HomeMy WebLinkAboutRevision- water heater OFFICE USE ONLY:
DATE FILED: PERMIT# /0(./
REVISION FEE: RECEIPT#
PLANNING& DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772)462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:17-,(2
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
c
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: C /1J� _ ST. LUCIE CO CERT. #:
BUSINESS NAME: I
QUALIFIERS NAME: rf-
ADDRESS:- v.
CITY: ZSTATE: L ZIP: 3
PHONE(DAYTIME): ���_-�/ — 3r_ FAX:
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
SLCCC: 9/23/09 REVISIUN
Revised 06130/17
t
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: MICHAEL FOSTER BuilderName:
Street: 176 ESTEIA LANE Permit Office:
City,State,Zip: PORT ST.LUCIE,FL, PermitNumber:
Owner: Jurisdiction:
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing Addition 9. Wall Types (1224.0 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1224.00 ftZ
b.N/A R= ftZ
3. Number of units,if multiple family 1 c.N/A R= ftZ
4. Numberof Bedrooms(BedrmslnAddition) 3(0) d.N/A R= ftZ
5. Is this a worst case? No 10.Ceiling Types (1162.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1162.00 ftZ
6.Conditioned floor area above grade(ftZ) 1162 b.N/A R= ftZ
Conditioned floor area belowgrade(ftZ) 0 c.N/A R= ftZ
11.Ducts R ftZ
7. Windows(252.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:A/C 6 85
a. U-Factor: Sgl,U=1.10 252.00 ftZ
SHGC: SHGC=0.39
b. U-Factor: N/A ftZ 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 24.6 SEER:16.00
c. U-Factor: N/A ftZ
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftZ a.Electric Strip Heat 27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 6.114 ft.
Area Weighted Average SHGC: 0.390 14.Hot water systems -
8. Floor Types (1162.0 sqft.) Insulation Area a.Electric Tankless Cap:1 gallons
EF:0.660
a.Slab-On-Grade Edge Insulation R=0.0 1162.00 ftZ b.Conservation features
b.N/A R= ftZ None
c.N/A R= ftZ 15.Credits CF,Pstat
Glass/Floor Area: 0.217 Total Proposed Modified Loads: 44.31 PASS
Total Baseline Loads: 44.58
I hereby certify that the plans and specifications covered by Review of the plans and -oiE Srq?,
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: �Q�*�� Before construction is completed C4 1 `
DATE: 9-26-2021 this building will be inspected for 0
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes. , 5�
with the Florida Energy ode. CDD I4�
OWNER/ T: � BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
9/26/2021 10:49 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant SorXVIryTO i„of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: MICHAEL FOSTER Bedrooms: 3 Address Type: StreetAddress
Building Type: User ConditionedArea: 1162 Lot#
OwnerName: Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
BuilderName: RotateAngle: 0 Street: 176 ESTEIA LANE
Permit Office: CrossVentilation: No County: St.Lucie
Jurisdiction: Whole House Fan: No City,State,Zip: PORT ST.LUCIE,
FamilyType: Detached FL,
New/Existing: Addition
Comment:
CLIMATE
/ Design Temp Int Design Temp Heating Design DailyTemp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 1162 10458
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 BATH 76 684 No 0 1 Yes Yes Yes
2 BEDROOM 2 220 1980 No 0 1 1 Yes Yes Yes
3 BEDROOM 1 180 1620 No 0 1 1 Yes Yes Yes
4 BED 3 108 972 No 0 1 1 Yes Yes Yes
5 KITCHEN 121 1089 Yes 0 1 Yes Yes Yes
6 LIVING AREA 240 2160 No 0 1 Yes Yes Yes
7 LIVING 211 1899 No 0 1 Yes Yes Yes
8 A/C 6 54 No 0 1 No Yes Yes
FLOORS
# FloorType Space Perimeter Peri mete rR-Value Area JoistR-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulation BATH 15 ft 0 76 ft2 ---- 0 1 0
2 Slab-On-Grade Edge Insulation BEDROOM 2 32 ft 0 220 ft2 ---- 0 1 0
3 Slab-On-Grade Edge Insulation BEDROOM 1 27 ft 0 180 ft2 ---- 0 1 0
4 Slab-On-Grade Edge Insulation BED 3 9 ft 0 108 ft2 ---- 0 1 0
SSlab-On-Grade Edge Insulation KITCHEN 22ft 0 121ft2 ---- 0 1 0
6 Slab-On-Grade Edge Insulation LIVING AREA 34 ft 0 240 ft2 ---- 0 1 0
7Slab-On-Grade Edge Insulation LIVING 13ft 0 211ft2 ---- 0 1 0
BSlab-On-Grade Edge Insulation A/C 1 ft 0 6ft2 ---- 0 1 0
9/26/2021 10:49 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Compositionshingles 1225 ft2 0 ft2 Light N 0.5 No 0.7 No 0 18.4
/ ATTIC
v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 1162 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) BATH 30 Blown 76ft2 0.1 Wood
2 Under Attic(Vented) BEDROOM 2 30 Blown 220 ft2 0.1 Wood
3 UnderAttic(Vented) BEDROOM 1 30 Blown 180ft2 0.1 Wood
4 Under Attic(Vented) BED 3 30 Blown 108 ft2 0.1 Wood
5 Under Attic(Vented) KITCHEN 30 Blown 121 ft2 0.1 Wood
6 Under Attic(Vented) LIVING AREA 30 Blown 240 ft2 0.1 Wood
7 Under Attic(Vented) LIVING 30 Blown 211 ft2 0.1 Wood
8 UnderAttic(Vented) A/C 30 Blown 6ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
Sorrafo
1 Exterior Concrete Block-Int Insul BATH 4.1 8 0 9 0 72.0 ft2 0 0 0.3 0
2 Exterior Concrete Block-Int Insul BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0
3 Exterior Concrete Block-Int InsuBEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0
4 Exterior Concrete Block-Int InsuBEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0
5 Exterior Concrete Block-Int InsuBEDROOM 1 4.1 15 0 8 0 120.0 ft2 0 0 0.3 0
6 Exterior Concrete Block-Int InsuBEDROOM 1 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0
7 Exterior Concrete Block-Int Insul BED 3 4.1 9 0 8 0 72.0 ft2 0 0 0.3 0
8 Exterior Concrete Block-Int Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0
9 Exterior Concrete Block-Int Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0
10 Exterior Concrete Block-Int Insi1LIVING AREA 4.1 24 0 8 0 192.0 ft2 0 0 0.3 0
11 Exterior Concrete Block-Int InsLILIVING AREA 4.1 10 0 8 0 80.0 ft2 0 0 0.3 0
12 Exterior Concrete Block-Int Insul LIVING 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0
DOORS
# Ornt DoorType Space Storms U-Value Width Height Area
Ft In Ft In
1 Insulated LIVING AREA None .28 3 7 21 ft2
2 Insulated LIVING None .28 3 7 21 ft2
9/26/2021 10:49 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening
1 1 Metal Low-ESingle Yes 1.1 0.39 Y 9.0 ft2 2 ft 0 in 1 ft 4 in None None
2 3 Metal Low-ESingle Yes 1.1 0.39 Y 11.7 ft2 2 ft 0 in 1 ft 4 in None None
3 4 Metal Low-E Single Yes 1.1 0.39 Y 11.3 ft2 2 ft 0 in 1 ft 4 in None None
4 4 Metal Low-ESingle Yes 1.1 0.39 Y 23.3 ft2 2 ft 0 in 1 ft 4 in None None
5 5 Metal Low-ESingle Yes 1.1 0.39 Y 11.7 ft2 2 ft 0 in 1 ft 4 in None None
6 5 Metal Low-ESingle Yes 1.1 0.39 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None
7 6 Metal Low-ESingle Yes 1.1 0.39 Y 11.7 ft2 2 ft 0 in 1 ft 4 in None None
8 7 Metal Low-ESingle Yes 1.1 0.39 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None
9 7 Metal Low-ESingle Yes 1.1 0.39 Y 12.3 ft2 2 ft 0 in 1 ft 4 in None None
10 8 Metal Low-ESingle Yes 1.1 0.39 Y 9.0 ft2 2 ft 0 in 1 ft 4 in None None
11 10 Metal Low-ESingle Yes 1.1 0.39 Y 11.7 ft2 12 ft 0 in 1 ft 4 in None None
12 10 Metal Low-ESingle Yes 1.1 0.39 Y 12.0 ft2 12 ft 0 in 1 ft 4 in None None
13 10 Metal Low-ESingle Yes 1.1 0.39 Y 80.0 ft2 12 ft 0 in 1 ft 4 in None None
14 12 Metal Low-ESingle Yes 1.1 0.39 Y 12.0 ft2 2 ft 0 in 1 ft 4 in None None
15 12 Metal Low-ESingle Yes 1.1 0.39 Y 12.3 ft2 2 ft 0 in 1 ft 4 in None None
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse ProposedACH(50) .000286 871.5 47.81 89.76 .0946 5
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/None(Basel None 27 kBtu/hr 1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/None(Baseline as Split SEER:16 24.6 kBtu/hr cfm 0.8 1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric Tankless BATH 0.66 1 gal 60.9gal 120deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # CompanyName System Model# Collector Model# Area Volume FEF
None None ft2
9/26/2021 10:49 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
----Supply--- ----Return-- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool
1 Attic 6 85 ft2 Attic 35 ft2 DefaultLeakage A/C (Default)c(Default)c 1 1
TEMPERATURES
ProgramableThermostat: Y Jan Feb [ ] Ceiling Fans: Jun [ ] rj
[ ]
Coolin
Heating Oct Nov De
Jan H Feb [X]Mar Apr I i May ri Jun ri Jul AurX Sep Oct Oct l Nov Dec
Venting Nov Dec
Jan Feb X Mar Jun [ ]Jul Aug [ ]Sep
ThermostatSchedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8lbs/sq.ft. 0 ft2 Oft 0.3 BATH
Default 8lbs/s .ft. ft2 ft 0.3 BEDROOM 2
( Q
Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 1
Default(8lbs/sq.ft. ft2 ft 0.3 BED 3
Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN
Default(8lbs/sq.ft. ft2 ft 0.3 LIVING AREA
Default(8lbs/sq.ft. ft2 ft 0.3 LIVING
Default 8lbs/s .ft. ft2 ft 0.3 A/C
9/26/2021 10:49 AM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
4
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*= 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. Addition 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Detached or multiple-family 2. Detached b) Return ducts R 6.0
c)AHU location A/C
3. No.of units (if multiple-family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.6
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1162 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a) U-f actor:(weighted average) 7a. 1.100
b) Solar Heat Gain Coefficient(SHGC) 7b. 0.390 14. Heating system: Capacity 27.0
c)Area 7c. 252.0 a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights c) Electric resistance COP 1.0
a) U-f actor:(we ighted average) 8a. NA d) Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE
f)Other
9. Floor type, insulation level:
a)Slab-on-grade (R-value) 9a. 0.0
b)Wood, raised (R-value) 9b. 15. Water heating system
c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.66
b)Gas fired, natural gas EF
10.Wall type and insulation: c) Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B. Adjacent: g)Other
1. Wood frame (Insulation R-value) 10131.
2. Masonry(Insulation R-value) 10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level a)Ceiling fans Yes
a) Under attic 1la. 30.0 b) Cross ventilation No
b) Single assembly 11b. c)Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 176 ESTEIA LANE City/FL Zip: PORT ST. LUCIE, FL
9/26/2021 10:49:43 AM EnergyGaugeO USA 7.0.01 -FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MICHAEL FOSTER Builder Name:
Street: 176 ESTEIA LANE Permit Office:
City,State,Zip: PORT ST.LUCIE,FL, Permit Number: Y
Owner: Jurisdiction: Lu
Design Location: FL,Fort Pierce 0
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceiling/attic nsu n any dropped g
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation i d ed ceiling/soffit
/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spa s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the drywall. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Pytp.nd behind nonong and wiring-
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub-floor or drywall.
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sr)r*nkler cover olates and walls or cemlinas.
a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
9/26/2021 10:49 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1