Loading...
HomeMy WebLinkAboutAPPROVED PlansLOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JKDESIGNER RESIDENCE NOTE: TOP OF POOL ELEVATION IS 6" LOWER THAN F.F.E. OF HOUSE A Custom Pool Designed Especially For: SCALE: 1/8" = 1' PAGE 1 DRAFTED BY: G.S.M. NOTE: POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO CONSTRUCTION N7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818 -3825 / wayne@wmb-pe.com SPECIFICATIONS POOL FINISH ITEMS WATER FEATURES DECK JETS: BUBBLERS: AUTO FILL: THERAPY JETS: SHEER DESCENT: LYONS HEADS: WATERFALL/ ROCK: OTHER: POOL DEPTH: VOLUME: (GALLONS) TURNOVER RATE: POOL SIZE: POOL PERIMETER: SPECIAL NOTES 6" RAISED BEAM: 12" RAISED BEAM: 18" RAISED BEAM: 24" RAISED BEAM: 36" RAISED BEAM: RAISED BEAM FINISH BEAM FINISH SIDES BEAM FINISH REAR ALARMS: ELECTRIC: GATES: POOL ENCLOSURE: OVERFLOW LINE: INTERIOR FINISH: DECK S.F.: DECK TYPE: CAPPING S.F. : FOOTERS: COPING: TILE: SWIMOUT: CAP TILE HANDHOLDS: POOL & AUXILLIARY POOL EQUIPMENT POOL PUMP: POOL FILTER: POOL INLETS: POOL LIGHT: POOL HEATER TYPE: POOL HEATER SIZE: CLEANING LINE: CLEANING SYSTEM: CHLORINATOR: SPA POOL S.F./ L.F. /GAL SPA JETS: SPA LIGHT: RAISED SPA: SPA COPING: SPA EXTERIOR: SPA SPILLWAY SIZE: AUTOMATED SYSTEM: BLOWER: BOOSTER PUMP: POOL AREA SQ. FT. BABY FENCE: DOD: HANDRAIL: PILING POOL: UMBRELLA SLEEVE: ACTUATORS: SKIMMER: SPA SIZE: SPECIFICATIONS POOL FINISH ITEMS WATER FEATURES DECK JETS: BUBBLERS: AUTO FILL: THERAPY JETS: SHEER DESCENT: LYONS HEADS: WATERFALL/ ROCK: OTHER: POOL DEPTH: VOLUME: (GALLONS) TURNOVER RATE: POOL SIZE: POOL PERIMETER: SPECIAL NOTES 6" RAISED BEAM: 12" RAISED BEAM: 18" RAISED BEAM: 24" RAISED BEAM: 36" RAISED BEAM: RAISED BEAM FINISH BEAM FINISH SIDES BEAM FINISH REAR ALARMS: ELECTRIC: GATES: POOL ENCLOSURE: OVERFLOW LINE: INTERIOR FINISH: DECK S.F.: DECK TYPE: CAPPING S.F. : FOOTERS: COPING: TILE: SWIMOUT: CAP TILE HANDHOLDS: POOL & AUXILLIARY POOL EQUIPMENT POOL PUMP: POOL FILTER: POOL INLETS: POOL LIGHT: POOL HEATER TYPE: POOL HEATER SIZE: CLEANING LINE: CLEANING SYSTEM: CHLORINATOR: SPA POOL S.F./ L.F. /GAL SPA JETS: SPA LIGHT: RAISED SPA: SPA COPING: SPA EXTERIOR: SPA SPILLWAY SIZE: AUTOMATED SYSTEM: BLOWER: BOOSTER PUMP: POOL AREA SQ. FT. BABY FENCE: DOD: HANDRAIL: PILING POOL: UMBRELLA SLEEVE: ACTUATORS: SKIMMER: SPA SIZE: SPECIFICATIONS POOL FINISH ITEMS WATER FEATURES DECK JETS: BUBBLERS: AUTO FILL: THERAPY JETS: SHEER DESCENT: LYONS HEADS: WATERFALL/ ROCK: OTHER: POOL DEPTH: VOLUME: (GALLONS) TURNOVER RATE: POOL SIZE: POOL PERIMETER: SPECIAL NOTES 6" RAISED BEAM: 12" RAISED BEAM: 18" RAISED BEAM: 24" RAISED BEAM: 36" RAISED BEAM: RAISED BEAM FINISH BEAM FINISH SIDES BEAM FINISH REAR ALARMS: ELECTRIC: GATES: POOL ENCLOSURE: OVERFLOW LINE: INTERIOR FINISH: DECK S.F.: DECK TYPE: CAPPING S.F. : FOOTERS: COPING: TILE: SWIMOUT: CAP TILE HANDHOLDS: POOL & AUXILLIARY POOL EQUIPMENT POOL PUMP: POOL FILTER: POOL INLETS: POOL LIGHT: POOL HEATER TYPE: POOL HEATER SIZE: CLEANING LINE: CLEANING SYSTEM: CHLORINATOR: SPA POOL S.F./ L.F. /GAL SPA JETS: SPA LIGHT: RAISED SPA: SPA COPING: SPA EXTERIOR: SPA SPILLWAY SIZE: AUTOMATED SYSTEM: BLOWER: BOOSTER PUMP: POOL AREA SQ. FT. BABY FENCE: DOD: HANDRAIL: PILING POOL: UMBRELLA SLEEVE: ACTUATORS: SKIMMER: SPA SIZE: SPECIFICATIONS POOL FINISH ITEMS WATER FEATURES DECK JETS: BUBBLERS: AUTO FILL: THERAPY JETS: SHEER DESCENT: LYONS HEADS: WATERFALL/ ROCK: OTHER: POOL DEPTH: VOLUME: (GALLONS) TURNOVER RATE: POOL SIZE: POOL PERIMETER: SPECIAL NOTES 6" RAISED BEAM: 12" RAISED BEAM: 18" RAISED BEAM: 24" RAISED BEAM: 36" RAISED BEAM: RAISED BEAM FINISH BEAM FINISH SIDES BEAM FINISH REAR ALARMS: ELECTRIC: GATES: POOL ENCLOSURE: OVERFLOW LINE: INTERIOR FINISH: DECK S.F.: DECK TYPE: CAPPING S.F. : FOOTERS: COPING: TILE: SWIMOUT: CAP TILE HANDHOLDS: POOL & AUXILLIARY POOL EQUIPMENT POOL PUMP: POOL FILTER: POOL INLETS: POOL LIGHT: POOL HEATER TYPE: POOL HEATER SIZE: CLEANING LINE: CLEANING SYSTEM: CHLORINATOR: SPA POOL S.F./ L.F. /GAL SPA JETS: SPA LIGHT: RAISED SPA: SPA COPING: SPA EXTERIOR: SPA SPILLWAY SIZE: AUTOMATED SYSTEM: BLOWER: BOOSTER PUMP: POOL AREA SQ. FT. BABY FENCE: DOD: HANDRAIL: PILING POOL: UMBRELLA SLEEVE: ACTUATORS: SKIMMER: SPA SIZE: DESIGNER RESIDENCE NOTE: TOP OF POOL ELEVATION IS 6" LOWER THAN F.F.E. OF HOUSE A Custom Pool Designed Especially For: SCALE: 1/8" = 1' PAGE 1 DRAFTED BY: G.S.M. NOTE: POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO CONSTRUCTION N7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818 -3825 / wayne@wmb-pe.com SPECIFICATIONS POOL FINISH ITEMS WATER FEATURES DECK JETS: BUBBLERS: AUTO FILL: THERAPY JETS: SHEER DESCENT: LYONS HEADS: WATERFALL/ ROCK: OTHER: POOL DEPTH: VOLUME: (GALLONS) TURNOVER RATE: POOL SIZE: POOL PERIMETER: SPECIAL NOTES 6" RAISED BEAM: 12" RAISED BEAM: 18" RAISED BEAM: 24" RAISED BEAM: 36" RAISED BEAM: RAISED BEAM FINISH BEAM FINISH SIDES BEAM FINISH REAR ALARMS: ELECTRIC: GATES: POOL ENCLOSURE: OVERFLOW LINE: INTERIOR FINISH: DECK S.F.: DECK TYPE: CAPPING S.F. : FOOTERS: COPING: TILE: SWIMOUT: CAP TILE HANDHOLDS: POOL & AUXILLIARY POOL EQUIPMENT POOL PUMP: POOL FILTER: POOL INLETS: POOL LIGHT: POOL HEATER TYPE: POOL HEATER SIZE: CLEANING LINE: CLEANING SYSTEM: CHLORINATOR: SPA POOL S.F./ L.F. /GAL SPA JETS: SPA LIGHT: RAISED SPA: SPA COPING: SPA EXTERIOR: SPA SPILLWAY SIZE: AUTOMATED SYSTEM: BLOWER: BOOSTER PUMP: POOL AREA SQ. FT. BABY FENCE: DOD: HANDRAIL: PILING POOL: UMBRELLA SLEEVE: ACTUATORS: SKIMMER: SPA SIZE: HRS JANDY FLO PRO 2.7 HP VSP SF CARTRIDGE 3 8' DIAMETER VAC SALT CHLORINATOR – LED NICHELESS HEAT PUMP GULFSTREAM 1 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 5' WOOD EXISTING FENCE TRAVERTINE 6 X 12 6" X 6" 425 N/A N/A 51' BY PPB N/A N/A YES YES DECK MOUNTED 2 QUARTZ 997 AS NEEDED PER CODE N/A 1 – IN SUN SHELF N/A 18"X8'6"S/O & 18"X12'BENCH ROBOT MX-6 136K HI-150 50SF/25LF 530 GAL +12" TILE TILE 6 1 LED NICHELESS IQ-904 1.5 HP N/A 25' CHAMPAGNE TRAVERTINE FRENCH 3' - 6' 13,690 5.924' X 35' 104'540 250 1- IN SUN SHELF N/A N/A 2 31'6"32'9"POOL EQUIPMENT SHALL BE SCREENED IF REQUIRED BY LOCAL CODE POOL EQUIP POOL EQUIP POOL EQUIPMENT SHALL BE SCREENED IF REQUIRED BY LOCAL CODE POOL EQUIP GFI LOCATION MIN 6' & MAX OF 20' TO WATERS EDGE GFI LOCATION MIN 6' & MAX OF 20' TO WATERS EDGE TOP EXISTING LANAI W/ TRAVERTINE 5' OF EXISTING WOOD PERIMETER FENCE VACVACVAC CLEANING LINE WITH VAC’LOC FITTING SHALL BE LOCATED NO GREATER THAN 12" BELOW WATER LEVEL APSP 7 SEC 4.6 VAC CLEANING LINE WITH VAC’LOC FITTING SHALL BE LOCATED NO GREATER THAN 12" BELOW WATER LEVEL APSP 7 SEC 4.6 SEE PIPING SCHEMATIC FOR DETAILS AND SIZES PAGE P-1 SEE PIPING SCHEMATIC FOR DETAILS AND SIZES PAGE P-1 15'5"DECK SHALL FINISH TO UPPER LANAI ELEVATION NO STEPS IN POOL DECK GRADE POOL FILL ON PROPERTY 18" x 8'6" SWIMOUT18" x 8'6" SWIMOUT +12" RAISED SPA W/ 6 JETS, 1 LED COLOR LIGHT, EXTERIOR TILED W/ 25' TILED CHAMPAGNE SPILLWAY +12" RAISED SPA W/ 6 JETS, 1 LED COLOR LIGHT, EXTERIOR TILED W/ 25' TILED CHAMPAGNE SPILLWAY #8 BARE COPPER WIRE FOR 360 DEGREE WITH 4 JUMPERS TO BE 18" -24" FROM WATERS EDGE #8 BARE COPPER WIRE FOR 360 DEGREE WITH 4 JUMPERS TO BE 18" -24" FROM WATERS EDGE 74' SF SUNSHELF W/ (1) EA BUBBLER & UMBRELLA HOLDER 74' SF SUNSHELF W/ (1) EA BUBBLER & UMBRELLA HOLDER UMBRELLA HOLDER UMBRELLA HOLDER5' 3'4" 3'8" 3' 6'RRRRRRRRROVERFLOW LINE OVERFLOW LINE DECO DRAINDECO DRAIN DECK MOUNTED IN POOL ALARM PER FBC 7TH EDICTION (2020) R4501.17.1.9(3) DECK MOUNTED IN POOL ALARM PER FBC 7TH EDICTION (2020) R4501.17.1.9(3) HANDHOLDS 11'BUBBLERBUBBLER +12" RAISED SPA W/ 6 JETS, 1 LED COLOR LIGHT, EXTERIOR TILED W/ 25' TILED CHAMPAGNE SPILLWAY #8 BARE COPPER WIRE FOR 360 DEGREE WITH 4 JUMPERS TO BE 18" -24" FROM WATERS EDGE 74' SF SUNSHELF W/ (1) EA BUBBLER & UMBRELLA HOLDER UMBRELLA HOLDER5' 3'4" 3'8" 3' 6'RRROVERFLOW LINE DECO DRAIN DECK MOUNTED IN POOL ALARM PER FBC 7TH EDICTION (2020) R4501.17.1.9(3) HANDHOLDS 11'BUBBLER 9'7" REVISION 7/1/2021 S-1 IMPORTANT NOTE: NO DIVING BOARD AND NO DIVING IS ALLOWED ON ANY POOL LESS THAN 8'0" DEEP AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL IS NOT DESIGNED FOR DIVING. 35'3'LONGITUDINAL POOL SECTION N.T.S. 10'20' 1:7 MAXIMUM SLOPE MAIN DRAIN WATER LINE 5'IMPORTANT NOTE: NO DIVING BOARD AND NO DIVING IS ALLOWED ON ANY POOL LESS THAN 8'0" DEEP AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL IS NOT DESIGNED FOR DIVING. 35'3'LONGITUDINAL POOL SECTION N.T.S. 10'20' 1:7 MAXIMUM SLOPE MAIN DRAIN WATER LINE 5' DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For:A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818 -3825 / wayne@wmb-pe.com DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818 -3825 / wayne@wmb-pe.com DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818 -3825 / wayne@wmb-pe.com 3"5"PER PLAN N.T.S. EARTH EARTHEARTH WATER LEVEL COPING STEP DETAIL 12" MIN 12" MIN 12" MAX12" MAX12" MAX12" MAXSTEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER 6 X 6 BEAM 2 #3 CONTINUOUS 3"5"PER PLAN N.T.S. EARTH EARTH WATER LEVEL COPING STEP DETAIL 12" MIN 12" MIN 12" MAX12" MAX12" MAX12" MAXSTEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER 6 X 6 BEAM 2 #3 CONTINUOUS 6" X 6" BEAM 2 #3 CONTINUOUS3"(TYP) TILE 18" N.T.S. BENCH DETAIL3"(TYP) TILE 18" N.T.S. BENCH DETAIL18"6" X 6" BEAM 2 #3 CONTINUOUS3"(TYP) TILE 18" N.T.S. BENCH DETAIL18"SWIMOUT DETAILN.T.S. (TYP.)18"18"3"TILE 6" X 6" BEAM 2 #3 CONTINUOUS SWIMOUT DETAILN.T.S. (TYP.)18"18"3"TILE 6" X 6" BEAM 2 #3 CONTINUOUS LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK 6" 6" N.T.S. LOCATE AT WATERLINE 6" 6" N.T.S. LOCATE AT WATERLINE WATER LEVEL COPING N.T.S. DECK 9" MAX CERAMIC TILE HANDHOLD MAXIMUM SPACING SHALL NOT EXCEED 48" CERAMIC HANDHOLD DETAIL 6" 6" N.T.S. LOCATE AT WATERLINE WATER LEVEL COPING N.T.S. DECK 9" MAX CERAMIC TILE HANDHOLD MAXIMUM SPACING SHALL NOT EXCEED 48" CERAMIC HANDHOLD DETAIL MAIN DRAIN--SEE DETAIL TILE & WATER LEVEL EARTH AUX BEAM & COPING EXTERIOR SPA FINISH TO BE DETERMINED 3'18" HIGH BENCH W/ TILED EDGE IF REQUIRED SPILLWAY OR WALL 5" BELOW BEAM SEE TYPICAL WALL SECTION FOR DETAILS AQUASTAR 32" CDFL - 32" CHANNEL DRAIN (316) GPM @ 3.9 FT / SEC THRU GRATE SINGLE UNBLOCKABLE OR EQUAL HYDROSTATIC RELIEF VALVE 3" SUCTION TO PUMP +12"SPA DETAIL 18"STEP N.T.S. BEND STEEL TO GO UNDERNEATH CHANNEL DRAIN MUST MAINTAIN 2" CLEARANCE ALL SIDES 2 # 3 CONTINIOUS MAIN DRAIN--SEE DETAIL TILE & WATER LEVEL EARTH AUX BEAM & COPING EXTERIOR SPA FINISH TO BE DETERMINED 3'18" HIGH BENCH W/ TILED EDGE IF REQUIRED SPILLWAY OR WALL 5" BELOW BEAM SEE TYPICAL WALL SECTION FOR DETAILS AQUASTAR 32" CDFL - 32" CHANNEL DRAIN (316) GPM @ 3.9 FT / SEC THRU GRATE SINGLE UNBLOCKABLE OR EQUAL HYDROSTATIC RELIEF VALVE 3" SUCTION TO PUMP +12"SPA DETAIL 18"STEP N.T.S. BEND STEEL TO GO UNDERNEATH CHANNEL DRAIN MUST MAINTAIN 2" CLEARANCE ALL SIDES 2 # 3 CONTINIOUS 10" BEAM DOUBLE MAT OF #3's @ 9" O.C. EACH WAY 8" FLOOR: #3's @ 9" O.C. EACH WAY (2) #3'S CONT IN ALL BOND BEAMS 10"10"SEE PLAN MAIN DRAIN--SEE DETAIL TILE & WATER LEVEL EARTH AUX BEAM & COPING EXTERIOR SPA FINISH TO BE DETERMINED 3'18" HIGH BENCH W/ TILED EDGE IF REQUIRED SPILLWAY OR WALL 5" BELOW BEAM SEE TYPICAL WALL SECTION FOR DETAILS AQUASTAR 32" CDFL - 32" CHANNEL DRAIN (316) GPM @ 3.9 FT / SEC THRU GRATE SINGLE UNBLOCKABLE OR EQUAL HYDROSTATIC RELIEF VALVE 3" SUCTION TO PUMP +12"SPA DETAIL 18"STEP N.T.S. BEND STEEL TO GO UNDERNEATH CHANNEL DRAIN MUST MAINTAIN 2" CLEARANCE ALL SIDES 2 # 3 CONTINIOUS 10" BEAM DOUBLE MAT OF #3's @ 9" O.C. EACH WAY 8" FLOOR: #3's @ 9" O.C. EACH WAY (2) #3'S CONT IN ALL BOND BEAMS 10"10"SEE PLAN 6" X 6" BEAM W/2- #3 CONT. WATER LINE 6" MIN 6" MIN.BULLNOSE OR CONCRETE CANTILEVER CAP POURED IN PLACE. TILE APPROVED FINISH 3" TYPICAL WALL SECTION N.T.S. STEELTEX FORM , KRAFTBOARD OR EQUIV. 6" MIN. GUNITE/SHOTCRETE WALLS & FLOOR WITH #3 BARS @ 9" O.C.E.W.CENTERED INTERLOCKING TRAVERTINE / PAVER SET IN SAND ON COMPACTED FILL SLOPE ¼” 6" X 6" BEAM W/2- #3 CONT. WATER LINE 6" MIN 6" MIN.BULLNOSE OR CONCRETE CANTILEVER CAP POURED IN PLACE. TILE APPROVED FINISH 3" TYPICAL WALL SECTION N.T.S. STEELTEX FORM , KRAFTBOARD OR EQUIV. 6" MIN. GUNITE/SHOTCRETE WALLS & FLOOR WITH #3 BARS @ 9" O.C.E.W.CENTERED INTERLOCKING TRAVERTINE / PAVER SET IN SAND ON COMPACTED FILL SLOPE ¼” 6" X 6" BEAM W/2- #3 CONT. WATER LINE 6" MIN 6" MIN.BULLNOSE OR CONCRETE CANTILEVER CAP POURED IN PLACE. TILE APPROVED FINISH 3" TYPICAL WALL SECTION N.T.S. STEELTEX FORM , KRAFTBOARD OR EQUIV. 6" MIN. GUNITE/SHOTCRETE WALLS & FLOOR WITH #3 BARS @ 9" O.C.E.W.CENTERED INTERLOCKING TRAVERTINE / PAVER SET IN SAND ON COMPACTED FILL SLOPE ¼” POOL LIGHT U.L. APPROVED POOL STEEL LOW VOTLAGE NICHELESS LIGHT 1 ½”" PVC CONDUIT LIGHT NICHE DETAIL FROM 12V TRANSFORMER N.T.S. 4" MIN. FROM WATER LEVEL TO TOP OF LENS POOL LIGHT U.L. APPROVED POOL STEEL LOW VOTLAGE NICHELESS LIGHT 1 ½”" PVC CONDUIT LIGHT NICHE DETAIL FROM 12V TRANSFORMER N.T.S. 4" MIN. FROM WATER LEVEL TO TOP OF LENS NOTE: BOND WIRE TO BE SECURED TO STEEL WITH APPROVED CLAMP. TO BE ENCASED IN DECK SLAB OR CONCRETE BOX PROVIDING MIN. 3" OF COVER AROUND CLAMP POOL BOND SCHEMATIC N.T.S. POOL BOND SCHEMATIC N.T.S. TO POOL EQUIPMENT #8 BARE COPPER WIRE FOR 360° WITH 4 JUMPERS TO BE 18" TO 24" FROM WATERS EDGEWATER LINE 3" N.T.S. PER FLORIDA BUILDING CODE ADAPTION OF N.E.C. 2017 SEC 680.26 EQUIPOTENTIAL BONDING GRID DETAIL #8 BARE COPPER WIRE FOR 360° WITH 4 JUMPERS TO BE 18" TO 24" FROM WATERS EDGEWATER LINE 3" N.T.S. PER FLORIDA BUILDING CODE ADAPTION OF N.E.C. 2017 SEC 680.26 EQUIPOTENTIAL BONDING GRID DETAIL NOTE: PROVIDE CONTINOUS SINGLE #8 COOPER BONDED IN FOUR POINTS (360 ) AROUND POOL & SPA AS PER N.E.C. 2017 ART. 680.26 (B) & (C) o NOTE: PROVIDE CONTINOUS SINGLE #8 COOPER BONDED IN FOUR POINTS (360 ) AROUND POOL & SPA AS PER N.E.C. 2017 ART. 680.26 (B) & (C) o NOTE: BOND WIRE TO BE SECURED TO STEEL WITH APPROVED CLAMP. TO BE ENCASED IN DECK SLAB OR CONCRETE BOX PROVIDING MIN. 3" OF COVER AROUND CLAMP POOL BOND SCHEMATIC N.T.S. TO POOL EQUIPMENT #8 BARE COPPER WIRE FOR 360° WITH 4 JUMPERS TO BE 18" TO 24" FROM WATERS EDGEWATER LINE 3" N.T.S. PER FLORIDA BUILDING CODE ADAPTION OF N.E.C. 2017 SEC 680.26 EQUIPOTENTIAL BONDING GRID DETAIL NOTE: PROVIDE CONTINOUS SINGLE #8 COOPER BONDED IN FOUR POINTS (360 ) AROUND POOL & SPA AS PER N.E.C. 2017 ART. 680.26 (B) & (C) o E-1E-1 DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For:A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818-3825 / wayne@wmb-pe.com ELECTRICAL CODE and NOTES: National Electrical Code (NEC), NFPA 70 - 2017 shall specifically govern, including Article 680 Swimming Pools, Fountains, and Similar Installations Article 430.32 Continuous-Duty Motors. Each motor used in continues duty application shall be protected against overload Article 680.6 Grounding. Electrical equipment shall be grounded in accordance with Parts V, VI and VII of Article 250 and connected by wiring methods of Chapter 3, except as modified by this Article. The following equipment shall be grounded: (1) Through-wall lighting assemblies and underwater luminaires, other than those low-voltage lighting products listed for the application without a grounding conductor (2) All electrical equipment located within 1.5 m (5 ft) of the inside wall of the specified body of water (3) All electrical equipment associated with the recirculating system of the specified body of water (4) Junction boxes (5) Transformer and power supply enclosures (6) Ground-fault circuit interrupters (7) Panelboards that are not part of the service equipment and that supply any electrical equipment associated with the body of water Article 680.9 Overhead Conductor Clearances. Overhead conductors shall meet the clearance requirements in this section. Where a minimum clearance from the water level is given, the measurement shall be taken from the maximum water level of the specified body of water. (A) Power. With respect to service -drop conductors, overhead service conductors, and open overhead wiring, swimming pool and similar installations shall comply with the minimum clearances given in Table 680.9(A) and illustrated in Figure 680.9(A). (B) Communications Systems. Communications, radio, and television coaxial cables within the scope of Articles 800 to 820 shall be permitted at a height of not less than 3.0 m (10 ft) above swimming and wading pools, diving structures, and observation stands, towers, or platforms. (C) Network -Powered Broadband Communications Systems. The minimum clearances for overhead network -powered broadband communications systems conductors from pools or fountains shall comply with the provisions in Table 680.9(A) for conductors operating at 0 to 750 volts to ground. Article 680.10 Electric Pool Water Heaters. All electric pool water heaters shall have the heating elements subdivided into loads not exceeding 48 amperes and protected at not over 60 amperes. The ampacity of the branch-circuit conductors and the rating or setting of overcurrent protective devices shall not be less than 125 percent of the total nameplate-rated load. Article 680.11 Underground Wiring Location. Underground wiring shall be permitted where installed in rigid metal conduit, intermediate metal conduit, rigid polyvinyl chloride conduit, reinforced thermosetting resin conduit, or Type MC cable, suitable for the conditions subject to that location. Underground wiring shall not be permitted under the pool unless this wiring is necessary to supply pool equipment permitted by this article. Minimum cover depths shall be as given in Table 300.5. Article 680.22 Lighting, Receptacles, and Equipment. (A) Receptacles. (1) Required Receptacle, Location. Where a permanently installed pool is installed, no fewer than one 125 - volt, 15- or 20-ampere receptacle on a general-purpose branch circuit shall be located not less than 1.83 m (6 ft) from, and not more than 6.0 m (20 ft) from, the inside wall of the pool. This receptacle shall be located not more than 2.0 m (6 ft 6 in.) above the floor, platform, or grade level serving the pool. (2) Circulation and Sanitation System, Location. Receptacles that provide power for water-pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. These receptacles shall have GFCI protection and be of the grounding type. (3) Other Receptacles, Location. Other receptacles shall be not less than 1.83 m (6 ft) from the inside walls of a pool. (4) GFCI Protection. All 15- and 20-ampere, single-phase, 125-volt receptacles located within 6.0 m (20 ft) of the inside walls of a pool shall be protected by a ground-fault circuit interrupter. E-1 DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818-3825 / wayne@wmb-pe.com ELECTRICAL CODE and NOTES: National Electrical Code (NEC), NFPA 70 - 2017 shall specifically govern, including Article 680 Swimming Pools, Fountains, and Similar Installations Article 430.32 Continuous-Duty Motors. Each motor used in continues duty application shall be protected against overload Article 680.6 Grounding. Electrical equipment shall be grounded in accordance with Parts V, VI and VII of Article 250 and connected by wiring methods of Chapter 3, except as modified by this Article. The following equipment shall be grounded: (1) Through-wall lighting assemblies and underwater luminaires, other than those low-voltage lighting products listed for the application without a grounding conductor (2) All electrical equipment located within 1.5 m (5 ft) of the inside wall of the specified body of water (3) All electrical equipment associated with the recirculating system of the specified body of water (4) Junction boxes (5) Transformer and power supply enclosures (6) Ground-fault circuit interrupters (7) Panelboards that are not part of the service equipment and that supply any electrical equipment associated with the body of water Article 680.9 Overhead Conductor Clearances. Overhead conductors shall meet the clearance requirements in this section. Where a minimum clearance from the water level is given, the measurement shall be taken from the maximum water level of the specified body of water. (A) Power. With respect to service -drop conductors, overhead service conductors, and open overhead wiring, swimming pool and similar installations shall comply with the minimum clearances given in Table 680.9(A) and illustrated in Figure 680.9(A). (B) Communications Systems. Communications, radio, and television coaxial cables within the scope of Articles 800 to 820 shall be permitted at a height of not less than 3.0 m (10 ft) above swimming and wading pools, diving structures, and observation stands, towers, or platforms. (C) Network -Powered Broadband Communications Systems. The minimum clearances for overhead network -powered broadband communications systems conductors from pools or fountains shall comply with the provisions in Table 680.9(A) for conductors operating at 0 to 750 volts to ground. Article 680.10 Electric Pool Water Heaters. All electric pool water heaters shall have the heating elements subdivided into loads not exceeding 48 amperes and protected at not over 60 amperes. The ampacity of the branch-circuit conductors and the rating or setting of overcurrent protective devices shall not be less than 125 percent of the total nameplate-rated load. Article 680.11 Underground Wiring Location. Underground wiring shall be permitted where installed in rigid metal conduit, intermediate metal conduit, rigid polyvinyl chloride conduit, reinforced thermosetting resin conduit, or Type MC cable, suitable for the conditions subject to that location. Underground wiring shall not be permitted under the pool unless this wiring is necessary to supply pool equipment permitted by this article. Minimum cover depths shall be as given in Table 300.5. Article 680.22 Lighting, Receptacles, and Equipment. (A) Receptacles. (1) Required Receptacle, Location. Where a permanently installed pool is installed, no fewer than one 125 - volt, 15- or 20-ampere receptacle on a general-purpose branch circuit shall be located not less than 1.83 m (6 ft) from, and not more than 6.0 m (20 ft) from, the inside wall of the pool. This receptacle shall be located not more than 2.0 m (6 ft 6 in.) above the floor, platform, or grade level serving the pool. (2) Circulation and Sanitation System, Location. Receptacles that provide power for water-pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. These receptacles shall have GFCI protection and be of the grounding type. (3) Other Receptacles, Location. Other receptacles shall be not less than 1.83 m (6 ft) from the inside walls of a pool. (4) GFCI Protection. All 15- and 20-ampere, single-phase, 125-volt receptacles located within 6.0 m (20 ft) of the inside walls of a pool shall be protected by a ground-fault circuit interrupter. LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK ¾” PVC CONDUIT W/ 2 #4 HOT, 1 #8 GRND. 1 #8 NEUTRAL 48" MIN. 1" NON-CORROSIVE CONDUIT 2 #12, 1 #12 GRND. (1) JUNCTION BOX ELECTRICAL RISER DIAGRAMBELOW WATERN.T.S. EXISTING METER F.P.L. POOL DECK LEVEL 8" MIN.4"-6" MIN.ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE EXISTING SERVICE AND PANEL HAS ENOUGH CAPACITY TO ACCOMMODATE THE ADDED POOL EQUIPMENT LOAD PER NEC 220.82" BLOWER MOTOR 2 #12 , 1 #12 GRND. ½” PVC SALT CHLORINATOR 2 #12, 1 #12 GRND. ½” PVC HEAT PUMP 2 #6, 1 #10 GRND. ¾” PVC POOL PUMP 3 #12, 1 #12 GRND. GFCI PROTECTED ½” PVC GFCI 6' TO 20' FROM WATER GFCI 6' TO 20' FROM WATER 1. IN POOL AREA GROUND ALL BOXES, RAILS, LIGHT, MOTOR ECT WITH #8 BARE COPPER WIRE 2. ALL ELECTRICLA TO COMPLY WITH 2017 NATIONAL ELECTRICAL CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION 3. #12 THHN CU ½” MIN. CONDUIT FOR POOL LIGHT(S). 4. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B). 5. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL – BY OTHERS 6. PROVIDE G.F.C.I. OUTLET 6' MIN - 20' MAX FROM WATER’S EDGE. NOTE: BASED ON INFORMATION PROVIDED TO THIS OFFICE, THE EXISTING SERVICE IS ADEQUATE FOR THE PROPOSED ADDITIONAL POOL EQUIPMENT LOAD EXISTING PANEL 2P 80A BREAKER FEEDING POOL POOL PANEL PUMP (1) – 2 P-20A GFCI LIGHT – BLOWER - CHLORINATOR (1) – 1P-15A HEATER (1) – 2P – 50A GFCI TRANSFORMER 120-12V 300 W/ TRANSF EXISTING PANEL 2P 80A BREAKER FEEDING POOL POOL PANEL PUMP (1) – 2 P-20A GFCI LIGHT – BLOWER - CHLORINATOR (1) – 1P-15A HEATER (1) – 2P – 50A GFCI TRANSFORMER 120-12V 300 W/ TRANSF (2) 24 W L.E.D. NICHELESS LIGHTS (POOL) (1) 6W L.E.D. NICHELESS LIGHTS (SPA) ¾” PVC CONDUIT W/ 2 #4 HOT, 1 #8 GRND. 1 #8 NEUTRAL 48" MIN. 1" NON-CORROSIVE CONDUIT 2 #12, 1 #12 GRND. (1) JUNCTION BOX ELECTRICAL RISER DIAGRAMBELOW WATERN.T.S. EXISTING METER F.P.L. POOL DECK LEVEL 8" MIN.4"-6" MIN.ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE EXISTING SERVICE AND PANEL HAS ENOUGH CAPACITY TO ACCOMMODATE THE ADDED POOL EQUIPMENT LOAD PER NEC 220.82" BLOWER MOTOR 2 #12 , 1 #12 GRND. ½” PVC SALT CHLORINATOR 2 #12, 1 #12 GRND. ½” PVC HEAT PUMP 2 #6, 1 #10 GRND. ¾” PVC POOL PUMP 3 #12, 1 #12 GRND. GFCI PROTECTED ½” PVC GFCI 6' TO 20' FROM WATER 1. IN POOL AREA GROUND ALL BOXES, RAILS, LIGHT, MOTOR ECT WITH #8 BARE COPPER WIRE 2. ALL ELECTRICLA TO COMPLY WITH 2017 NATIONAL ELECTRICAL CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION 3. #12 THHN CU ½” MIN. CONDUIT FOR POOL LIGHT(S). 4. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B). 5. LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL – BY OTHERS 6. PROVIDE G.F.C.I. OUTLET 6' MIN - 20' MAX FROM WATER’S EDGE. NOTE: BASED ON INFORMATION PROVIDED TO THIS OFFICE, THE EXISTING SERVICE IS ADEQUATE FOR THE PROPOSED ADDITIONAL POOL EQUIPMENT LOAD EXISTING PANEL 2P 80A BREAKER FEEDING POOL POOL PANEL PUMP (1) – 2 P-20A GFCI LIGHT – BLOWER - CHLORINATOR (1) – 1P-15A HEATER (1) – 2P – 50A GFCI TRANSFORMER 120-12V 300 W/ TRANSF (2) 24 W L.E.D. NICHELESS LIGHTS (POOL) (1) 6W L.E.D. NICHELESS LIGHTS (SPA) AUTOMATION SEE NOTES PAGE PUMP FRAME FILTER TANK MOUNT 1 3/4" X 3/16" TAP CON. FILTER POOL PUMP, FILTER ANCHOR POINTS (TYP.) POOL PUMP, FILTER ANCHOR POINTS (TYP.) FILTER POOL PUMP, FILTER ANCHOR POINTS (TYP.) FIBERMESH MAY BE USED IN LIEU OF WWF POOL EQUIPMENT ANCHORING & SLAB DETAIL N.T.S. PUMPPUMP SEE NOTES PAGE PUMP FRAME FILTER TANK MOUNT 1 3/4" X 3/16" TAP CON. FILTER POOL PUMP, FILTER ANCHOR POINTS (TYP.) FIBERMESH MAY BE USED IN LIEU OF WWF POOL EQUIPMENT ANCHORING & SLAB DETAIL N.T.S. PUMP SUCTION CLEANER LINE DETAIL VACUUM FITTING WITH SELF-CLOSING SAFETY COVER SUCTION CLEANER LINE DETAIL VACUUM FITTING WITH SELF-CLOSING SAFETY COVER 3.5"3"3"1'3"2'6"SKIMMER DETAIL N.T.S.3.5"3"3"1'3"2'6"SKIMMER DETAIL N.T.S. WATER LEVEL ADJUSTABLE WEIRDECK BASKET SUCTION LINE (TO FILTER EARTH 3.5"3"3"1'3"2'6"SKIMMER DETAIL N.T.S. WATER LEVEL ADJUSTABLE WEIRDECK BASKET SUCTION LINE (TO FILTER EARTH DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For:A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818 -3825 / wayne@wmb-pe.com DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818 -3825 / wayne@wmb-pe.com DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818 -3825 / wayne@wmb-pe.com P-1 ALL POOL & SPA SUCTION INLETS SHALL BE PROVIDED WITH A COVER THAT HAS BEEN TESTED & ACCEPTED BY A RECOGNIZED TESTING FACILITY & COMPLY WITH ANSI/ASME A 112.19.8M. " SUCTION FITTINGS FOR USE IN SWIMMING POOLS, SPAS, HOT TUBS & WHIRLPOOL BATHTUB APPLIANCES CHANNEL MAIN DRAIN DETAIL AQUASTAR 32" CDFL CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE- SINGLE UNBLOCKABLE OR EQUAL 1/2" ROCK BED CLOTH (RECOMMENDED) FLOORFINISH PLASTER MAIN DRAIN SUCTON LINE TIED TOGETHER AS SHOWN ABOVE – PIPE SIZE PER PLAN NOTE: 25.9 SQ IN OPEN AREA, 316 GPM = 3.9 FEET PER SECOND 32" 3 3/32" HYDROSTATIC RELIEF VALVE HYDROSTATIC RELIEF VALVE ALL POOL & SPA SUCTION INLETS SHALL BE PROVIDED WITH A COVER THAT HAS BEEN TESTED & ACCEPTED BY A RECOGNIZED TESTING FACILITY & COMPLY WITH ANSI/ASME A 112.19.8M. " SUCTION FITTINGS FOR USE IN SWIMMING POOLS, SPAS, HOT TUBS & WHIRLPOOL BATHTUB APPLIANCES CHANNEL MAIN DRAIN DETAIL AQUASTAR 32" CDFL CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE- SINGLE UNBLOCKABLE OR EQUAL 1/2" ROCK BED CLOTH (RECOMMENDED) FLOORFINISH PLASTER MAIN DRAIN SUCTON LINE TIED TOGETHER AS SHOWN ABOVE – PIPE SIZE PER PLAN NOTE: 25.9 SQ IN OPEN AREA, 316 GPM = 3.9 FEET PER SECOND 32" 3 3/32" HYDROSTATIC RELIEF VALVE LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK APSP/ANSI-7 POOL Y N AQUASTAR 32" CHANNEL 316 130 3 3 JANDY FLO PRO 2.7 HP VSFHP270 THIS DATA IS FOR THE: SINGLE UNBLOCKABLE? TWO OR MORE? (IF SINGLE UNBLOCKABLE INDICATE MAKE AND MODEL NUMBER) DRAIN MAKE AND MODEL#: LISTED COVER FLOW RATE: GPM SYSTEM FLOW RATE: GPM METHOD DETERMINING FLOW RATE: MAX FLOW FROM PUMP CURVE PUMP MAKE AND MODEL#: SUCTION PIPING: BRANCH PIPING SIZE INCH @ 6 FPS OR LOWER TRUNK PIPING SIZE INCH @ 8 FPS OR LOWER APSP/ANSI-7 POOL Y N AQUASTAR 32" CHANNEL 316 130 3 3 JANDY FLO PRO 2.7 HP VSFHP270 THIS DATA IS FOR THE: SINGLE UNBLOCKABLE? TWO OR MORE? (IF SINGLE UNBLOCKABLE INDICATE MAKE AND MODEL NUMBER) DRAIN MAKE AND MODEL#: LISTED COVER FLOW RATE: GPM SYSTEM FLOW RATE: GPM METHOD DETERMINING FLOW RATE: MAX FLOW FROM PUMP CURVE PUMP MAKE AND MODEL#: SUCTION PIPING: BRANCH PIPING SIZE INCH @ 6 FPS OR LOWER TRUNK PIPING SIZE INCH @ 8 FPS OR LOWER APSP/ANSI-15 FLOW CALCULATIONS PER STANDARD: POOL WATER VOLUME /360= GPM CALCULATED FLOW RATE. NOTE POOLS UNDER 13,000 GALLONS, THE CALCULATED FLOW RATE OR 36 GPM WHICHEVER IS GREATER = THE FILTRATION FLOW RATE IS THERE AND AUXILIARY LOAD ON THE FILTRATION PUMP? IF SO, WHAT IS THE CALCULATION AUXILIARY FLOW RATE: GPM MINIMUM FLOW RATE GPM (GREATER OF THE FILTRATION FLOW RATE OR THE AUX FLOW RATE IF THE AUX FLOW RATE IS POWERED BY THE FILTRATION PUMP) ALL LISTED BELOW PIPING IS FOR FILTRATION PUMP ONLY MINIMUM SUCTION PIPING SIZE @ 6 FPS MINIMUM SUCTION BRANCH PIPE @ 8 FPS MINIMUM RETURN PIPING SIZE @ 8 FPS MINIMUM RETURN BRANCH PIPE @ 8 FPS FILTER TYPE AND SIZE: MINIMUM FILTER AREA PER FILTER FACTOR IN STANDARD X = GPM (MAXIMUM FLOW THROUGH FILTER FACTOR: FILTER AREA X .375 (CART), X 2 (DE) OR X 1.5 (SAND) BACKWASH VALVE: (IF YES, MUST BE 2" MINIMUM) HEATER MAKE AND MODEL#: GAS HEATER EFFICIENCY RATING: (NO PILOT LIGHT) HEAT PUMP EFFICIENCY C.O.P.: PUMP SELECTION AS LISTED ON CURVE (A= < THAN 17,000 GAL OR C= > THAN 17,001 GAL) PUMP MAKE AND MODEL#: FLOW RATE GPM RPM (FLOW RATE MUST BE < OR = MAX FILTER FLOW RATE) PUMP CONTROLS= FILTRATION PUMP HAS NO AUX LOAD- STANDARD TIME CLOCK FILTRATION PUMP WITH AUXILIARY LOAD- CONTROL MODEL FOR LOW SPEED DEFAULT WITH 24HR YES 72 72 3 3 39 250 .375 94 13,690 CARTRIDGE 250 SF 136,000 GULFSTREAM HI150 YES N/A A 30 6.0 3 3 600 JANDY FLO PRO 2.7 HP VSFHP270 APSP/ANSI-15 FLOW CALCULATIONS PER STANDARD: POOL WATER VOLUME /360= GPM CALCULATED FLOW RATE. NOTE POOLS UNDER 13,000 GALLONS, THE CALCULATED FLOW RATE OR 36 GPM WHICHEVER IS GREATER = THE FILTRATION FLOW RATE IS THERE AND AUXILIARY LOAD ON THE FILTRATION PUMP? IF SO, WHAT IS THE CALCULATION AUXILIARY FLOW RATE: GPM MINIMUM FLOW RATE GPM (GREATER OF THE FILTRATION FLOW RATE OR THE AUX FLOW RATE IF THE AUX FLOW RATE IS POWERED BY THE FILTRATION PUMP) ALL LISTED BELOW PIPING IS FOR FILTRATION PUMP ONLY MINIMUM SUCTION PIPING SIZE @ 6 FPS MINIMUM SUCTION BRANCH PIPE @ 8 FPS MINIMUM RETURN PIPING SIZE @ 8 FPS MINIMUM RETURN BRANCH PIPE @ 8 FPS FILTER TYPE AND SIZE: MINIMUM FILTER AREA PER FILTER FACTOR IN STANDARD X = GPM (MAXIMUM FLOW THROUGH FILTER FACTOR: FILTER AREA X .375 (CART), X 2 (DE) OR X 1.5 (SAND) BACKWASH VALVE: (IF YES, MUST BE 2" MINIMUM) HEATER MAKE AND MODEL#: GAS HEATER EFFICIENCY RATING: (NO PILOT LIGHT) HEAT PUMP EFFICIENCY C.O.P.: PUMP SELECTION AS LISTED ON CURVE (A= < THAN 17,000 GAL OR C= > THAN 17,001 GAL) PUMP MAKE AND MODEL#: FLOW RATE GPM RPM (FLOW RATE MUST BE < OR = MAX FILTER FLOW RATE) PUMP CONTROLS= FILTRATION PUMP HAS NO AUX LOAD- STANDARD TIME CLOCK FILTRATION PUMP WITH AUXILIARY LOAD- CONTROL MODEL FOR LOW SPEED DEFAULT WITH 24HR YES 72 72 3 3 39 250 .375 94 13,690 CARTRIDGE 250 SF 136,000 GULFSTREAM HI150 YES N/A A 30 6.0 3 3 600 JANDY FLO PRO 2.7 HP VSFHP270 JANDY VSFHP270AUT 2.7 THP FLOPRO VARIABLE SPEED PUMP 130 GPM @ 35 TDH SELF -PRIMING W/ APPROVED HAIR AND LINT STRAINER JANDY CS250 250-SQUARE- FOOT SINGLE ELEMENT CARTRIDGE FILTER AUTOMATION GULFSTREAM HI150-R-A 136,000 BTU, 6.0 COP HEATER, 230V/60HZ, SINGLE PHASE, TITANIUM, 20-70 GPM DIGITAL, POOL/SPA HEAT PUMP CHECK VALVE AS NEEDED PUMP W/ HAIR & LINT STRAINER PRESSURE GAUGE & AIR RELIEF VALVE PIPING SCHEMATIC N.T.S. 2" POOL WASTE RETAIN ON SITE 3 WAY 3" POOL INLETS (8 FPS) 1.5"BUBBLER2.5" SPA JETS (8 FPS) 2" SKIMMER3-WAY VacVac2" CLEANER LINE(1) 32" CHANNEL POOL MAIN DRAIN AQUA STAR UNBLOCKABLE VGB COMPLIANT(1) 32" CHANNEL POOL MAIN DRAIN AQUA STAR UNBLOCKABLE VGB COMPLIANT3" MAIN DRAIN (6 FPS)(1) 32" CHANNEL SPA MAIN DRAIN AQUA STAR UNBLOCKABLE VGB COMPLIANT(1) 32" CHANNEL SPA MAIN DRAIN AQUA STAR UNBLOCKABLE VGB COMPLIANT3" MAIN DRAIN (6 FPS)TDH CALCS:PIPING & FITTINGS: 10 TDH FILTER: 10 TDH HEATER: 10 TDH CHLORINATOR: 5 TDH TOTAL: 35 TDH TDH CALCS:PIPING & FITTINGS: 10 TDH FILTER: 10 TDH HEATER: 10 TDH CHLORINATOR: 5 TDH TOTAL: 35 TDH TDH CALCS:PIPING & FITTINGS: 10 TDH FILTER: 10 TDH HEATER: 10 TDH CHLORINATOR: 5 TDH TOTAL: 35 TDH WATER BONDING FITTING PB -2008 1" UL LISTED 40YZ PERMA CAST COMPANY WATER BONDING FITTING PB -2008 1" UL LISTED 40YZ PERMA CAST COMPANY 3-WAY 3-WAY 3 WAY 3 WAY SALT CHLORINATOR SALT CHLORINATOR CHECK VALVE AS NEEDED PUMP W/ HAIR & LINT STRAINER PRESSURE GAUGE & AIR RELIEF VALVE PIPING SCHEMATIC N.T.S. 2" POOL WASTE RETAIN ON SITE 3 WAY 3" POOL INLETS (8 FPS) 1.5"BUBBLER2.5" SPA JETS (8 FPS) 2" SKIMMER3-WAY Vac2" CLEANER LINE(1) 32" CHANNEL POOL MAIN DRAIN AQUA STAR UNBLOCKABLE VGB COMPLIANT3" MAIN DRAIN (6 FPS)(1) 32" CHANNEL SPA MAIN DRAIN AQUA STAR UNBLOCKABLE VGB COMPLIANT3" MAIN DRAIN (6 FPS)TDH CALCS:PIPING & FITTINGS: 10 TDH FILTER: 10 TDH HEATER: 10 TDH CHLORINATOR: 5 TDH TOTAL: 35 TDH WATER BONDING FITTING PB -2008 1" UL LISTED 40YZ PERMA CAST COMPANY 3-WAY 3-WAY 3 WAY 3 WAY SALT CHLORINATOR 2" BLOWER 2" BLOWER RESIDENTIAL POOL NOTES: GOVERNING CODES and GENERAL NOTES: 2020 Florida Building Code (FBC), 7th Edition and all other codes, rules, regulations, and restrictions having jurisdiction on the project shall govern including FBC 7th Edition Building, Residential, Fuel Gas and Energy Conservation FBC 7th Edition Energy Conservation C404.2, Service Water Heating Equipment Performance Efficiency: Gas Pool Heaters 82%, Heat Pump 4.0 COP, shall be met for this project FBC 7th Edition Residential Chapter 45: Swimming Pools and Building Chapter 4, Section 454 Swimming Pools and Bathing Places (Public and Private) shall specifically govern FBC 7th Edition R4501.6.1 Conformance Standard: Design, construction and workmanship shall be in conformity with the requirements of ANSI/APSP/ICC 3; ANSI/APSP/ICC 4; ANSI/APSP/ICC 5; ANSI/APSP/ ICC 6; ANSI/APSP/ICC 7 FBC 7th Edition Building Chapter 4, Section 454.1.6.5.10.4 If the area is subject to high ground water, the pool shall be designed to withstand hydraulic uplift or shall be provided with hydrostatic relief devices. FBC 7th Edition Section 454.2.21.4 and R4501.21.4 Hydrostatic Relief Device. In areas of anticipated water table an approved hydrostatic relief device shall be installed FBC 7th Edition R4501.6.3 Water Velocity. Pool piping is designed so the water velocity will not exceed 10 feet per second for pressure piping and 8 feet per second for suction piping. Main suction outlet velocity must comply with ANSI/APSP/ICC 7. Exception: Jet inlet fittings shall not be deemed subject to this requiremet Concrete shall conform to the latest edition of ACI 301 and ACI 318, with minimum 28-day compressive strength of 3,500 psi. Pool concrete can be applied pneumatically and shall conform to the latest edition of ACI 506.2 Reinforcing Steel shall conform to the latest edition of ASTM A615, Grade 40 (#3, #4), Grade 60 (#5) and have a minimum lap distance of 18” for #3, 24” for #4 and 30” for #5 to meet the requirements of the latest edition of ACI 318. Discontinuous reinforcement bars shall terminate in standard ACI hooks. All hooks are standard unless otherwise noted FBC 7th Edition Building 1903.3 Glass Fiber Reinforced Concrete GFRC and the materials used in such concrete shall be in accordance with the PCI MNL 128 Standard, if shown on the drawings Pool Piping shall be N.S.F approved and minimum Schedule 40 NDPES: A silt fence and any other item, such as a construction entrance, with tire wash station shall be installed and inspected, if required, prior to construction surrounding the work area meeting the requirements of the AHJ OSHA 1926: Safety and Health Regulations for Construction shall be followed especially during open excavation and trenching Contractor shall be responsible to secure and protect all material brought on site, shall restore all areas impacted by the construction work to the preexisting condition or better and shall not impact drainage/lake, right of way or any other easements without consent Existing conditions, dimensions and quantities shall be field verified by Contractor prior to construction, as the Engineer has not been to the location. Typical field conditions are assumed in the design. Should anything differ from that specified herein or standard field conditions, additional engineering may be required and the Engineer shall be contacted to provide direction. Care shall be taken by Contractor in all applications of these drawings. The equipment and piping physical location may differ in the field due to unforeseen conditions or other factors. These drawings shall not be scaled, written dimensions shall take precedence. Contractor shall be responsible to locate and install items in a location that meets local codes These drawings are the property of Wayne Markham Bennett, P.E. Use of these drawings without permission from the Engineer is prohibited. The Engineer does not review the drawings for compliance with the agreement between Contractor and Homeowner. The Engineer is not responsible for any encroachment into easements or setbacks, even if approved by the AHJ. The Contractor shall verify compliance with setbacks and easements. The Engineer reviews the plans for code compliance to the best of his knowledge. Use of these drawings by the Contractor and Homeowner indemnifies and holds harmless the Engineer for all costs and damages including legal fees resulting from material fabrication, system erection and construction practices beyond which is called for Local, State and Federal Codes and from deviations of these plans except as expressly provided herein. The Engineer is not responsible for and has no liability for construction in setbacks or easements, and Contractor and/or Homeowner requirements and/or agreements related to the Pool and/or Spa. Regardless of cause, the Engineer’s Liability in relation to these plans is limited to the lesser of $500 or the fee charged by the Engineer for these plans. WARNING: To empty pool of water after construction for any reason, the hydrostatic uplift pressures beneath the pool must be eliminated to prevent the pool from floating upward. Owner must consult a pool contractor experienced in eliminating uplift pressure POOL EQUIPMENT and ANCHORING: Pool Equipment Elevation shall be at a minimum of the Design Flood Elevation (FBC 7th Edition Residential R322.1.4) plus 1 foot or according to the Authority Having Jurisdiction FBC 7th Edition Building 1620 HVHZ Wind Loads and 1621 HVHZ Overturning Moment and Uplift Pool Equipment shall be designed, constructed and installed to meet the requirements of ASCE 7. Equipment tie down shall be as follows, Heaters 4 total (1 per side or 2 per opposite sides); Others 2 total: 3-1/2” minimum thick, 3000 psi concrete slab, 3” larger than on each side than the equipment; ¼” diameter Tapcon® Concrete Screws (1600# tension, 1290# shear, 1-1/2” embedment in 2000 psi concrete) or equal with stainless steel fender washer into factory provided hold downs or 1” wide, 14 gauge galvanized straps with 2 stainless steel, #10 x ¾” Pan Head Phillips SS screws each strap into metal frame of equipment FBC 7th Edition Building 1907.1 General The thickness of concrete equipment slab supported directly on the ground shall not be less than 3 -1/2 inches thick and shall not require a vapor barrier. Equipment Location and Screening: The equipment and piping physical location may differ in the field due to unforeseen conditions or other factors. Contractor shall be responsible to locate and install items in a location that meets local zoning code and to provide code compliant landscape or fence screening SWIMMING BARRIER REQUIREMENTS: FBC 7th Edition Residential R4501.17 Residential Swimming Barrier Requirement Residential swimming pools shall comply with Sections R4501.17.1 through R4501.17.3. Exception: A swimming pool with an appro ved safety pool cover complying with ASTM F1346 FBC 7th Edition Residential R4501.17.1 Outdoor Swimming Pools Outdoor swimming pools shall be provided with a barrier complying with R4501.17.1.1 through R4501.17.1.14 A Swimming Barrier around the pool area that meets the above code is required prior to final pool structural inspection and filling of the pool FLOOD ZONE: FBC 7th Edition Residential R322 Flood-Resistant Construction structures constructed in whole or part in flood hazard areas shall be designed and constructed in accordance with the provis ions of this section, especially R322.1.2 Structural Systems, 322.1.3 Flood -Resistant Construction and R322.2.5 Pools in Flood Hazard Areas. If structures constructed in whole or part in floodways shall be designed and constructed in accordance with ASCE 24 and the construction of this pool will not increase the design flood elevation SOIL BEARING and FOUNDATION NOTES: No Piles and without Soil Report: FBC 7th Edition Building 1803 Geotechnical Investigations: The Building Official shall be permitted to waive the requirement. Allowable Bearing Capacity: Based on rational analysis through knowledge of other projects in the vicinity and a visual examination of the surface soil, finding sand and rock, the pool foundation has been designed assuming 2,000 psf soil bearing capacity per Table R401.4.1. If during excavation deleterious material (such as silt, peat, muck, clay, etc.) is found that cannot provide 2,000 psf, the Engineer shall be contacted to provide direction DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For:A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818-3825 / wayne@wmb-pe.com DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818-3825 / wayne@wmb-pe.com DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818-3825 / wayne@wmb-pe.com NOTES RESIDENTIAL POOL NOTES: GOVERNING CODES and GENERAL NOTES: 2020 Florida Building Code (FBC), 7th Edition and all other codes, rules, regulations, and restrictions having jurisdiction on the project shall govern including FBC 7th Edition Building, Residential, Fuel Gas and Energy Conservation FBC 7th Edition Energy Conservation C404.2, Service Water Heating Equipment Performance Efficiency: Gas Pool Heaters 82%, Heat Pump 4.0 COP, shall be met for this project FBC 7th Edition Residential Chapter 45: Swimming Pools and Building Chapter 4, Section 454 Swimming Pools and Bathing Places (Public and Private) shall specifically govern FBC 7th Edition R4501.6.1 Conformance Standard: Design, construction and workmanship shall be in conformity with the requirements of ANSI/APSP/ICC 3; ANSI/APSP/ICC 4; ANSI/APSP/ICC 5; ANSI/APSP/ ICC 6; ANSI/APSP/ICC 7 FBC 7th Edition Building Chapter 4, Section 454.1.6.5.10.4 If the area is subject to high ground water, the pool shall be designed to withstand hydraulic uplift or shall be provided with hydrostatic relief devices. FBC 7th Edition Section 454.2.21.4 and R4501.21.4 Hydrostatic Relief Device. In areas of anticipated water table an approved hydrostatic relief device shall be installed FBC 7th Edition R4501.6.3 Water Velocity. Pool piping is designed so the water velocity will not exceed 10 feet per second for pressure piping and 8 feet per second for suction piping. Main suction outlet velocity must comply with ANSI/APSP/ICC 7. Exception: Jet inlet fittings shall not be deemed subject to this requiremet Concrete shall conform to the latest edition of ACI 301 and ACI 318, with minimum 28-day compressive strength of 3,500 psi. Pool concrete can be applied pneumatically and shall conform to the latest edition of ACI 506.2 Reinforcing Steel shall conform to the latest edition of ASTM A615, Grade 40 (#3, #4), Grade 60 (#5) and have a minimum lap distance of 18” for #3, 24” for #4 and 30” for #5 to meet the requirements of the latest edition of ACI 318. Discontinuous reinforcement bars shall terminate in standard ACI hooks. All hooks are standard unless otherwise noted FBC 7th Edition Building 1903.3 Glass Fiber Reinforced Concrete GFRC and the materials used in such concrete shall be in accordance with the PCI MNL 128 Standard, if shown on the drawings Pool Piping shall be N.S.F approved and minimum Schedule 40 NDPES: A silt fence and any other item, such as a construction entrance, with tire wash station shall be installed and inspected, if required, prior to construction surrounding the work area meeting the requirements of the AHJ OSHA 1926: Safety and Health Regulations for Construction shall be followed especially during open excavation and trenching Contractor shall be responsible to secure and protect all material brought on site, shall restore all areas impacted by the construction work to the preexisting condition or better and shall not impact drainage/lake, right of way or any other easements without consent Existing conditions, dimensions and quantities shall be field verified by Contractor prior to construction, as the Engineer has not been to the location. Typical field conditions are assumed in the design. Should anything differ from that specified herein or standard field conditions, additional engineering may be required and the Engineer shall be contacted to provide direction. Care shall be taken by Contractor in all applications of these drawings. The equipment and piping physical location may differ in the field due to unforeseen conditions or other factors. These drawings shall not be scaled, written dimensions shall take precedence. Contractor shall be responsible to locate and install items in a location that meets local codes These drawings are the property of Wayne Markham Bennett, P.E. Use of these drawings without permission from the Engineer is prohibited. The Engineer does not review the drawings for compliance with the agreement between Contractor and Homeowner. The Engineer is not responsible for any encroachment into easements or setbacks, even if approved by the AHJ. The Contractor shall verify compliance with setbacks and easements. The Engineer reviews the plans for code compliance to the best of his knowledge. Use of these drawings by the Contractor and Homeowner indemnifies and holds harmless the Engineer for all costs and damages including legal fees resulting from material fabrication, system erection and construction practices beyond which is called for Local, State and Federal Codes and from deviations of these plans except as expressly provided herein. The Engineer is not responsible for and has no liability for construction in setbacks or easements, and Contractor and/or Homeowner requirements and/or agreements related to the Pool and/or Spa. Regardless of cause, the Engineer’s Liability in relation to these plans is limited to the lesser of $500 or the fee charged by the Engineer for these plans. WARNING: To empty pool of water after construction for any reason, the hydrostatic uplift pressures beneath the pool must be eliminated to prevent the pool from floating upward. Owner must consult a pool contractor experienced in eliminating uplift pressure POOL EQUIPMENT and ANCHORING: Pool Equipment Elevation shall be at a minimum of the Design Flood Elevation (FBC 7th Edition Residential R322.1.4) plus 1 foot or according to the Authority Having Jurisdiction FBC 7th Edition Building 1620 HVHZ Wind Loads and 1621 HVHZ Overturning Moment and Uplift Pool Equipment shall be designed, constructed and installed to meet the requirements of ASCE 7. Equipment tie down shall be as follows, Heaters 4 total (1 per side or 2 per opposite sides); Others 2 total: 3-1/2” minimum thick, 3000 psi concrete slab, 3” larger than on each side than the equipment; ¼” diameter Tapcon® Concrete Screws (1600# tension, 1290# shear, 1-1/2” embedment in 2000 psi concrete) or equal with stainless steel fender washer into factory provided hold downs or 1” wide, 14 gauge galvanized straps with 2 stainless steel, #10 x ¾” Pan Head Phillips SS screws each strap into metal frame of equipment FBC 7th Edition Building 1907.1 General The thickness of concrete equipment slab supported directly on the ground shall not be less than 3 -1/2 inches thick and shall not require a vapor barrier. Equipment Location and Screening: The equipment and piping physical location may differ in the field due to unforeseen conditions or other factors. Contractor shall be responsible to locate and install items in a location that meets local zoning code and to provide code compliant landscape or fence screening SWIMMING BARRIER REQUIREMENTS: FBC 7th Edition Residential R4501.17 Residential Swimming Barrier Requirement Residential swimming pools shall comply with Sections R4501.17.1 through R4501.17.3. Exception: A swimming pool with an appro ved safety pool cover complying with ASTM F1346 FBC 7th Edition Residential R4501.17.1 Outdoor Swimming Pools Outdoor swimming pools shall be provided with a barrier complying with R4501.17.1.1 through R4501.17.1.14 A Swimming Barrier around the pool area that meets the above code is required prior to final pool structural inspection and filling of the pool FLOOD ZONE: FBC 7th Edition Residential R322 Flood-Resistant Construction structures constructed in whole or part in flood hazard areas shall be designed and constructed in accordance with the provis ions of this section, especially R322.1.2 Structural Systems, 322.1.3 Flood -Resistant Construction and R322.2.5 Pools in Flood Hazard Areas. If structures constructed in whole or part in floodways shall be designed and constructed in accordance with ASCE 24 and the construction of this pool will not increase the design flood elevation SOIL BEARING and FOUNDATION NOTES: No Piles and without Soil Report: FBC 7th Edition Building 1803 Geotechnical Investigations: The Building Official shall be permitted to waive the requirement. Allowable Bearing Capacity: Based on rational analysis through knowledge of other projects in the vicinity and a visual examination of the surface soil, finding sand and rock, the pool foundation has been designed assuming 2,000 psf soil bearing capacity per Table R401.4.1. If during excavation deleterious material (such as silt, peat, muck, clay, etc.) is found that cannot provide 2,000 psf, the Engineer shall be contacted to provide direction DRAFTED BY: G.S.M.DESIGNER A Custom Pool Designed Especially For: 7/1/2021 IF SIGNED DIGITALLY ABOVE, PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES IF THERE IS A DIGITAL SIGNATURE ON THE FRONT/FIRST PAGE OF THIS FILE, THIS SHEET IS PART OF A DIGITALLY SIGNED FILE AND DOES NOT REQUIRE A SEPARATE DIGITAL SIGNATURE ON THIS SHEET WAYNE MARKHAM BENNETT P.E. #57216 MARKHAM SERVICES, INC. (CA 33018) 1820 NE JENSEN BEACH BLVD #685 JENSEN BEACH, FL 34957-7212 (954) 818-3825 / wayne@wmb-pe.com NOTES LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK LOCKE, BRAD 5345 S 25TH ST FT PIERCE, FL 34981 JK FOR POOL LOCATION ONLY EQUIPMENT EQUIPMENT 53'2"56'9"69'3"72'9"192'11" 187'11" FOR POOL LOCATION ONLY