Loading...
HomeMy WebLinkAboutCompaction TestFLCl A,.. EVGINEERING & TESTING, INC. "'tw ;y `, Phone:4866) 781-6889`•Fax: (860) 784-8550 r w+ =, r: w`«•.floridaengineeringandtesting.com 250 S.W.13`n Avenue Pompano Beach, FL 33069 ' PROCTOR COMPACTSOiV TEST DATE SAMPLED: 11/26/2093 DATE'TESTED: 11/27/2013 ORDER #: 13-3498 CLIENT: W.H. McComb, Inca ADDRESS: 9360 Listow Terrace Boynton Beach, Florida 33437 PROJECT: Proposed New Residence ADDRESS: 4804 Watersong Way.,. Jensen Beach, Florida MATERIAL DESCRIPTION: Gray Sand and Shell Fragments SAMPLED BY: W.G. TESTED BY: P.T. SPECIFICATION GOVERNING: ASTM D-1557 LAB NO: P-3498 RESULTS OF TEST: The following compaction test was conducted in accordance with the Standard Methods of Moisture Density Relations of soil using a 10 lb. Hammer and an 18" drop as per the above specified method. MOISTURE % WET DENSITY (PCF) DRY DENSITY (PCF) 7.6 117.2 108.9 -9.6 122'.7 112.0 11.6 127.1 113.9 13.9 124.7 109.5 Optimum Moisture (Percentage): 115 12.5 % 114 113 Maximum Dry Density (Ibs./cuff) 113.9 (PCF) a 112 111 Respectfully Submitted, 0 110 109 ).1 -L 7 108 Reza J vid , P.E. Florida Engineering & Testing, Inc. 107 Florida -Reg. No: 60223 7 8 9 10 11 12 13 14 15 Certificate of Authorization No. 6923 MOISTURE % As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. Y !'f ,►�11 �catity `tj1\`A�r,flssttrauce FL ENGINEERING & TESTING, INC. :Q Phone: (866) 781-6889 *Fax: (866) 784-8550 www.floridaenginceringandtesting.com r„ 250 S.W.13"' Avenue Pompano Beach, FL 33069 REPORT OF FIELD COMPACTION TESTS DATE: 11/26/13 ORDER NO: 13-3498 PERMIT NO. CLIENT: W.H. McComb, Inc. ADDRESS: 9360 Listow Terrace Boynton Beach, Florida 33437 PROJECT: Proposed New Residence ADDRESS: 4804 Watersong Wu Jensen Beach, Florida MATERIAL DESCRIPTION: Gray Sand and shell Fragments PROCTOR VALUE (PCF): 113.9 % COMPACTION REQ'D BY SPECS: 95 NUCLEAR GAUGE SERIAL 9: ❑ 29793 (Model 3440) PROCTOR METHOD: ® ASTM D-1557 ❑ ASTM-13698 OPTIMUM MOISTURE (%): 12.5 LABORATORY NO: P-3498 ❑ 533 (Model 3450) ® 20500 (Model 3440) ❑ AASHTO T-180 ❑ AASHTO T-99 ASTM D 6938 METHOD AX Test 0 Location Lift Elev./ Dry Density Moisture Percent Compaction Pass/ Depth of Test ("�o) Fail Center of Garage (12" Above Natrual 1 Grade SOG 0" to -12" 113.7 10.1 99.8 P 10' E. of NE Corner of Garage (40" 2 Above Natural Grade SOG 0" to -12" 110.3 4.6 96.8 P Center of N. Wall (24" Above Natural 3 Grade SOG 0" to -12" 111.4 10.1 97.8 P 8' W. of SE Corner of Main House Slab 4 40" Above Natural Grade SOG 0" to -12" 110.4 4.7 96.9 P Center of E. Porch (36" Above Natural 5 Grade SOG 0" to -12" 109.0 10.6 95.7 P 6 7 8 REMARKS: TESTED BY: S.L. CHECKED BY: P.T. Notes: * Method A - Direct Transmission unless otherwise noted. PR - Proof Roll TOB - Top of Base SOG - Slab on Grade As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. 1X Q �l Quality La A 01 ✓ murance --r 1 Respectfully submitted, JJ�17//7 RE A AN, P.E. Flor a Engineering & Testing, Inc. Florida Reg. No. 60223 Certificate of Authorization No. 6923