Loading...
HomeMy WebLinkAboutEnergy CodeFORM 405-10 #1301 0228 FLORIDA ENERGY EFFICIEN VICO E FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WA . G - AA-KRAUS Street: t Builder Name: W.H. McCOMB CONSTRUCTI ;-r. �. Permit Office: ST. LUCIE CO. j'� �'�p' 3 City, State, SLUCIE CO., FL , Owner: KRR Permit Number: Jurisdiction: 661000 1, Desl tion: fierce �l� 1. New�oconst ion or existing New (From Plans) 9. Wall Types (5137.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=14.0 4675.40 ft2 b. Frame -Wood, Exterior R=11.0 462.00 ft2 3. Number of units, if multiple family 1 c. N A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1583.0 sqft.) Insulation Area a. Cathedral/Single Assembly (Unvented) R=20.0 1583.00 ft2 6. Conditioned floor area above grade (ft2) 3317 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(851.6 sqft.) Description Area a. Sup: 1st2nd Floors, Ret: 1st 2nd Floors, AH: 1st 6 311 a. U-Factor: Sgl, U=0.99 292.26 ft2 b. Sup: 3rd Floor, Ret: 3rd Floor, AH: 3rd Floor 6 290 SHGC: SHGC=0.25 b. U-Factor: Sgl, U.=1.01 290.95 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 42.0 SEER:18.00 c. U-Factor: Sgl, U=1.09 268.42 ft2 b. Central Unit 35.0 SEER:18.00 . SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 6.340 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems o ' `8. Floor Type§ (1786:8 sgft.) Insulation Area a. Propane Cap: 80 gallonsEF:0.590 a:"Floorover-Garage R=19.0 1230.50 ft2 b. Conservation features b'. Slab-On-Grd'd' "Edge i6sui` tioi, - R=0.0 290.00 ft2 None c. other (see details) R= 266.30 ft2 15. Credits Pstat Glass/Floor Area: 0.25:7_�'. ' Total Proposed Modified Loads: 64.40 PASS Total Standard Reference Loads: 84.52 • `� �p I hereby certify that the plaris`and specifications covered by Review of the plans and &VIE Sr4 this calculation are in compliance with the Florida Energy specifications covered by this O 'y _ 0 04, Code. calculation indicates compliance y;v` �f' _ =��..�` with the Florida Energy Code. +� u.:. n,., •r rrM. PREPAR D BY: �lM�I�eS E CAms Before construction is completed DATE: --I g -1 7 this building will be inspected for compliance with Section 553.908 ' ,; a - M I hereby certify that this building, as designed, is in compliance Florida Statutes. Nth the Florida -Energy Code. G'Ofj y OWNER/AGENT: BUILDING OFFICIAL: DATE: OVATE: a... - Compliance .requirefs'certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 6/19/201310:13 AM EnergyGauge® USA-.FlaRes2010 Section 405.4.1 Compliant Software Page 1_a"--__ PROJECT Title: WATERSONG - AA-KRAUS Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3317 Lot # 7 Owner: KRAUS Total Stories: 3 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: W.H. McCOMB CONSTRUCT Rotate Angle: 0 Street: LOT - 32 Permit Office: ST. LUCIE CO. Cross Ventilation: County: ST. LUCIE Jurisdiction: 661000 Whole House Fan: City, State, Zip: ST. LUCIE CO., Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 1864 19888.8808 2 Block2 1453 14530 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st 2nd Floors 1864 19888.88 No 4 2 1 Yes Yes Yes 2 3rd Floor 1453 14530 Yes 4 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 1 st 2nd Floors 88.83 ft 0 290 ft2 _-__ 1 0 0 2 Floor over Garage 1 st 2nd Floors ____ __- 1230.5 ft2 19 0.75 0 0.25 3 Raised Floor 1 st 2nd Floors ___- ___- 266.3 ft2 19 0.75 0 0.25 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1625 ft2 0 ft2 Medium 0.75 No 0.9 No 0 26.6 ATTIC in) V # Type Ventilation Vent Ratio (1 Area RBS IRCC 1 Full attic Unvented 0 1453 ft2 N N 6/19/201310:13 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 7 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (Unvente8rd Floor 20 1453 ft2 0.11 Wood 7 2 Cathedral/Single Assembly (Unverbtl2nd Floors 20 130 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 W Exterior Concrete Block - Int Insdbt 2nd Floor 14 6 2 9 4 57.6 ft2 0 0.5 0 2 S Exterior Concrete Block - Int Insdlst 2nd Floor 14 4 8 9 4 43.6 ft2 0 0.5 0 3 E Exterior Concrete Block - Int Insdbt 2nd Floor 14 5 6 9 4 51.3 ft2 0 0.5 0 4 N Exterior Concrete Block - Int Insdist 2nd Floor 14 23 9 4 214.7 ft2 0 0.01 0 5 W Exterior Concrete Block - Int Insdbt 2nd Floor 14 21 8 10 216.7 ft2 0 0.5 0 6 W Exterior Concrete Block - Int Insdbt 2nd Floor 14 6 2 10 8 65.8 ft2 0 0.5 0 7 S Exterior Concrete Block - Int lnsdbt 2nd Floor 14 17 8 10 176.7 ft2 0 0.5 0 8 S Exterior Concrete Block - Int Insdist 2nd Floor 14 49 6 10 8 528.0 ft2 0 0.5 0 9 E Exterior Concrete Block - Int Insdbt 2nd Floor 14 27 10 10 8 296.9 ft2 0 0.5 0 10 N Exterior Concrete Block - Int Insdbt 2nd Floor 14 13 2 10 131.7 ft2 0 0.01 0 11 N Exterior Concrete Block - Int lnsdbt 2nd Floor 14 54 10 8 576.0 ft2 0 0.01 0 12 W Exterior Concrete Block - Int Insul 3rd Floor • 14 7 10 70.0 ft2 0 0.5 0 13 W Exterior Concrete Block - Int Insul 3rd Floor 14 14 10 14 207.7 ft2 0 0.5 0 14 S Exterior Concrete Block - Int Insul 3rd' Floor 14 21 8 10 216.7 ft2 0 0.5 0 15 S Exterior Concrete Block - Int Insul 3rd Floor 14 39 10 14 557.7 ft2 0 0.5 0 16 E Exterior Concrete Block - Int Insul 3rd Floor 14 27 10 14 389.7 ft2 0 0.5 0 17 N Exterior Concrete Block - Int Insul 3rd Floor 14 62 6 14 875.0 ft2 0 0.01 0 18 W Exterior Frame - Wood 1st 2nd Floor 11 49 6 9 4 462.0 ft2 0.23 0.01 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood 3rd Floor None 0.460000 9 2 8 24 ft2 2 W Wood 1st 2nd Floor None 0.460000 3 2 8 8 ft2 3 W Wood 1st 2nd Floor None 0.460000 6 2 8 16 ft2 4 E Wood 3rd Floor None 0.460000 12 2 8 32 ft2 5 E Wood 1st 2nd Floor None 0.460000 5 4 2 11.1 15.60000 6 W Wood 1st 2nd Floor None 0.460000 2 8 8 21.33333 7 W Wood 1st 2nd Floor None 0.460000 3 8 0 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 12 Metal Single (Tinted) Yes 0.99 0.25 7.2 ft2 11 ft 0 in 1 ft 8 in Drapes/blinds None r 2 W 12 Metal Single (Tinted) Yes 1.01 0.25 16.0 ft2 11 ft 0 in 4 ft 4 in Drapes/blinds None 3 S 2 Metal Single (Tinted) Yes 1.09 0.25 9.2 ft2 11 ft 0 in 2 ft 8 in Drapes/blinds None 4 W 1 Metal Single (Tinted) Yes 0.99 0.25 9.3 ft2 11 ft 0 in 2 ft 0 in Drapes/blinds None 5 W 1 Metal Single (Tinted) Yes 1.01 0.25 16.0 ft2 11 ft 0 in 2 ft 8 in Drapes/blinds None 6/19/2013 10:13 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 7 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 6 W 13 Metal Single (Tinted) Yes 0.99 0.25 9.4 ft2 2 ft 0 in 3 ft 6 in Drapes/blinds None 7 W 13 Metal Single (Tinted) Yes 1.01 0.25 18.4 ft2 2 ft 0 in 5 ft 8 in Drapes/blinds None 8 W 13 Metal Single (Tinted) Yes 0.99 0.25 13.7 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 9 W 13 Metal Single (Tinted) Yes 1.01 0.25 32.012 6 ft 0 in 4 ft 2 in Drapes/blinds None 10 W 5 Metal Single (Tinted) Yes 1.09 0.25 9.2 ft2 6 ft 0 in 0 ft 8 in Drapes/blinds None 11 W 5 Metal Single (Tinted) Yes 1.01 0.25 32.0 ft2 6 ft 0 in 1 ft 0 in Drapes/blinds None 12 W 6 Metal Single (Tinted) Yes 1.09 0.25 9.2 ft2 6 ft 0 in 0 ft 8 in Drapes/blinds None 13 S 14 Metal Single (Tinted) Yes 0.99 0.25 9.4 ft2 2 ft 0 in 3 ft 6 in Drapes/blinds None 14 S 14 Metal Single (Tinted) Yes 1.09 0.25 18.4 ft2 2 ft 0 in 5 ft 9 in Drapes/blinds None 15 S 8 Metal Single (Tinted) Yes 1.09 0.25 18.4 ft2 2 ft 0 in 18 ft 2 in Drapes/blinds None 16 S 15 Metal Single (Tinted) Yes 0.99 0.25 9.4 ft2 2 ft 0 in 3 ft 6 in Drapes/blinds None 17 S 15 Metal Single (Tinted) Yes 0.99 0.25 36.8 ft2 2 ft 0 in 5 ft 9 in Drapes/blinds None 18 S 15 Metal Single (Tinted) Yes 0.99 0.25 9.4 ft2 2 ft 0 in 12 ft 2 in Drapes/blinds None 19 S 8 Metal Single (Tinted) Yes 0.99 0.25 26.0 ft2 2 ft 0 in 23 ft 6 in Drapes/blinds None 20 S 8 Metal Single (Tinted) Yes 0.99 0.25 9.4 ft2 2 ft 0 in 18 ft 2 in Drapes/blinds None 21 S 8 Metal Single (Tinted) Yes 1.09 0.25 23.2 ft2 2 ft 0 in 18 ft 2 in Drapes/blinds None 22 S 15 Metal Single (Tinted) Yes 0.99 0.25 13.4 ft2 2 ft 0 in 3 ft 6 in Drapes/blinds None 23 S 15 Metal Single (Tinted) Yes 1.09 0.25 39.1 ft2 2 ft 0 in 5 ft 9 in Drapes/blinds None 24 S 8 Metal Single (Tinted) Yes 1.09 0.25 32.4 ft2 2 ft 0 in 18 ft 2 in Drapes/blinds None 25 E 16 Metal Single (Tinted) Yes 0.99 0.25 27.4 ft2 13 ft 4 in 0 ft 8 in Drapes/blinds None 26 E 16 Metal Single (Tinted) Yes 1.01 0.25 64.0 ft2 13 ft 4 in 3 ft 8 in Drapes/blinds None 27 E 16 Metal Single (Tinted) Yes 0.99 0.25 20.0 ft2 13 ft 4 in 0 ft 8 in Drapes/blinds None 28 E 16 Metal Single (Tinted) Yes 0.99 0.25 68.6 ft2 13 ft 4 in 3 ft 0 in Drapes/blinds None 29 E 9 Metal Single (Tinted) Yes 1.01 0.25 85.3 ft2 8 ft 8 in 0 ft 8 in Drapes/blinds • None 30 E 9 Metal Single (Tinted) Yes 1.01 0.25 27.2 ft2 8 ft 8 in 1 ft 4 in Drapes/blinds None 31 N 11 Metal Single (Tinted) Yes 1.09 0.25 32.4 ft2 2 ft 0 in 18 ft 2 in Drapes/blinds None 32 N 17 Metal Single (Tinted) Yes 0.99 0.25 13.4 ft2 2 ft 0 in 3 ft 6 in Drapes/blinds None 33 N 17 Metal Single (Tinted) Yes 1.09 0.25 39.1 ft2 2 ft 0 in 5 ft 9 in Drapes/blinds None 34 N 17 Metal Single (Tinted) Yes 0.99 0.25 9.4 ft2 2 ft 0 in 3 ft 6 in Drapes/blinds None 35 N 17 Metal Single (Tinted) Yes 1.09 0.25 9.8 ft2 2 ft 0 in 5 ft 9 in Drapes/blinds None 36 N 11 Metal Single (Tinted) Yes 1.09 0.25 9.8 ft2 2 ft 0 in 18 ft 2 in Drapes/blinds None 37 N 4 Metal Single (Tinted) Yes 1.09 , 0.25 18.4 ft2 2 ft 0 in 30 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1361,016855 ft2 1 ft2 159.67 ft 9.33 ft 1 6/19/201310:13 AM EnergyGauge@) USA - FlaRes2010 Section 405.4.1 Compliant Software INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000300 2610.1 143.29 269.48 0.3044 4.5501 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None None COP: 1 34 kBtu/hr COP: 1 34 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit None None SEER: 18 42 kBtu/hr 1260 cfm 0.75 SEER: 18 35 kBtu/hr 1050 cfm 0.75 1 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane None Garage 0.59 80 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftZ DUCTS # — Supply — Location R-Value Area — Return — Air CFM25 Location Area Leakage Type Handler CIF12125 OUT QN RLF HVAC # Heat Cool 1 2 1 st 2nd Floor 6 311 ftZ 3rd Floor 6 290 ft2 1 st 2nd Floor 80 ftZ Default Leakage 1st 2nd Flo cfm (Default) 3rd Floor 75 ft2 Default Leakage 3rd Floor cfm (Default) 1 1 2 2 TEMPERATURES Programable Thermostat: Y Cooling[( j] Jan [[ ]] Feb [[ ]]Mar He [X] Jan [X] Feb [X] Mar Ventin [[ jj Jan [[ jj Feb [[X]] Mar Ceiling Fans: Apr Ma Jun X Jul X Aug Se Oct f j APr f May Jun i Jul AuI Sep Oct [X Apr [ May Jun Jul Aug Se Oct Nov Nov Nov Dec Dec Dec 6/19/2013 10:13 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 7 Schedule: HERS 2006 Reference Hours �rThermostat % Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 80 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 " Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) PM 68 68 68 68 68 68 68 68 68 68 66 66 IN 1 6/19/2013 10:13 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 7 0 FORM 405-10 Florida Code Compliance Checklist ii �- * , Florida Department of Business and Professional Regula i s` Residential Whole Building Performance Method ADDRESS: LOT - 32 PERMIT #: ST. LUCIE CO., FL, i MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 6/19/201310:13 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 7 of 7 { ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ' ESTIMATED ENERGY PERFORMANCE INDEX* = 76 The lower the EnergyPerformance Index, the more efficient the home. LOT - 32, ST. LUCIE CO., FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area ' 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior ' R=14.0 4675.40 ftz b. Frame - Wood, Exterior R=11.0 462.00 ft 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 3 d. N/A R= ftz * 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Unvented) R=20.0 1583.00 ftz 6. Conditioned floor area (ftz) 3317 b. N/A R= ftz c. N/A R= ftz 7. Windows- Description Area 11. Ducts R ftz a. U-Factor: Sgl, U=0.99 292.26 ftz a. Sup: 1 st 2nd Floors, Ret: 1 st 2nd Floors, AH: 1 st 6 311 SHGC: SHGC=0.25 b. Sup: 3rd Floor, Ret: 3rd Floor, AH: 3rd Floor 6 290 b. U-Factor: Sgl, U=1.01 290.95 ftz SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=1.09 268.42 ftz a. Central Unit 42.0 SEER:18.00 SHGC: SHGC=0.25 b. Central Unit 35.0 SEER:18.00 d. U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 6.340 ft. b. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 80 gallons a. Floor over Garage R=19.0 1230.50 ftz a. Propane EF: 0.59 b. Slab -On -Grade Edge Insulation R=0.0 290.00 ftz b. Conservation features c. other (see details) R= 266.30 ftz None �, •, •„� ..° `"'1 "` 15. Credits.1 ; ;a jj ` i �3 �� Pstat i r j . LA I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy .Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge@) USA - FlaRes2010 Section 405.4.1 Compliant Software LEGEND & ABBREVIATIONS CU. FT. DENOTES CUBIC FEET P.C.P. DENOTES PERMANENT CONTROL POINT (P) DENOTES PLAT DATA M DENOTES MEASURED DATA FND. DENOTES FOUND L.B. DENOTES LICENSED BUSINESS N.A.V.D. DENOTES NORTH AMERICAN VERTICAL DATUM C.M. DENOTES CONCRETE MONUMENT O.R.B. DENOTES OFFICIAL RECORDS BOOK IR&C DENOTES IRON ROD & CAP P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR e DENOTES ELEVATION (TYPICAL) vvv2% �* d-N DENOTES SEAGRAPE TREE N 1112633.6941 E 895695.7321 NAIL @DISK \ PCP IB 4286 FLEY-4.92' N.A.V.D. 1998 N 1112416.6816 E 895862.2747� N� Ar ti O�g$Sk $y°° z ^ �m V l` J J► 1' CONC— HEADER CURB o � O 1 \ \ dL VA � a aU PRM LB 4971 \£ IRRIGATION \ VALVE BOX —� OLD COASTAL CONSTRUCTION CONTROL LINE RECMOm OE�EER 14A 111M LOT 31 1 5/8' INC (VACANT) 4286 PKIT LB 4286 J� �ATCH BASW 2' VALLEY CURB 1 5/9' IRC 4286 p.�l TELEPHONE CATV (PEDESTAL PEDESTAL�r 0 5313`�`�"L� 3 STORY CBS RESIDENCE N 1112721.3430 E 895892.1811 4'S0 TRACT "A" J 1112471.4974 \$`'• 895982.7056 P A6 \ ?6.,y\ 41 \ >t \ \ TA Jr. u \ �' ADDRESS V>z „ FFENNCE 4804 WATERSONG WAY +ry<i APPROXIMATE `39_C MEAN HIGH WATER LINE / ELEV=0.52' NAVD 1988 LOCATED DECEMBER 23, 2011 MEAN HIGH WATER LINE WAS DETERMINED BY INTERPOLATION BETWEEN TIDE POINTS 100888 AND 100889. ATLANTIC OCEAN 0.00' ELEVATION NAVD 1988 APPROXIMATE SEASONAL HIGH WATER LINE ELEV=5.33' NAVD 198E Date ��t����U,��a 1, Co. F L lit PfOVe }i LEGAL DESCRIPTION SI—N 195999.0040 Being all of Lot 32, according to the lot of � E 895999.0040 9 9 P FND 5/6' IRC WATERSONG P.U.D. Plat No. One, as recorded in LB 4286 Plat Book 42, Page 34 of the Public Records of St._ Lucie County, Florida. GENERAL NOTES 6�w 2 GRAPHIC SCALE IN FEET METER / V" DISTANCE TO IMPROVEMENTS FURTHEST SEAWARD OF CURRENT COASTAL CONTR LINE (155.101 1) FND The bearings shown hereon are referenced to the centerline of Watersong Way having DNR CMO R-6s a bearing of N24'28'24"W, according to the plat of WATERSONG P.U.D. Plat No. One LOT 33 oo as recorded in Plat Book 42, Page 34 Public records St Lucie Count Florida. 9 1 y1 ' � � •� (OCCUPIED) 1 6959 � E / 2) All above ground fixed improvements, if any, have been located and shown hereon. 3) Underground utilities and utility services have not been located on this survey. N 1112380.2754 To E 895878.8455 4) Flood Note: By graphic plotting only, this property is in Zone "AE" (EL 6), according to the Flood Insurance Rate Map, Community Panel No. 12111C0194 J, effective date February 16, 2012. The exact designation can only be determined by an elevation 2�•p6°� �p certificate. �y L" P91 4M04WO9 \ 5) Reproductions of this map are not valid without the signature and original raised seal 2�06� of a Florida Licensed Surveyor & Mapper. s6 6) Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's deed restrictions, or Murphy Act Deeds. 7) The last date of field work was November 11, 2014. 8) Additions or deletions to survey maps or reports by other than the signing party N 1111763.4293 or parties is prohibited without written consent of the signing party or parties. E 896111.6303 9) Elevations shown hereon are in feet and are based upon North American Vertical ALONGWATER WATERSONG WAY TO A CATCH OWILL FLOW SOUTH AL Datum (N.A.V.D.) of 1988. To convert to National Geodetic Vertical Datum (N.G.V.D.) BASIN AND THENCE TO A RETENTION 1929 add 1.5 feet to the N.A.V.D. 1988 elevation. AREA BETWEEN LOTS 18 AND 19, THENCE TO STATE ROAD A-1—A THOMAS P. KIERNAN DATE Professional Surveyor & Mapper Florida Certificate No. 6199 LEGEND & ABBREVIATIONS CU. FT. DENOTES CUBIC FEET P.C.P. DENOTES PERMANENT CONTROL POINT (P) DENOTES PLAT DATA M DENOTES MEASURED DATA FND. DENOTES FOUND L.B. DENOTES LICENSED BUSINESS N.A.V.D. DENOTES NORTH AMERICAN VERTICAL DATUM C.M. DENOTES CONCRETE MONUMENT O.R.B. DENOTES OFFICIAL RECORDS BOOK IR&C DENOTES IRON ROD & CAP P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR �v� DENOTES ELEVATION (TYPICAL) ^V% DENOTES SEAGRAPE TREE 1]72721.3430 895892.1811 TRACT "A" 1112471.4974 895982.7056 \ moo\ a\ oc�\ von C EDGE OF J V£GETATQ\ >� BEACH DUNE 4' PLASTIC ` g FENCE \=h IMPROVEMENTS \WARD OF CURRENT PROPOSED GROUND FLOOR ELEV=9.0' PROPOSED GARAGE FLOOR ELEV=6.0' PROPOSED LOWEST STRUCTURAL MEMBER ELEV=17.67' N 1111763.4293 E 896111.6303 STORMWATER WILL FLOW SOUTH ALONG WATERSONG WAYoTC'A' `CATCH BASIN AND THENCE TO A RETEWTInN AREA BETWEEN LO S 18'AND 19, . THENCE TO STATE ROAD A-�-•Fi' /irr 3 i ael T. olodzi yk DcA6 Professional Surveyor & Mapper Florida Certificate No. 3864 APPROXIMATE MEAN HIGH WATER UNE ELEV=(3.52' NAVD 1988 LOCATED DECEMBER 23, 2011 MEAN HIGH WATER UNE WAS DETERMINED BY INTERPOLATION BETWEEN TIDE POINTS 100888 AND 100889. ATLANTIC OCEAN 1P 0.00' 4v \ \ r ELEVATION NAVD 1988 APPROXIMATE SEASONAL HIGH WATER LINE ELEV=5.33' NAVD 1988 LEGAL DESCRIPTION Being all of Lot 32, according to the plat of WATERSONG P.U.D. Plat No. One, as recorded in Plat Book 42, Page 34 of the Public Records of St. Lucie County, Florida. GENERAL NOTES ��—_- 2� GRAPHIC SCALE IN FEET 1) The bearings shown hereon are referenced to the centerline of Watersong Way having a bearing of N24'28'24"W, according to the plat of WATERSONG P.U.D. Plat No. One as recorded in Plat Book 42, Page 34, Public records, St Lucie County, Florida. 2) All above ground fixed improvements, if any, have been located and shown hereon. 3) Underground utilities and utility services have not been located on this survey. 4) Flood Note: By graphic plotting only, this property is in Zone "AE" (EL 6), according to the Flood Insurance Rate Map, Community Panel No. 12111CO194 J, effective date February 16, 2012. The exact designation can only be determined by an elevation certificate. 5) Reproductions of this map are not valid without the signature and original raised seal of a Florida Licensed Surveyor & Mapper. 6) Lands shown hereon were not abstracted by this office for rights —of —way, easements ,.-of record, ownership, abandonment's deed restrictions, or Murphy Act Deeds. e last date of field work was November 21, 2013. 8) Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 9) Elevations shown hereon are in feet and are based upon North American Vertical Datum (N.A.V.D.) of 1988. To convert to National Geodetic Vertical Datum (N.G.V.D.) 1929 add 1.5 feet to the_ N.A.V.D. 1988 elevation. REVISION:ADDED STEMWALL GLM 11-22-2013 REVISION: REVISED PROPOSED LOWEST STRUCTURAL MEMBER ELEV. BKH 08-15-2013 REVISION: ADDED ADJOINING BUILDING, ADDITIONAL TOPO & CONTOURS GLM 3--12-2013 REVISION: ADDED STATE PLANE COORDINATES GUM 2-28-2013 REVISION: ADDED GENERAL REVISIONS TO SITE PLAN GLM 1-29-2013 REVISION: ADDED NOTES TO SITE PLAN GUM 12-06-2012