Loading...
HomeMy WebLinkAboutHowell Water Heater Permit App Miranda PL&ACAII APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date:Permit Number: Building Permit Application Planning and Development Services Building and Code Regulotion Division 2300 Virginio Avenue, Fort Pierce FL 34982 Phone: (772) 462-L553 Fax: (772\ 462-7578 Commercial Residential CBDG Funding PERM IT APPLICATION FOR: PROPOSED IMPROVEMENT Water Heater LOCATION: Address:172 NE Lobster Road Property Tax lD #: Site Plan Name: 3419-560-0014-000-7 lot No. 14 Block No. 73 Project Name:Howell Water Heater change out ke electrical water heater New Electrical Meter Second Electrical Meter (Affidavit required) CONSTRUCTION IN FORMATION : Additional work to be performed under this permit - check all that apply: _Mechanical _ Gas Tank _ Gas Piping _ Shutters _ Windows/Doors - Pond _ Generator - Roof - Pitch_ Electric - Plumbins _ Sprinklers Total Sq. Ft of Construction:Sq. Ft. of First Floor: Cost of Construction: $ 1650.00 Utilities: _ Sewer _ Septic Building Height: lf value of construction is 2500 or more, a RECORDED Notice of Commencement is required. lf value of HAVC is 57,500 or more, a RECORDED Notice of Commencement is required. DETAILED DESCRIPTION OF WORK: OWNER/LESSEE:CONTRACTOR: Name Kenrssa Howell Address:172 NE Lobster Road City:Port Saint Lucie State:FL Zip Code: 34983 Fax: Phone No. 772-801-7954 E- Mail: Fill in fee simple Title Holder on next page (if different from the Owner listed above) Name:Don Miranda Company:Miranda Plumbing & AC Address:750 NW Fnternrise Dr Srrite 100 City:State: FL Zip Code 34986 Fax: Phone No 772-878 5123 E-Mail njohns@mirandacompanies.com State or County License CFC1427227 SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable Name: Address: City:State: zip:Phone MORTGAGE COMPANY: _ Not Applicable Name: Address: City:State: zip:Phone FEE SIMPLE TITLE HOLDER: _ Not Applicable Name Add 1e:_ ress City: zip:Phone: BONDING COMPANY: _Not Applicable Name: Address: City: Zip: -- Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated, I certify that no work or installation has commenced prior to the issuance of a permit, St. Lucie Countv makes no representation that is grantinq a permit will authorize the permit holder to build the subiect structure which is in conflict with anv a'pplicable Home Owiers As5ociation rules, bvlaws or and covenants that mav restrict <ir prohibit suchstructure. Please consult with iour Home Owners Association and review'your deed for any restrictions vihich may a$ply. ln consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residentlal use ..WARNING TO OWNER: YOUR FAITURE TO RECORD A NOTICE OF COMMENCEMENT MAY NESULT ITII YOUR PAYIIUG TWICE FOR IMPROYEMENTS TO YOUR PROPERTY. A ITIOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SlrE BEFORE THE FIRST |NSPECTION. tF yOU TNTEND TO OBTATN FTNANCUUG, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE Signa}ilrE-6-f6wner/ Lessee/Contractor as Agent for Owner STATE OF FLORIDA COUNTY Qpstt-ucie The forqoing instru-'ent was 36k6elylsdgod before me this I t day cr r''-) r' i r Name of person making statement. Personally Known xxx OR Produced ldentification (Signature of Notary Public- Sta Type of ldentification actor/License Holder STATE OF FLORIDA COUNTY Qpstt-ucie The forqoing instrumo^t'^,as acknowledged before me this -l '; day of _ L ..- .. -_, 20 .l I by Don Miranda Name of person making statement. Personally Known ux OR Produced ldentification Type of ldentification Produced- *:" (Signature of Notary Public- SEA TURTLE REVIEW MANGROVE REVIEW ,, BRADFORDWHITE' WATER HEATEBS Resfde ntial Upright Electric Water Heater t t\ Photo is of RE25056 Copper Screw Type lmmersion Element (INCOLOY 'type immersion element available upon request) 6 or l|-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts. For more information on warranty, please visit www.bradfordwhite.com For products installec! in IJSA, Canada, and PuerTo Flco. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. 2,40S.271: 2.548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105i 2,107 012. Vitraglas" and Hydrojet'are registered trademarks ol BradIord White'Corporation. I The Upright Electric Models Feature: r Fully Automatic Controls-Fast acting surface-mount thermostat with high limit energy cut-off (manual reset) for safety. I Low Restrictive Brass Drain Valve-Durable tamper proof design. r Direct Heat Transfer with lmmersed Elements-Transfers heat directly and efficiently to the water. Screw-in style. Factory-lnstalled Hydrojeto Total Performance System-Sediment reducing device that also increases first hour delivery of hot water while minimizing temperature build-up in tank. Vitraglas@ Lining-An exclusively engineered enamel formula that provides superior tank protection from the highly corrosive effects of hot water. This formula (Vitraglas) is fused to the steel surface by firing at a temperature of over I600'F (871'C). lnsulation System-Non-CFC foam covers the sides and top of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity. Blanketed models additionally use a supplied flexible f iberglass insulation blanket. Water Connections- 74' (1 9mm) NPT factory-installed true dielectric fittings extend water heater life and simplify water line connections. Factory-lnstalled Heat Traps*Design incorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation. Protective Magnesium Anode Rod-Provides added protection against corrosion for long-term, trouble-free service. Simultaneous and Non-Simultaneous Operation Available- Simultaneous operation indicates when both elements (if equipped) are being heated at the same time. Non-Simultaneous operation indicates when one element is being heated at a time. Voltages Available- 1 20V, 208V, 240V, 277V, ABOV. Single Phase or Three Phase Operation Available- 1 20Y & 277V may only be wired for single phase operation. T&P Relief Valve- lnstalled. Design evaluated by ETL in accordance with Parl 280.707 (d) of HUD Mobile Home Gonstruction and Safety Standards for Energy Efficiency. I I I I I I I I (iD,.@.(} a lntertek Irtertek ,::it.;-,.., lvlodel Number Nominal 0al. Capacity U.S. lmp.Gal. Gal. DOE Rated Storage Volume (Gal,) First Hour Bating (Gal.) Unilorm Energy Factor Recovery at 90"F Risel u.s. GPH lmp, GPH A Floor to Top of llealer in. B Jacket Dia, in. c Floor to Water Confl. in. D C/L ol Water Conn, in. E Floor to T&P Conn, itt, u Water Conn. IIPI in. Approx. Shipping Weight lbs. RE33OS6 30 25 27 43 0.92 21 18 46rr/re 20 4Br5/t 8 48r5/ro 100 40 33 36 48 0,91 21 18 47 xlr 20 4911:a 8 4911n 123 RE34O56 40 33 36 49 0,s1 21 18 47 31rc 22 497/ro I 49 7/ro 114 RE34OT6 40 33 36 53 0.92 21 18 60 r/r,;20 62tla 8 6211i 125 RE35OS6 50 42 45 60 0,92 ?1 1B 47 3h;24 497/t I 497/ro 144 RE250S61 50 42 45 60 0,s2 21 18 47rln 22 49tl:t I 49tl.a 143 RE25OT6 50 42 45 64 0,92 21 t8 59 20 00 r/4 I 60'a 130 Besidential Electric Water Heater Upright Models C.E.C. Listed f Models include supplied insulation blanket (2 thick). Dimensions in charts above do not include blanket thickness. For 10 year models, change suffix "6" to "10".- Based on 4500W4500W, Non-Simultaneous operation. Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings. (GPH based on N o n- S im ultaneous operation, when Simultaneous operation the GPH will approximately double.) General: Meets NAECA Requirements All models ETL listed. These heaters are wired inter-locking (Non-Simultaneous, Single Phase) 240V with two 4500W elements, unless otherwise specified. All waterand electrical connections are3/4" (1 9mm) NPT. All models cerlified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1 034 kPa.). Dimensions and specifications sub/'ect to change without notice in accordance with our policy of continuous product improvement. _ BRADFORD WHITE IS - AME RICAN STRONG Sales; 800-523-2931 t Fax 21 5-641 -1 61 2 24/7 Technical Supportr 800-334-3393 ) Email techserv@bradfordwhite.com Built to be the Best' Model Number Nominal Liter Capacity DOE Rated Storage Volume (Liters) First Hour Rating {Liters) Uniform Energy tactor Becovery at 50"C Bise- Liters/ Hour A Floor to Top of Heater ntm. B Jacket 0ia. mm. c Floor to Water Conn. mn. D C/L of t{later Conn. mm. E Floor to T&P Conn. mm. G Water Conn. NPT mm. Approx. Shipping Weight 114 102 163 0,92 79 1186 508 1?43 203 1243 t9 45 151 36 182 0,91 79 199 508 1256 203 1 256 19 56 RE34OS6 t5l 36 186 0,91 79 t99 559 1256 203 1256 19 52 RE34OI6 151 36 201 0,92 79 529 508 1586 203 1586 io 57 RE35OS6 189 70 227 0.92 79 100 610 1256 203 1256 lo 65 RE25t)S6 189 170 227 no,79 oo 559 I 256 203 1256 19 65 BE25OT6 18S 110 242 0.92 79 499 508 1 530 203 1 530 19 59 yes yes yes yes n0 yes yes yes n0 2500w / 3000w / 3500w / 4000w i 5000w / t-8"- | {zolmm)I o.- p+@+q Recovery A LPH Temperature Rise 'C 34 45 50 56 67 10 8 7 6 5 38 30 26 23 19 14 10 I 8 7 53 38 34 30 26 17 13 11 10 I 64 49 42 38 34 79 57 53 45 38 24 18 16 14 12 91 68 61 53 45 28 21 18 16 14 106 79 68 61 53 31 23 21 19 15 117 87 79 72 57 41 31 28 25 1 55 1 17 '106 95 79 1 201 -F,0621 (02021, Bradford White Corporation, USA, All rights reserved.Printed in U.S.A. Anode RE25OT6 Only n o Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved. Property ldentification Property taxes are subject to change upon change of ownership. . Past taxes are not a reliable projection offuture taxes.. The sale of a property wiII prompt the removal of all exemptions, assessment caps, and special classifications. Site Address: 172 LOBSTER RD Sec/Town/Range : 28/36Si408 Parcel ID : 34 1 9-560-00 14-000-7 Julisdiction: Saint Lucie County Ownership Jamar Howell Kenissa Howell 172 NE Lobster RD Port St Lucie, FL 34983- 1 7 1 8 Legal Description RIVER PARK-UNIT 9-PART'A' BLK 73 LOT 2s 87) Current Values Just/\4alket Value: Assessed Value: Exemptions: Taxable Value: 14 (MAP 34l28N) (OR 3764- $ r 39,400 $87,80 l $s0,000 $37,80 1 Use Type: 0100 Account #:43332 Map ID: 34l28N Zoning'. RS-4 Count TotalAreas Finished/Under Air (SF): Gross Sketched Area (SF): Land Size (acres): Land Size (SF): 1,408 3,144 0.19 8.3 60 Taxes for this parcel: SLC Tax Collector's Office E Download TRIM fol this palcel: Download PDF El I II III. 140 160 160 &rv AII inforn-ration is believed to be oorrect at this time, but is subject @ Copyright 2021 Saint Lucie Courty Property to change and is provided without any warranty. Appraiser. Al1 rights reserved. Building Design Wind Speed Occupancy Category Speed Sources/[inks: