 10 3x4= 3x4=2-0-0 5x6= 3x8= 14-3.4 3x8= 5x6=, 2-0-12 0_ -0 2-4-0 2-4-0 2-8-0 5-0-0 4-2-0 9-2 4-2-0 13_4o 2-8-0 16-0-0 2. 1841-0 Plate Offsets(X,Y): f10:0-2-4,0-2-121,f14:0-2-4,0-2-121 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.34 Vert(LL) -0.32 11-13 >516 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.92 Vert(TL) -0.36 11-13 >452 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.27 Horz(TL) 0.03 10 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:90 Ib FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-2-1 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 5-8-0 oc bracing. WEBS 2x4 SP No.3`Except* MiTek recommends that Stabilizers and required cross WI:2x8 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 14=499/0-8-0 (min.0-1-8),10=499/0-3-0 (min.0-1-8) Max Horz 14=65(LC 8) Max Upliftl4=-947(LC 4),10—947(LC 5) Max Grav 14=950(LC 43),10=950(LC 42) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=294/215,3-4=-1307/840,4-21_1183/786,5-2111831786,5-22—1183/786, 6-22=1183/786,6-7=1307/840,8-9=-294/215 BOT CHORD 1-14—172/296,13-14=555/1036,13-23—883/1311,12-23=-883/1311,12-24=-883/1311, 11-24=-883/131 1,10-11=-517/1027,9-1 0=-1 72/296 WEBS 2-14=203/309,3-14—1296/894,3-13=282/388,4-13=-262/551,6-11=261/551, 7-11=-282/389,7-1 0=-1 297/894,8-10—203/309,5-11=311/372,5-13=311/372 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)Plate(s)at joint(s)1,3,4,6,7,9,2,14,13,11,10,8 and 5 checked for a plus or minus 0 degree rotation about its center. 5)Plate(s)at joint(s)12 checked for a plus or minus 4 degree rotation about its center. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 947 lb uplift at joint 14 and 947 Ib uplift at joint 10. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 10)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)122 Ib down and 64 Ib up at 5-0-0,122 Ib down and 64 Ib up at 7-0-12,122 Ib down and 64 Ib up at 9-0-12,122 Ib down and 64 Ib up at 9-3-4,and 122 Ib down and 64 Ib up at 11-3-4,and 122 Ib down and 64 Ib up at 13-4-0 on top chord,and 396 Ib down and 319 Ib up at 5-0-0,81 Ib down and 63 Ib up at 7-0-12,81 Ib down and 63 Ib up at 9-0-12,81 Ib down and 63 Ib up at 9-3-4,and 81 Ib down and 63 Ib up at 11-3-4,and 396 lb down and 319 Ib up at 13-3-4 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Julius Lee,P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach,FL 33435 • Job I russ I russ I ype uty Ply A0272863 57236R B01 G Roof Special Girder 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:19 2014 Page 2 ID:sf8?Y395JXmOwKJyJLvjMGyspll-je6vPMJutgyfwlE5xVzKflG9wi3fTZJ8jmlZy8zv 9A LOAD CASE(S) Standard Uniform Loads(plf) Vert:1-3=-72,3-4=-72,4-6=72,6-7=-72,7-9=72,15-18=-20 Concentrated Loads(Ib) Vert:4=38(F)6=38(F)12=43(F)13=187(F)11=187(F)5=77(F)21=38(F)22=38(F)23=22(F)24=22(F) Julius Lee,P.E.#34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I cuss I ype Uty Ply A0272864 57236R B02 Roof Special 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:20 2014 Page 1 ID:sf8?Y395JXmOwKJyJLvjMGyspll-BggHdiKWe74WYApH VCUZBVpJ96ZwC?YIyQV6VazvW99 0-0-0 2-4-0 2-4-0 1-8-0 4-0.0 3.0.0 7-0-0 4A-0 11-4-0 3-0-0 14-4-0 1-10-7 16-2-7 2-1-9 18- -0 Scale=1.33.2 4x4= 4x4= 7.00 12 4 5 4.00 12 44 6 4x4 1.5x4 II 3 1.5x4 II 7 2 7 c% 2 1 1 1 8 B ill to tr 6' c 12 11 10 9 13 3x4= 3x4— 3x4= 3x6= 3x4= 3x4=2-0-0 3x6= 14-3-4 i 2-0-12 2-4-0 7-0-0 11-4-0 16-2-7 18A-0 2-4-0 443-0 4A-0 4-10-7 1 2-1-9 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.44 Vert(LL) 0.10 12-13 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.28 Vert(TL) -0.11 12-13 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.33 Horz(TL) 0.02 9 n/a n/a BCDL 10.0 Code FBC2010ITP12007 (Matrix-M) Weight:85 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-5-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3*Except* MiTek recommends that Stabilizers and required cross W1:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 13=843/0-8-0 (min.0-1-8),9=844/0-3-2 (min.0-1-8) Max Horz 13=104(LC 12) Max Upliftl3=-600(LC 8),9=-601(LC 9) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2—649/203,2-3=493/170,3-4_1019/684,4-5=917/700,5-6—1019/684,6-7=-495/171,7-8=-651/205 BOT CHORD 1-13=-180/639,12-13=-307/702,11-12=-287/730,10-11=-287/730,9-10=-203/699,8-9=-181/642 WEBS 2-13=-246/475,3-13=-1199/1115,6-9=-1199/1115,7-9=-246/475 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 600 lb uplift at joint 13 and 601 lb uplift at joint 9. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E.#34869 1109 Coastal Bay Boynton Beach,FL 33435 ocusscuss A027286 YPe tY y 5 57236R �B4O3 1,100FSPECIAL 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print 7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:212014 Page 1 ID:sf6?Y395JXmOwKJyJLvjMGyspll-f1Efg2L8PRCN9KOT2w?okjMP1 VtHxS8RB4Ef10zvW98 2-4-0 1-8 0 4-0-0 5 0 0 O 2�0 0�2 0�0 5-0-0 14-0-0 1 8-0 16-0-0 2-4-0 18-4-0 0 0 0 2-0 0 Scale=1,33.2 4x4= 4 7.00 12 T 2 4.00 F12 4x6 5 4x6 1.5x4 II 3 1.5x4 II 2 6 1 T1 1 W1 W1 7 rj 81 B1 e � 0 B e s s 10 3x6= 5x8= 3x6= 3x4= 3x4= 2-0-0 14-3-4 2-0.12 0 0-0 2 4-0 2-4-0 -10-0 9-2 6-10-0 16-0-0 2� 18-4-0 Plate Offsets(X,Y): [4:0-2-0,0-2-81,[9:0-4-0,0-3-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.75 Vert(LL) -0.04 9-10 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.40 Vert(TL) -0.09 9-10 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.37 Horz(TL) 0.02 8 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:89 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-3-13 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3*Except* MiTek recommends that Stabilizers and required cross Wl:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 10=843/0-8-0 (min.0-1-8),8=843/0-3-2 (min.0-1-8) Max Horz 10=168(LC 11) Max Upliftl0=-582(LC 12),8—582(LC 13) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-691/201,2-3=566/192,3-4—1082/594,4-5=1082/594,5-6=-566/192,6-7=-691/201 BOT CHORD 1-10—183/681,9-10—442/898,8-9=299/898,7-8_183/681 WEBS 2-10—133/378,3-10—1471/1254,3-9=247/262,4-9=23/274,5-9=-249/263,5-8=-1471/1254,6-8=-133/378 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 582 lb uplift at joint 10 and 582 lb uplift at joint 8. 7)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I russ I ype Uty Ply A0272866 57236R GA Jack-Open 16 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run: ID s vf8?Y395JXmOwKJyJL MGyspll-fl Efg2L8PRCN9KOT 1 2w?okjMa nc.Tue n xVxXzRB4Ef10zvW98 0-0-0 1-0-0 1-0-0 4.00 12 Scale=1:6.7 i 1 � T1 B1 2x4= 0-0-0 1-0-0 1-0-0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.05 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.13 Vert(TL) 0.00 4 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 10.0 Code FBC2010lrP12007 (Matrix-M) Weight:3 lb FT=0 LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 2=61/Mechanical,4=32/Mechanical Max Horz 2=-94(LC 8),4=125(LC 8) Max Uplift2—80(LC 8),4—47(LC 8) Max Grav2=61(LC 1),4=35(LC 3) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-313/105 BOT CHORD 1-4=-103/325 NOTES 1)Wind:ASIDE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5)Refer to girder(s)for truss to truss connections. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 80 lb uplift at joint 2 and 47 lb uplift at joint 4. 7)Non Standard bearing condition. Review required. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 o russ russ ype y A0272867 57236R CJ3 Jack-Open 167 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print 7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:22 2014 Page 1 ID:sf8?Y395JXmOwKJyJLvjMGyspll-7Dol20MrnAIKEn UzgcdW 1 HwucXv8wgyxbPk_DZTzvW97 0-0-0 3-0 0 3-0-0 Scale=1:9.8 3x4 II 4.00 F12 2 T1 1 W1 F] B1 2x4 �e 5 3x6 II no 2.0.12 3-0-0 Plate Offsets(X,Y): f2:0-3-7,0-0-121 LOADING(psf) SPACING 2-0-0 CSI DEFL in floc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.64 Vert(LL) -0.00 5 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.76 Vert(TL) 0.00 5 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.15 Horz(TL) 0.08 3 n/a n/a BCDL 10.0 Code FBC2010fTP12007 (Matrix-M) Weight:11 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x6 SP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=-188/Mechanical,4=-198/Mechanical,5=657/0-3-2 (min.0-1-8) Max Horz5=90(LC 8) Max Uplift3=-188(LC 1),4—198(LC 1),5=-857(LC 8) Max Grav3=223(LC 8),4=239(LC 8),5=657(LC 1) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. WEBS 2-5=464/1157 NOTES 1)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;porch left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5)Refer to girder(s)for truss to truss connections. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 188 lb uplift at joint 3,198 lb uplift at joint 4 and 857 lb uplift at joint 5. 7)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. 934869 1109 Coastal Bay Boynton Beach,FL 33435 o cuss russ ype ty y 57236R CJ3B Jack-Open 2 1 Job Reference(optional) A0272866 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:23 2014 Page 1 ID:sf8?Y395JXmOwKJyJLviMGyspll-bPLPFkNOx2S5PeXsAL2Gp8RwhJfJPRSke0jm5vzvW96 0-0-0 1-0-0 1-0-0 4.00 F12 Scale=1:10.0 2x4 11 3 1 T1 W1 B1 5 2x4 11 0-0-0 1.0-0 1-0-0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.04 Vert(LL) -0.00 5 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.05 Vert(TL) -0.00 5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:5 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=8/Mechanical,2=29/Mechanical,5=3110-3-2 (min.0-1-8) Max Horz5=25(LC 8) Max Uplift4=-14(LC 8),2=-59(LC 8) Max Grav4=14(LC 3),2=29(LC 1),5=34(LC 21) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES 1)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Extedor(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5)Refer to girder(s)for truss to truss connections. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 14 lb uplift at joint 4 and 59 lb uplift at joint 2. 7)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I runs r A0272 9 uss ype y 86 57236R CJS Jack-Open 8 1 Job Reference o tional Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 Welk Industries,Inc.Tue Jan 14 08:1224 2014 Page 1 ID:sf8?Y395JXmOwKJyJLvjMGyspll-3cvoS4N1 iMby0o62k2ZVML_zyjm8tCtt2TKeLzvW95 0-0-0 40 0 4-0-0 1� 5 0 0 7.00 12 Scale=1:14.7 4x4 3 T2 4.00 F12 1.5x4 II 2 v T1 `� a W2 1 W1 B1 ll 4 p• 6 2x4= 1.5x4 11 7 1.5x4 II 2-0-0 3-0-0 2-4-0 2-4-0 1-8-0 4 1 1-0.0 0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.52 Vert(LL) -0.01 6-7 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.67 Vert(TL) 0.02 6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.10 Horz(TL) 0.08 4 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:19 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x6 SP No.2*Except* MiTek recommends that Stabilizers and required cross W2:2x4 SP No.3 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=34/Mechanical,5=-10/Mechanical,7=431/0-8-0 (min.0-1-8) Max Horz 7=171(LC 12) Max Uplift4=-52(LC 12),5=-110(LC 9),7=-574(LC 8) Max Grav4=48(LC 21),5=7(LC 10),7=431(LC 1) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-331/165 BOT CHORD 1-7—168/346 WEBS 2-7=342/762 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vu1t=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;porch left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on,the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 52 lb uplift at joint 4,110 lb uplift at joint 5 and 574 lb uplift at joint 7. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job russ I russ I ype y 57236R D01G Half Hip Girder 1 1 Job Reference(Optional) A0272870 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:25 2014 Pa 1 ID:sf8?Y395JXmOwKJyJLvjMGyspll-XoTAgOOfrgjpeyhFHm4kuZW6Q7CItCx1 NCtAnzvW94 0 0 0 2-4-0 1" 7-0-0 11-3-10 775 7...1q15.8-0 2-4-0 1-8 0 3-0-0 4-3-10 4-3-10 o-0 12 Scale=127.9 4x4 �&4= 1.5x4 II 7.00 12 6 3 Li 4.00 F12 44% T2 3 2x4 11 m 2 T1 1 W 18 1 m B, Ic? 6 s 9 8 3x4= 10 5x6= 3x8= 46 11 7 2-0.0 13-8-12 0 0 0 2-4-0 7-0-0 l 7-4 15-8-12 2-4-0 4-8.0 8-7-4 0 1r8 Plate Offsets(X,Y): f8:0-3-0,0-1-81,fl0:0-2-4,0-2-121 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.60 Vert(LL) 0.32 8-9 >492 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.59 Vert(TL) -0.61 8-9 >257 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.58 Horz(TL) -0.02 8 n/a n/a BCDL 10.0 Code FBC2010(TP12007 (Matrix-M) Weight:82 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-11-1 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3'Except* MiTek recommends that Stabilizers and required cross W1:2x8 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 10=918/0-8-0 (min.0-1-8),8=791/Mechanical Max Horz 10=284(LC 8) Max Upliftl 0=-1 072(LC 8),8=-1103(LC 5) Max Grav 10=1004(LC 43),8=1082(LC 40) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=329/246,3-4=-1338/1288,4-14=-1171/1195,5-14=-1171/1195 BOT CHORD 1-10—197/326,9-10=1056/983,9-17—964/833,17-18=964/833,18-19=964/833, 19-20—964/833,8-20=-964/833 WEBS 2-10=-214/324,3-10—1341/1317,3-9=408/452,4-9=157/374,5-9=337/543, 5-8=-1064/1230 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Refer to girder(s)for truss to truss connections. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1072 lb uplift at joint 10 and 1103 lb uplift at joint 8. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 10)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)321 lb down and 397 lb up at 7-0-0,209 lb down and 177 lb up at 9-1-1,209 lb down and 177 lb up at 11-1-1,and 209 lb down and 177 lb up at 13-1-1,and 209 lb down and 177 lb up at 15-1-1 on top chord,and 319 lb down and 301 lb up at 7-0-0,109 lb down and 82 lb up at 9-1-1, 109 lb down and 82 lb up at 11-1-1,and 109 lb down and 82 lb up at 13-1-1,and.109 lb down and 82 lb up at 15-1-1 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=-72,3-4=72,4-6=-72,7-11=-20 Julius Lee,P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach,FL 33435 o russ russ ype ry y 57236R D01 G Half Hip Girder 1 1 Job Reference(optional) A0272870 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.50D s Nov 26 2013 Print 7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:26 2014 Page 2 I D:sf8?Y395JXmOwKJyJLvjMGyspl l-0_1 YtmPHEzrgG5GRrTbzRm3HAWXXcfBAKMyoiEzvW93 LOAD CASE(S) Standard Concentrated Loads(Ib) Vert:4=-97(B)9=77(B)5=-34(B)14=-34(B)15=34(B)16=34(B)17=32(B)18=-32(B)19=32(B)20=-32(B) Julius Lee,P.E.#34869 1109 Coastal Bay Boynton Beach,FL 33435 Job Iruss russ ype ty y A0272871 57236R ID02 Half Hip 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:26 2014 Pa�gge� 1 ID:sf8?Y395JXmOwKJyJLvjMGyspl1-0_1 YtmPHEzrgG5GRrTbzRm3Gh WarcjgAKMyQiEzvW93 0-0-0 2-4-0 4-0o 9-0-0 15-7-4 15-&0 2-4-0 1-8-0 5-0-0 6.7-4 0-0r12 Scale=130.5 5x10 MT20H 1.5x4 II 4 5 7.00 12 T3 4.00 F12 4x6 or 3 1.5x4 II &48 2 T1 1 W1 rfjm LJIcy e e o e e 8 7 3x4= 9 3x6= 3x4= 46 11 6 2-0-0 1 13-8-12 0-0-0 2-4-0 2-4-0 6 S-0 9-0-0 6-7-4 1`71 15-8-12 Plate Offsets(X,Y): r4:0-6-0,Edgel,f7:0-3-0,0-1-81 8 LOADING(psf) SPACING 2-0-0 CSI DEFL in floc) I/dell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.69 Vert(LL) -0.05 7-8 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.44 Vert(TL) -0.12 7-8 >999 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.35 Horz(TL) 0.02 7 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:84 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2'Except* TOP CHORD Structural wood sheathing directly applied or 4-4-15 oc purlins. T3:2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 4-7 WEBS 2x4 SP No.3*Except* MiTek recommends that Stabilizers and required cross WI:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation quide. REACTIONS (lb/size) 9=837/0-8-0 (min.0-1-8),7=590/Mechanical Max Horz9=391(LC 12) Max Uplift9=-530(LC 12),7=-461(LC 9) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=716/209,2-3=-578/196,3-4=-833/544 BOT CHORD 1-9=-191/705,8-9=-740/1056,7-8=-656/782 WEBS 2-9—146/418,3-9=-1254/1191,3-8=325/267,4-8=0/285,4-7—951/797,5-7=-259/377 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)Plates checked for a plus or minus 0 degree rotation about its center. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8)Refer to girder(s)for truss to truss connections. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 530 lb uplift at joint 9 and 461 lb uplift at joint 7. 10)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Jou I runs I toss YPe tY Y A0 772872 57236R D03 Half Hip 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print 7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:27 2014 Page 1 I D:sf8?Y395JXmOwKJyJLvj MGyspl l-U Bbw550v?HzXtFrdPA6C_cU46wweL2jKZOh_Fgzv W92 0 0-0 2 4-0 2-4-0 1-8-0 4-0-0 2-1010 6.10-10 41 5 11-0-0 4-7-4 15-7r1215-8-0 48= 1.5x4 II Scale=1:34.2 5 6 T3 7.00 F12 3x4\\ 4 4.00 12 4x4 5 3x6% 3 2 4 1 1 W1 B1 1 F O 0 10 9 8 11 7 3x4= 1.5x4 II 3x8= 3x4= 4x6 II 0- 0 2-0-0 13-8-12 8 15-8-12 Plate Offsets MY): [4:0-2-0,0-1-01,[5:0-5-8,0-2-01,[8:0-3-0,0-1-81 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.46 Vert(LL) -0.06 9-10 >999 360 MT20 2441190 TCDL 16.0 Lumber Increase 1.25 BC 0.40 Vert(TL) -0.16 9-10 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.88 Horz(TL) 0.02 8 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:94 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-9-7 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3*Except* MiTek recommends that Stabilizers and required cross Wl:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 11=837/0-8-0 (min.0-1-8),8=590/Mechanical Max Horz 11=498(LC 12) Max Upliftl 1=-517(LC 12),8—458(LC 9) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2—611/224,2-3=-742/204,3-4—902/329,4-5=-629/383 BOT CHORD 1-11=-199/612,10-11=-348/334,9-10=-878/1120,8-9=-479/585 WEBS 2-11=-1 092/964,2-10=-612/994,3-10=-387/251,5-9=-227/535,5-8=-942/771,4-9—686/500,4-10_93/347, 6-8=-176/257 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MW FRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Refer to girder(s)for truss to truss connections. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 517 lb uplift at joint 11 and 458 lb uplift at joint 8. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E.#34869 1109 Coastal Bay Boynton Beach,FL 33435 Job russ I russ I ype uty Fly 57236R DT1 Common Supported Gable 1 1 A0272873 Job Reference o tional At ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:28 2014 Page 1 I D:sf8?Y395JXmOwKJyJLvj MGysp 11-yN 911 RQXmb5OVPQgzudR W B8kBKLN4h5Tog RXn6zvW 91 0.0-0 40 0 4-0-0 4-0-08-0-0 44= Scale=124.3 3 7.00 F12 1.5x4 II 1.5x4 II 4 2T1 1 1.5 x4 II 1.5x4 II 5 T T1 T1 W1 W1 ab B1 10 9 8 7 6 2x4 I I 2x4 11 1.5x4 11 1.5x4 11 1.5x4 [I 0-0-0 &� 6-0-0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.18 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.12 Vert(TL) n/a n/a 999 BCLL 0.0 Rep Stresslncr YES WB 0.10 Horz(TL) 0.00 6 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:42 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS All bearings 8-0-0. (lb)- Max Horz 10=-152(LC 8) Max Uplift All uplift 100 lb or less at joint(s)except 10=116(LC 13),6=-113(LC 12),9=-256(LC 12), 7=254(LC 13) Max Grav All reactions 250 lb or less at joint(s)10,6,8 except 9=324(LC 21),7=319(LC 22) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-253/288,3-4=253/288 WEBS 2-9=357/348,4-7=-357/348 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)Gable requires continuous bottom chord bearing. 6)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web). 7)Gable studs spaced at 2-0-0 oc. 8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 116 lb uplift at joint 10,113 lb uplift at joint 6,256 Ito uplift at joint 9 and 254 lb uplift at joint 7. 11)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job russ I russ I ype Qty y A0272874 57236R DT2 Common 2 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:28 2014 Page 1 I D:sf8?Y395JXmOwKJyJLvj MGyspl l-yN911 RQXmb5OVPQgzudR WBBcNKES4h uTog RXn6zvW 91 G-0-0 4-0-0 4-0-0 4 0-0 8-0-0 44= Scale=124.6 2 7.00 12 T1 T1 3x8 MT20H I I 3x8 MT20H I I 3 1 W2 cp B1 e 6. 5 6 s. 6 1.5x4 II 4 5x10 MT20H I I 5x10 MT20H I I 0-0.0 40 0 4-0-0 40 0 8-0-0 Plate Offsets(X,Y): rl:0-4-12,Edge],[3:0-4-12,Edge],f4:0-3-8,Edge) LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.68 Vert(LL) 0.24 5 >393 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.56 Vert(TL) 0.21 5 >443 240 MT20H 187/143 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(TL) -0.01 4 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Mat(x-M) Weight:35 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.2`Except* BOT CHORD Rigid ceiling directly applied or 7-6-14 oc bracing. W2:2x4 SP No.3 MTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 6=35510-8-0 (min.0-1-8),4=355/0-8-0 (min.0-1-8) Max Horz 6—152(LC 8) Max Uplift6=-297(LC 9),4=297(LC 8) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-436/789,2-3=-436/789,1-6—489/706,3-4—489/706 BOT CHORD 5-6=481/219,4-5=481/219 WEBS 2-5=421/84 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;porch left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)All plates are MT20 plates unless otherwise indicated. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Provide mechanical connection(by others)of truss to bearing plate capable of Withstanding 297 lb uplift at joint 6 and 297 lb uplift at joint 4. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 ocuss cuss ype y ��72875 57236R �'101G Roof Special Girder 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MIT&Industries,Inc.Tue Jan 14 013:12:30 2014 Page 1 IDsf8?Y395JXmOwKJyJLvjMGysp11-umH3j7SnHCL61qaC4JgvbcEuG8g8YOgmFzwer?zvW9? 0-0 o 2-4-0 -0 4 0.0 7-0-0 12-4-0 16-0-0 19-8-0 25-0-0 28-0 0 29-8-0 32.0-0 2-4-0 1-8 3-0-0 5.4-0 3-8-0 3-6-0 5-4-0 3-0-0 1-8-0 2-4-0 Scale=1:58.4 2x4 11 7.00 P2 48= 2x4 I 3x6- 3x8 OH= 4x- 8= 4.00 12 5 6 8 4x4 4x4 2x4 II 3 10 2x4 11 2 11Ch n 1 12 LLJ to 19 18 17 16 15 14 13 �1_ 2-0-0 i 4xa= 1ds4ff= RY12- FY12 A8-0-0 RY4= 4YFi 2-0-0 4 4-=� f 3xEs M!20Fr- 3X4= i 28-0-0 0-0 0 2-4-0 7-0 0 12 4 0 19-8-0 25-0-0 29 8 0 32-0-0 2-4-0 4-8-0 5-4-0 7-4-0 5-4-0 4-8-0 2-4-0 Plate Offsets(X,Y): [4:0'5-8,0-2-01,[9:0-5-8,0'2-01,[13:0-2-4,0-2-01,[15:0-6-0,0-3-01,[17:0-6-0,0-3-01,[19:0-2-4,0-2-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.91 Vert(LL) 0.46 15-17 >454 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.93 Vert(TL) 0.39 15-17 >537 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr NO WB 0.86 Horz(TL) -0.03 13 n/a n/a BCDL 10.0 Code FBC201 OrFP12007 (Matrix-M) Weight:175 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-11-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 3-8-5 oc bracing. WEBS 2x4 SP No.3'Except* MTek recommends that Stabilizers and required cross W1,W6:2x8 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 19=477/0-8-0 (min.0-1-8),17=1925/0-8-0 (min.0-2-10),13=998/0-8-0 (min.0-1-8) Max Horz 19=104(LC 8) Max Upliftl9=394(LC 8),17-3467(LC 5),13=1691(LC 5) Max Grav19=498(LC 41),17=2226(LC 43),13=1002(LC 42) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-284/204,3-4=-581/135,4-26=-1043/675,26-27=-1043/675,5-27=-1043/675, 5-28=1043/675,28-29-1043/675,6-29_1043/675,6-30=1032/2156,7-30=-1032/2156, 7-8=103212156,8-31=-1 032/2156,31-32=-1032/2156,9-32=-1032/2156, 9-10=-1122/2084 BOT CHORD 1-19=-163/293,18-19=130/623,18-33-89/652,33-34=89/652,17-34=89/652, 17-35=-553/411,35-36=-553/411,16-36=-553/411,16-37=-553/411,37-38=553/411, 15-38=553/411,15-39=1681/987,39-40=-1681/987,14-40=1681/987, 13-14-1333/750 WEBS 2-19=180/278,3-19=-537/259,3-18=-136/258,4-18=265/526,4-17=-1117/1286, 5-17=-507/673,6-17=-1315/2393,6-15=-1909/947,8-15=-493/647,9-15=-452/325, 9-14=-426/201,10-14=-534/325,10-13=-1116/1846,11-13=-203/308 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed;porch right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)Plate(s)at joint(s)1,3,4,7,9,10,12,2,19,18,17,5,6,8,15,14,13 and 11 checked for a plus or minus 0 degree rotation about its center. 6)Plate(s)at joint(s)16 checked for a plus or minus 5 degree rotation about its center. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 394 lb uplift at joint 19,3467 lb uplift at joint 17 and 1691 lb uplift at joint 13. 10)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. Julius Lee,P.E. #34869 Continued on page 2 1109 Coastal Bay Boynton Beach,FL 33435 Job Iruss russ Type ty y 57236R �EWG Roof Special Girder 1 1 Job Reference(optional) A0272875 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:30 2014 Pa�9g��e 2 ID:sf8?Y395JXmGwKJyJLvjMGyspl l-umH3j7SnHCL6kjaC4JgvbcEuG8g8YOgmFzwer?zvW9? NOTES 11)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)209 lb down and 177 lb up at 7-0-0,209 lb down and 177 lb up at 9-0-12,209 lb down and 177 lb up at 11-0-12,209 lb down and 177 lb up at 13-0-12,209 lb down and 177 lb up at 15-0-12,209 lb down and 177 lb up at 16-11-4, 209 lb down and 177 lb up at 18-11-4,209 lb down and 177 lb up at 20-11-4,and 209 lb down and 177 lb up at 22-11-4,and 209 lb down and 177 lb up at 25-0-0 on top chord,and 319 lb down and 301 lb up at 7-0-0,109 lb down and 82 lb up at 9-0-12,109 lb down and 82 lb up at 11-0-12,88 lb down and 199 lb up at 13-0-12,88 lb down and 199 lb up at 15-0-12,88 lb down and 199 lb up at 16-11-4,88 lb down and 199 lb up at 18-11-4,88 lb down and 199 lb up at 20-11-4,and 88 lb down and 199 lb up at 22-11-4,and 361 lb down and 418 lb up at 24-11-4 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 12)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=-72,3-4=72,4-9=72,9-10=72,10-12=72,20-23=-20 Concentrated Loads(lb) Vert:4=-34(F)7=-34(F)9=-34(F)18=77(F)14=75(F)26=34(F)27=34(F)28=34(F)29—34(F)30=34(F)31=34(F)32=-34(F)33=-32(F)34=-32(F)35—34(F) 36=34(F)37=34(F)38=34(F)39=34(F)40=-34(F) Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,PL 33435 Job I russ I russ I ype Qty Ply A0272876 57236R E02 Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:31 2014 Page 1 IDsf8?Y395JXmOwKJyJLvjMGyspl1-MygRxTTQ2WTzMt9OeOB88gm2EXATHsGvUdfBORzvW9_ 0 0 0 2-4-0 2t4 -8 0 0-0 5 0 0 9-0-0 3-0 0 12A-0 7-4-0 19-8-0 3.4-0 23 0 O 540 28-" 2 �2-4-0 3240 Scale=1:58.4 48= 7.00 F12 1.5x4 II 3x6= 4813 = 4 5 6 7 4.00 F12 46 6 46 1.5x411 3 8 1.5x411 2 9 v 1 10 I CP o 17 16 15 14 13 12 11 2-0 0 S_6_ 10-0-0 = 4 _ 3x8 NMOH= 18-0-0 = 2-0-O;x4 3x4 = = ` — — i 28-0-0 i 0-0-0 2-4-0 9-" 12-4-0 7-4-0 23-0-0 29�6-0 3240 2.4-0 6-8.0 3-4-0 7-4-0 3-4-0 6.8.0 2-4-0 Plate Offsets(X,Y): [4:0-5-8,0-2-0),[7:0-5-8,0-2-01,fl5:0-4-0,0-3-0] LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.96 Vert(LL) 0.47 13-15 >441 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.92 Vert(TL) 0.42 13-15 >500 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.78 Horz(TL) -0.04 11 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight:176 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3*Except* WEBS 1 Row at midpt 6-15 Wl:2x6 SP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 17=544/0-8-0 (min.0-1-8),15=1464/0-8-0 (min.0-2-3),11=937/0-8-0 (min.0-1-8) Max Horz 17=-166(LC 10) Max Upliftl7—399(LC 12),15=1602(LC 9),11—1057(LC 9) Max Grav17=558(LC 25),15=1464(LC 1),11=944(LC 26) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-596/207,2-3=489/208,3-4=-275/100,4-5=332/269,5-6=332/269, 6-7=-798/1906,7-8=-949/1967,9-1 0=-1 87/251 BOT CHORD 1-1 7=-1 92/600,16-17=-244/617,15-16=-98/612,14-15=-1348/618,13-14=-1348/618, 12-13=1326/600,11-12=1357/810 WEBS 2-17—110/318,3-17=745/527,3-16=497/412,4-16=45/262,4-15=-774/465, 5-15=-554/776,6-15=-1243/2620,6-13=-613/215,7-13=-251/102,7-12=-557/168, 8-12=-307/242,8-11=-1 404/2175 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;VuIt=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;porch right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)Plate(s)at joint(s)1,3,4,7,8,10,2,17,16,15,5,6,13,12,11 and 9 checked for a plus or minus 0 degree rotation about its center. 6)Plate(s)at joint(s)14 checked for a plus or minus 5 degree rotation about its center. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 399 lb uplift at joint 17,1602 lb uplift at joint 15 and 1057 lb uplift at joint 11. 10)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. 934869 1109 Coastal Bay Boynton Beach,FL 33435 Job I cuss I russ I ype city ly 57236R E03 Roof Special 1 a0272877 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:32 2014 Page 1 ID:sfB?Y395JXm0wKJyJLvjMGyspl l-g8Op8pU2ppbp_OjbCkiNh i JG WxU20lc3iHPlvtzvW8z 0 0 0 2 4 0 4 0 0 11-0-0 12-4-0 19-8-0 21-0-0 28-10 2910 32-0l 2-4-0 1.8-0 7-0-0 .1-4-0. 7-4-0 1 4 0 7-0.0 1-8 0 2-4-0 Scale=1:58.4 5xl0 MT20H= 3x4= 5x10 MT20H= 3x6 11 7.00 F12 4 5 6 7 4.00 12 VW7 5x6\\ 3x6 3 8 5x6//3x6 7 2 9 1 10 Io 19 18 17 16 15 14 13 12 11 42*0 1.5x4 11 10-0.0 4x4=5x8= 3x8 MT20H= 3x4= 3x4=3x6 I I 3x4= 3x4= 2-0 0 { 28-0-0 0 0-0 2-4-0 4 0 0 11-0- -:" 1&8-0 21-0-0 28-0-0 �gS-0 32-0-0 2-4-0 1-8-0 , 7-0-0 1 4 0, 7-4-0 1-4-0, 7-0-0 1-8-0 , 2-4- Plate Offsets(X,Y): f3:0-2-4,0-2-81,f4:0-8-0,0-2-41,f6:0-1-12,0-1-81,f7:0-8-0,0-2-41,f8:0-2-0,0-2-01,116:0-4-0,0-3-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.80 Vert(LL) 0.43 12-13 >488 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.97 Vert(TL) 0.38 12-13 >551 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.84 Horz(TL) -0.03 11 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:208 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2*Except* TOP CHORD Structural wood sheathing directly applied or 4-11-10 oc purlins. T2:2x6 SP No.2,T3:2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 6-16 WEBS 2x4 SP No.3*Except* MiTek recommends that Stabilizers and required cross WI:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 19=546/0-8-0 (min.0-1-8),16=1460/0-8-0 (min.0-2-6),11=93810-8-0 (min.0-1-8) Max Horz 19=245(LC 10) Max Upliftl9=-418(LC 12),16=-1491(LC 9),11=-1009(LC 8) Max Grav 1 9=560(LC 25),16=1460(LC 1),11=946(LC 26) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-543/259,2-3=514/161,3-4=-378/277,6-7=846/1687,7-8=938/1678, 8-9=915/1840,9-10=-558/234 BOT CHORD 1-1 9=-240/559,18-19=-300/559,17-18=-292/786,16-17—277/770,15-16=-952/496, 15-26—952/496,26-27=952/496,14-27=952/496,13-14=-1005/511,12-13—1669/926, 11-12=217/564,10-11=-217/564 WEBS 2-19=-725/539,4-17=51/441,4-16—884/420,5-16—500/703,6-16=-1173/2192, 6-14=-638/297,7-14=377/175,7-13=-618/184,9-11—1118/2442,3-18=344/353, 3-17=-808/561,2-18=376/807,8-12=734/669,8-13=-492/695,9-12=2584/1278 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;porch right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)Plates checked for a plus or minus 0 degree rotation about its center. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)•This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 418 lb uplift at joint 19,1491 lb uplift at joint 16 and 1009 lb uplift at joint 11. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. 934869 1109 Coastal Bay Boynton Beach,FL 33435 Job I cuss I russ I ype ty y �2:87]8 57236R E04 Roof Special 1 1 Job Reference(optional) At ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:33 2014 Pag9e� 1 p p ID:sf8?Y395JXmOwKJyJLvjMGyspl1-IKyBL9Uga7jgbAlnIRDcDFsTELvKlkoCxx8lR;Olw8y 0-0 0 40 0 4-0-0 �� 10.0-0 2-40120 Op 3 3-0-0 16-0-0 3_" 19�19-82-0- 22 0 O 4-0 6-0-0 28-0-0 40 0 32-0-0 Scale=1:59.5 3x8 MT20H% 3x8 MT20H 1.5x4 11 3x4= 8 1.5x4 11 5 6 7 9 7.00 F12 3x10\\ 3x10 4 10 4.00 F12 4x6% 4x6 3x6 7::- 3 4 5 11 3x6 2 W�2 cc[ 1 cJ 13 Io 20 19 18 17 16 15 14 3x6 11 3x8= 5x8= 3x8 MT20H= 5x8— 3x8=3x6 I I 3x4= 10-0-0 —18-0-0 2-0-0 i 28-0-0 1 0 0-0 2-4- 0 2-41 8 041 8-0-0 14412-4-0 7-4-01442040 6 ao 28.0•?9 0 ,-02-0 032-0.0 Plate Offsets(X,Y): [3:0-3-0,0-2-4),[4:0-3-8,Edgel,[6:0-3-1,Edgel,f8:0-3-1,Edge],[10:0-3-8,Edgel,[11:00--3-0,0-2-41,[16:0-4-0,0-3-Of,[18:0-4-0.0-3-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.67 Vert(LL) 0.56 15-16 >373 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.64 Vert(TL) 0.49 15-16 >427 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.91 Horz(TL) 0.01 14 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:190 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2*Except* TOP CHORD Structural wood sheathing directly applied or 5-5-2 oc purlins. T2:2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: BOT CHORD 2x4 SP M 30 10-0-0 oc bracing:16-18 WEBS 2x4 SP No.3'Except* 5-10-7 oc bracing:15-16. WI:2x6 SP No.2 WEBS 1 Row at midpt 7-16,7-18 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 18=1378/0-8-0 (min.0-2-9),20=598/0-8-0 (min.0-1-8),14=968/0-8-0 (min.0-1-8) Max Horz20=324(LC 8) Max Upliftl8=-1202(LC 9),20=404(LC 12),14=-999(LC 8) Max Grav 18=1378(LC 1),20=630(LC 25),14=975(LC 26) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-507/246,2-3=-468/114,3-4=865/411,8-9—762/1405,9-10=-985/1769, 10-11=-1354/2467,11-12=-919/1889,12-13=-558/218,7-8=-793/1524 BOT CHORD 1-20=228/527,19-20=370/588,18-19=169/551,18-27—192/319,17-27—192/319, 17-28=192/319,16-28=192/319,1 5-1 6=11331739,14-15=-201/563,13-14=201/563 WEBS 7-16=-1420/690,10-16=-945/1025,10-15=-786/345,11-15—891/1057,7-18=-1075/1876, 4-18=948/759,4-19=-399/846,3-19=-796/616,2-19=-228l749,2-20=-723/406, 12-15=-2624/1249,12-14=-1136/2516,5-18=-272/337,9-16=-703/278 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;porch right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)Plates checked for a plus or minus 0 degree rotation about its center. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1202 lb uplift at joint 18,404 lb uplift at joint 20 and 999 lb uplift at joint 14. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ russ Ype tY Y A0272879 57236R �IE04A Roof Special 1 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:33 2014 Pa�gge 1 I D sf8?Y395JXmOwKJyJLvj MGyspl l-I KyBL9Uga7jgbA1 n I RDcDFsRPLv?In KCxx8l R;Olw8y 0-0-0 4-0-0 4-0-0 6-0-0 10-0-0 3-a0 13 0 0 3-0-0 16 0-0 3-0_0 19-0-0 3_G_o 22 0 O 6-0-0 28-0-0 4-0-0 32-0-0 Scale=1:59.5 5x10 MT20H i 5x10 MT20H� 3x4= 5 6 7 7.00 F12 3x6\\ 3x6 4 8 IVr IV, 4.00 12 46 6 46� n 3x6% 3 4 19 0 20 5 9 3x6 2 1.5x4 11 1.5x4 11 yyi 0 1 11 Io 18 17 16 15 14 13 12 2-0-00 3x6 3xR- 3x4= 3xa} �1H= 3x4= 3xR=3x6,I 12-0 03x�_ sx4— 0 0 0 2tO 4-0-0 12-0-0 20-0-0 28-0- 8 2-4-0 -0 32-0-0 2-4-0 1-8-0 8-0-0 8-0-0 8-0-0 Plate Offsets(X,Y): [3:0-2-8,0-2-4],[4:0-1-12,0-1-4],[5:0-7-0,0-2-4],[7:0-7-0,0-2-4],[8:0-1-12,0-1-4],[9:0-2-8,0-2-4],[13:0-2-0,0-1-8],[17:0-2-8,0-1-8],[19:0-1-12,0-0-12], [20:0-1-12,0-0-12] LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.79 Vert(LL) 0.34 14-16 >956 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.66 Vert(TL) -0.51 14-16 >639 240 MT20H 1871143 BCLL 0.0 ' Rep Stress Incr YES WB 0.74 Horz(TL) 0.08 12 .n/a n/a BCDL 10.0 Code FBC20101TPI2007 (Matrix-M) Weight:186 lb FT=0 LUMBER BRACING TOP CHORD 2x4 SP No.2'Except* TOP CHORD Structural wood sheathing directly applied or 2-2-1 oc purlins. T2:2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-2-13 oc bracing. BOT CHORD 2x4 SP No.2 JOINTS 1 Brace at Jt(s):19,20 WEBS 2x4 SP No.3*Except* MiTek recommends that Stabilizers and required cross W6:2x4 SP M 30,W1:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 18=1472/0-8-0 (min.0-2-11),12=147210-8-0 (min.0-2-11) Max Horz 18=-324(LC 8) Max Upliftl8=-952(LC 12),12—952(LC 13) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-497/210,2-3=-2031/1145,3-4=-2642/1689,4-5=-2652/2027,7-8=-2652/2027, 8-9=2642/1689,9-10—2031/1145,10-11—497/210,5-6—2341/1862,6-7=2341/1862 BOT CHORD 1-1 8=-1 90/514,17-18=-355/588,16-17=-1240/2115,16-27=936/1692,15-27—936/1692, 15-28=-936/1692,14-28=-936/1692,13-14=-1240/2115,12-13—190/514, 11-12=-190/514 WEBS 6-20=157/393,14-20=451/793,8-14=-701/613,8-13=-285/372,9-13=1239/992, 16-19=-451l793,6-19=-157/393,4-16=-701/613,4-17=-286/373,3-17—1239/992, 2-17=-1747/2499,2-18=2149/1706,10-13=1747/2499,10-12=2149/1706, 5-19=507/704,7-20=-507/704 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;VuIt=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MW FRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)All plates are MT20 plates unless otherwise indicated. 5)Plates checked for a plus or minus 0 degree rotation about its center. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 952 lb uplift at joint 18 and 952 lb uplift at joint 12. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 o russ cuss ype y y ' A0272880 57236R E05 Roof Special 2 1 Job Reference(optional) � Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:34 2014 Page 1 ID:sf8?Y395JXmOwKJyJLvjMGyspll-nXWZZWILRrXDKtzJ9krmSOekIF1 UEGMAbuszmzvW8x 0 0 0 40-0 40-0 6-0-0 10• -0 5.0-0 15( �gE o-q 17-0-0 5 a0 22-0-0 �� 28 0 0 0 32-0-0 Scale=1:59.5 46= 3xe 11 74x6= 5 6 T 7.00 F12 3x8\\ 3x8// 4 8 W 6 4.00 F12 .0 46 4x6 3x6% 3 4 5 9 3x6 2 W>10 .- 1 11 Io 18 17 16 15 14 13 12 3x6 11 3x8— 3x4= 3x6= 3x4= 3x8—_3x6 11 3x4= 4 Z_:0-o r — 28-0-0 i 2-0-0 1 0-0-0 2 0 2-4-0�40-° 8-0-012°° 8-0-0 20-0-0 8-" 28- 1-8 B-02 4 032 i0-0 Plate Offsets(X,Y): (3:0-2-12,0-2-01,(4:0-3-8,Edgel,(5:0-4-4,0-1-01,I6:0-4-12,0-1-81,i7:0-4-4,0-1-01,f8:0-3-8,Edgel,f9:0-2-12,0-2-01,(13:0-1-12,0-1-81,(17:0 2-12,0 1-81 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.69 Vert(LL) -0.18 14-16 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.33 14-16 >980 240 BCLL 0.0 ' Rep Stress Incr YES WE 0.76 Horz(TL) 0.09 12 n/a n/a BCDL 10.0 Code FBC20I OfTP12007 (Matrix-M) Weight:178 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2`Except' TOP CHORD Structural wood sheathing directly applied or 3-5-10 oc purlins. T2:2x4 SP M 30,T3:2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 5-2-7 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 6-14,6-16 WEBS 2x4 SP No.3'Except' MTek recommends that Stabilizers and required cross WI:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 18=1472/0-8-0 (min.0-2-13),12=1472/0-8-0 (min.0-2-13) Max Horz 18=-401(LC 10) Max Upliftl8=980(LC 12),12—980(LC 13) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-492/208,2-3=-2118/1103,3-4=-2684/1600,4-5=-2915/2058,7-8=-2915/2058, 8-9=2684/1600,9-10=-2118/1103,10-11=492/208,5-6=-2470/1876,6-7=2470/1876 BOT CHORD 1-18—178/507,17-18=-427/668,16-17=-1252/2329,16-25—602/1472,15-25—602/1472, 15-26=-602/1472,14-26=-602/1472,13-14=1252/2329,12-13=-178/507, 11-12—178/507 WEBS 6-14=-738/1147,8-14=-906/800,8-13=-370/341,9-13=-1158/900,6-16=-738/1147, 4-16=-906/800,4-17=-371/341,3-17=-1158/900,2-17=-1681/2565,2-18=-2248/1688, 10-13=1681/2565,10-12—2248/1688 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Provide adequate drainage to prevent water ponding. 4)Plate(s)at joint(s)1,3,5,7,9,11,14,6,8,16,4,2,17,18,10,13 and 12 checked for a plus or minus 0 degree rotation about its center. 5)Plate(s)at joint(s)15 checked for a plus or minus 5 degree rotation about its center. 6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 980 lb uplift at joint 18 and 980 lb uplift at joint 12. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I russ I ype y A0272881 57236R E06 Roof Special 3 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:35 2014 Page 1 1 D:sf8?Y395JXmOwKJyJL,4MGyspll-F14ymrWw6kzOrUSAtsF4lgxpb9bBDgKVPFdPWCzvW8w 0 0 0 ¢� 4-" 6-0-0 10-0-0 6-0-0 16-0-0 6-0-0 6-0-0 6-0-028-0-0 4-0-032-0-0 Scale=1:58.4 4x6= 5 7.00 12 3x8\\ 3x8 4 6 W 6 4.00 12 4x6 4x6 3x6 5-� 3 4 5 7 3x6 2N1 W? 1 IV 9 I,6 16 15 14 13 12 Li 11 10 3x4= 3x6 II 3x8— 3x4= 3x6= 3x4= 3x8=3x6 II 3x4= — — 2-0-0 i 211-0-0 i 2-0-0 0-ao 2 4 0 2-4-0 0 0 &� 12-0-0 8-0-0 2o-0-0 &ao 26.0-(�$?09 8 0 2_"32-0-0 Plate Offsets(X,Y): i4:0-3-8,Edgel,i5:0-3-0,0-1-121,[6:0-3-8,Edge],if 1:0-1-12,0-1-81,i15:0-2-12,0-1-81 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TIC 0.68 Vert(LL) -0.19 12-14 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.34 12-14 >972 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.78 Horz(TL) 0.09 10 n/a n/a BCDL 10.0 Code FBC2010(rP12007 (Matrix-M) Weight:178 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2'Except' TOP CHORD Structural wood sheathing directly applied or 3-5-14 oc purlins. T2:2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-2-6 oc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 5-12,5-14 WEBS 2x4 SP No.3*Except* MiTek recommends that Stabilizers and required cross Wl:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 16=1472/0-8-0 (min.0-2-14),1 0=1 472/0-8-0 (min.0-2-14) Max Horz 16=441(LC 8) Max Uplifts 6=-992(LC 12),10=992(LC 13) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-490/207,2-3=-2164/1085,3-4=2714/1560,4-5=-3039/2070,5-6=-3039/2070, 6-7=2714/1560,7-8=2164/1085,8-9=-490/207 BOT CHORD 1-1 6=-1 73/505,15-16=-463/708,14-15=-1256/2431,14-23=-570/1549,13-23=570/1549, 13-24=-570/1549,12-24=-570/1549,11-12=-1256/2431,10-11=-173/505, 9-10=173/505 WEBS 5-12=-800/1212,6-12=-981/873,6-11=-423/379,7-11=-1127/858,5-14=-800/1212, 4-14=-981/873,4-15=-424/379,3-15=-1127/858,2-15=-1651/2605,2-16=-2301/1681, 8-11=1651/2605,8-10=-2301/1681 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Plate(s)at joint(s)1,3,5,7,9,12,6,14,4,2,15,16,8,11 and 10 checked for a plus or minus 0 degree rotation about its center. 4)Plate(s)at joint(s)13 checked for a plus or minus 5 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=1 O.Opsf. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 992 lb uplift at joint 16 and 992 lb uplift at joint 10. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 o russ russ ype 57236H E06A ROOF TRUSS �1271 Job Reference(optional) A0272882 At ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print 7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:36 2014 Page 1 ID sf8?Y395JXmOwKJyJLvjMGyspl l-jveK_AXYt25FSel MRZnJrtUxl Yyey6aedvNy2fzvWBv 00-0 4-0-0 8-1-5 11-11-8 16-0-0 20-0-8 23-10-10 28-0-0 32-0-0 4-0-0 416 3-10-3 4-0-8 4-0-8 3.10-2 41-5 4-0-0 Scale=1:58.4 4x4= 7 46 4x6 7.00 12 6 8 5 22 9 1.5x4 II 4 10 0 4.00 12 v 4x4: O 4x4 3x6% 3 11 3x6 2N1 4 5 W12 1 8-1-0 B2 Io 21 20 19 18 17 16 15 14 3x6 II 3x10= 5x10 MT20H WB= 5x10 MT20H WB= 3x10=3x6 11 i 240 28-0-0 2-0-0 i 0 0-0 2-4- 0 2�-8 0 7-11-8 1�W 1240 8 0 0 e 21348 7-11 8 28�-? 0 0 2 4 0 32.0.0 Plate Offsets(X,Y): (4:0-2-0,0-1-01,i5:0-1-8,0-1-81,i6:0-0-4,0-2-01,18:0-0-4,0-2-01,f9:0-1-8,0-1-81,11 0:0-2-0,0-1-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.89 Vert(LL) 0.63 18-20 >523 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.60 Vert(TL) -0.76 18-20 >433 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.84 Horz(TL) 0.08 14 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Attic -0.47 17-18 212 240 Weight:188 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2'Except* TOP CHORD Structural wood sheathing directly applied or 2-9-13 oc purlins. T2:2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. BOT CHORD 2x4 SP M 30'Except' JOINTS 1 Brace at Jt(s):22 B2:2x6 SP 2400F 2.0E MiTek recommends that Stabilizers and required cross WEBS 2x4 SP No.3'Except* bracing be installed during truss erection,in accordance with W1:2x6 SP No.2 Stabilizer Installation guide. REACTIONS (lb/size) 21=1 63410-8-0 (min.0-3-4),14=1634/0-8-0 (min.0-3-4) Max Horz 21=441(LC 8) Max Uplift2l=-847(LC 12),14—847(LC 13) Max Grav21=1 725(LC 2),14=1725(LC 2) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=-476/199,2-3=-2430/889,3-4—2852/1211,4-5=3565/1600,5-6=2942/1466, 8-9=2942/1466,9-10=-3565/1600,10-11=2852/1211,11-12—2430/889, 12-13=-476/199 BOT CHORD 1-21—157/490,20-21=421/687,19-20—1129/3076,18-19=1127/3079, 17-18=-696/2602,16-17=-1127/3079,15-16=-1129/3076,14-15=-157/490, 13-14=157/490 WEBS 10-17=716/609,10-15=-1024/545,11-15=-907/582,4-18=-716/609,4-20=-1024/545, 3-20=907/582,2-20=1388/2819,2-21=2570/1535,12-15=1388/2819, 12-14=2570/1535,5-18=-350/940,9-17=-350/940,6-22—3282/1675,8-22=-3282/1675 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)120.01b AC unit load placed on the top chord,16-0-0 from left end,supported at two points,5-0-0 apart. 4)All plates are MT20 plates unless otherwise indicated. 5)All plates are 3x4 MT20 unless otherwise indicated. 6)Plates checked for a plus or minus 0 degree rotation about its center. 7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9)Ceiling dead load(5.0 psf)on member(s).5-6,8-9,6-22,8-22; Wall dead load(S.Opsf)on member(s).5-18,9-17 10)Bottom chord live load(40.0 psf)and additional bottom chord dead load(0.0 psf)applied only to room.17-18 11)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 847 lb uplift at joint 21 and 847 lb uplift at joint 14. 12)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 13)ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. LOAD CASE(S) Standard Julius Lee,P.E. 934869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I russ I Ype tY Y 57236R E07 Roof Special 6 1 Job Reference(optional) A0272883 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:37 2014 Page 1 I D sf8?Y395JXmOwKJyJLvjMGyspl l-B6Ci B WXAeMD 64ocY_HH IIpY�p0506SyH4hZ8osZ6 Wa5zvW8u 0-0-0 40 0 8-11-13 14- f. 10 0-0 5.10-7 21-10-7 ��9 2 Q 8-021 8 0 8-0 32-0-0 4-0-0 4-11-13 5-4-3 1- 2-4-0 46= Scale=1:62.9 1.5x4 II 6 7.00 12 6 ILA 11 3x4 i VV8 7 4 4.00 12 4x6 1Ox14 1.5x4 11 3 *11 410 XV1 0 9 ,7 1 16 1 2 5X10= 15 1.5x4 110 jo Io 19 18 17 48= 13 12 11 1 3x4 5x6= 5x8= 1.5x4 II 1.5x4 II 3x6 II 3x4= = i 13-0-0 L � ii2-G-0 28-0-0 2-0-0 , 0-0-0 40 0 40 0 411-13 8-11-13 5-4-3 1 1-&0-0 5-10.7 21-10.7 �5 9 2741 0 1-S-S�2 E 32-0-0 Plate Offsets(X,Y): [4:0-1-12,0-1-81,[6:0-3-0,0-1-81,[7:0-3-8,0-0-121,[8:0-6-0,0-3-01,[9:0-4-12,0-2-01,[16:0-3-4,0-2-01,[18:0-4-0,0-2-41,[19:0-3-0,0-3-01,[20:0-2-0,0-0-01 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.85 Vert(LL) 0.28 13 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.65 Vert(TL) -0.50 15-16 >651 240 BCLL 0.0 Rep Stress Incr YES WB 0.88 Horz(TL) 0.28 11 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight:194 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2`Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. T2:2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-7-6 oc bracing. BOT CHORD 2x4 SP No.2`Except* WEBS 1 Row at midpt 8-15,6-16,6-15 B2,134:2x4 SP No.3,83:2x4 SP M 30 MiTek recommends that Stabilizers and required cross WEBS 2x4 SP No.3`Except` bracing be installed during truss erection,in accordance with W1:2x6 SP No.2,W12:2x4 SP No.2 Stabilizer Installation guide. REACTIONS (lb/size) 11=1 487/0-8-0 (min.0-2-14),19=1473/0-8-0 (min.0-2-13) Max Horz 19=-441(LC 8) Max Upliftl1=984(LC 13),19=-991(LC 12) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=571/168,2-3=-430/151,3-4=-3079/1879,4-5=-2964/1901,5-6=3061/2148, 6-7=-4114/2761,7-8=-3721/2205,8-9=-5420/3107 BOT CHORD 1-19=-141/568,18-19—1028/2080,5-16=532/492,16-27=632/1730,27-28=-632/1730, 15-28—632/1730,14-15=-2513/5234 WEBS 3-18=252/403,4-18=466/396,16-18—1264/2514,4-16=-579/506,7-15=-1199/1088, 8-15=-2243/1003,8-14=-326/292,9-11=-2180/1590,2-19=228/429,9-14=-2993/5002, 6-16=978/1473,6-15=1408/2053,3-19=-3023/2173 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL=10.Opsf. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 984 lb uplift at joint 11 and 991 lb uplift at joint 19. 7)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 o cuss russ ypeIW' --72 A0272884 57236R E08 GABLE Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:40 2014 Page 1 ID:sf8?Y395JXmOwKJyJLvjMGyspl l-bhtrpYa3xHchxFL7gPrF?jebiAHLuvREYXLABQzvW8r 0 0 0 2-4-0 40-0 8-1-7 12-2-2 15-7-4 22-2-0 29-11-4 2-4-0� 1 8-0 , 4-1-7 4.0-11 3-5-2 6-6-12 7-9.4 Scale=1:54.6 5x6 13-74 5 6 14-4-0 7.0011213 3x4\\ 4 2x4 11 4.00 F12 4x4 10x1J=ST2 2x4 II y�1 19 1 2x4 II 2x4 II 12x18 2 H= 6xl2\\ 3 T rs ST7 T4 ST9 W13 z 4CF 0 N B1 U U B 16 15 14 13 12 3x6 II 3x6 II 11 3x6 II 3x6 II 10 4x8= 4x8= 8x10= 3x8 11 5x10 MT20H= 10x14= 7x10 MT20H= 2-0-0 27-114 0-0-0 2t0 4" 2-2-pp 12-2 14 15-74 22-2-0 29-114 24-0 1-8-0 8-2-2 �12 3-4-6 6-6-12 7-9.4 Plate Offsets(X,Y): [2:0-2-4,0-1-8],14:0-2-0,0-1-0],[5:0-1-8,0-1-4],[7:0-3-8,0-4-8],[9:0-7-0,Edge],[10:0-4-11,0-7-11,[11:0-2-0,0-2-4],[12:0-5-12,0-1-8],[14:0-1'8,0-6-0], [17:0-3-4,0-1-01,[21:0-1-9,0-0-121,[23:0-3-9,0-1-81,[29:0-1-9,0-0-121 LOADING(psf) SPACING 1-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.98 Vert(LL) 0.76 11-12 >430 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.75 Vert(TL) -0.91 11-12 >361 240 MT20H 187/143 BCLL 0.0 ' Rep Stress Incr NO WB 0.91 Horz(TL) 0.07 10 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:478 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2*Except* TOP CHORD Structural wood sheathing directly applied or 3-11-11 oc purlins, T4:2x6 SP No.2 except end verticals. BOT CHORD 2x8 SP No.1'Except* BOT CHORD Rigid ceiling directly applied or 5-6-9 oc bracing. 132:2x8 SP 2400F 1.8E WEBS 2x4 SP No.3*Except* W13,W1:2x8 SP No.2,W6,W7:2x4 SP No.2,W12:2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS (lb/size) 10=3720/0-7-4 (min.0-1-9),16=2385/0-8-0 (min.0-1-8) Max Horz 16=522(LC 8) Max Upliftl 0=-4401(LC 5),16=-1926(LC 8) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=1157/1020,2-3_2217/1760,3-4=2517/2053,4-5—3758/3182,7-12=-2151/2238, 7-38=-9720/8522,38-39=-9720/8522,39-40=-9720/8522,40-41=9720/8522, 8-41=-9720/8522,8-42=9720/8522,42-43=9720/8522,43-44=9720/8522, 44-45=9720/8522,9-45=-9720/8522,9-10=-3468/4235 BOT CHORD 1-16=1382/1568,15-16_536/388,14-15=2992/3123,13-14—12029/13445, 1 2-1 3=-1 2029/1 3 445,1 2-46=-1 21 95/1 3 634,1 1-46=-1 2 1 9 5/1 3 634,10-11=-961/1003 WEBS 2-16=-1846/1471,2-15=-1808/2294,3-15=634/580,4-15—1297/1142,4-14=404/286, 5-14=-5343/6107,5-7=-5432/4818,7-1 4=-1 1 643/1 0 332,7-11=-4056/3860, 8-11—1038/907,9-11=-7778/8967 NOTES 1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows: Top chords connected as follows:2x4-1 row at 0-9-0 oc,2x6-2 rows staggered at 0-9-0 oc,2x8-2 rows staggered at 0-9-0 oc. Bottom chords connected as follows:2x8-2 rows staggered at 0-4-0 oc. Webs connected as follows:2x8-2 rows staggered at 0-9-0 oc,2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)Unbalanced roof live loads have been considered for this design. 4)Wind:ASCE 7-10;VuIt=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 5) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/fPI 1. 6)Provide adequate drainage to prevent water ponding. 7)All plates are MT20 plates unless otherwise indicated. 8)All plates are 1.5x4 MT20 unless otherwise indicated. 9)Plates checked for a plus or minus 0 degree rotation about its center. 10)Gable studs spaced at 2-0-0 oc. 11)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 12)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 Julius Lee,P.E. 934869 Continued will d on page bbgettw2een the bottom chord and any other members. 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ cuss ype ty y �f 57236R E08 GABLE 1 2 Job Reference o tional aov2asa Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:40 2014 Page 2 1 D:sf8?Y395JXmOwKJyJLvjMGyspll-bhtrpYa3xHchxFL7gPrF?jebiAHLuvREYXLABQzvW8r NOTES 13)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 4401 lb uplift at joint 10 and 1926 lb uplift at joint 16. 14)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 15)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)107 lb down and 121 lb up at 15-10-7,46 lb down and 1 lb up at 16-9-1,120 lb down and 61 lb up at 18-8-12,120 lb down and 61 lb up at 20-8-12,120 lb down and 61 lb up at 22-8-12,120 lb down and 61 lb up at 22-11-4,383 lb down and 447 lb up at 24-11-4,383 lb down and 447 lb up at 26-11-4,and 641 lb down and 844 lb up at 28-10-15,and 210 lb down and 1070 lb up at 29-7-10 on top chord,and 2632 lb down and 2497 lb up at 15-10-5 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(pit) Vert:1-3=-36,3-5=-36,5-6=36,7-9=-36,10-35=-10 Concentrated Loads(lb) Vert:9=-210 38=-97 39=13 40=-110 41=-110 42=221 43=-363 44=363 45=621 46=-2632(B) Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ russ I ype ply 57236R FTG1 I"LATGIRDER 1 2 Job Reference(optional) A0272885 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:40 2014 Page 1 ID:sfB?Y395JXmOwKJyJLvjMGyspil-bhtrpYa3xHchxFL7gPrF?jeeeALNuvPEYXLABQzvW8r 0-0-0 5-0-11 5-0-11 5-0-11 10 1-6 Scale=1:16.7 4x16 3x6 II 4x16 1 2 3 1 T T ST3 ST2 W1 W1 W1 2 W3 W1 ST2 ST3 B1 Li 4' 2x4 11 5 2x4 I I 8x14=4 4 4x12= 6 7x8= 0-0-0 5 0 11 5-0-11 5-011 10-1-6 Plate Offsets(X,Y): [1:0-5-0,0-2-01,[3:0-5-0,0-2-01,[4:0-4-14,0-5-61,[6:0-4-0,0-4-81,[7:0-1-13,0-0-121,[7:0-2-0,0-0-121,[14:0-2-0,0-0-81,[16:0-1-13,0-0-121 LOADING(psf) SPACING 1-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.79 Vert(LL) 0.11 4-5 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.49 Vert(TL) -0.14 4-5 >829 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.91 Horz(TL) -0.00 4 n/a n/a BCDL 10.0 Code FBC2010/rP12007 (Matrix-M) Weight:160 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP M 31 TOP CHORD Structural wood sheathing directly applied or 5-6-9 oc purlins, BOT CHORD 2x6 SP No.2 except end verticals. WEBS 2x8 SP No.2'Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. W2,W3:2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS (lb/size) 6=2832/0-7-4 (min.0-1-11),4=2637/Mechanical Max Uplift6=2296(LC 6),4=2492(LC 6) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-6=2809/2306,1-17=4435/3934,17-18=-4435/3934,2-18=-4435/3934,2-19=4435/3934,19-20=-4435/3934, 20-21=-4435/3934,3-21=-4435/3934,3-4—1909/1908 WEBS 1-5=4255/4796,2-5=-2388/2116,3-5=-4255/4796 NOTES 1)2-ply truss to be connected together with 1 Od(0.131"x3••)nails as follows: Top chords connected as follows:2x8-2 rows staggered at 0-9-0 oc,2x4-1 row at 0-9-0 oc. Bottom chords connected as follows:2x6-2 rows staggered at 0-9-0 oc. Webs connected as follows:2x8-2 rows staggered at 0-9-0 oc,2x4-1 row at 0-9-0 oc. 2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated. 3)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MW FRS(envelope);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 4) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1. 5)Provide adequate drainage to prevent water ponding. 6)All plates are 1.5x4 MT20 unless otherwise indicated. 7)Plates checked for a plus or minus 0 degree rotation about its center. 8)Gable studs spaced at 2-0-0 oc. 9)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 10)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 11)Refer to girder(s)for truss to truss connections. 12)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 2296 lb uplift at joint 6 and 2492 lb uplift at joint 4. 13)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 14)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)687 lb down and 535 lb up at 1-2-0,687 lb down and 530 lb up at 3-2-0,687 lb down and 530 lb up at 3-4-8,687 lb down and 535 lb up at 5-4-8,and 400 lb down and 830 lb up at 7-4-8,and 37 lb up at 9-4-3 on top chord,and 780 lb down and 834 lb up at 5-0-0,and 570 lb down and 481 lb up at 7-0-0,and 570 lb down and 478 lb up at 9-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard Julius Lee,P.E.#34869 Continued on page 2 1109 Coastal Bay Boynton Beach,FL 33435 Job I fuss I mss I ype Y A n 0272885 57236R FTG1 FLATGIRDER 1 2 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:41 2014 Page 2 IDsf8?Y395JXmOwKJyJLvjMGyspl1-3tRD1 uahiakYZPvJD7MUYxBoOZhodMfOnB4BszvW8q LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=36,4-6—10 Concentrated Loads(lb) Vert:5=-780(F)17=-687 18=-1374 19=-687 20=400 21=37 22=-570(F)23=-570(F) Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I toss I ype Qfy I Ply A0272886 57236R HJ5 Roof Special Girder 4 1 o tional Job Reference Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Toe Jan 14 08:12:42 2014 Page 1 IDsf8?Y395JXmOwKJyJLvjMGyspi 1-Y3?bEEbJSusPAZU Wngtj58jzyzORM_1 XOrgHFIzvW8p 0-0-0 3 O 2 3-0-2 2 7 12 5-7-14 1 7-0-2 4.95 12 Scale=1:14.5 4x4 3 T2 2.83 12 NAIL NAIL D 2x4 11 2 NAIL NAIL D Tt W2 W3 OH2 1 W1 I I t _ff LJ B1 111 NAILED 7 6 2x4 NAILED 1.5x4 11 8 2x4 11 5 3x4= 0-0-0 3 0 13 3-0-13 2-7-1 5-7-14 1 7-0-2 Plate Offsets(X,Y): [6:Edge,0-1-81 LOADING(psf) SPACING 2-0-0 CSI DEFL in floc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.80 Vert(LL) -0.03 7-8 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.51 Vert(TL) -0.04 7-8 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.20 Horz(TL) -0.05 4 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:28 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-10-11 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 or bracing, Except: WEBS 2x4 SP No.3'Except* 10-0-0 oc bracing:5-6. W 1:2x8 SP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=46/Mechanical,6=133/Mechanical,8=165/0-4-1 (min.0-1-8) Max Horz8=170(LC 8) Max Uplift4=62(LC 8),6=269(LC 23),8=825(LC 4) Max Grav4=46(LC 1),6=325(LC 32),8=843(LC 39) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-12=-475/377,2-12—421/404,2-13=470/440,3-13=328/340 BOT CHORD 1-8=-369/467,8-14=-369/309,7-14=-369/309,6-7=-332/281 WEBS 2-8=-411/390,3-7—392/325,3-6—444/525 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASIDE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 62 lb uplift at joint 4,269 lb uplift at joint 6 and 825 lb uplift at joint 8. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 9)"NAILED"indicates 3-1 Od(0.148"x3")or 2-12d(0.148"x3.25")toe-nails.For more details refer to MiTeWs ST-TOENAIL Detail. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=72,3-4=-72,5-9=-20 Concentrated Loads(lb) Vert:12=22(F=11,B=11)13=274(F=137,B=137)14=267(F=133,E=133) Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job toss I fuss I ype QtyFly A0272887 57236R HJSA Roof Special Girder 1 1 Job Reference o tionai At ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:42 2014 Page t IDsf8?Y395JXmOwKJyJLvjMGyspll-Y3?bEEbJSusPAZUWngtj58j7Gz5QM1 MXOrgHFIzvWBp 0-0-0 2-9 15 2-9-15 1-4-4 4-2-3 4.95 F12 Scale=1:14A 44= 2.83 F12 2 T2 3x4 II 1 T1 4 W W3 p 1 2 W1 I I B7 5 3x6= 6 4 3x4= 4-2-30 0 2.9-15 2 9 15 1-4-4 4-1-3 Plate Offsets(X,Y): [5:Edge,0-1-81,(6:0-2-4,0-1-81 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.14 Vert(LL) -0.01 5-6 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.19 Vert(TL) -0.03 5-6 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.05 Horz(TL) -0.00 5 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:22 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 7-0-2 oc puffins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3`Except' BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. W 1:2x8 SP No.2 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=46/Mechanical,5=133/Mechanical,6=249/0-4-1 (min.0-1-8) Max Horz 6=103(LC 8) Max Uplift3=-62(LC 8),5=115(LC 8),6=241(LC 4) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a five load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 62 lb uplift at joint 3,115 lb uplift at joint 5 and 241 lb uplift at joint 6. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 9)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)29 lb down and 59 lb up at 1-5-0,and 29 lb down and 59 lb up at 1-4-15 on top chord,and 14 lb down and 14 lb up at 1-5-0,and 14 lb down and 14 lb up at 1-4-15 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-2=-72,2-3=-72,4-6=-20 Concentrated Loads(lb) Vert:1=-58(F=29,B=29)6=-17(F=-8,B=8) Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I russ 1 ype Qry y 57236R HJ6 Roof Special Girder 1 1 Job Reference(optional) A0272888 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:43 2014 Page 1 I D:sf8?Y395JXmOwKJyJLvjMGyspl l-OGZzSacxDC_Goj3iLYPydMG9NNKy5OrgEVZgolzvWBo 0-0-0 3-0-2 5-7-14 8-11-5 9-1-5 3.0-2 2-7-12 3.3-7 Q 2 p Scale=1:18.9 4.95 12 2x4 II 5 4 NAILE NAILE 4x4 T2 2.83 12 3 NAIL NAIL D 2x4 11 2 W4 N IL IL D T1 1 W1 W2 B1 111 Q o NAILED 8 NAILED 7 3x6= Q o NAILED 1.5x4 11 NAILED 3x8_ 9 6 2x4 I I 0-0-0 3-3-4 3.3.4 2-411 5 7-14 3-3-7 a-1125-9-1-5 Plate Offsets(X Y): f7:013-4 0-1-81 4 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.76 Vert(LL) 0.12 7-8 >548 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.69 Vert(TL) -0.12 7-8 >528 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.42 Horz(TL) -0.01 7 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight:45 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP M 30'Except' TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. T2:2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: BOT CHORD 2x4 SP M 30 10-0-0 oc bracing:6-7. WEBS 2x8 SP No.2*Except* MiTek recommends that Stabilizers and required cross W2,W3:2x4 SP No.3 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 9=974/0-11-5 (min.0-2-1),7=-199/Mechanical Max Horz 9=249(LC 34) Max Uplift9=-1595(LC 4),7—504(LC 17) Max Grav9=1740(LC 43),7=305(LC 30) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-13=989/977,2-13=1047/1150,2-14—1027/1096,3-14=885/996 BOT CHORD 1-9=-1034/1026,9-16=1034/810,8-16=-1034/810,8-17=-981/770,7-17=981/770 WEBS 2-9—864/748,3-8=-565/416,3-7=867/1104 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 1595 lb uplift at joint 9 and 504 lb uplift at joint 7. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 9)"NAILED"indicates 3-1 Od(0.148"xY)or 2-12d(0.148"x3.25")toe-nails.For more details refer to MiTek's ST-TOENAIL Detail. 10)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)316 lb down and 236 lb up at 1-2-0,and 316 lb down and 236 lb up at 1-2-0 on top chord. The design/selection of such connection device(s)is the responsibility of others. 11)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-3=72,3-5=-72,6-10=20 Concentrated Loads(lb) Vert:13=582(F=-291,B=-291)14=274(F=137,B=137)15=64(F=32,B=32)16=267(F=133,B=133)17=40(F=20,B=20) Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ russ I ype Qty y A0272889 57236R HJ7 Jack-Open Girder 3 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:44 2014 Pa gge 1 ID:sf8?Y395JXmOwKJyJLvjMGyspl l-US7Lfvda_V66QteuvFwBAZpHMndnqungT9JNKBzvWBn 0-0-0 3-0-2 5-7-14 9-10-1 3-0-2 2-7-12 4-2-3 Scale=120.2 4.95 12 NAILE NAILE T2 4x4 2.83 F12 NAI 3 o a NAIL D C? 19 2x4 11 0 a fo NAIL 2 N IL D T1 1 W W2 3 P 1t �F1 B1 LJ d o• NAILED 7 NAILED 6 3x4= B B NAILED 1.5x4 11 NAILED 8 3x4=5 2x4 11 0-0-0 3-3-4 3-g4 2-4-11 `5-7,14 42 3 9-10-1 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.93 Vert(LL) 0.15 6-7 >521 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.84 Vert(TL) 0.15 6-7 >504 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.25 Horz(TL) -0.09 4 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:41 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-4-15 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 5-7-10 oc bracing. WEBS 2x4 SP No.3'Except* MiTek recommends that Stabilizers and required cross Wi:2x8 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=126/Mechanical,8=410/0-11-5 (min.0-1-8),6=-103/Mechanical Max Horz 8=278(LC 34) Max Uplift4=-208(LC 8),8_1188(LC 4),6=236(LC 17) Max Grav4=136(LC 23),8=1233(LC 39),6=220(LC 30) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-12=812/659,2-12=-759/699,2-13=-802/715,3-13=-660/615 BOT CHORD 1-15=-641/788,8-15=-641/788,8-16=-641/549,7-16=641/549,7-17=-609/524,6-17=-609/524 WEBS 3-7=-336/264,2-8=559/531,3-6=-562/653 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60 3)This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Refer to girder(s)for truss to truss connections. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 208 lb uplift at joint 4,1188 lb uplift at joint 8 and 236 lb uplift at joint 6. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. 10)"NAILED"indicates 3-10d(0.148"x3")or 2-12d(0.148"x3.25")toe-nails.For more details refer to MiTews ST-TOENAIL Detail. 11)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)105 lb down and 78 lb up at 1-2-0,and 105 lb down and 78 lb up at 1-2-0 on bottom chord. The design/selection of such connection device(s)is the responsibility of others. 12)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 Uniform Loads(plf) Vert:1-372,3-4—72,5-9=20 Concentrated Loads(lb) Vert:12=22(F=11,B=11)13=274(F=137,B=137)14=64(F=32,B=32)15=-200(F—100,B=-100)16=267(F=133,B=133) 17=40(F=20,B=20) Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 O russ SS ype y 57236R J5 JacR1k-Open 10 1 Job Reference(optional) A0272690 At ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MITek Industries,Inc.Tue Jan 14 08:12A5 2014 Page 1 1 Dsf8?Y395JXmOwKJyJLvjMGyspl1-yeh ktFe CIpEz10D5SyRQinLYyBO UZNLzip2xsdzv W8m 0-0-0 4 0-0 4-" 1-0-0 5.0 0 7.00 F12 Scale=1:14.2 4x4 3 T2 4.00 F12 1.5x4 II 2 N N T1 0 N W2 1 W1 B1 6 2x4= �. Q 1.5x4 11 7 1.5x4 II 0-0-0 2-4-0 2-4-0 1-8-0 4-" 1" 5-0-0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl, Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.56 Vert(LL) -0.03 6-7 >904 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.62 Vert(TL) -0.03 6-7 >978 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.10 Horz(TL) 0.10 4 n/a n/a BCDL 10.0 Code FBC201 OTrP12007 (Matrix-M) Weight:19 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x6 SP No.2*Except* MiTek recommends that Stabilizers and required cross W2:2x4 SP No.3 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=34/Mechanical,5=-10/Mechanical,7=431/0-3-2 (min.0-1-8) Max Horz 7=171(LC 12) Max Uplift4=-52(LC 12),5=-41(LC 12),7=-492(LC 8) Max Grav4=48(LC 21),5=89(LC 10),7=431(LC 1) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=336/164 BOTCHORD 1-7=-169/345 WEBS 2-7=-337/800 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 52 lb uplift at joint 4,41 lb uplift at joint 5 and 492 lb uplift at joint 7. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E.#34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ russ I ype ty y 57236R J5B Jack-Open 4 1 Job Reference(optional) A0272891 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:46 2014 Page 1 I D:sf8?Y395JXmOwKJyJLvj MGyspl l-OrE64beq W 7MgfAo HOgyf F_unNaR71 ri7wToUO3zv W81 0-0-0 2-0-0 2-0-03-0-0 p 1-0-0 7.00 F12 Scale=1:14.3 4.00 12 4x4 2 T2 2x4 II 1 T1 T N N O N W2 W1 Ll 1311 5 1.5x4 II 6 3x4 11 G40 2-0-0 2-0-0 1 0 0 340 Plate Offsets(X,Y): f2:0-2-0,0-2-41 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.26 Vert(LL) 0.02 5-6 >999 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.27 Vert(TL) 0.02 5-6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.03 Horz(TL) -0.03 3 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:13 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x6 SP No.2'Except' BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. W2:2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 3=76/Mechanical,4=49/Mechanical,6=125/0-3-2 (min.0-1-8) Max Horz 6=103(LC 12) Max Uplift3=109(LC 12),4=45(LC 12),6=-58(LC 8) Max Grav3=77(LC 21),4=49(LC 1),6=125(LC 1) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=O.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 109 lb uplift at joint 3,45 lb uplift at joint 4 and 58 lb uplift at joint 6. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job cuss I russ I ype ty y o tional Job Reference A0272692 57236R J6 Roof Special 1 1 At ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Pdnt:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 0&12:46 2014 Page 1 IDsf8?Y395JXmOwKJyJLvjMGyspl t-OrE64begW7MgfAoHOgyfF_ulXaOblot7wToUO3zvW81 0-0.0 40 0 4-0-0 6-" 6-6-6 Scale=1:19.5 1 7.00 12 .5x4 II 5 4 T2 4x4 4.00 F12 3 1.5x4 II W3 2 T1 1 W1 W2 0148 B1 6 7 2x4_ U 1.5x4 I I 9 6 1.5x4 II 1.5x4 II 2-0-0 4-6-6 0-" 2-4-0 2-4-0 1-6-0 4-0-0 2-6-6 6-6-6 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.44 Vert(LL) -0.08 7-8 >574 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.50 Vert(TL) -0.09 7-8 >537 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.21 Horz(TL) -0.00 7 n/a n/a BCDL 10.0 Code FBC2010[TPI2007 (Matrix-M) Weight:28 lb FT=0 LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 SP No.2 except end verticals. WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 7=1 31/Mechanical,9=459/0-8-0 (min.0-1-8) Max Horz9=254(LC 12) Max Uplift7=-208(LC 12),9=-465(LC 8) Max Grav7=232(LC 21),9=459(LC 1) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=465/268,4-7=250/248 BOT CHORD 1-9=-278/474 WEBS 3-8=273/189,2-9=274/708 NOTES 1)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MW FRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 2)Plates checked for a plus or minus 0 degree rotation about its center. 3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5)Refer to girder(s)for truss to truss connections. 6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 208 lb uplift at joint 7 and 465 lb uplift at joint 9. 7)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 Job I russ I russ I ype ly A0272893 57236R J7 Jack-Open 187 1 Job Reference(optional) Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MiTek Industries,Inc.Tue Jan 14 08:12:47 2014 Pa gge 1 ID:sf8?Y395JXmOwKJyJLvjMGyspll-ul oUHxfSHOUhHKNTaNTuoCRxUyT1 G6G97X2xWz 118k 0-0-0 40 0 4-0-0 3 0 0 7-0.0 Scale=1:20A 7.00 F,2 T2 44 4.00 12 3 Ncl n 1.5x4 II c8 2 T1 1 W1 W2 B1 6 2x4= 6 7 1.5x4 II 1.5x4 II z-o-0 5-0-00 0 2-4-0 2 4 0 1-8-0 3-0-0 LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.37 Vert(LL) -0.15 5-6 >377 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.71 Vert(TL) -0.17 5-6 >318 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.08 Horz(TL) 0.10 4 n/a n/a BCDL 10.0 Code FBC2010(rP12007 (Mat(x-M) Weight:26 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x6 SP No.2*Except* MiTek recommends that Stabilizers and required cross W2:2x4 SP No.3 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=106/Mechanical,5=52/Mechanical,7=48110-8-0 (min.0-1-8) Max Horz7=278(LC 12) Max Uplift4—165(LC 12),5=62(LC 12),7=-449(LC 8) Max Grav4=152(LC 21),5=119(LC 10),7=481(LC 1) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-2=502/300,2-3=286/269 SOT CHORD 1-7=312/511 WEBS 2-7=-250/663,3-6—346/236 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;VuIt=180mph(3-second gust)Vasd=139mph;TCDL=S.Opsf;BCDL=S.Opsf;h=45ft;Cat.II;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces& MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)Plates checked for a plus or minus 0 degree rotation about its center. 4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6)Refer to girder(s)for truss to truss connections. 7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 165 lb uplift at joint 4,62 lb uplift at joint 5 and 449 lb uplift at joint 7. 8)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435 f Job cuss I russ I ype Uty y Job Reference(optional) A0272894 57236R �J71? Jack-Open 7 1 Al ROOF TRUSSES,FORT PIERCE,FL 34946,Ryan Spencer Run:7.500 s Nov 26 2013 Print:7.500 s Nov 26 2013 MTek Industries,Inc.Tue Jan 14 08:12:48 2014 Page 1 ID:sf8?Y395JXmOwKJyJLvjMGyspll-MDMsVHg42kcYuUyg85_7KPz3eOOmmjCQOnHbTyzvW8j 0-0-0 40 0 4-0-0 3-0-0 7-0-0 Scale=120.4 7.00 12 T2 4x4 4.00 12 3 r; N 1-5x4 II N " 2 w Tt 0,1,8 1 W1 W2 3 —I Ll 131 LJ d 6 7 6 2x4= ° 8 1.5x4 II 5 1.5x4 II 3x4= 2-0-0 5-0 0 2-4-0 2�0 i 8-0 4°° 3-0-0 ° LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.53 Vert(LL) 0.09 6-7 >593 360 MT20 244/190 TCDL 16.0 Lumber Increase 1.25 BC 0.71 Vert(TL) 0.08 6-7 >664 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(TL) 0.06 4 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:30 lb FT=0% LUMBER BRACING TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3'Except' MiTek recommends that Stabilizers and required cross W1:2x6 SP No.2 bracing be installed during truss erection,in accordance with Stabilizer Installation guide. REACTIONS (lb/size) 4=106/Mechanical,8=480/0-8-0 (min.0-1-8),6=54/Mechanical Max Horz8=278(LC 12) Max Uplift4—165(LC 12),8=-593(LC 8),6=-179(LC 9) Max Grav4=152(LC 21),8=480(LC 1),6=82(LC 3) FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. BOT CHORD 1-8=116/259 WEBS 2-8=-341/743,3-6_197/257 NOTES 1)Unbalanced roof live loads have been considered for this design. 2)Wind:ASCE 7-10;Vult=180mph(3-second gust)Vasd=139mph;TCDL=5.Opsf;BCDL=5.Opsf;h=45ft;Cat.11;Exp D;Encl., GCpi=0.18;MWFRS(envelope)and C-C Exterior(2)zone;cantilever left and right exposed;porch left exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60 3)This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 4)Plates checked for a plus or minus 0 degree rotation about its center. 5)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7)Refer to girder(s)for truss to truss connections. 8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 165 lb uplift at joint 4,593 lb uplift at joint 8 and 179 lb uplift at joint 6. 9)"Semi-rigid pitchbreaks with fixed heels"Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee,P.E. #34869 1109 Coastal Bay Boynton Beach,FL 33435