HomeMy WebLinkAboutPhillips, Brent port gen infoINSTALLATION INSTRUCTIONS - ENGLISH Manual Transfer Interlock Kit No. LITLK IMPORTANT SAFETY INSTRUCTIONS - READ ALL INSTRUCTIONS BEFORE USING. U WARNING • TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER SUPPLYING THIS EQUIPMENT, AND CONFIRM POWER IS OFF, before installing, removing or servicing this equipment. • This equipment MUST BE installed and serviced by an electrician. • Replace all doors and covers before connecting power to this equipment. • To be installed and/or used in accordance with electrical codes and regulations. • To be used in permanently installed and listed enclosures only. TRADEMARK DISCLAIMER LEVIi6W DI-000-LITLK-05A Use herein of third party trademarks, service marks, trade names, brand names and/or product names are for informational purposes only, are/may be the trademarks of their respective owners, such use is not meant to imply affiliation, sponsorship, or endorsement. LIMITED PRODUCT WARRANTY For Leviton's limited product warranty, go to www.leviton.com. For a printed copy of the warranty you may call 1-800-323-8920. INTRODUCTION This Instruction sheet provides steps for installing the Manual Transfer Interlock Kit. The kit includes a hold down breaker bracket, generator mechanical interlock bracket along with mounting screws and a hole pattern drill template. The hold down breaker bracket is used to secure a generator supply branch breaker onto the interior assembly. The generator mechanical interlock bracket slides between the handle of the utility main breaker and the handle of generator supply breaker to prevent both from being switched ON at the same time. The hole pattern drill template will be used to drill mounting holes for the generator mechanical interlock bracket. INSTALLATION WARNING: TO AVOID FIRE, SHOCK OR DEATH: TURN OFF POWER SUPPLYING THIS EQUIPMENT, AND CONFIRM POWER IS OFF, before installing, removing or servicing this equipment. NOTE: Installation with indoor load center shown. 1. Remove the six (x6) cover screws (A) from the panelboard and lift off cover assembly (fig. 1). NOTE: Keep screws to re -attach the cover after installation. 2. Separate the dead front (B) from the cover by backing out the two (x2) captive adjustment screws (C) (fig. 2). 3. Install the hold down bracket (D) and secure to the interior base with a #10 thread cutting screw (E) (provided). Tighten to 20 in-lbf (2.2 N-m) (fig. 3). 4, Lay the dead front (B) flat with the back facing down. Place the hole pattern drill template (F) on the dead front (B) between the top of the main breaker knockout (G) and the top of the branch breaker twistouts (H) and secure in place with tape (fig. 4). Fig. 1 Fig. 2 Dead front Cover screws (B) (A) (A) ° •' 0 00 00 •oo 00 0 0 0 0 ®-' 0 Adjustment 0 screws (x2) (C) 00 00 00 00 L 0 ® ° NOTE: Installation with indoor load center shown. (> 2017 Leviton Mfg. Co., Inc. For Technical Assistance Call: 1-BOG-824-3005 (U.S.A. Only) 1 800 405-5320 (Canada Only) w Jeviton.com DI-000-LITLK-05A 5. Drill two mounting holes (1) (oO.203 in. or No. 6) for the generator mechanical interlock bracket in the dead front (B) as marked on the hole pattern drill template. OPERATION Clean any burs from other side (fig. 5). Switching from utility power to generator power (Fig. 7): 6. Secure the generator mechanical interlock bracket (J) to the dead front (B) with two #8-32 x 1/4 screws (K) (provided). Screws must from 1. Move the handle of the main breaker (L) to the OFF position. 2. Slide enter the back, through the dead front (B) and into the generator mechanical interlock bracket (J) (fig. 6). the top of the generator mechanical interlock bracket (J) down. 3. Move the handle of the generator breaker (M) to the ON position. 7. Re -attach the dead front (B) to the cover and then the cover to the panelboard. Switching from generator power to utility power (Fig 8): 1. Move the handle of the generator breaker (M) to the OFF position. SAVE THESE INSTRUCTIONS 2. Slide the top of the generator mechanical interlock bracket (J) up. 3. Move the handle of the main breaker (L) to the ON position. Fig. 3 V 0 L Fl �`—_ _'L 111_= �_�� o UD Fig. 7 ® #10 Thread --- _ cutting screw — — ®, O (E) 00 ® ® Mechanical ® B interlock Handle of main E— 0 bracket (J) breaker OFF ® in dawn (L) ® position Op Hold down — 0 18 bracket Handle of generator Fig. 4 Tap of main breaker breaON Hole pattern breaker knockout Top of branch (L) drill template (G) breaker twistouts (F' (H) Dead front Q (8) 00 Tape oc 00 Fig.5 Fig. 8 Mounting holes (00.203 in. or No. 6) (x2) (1) Dead front Handle of main breaker ON Mechanical (L) interlock bracket in up up Fig. 6 position Mechanical interlock bracket #8-32 x 1/4 Handle of W screws generator (x2)(K) breaker ((��� g�10 OFF (L' �� o 0 Dead front Q (B) o❑ 0 p 00 0 2017 Leviton Mfg. Co., Inc. For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) 1 800 405-5320 (Canada Only) www.leviton.com DI-000-LITLK-05A HOLE PATTERN DRILL TEMPLATE GABARIT DE PERQAGE PLANTILLA DE PERFORAC16N CON PATRON DE ORIFICIOS For use with catalog number LITLK / Pour le no de catalogue LITLK Para utilizarse con el catalogo nOmero LITLK Cut along dotted line / Couper le long de la ligne pointillee / Cortar a to largo de la linea punteada Mounting Holes Trous de fixation Onficros de Montag (00.203 in. or No. 6) I I I I 1 I I® ®I I I i I I I I I I I I I I I I I I I I I I I I I LEVITY DG-000-LITLK-25A For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) D 2017 Leviton Mfg. Co., Inc. 1 800 405-5320 (Canada Only) www.leviton.com DG-000-LITLK-25A