Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutInspection Card Y �
Inspection Card
Planning&Development Services Permit#: 1112-0261
Online address:
Building&;Code Regulation Division http://www.stlucieco:org/planning/permitting.htm
2300 Virginia Avenue Quick Links:
Fort Pierce,FL 34982 Permit Status Lookup
Phone:(772)462-2172 Fax:(772)462-6443 Online Building Inspection System
Page 1 of 5
Permit# SLC-1112-0261 Confirmation 791 Status FIN
Issued: 3/9/2012 Type: Building Residential(SFR)
Job Location: 5032 Watersong Way City: Fort Pierce
Jurisdiction: St Lucie County Parcel: 2532-500-0086-000/1
Subdivision: Watersong PUD Lot: 72 Block:
Flood: AE Elev: 6 Flood.Map: 194G
Set backs: Left: 6.00 Right: 6.00 Front: 10.00 Rear: 40.00
Job Description: New Construction Of A Single Family Residence,4 Bdrm 4.5 Bth-5,812 Sq Ft.'******6/7/12 All Gas'Piping Both
Inside And Out To Be Done Under Gas Tank Installation Permit[1204-0256] Dj
Contractor Mario P Arbucci -- Cert#27063 Oceanfront Builders Of The Treasure Coast Llc (772).219-2180
4331 Sw Thistle Terrace Palm City, FL 34990
Property Owner -Alexander Kress (772)219-2180
8610 Se Harbor Island Way Jupiter, FL 33458
Property Owner Donna Kress (772)219-2180
8610 Se Harbor Island-Way Jupiter, FL 33458
SUB-PERMITS
Permit No Status Permit Type Cert# DBA Owner/Builder Job Desc.
1112-0261-01 Finaled Electric-Residential 19629 Accurate Electrical Contracting Inc
1112-0261-02 Finaled Plumbing- 27366 Masters Plumbing Inc Of Martin
Residential County
1112-0261-03 Finaled Mech/HVAC-Don't
use this
Report prepared on 6/26/2013 10:59:30 AM
_ Inspection Card
Planning&Development Services Permit#: 1112-0261
Online address:
Building&,Code Regulation Division
hftp://www.stlucieco.org/plahning/permifting.htm
2300 Virginia Avenue Quick Links:
Fort Pierce,FL. 34982 Permit Status Lookup
Phone:(772)462-2172 Fax:(772)462-6443 Online Building Inspection System
Page 2 of 5
1112-0261-04 Finaled Roof-Fiberglass 23041 Code Red Roofers Inc 10-2-2012
Shingle CHANGE OF
ROOFING
SUB FROM
#23041
DOUGLAS
ROE TO#
27197 JESUS
VASQUEZ
PER LETTER
FORM MARIO
ARBUCCI
/CONTRACT
OR-A
HUMPHREY
6/26/2012
change roof
contractor
from cardinal
roofing#9072
to code red
roofers#
23041
1112-0261-06 Finaled Roof-Fiberglass 27197 All American Roofing&Coating Of
Shingle FI Inc
For the automated inspection system call(866)284-1280. To schedule an inspection online go to
http://c,odeinspectionpublic.stluciecagov. All inspections requested prior to 9:00 PM will be scheduled for the next business
day. Inspection requests between 9:00 PM Friday and 9:00 PM Monday will be scheduled for the following Tuesday. If you
require any assistance please contact the Building Department at(772)462-2172.
Inspection Notes: GATE CODE 9731
A SEPERATE PERMIT IS REQUIRED FOR LP GAS TANK INSTALLATION (DAVE JOHNSON)
Permit# Type Description Priority Sched.Date Res Description. Inspector Insp.Date
1112-0261 153 Insulation Certification 0 7/16/2012 90 Approved Dave Johnson 7/16/2012
Office
1112-0261 425 Sewer Connect 0 8/20/2012 91 Partial Approval Gary Scheigner 8/20/2012
CONTRACTOR TO DETERMINE PROPER LOCATION OF SEWER CONNECTION IN RELATION TO EXISTING TRANSFORMER
1112-0261 19.00M Planevi R ion 0 92 Accepted As Noted Dave Johnson 3/29I2'Ofi
�©RrCaNr/ER�NNG S1TlORAGE 1200M T O HABI�TABLE BATpH R®OM RND LAUN©R4ROOM
1112-0261 103 Eufer Ground 1 3/19/2012 90 Approved Dave Johnson 3/19/2012
1112-0261 104 Compaction Test-Original 1 3/29/2012 90 Approved Eileen Norton 3/29/2012
-Turn into Office
04/11/2012 ORIGINAL WITH RAISED SEAL SUBMITTED.EN
PARTIAL APPROVAL UNTIL ORIGINAL COPY WITH RAISED SEAL SUBMITTED.KA
bath conversion
1112-0261 105 Form Board Surrey- 1 3/29/2012 92 Accepted As Irvie Saunders 3/29/2012
Office Noted
Final survey required for columns at rear.
Report prepared on 6/26/2013 10:59:30 AM
Inspection Card
Planning&Development Services Permit#: 1 61
Building&,Code Regulation Division Online addrr ess:ess:
hftp://www.stiucieco.org/planning/permifting.htm
2300 Virginia Avenue Quick Links:
Fort Pierce,FL. 34982 Permit Status Lookup
Ohone:(772)462-2172 Fax:(772)462-6443 Online Building Inspection System
Page 3 of 5
1112-0261 106 Engineers Report-Original- 1 92 Accepted As Dave Johnson 3/30/2012
Turn into office Noted
AUGERCAST PILE REPORT--RECEIVED AND FILED DJ***
1112-0261 115 Slab 1 3/30/2012 90 Approved Gary Scheigner 3/30/2012
1112-0261 115 -Slab 1 5/31/2012 75 Cancelled,by Gary Scheigner 5/31/2012
Customer
FOR PROPANE SLAB.EN
1112-0261 115 Slab 1 5/31/2012 75 Cancelled by Gary Scheigner 5/31/2012
Customer
Re-inspection 2
1112-0261 115 Slab 1 6/4/2012 90 Approved Gary Scheigner 6/4/2012
Re-inspection 3
1112-0261 121 Termite Spray 1 3/30/2012 90 Approved Gary Scheigner 3/30/2012
bath conversion
1112-0261 129 Pile Cap 1 3/30/2012 90 Approved Gary Scheigner 3/30/2012
FOR GADE BEAM/PILE CAP
1112-0261 137 Strapping 1 6/4/2012 90 Approved Gary Scheigner 6/4/2012
1112-0261 145 Truss Drvrg 1 6/4/2012 90 Approved Gary Scheigner 6/4/2012
1112-0261 420 Plumbing Rough 1 3/19/2012 90 Approved Dave Johnson 3/19/2012
1112-0261 420 Plumbing Rough 1 3/29/2012 90 Approved Gary Scheigner 3/29/2012
Bath conversion
1112-0261 427 Temp.Toiletfremp Culvert 1 3/19/2012 90 Approved Dave Johnson 3/19/2012
1112-0261 118 Column 3 4/12/2012 90 Approved Gary Scheigner 4/12/2012
FIRST FLOOR
1112-0261 121 Termite Spray 3 4/12/2012 90 Approved Gary Scheigner 4/12/2012
DONE ON THE 3-30-2012 SLAB INSPECTION
1112-0261 125 Tie Beam 3 4/12/2012 90 Approved Gary Scheigner 4/12/2012
FIRST FLOOR
1112-0261 106 Engineers Report-Original- 4 5/1/2012 90 Approved Gary Scheigner 5/1/2012
Turn into office
FOR HOLLOW CORE SHORING 2nd floor
1112-0261 118 Column 4 5/1/2012 90 Approved Gary Scheigner 5/1/2012
1112-0261 122 Flood Elev Cert Under 4 92 Accepted As Dave Johnson 4/2/2012
Construction-Office Noted
1112-0261 126 2nd Floor Tie Beam 4 5/1/2012 90 Approved Gary Scheigner 5/1/2012
1112-0261 906 Batch Tickets(Concrete)- 4 5/1/2012 90 Approved Gary Scheigner 5/1/2012
Turn into Office
FOR SLAB/GRADE BEAMS 3000 PSI
1112-0261 906 Batch Tickets(Concrete)- 4 5/1/2012 90 Approved Gary Scheigner 5/1/2012
Turn into Office
FOR 1ST FLOOR COLUMN/BEAM 3000 PSI
1112-0261 106 Engineers Report-Original- 5 5/24/2012 90 Approved Gary Scheigner 5/24/2012
Turn into office
FOR SHORING 3rd FLOOR HOLLOW CORE SYSTEM RECD DATED 5-8-2012
1112-0261 118 Column 5 5/1/2612 90 Approved Gary Scheigner 5/1/2012
2ND FLOOR
1112-0261 125 Tie Beam 5 5/24/2012 90 Approved Gary Scheigner 5/24/2012
Report prepared on 6/26/2013 10:59:30 AM
Inspection Card
Planning&Development Services Perm it#: 1112-0261
Building&.Code Regulation Division online address:
http://www.stiucieco.org/planning/permitting.htm
2300 Virginia Avenue Quick Links:
Fort Pierce,F.L. 34982 Permit Status Lookup
Phone:(772)462-2172 Fax:(772)462.6443 Online Building Inspection System
Page 4of5
TOP OF WALL—TOP FLOOR BEAM
1112-0261 134 Roof Sheathing 5 5/25/2012 90 Approved Gary Scheigner 5/25/2012
1112-0261 906 Batch Tickets(Concrete)- 5 5/24/2012 90 Approved Gary Scheigner 5/24/2012
Turn into Office
FOR 2ND FLOOR COLUM/BEAM 3000 PSI
1112-0261 .906 Batch Tickets(Concrete)- 5 5/24/2012 90 Approved Gary Scheigner 5/24/2012
Turn into Office
FOR TOP COLUMN/BEAM 3000PSI
1112-0261 133 Window/Door Bucks 7 6/7/2012 90 Approved Gary Scheigner 6/7/2012
1112-0261 136 Roof Dry-in/Tin Tab 7 6/4/2012 90 Approved Gary Scheigner 6/4/2012
1112-0261 108 Engineer Letter-Original- 8 6/25/2012 90 Approved Gary Scheigner 6/25/2012
turn into office
FOR GROUTED MASONRY INSPECTION PER MASONRY NOTES PAGE A A1.1
1112-0261 127 Mullion 8 6/25/2012 90 Approved Gary Scheigner 6/25/2012
1112-0261 136 Roof Dry-in/Tin Tab 8 6/29/2012 90 Approved Gary Scheigner 6/29/2012
PARTIAL-PEEL&STICK FOR FLAT ROOF
1112-0261 141 Insulation 8 7/16/2012 90: Approved Dave Johnson 7/16/2012
null
Resulted: Mon Jul 16 12:03:04 EDT 2012
1112-0261 148 Window/DdorAttachment 8 6/25/2012 90 Approved GaryScheigner 6/25/2012
1112-0261 259 Power Release Form(30 8 8/6/2012 90 Approved Eileen Norton 8/6/2012
day for testing)Office
1112-0261 260 30 Day for Testing 8 8/8/2012 71 Rollo ver to Next Walter Pride 8/7/2012
1112-0261 260 30 Day for Testing 8 8/8/2012 81 Disapproved Walter Pride 8/8/2012
Re-inspection 1
1112-0261 260 30 Day for Testing 8 8/16/2012 90 Approved Walter Pride 8/16/2012
Re-inspection 2
1112-0261 456 Fire Sprinkler Rough 8 75 Cancelled by
Customer
1112-0261 456 Fire Sprinkler Rough 8 6/27/2012 90 Approved Rick Hamner 6/27/2012
Re-inspection.1
1112-0261 490 Rough Gas(Inside) 8 6/29/2012 90 Approved Gary Scheigner 6/29/2012
SEE PERMIT 1204-0256
1112-0261 650 Frame-all 8 6/1/2012 90 Approved Gary Scheigner 6/29/2012
1112-0261� 167 Roof Final 9 9/7/2012 90 Approved Gary Scheigner 9/7/2012
1112-0261 181 Elevator Certification 9 92 Accepted As Dave Johnson 9/20/2012
Noted
RECEIVED AND FILED
1112-0261 425 Sewer Connect 9 10/3/2012 90 Approved Gary Scheigner 10/3/2012,
Re-inspection 1 PICTURES ON FILE
1112-0261 457 Fire Sprinkler Final 9 10/5/2012 90 Approved Brian Putnam 10/5/2012
FD TO INSPECT
1112-0261 493 Final Gas 9 92 Accepted As Noted Dave Johnson 10/17/2012
SEE PERMIT 1204-0256
Report prepared on 6/26/2013 10:59:30 AM
Q Inspection Card
Planning&Development Services Permit#: 1 61
Building S,Code Regulation Division Online addrr ess:ess:
http://www.stlucieco.org/planning/permitting.htm
2300 Virginia Avenue Quick Links:
Fort Pierce,FL. 34982 Permit Status Lookup
Phone:(772)462-2172 Fax:(772)462.6443 Online Building Inspection System
Page 5of5
1112-0261 996 Final Termite Treatment-
Turn into office g 10/8/2012 90 Approved Eileen Norton 10/8/2012
PER AFFIDAVIT SUBMITTED.
1112-0261 130 . Flood Elev Final Const 10 92 Accepted As Dave Johnson 10/25/2012
Certif-Office Noted
RECEIVED AND FILED
.1112-0261 167 Roof Final 10 10/18/2012 90 Approved Gary Scheigner 10/18/2012
9-25-2012 roof was previously finaled but roof is now leaking-new roofing sub was hired to repair previous roof-avid Johnson
1112-0261 261. 30 Day Expired 10 10/18/2012 93 Not Required
1112-0261 800 Address Final 10 10/18/2012 90 Approved Gary Scheigner 10/18/2012
1112-0261 804 Driveway Bldg 10 10/18/2012 90 Approved Gary Scheigner 10/18/2012
1112-0261 999 Final Inspection 10 10/18/2012 91 Partial Approval Gary Scheigner 10/18/2012
OK TO FINAL ONCE WE APPROVE FINAL FLOOD CERT
1112-0261 999 Final Inspection 10 99 Final Approval Gary Scheigner 10/25/2012
Re-inspection 1 OK TO FINAL ONCE WE APPROVE FINAL FLOOD CERT
Total Inspections: 61
Report prepared on 6/26/2013 10:59:31 AM