Loading...
HomeMy WebLinkAboutProduct Approval MAX FL17022.01- R8 p R IEVV `UH E XT R E M E M E TA L CODE COMPLIANCE FABRICATORS ST, LUCIE COUNTY SKILLED CRAFTERS OF METAL ROOFING SYSTEMS ^0 C. r 1 J/ / 26ga ( min ) ".. MAX over 15/32 (min ) plywood Extreme Metal Fabricators 2120 SW Poma Dr I Palm City FL 34990 Product Description 5V Crimp style exposed fastener panel with 24 max coverage and nominal rib height of 3/8 Product Material 26ga (min) steel Corrosion resistant per FBC 1507.4.3 where required Fastener #9 or #10 x 1.5 fastener with sealing washer Compliant with FBC 1506.6 where required. Substrate/ Deck 15/32 (min) plywood or 3/4 (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 1 Gainesville FL FL PE 81377 1 FL CA 33344 www.TimberLakeCove.com E. Fti David E Eng — No.81377 i 2020.10.06jFV - 00:08:33+01'00= * * _ STATE OF (C7441� ."40R10P.•' G\�� /0NAk-I�? digitally copiesand sealed by D.E Eng,PE,on the date indicated. Printed VM .. •.AX and sealed and the signature must be d on any electronic copies • Ex posed Sea MAX FL17022.01- R8 Underlayment: Comply with local building code or FBC 1507.1.1 where required. Slope: Comply with local building code or FBC 1507.4.2 where required. Re-Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511, provided the existing roof meets the conditions required by the applicable code. Maximum Allowable Loads & Installation Requirements: Method A: #9 x 1.5 fastener in 12 -12 pattern at 16 o.c.: 86 PSF Method B: #10 x 1% fastener in ft -V2 pattern at f'6 o.c.: 93.5 PSF Method C• #10 x 1 T fastener in 12' -12' pattern at 8"o.c.: 101 PSF Method D• #10 x 1.1 fastener in If -12' pattern at 6' o.c.: 228 PSF A factor of safety"of 2 has been applied. " Technical Documentation: This product has been tested to the UL 580 standard by Architectural Testing (now Intertek Testing, TST-1527), report D05893.01-450-18, F3366.01-450-18, and D05893.02-450-18. As referenced in FL 17022.01-R7 Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ) as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: • Enclosed and conforms to wind-borne debris provisions and is a regular shaped building • Is not subject to across-wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated weathering/salt spray is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Installation shall be subject to the local building code and authority having jurisdiction; this report shall not be construed to supersede local codes in force. EXTREMEMETALFABRICATORS.Com r, File, Cori-, NCSUCK Engineering SpL=a1c51ty Structural EnglnPerinQ CBUCK,Inc C i Jcate of Authorization#8064 CODE COMPLIANCE Evaluation Report ST. LJBOCC CIE COUNTY "Ultra HT Wind & Water SealT""" VI,-g1zf Roof Underlayment Manufacturer: MFM Building Products Corp. S2S Orange Street Coshocton, Ohio 43812 (740) 622-2645 for Florida Product Approval # FL 11842.3 R8 Florida Building Code 7th Edition (2020) Method: 1 - D Category: Roofing Sub - Category: Underlayment Product: "Ultra HT Wind & Water Seal'""' Description: Self-Adhered Underlayment Prepared by: James L. Buckner P.E. SECB This item has been electronically signed and sealed by i James L.Buckner,V.E.,on this date using a Digital Signature. Florida Professional Engineer#31242 Printed copies of this document are not considered signed and sealed, and the signature must be verified on any Florida Evaluation ANE ID: 1916 electronic copies. \\\\\\11111JJJ�// Project Manager: Diana Galloway \��•��s L: au!' Report No. 20-229-UHT-ER \\GENSF .�t•Fp (Revises 17-131-UHT-ER,FL11842.5 R4) * No 31242 Date: 08/28/20 = * U= �0,� STATE OF Contents: %,1$� •"_LORIDP'.•' �\?\ Evaluation Report Pages 1—5 2020.09.17 13:23:17-04'00' CBUCK,Inc.dba CBUCK Engineering Phone:(561)491-9927•Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net Business:1374 Community Dr.,Jupiter,FL 33458•Corp/Mailing:2637 E.Atlantic Blvd,#34069,Pompano Beach,FL 33062 I FL#: FL 11842.3 R8 "N Date: 08/28/20 CBUCK Engineering Page Report No.: 20-22 of 59 UHT-ER Specialty Structural Engtneprinq CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 www.mfmbp.com Product Name: "Ultra HT Wind&Water SeaITM11 Product Category: Roofing Product Sub-Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product Description: "Ultra HT Wind & Water SeaITM" is self-adhering membrane composed of a white, non-slip cross-laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner designed for use as a roof underlayment in high temperature conditions. Product Material/ Material Type: Styrene Butadiene Styrene (SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 7th Edition (2020), Chapter 15. i Product Dimension(s) Roll Size: 36 in.x 67 ft. rolls Thickness:45 mils(nominal) Substrate(s): "Ultra HT Wind & Water SeaITM" has been evaluated for application to the following substrates (Design of support is outside the scope of this evaluation): • Plywood • Dens Deck Installation: General Installation Instructions: "Ultra HT Wind &Water SeaITM" shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 7th Edition (2020), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. FL#: FL 11842.3 R8 Date: 08/28/20 CBUCK E=nginL=Prinq Report No.: 3 20-22 59 UHT-ER Page Speclaffiy Structural Engtneerinq CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • ASTM D 1970-15a — Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-15a standard version adopted by the Florida Building Code 6+th Edition (2020)for use as evaluated in this report. Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Product Limitations and • Deck shall be in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Evaluated for use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. Installation shall comply with FBC Section 1507.1.1. • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. General Limitations and . Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval'. • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is 1 FL#: FL 11842.3 R8 Date: 08/28/20 CBUCK E=ncginL=Prinq Page Report No •4 -22 59 UHT-ER Sp=ClC51W Structural EnglnPprinq CBUCK,Inc.Certificate of Authorization#8064 not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID#TST 1556) Report No. MFM-039-02-01, Date: 8/15/13 2. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID#QUA 1824) MFM Building Products Corp. Licensee#335 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916)