HomeMy WebLinkAboutHowell Water Heater Permit App Miranda PL&ACAII APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date:Permit Number:
Building Permit Application
Planning and Development Services
Building and Code Regulotion Division
2300 Virginio Avenue, Fort Pierce FL 34982
Phone: (772) 462-L553 Fax: (772\ 462-7578
Commercial Residential
CBDG Funding
PERM IT APPLICATION FOR:
PROPOSED IMPROVEMENT
Water Heater
LOCATION:
Address:172 NE Lobster Road
Property Tax lD #:
Site Plan Name:
3419-560-0014-000-7 lot No. 14
Block No. 73
Project Name:Howell Water Heater
change out ke electrical water heater
New Electrical Meter Second Electrical Meter (Affidavit required)
CONSTRUCTION IN FORMATION :
Additional work to be performed under this permit - check all that apply:
_Mechanical _ Gas Tank _ Gas Piping _ Shutters _ Windows/Doors
-
Pond
_ Generator
-
Roof
-
Pitch_ Electric - Plumbins _ Sprinklers
Total Sq. Ft of Construction:Sq. Ft. of First Floor:
Cost of Construction: $ 1650.00 Utilities: _ Sewer _ Septic Building Height:
lf value of construction is 2500 or more, a RECORDED Notice of Commencement is required.
lf value of HAVC is 57,500 or more, a RECORDED Notice of Commencement is required.
DETAILED DESCRIPTION OF WORK:
OWNER/LESSEE:CONTRACTOR:
Name Kenrssa Howell
Address:172 NE Lobster Road
City:Port Saint Lucie State:FL
Zip Code: 34983 Fax:
Phone No. 772-801-7954 E-
Mail:
Fill in fee simple Title Holder on next page (if different
from the Owner listed above)
Name:Don Miranda
Company:Miranda Plumbing & AC
Address:750 NW Fnternrise Dr Srrite 100
City:State: FL
Zip Code 34986 Fax:
Phone No 772-878 5123
E-Mail njohns@mirandacompanies.com
State or County License CFC1427227
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: _ Not Applicable
Name:
Address:
City:State:
zip:Phone
MORTGAGE COMPANY: _ Not Applicable
Name:
Address:
City:State:
zip:Phone
FEE SIMPLE TITLE HOLDER: _ Not Applicable
Name
Add
1e:_
ress
City:
zip:Phone:
BONDING COMPANY: _Not Applicable
Name:
Address:
City:
Zip:
--
Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated,
I certify that no work or installation has commenced prior to the issuance of a permit,
St. Lucie Countv makes no representation that is grantinq a permit will authorize the permit holder to build the subiect structure
which is in conflict with anv a'pplicable Home Owiers As5ociation rules, bvlaws or and covenants that mav restrict <ir prohibit suchstructure. Please consult with iour Home Owners Association and review'your deed for any restrictions vihich may a$ply.
ln consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residentlal use
..WARNING TO OWNER: YOUR FAITURE TO RECORD A NOTICE OF COMMENCEMENT MAY NESULT ITII YOUR PAYIIUG
TWICE FOR IMPROYEMENTS TO YOUR PROPERTY. A ITIOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SlrE BEFORE THE FIRST |NSPECTION. tF yOU TNTEND TO OBTATN FTNANCUUG, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE
Signa}ilrE-6-f6wner/ Lessee/Contractor as Agent for Owner
STATE OF FLORIDA
COUNTY Qpstt-ucie
The forqoing instru-'ent was 36k6elylsdgod before me
this I t day cr r''-) r' i r
Name of person making statement.
Personally Known xxx OR Produced ldentification
(Signature of Notary Public- Sta
Type of ldentification
actor/License Holder
STATE OF FLORIDA
COUNTY Qpstt-ucie
The forqoing instrumo^t'^,as acknowledged before me
this -l '; day of _ L ..- ..
-_, 20 .l I by
Don Miranda
Name of person making statement.
Personally Known ux OR Produced ldentification
Type of ldentification
Produced-
*:"
(Signature of Notary Public-
SEA TURTLE
REVIEW
MANGROVE
REVIEW
,,
BRADFORDWHITE'
WATER HEATEBS
Resfde ntial Upright
Electric Water Heater
t
t\
Photo is of
RE25056
Copper Screw Type lmmersion Element
(INCOLOY 'type immersion element available upon request)
6 or l|-Year Limited Tank Warranties / 6 or 10-Year Limited Warranty on Component Parts.
For more information on warranty, please visit www.bradfordwhite.com
For products installec! in IJSA, Canada, and PuerTo Flco. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
2,40S.271: 2.548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105i 2,107 012. Vitraglas" and Hydrojet'are registered trademarks ol BradIord White'Corporation.
I
The Upright Electric Models Feature:
r Fully Automatic Controls-Fast acting surface-mount thermostat with high
limit energy cut-off (manual reset) for safety.
I Low Restrictive Brass Drain Valve-Durable tamper proof design.
r Direct Heat Transfer with lmmersed Elements-Transfers heat directly
and efficiently to the water. Screw-in style.
Factory-lnstalled Hydrojeto Total Performance System-Sediment
reducing device that also increases first hour delivery of hot water while
minimizing temperature build-up in tank.
Vitraglas@ Lining-An exclusively engineered enamel formula that provides
superior tank protection from the highly corrosive effects of hot water. This
formula (Vitraglas) is fused to the steel surface by firing at a temperature of
over I600'F (871'C).
lnsulation System-Non-CFC foam covers the sides and top of the tank,
reducing heat loss. This results in less energy consumption, improved
efficiencies, and jacket rigidity. Blanketed models additionally use a supplied
flexible f iberglass insulation blanket.
Water Connections- 74' (1 9mm) NPT factory-installed true dielectric
fittings extend water heater life and simplify water line connections.
Factory-lnstalled Heat Traps*Design incorporates a flexible disk that
reduces heat loss in piping and eliminates the potential for noise generation.
Protective Magnesium Anode Rod-Provides added protection against
corrosion for long-term, trouble-free service.
Simultaneous and Non-Simultaneous Operation Available-
Simultaneous operation indicates when both elements (if equipped) are being
heated at the same time. Non-Simultaneous operation indicates when one
element is being heated at a time.
Voltages Available- 1 20V, 208V, 240V, 277V, ABOV.
Single Phase or Three Phase Operation Available- 1 20Y & 277V may
only be wired for single phase operation.
T&P Relief Valve- lnstalled.
Design evaluated by ETL in accordance with Parl 280.707 (d) of HUD
Mobile Home Gonstruction and Safety Standards for Energy Efficiency.
I
I
I
I
I
I
I
I
(iD,.@.(}
a
lntertek Irtertek ,::it.;-,..,
lvlodel
Number
Nominal
0al.
Capacity
U.S. lmp.Gal. Gal.
DOE
Rated
Storage
Volume
(Gal,)
First
Hour
Bating
(Gal.)
Unilorm
Energy
Factor
Recovery at
90"F Risel
u.s.
GPH
lmp,
GPH
A
Floor to
Top of
llealer
in.
B
Jacket
Dia,
in.
c
Floor to
Water
Confl.
in.
D
C/L ol
Water
Conn,
in.
E
Floor to
T&P
Conn,
itt,
u
Water
Conn.
IIPI
in.
Approx.
Shipping
Weight
lbs.
RE33OS6 30 25 27 43 0.92 21 18 46rr/re 20 4Br5/t 8 48r5/ro 100
40 33 36 48 0,91 21 18 47 xlr 20 4911:a 8 4911n 123
RE34O56 40 33 36 49 0,s1 21 18 47 31rc 22 497/ro I 49 7/ro 114
RE34OT6 40 33 36 53 0.92 21 18 60 r/r,;20 62tla 8 6211i 125
RE35OS6 50 42 45 60 0,92 ?1 1B 47 3h;24 497/t I 497/ro 144
RE250S61 50 42 45 60 0,s2 21 18 47rln 22 49tl:t I 49tl.a 143
RE25OT6 50 42 45 64 0,92 21 t8 59 20 00 r/4 I 60'a 130
Besidential Electric Water Heater
Upright Models C.E.C. Listed
f Models include supplied insulation blanket (2 thick). Dimensions in charts above do not include blanket thickness.
For 10 year models, change suffix "6" to "10".- Based on 4500W4500W, Non-Simultaneous operation.
Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
(GPH based on
N o n- S im ultaneous
operation, when
Simultaneous
operation the GPH
will approximately
double.)
General:
Meets NAECA Requirements
All models ETL listed. These heaters are wired inter-locking (Non-Simultaneous, Single Phase) 240V with two 4500W elements, unless
otherwise specified. All waterand electrical connections are3/4" (1 9mm) NPT. All models cerlified at 300 PSI test pressure (2068 kPa) and
150 PSI working pressure (1 034 kPa.).
Dimensions and specifications sub/'ect to change without notice in accordance with our policy of continuous product improvement.
_ BRADFORD WHITE IS -
AME RICAN
STRONG Sales; 800-523-2931 t Fax 21 5-641 -1 61 2
24/7 Technical Supportr 800-334-3393 ) Email techserv@bradfordwhite.com
Built to be the Best'
Model
Number
Nominal
Liter
Capacity
DOE
Rated
Storage
Volume
(Liters)
First
Hour
Rating
{Liters)
Uniform
Energy
tactor
Becovery at
50"C Bise-
Liters/
Hour
A
Floor to
Top of
Heater
ntm.
B
Jacket
0ia.
mm.
c
Floor to
Water
Conn.
mn.
D
C/L of
t{later
Conn.
mm.
E
Floor to
T&P
Conn.
mm.
G
Water
Conn.
NPT
mm.
Approx.
Shipping
Weight
114 102 163 0,92 79 1186 508 1?43 203 1243 t9 45
151 36 182 0,91 79 199 508 1256 203 1 256 19 56
RE34OS6 t5l 36 186 0,91 79 t99 559 1256 203 1256 19 52
RE34OI6 151 36 201 0,92 79 529 508 1586 203 1586 io 57
RE35OS6 189 70 227 0.92 79 100 610 1256 203 1256 lo 65
RE25t)S6 189 170 227 no,79 oo 559 I 256 203 1256 19 65
BE25OT6 18S 110 242 0.92 79 499 508 1 530 203 1 530 19 59
yes
yes
yes
yes
n0
yes
yes
yes
n0
2500w /
3000w /
3500w /
4000w i
5000w /
t-8"-
| {zolmm)I o.-
p+@+q
Recovery A
LPH Temperature Rise 'C
34 45 50 56 67
10 8 7 6 5 38 30 26 23 19
14 10 I 8 7 53 38 34 30 26
17 13 11 10 I 64 49 42 38 34
79 57 53 45 38
24 18 16 14 12 91 68 61 53 45
28 21 18 16 14 106 79 68 61 53
31 23 21 19 15 117 87 79 72 57
41 31 28 25 1 55 1 17 '106 95 79
1 201 -F,0621 (02021, Bradford White Corporation, USA, All rights reserved.Printed in U.S.A.
Anode
RE25OT6
Only
n
o
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved.
Property ldentification
Property taxes are subject to change upon
change of ownership.
. Past taxes are not a reliable projection offuture taxes.. The sale of a property wiII prompt the removal of all
exemptions, assessment caps, and special classifications.
Site Address: 172 LOBSTER RD
Sec/Town/Range : 28/36Si408
Parcel ID : 34 1 9-560-00 14-000-7
Julisdiction: Saint Lucie County
Ownership
Jamar Howell
Kenissa Howell
172 NE Lobster RD
Port St Lucie, FL 34983- 1 7 1 8
Legal Description
RIVER PARK-UNIT 9-PART'A' BLK 73 LOT
2s 87)
Current Values
Just/\4alket Value:
Assessed Value:
Exemptions:
Taxable Value:
14 (MAP 34l28N) (OR 3764-
$ r 39,400
$87,80 l
$s0,000
$37,80 1
Use Type: 0100
Account #:43332
Map ID: 34l28N
Zoning'. RS-4 Count
TotalAreas
Finished/Under Air (SF):
Gross Sketched Area (SF):
Land Size (acres):
Land Size (SF):
1,408
3,144
0.19
8.3 60
Taxes for this parcel: SLC Tax Collector's Office E
Download TRIM fol this palcel: Download PDF El
I II III.
140 160 160
&rv
AII inforn-ration is believed to be oorrect at this time, but is subject
@ Copyright 2021 Saint Lucie Courty Property
to change and is provided without any warranty.
Appraiser. Al1 rights reserved.
Building Design Wind
Speed
Occupancy Category
Speed
Sources/[inks: