HomeMy WebLinkAboutAPPROVED Denshield ULGeorgia-Pacific
DensShield®
Tile Backer
Manufacturer
Georgia-Pacific Gypsum
133 Peachtree Street
Atlanta, GA 30303
Technical Service Hotline: 1-800-225-6119
Description
DensShield® Tile Backer is a substrate that, when properly installed,
provides significant water and moisture resistance— making it excellent
for protecting both tile installations and stud cavities. DensShield Tile Backer
is composed of a water-resistant treated core that is covered front and back
with fiberglass mats. On the the side, DensShield Tile Backer's built-in coating
on the surface stops surface water and retards moisture transmission, protecting
the wall cavity.
Unlike cementitious backer boards, DensShield Tile Backer has a built-in
moisture barrier. DensShield Tile Backer is 12 Ibs (5.4 kg) to 32 Ibs (15 kg)
lighter per 4' x B' (1220 mm x 2438 mm) panel, depending on manufacturer,
than cement board, which makes installation easier. DensShield Tile Backer
provides excellent dimensional stability and strength so it can be installed
parallel or at right angles to framing in wall and ceiling applications.
DensShield Tile Backer, with its fiberglass mat design, has been tested
by a third party, as manufactured, in accordance with ASTM D3273 and
has scored the highest achievable rating (10 out of 10) for mold resistance.
DensShield Tile Backer has UL Environmental claim validation for mold
resistance (UL 2824). DensShield Tile Backer has been shown to be excellent
for tile and non -tile installations in wet and non -wet applications, in areas
of high humidity, and in appropriate fire -rated wall assemblies. It is ideal
for interior walls, ceilings, residential and light commercial floors and
countertop applications in high moisture areas such as baths, showers,
kitchens, laundries, swimming pool areas and locker rooms.
The score of 10, in the ASTM D3273 test, indicates no mold growth in a
4-week controlled laboratory test. The mold resistance of any building
product when used in actual job site conditions may not produce the same
results as were achieved in the controlled, laboratory setting. No material
can be considered mold proof. When properly used with good design,
handling and construction practices, Dens® Brand gypsum products provide
increased mold resistance compared to standard paper -faced wallboard. For
more information, go to www.buildgp.com/safetyinfo.
Primary Uses
DensShield Tile Backer provides an excellent backer for sidewalls and ceilings
in bathtub and shower installations, where it provides an even, solid substrate
for tile. DensShield Tile Backer may also be finished with paint or wallpaper
for non -tile areas that require superior fire and moisture resistance where
its moisture barrier and water -repelling qualities are desirable.
Submittal Job Name
Approvals
Contractor
Date
Technical Service Hotline 1.80OM5.6119 or
www.densshield.com
1/4" (6.4 mm) and 1/2" (12.7 mm) x 4' (1220 mm) wide DensShield Tile Backer
can be used as a substrate in floor tile applications for residential and light
commercial use as defined in the Handbook for Ceramic Tile Installation
published by the Tile Council of North America.
Limitations
Tiles should be applied on the grey coated side of DensShield Tile Backer.
DensShield Tile Backer should not be used in commercial saunas, steam
rooms, around fireplaces or areas where prolonged exposure to heat exceeds
125° F (52° Q.
DensShield Tile Backer panels should not be used as a shower pan base or
in shower floors and curbs.
DensShield Tile Backer should not be used for exterior installations.
DensShield Tile Backer panels should not be used as a base for nailing and
mechanical fastening.
DensShield Tile Backer should not be used in conjunction with passive solar
heat systems.
For floors, use floor grade tile, 2" x 2" (51 mm x 51 mm) or larger.
Use framing or furring when applying over concrete or masonry block.
Adhesives alone should not be used to install DensShield Tile Backer.
In floor applications, adhesives and fasteners must be used. In wall
applications, fasteners must be used.
Since DensShield Tile Backer has a built-in moisture barrier; never install
vapor retarders directly behind DensShield Tile Backer panels. In retrofit
applications, some paints or other wall coverings may constitute a vapor
barrier; remove or effectively penetrate these coverings prior to installing
DensShield Tile Backer panels.
Technical Data
When tested in conformance with ASTM E96, DensShield Tile Backer panels
achieved a perm rating of less than 1.5 142.9 ng/Pa •s • m2) alone, 1.0 (28.6)
with dry set mortars.
In a test by a third party testing laboratory, DensShield Tile Backer was
subjected to a shower of water at 110°F (43.3*Q 12 minutes per hour,
24 hours a day, 7 days a week for six months. The installation had no grout
between the tiles. No deterioration occurred to either the DensShield Tile
Backer board, the framing members or the wall cavity.
5/8" (15.9 mm) DensShield® Fireguard® Tile Backer is UL and ULC classified
as Type DS and included in numerous assembly designs listed by UL and ULC for
hourly fire resistance ratings.
5/8" (15.9 mm) DensShield Fireguard Tile Backer is classified as "Type V
in accordance with ASTM C1178 and may replace Type X gypsum board
specified in generic rated wall assemblies listed in the Gypsum Association
Fire Reference and Sound Control Design Manual, Publication GA-600.
continued-0-
A GeorglaVaclfic
DensShield®
Tile Backer
DensShield® Tile Backer has passed the Robinson Floor Test/ASTM C627
in both 1/4" (6.4 mm) and 1/2" x 4' (12.7 mm x 1220 mm) wide thicknesses
with a rating of residential and light commercial.
Handling and Use —CAUTION
WARNING: Provide appropriate exhaust ventilation at places where dust is
formed. Minimize dust generation and accumulation. Do not breathe dust.
Do not get this material in contact with eyes. Do not taste or swallow. Avoid
prolonged exposure. Observe good industrial hygiene practices. Use only in
well -ventilated areas. Wear appropriate NIOSH/MSHA approved dust mask
or filtering facepiece if dust is generated. Do not eat or drink while using the
product. Wash hands before eating, drinking, or smoking.
Safety Data Sheet (SDS) is available at www.buildgp.com/safetyinfo.
A,4�k Georgia-Pacific
Gypsum
U.S.A. GP Gypsum LLC
Canada Georgia-Pacific Canada LP
SALES INFORMATION AND ORDER
PLACEMENT
U.S.A. Northeast:
1-8"7.4497
Southeast:
1.800-327-2344
Pacific Southwest:
1-800-924-7503
Pacific Northwest:
14100.4444XI92
Midwest:
14100.876-4746
Central:
14100-M-100
CANADA Eastern Canada:
14100-387-M
Western Canada:
14W-5584092
DENSDECK
1 4155-647-M
TECHNICAL INFORMATION
U.S.A. and Canada: 14 00-225-6119, www.gpgypsum.com
Technical Service Hotline 1.800.225.6119 or
www.densshield.com
Sizes and Edges
Thickness
Width x Length
1/4"16.4 mm)
4' x 4' (1220 mm x 1220 mm)
112" 112.7 mm)
32"x 5' (813 mm x 1524 mm)
4'x 5'(1220 mm x 1524 mm)
4'x8'(1220mmx2438mm)
5/8" (15.9 mm)
4' x 8' (1220 mm x 2438 mm)
Edges: Square
Manufactured to meet ASTM C1178 Fiberglass Mat Water -Resistant Gypsum
Backing Panel
TRADEMARKS DENSSHIELD, FIREGUARD and the GEORGIA-PACIFIC logo are trademarks owned
by or licensed to GP Gypsum LLC and Georgia-Pacific Canada LP.
WARRANTIES, REMEDIES AND TERMS OF SALE For current warranty intonnation for this
product, please go to www.gpgypsum.com and select the product for warranty information. All sales
of this product by Georgia-Pacific are subject to our Terms of Sale available at www.gpgypstim.corn.
UPDATES AND CURRENT INFORMATION The information in this document may change without
notice. Visit our website at www.gpgypsum.com for updates and current information.
CAUTION For product fire, safety and use information, go to www.buildgp.com/safetyinlo
or call 1-600-225-6119.
FIRE SAFETY CAUTION Passing a fire test in a controlled laboratory setting and/or certifying or
labeling a product as having a one -hour, two-hour, or any other fire resistance or protection rating
and, therefore, as acceptable for use in certain fire rated assemblies/systems. does not mean that
either a particular assembly/system incorporating the product, or any given piece of the product
itself, will necessarily provide one -hour fire resistance, two-hour fire resistance, or any other
specified fire resistance or protection in an actual fire. In the avant of an actual fire, you should
immediately take any and all actions necessary for your safety and the safety of others without
regard for any fire tatfng of any product or assembly/system.
02020 GP Gypsum LLC. All ri hb Rwnw;.12/20. GP -TM Lit. Item /67M.