HomeMy WebLinkAboutEnergy CalculationFORM 1100A-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs'Residential Performance Method A Project Name: Masterpiece -Doyle Builder Name: Sharkey Air LLC Street: 53 Watersong Street Permit Office: City, State, Zip: St. Lucie County, FI , Permit Number: Owner: Doyle Residence Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL 1. New construction or existing New (From Plans) 9. Wall Types (5120.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=19.0 4990.20 ft2 b. Concrete Block - Int Insul, Exterior R=19.0 130.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2247.0 sqft.) Insulation Area 6. Conditioned floor area (ft2) 3643.8333333333 a. Under Attic (Unvented) R=30.0 2247.00 ft2 b. N/A R= ft2 7. Windows(751.0 sqft.) Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.47 617.00 ft2 SHGC: SHGC=0.52 11. Ducts (combined) b. U-Factor: Dbl, U=0.49 110.00 ft2 a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 753 ft2 SHGC: SHGC=0.32 12. Cooling systems (combined) c. U-Factor: Dbl, U=0.45 24.00 ft2 a. Central Unit Cap: 110.0 kBtu/hr SHGC: SHGC=0.61 SEER:14 d. U-Factor: N/A ft2 13. Heating systems (combined) SHGC: a. Electric Strip Heat Cap: 53.0 kBtu/hr e. U-Factor: N/A ft2 COP: 1 SHGC: 8. Floor Types (3605.0 sqft.) Insulation Area ,� water systems Y' 1 ctric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 3605.0 EF: 0.9 b. N/A R= Conservation features c. N/A R= ft `.' None 15. Credits Pstat Total As -Built Modified Loads: 55.18 Glass/Floor Area: 0.206 PASS Total Baseline Loads: 69.85 I hereby certify that the plans and c er y Review of the plans and 1E ST, y Code. this calcu;Z70 specifications covered by this c Iculation indicates compliance PREPA with the Florida Energy Code.' Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 i * ,, I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy CV49dk OWNER/AGENT: e BUILDING OFFICIAL: DATE: - 3 0 - 13 DATE: 9/20/2013 2:27 PM EnergyGauge® USA - FlaRes2008 Page 1 of 6 T PROJECT Title: Masterpiece -Doyle Bedrooms: 4 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 3643.83333333333 Lot # Owner: Doyle Residence Total Stories: 3 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Sharkey Air LLC Rotate Angle: 0 Street: 53 Watersong Street Permit Office: Cross Ventilation: No County: St. Lucie County Jurisdiction: Whole House Fan: No City, State, Zip: St. Lucie County, Family Type: Single-family FI , New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90 75 70 722 58 Medium FLOORS # Floor Type Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 35 ft 0 360 ft2 1 0 0 2 Slab -On -Grade Edge Insulatio 1 ft 0 60 ft2 1 0 0 3 Slab -On -Grade Edge Insulatio 1 ft 0 1188 ft2 1 0 0 4 Slab -On -Grade Edge Insulatio 1 ft 0 56 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio 1 ft 0 54 ft2 1 0 0 6 Slab -On -Grade Edge Insulatio 36 ft 0 243 ft2 1 0 0 7 Slab -On -Grade Edge Insulatio 34 ft 0 289 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio 1 ft 0 289 ft2 1 0 0 9 Slab -On -Grade Edge Insulatio 24 ft 0 286 ft2 1 0 0 10 Slab -On -Grade Edge Insulatio 12 ft 0 72 ft2 1 0 0 11 Slab -On -Grade Edge Insulatio 18 ft 0 180 ft2 1 0 0 12 Slab -On -Grade Edge Insulatio 31 ft 0 196 ft2 1 0 0 13 Slab -On -Grade Edge Insulatio 27 ft 0 196 ft2 1 0 0 14 Slab -On -Grade Edge Insulatio 7 ft 0 136 ft2 1 0 0 ROOF Roof Gable Roof Solar Deck V # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Gable or Shed Metal 2368 ft2 374 ft2 Medium 0.96 No 0 18.4 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2247 ft2 N N 8/13/2013 11:52 AM EnergyGauge® USA - FlaRes2008 Page 2 of 6 CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) 39 360 ft2 0.1 Wood 2 Under Attic (Unvented) 39 243 ftZ 0.1 Wood 3 Under Attic (Unvented) 39 289 ftZ 0.1 Wood 4 Under Attic (Unvented) 39 289 ft2 0.1 Wood 5 Under Attic (Unvented) 39 286 ftz 0.1 Wood 6 Under Attic (Unvented) 39 72 ft2 0.1 Wood 7 Under Attic (Unvented) 39 180 ft2 0.1 Wood 8 Under Attic (Unvented) 39 196 ft2 0.1 Wood 9 Under Attic (Unvented) 39 196 ft2 0.1 Wood 10 Under Attic (Unvented) 39 136 ft2 0.1 Wood WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 SE Exterior Concrete Block - Ext Insul 19 150 ft2 0 0 0.8 2 SW Exterior Concrete Block - Ext Insul 19 70 ft2 0 0 0.8 3 NW . Exterior Concrete Block - Ext Insul 19 216 ft2 0 0 0.8 4 NE Exterior Concrete Block - Ext Insul 19 40 ft2 0 0 0.8 5 SE Exterior Concrete Block - Ext Insul 19 90 ft2 0 0 0.8 6 SE Exterior Concrete Block - Ext Insul 19 75 ft2 0 0 0.8 7 SE Exterior Concrete Block - Ext Insul 19 125 ft2 0 0 0.8 8 NE Exterior Concrete Block - Ext Insul 19 311.6666 0 0 0.8 9 SE Exterior Concrete Block - Ext Insul 19 420 ft2 0 0 0.8 10 NW Exterior Concrete Block - Ext Insul 19 750 ft2 0 0 0.8 11 SW Exterior Concrete Block - Ext Insul 19 84.16666 0 0 0.8 12 NW Exterior Concrete Block - Ext Insul 19 135 ft2 0 0 0.8 13 SE Exterior Concrete Block - Ext Insul 19 180 ft2 0 0 0.8 14 SW Exterior Concrete Block - Ext Insul 19 168.3333 0 0 0.8 15 NE Exterior Concrete Block - Ext Insul 19 90 ft2 0 0 0.8 16 SE Exterior Concrete Block - Ext Insul 19 337.5 ft2 0 0 0.8 17 NW Exterior Concrete Block - Ext Insul 19 150 ft2 0 0 0.8 18 NE Exterior Concrete Block - Ext Insul 19 170 ft2 0 0 0.8 19 NW Exterior Concrete Block - Ext Insul 19 212.5 ft2 0 0 0.8 20 SE Exterior Concrete Block - Ext Insul 19 150 ft2 0 0 0.8 21 NW Exterior Concrete Block - Ext Insul 19 150 ft2 0 0 0.8 22 SE Exterior Concrete Block - Ext Insul 19 150 ft2 0 0 0.8 23 SE Exterior Concrete Block - Ext Insul 19 225 ft2 0 0 0.8 24 SE Exterior Concrete Block - Ext Insul 19 50 ft2 0 0 0.8 25 SW Exterior Concrete Block - Ext Insul 19 140 ft2 0 0 0.8 26 NW Exterior Concrete Block - Ext Insul 19 150 ft2 0 0 0.8 27 SE Exterior Concrete Block - Ext Insul 19 200 ft2 0 0 0.8 28 SW Exterior Concrete Block - Int Insul 19 130 ft2 0 0 0.8 8/13/2013 11:52 AM EnergyGaugeO USA - FlaRes2008 Page 3 of 6 DOORS # Ornt Door Type Storms U-Value Area 1 NE Insulated None 0.34 21.11111 2 NE Insulated None 0.34 21.11111 WINDOWS Orientation shown is the entered, asBuilt orientation. / Overhang v # Ornt Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 SW Vinyl Low-E Double Yes 0.49 0.32 N 48.33333 3 ft 0 in 2 ft 0 in HERS 2006 None 2 NW Vinyl Low-E Double Yes 0.47 0.52 N 40 ft2 2 ft 0 in 2 ft 0 in HERS 2006 None 3 SE Vinyl Low-E Double Yes 0.47 0.52 N 24 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 4 NE Vinyl Low-E Double Yes 0.47 0.52 N 160 ft2 11 ft 0 in 2 ft 0 in HERS 2006 None 5 SE Vinyl Low-E Double Yes 0.47 0.52 N 56 ft' 0 ft 0 in 0 ft 0 in HERS 2006 None 6 NW Vinyl Low-E Double Yes 0.47 0.52 N 102 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 7 SW Vinyl Low-E Double Yes 0.47 0.52 N 12 ft2 2 ft 0 in 4 ft 0 in HERS 2006 None 8 SW Vinyl Low-E Double Yes 0.49 0.32 N 50 ft2 3 ft 0 in 2 ft 0 in HERS 2006 None 9 SW Vinyl Low-E Double Yes 0.47 0.52 N 24 ft2 2 ft 0 in 4 ft 0 in HERS 2006 None 10 NE Vinyl Low-E Double Yes 0.47 0.52 N 20 ft2 11 ft 0 in 2 ft 0 in HERS 2006 None 11 NE Vinyl Low-E Double Yes 0.45 0.61 N 24 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 12 SE Vinyl Low-E Double Yes 0.47 0.52 N 24 ft2 0 ft 0-in 0 ft 0 in HERS 2006 None 13 NW Vinyl Low-E Double Yes 0.47 0.52 N 25 ft2 2 ft 0 in 2 ft 0 in HERS 2006 None 14 SE Vinyl Low-E Double Yes 0.47 0.52 N 25 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 15 SE Vinyl Low-E Double Yes 0.47 0.52 N 25 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 16 SE Vinyl Low-E Double Yes 0.47 0.52 N 15 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 17 SW Vinyl Low-E Double Yes 0.47 0.52 N 15 ft2 2 ft 0 in 4 ft 0 in HERS 2006 None 18 NW Vinyl Low-E Double Yes 0.47 0.52 N 25 ft2 2 ft 0 in 2 ft 0 in HERS 2006 None 19 SE Vinyl Low-E Double Yes 0.47 0.52 N 25 ft2 0 ft 0 in 0 ft 0 in HERS 2006 None 20 SW Vinyl Low-E Double Yes 0.49 0.32 N 11.66666 3 ft 0 in 2 ft 0 in HERS 2006 None INFILTRATION & VENTING --- Forced Ventilation ---- Run Time Fan Method SLA CFM 50 ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction Watts Default 0.00036 3441 4.72 188.9 355.2 0 cfm 0 cfm 0 0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit Split SEER: 14 55 kBtu/hr cfm 0.85 sys#0 2 r Central Unit Split SEER: 14 55 kBtu/hr cfm 0.85 sys#0 8/13/2013 11:52 AM EnergyGauge® USA - FlaRes2008 Page 4 of 6 1 HEATING SYSTEM # System Type Subtype Efficiency Capacity Ducts 1 Electric Strip Heat None COP: 1 28 kBtu/hr sys#0 2 Electric Strip Heat None COP: 1 25 kBtu/hr sys#0 HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation 1 Electric 0.9 40 gal 50 gal 120 deg None 2 Electric 0.9 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply --- — Return -- Air Percent V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Interior 6 847 ft2 Interior 847 ft2 Default Leakage Interior (Default) (Default) % 2 Attic 6 753 ft2 Attic 753 ft2 Default Leakage Interior (Default) (Default) % TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating Jan Feb M:y JunIx Jul Aug f X� Sep �XjjXXj j Mar IX IXj dayj Jun j r rxi �Xj Oct �X� Nov �Xj Dec Venting X Jan X Feb X Mar Apr Jun X Jul Aug IX Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/13/2013 11:52 AM EnergyGauge® USA - FlaRes2008 Page 5 of 6 FORM 1100A-08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 53 Watersong Street PERMIT #: St. Lucie County, FI, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi -story Houses N1106.AB.1.2 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N1112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.B.1.1 sides. Common ceiling & floors R-11. 8/13/2013 11:52 AM EnergyGauge® USA - FlaRes2008 Page 6 of 6