Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Load Short Form 6/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Farinas Residence, Air Conditioning UnlimitedFor: TBD Easy St, Fort Pierce, FL 34982 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S301A AHRI ref Coil ASPT37C14A AHRI ref 201785798 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.2 Sensible cooling Btuh19600 Heating output Btuh24650 Latent cooling Btuh8400 Temperature rise °F24 Total cooling Btuh28000 Actual air flow cfm933 Actual air flow cfm933 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.054 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.72 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Master Bath 100 2244 730 91 39 Laundry 68 969 854 40 46 M Hall 26 0 0 0 0 Master Bed 247 2544 2773 104 148 WIC 66 1697 525 69 28 FoyerGR 351 4213 3617 172 194 Pantry 14 0 0 0 0 KitchenNook 270 3472 4575 142 245 Bed 3 173 3060 1893 125 101 Bath 54 651 215 27 12 Lin 8 0 0 0 0 Bed 2 184 4038 2247 165 120 Hall 30 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 2 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N House 1589 22888 17428 933 933 Other equip loads 2475 1314 Equip. @ 0.95 RSM 17881 Latent cooling 7264 TOTALS 1589 25363 25145 933 933 2021-Jun-09 12:21:03 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Building Analysis 6/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Farinas Residence, Air Conditioning UnlimitedFor: TBD Easy St, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 19.048293.1Walls 12.7322818.1Glazing 0.71773.7Doors 6.215751.0Ceilings 21.454213.43.4Floors 11.930171.9Infiltration 18.34641Ducts 00Piping 00Humidification 9.82475Ventilation0Adjustments 100.025363Total Cooling Walls Glazing OtherCeilingsInfiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 16.030081.9Walls 21.7407422.8Glazing 1.01793.7Doors 5.29670.6Ceilings 000Floors 4.58430.5Infiltration 17.83338Ducts 7.01314Ventilation 26.85020Internal gains 00Blower 0Adjustments 100.018743Total Latent Cooling Load = 7264 Btuh Overall U-value = 0.106 Btuh/ft²-°F Data entries checked. 2021-Jun-09 12:21:03 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Component Constructions 6/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Farinas Residence, Air Conditioning UnlimitedFor: TBD Easy St, Fort Pierce, FL 34982 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd inI, 8" Thk, 1/2" Gyp Bd Int Fnsh 9963.155.10.109316n 6372.02 5242.028203.155.10.109260e 6232.029753.155.10.109309s 9412.0214713.155.10.109467w 27262.0242613.155.10.1091352all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 2821.465682.9411.00.101193 Windows Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.17 ft window ht, 1 ft sep.); 8 ft head ht 62027.241018.000.62023e Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 6 ft overhang (5.17 ft window ht, 1 ft sep.); 8 ft head ht 76816.882118.000.62046e Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (3.17 ft window ht, 1 ft sep.); 8 ft head ht 9213.511516.800.5807s Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 8 ft head ht 87828.152516.800.58031w Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 10 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht 53711.290518.800.65048w 36315.145218.800.65024w 90112.5135718.800.65072all Doors Fbrgls Door 1793.731773.697.00.12748e 2021-Jun-09 12:21:03 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 2 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N Ceilings Attic, Metal Roof, R-30 Ceil Ins, 1/2" Gyp Bd Int Fnsh 0.0341589 9670.6115750.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00542128.700.989189 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Project Summary 6/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Farinas Residence, Air Conditioning UnlimitedFor:TBD Easy St, Fort Pierce, FL 34982 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh18247 Structure Btuh14090 Ducts Btuh4641 Ducts Btuh3338Central vent (78 cfm) 2475 Btuh Central vent (78 cfm) Btuh1314 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh25363 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh17881 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2725 Ducts Btuh1538Central vent (78 cfm) Btuh3001 CoolingHeating Outside air15891589Area (ft²) Equipment latent load Btuh7264 1494614946Volume (ft³)Air changes/hour 0.200.38 Equipment Total Load (Sen+Lat)Btuh25145 Equiv. AVF (cfm) 5095 Req. total capacity at 0.70 SHR ton2.1 Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg.Trade Trade GOODMAN Model Cond GSX16S301AAHRI ref Coil ASPT37C14A AHRI ref 201785798Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW7.2 Sensible cooling Btuh19600Heating output Btuh24650 Latent cooling Btuh8400 Temperature rise °F24 Total cooling Btuh28000Actual air flow cfm933 Actual air flow cfm933 Air flow factor cfm/Btuh0.041 Air flow factor cfm/Btuh0.054Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.72 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Right-J® Worksheet 6/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name House Master Bath 2 Exposed wall 189.0 ft 22.5 ft 3 Room height 9.4 ft 9.3 heat/coolft 4 Room dimensions ft12.5x8.0 5 Room area 1588.8 ft²100.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 316 316 996 637 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 377 260 820 524 23 23 73 47 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 27.1827.18 23 0 410 620 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 16.8316.83 46 35 821 768 0 0 0 0 11 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 48 48 177 179 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 316 309 975 623 116 109 345 220 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 7 7 115 92 7 7 115 92 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 570 467 1471 941 19 19 59 37 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 31 0 525 878 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 11.2011.20 48 44 905 537 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 15.1415.14 24 22 452 363 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 193 193 568 282 51 51 150 75 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 1589 1589 1575 967 100 100 99 61 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 1589 189 5421 0 100 23 645 0 6 c) AED excursion 815 -27 Envelope loss/gain 15230 8227 1487 506 12 a) Infiltration 3017 843 302 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 0 0 Appliances/other 4100 0 Subtotal (lines 6 to 13)18247 14090 1789 591 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 18247 14090 1789 591 15 Duct loads 25%24%4641 3338 25%24%455 140 Total room load 22888 17428 2244 730 Air required (cfm)Air required (cfm)933 933 91 39 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03Right-Suite® Universal 2021 21.0.07 RSU29066 Page 2...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Right-J® Worksheet 6/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Laundry M Hall 2 Exposed wall 10.5 ft 4.0 ft 3 Room height 10.0 heat/coolft 9.3 heat/coolft 4 Room dimensions ft6.5x10.5 ft6.5x4.0 5 Room area 68.3 ft²26.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 27.1827.18 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 16.8316.83 0 0 0 0 0 0 0 0 11 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 11.2011.20 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 15.1415.14 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 105 105 308 153 37 37 109 54 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 68 68 68 42 26 26 26 16 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 68 11 301 0 26 4 115 0 6 c) AED excursion -30 -3 Envelope loss/gain 677 165 250 67 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)677 665 250 67 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 96 26 -250 -67 14 Subtotal 773 690 0 0 15 Duct loads 25%24%197 164 25%24%0 0 Total room load 969 854 0 0 Air required (cfm)Air required (cfm)40 46 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03Right-Suite® Universal 2021 21.0.07 RSU29066 Page 3...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Right-J® Worksheet 6/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Bed WIC 2 Exposed wall 14.5 ft 17.0 ft 3 Room height 9.8 heat/coolft 9.3 heat/coolft 4 Room dimensions ft17.0x14.5 ft11.0x6.0 5 Room area 246.5 ft²66.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 27.1827.18 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 16.8316.83 0 0 0 0 0 0 0 0 11 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 102 102 322 206 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 142 103 323 207 56 56 176 112 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 16 0 262 439 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 11.2011.20 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 15.1415.14 24 22 452 363 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 247 247 244 150 66 66 65 40 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 247 15 416 0 66 17 488 0 6 c) AED excursion 491 -19 Envelope loss/gain 1698 1650 1051 340 12 a) Infiltration 272 76 302 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)1969 2226 1353 424 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 59 16 0 0 14 Subtotal 2028 2242 1353 424 15 Duct loads 25%24%516 531 25%24%344 100 Total room load 2544 2773 1697 525 Air required (cfm)Air required (cfm)104 148 69 28 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03Right-Suite® Universal 2021 21.0.07 RSU29066 Page 4...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Right-J® Worksheet 6/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name FoyerGR Pantry 2 Exposed wall 29.0 ft 0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft351.0x1.0 ft3.0x4.5 5 Room area 351.0 ft²13.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 237 144 452 289 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 27.1827.18 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 16.8316.83 46 35 821 768 0 0 0 0 11 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 48 48 177 179 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 33 33 103 66 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 11.2011.20 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 15.1415.14 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 351 351 348 214 14 14 13 8 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 351 29 832 0 14 0 0 0 6 c) AED excursion -130 0 Envelope loss/gain 2732 1385 13 8 12 a) Infiltration 515 144 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)3247 2889 13 8 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 111 35 -13 -8 14 Subtotal 3359 2924 0 0 15 Duct loads 25%24%854 693 25%24%0 0 Total room load 4213 3617 0 0 Air required (cfm)Air required (cfm)172 194 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03Right-Suite® Universal 2021 21.0.07 RSU29066 Page 5...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Right-J® Worksheet 6/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name KitchenNook Bed 3 2 Exposed wall 23.0 ft 27.0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft270.0x1.0 ft172.5x1.0 5 Room area 270.0 ft²172.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 112 112 352 225 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 27.1827.18 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 16.8316.83 0 0 0 0 0 0 0 0 11 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 214 166 523 334 140 124 390 250 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 16 0 262 439 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 11.2011.20 48 44 905 537 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 15.1415.14 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 270 270 268 164 173 173 171 105 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 270 23 660 0 173 27 774 0 6 c) AED excursion 386 122 Envelope loss/gain 2355 1422 1950 1141 12 a) Infiltration 409 114 480 134 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 1700 250 Subtotal (lines 6 to 13)2764 3696 2430 1525 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 4 3 10 6 14 Subtotal 2768 3699 2439 1530 15 Duct loads 25%24%704 876 25%24%620 363 Total room load 3472 4575 3060 1893 Air required (cfm)Air required (cfm)142 245 125 101 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03Right-Suite® Universal 2021 21.0.07 RSU29066 Page 6...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Right-J® Worksheet 6/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bath Lin 2 Exposed wall 6.0 ft 0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft6.0x9.0 ft2.5x3.0 5 Room area 54.0 ft²7.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 56 56 176 112 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 27.1827.18 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 16.8316.83 0 0 0 0 0 0 0 0 11 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 11.2011.20 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 15.1415.14 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 54 54 54 33 8 8 7 5 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 54 6 172 0 8 0 0 0 6 c) AED excursion -8 0 Envelope loss/gain 401 138 7 4 12 a) Infiltration 107 30 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)508 168 7 4 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 11 6 -7 -4 14 Subtotal 519 174 0 0 15 Duct loads 25%24%132 41 25%24%0 0 Total room load 651 215 0 0 Air required (cfm)Air required (cfm)27 12 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-09 12:21:03Right-Suite® Universal 2021 21.0.07 RSU29066 Page 7...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Right-J® Worksheet 6/9/2021Date:House Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Bed 2 Hall 2 Exposed wall 35.5 ft 0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft183.8x1.0 ft8.5x3.5 5 Room area 183.8 ft²29.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 149 149 469 300 0 0 0 0 .WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 116 93 294 188 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 27.1827.18 23 0 410 620 0 0 0 0 .GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 16.8316.83 0 0 0 0 0 0 0 0 11 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 65 65 205 131 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ss 16.8216.82 13.4813.48 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 11.2011.20 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 15.1415.14 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Metal Roof, R 0.034Attic, Metal Roof, R 0.034 --0.990.99 0.610.61 184 184 182 112 30 30 29 18 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 184 36 1018 0 30 0 0 0 6 c) AED excursion 34 -1 Envelope loss/gain 2579 1385 29 17 12 a) Infiltration 631 176 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 250 0 Subtotal (lines 6 to 13)3210 1811 29 17 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 10 6 -29 -17 14 Subtotal 3219 1817 0 0 15 Duct loads 25%24%819 430 25%24%0 0 Total room load 4038 2247 0 0 Air required (cfm)Air required (cfm)165 120 0 0 2021-Jun-09 12:21:04 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Duct System Summary 6/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Farinas Residence, Air Conditioning UnlimitedFor: TBD Easy St, Fort Pierce, FL 34982 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.568 / 0.132 in H2O in H2O0.568 / 0.132 Lowest friction rate in/100ft0.306in/100ft0.306 Actual air flow cfm933cfm933 Total effective length (TEL) ft229 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3130.047.0VlFx0x04.00.3211432651hBath st3130.055.8VlFx0x07.00.3061441984038hBed 2 st3130.052.2VlFx0x07.00.3121221503060hBed 3 st3130.047.6VlFx0x06.00.3201161031808cFoyerGR st1110.035.8VlFx0x06.00.3891161031808cFoyerGR-A st1110.037.0VlFx0x06.00.386147852287cKitchenNook st1110.037.1VlFx0x06.00.386147852287cKitchenNook-A 80.07.5VlFx0x04.00.6495547854cLaundry st2105.025.4VlFx0x06.00.435471102244hMaster Bath st2105.022.3VlFx0x05.00.44689621386cMaster Bed st2105.021.0VlFx0x05.00.45189621386cMaster Bed-A st2105.022.0VlFx0x05.00.44734831697hWIC Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 482 396 0.306 884 10.0 0x0 VinlFlx st1 st1 Peak AVF 755 806 0.306 754 14.0 0x0 VinlFlx st2 Peak AVF 317 259 0.435 718 9.0 0x0 VinlFlx 2021-Jun-09 12:21:04 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 2 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb4 0x 2070 212 43.3 0.306 479 9.0 x0 0 VlFx rb8 0x 5650 642 0 0 0 0 x0 0 VlFx rb2 0x 1980 144 0 0 0 0 x0 0 VlFx rb3 0x 1500 122 0 0 0 0 x0 0 VlFx 2021-Jun-09 12:21:04 Right-Suite® Universal 2021 21.0.07 RSU29066 Page 1 ...e\Documents\Wrightsoft HVAC\TBD Easy St PSL.rup Calc = MJ8 Front Door faces: N 1524Job:Manual S Compliance Report 6/9/2021Date:House Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Farinas Residence, Air Conditioning UnlimitedFor: TBD Easy St, Fort Pierce, FL 34982 Cooling Equipment Design Conditions °F76.7Entering coil DB:Btuh18743Sensible gain:°F90.4Outdoor design DB: °F64.4Entering coil WB:Btuh7264Latent gain:°F77.4Outdoor design WB: Btuh26007Total gain:°F75.0Indoor design DB: cfm933Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: GSX16S301A+ASPT37C14AModel:Goodman Mfg.Manufacturer: cfm933Actual airflow: % of load107Btuh20141Sensible capacity: % of load102Btuh7435Latent capacity: %73SHR:% of load106Btuh27576Total capacity: Heating Equipment Design Conditions °F67.0Entering coil DB:Btuh25363Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm933Actual airflow: °F50Temp. rise:% of load97kW7.2Output capacity: Meets all requirements of ACCA Manual S.