HomeMy WebLinkAboutAPPROVED, Underlayment NOA 3 23 21 (1)CREEK Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT
FLORIDA BUILDING CODE, 7T" EDITION (2020)
Manufacturer:
DREXEL METALS, INC. Issued August 9, 2020
1234 Gardiner Lane
Louisville, KY 40213
(502) 716-7143
www.drexmet.com
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.1.1, 1507.2.4
Properties:
Physical properties
REFERENCES
EntitX
Report No. Standard Year
TrinitylERD (TST6049)
C41280.10.12 ASTM D 1970 2015a
ICC-ES (EVL2396)
ESR-2206 ASTM D 1970 2015a
PRODUCT DESCRIPTION AND APPLICATION
MetShield
MetShield is a coated-polyolefin-composite film surfaced, self -adhered ASTM D 1970
underlayment for use on steep slope roofs.
Deck Type:
Solid or closely fitted plywood sheathing for new or existing construction. Plywood
deck shall be installed in accordance with FBC requirements. Roof decks shall have
no more than 1/8" gap at abutting joints.
Min. slope:
In accordance with FBC requirements
Attachment method:
Underlayment shall be attached in accordance with the FBC Section 1507.1.1, Table
1507.1.1.1 and manufacturer's installation instructions.
Min. application temperature:
40°F. Contact the manufacturer when installing at temperatures below 40°F.
Allowable roof coverings:
Permitted to be used as prescribed in FBC Table 1507.1.1.1 with mechanically
fastened roof coverings.
DRX13004.3 FL16342-R3 Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
DREXEL METALS, INC.
MetShield
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) MetShield may be used as described in other current FBC product approval documents.
7) MetShield shall not be used with adhered tile roof coverings nor installed over existing roof coverings.
8) MetShield shall be exposed on the roof deck for a maximum duration of 30 days.
9) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 71h Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
IR
No 74021
O'.• STATE O F : �44/
SS�O N A1-E�``��
111111"
CERTIFICATION OF INDEPENDENCE
2020.08.09
�e�) 12 :3 0:46
pquy W.e •v ryrvn.PH-
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
DRX13004.3
END OF REPORT
FL16342-R3
2 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.