Loading...
HomeMy WebLinkAboutTruss Wind Load Compliance (2) 05/23/2066 14:05 7724621735 ST HJCTE Cn PAGE 01: St. Lucre.'Ccun``r : 7 Building and Zoning Department 2300 Virginia•Avenue Pout Pieme','L 34982 Design Celrtifiication•.for.Wind:Load CompllanceJ. TAS Certification is to be completed by the project'desigti'aicbiteet,ar engineer: Tbis Certificatirta mast be submitted with all ' aep llcations for building permits involvint'the construction of new residence(s'ingle or multi-family),n►sidential,addiiion,any. accessory structure requiring a building i ermit,and any nonresidential structure:,This Certtfication:shall,not applyi a Interior renovations(provided that no structtiral-.walls,colurrihs or-othei t6iW component is beingeffected)And certain other-'minor building permits. For further assist#nce,please.contact the Building lnspestipn Office-at 462,-M3 or 4624t?2.. r Pro'ectName 1� NC7 M OfficeElRe,0h StreerAddre 4933 W 'fERSoNG.WA Penhitxumher s FY l V Ucca e ,3--SFl-1: - - ".Construction •, - certification Sialetnent: L ;.. i certify that,to the best of my kri,owlledge and.belief,these plans and spe4 icatioins•liaue-been'designcd to- comply with the applicable structural portion of-the Building:Codes-cvrres tt -ildopted and'enforced•by St.Lucie County: L also certify-that staictural kirtetf9 depicted-on these plans proiii&ad 6ti:iesistance to the wind loads and forces specified by current code provisions. Deshm Parameters and Assumptions Used; (Please check or complete tlte;appropriate,box.) 1.FCfida Building;Cede 2884 Edit 1f If�SCE'T=98r' 2. itng.BuildDesign .is.(checLow) Enclosed ✓ Partialty.Enclosed'•. Opetr Burning- , � . ,: ...r. ;;'• 3.Building Height: dot-�o r 4.Wind-Speed.-Used-in._Uset�in.Buildift Desig®: J!3 second geest ;,`Sh,Wiod Exposure Classification!(refer to•exposure tables in, uilding'Codc.identiied in Line 0)1): 33.3 PSF Avexagt Wind Velotity.Pmsuu'on-�R.xteirio r.Faceao€'Strsctafe` - 3,.Peak Wind Velocity Pressure on Exterier 1Faces of Structnre. 8.Importance/Use Factor(obtain from Building Code): 0.Loader. Floor. PSF RooUdead ,2 P5F Reegfive3 O PSF 10,Were-Shear.Walls.Considered-for Stsuctare(cbectcone): Yes, y" No ' •WNe,attmeb explanatioa. I1.Is a Continuous Load Path Provided(check one): Yes_Y"' No (if No,ettach explsnatnon) 12.Are Component and Cladding Detail Provided(check one):Yes No (if No,atttich explanation) M Minimum Soil.Bearing.Pressure;,.-�PSII' As witnessed by my seal,I hereby eertifythatthe-ihfermafion includedtvitb this certification is true and correct,to the.best of my knowledge and belief; Name: Certification.#: 20.311 [Seal Here)• Design Film: JAMES bU9400 e, f M . D_ ate: 1.2/0 , r. SLCCDV Form 9 02010, ;;.Lo/ l