HomeMy WebLinkAboutEnergy CalculationFORM 1100A-08
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs'Residential Performance Method A
Project Name: Masterpiece -Doyle
Builder Name: Sharkey Air LLC
Street: 53 Watersong Street
Permit Office:
City, State, Zip: St. Lucie County, FI ,
Permit Number:
Owner: Doyle Residence
Jurisdiction:
Design Location: FL, ST LUCIE_CO_INTL
1. New construction or existing New (From Plans)
9. Wall Types (5120.2 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=19.0 4990.20 ft2
b. Concrete Block - Int Insul, Exterior
R=19.0 130.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2247.0 sqft.)
Insulation Area
6. Conditioned floor area (ft2) 3643.8333333333
a. Under Attic (Unvented)
R=30.0 2247.00 ft2
b. N/A
R= ft2
7. Windows(751.0 sqft.) Description Area
c. N/A
R= ft2
a. U-Factor: Dbl, U=0.47 617.00 ft2
SHGC: SHGC=0.52
11. Ducts (combined)
b. U-Factor: Dbl, U=0.49 110.00 ft2
a. Sup: Attic Ret: Attic AH: Interior Sup.
R= 6, 753 ft2
SHGC: SHGC=0.32
12. Cooling systems (combined)
c. U-Factor: Dbl, U=0.45 24.00 ft2
a. Central Unit
Cap: 110.0 kBtu/hr
SHGC: SHGC=0.61
SEER:14
d. U-Factor: N/A ft2
13. Heating systems (combined)
SHGC:
a. Electric Strip Heat
Cap: 53.0 kBtu/hr
e. U-Factor: N/A ft2
COP: 1
SHGC:
8. Floor Types (3605.0 sqft.) Insulation Area ,�
water systems
Y' 1 ctric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3605.0
EF: 0.9
b. N/A R=
Conservation features
c. N/A R= ft `.'
None
15. Credits
Pstat
Total As -Built Modified Loads: 55.18
Glass/Floor Area: 0.206
PASS
Total Baseline Loads: 69.85
I hereby certify that the plans and c er y
Review of the plans and
1E ST,
y
Code.
this calcu;Z70
specifications covered by this
c Iculation indicates compliance
PREPA
with the Florida Energy Code.'
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
i
* ,,
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy CV49dk
OWNER/AGENT: e
BUILDING OFFICIAL:
DATE: - 3 0 - 13
DATE:
9/20/2013 2:27 PM EnergyGauge® USA - FlaRes2008 Page 1 of 6
T
PROJECT
Title:
Masterpiece -Doyle
Bedrooms: 4
Adress Type:
Street Address
Building Type:
FLAsBuilt
Conditioned Area: 3643.83333333333
Lot #
Owner:
Doyle Residence
Total Stories: 3
Block/SubDivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Sharkey Air LLC
Rotate Angle: 0
Street:
53 Watersong Street
Permit Office:
Cross Ventilation: No
County:
St. Lucie County
Jurisdiction:
Whole House Fan: No
City, State, Zip:
St. Lucie County,
Family Type:
Single-family
FI ,
New/Existing:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design
Location TMY Site
Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90
75
70 722
58
Medium
FLOORS
#
Floor Type
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1
Slab -On -Grade Edge Insulatio
35 ft 0
360 ft2
1 0
0
2
Slab -On -Grade Edge Insulatio
1 ft 0
60 ft2
1 0
0
3
Slab -On -Grade Edge Insulatio
1 ft 0
1188 ft2
1 0
0
4
Slab -On -Grade Edge Insulatio
1 ft 0
56 ft2
1 0
0
5
Slab -On -Grade Edge Insulatio
1 ft 0
54 ft2
1 0
0
6
Slab -On -Grade Edge Insulatio
36 ft 0
243 ft2
1 0
0
7
Slab -On -Grade Edge Insulatio
34 ft 0
289 ft2
1 0
0
8
Slab -On -Grade Edge Insulatio
1 ft 0
289 ft2
1 0
0
9
Slab -On -Grade Edge Insulatio
24 ft 0
286 ft2
1 0
0
10
Slab -On -Grade Edge Insulatio
12 ft 0
72 ft2
1 0
0
11
Slab -On -Grade Edge Insulatio
18 ft 0
180 ft2
1 0
0
12
Slab -On -Grade Edge Insulatio
31 ft 0
196 ft2
1 0
0
13
Slab -On -Grade Edge Insulatio
27 ft 0
196 ft2
1 0
0
14
Slab -On -Grade Edge Insulatio
7 ft 0
136 ft2
1 0
0
ROOF
Roof Gable Roof
Solar
Deck
V #
Type Materials
Area Area Color
Absor.
Tested Insul.
Pitch
1
Gable or Shed Metal
2368 ft2 374 ft2 Medium
0.96
No 0
18.4 deg
ATTIC
V #
Type Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Unvented 0 2247 ft2
N N
8/13/2013 11:52 AM EnergyGauge® USA - FlaRes2008 Page 2 of 6
CEILING
#
Ceiling Type
R-Value
Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
39
360 ft2
0.1
Wood
2
Under Attic (Unvented)
39
243 ftZ
0.1
Wood
3
Under Attic (Unvented)
39
289 ftZ
0.1
Wood
4
Under Attic (Unvented)
39
289 ft2
0.1
Wood
5
Under Attic (Unvented)
39
286 ftz
0.1
Wood
6
Under Attic (Unvented)
39
72 ft2
0.1
Wood
7
Under Attic (Unvented)
39
180 ft2
0.1
Wood
8
Under Attic (Unvented)
39
196 ft2
0.1
Wood
9
Under Attic (Unvented)
39
196 ft2
0.1
Wood
10
Under Attic (Unvented)
39
136 ft2
0.1
Wood
WALLS
Cavity
Sheathing
Framing
Solar
#
Ornt Adjacent To
Wall Type
R-Value
Area
R-Value
Fraction
Absor.
1
SE Exterior
Concrete Block - Ext Insul
19
150 ft2
0
0
0.8
2
SW Exterior
Concrete Block - Ext Insul
19
70 ft2
0
0
0.8
3
NW . Exterior
Concrete Block - Ext Insul
19
216 ft2
0
0
0.8
4
NE Exterior
Concrete Block - Ext Insul
19
40 ft2
0
0
0.8
5
SE Exterior
Concrete Block - Ext Insul
19
90 ft2
0
0
0.8
6
SE Exterior
Concrete Block - Ext Insul
19
75 ft2
0
0
0.8
7
SE Exterior
Concrete Block - Ext Insul
19
125 ft2
0
0
0.8
8
NE Exterior
Concrete Block - Ext Insul
19
311.6666
0
0
0.8
9
SE Exterior
Concrete Block - Ext Insul
19
420 ft2
0
0
0.8
10
NW Exterior
Concrete Block - Ext Insul
19
750 ft2
0
0
0.8
11
SW Exterior
Concrete Block - Ext Insul
19
84.16666
0
0
0.8
12
NW Exterior
Concrete Block - Ext Insul
19
135 ft2
0
0
0.8
13
SE Exterior
Concrete Block - Ext Insul
19
180 ft2
0
0
0.8
14
SW Exterior
Concrete Block - Ext Insul
19
168.3333
0
0
0.8
15
NE Exterior
Concrete Block - Ext Insul
19
90 ft2
0
0
0.8
16
SE Exterior
Concrete Block - Ext Insul
19
337.5 ft2
0
0
0.8
17
NW Exterior
Concrete Block - Ext Insul
19
150 ft2
0
0
0.8
18
NE Exterior
Concrete Block - Ext Insul
19
170 ft2
0
0
0.8
19
NW Exterior
Concrete Block - Ext Insul
19
212.5 ft2
0
0
0.8
20
SE Exterior
Concrete Block - Ext Insul
19
150 ft2
0
0
0.8
21
NW Exterior
Concrete Block - Ext Insul
19
150 ft2
0
0
0.8
22
SE Exterior
Concrete Block - Ext Insul
19
150 ft2
0
0
0.8
23
SE Exterior
Concrete Block - Ext Insul
19
225 ft2
0
0
0.8
24
SE Exterior
Concrete Block - Ext Insul
19
50 ft2
0
0
0.8
25
SW Exterior
Concrete Block - Ext Insul
19
140 ft2
0
0
0.8
26
NW Exterior
Concrete Block - Ext Insul
19
150 ft2
0
0
0.8
27
SE Exterior
Concrete Block - Ext Insul
19
200 ft2
0
0
0.8
28
SW Exterior
Concrete Block - Int Insul
19
130 ft2
0
0
0.8
8/13/2013 11:52 AM EnergyGaugeO USA - FlaRes2008 Page 3 of 6
DOORS
#
Ornt
Door Type
Storms
U-Value
Area
1
NE
Insulated
None
0.34
21.11111
2
NE
Insulated
None
0.34
21.11111
WINDOWS
Orientation shown is the entered, asBuilt orientation.
/
Overhang
v #
Ornt
Frame
Panes
NFRC
U-Factor
SHGC
Storms
Area
Depth
Separation
Int Shade
Screening
1
SW
Vinyl
Low-E Double
Yes
0.49
0.32
N 48.33333 3 ft 0 in
2 ft 0 in
HERS 2006
None
2
NW
Vinyl
Low-E Double
Yes
0.47
0.52
N
40 ft2
2 ft 0 in
2 ft 0 in
HERS 2006
None
3
SE
Vinyl
Low-E Double
Yes
0.47
0.52
N
24 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
4
NE
Vinyl
Low-E Double
Yes
0.47
0.52
N
160 ft2
11 ft 0 in
2 ft 0 in
HERS 2006
None
5
SE
Vinyl
Low-E Double
Yes
0.47
0.52
N
56 ft'
0 ft 0 in
0 ft 0 in
HERS 2006
None
6
NW
Vinyl
Low-E Double
Yes
0.47
0.52
N
102 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
7
SW
Vinyl
Low-E Double
Yes
0.47
0.52
N
12 ft2
2 ft 0 in
4 ft 0 in
HERS 2006
None
8
SW
Vinyl
Low-E Double
Yes
0.49
0.32
N
50 ft2
3 ft 0 in
2 ft 0 in
HERS 2006
None
9
SW
Vinyl
Low-E Double
Yes
0.47
0.52
N
24 ft2
2 ft 0 in
4 ft 0 in
HERS 2006
None
10
NE
Vinyl
Low-E Double
Yes
0.47
0.52
N
20 ft2
11 ft 0 in
2 ft 0 in
HERS 2006
None
11
NE
Vinyl
Low-E Double
Yes
0.45
0.61
N
24 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
12
SE
Vinyl
Low-E Double
Yes
0.47
0.52
N
24 ft2
0 ft 0-in
0 ft 0 in
HERS 2006
None
13
NW
Vinyl
Low-E Double
Yes
0.47
0.52
N
25 ft2
2 ft 0 in
2 ft 0 in
HERS 2006
None
14
SE
Vinyl
Low-E Double
Yes
0.47
0.52
N
25 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
15
SE
Vinyl
Low-E Double
Yes
0.47
0.52
N
25 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
16
SE
Vinyl
Low-E Double
Yes
0.47
0.52
N
15 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
17
SW
Vinyl
Low-E Double
Yes
0.47
0.52
N
15 ft2
2 ft 0 in
4 ft 0 in
HERS 2006
None
18
NW
Vinyl
Low-E Double
Yes
0.47
0.52
N
25 ft2
2 ft 0 in
2 ft 0 in
HERS 2006
None
19
SE
Vinyl
Low-E Double
Yes
0.47
0.52
N
25 ft2
0 ft 0 in
0 ft 0 in
HERS 2006
None
20
SW
Vinyl
Low-E Double
Yes
0.49
0.32
N 11.66666 3 ft 0 in
2 ft 0 in
HERS 2006
None
INFILTRATION & VENTING
--- Forced Ventilation ---- Run Time
Fan
Method
SLA
CFM 50
ACH 50
ELA
EgLA
Supply CFM
Exhaust CFM
Fraction
Watts
Default
0.00036
3441
4.72
188.9
355.2
0 cfm
0 cfm
0
0
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Ducts
1
Central Unit
Split
SEER: 14
55 kBtu/hr
cfm
0.85
sys#0
2 r
Central Unit
Split
SEER: 14
55 kBtu/hr
cfm
0.85
sys#0
8/13/2013 11:52 AM EnergyGauge® USA - FlaRes2008 Page 4 of 6
1
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity Ducts
1 Electric Strip Heat
None
COP: 1
28 kBtu/hr sys#0
2 Electric Strip Heat
None
COP: 1
25 kBtu/hr sys#0
HOT WATER SYSTEM
# System Type
EF Cap Use
SetPnt
Conservation
1 Electric
0.9 40 gal 50 gal
120 deg
None
2 Electric
0.9 40 gal 50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ---
— Return --
Air
Percent
V # Location R-Value
Area
Location
Area Leakage Type
Handler
CFM 25
Leakage
QN
RLF
1 Interior 6
847 ft2
Interior
847 ft2 Default Leakage
Interior
(Default)
(Default) %
2 Attic 6
753 ft2
Attic
753 ft2 Default Leakage
Interior
(Default)
(Default) %
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heating Jan Feb
M:y JunIx Jul
Aug
f X� Sep
�XjjXXj
j Mar
IX
IXj
dayj Jun j
r
rxi
�Xj Oct
�X� Nov
�Xj Dec
Venting X Jan X Feb
X Mar
Apr
Jun X Jul
Aug
IX Sep
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
66
66
8/13/2013 11:52 AM EnergyGauge® USA - FlaRes2008 Page 5 of 6
FORM 1100A-08
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: 53 Watersong Street PERMIT #:
St. Lucie County, FI,
INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
N1106.AB.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
N1106.AB.1.2
Caulk, gasket, weatherstrip or seal between: windows/doors &
frames, surrounding wall; foundation & wall sole or sill plate; joints
between exterior wall panels at corners; utility penetrations;
between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is
installed that extends from, and is sealed to, the foundation to the
top plate.
Floors
N1106.AB.1.2
Penetrations/openings > 1/8" sealed unless backed by truss or
joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier
is installed that is sealed to the perimeter, penetrations and seams.
Ceilings
N1106.AB.1.2
Between walls & ceilings; penetrations of ceiling plane to top floor;
around shafts, chases, soffits, chimneys, cabinets sealed to
continuous air barrier; gaps in gyp board & top plate; attic access.
EXCEPTION: Frame ceilings where a continuous infiltration barrier
is installed that is sealed at the perimeter, at penetrations and
seams.
Recessed Lighting Fixtures
N1106.AB.1.2
Type IC rated with no penetrations, sealed; or Type IC or non -IC
rated, installed inside a sealed box with 1/2" clearance & 3" from
insulation; or Type IC with < 2.0 cfm from conditioned space,
tested.
Multi -story Houses
N1106.AB.1.2
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
N1106.AB.1.3
Exhaust fans vented to outdoors, dampers; combustion space
heaters comply with NFPA, have combustion air.
OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
N1112.AB.3
Comply with efficiency requirements in Table N1112.ABC.3
Switch or clearly marked circuit breaker (electric) or cutoff (gas)
must be provided. External or built-in heat trap required.
Swimming Pools & Spas
N1112.AB.2.3
Spas & heated pools must have covers (except solar heated).
Non-commercial pools must have a pump timer. Gas spa & pool
heaters must have a minimum thermal efficiency of 78%.
Heat pump pool heaters shall have a minimum COP of 4.0.
Shower heads
N1112.AB.2.4
Water flow must be restricted to no more than 2.5 gallons per
minute at 80 PSIG.
Air Distribution Systems
N1110.AB
All ducts, fittings, mechanical equipment and plenum chambers
shall be mechanically attached, sealed, insulated and installed in
accordance with the criteria of Section N1110.AB.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
N1107.AB.2
Separate readily accessible manual or automatic thermostat for
each system.
Insulation
N1104.AB.1
Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both
N1102.B.1.1
sides. Common ceiling & floors R-11.
8/13/2013 11:52 AM EnergyGauge® USA - FlaRes2008 Page 6 of 6