Loading...
HomeMy WebLinkAboutBuilding Plans HVAC1 I 2 I 3 I--- 1 U I 1 1 N 9 L K J 117 IVAA"' k0_1111111111111110-W-1 F E I C G-1 1/4 of= 1 0 _091 A-1 1/4 01=1 ' — 0" 1 I I I 1 1 I I 1 1 I 1 1 I I I 1 1 I 2 SECOND LEVEL FIRST LEVEL 3 0 5 C 7 Vj'oT I 10 12 1 13 14 15 16 ELECTfRICAL LEGEND 0 Zn V� NN ELECTRIC METER a.f5M ^N ~ m� �M Gd ELECTRIC PANEL0. W v Q a N fY A/C DISCONNECT r5V ^^ 0 • 0m vm lu ® 240 VOLT RECEPTACLE a. 0= zW g 10 z DUPLEX OUTLET ol 0 ? b Nm a..� DUPLEX OUTLET - HALF SWITCHED U R W-P- 191C WEATHER PROOF DUPLEX OUTLET GF.C.I. Q TELEPHONE JACK U] TELEVISION JACK A IVI O CENTRAL VAC. HOSE OUTLET -64 WALL SWITCH -6� 3-WAY WALL SWITCH 47 ' 4-WAY WALL SWITCH a o -64P DIMMER WALL SWITCH a ;L Q PUSH BUTTON SWITCH o a WALL OR CLG. MOUNTED FIXTURE N mtn U) L J. BOX 1 w n .N�, JUNCTION BOX a m Y; PULL CORD FIXTURE ® RECESSED LIGHT FIXTURE V.P. ❑ VAPOR PROOF RECESSED FIXTURE Nco o P � _ 0' M F---I FLOURESCENT LIGHT FIXTURE W tI a v FLOOD LIGHTS O EXHAUST FAN 0 1LO ® SMOKE DETECTOR OT THERMOSTAT W 8T SPRINKLER TIMER WZ INTERCOM ; 0 Kf7f SECURITY SYSTEM KEYPAD W N M MOTION DETECTOR /� V D MO J Z Uu oa CHIME THESE PLANS AND ALL PROPOSED WORD Z v0 Q cABON MONOXIDE DETECTOR ARE SUBJECT TO ANY CORRECTIONS 10 INSPECTORS DOOR ALARM SOUND WHEN OFNED REQUIRED BY FIELD ECTORS THAT z ° Y BE NECESSARY IN ORDER TO 0 0 COMPLY WITH ALL APP Ll�:ASLE U � m CODES, H AFF -ELECTRICAL CONTR,4CT0 SHALL VERIFY WITH FPkL THE LOCATION SERVIC AND SHALL LOCATE THE M ER 4 PANEL AS REQUIRED. -ALL ELECTRICAL WORK TO C FORM TO THE 2002 NATIONAL ELECTRIC CODE -ALL OUTLET BOXES FOR RECE ACLES, TV ANTENNAS, OR TELEPHONE JACKS IN RATED WALLS MUST BE METAL OR U.L. RATED F USE IN ONE HOUR CONSTRUCTIO (PROVIDE OPTIONAL CAT-5 HIGH EED DATA OUTLETS- ONLY PE OWNER REQUEST) -ALL BATHROOM AND GARAGE OUTLE TO BE CzF.C.I. TYPE. - 2m AMP. CIRCUIT -ALL OPENINGS REQUIRED BY ELECTRIC CONTRACTOR TO E CLOSED TO MATCH FINISH AND FIRE RATED BY ELECTRICAL CONT TOR -INSTALLATION HEIGHTS ABOVE FINISH FLUOR LESS OT RW15E NOTED: WALL HUNG TELEPHONE 5(o" AFF TELEPHONE JACKS 12" AFF LIGHT SWITCHES 40" AFF RECEPTACLES 12" AFF TELEVISION JACKS 12" AFF - ALL BEDROOM CIRCUITS SHALL BE ARC -FA T PROTECT (NEC 210-12(5) -ELECTRICAL CONTRACTOR TO CONFORM ITH TELEPHONE C REQUIREMENTS FOR TELEPHONE EQUIPMENT INSTALLATION. -CO-ORDINATE ALL CONDUIT RUNS A EQUIPMENT INSTALLATION ITH OTHER TRADES TO AVOID CONFLICTS PRIOR TO FAB ATION, INSTALLATION AND ERE TION. -ELECTRICAL CONTRACTOR TO V RIFY ALL HVAC UNIT CONNECTIONS TH HVAC UNIT CONNECTIONS WITH HVAC ONTRACTOR PRIOR TO INSTALLATION. -ALL METERS, METER CENT S AND DISCONNECTS TO BE APPROVED BY FL RIDA POWER AND LIGHT. -ALL SMOKE DETECTOR SHALL BE 110 VOLT, HARDWIRED TO DEDICATED CIR T BATTERY BACK-UP, i TER -CONNECTED, AND INTEGRAL WITH ALARM SYSTEM. -ELECTRICAL CONT CTOR SHALL NOT INSTALL OUTLET BOXES BACK TO BACK : IS IS IN ORDER TO PREVENT SOUND NSMISSION BETWEEN ROOMS -ALL RECEPTA LES AND SWITCHES TO BE DECORA TYPE. (U.N.O.) G14 GENERAL NOTES 12 13 14 15 16 Ec c � 1U¢ 0 Z o � w r z 04 W n r r F+1 W t�l1 1 � z 0 A3 W M LO v� Drawn by: MOH HVN Project No. Cadd File NO.: Sheet No: Kcs D011 of --sheets 1 2 3 4 5 6 7 8 SYMBOL MANUFACTURE MODEL WATTAGE TOTAL TYPE OF MOUNTING 8c LAMP M()UNT HEIGHT N Q BEAGHSIDE L-014 3 WATT WITH 4 WALL MTD (4) 6'-8" AFF. Q FIRST LEVEL LIGHTING I LED AMBER 0 I B LIGHTING E I�,, E12 I LED AMBWITH ER 19 M © I B IGHTING E I L-016F I 3 WATT WITH I LED AMBER I L UJALL MTD (2) 2'-0" AFF. e FIRST LEVEL f'.ECESSED (4) 1'-0" AFF. 6 SECOND LEVEL (3) P-0" AFF. 6 THIRD LEVEL RECESSED (I)- W-0" AFF. -S FIRST LEVEL CEILING MTD I� K-13 EXTERIOR LIGHT'G SGHED. NOTE: ALL WINDOWS AND DOORS TO HAVE TURTLE TINTED GLASS NTS (4E)% MAXIMUM LIGHT TRANSMITTANCE) J IN 011111 C I n / A-1 1/4 $$=if_Of$ 1 THIRD LEVEL T HVAC 9 Second Floor Third Floor Manuf: Trane Trane C[U Model#: 4TTB4060E 4TTG4048E A/H Model#: GAT2AOC60S51 GAT2AOC48 KW# 10 10 SEER 14 14 CFMs 1500 14'"75 Total BTUs 55500 45000 ARI 4941126 4941123 EFl 50 CFMs Notes: 1. Duct location may change due to construction issues. 2. Flexible R-6 duct may be substituted for ductboard. 3. Return duct may be direct or indirect. 4. Balancing dampers on accessible duct only. 5. Exhaust fans provided by electrician, selected by homeowner. 6. Exhaust vents may be in roof, wall or soffit. 7. Options: Zone Damper System, Filter ]tacks and UV Lights. 8. Equipmont Options: Increase to 16 SEER 4TTB40,19E & TAM7AOC48 and 4TTB4061E & TAM7AOC43 7862 SW Ellipse Way Stoar4 FL 34997 Phone:771220.2487 N072.220.3787 WWW.Sharkeor.com lic.# CAC049289 Uc.# CAC 1816853 ELEC-17RICAL LEGEND g EI,.ECTRIC METER 0 EL.ECTRIC PANEL QJ A/C DISCONNECT ® 24-0 VOLT RECEPTACLE DUPLEX OUTLET DUPLEX OUTLET - HALF SWITCHED W.P. GF.C.I. WEATHER PROOF DUPLEX OUTLET Q TELEPHONE JACK E TELEVISION JACK OV CENTRAL VAC. NOSE OUTLET 44 WALL SWITCH 4,)°' 3. WAY WALL SWITCH 44a 4-•WAY WALL SWITCH -(,4R DIMMER WALL SWITCH 0 PUSH BUTTON SWITCH WALL OR CLG. MOUNTED FIXTURE -�- EXTERIOR WALL MOUNTED FIXTURE J. BOX 1 —(Y}— JUNCTION BOX L PULL CORD FIXTURE ® 1;ZFCESSED LIGHT FIXTURE V.P. ® VAPOR PROOF RECESSED FIXTURE FLOURESCENT LIGHT FIXTURE FLOOD LIGHTS O EXHAUST FAN O SMOKE DETECTOR O TwERMOSTAT BT spRINKLER TIMER INTERCOM ® SECURITY SYSTEM KEYPAD �y I MLOTION DETECTOR CHIME 12 13 14 TYPE SQ D, LOAD CENTER SERVICE 120 / 240 10 3W MOUNTING FLUSH POLES: 40 15 16 MAIN BUS 200 AMPS NEUTRAL FULL MAINS M.L.O. A.I.G. 10,000 ELECTRICAL PANEL 1,4' BRKR WIRE LOAD (W.) DESCRIPTION CKT! CKT.• DESCRIPTION LOAD (W.) WIRE SRKR. 40/2 11500 A.H.0 01 W/ HEATSTRIP I 2 A.C. COMPRESSOR 01 5000 N/C 08 30/2 3 4 20/2 010 1200 INLINE WATER HEATER (GAS) 5 6 OVEN 5000 OF 40/2 1 8 20/2 010 120 COOKTOP (GAS) S 10 WATER HEATER 4 0 olo 25/2 Il 12 20/2 010 2500 RYER 13 14 SUB-FNL B IRRIGATION PUMP OF 12,225 3500 % 012 60/2 25/2 15 16 20/1 #12 1200 WAXER 11 18 20/I 012 1200 JACC I PUMP I9 �0 20/1 012 O LAUNDR IGHTS 21 22 GF.I. RECEPT. O -14 20/1 20/1 012 0 GF.C.I. REC NT. BATHROOMS 23 24 EXTERIOR LIGH 1 20/1 012 G.F.I. RECEPT- UTSIDE 25 26 DRYER 2500 010 20/2 20/1 012 GF.I. RECEPT. OXSIDE 2'1 28 20/1 012 1200 WASHER 29 30 SPARE 20/1 012 SPARE 31 32 SPA SPACE 31 38 9 NOTES: N/C = NON CONCURENT A/C LC TYPE SQ D, LOAD CENTER SERVICE 120 / 240 10 3W MOUNTING FLUSH POLES: 40 MAIN BUS 60 AMPS NEUTRAL FULL MAINS M.L.O. A.I.G. 10000 SUS f=ANEL S (GENERATOR OPTIONAL) BRKR WIRE LOAD (W.) DESCRIPTION CKT9 CKT.M DE-AtIPTION LOAD (W.) WIRE BRKR. 20/1 012 0 G.F.I. RECEPT. GA E 1 2 GF.C.I. CEPT. BATHROOMS 012 20/1 15/1 014 M. BEDROOM 3 4 DEN / GU T DEN/ GUEST 014 15/1 M. BEDROO 5 6 a M. BATH GHTS 1 BEDROOM 02 M. BA LIGHTS 9 10 12 14 16 18 20 $2A.C. BEDROOM 03 KIT EN LIGHTS 11 LIVING ROOM 20/1 012 1200 FRIGERATOR 13 LIVING ROOM 20/1 012 1200 DISHWASHER 15 DISPOSAL 1200 012 20/1 20/1 012 1200 GARAGE DOOR OFENER 11 MICROWAVE 1200 012 -2oll 20/1 012 SPARE 19 SPARE 40/2 06 1500 A.H.0 02 W/ HEATSTRIP 21 COMPRESSOR 02 00 08 30/2 23 24 26 28 30 SPACE 25 j SPACE _ 21 2S 0 ALL BEDROOM CIRCUITS SHALL 5E ARC -FAULT PROTECTED (NEC 210-12(5) GEN LIGHTING ( 368(o SF 'a 3W/8F) = 11050 W. (GEN LIGHTING INCLUDING GARAGE, PATIO AND BALCONY) LOAD CAL LATIONS / REl" IAINING KUJ, 4!a% 15.5 A/C HEAT STRIP .0 5io 12.15 3�jo50 KW. 3-02/0 PPER IN 2" PV MAIN BKR DK200 COMBO 200 NEUTRAL 3FEJ] AC. -1 AHU. h 04 AMP 5r�'���IRRG =CQUIP. b DRYERD 8 METER MAIN FEED BLANK BLANK 10 THROUGH LUGS FILTER UNDERGROUND TO FP4L TIE-IN LOCATION / 3-165o 240 V. 156.9amp 1*'4 COPPER GROUND TO 5/5x8' GROUND ROD 4 COLD WATER PIPE 4 FOUND. STEEL NOTE: ,ALL FIXTURES IN CLOSETS TO COMPL"r W1 NEC 410-8 ELECT F-,,,f SAL fR15EIR G 14 GENERAL NOTES 13 14 2% W/ 108 NEUTRAL IN 3/4" P.V.G. 100 ,4I IF SUS PNL S Z •0 ZZ p m W !7 IL M Q LU N 0 Q it a 06 co . • —m �m a' 0 z 11 lily O (3/lp V)0 �°I NM aW III© a o l.i � W 0 0 a. = j W L M rn w ■t� m M 0. IS 0 ��L co M m la 10 LO W LU _Z 0 (14 J W 0 �J M D M 0 Z u U. sZ 4. v0 D 1 ~ 3� N Z .o u 0 �0 co U Fs 0 IL C4 0 0 o f 6 LL_ a oQ so� I-- E c o £-oil£ �5 ■0 W4 0 U� o W� W C-) E w V) a CDCD N Mi O 3 w MLO _ Drawn by: MOH HVN Project No. Cadd File NO.: DATE DESIGN PROGRESS O4-30-12 BIDDING SET #1 06-29-12 FINAL BID SET 04-30-13 PERMIT SET 06-30-13 C Sheet No: A of --sheets 4 I 5 I 6 I 7 I 8 I 9 I 10 I 11 I 12 15 I 16