HomeMy WebLinkAboutEngineeringA. M. ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST. LUCiE, FLORIDA 34986 (772) 924-3575 OFFICE - (772) 924-3580 FAX November 7, 2007 Bodax Foundation, Inc. 1101 NW 55th Street Ft. Lauderdale, Florida 33309 Re: Auger -Cast Pile Installation for Phillips Residence Lot 9, Watersong Way, Hutchinson Island, Florida Project No. 1654-4 Ladies and Gentlemen: A. M. Engineering and Testing, Inc. is pleased to submit this report of our pile installation monitoring for the referenced project. A representative of A. M. Engineering was present on site on November 5 and 6, 2007, to observe the installation of 31 augered cast -in -place piles. Logs were kept of the pertinent information and are enclosed. The pile identification numbers noted on the logs correspond to the numbers indicated on the enclosed pile layout plan. The number of "Required Strokes" was determined by measuring the pump strokes needed to fill a container of known volume. The pump calibration indicated that 18 pump strokes were needed to fill 7.35 cubic feet. The strokes necessary to fill the theoretical volume plus 10% were then calculated to determine the required strokes for the individual piles. The pile lengths noted on the logs are based on the depths below the existing ground surface at the time that the piles were installed. The project site was relatively flat and approximately even with the adjacent road. The working grade was approximately elevation 6 feet NGVD based on survey stakes. The monitored piles had grout takes at least 10% in excess of their theoretical volume. Placement of the reinforcing steel for the piles was also monitored. The steel reinforcing was constructed and placed in substantial compliance with the provided plans. The steel reinforcing consisted of five 38-foot #6 vertical bars with #3 ties @ 12" on center. Concrete grout cubes were made for each 50 cubic yards of grout placed. A total of two sets of cubes were molded. The results will be submitted under separate cover. A. M. ENGINEERING AND TESTING, INC. Summary of Pile Installation Lot 9, Watersong Way, Hutchinsong Island, Florida Project No. 1654-4 A. M. Engineering and Testing, Inc. has appreciated the opportunity to assist you with this phase of your project. If you have any questions regarding this report or need any further information, please call us. Respectfully submitted, A. M. ENGINEERING AND TESTING, INC. Staff Engineer RGA/RM Attachments: Pile Monitoring Logs (3 Pages) Pile Layout Drawings (1) Copies: Client - 2 R becca Gran Asc li. •P. Senior Geotecluiical Fngirieer Florida Registration No. 51.863_ , IlServer-amelcompanyL4M DatalBodax Foundations, Inc. -Various - 16541Lot 9, Watersong Way, Hutchinson IslandlPile Installation Report.doc PJ A. M. ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 (772) 924-3575 Fax (772) 924-3580 AUGER CAST PILE LOG Client: Bodax Foundations, Inc. Grout: 5000 psi Mix #1339756 General Contractor: Pile Diameter: 16 Inches Pile Contractor: Bodax Foundations, Inc. Technician: R. Merlihan Site: Lot 9, Watersong Way, Hutchinson Island St. Lucie County, Florida Project No: Lab No.: 1654 4 Date Time Pile No. Pile Depth (feet) Required Pump Strokes Actual Pump Strokes I Ticket No. Truck No. Cubic Yards Time Batched Set No. Steel In? 11/5/07 9:34 1 36 136 157 94909904 10026088 9 9:16 Y 10:00 2 36 136 139 Y 10:10 3 36 136 137 Y 10:37 4 36 136 161 94910113 10022645 9/18 10:01 Y 10:48 5 36 136 138 It it to1 Y 10:58 6 36 136 136 It it toY 11:05 7 36 136 156 94910253 10025309 9/27 10:28 Y 11:15 8 36 136 165 it it 11 ifY 11:25 9 36 136 142 it if 11 itY 11:40 10 36 136 150 94910425 10026088 9/36 11:07 Y 11:51 11 36 136 145 11 it 11 11Y 12:07 12 36 136 145 to If if 11Y 12:16 13 36 136 136 94910566 10022645 9/45 11:41 Y 12:26 14 36 136 135 Y 12:36 15 36 136 161 Y 1:23 16 36 136 143 94910796 10018421 9/54 12:43 Y IlServer-amelcompanyL4M DatalBodax Foundations, Inc. -Various - 16541Lot 9, Watersong Way, Hutchinson Island14 -Auger cast Pile Logs.doc Page 1 of 3 A. M. ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 (772) 924-3575 Fax (772) 924-3580 AUGER CAST PILE LOG Client: Bodax Foundations, Inc. Grout: 5000 psi Mix #1339756 General Contractor: Pile Diameter: 16 Inches Pile Contractor: Bodax Foundations, Inc. Technician: R. Merlihan Site: Lot 9, Watersong Way, Hutchinson Island St. Lucie County, Florida Project No: Lab No.: 1654 4 Date Time Pile No. Pile Depth (feet) Required Pump Strokes Actual Pump Strokes Ticket No. Truck No. Cubic Yards Time Batched Set No. Steel In? 11/5/07 1:33 17 36 136 137 94910796 10018421 9/54 12:43 Y 1:42 18 36 136 135 Y Pile 18: The placement of the steel cage was very difficult. Steel cage was left approximately 7 feet above ground surface. IlServer-atnelcompanylAMData lBodax Foundations, Inc. - Various-16541Lot 9, Watersong Way, Hutchinson Island14 - Auger cast Pile Logs.doc Page 2 of 3 A. M. ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 (772) 924-3575 Fax (772) 924-3580 AUGER CAST PILE LOG Client: Bodax Foundations, Inc. Grout: 5000 psi Mix #1339756 General Contractor: Pile Diameter: 16 Inches Pile Contractor: Bodax Foundations, Inc. Technician: R. Merlihan Site: Lot 9, Watersong Way, Hutchinson Island St. Lucie County, Florida Project No: Lab No.: 1654 4 Date Time Pile No. Pile Depth (feet) Required Pump Strokes Actual Pump Strokes Ticket No. Truck No. Cubic Yards Time Batched Set No. Steel In? 11/6/07 8:32 19 36 136 140 87455796* 18101 9 7:30 Y 8:45 20 36 136 145 if of it 112 Y 8:55 21 36 136 138 it if it itY 9:20 22 36 136 142 it2094 9/18 8:38 Y 9:30 23 36 136 138 87455801* If it ifY 9:39 24 36 136 149 it of It ifY 10:13 25 36 136 140 87455806* 6088 9/27 9:24 Y 10:22 26 36 136 147 of 11 11Y 10:30 27 36 136 142 it 11 ifY 11:30 28 36 136 144 87455812* 6433 9/36 10:31 Y 11:42 29 36 136 140 it 11 11 itY 11:53 30 36 136 139 Y 12:37 31 36 136 135 87455819* 2366 4/40 11:43 Y * Receipt number from the upper right corner of delivery sheet. Pile numbers 23, 27 and 29: The steel cage left approximately 4 feet above ground surface. I IServer-amelcompanylAM Data lBodax Foundations, Inc. - Various-16541Lot 9, Watersang Way, Hutchinson Islandl4 - Auger cast Pile Logs.doc Page 3 of 3