Loading...
HomeMy WebLinkAboutFlorida Energy Efficiency Codei 10 FORM OA-2004R EnergyGauge@ 4.5 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FloridaDepartment Depae"t u4: Community Affairs 10 Residential Whole Building Performance Method A Project Name: PHILLIPS Builder: Address: LOT 9, WATERSONG Permitting Office: City, State: HUTCHINSON ISLAND, FL Permit Number: Owner: Jurisdiction Number: Climate Zone: Central 1. New construction or existing New 12. Cooling systems 2. Single family or multi -family Single family a. Central Unit Cap: 49.0 kBtu/hr - 3. Number of units, if multi -family I SEER: 14.00 - 4. Number of Bedrooms 3 b. Central Unit Cap: 29.6 kBtu/hr - 5. Is this a worst case? Yes SEER: 14.00 6. Conditioned floor area (ft2) 2981 ft2 c. N/A 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sngle Default) 423.0 ft2 a. Electric Heat Pump Cap: 34.3 kBtu/hr b. SHGC: HSPF: 8.10 (or Clear or Tint DEFAULT) 7b. (Tint) 423.0 ft2 b. Electric Heat Pump Cap: 18.2 kBtu/hr 8. Floor types HSPF: 8.50 a. Raised Wood R=I 1.0, 159.0 ft2 c. N/A b. Slab -On -Grade Edge Insulation, 0 R--O.O, 158.0 ft2 c. I Others 152.0 ft2 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 50.0 gallons a. Concrete, Int Insul, Exterior R=4.1, 2090.0 ft2 EF: 0.97 b. Frame, Wood, Adjacent R=1 1.0, 261.0 ft2 b. N/A c. N/A d. N/A c. Conservation credits e. N/A (HR-Heat recovery, Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=20.0, 1491.0 ft2 15. HVAC credits MZ-C, PT, b. Under Attic R=20.0, 1154.0 ft2 (CF-Ceiling fan, CV -Cross ventilation, c. N/A HF-Who'le house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AH: Interior Sup. R=6.0, 146.0 ft MZ-C-Multizone cooling, b. Sup: Unc. Ret: Unc. AH: Attic Sup. R=6.0, 132.0 ft MZ-H-Multizone heating) Glass/Floor Area: 0.14 Total as -built points: 32302 PASS Total base points: 33025 I hereby certify that the plans and specifications; co re , Y� specifications covered by this Review of the plans and O%En S �r g I A y this calculation are in compliancewith the Florida E-nel 0 Code. 0;mEs-E 3 # 5�o calculation indicates compliance 9 PREPARED By. R,�! with the Florida Energy Code. ... . .. DATE: 031 OA Before construction is completed this building will be inspected for I hereby certify that this build' as designed, is in compliance compliance with Section 553.908 with the Florida Energy e. Florida Statutes. vBUILDING h wig ey OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge@ (Version: FLRCSB v4.5) ENERGY PERFORMANCE LEVEL (EPL), DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 86.4 The higher the score, the more efficient the home. , LOT 9, WATERSONG, HUTCHINSON ISLAND, FL, 1. New construction or existing New 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 4. Number of Bedrooms 3 5. Is this a worst case? Yes 6. Conditioned floor area (ft2) 2981 ft2 7. Glass type and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 423.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7V. (Tint) 423.0 ft2 8. Floor types a. Raised Wood R=11.0, 159.0 ft2 b. Slab -On -Grade Edge Insulation, 0 R=0.0, 158.0 ft2 c. I Others 152.0 ft2 9. Wall types a. Concrete, Int Insul, Exterior R=4.1, 2090.0 ft2 b. Frame, Wood, Adjacent R=11.0, 261.0 ft2 c. N/A d. N/A - e. N/A 10. Ceiling types a. Under Attic R=20.0, 149 1. 0 ft2 b. Under Attic R=20.0, 1154.0 ft2 c. N/A 11. Ducts a. Sup: Unc. Ret: Unc. AH: Interior Sup. R=6.0, 146.0 ft b. Sup: Unc. Ret: Unc. AH: Attic Sup. R=6.0, 132.0 ft 12. Cooling systems a. Central Unit Cap: 49.0 kBtu/hr _ SEER: 14.00 _ b. Central Unit Cap: 29.6 kBtu/hr SEER: 14.00 c. N/A 13. Heating systems _ a. Electric Heat Pump Cap: 34.3 kBtu/hr HSPF: 8.10 _ b. Electric Heat Pump Cap: 18.2.kBtu/hr _ HSPF:8.50 _ c. N/A 14. Hot water systems a. Electric Resistance Cap: 50.0 gallons _ _ EF: 0.97 _ b. N/A _ c. Conservation credits _ _ (HR-Heat recovery, Solar DHP-Dedicated heat pump) _ 15. HVAC credits MZ-C, PT, _ (CF-Ceiling fan, CV -Cross ventilation, _ HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) .y0�� uE s in this home before final ins ection. Otherwise, a new EPL Display Card will be completed based on installed G, =copliant fe Builder Signature: Date- 'U ! Address of New Home: gt3 c? N9 City/FL Zip: �i 20 WF *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarr"'designation), your home may qualms for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating. L.ontact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec.ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building 'Construction, contact the Department of Community Affairs at 8501487-1824. '1 Predominant glass type. For actual glass type and areas see Summer & Winter Glass out ut on ages 2&4. K; ergyGauge® (Version: FERMIN v4.5) FORM 60OA-2004R EnergyGauge@ 4.5 M 1 - SUMMER CALCULATIONS -, - Residential Whole Building. Performance Method A - Details ADDRESS: LOT 9, WATERSONG, HUTCHINSON ISLAND, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 2981.0 24.35 13066.0 1.Single, Tint N 2.0 5.0 60.0 24.46 0.88 1284.0 2.Single, Tint E 2.0 6.0 32.0 53.27 0.85 1457.0 3.Single, Tint E 6.0 4.0 24.0 53.27 0.44 566.0 4.Single, Tint S 2.0 6.0 32.0 39.84 0.80 1017.0 5.Single, Tint W 5.0 4.0 12.0 47.90 0.49 283.0 6.Single, Tint E 2.0 5.0 40.0 53.27 0.81 1716.0 7.Single, Tint E 8.0 5.0 30.0 53.27 0.43 687.0 8.Single, Tint S 8.0 4.0 24.0 39.84 0.50 474.0 9.Single, Tint S 2.0 7.0 18.0 39.84 0.84 600.0 10.Single, Tint W 3.0 4.0 24.0 47.90 0.62 707.0 11.Single, Tint W 2.0 5.0 20.0 47.90 0.81 771.0 12.Single, Tint E 2.0 6.0 16.0 53.27 0.85 728.0 13.Single, Tint E 2.0 5.0 25.0 53.27 0.81 1073.0 14.Single, Tint S 8.0 4.0 24.0 39.84 0.50 474.0 15.Single, Tint W 2.0 7.0 18.0 47.90 0.89 767.0 16.Single, Tint W 2.0 4.0 24.0 47.90 0.74 849.0 As -Built Total: 423.0 13453.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 261.0 0.70 182.7 1. Concrete, Int Insul, Exterior 4.1 2090.0 1.18 2466.2 Exterior 2090.0 1.90 3971.0 2. Frame, Wood, Adjacent 11.0 261.0 0.70 182.7 Base Total: 2361.0 4153.7 As -Built Total: 2351.0 2648.9 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 128.0 4.80 614.4 Exterior 272.0 4.80 1305.6 2.Exterior Insulated 72.0 4.80 345.6 3.Exterior Insulated 40.0 4.80 192.0 4.Exterior Insulated 32.0 4.80 153.6 Base Total: 272.0 1305.6 As -Built Total: 272.0 1305.6 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 2246.0 2.13 4784.0 1. Under Attic 20.0 1491.0 2.73 X 1.00 4070.4 2. Under Attic 30.0 1154.0 2.13 X 1.00 2458.0 Base Total: 2246.0 4784.0 As -Built Total: 2645.0 6528.5 EnergyGauge@ DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details 4 y ADDRESS: LOT 9, WATERSONG, HUTCHINSON ISLAND, FL, PERMIT #: BASE AS -BUILT FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 158.0(p) -31.8-5024.4 1. Slab -On -Grade Edge Insulation 0.0 158.0(p -31.90 -5040.2 Raised 311.0 -3.43-1066.7 2. Raised Wood, Adjacent 11.0 159.0 1.80 286.2 3. Raised Wood, Adjacent 11.0 152.0 1.80 273.6 Base Total: -6091.1 As -Built Total: 469.0 -4480.4 INFILTRATION Area X BSPM = Points Area X SPM = Points 2981.0 14.31 42658.1 2981.0 14.31 42658.1 Summer Base Points: 59876.3 Summer As -Built Points: 62113.7 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 49000btuh ,SEER/EFF(14.0) Ducts: Unc(S), Unc(R), Int(AH),R6.0(INS) 62114 0.62 (1.09 x 1.150 x 0.85) 0.244 0.902 9097.6 (sys 2: Central Unit 29600btuh ,SEER/EFF(l4.0) Ducts: Unc(S),Unc(R),Att(AH),R6.0(INS) 62114 0.38 (1.09 x 1.150 x 1.10) 0.244 0.902 7070.5 59876.3 0.3250 19459.8 62113.7 1.00 1.214 0.244 0.902 16578.9 Is A EnergyGaugeTh4 DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 WINTER CALCULATIONS - Residential Whole Building Performance Method A - Details ADDRESS: LOT 9, WATERSONG, HUTCHINSON ISLAND, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 2981.0 9.11 4888.0 1.Single, Tint N 2.0 5.0 60.0 15.38 0.99. 918.0 2.Single, Tint E 2.0 6.0 32.0 13.04 1.03 429.0 3.Single, Tint E 6.0 4.0 24.0 13.04 1.24 386.0 4.Single, Tint S 2.0 6.0 32.0 10.88 1.12 388.0 5.Single, Tint W 5.0 4.0 12.0 13.80 1.10 181.0 6.Single, Tint E 2.0 5.0 40.0 13.04 1.04 543.0 7.Single, Tint E 8.0 5.0 30.0 13.04 1.25 488.0 8.Single, Tint S 8.0 4.0 24.0 10.88 2.22 579.0 9.Single, Tint S 2.0 7.0 18.0 10.88 1.08 210.0 10.Single, Tint W 3.0 4.0 24.0 13.80 1.07 354.0 11.Single, Tint W 2.0 5.0 20.0 13.80 1.03 284.0 12.Single, Tint E 2.0 6.0 16.0 13.04 1.03 214.0 13.Single, Tint E 2.0 5.0 25.0 13.04 1.04 339.0 14.Single, Tint S 8.0 4.0 24.0 10.88 2.22 579.0 15.Single, Tint W 2.0 7.0 18.0 13.80 1.02 252.0 16.Single, Tint W 2.0 4.0 24.0 13.80 1.04 345.0 As -Built Total: 423.0 6489.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 261.0 1.80 469.8 1. Concrete, Int Insul, Exterior 4.1 2090.0 3.31 6907.5 Exterior 2090.0 2.00 4180.0 2. Frame, Wood, Adjacent 11.0 261.0 1.80 469.8 Base Total: 2361.0 4649.8 As -Built Total: 2351.0 7377.3 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 128.0 5.10 652.8 Exterior 272.0 5.10 1387.2 2.Exterior Insulated 72.0 5.10 367.2 3.Exterior Insulated 40.0 5.10 204.0 4.Exterior Insulated 32.0 5.10 163.2 Base Total: 272.0 1387.2 As -Built Total: 272.0 1387.2 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 2246.0 0.64 1437.4 1. Under Attic 20.0 1491.0 0.84 X 1.00 1252.4 2. Under Attic 30.0 1154.0 0.64 X 1.00 738.6 Base Total: 2246.0 1437.4 1 As -Built Total: 2645.0 1991.0 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge@ 4.5 WINTER CALCULATIONS • - Residential Whole Building Performance Method A - Details ADDRESS: LOT 9, WATERSONG, HUTCHINSON ISLAND, FL, PERMIT #: x BASE AS -BUILT FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 158.0(p) -1.9 -300.2 1. Slab -On -Grade Edge Insulation 0.0 158.0(p 2.50 395.0 Raised 311.0 -0.20 -62.2 2. Raised Wood, Adjacent 11.0 159.0 1.80 286.2 3. Raised Wood, Adjacent 11.0 152.0 1.80 273.6 Base Total: -362.4 As -Built Total: 469.0 964.8 INFILTRATION Area X BWPM = Points Area X WPM = Points 2981.0 -0.28 -834.7 2981.0 -0.28 -834.7 Winter Base Points: 11165.4 Winter As -Built Points: 17364.E Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 34300 btuh ,EFF(8.1) Ducts:Unc(S),Unc(R),Int(AH),R6.0 17364.6 , 0.653 (1.078 x 1.160 x 0.87) 0.421 0.950 4963.2 (sys 2: Electric Heat Pump 18200 btuh ,EFF(8.5) Ducts: Unc(S),Unc(R),Att(AH),R6.0 17364.6 0.347 (1.078 x 1.160 x 1.11) 0.402 0.950 3187.3 11166.4 0.5540 6185.6 17364.6 1.00 1.233 0.414 0.950 8426.5 EnergyGaugeTM' DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 Code Compliance Checklist • Residential Whole Building Performance Method A - Details ADDRESS: LOT 9, WATERSONG, HUTCHINSON ISLAND, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1 /2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 Project Summary Entire House For: PHILLIPS Notes: ZONE 1 & 2 Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 92801 Btuh Ducts 7484 cfm Central vent (46 cfm) 1414 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 101699 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ftz) 1774 1774 Volume (ft3) 18374 18374 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 116 61 Heating Equipment Summary Make Trade Model Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.1 HSPF 45500 Btuh @ 47°F 25 OF 1633 cfm 0.016 cfm/Btuh 0.00 in H2O Job: Date: May 04, 2007 By: Summer Design Conditions Outside db 90 OF Inside db Design TD Daily range Relative Humidity Moisture difference 75 15 L 50 61 OF OF % gr/lb Sensible Cooling Equipment Load Sizing Structure 26106 Btuh Ducts 9252 Btuh Central vent (46 cfm) 757 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 34309 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2933 Btuh Central vent (46 cfm) 1919 Btuh Equipment latent load 7810 Btuh Equipment total load 42120 Btuh Req. total capacity at 0.70 SHR 4.1 ton Cooling Equipment Summary Make Trade Cond Coil Efficiency 13.5 SEER Sensible cooling 34300 Btuh Latent cooling 14700 Btuh Total cooling 49000 Btuh Actual air flow 1633 cfm Air flow factor 0.046 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.82 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. vvrightSc3 t Right -Suite Residential6.0.27 RSR30402 2007-Aug-27 11:55:29 ACCK CAMy Documents\Wrightsoft HVAC\phil1ips1.rrp Cale = NIJ8 Orientation = N Page 1 Short Form Job: Date: May 04, 2007 Entire House By: 1�7 Projgct Information Design Information Htg Clg Infiltration Outside db (°F) 42 90 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (OF) 28 15 Fireplaces 0 Daily range - L Inside humidity (%) - 50 Moisture difference (gr/lb) - 61 HEATING EQUIPMENT Make Trade Model Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.1 HSPF 45500 Btuh @ 47°F 25 OF 1633 cfm 0.016 cfm/Btuh 0.00 in H2O COOLING EQUIPMENT , Make Trade Cond Coil Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 13.5 SEER 34300 Btuh 14700 Btuh 49000 Btuh 1633 cfm 0.046 cfm/Btuh 0.00 in H2O 0.82 ROOM NAME Area (ffz) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) foyer 266 13085 2983 213 138 storage 369 21131 5712 344 264 family 259 18373 8787 299 406 breakfast 94 5822 2044 95 94 kitchen 217 10758 4626 175 214 laund-stair-hall 137 6638 2574 108 119 dining 159 10654 4275 173 197 powder 35 1472 107 24 5 bdrm 189 9767 3300 159 152 ho+h AA 'MOA ncn An AA s Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrightSoflt Right -Suite Residential 6.0.27 RSR30402 2007-Aug-27 11:55:28 ACa C:\My Documents\Wrightsoft HVAC\phillipsl.rrp Calc = MJ8 Orientation = N Page 1 Entire House 1774 100285 35358 1633 1633 Other equip loads 1414 757 Equip. @ 0.95 RSM 34309 Latent cooling 7810 TIITAI O 477A Aft 4GfV1 A114 nf% 4G09 4G94 = Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right -Suite Residential6.0.27 RSR30402 2007-Aug-27 11:55:28 ACC& CAMy Documentsxwrightsoft HVAClphillipsl.rrp Calc = MJ8 Orientation = N Page 2 • Right-J Worksheet Entire House Job: Date: May 04, 2007 By: 1 Room name Entire House foyer 2 Exposed wall 1740.0 ft 266.0 ft 3 Ceiling height 10.4 ft 10.0 ft heat/cool 4 Room dimensions 18.9 x 14.1 ft 5 Room area 1773.9 W 266.5 ft' Ty Construction U-value Or HTM Area (ft� Load Area (W) Load number (13tuh/ft' °F) (13 /ft� or perimeter (ft) (13tuh) or perimeter (ft) (13tuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 n 4.00 2.55 542 320 1281 815 0 0 0 0 1A-hlom' 1.270 n 35.56 27.56 138 0 4907 3807 - 0 6 0 0 1A-hlom 1.270 n 35.56 29.95 60 0 2134 1797: 0 0 0 6 10A-m: 1.670 n 46.76 .25.31 24 0. 1122 608 0. 0 0: 0 IW L�G 11 13A-4ocs 0.143 a 4.00 2.55 340 292 1169 743 0 0 0 0 IA-hlom 1.270 a 35.56 69.02 24 0 853 1656 0 0 0 0 G 1CA-m 1.670 a 46.76 53.19 24 24 1122 608 0 0 0 0 13A-4ocs : 0.143 s '4.00 2.55 258 170 681 433' 0 0 0 0 1A-hlom 1.270 s 35.56 32.10 20 20 711 599 0 : 0 . 0 0 TEG 10A-rn 1.670 s 46.76,,-, 26.85 36 36 1683 911 0 0 . 0 0 1A-hlom 1.270 s 35.56 32.10 32 32 1138 958' 0 0 0 0' W 13A-4ocs 0.143 w 4.00 2.56 693 643 2575 1637 189 179 717 456 L-G P C 1A-hlom 1213-0bm 16A-30md 1.270 ,0.122 0.032 . w 35.56 3!42 0.90 69.02 1:07 2.32 50, 92 1774 0 92 1774 .1778 314 1589 3451 : 99 4115 10 92 266 0 . 92 266 356 314, 239 690 99: 618 F' 22A-tph. 1.358 - 38.02: .:0:00 1774 1740 66162 0 266' 266 10114 0 6 c) AED excursion 0 235 Envelope loss/gain 89220 22236 11740 2098 12 a) Infiltration b) Room ventilation 3581 0 1010 0 369 0 104 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances @ 1200 2 2400 0 0 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 0 0 0 0 14 15 Subtotal Duct loads 8% 35% 92801 7484 26106 9252 8% 35% 12109 977 2202 780 Total room load Air required (cfm) I i 100285 1633 35358 1633 13085 213 2983 138 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ,� wr�ghtsoft Right -Suite Residential6.0.27 RSR30402 2007-Aug-27 11:55:29 ACC C:\My Documents\Wrightsoft HVAC\phillipst.rrp Calc= MJ8 Orientation = N Page 1 Right-J Worksheet Job: a t Entire House Date: May 04, 2007 By: 1 Room name storage family 2 Exposed wall 369.0 ft 259.0 ft 3 Ceiling height 10.0 ft heat/cool 11.0 ft hea/cool 4 Room dimensions 25.3 x 14.6 ft 15.4 x 16.8 ft 5 Room area 369.4 ftz 258.7 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (f:5 Load number (Btuh/W °F) (Btuh/ft5 or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 W 13A-4ocs 0.143 n 4.00 2.55 253 161 645 416 185 95 380 242 A- 1h1om 1.270 n 35.56 27.58 8 0 284 221 90 6 3200 2483'. LLL-----GGG 1A-hlom 1.270 n 5612 29.95 60 0 2134 1797 0 0. 0 0 10A-m 1.670 n .. 46.76 25.31, 24. 0 1122 . ° ° . 608 0 0 0 . 0 W. G 11 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 -24 -96 -61 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 LG 10A-m 1.670 a 46.76 53.19 0 0 0 0 24 24 1122 608 .vh13A flocs 0.143 s 4.00 2.55 0 -12 48 -31 0 0 0 IA-hlom 1.270 s 35.66 32.10 0 0 6 0 0 0 0 0 10A-m 1.670 s 46.76 - 26.85 12 12 561' 304 0 0 0 0 W 1A-hlom.. 13A-4 cs 1.270 0.143 s w 35.56.. 4.00 32.10 2.55 0 0 0, 0 0 0 0 0 0 169 0 139 0 557 0 354 P, 1A-h10m 12B70bm 1.270 0.122 w - 35.56 3.42 69.02 1.07 0 0 0 0 0 0 0 0 30. 0 0. 1067 2071 C 16A-30md 0.032 0.90 2.32 369 369 331 857 259 259 232 600 F . ; 22A-4ph: 1.358 - 38 02 0'00 369 369 14031 0 259 259; 9848. Q 6 c) AED excursion -87 -3 Envelope loss/gain 19060 4078 16310 6292 12 a) Infiltration b) Room ventilation 494 0 139 0 692 0 195 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 Less external load 0 0 0 0 0 0 0 0 Less transfer Redistribution 0 0 0 0 0 0 0 0 14 15 Subtotal Duct loads 8% 35% 19554 1577 4217 1495 8% 35% 17002 1371 6487 2299 Total room load Air required (cfm) 21131 344 5712 264 18373 299 8787 406 _ Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoft Right -Suite Residential 6.0.27 RSR30402 2007-Aug-27 11:55:29 .4CC�k C:\My Documents\Wrightsoft HVAC\phillipsl.rrp Calc = MJ8 Orientation = N Page 2 Right-J Worksheet Job: Entire House Date: May 04, 2007 By: 1 Room name breakfast kitchen 2 Exposed wall 90.0 It 217.0 ft 3 Ceiling height 10.0 ft heat/cool 11.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 10.4 ft 93.6 ft2 15.1 x 14.4 ft 217.4 ft2 Ty ConsUuction number U-value (Btuh/ft2-°F) Or HTM (131uh/ft2) Area (W) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A-4ocs 0.143 n 4.00 2.55 - 64 256 163. 0 , 0 0 0' 1A-hlom 1A h1om 10A-m 1.270 1.270 1670 ❑ n . n 35.56 35.56 . 46.76 27.58 29.95 25.31 .104 40 0 0 0 0 "_ .. 0 1422 •0 0 ' 1103 0 .: 0 0 0 0! 0 0 0 0 0 0 0' 0 0 IW 11 13A-4ocs 1A-h1om 10A-m 0.143 1.270 1.670 a a a 4.00 35.56 46.76 2.55 69.02 53.19 0 0 0 0 0 0 0 0 0 0 0 0 158 18 0 140 0 0 561 640 0 356 1242 0 Vtl 13A-4ocs 0.143 s 4.00 2.55 6 0 0 0 0 0 0 0 1A-hlom 1.270 s 35.56 32.10 0 0 0 0 0 0 0 0 IWI 10A-m IA-hlom 13A-4ocs 1.670 1.270 0.143 s s w 46.76 35.56, 4.00 26.85 32.1A 2.55 0 0 0 0 0 0 0 0 0 0 0 0 0 6 0 0 6' 0 0 0 0 0 0 0 - �--G P C 1A-h1om „ _ 12B-Obm 16A-30md 1.270 '0.122 0.032 w - 35.56 3.42 0.90 69.02 1.07 2.32 0 0 94 0 0 94 0 0'. 84 _ _ _ 0 0 217 0 0 217 0. i 0 217 0 `6 195 ., 0 0 504 F` 22A-tph 1.358 3802 000 :.. 94 90 3422 0 217:. 217 8251; 0 6 c) AED excursion -31 25 Envelope loss/gain 5185 1 1452 1 1 96471 2128 12 a) Infiltration b) Room ventilation 203 0 57 0 309 0 87 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 1 1200 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 5388 1509 9955 3415 15 Duct loads 8% 35% 434 535 8% 35% 803 1210 Total room load 5822 2044 10758 4626 Air required (cfm) 95 94 175 214 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrlgHtsofC Right -Suite Residential6.0.27 RSR30402 2007-Aug-27 11:55:29 �� C:\My Documents\Wrightsoft HVAC\phillipsl.rrp Calc = MJ8 Orientation = N Page 3 •172,1111i1116.1gia Right-J Worksheet Job: Entire House Date: May 04, 2007 By: 1 Room name laund-stair-hall dining 2 Exposed wall 137.0 ft 155.0 ft 3 Ceiling height 10.0 ft heat/cool 11.0 ft heat/cool 4 Room dimensions 10.1 x 13.6 ft 13.7 x 11.6 ft 5 Room area 137.4 ft' 158.9 ftz Ty Construction U-value Or HTM Area (ft) Load Area (W) Load number (Btuhff °F) (13tuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A4ocs 0 143 •' n 4.00 2 55 0 0 0 0 0 0 .; 0 0 1A-hlom1270 n, 35.56 0 0 0 0 0 0 0 1A-h1om 1270 ri, 35.56 29:95 0 0 0 0 0 0 0: 0' 10A m° 1.670 n; 46.,7.E ... 25.3:1 0 0 0 0 0 0 0 0 11 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 l-G 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 �-( 10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0 IW . 13A flocs 0143 .s: 4.00 2.55 0 0 0 0 128 72 :, 288; 183 -, 1A hll= 1 270 s' 35.56 32.10 0 0 0 0 0 0 0 0'. 10A-m 1670 s• 46.76 M85 0 0 0 0 24 -_ 24 1122 606 1A h1om 1.276 s 35.56 32:10 "0 0 0 .= •.. 0 .. 32 32 1138968 IW 13A-4ocs 0.143 w 4.00 2.55 136 136 545 346 119 109 436 277 ' c 1A-h1om 1.270 w 35.56 69.02 . 0 _ 0 0 ,_ _,. 0 10 0 356 690 P 1<B-:Obm �:.� �,. 0.122 _ °. - <<3.42 .:= 1.08 , ;;;0 - . � 0 ... ,� :.. 0 0 `. 0- 0 ' p A C 16A-30md 0.032 0.90 2.32 137 137 123 319 159 159 142 369 224-tph�: = 1.358 -'' 38:02 0.00 -137 _n7 � -6266 " 0 , a "156 -_ , 155 894 " ,0 6 c) AED excursion -39 -65 Envelope loss/gain 15877 626193771 3020 12 a) Infiltration 266 75 483 136 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 1 1200 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6143 1900 9859 3156 15 Duct loads 8% 35% 495 674 8% 35% 795 1119 Total room load 6638 2574 1 1 10654 4275 Air required (cfm) 108 119 173 197 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoft Right -Suite Residential 6.0.27 RSR30402 2007-Aug-27 11:56:29 �� C:\My Documents\Wrightsoft HVACSphillipsl.rrp Calc = MJ8 Orientation = N Page 4 Right-J Worksheet Job: Entire House Date: May 04, 2007 By: 1 Room name powder bdrm 2 Exposed wall 35.0 ft 164.0 ft 3 Ceiling height 10.0 ft heattcool 10.0 ft heat/cool 4 Room dimensions 6.0 x 5.8 ft 15.0 x 12.6 ft 5 Room area 34.8 ft' 189.0 ft, Ty Construction U-value Or HTM Area (W) Load Area (ft� Load number (Btuh/ftz °F) (Bt or perimeter (ft) (13 h) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A4ocs 0.143 n 4 001. 2.55 0 0 0 0 0 0 0 0 1A-hlom 1.270 r 35,56 27.58 0 0 0 0 0 0' 0 0'. 1A-h1om 1.270 r 35.56 29.95 0 0 0 0 0 0 0 0' 10A-m - 1.670. -n 46.76 25.31 0 0 _ .0 .... 0 .0 0 0 0 W. F--cJ 11 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 126 126 505 321 1A-hlom 1.270 a 35.56 69.02 0 0 0 0 0 0 0 0 G 10A-m 1.670 a 46.76 53.19 0 0 0 0 0 0 0 0 13A-46cs 0.143 S 4.00 2.55 0 0 10 0 130 110 -440 286 1A hlom 1.270 s M.56 32.10 0 0 0 0 . 20' 20 711 599 10A-m. 1.670 s 46.76 26.85 0 0 0 0 0 0 0 0 1A,h16m 1.270 s 35.56 32.10 0 0 0_ 0. 0 0 0 0 IW 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 80 80 320 204 L-c 1A-hlom 1.270 w ,. 35,56 69.02 0 0 0 0 0 0 0 0.. . 1213-0bm: 0.122 _ 3'.42 1.07 0 .. 0, _0 :.0 0 0. 0 _0 0 C 16A-30md 0.032 0.90 2.32 35 35 31 81 189 189 169 438 F= ... 22A=tph,.; 1.358'' - . 38,02 0;00 ,. ::: 35 35 ' 1331 0 159, 164 6236' o: 6 c) AED excursion -2 -50 Envelope loss/gain 1362 79 8382 1791 12 a) Infiltration 0 0 656 185 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1362 79 9038 2437 15 Duct loads 8% 35% 110 28 8% 35% 729 864 Total room load 1472 107 1 9767 3300 Air required (cfm) 24 5 159 152 _ Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrIghtsoft Right -Suite Residential6.0.27 RSR30402 2007-Aug-27 11:55:29 �� C:\My Documents%Wrightsoft HVAC\phillipsl.rrp Calc = MJ8 Orientation = N Page 5 • Right-J Worksheet Job: May 04, Zoo7 Entire House By: 1 Room name bath 2 Exposed wall 48.0 ft 3 Ceiling height 10.0 ft heaticool 4 5 Room dimensions Room area 8.6 x 5.6 ft 48.2 ft' Ty Construction U-value Or HTM Area (ft� Load Area Load number (Btuh/ft2 °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W I1-- 13A-4ocs 0143 n 4.00 2.55 0 0 0 0 I--c ��� GGG 1A-h1om !A-h1om 1270 1270 `n n 35.56 35.56 27.58 29.95 0 01 0 0 0 6 0 (Y 10A-m 1.670 . n 46.76 25.31 0 0. _0 .. 0 V�j13A-4ocs 11 1A-hlom 0.143 1.270 a a 4.00 35.56 2.55 69.02 56 6 50 0 200 213 127 414 10A-m 1.670 a 46.76 53.19 0 0 0 0 W 13A-4ocs IA-h1om 0.143 1.270 s s 4.00 35.56 2.55 32.10 0 0 0 0 0 0 0 0 W 10A-m 1A-hlom 13A-4ocs 1.670 1.270 0.143 s" . s w 46.76 35.56 4.00 26.85 32.10 2.55 0 0 0 0 0 0 0 0. 0 0 0 0 L-G P 1A-hlom 126-0bm 1.2.70 0.122 w . - 35.56 3:42 69.02 1.07 0 0 0 0: 0 0 0 0 C 16A-30md 0.032 0.90 2.32 48 48 43 112 22A4ph 1.358 ',. 38 02 0.00 . 48 48 1825 0 6 c) AED excursion 17 Envelope loss/gain 2282 671 12 a) Infiltration 109 31 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances @ 1200 0 0 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2391 701 15 Duct loads 8% 35% 193 249 Total room load 2584 950 Air required (cfm) 42 44 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr�g htsoft Right -Suite Residential 6.0.27 RSR30402 2007-Aug-27 11:55:29 -4C(>, C:WIy Documents\Wrightsoft HVAC\phillipsl.rrp Calc = MJ8 Orientation = N Page 6