Loading...
HomeMy WebLinkAbout6 Julia esealCOPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC. PROJECT ADDRESS:DRAWN BYDATE DRAWNREVISION12SHEET NO:34PROFESSIONAL ENGINEER THOMAS P. ARNETT, P.E. LICENSE No. #46043 FLORIDA ALUMINUM ENGINEERING, INC. L I CENSET H OMASP.ARNETTPROFESSIONALENGIN E ERFLORIDA This item has beenelectronically signed and sealedby T.P. Arnett, PE. using aDigital Signature with date andtime. Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified onany electronic copies.5601 MARINER STREET SUITE 240 TAMPA FL. 33609 TEL: (813) 374-2403 FAX: (813) 374-4516 FLORIDA BUSINESS REGISTRY LICENSE NO. 32807 CONTRACTOR: Master Craft Aluminum ProductsDESIGN CRITERIA:Applicable Codes, Regulations, and Standards1.The 7th Edition (2020) Florida Building Code, specifically Chapter16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood.2.AA ASM 35 and AA ADM1 Specifications for AluminumStructures, Part 1-A of the Aluminum Design Manual prepared byThe Aluminum Association. and the AAF Guide to AluminumConstruction in High Wind Areas.3.ASCE 7-16.Loading Criteria1.Live Load: 10 PSF per 7th Edition (2020) Florida Building Code,Appendix I Section 105.12.Dead Load: 1 PSF3.Wind Load:3.1.Building Occupancy Category, Section 1604.5 and Table1604.5: Risk Category 1.3.2.Ultimate Design Wind Speed: VULT = 150 MPH, NominalDesign Wind Speed: VASD = 116 MPH3.3.Exposure Category, Section 1609.4.3: Exposure C3.4.Screen Enclosure Section 2002.44.Building Category for Aluminum Structures, Section 2002.6:Category Type 1 - Patio Cover: Non-Habitable, UnconditionedRoof Type1.Roof Type: MONOSLOPE2.Roof Material: 3” x 48” x 0.024” composite panel Elite 2000, 1.0#density foam, Florida Product Approval Number FL 7561-R5.Foundation DesignExisting concrete. No additional concrete footing or slab is requiredto resist the loads imposed upon the existing slab by the proposedconstruction if the existing slab is a minimum of 4” thick and insound condition, free from structural cracking, spalling, or otherdeterioration.SpecificationsThe following specifications are applicable to this project:1.All work shall be in accordance with the 7th Edition (2020) FloridaBuilding Code, and any other applicable local codes and regulations.2.Aluminum extrusions shall be 6005 T5 Alloy. Due to quality controlissues, no manufacturer substitution is acceptable without the specificwritten, signed and sealed authorization of Florida AluminumEngineering, Inc.3.Fasteners are required to be corrosion resistant, minimum SAE Grade2 or better zinc plated to ASTM B633, or coated stainless steel series"300", or uncoated stainless steel series "400".4.Approved concrete screw anchors to be Simpson Titen-HD orequivalent.5.All Self Mating Beam Sections are to be stitched with either #14screws 6” from ends and 24” center to center or #12 screws 6" fromends and 12" center to center.6.Where concrete specifications are required, whether in the screenenclosure scope or not, by one or more regulatory agency, thefollowing specifications are applicable:a.Concrete shall conform to ASTM C94 for the followingcomponents:i.Portland Cement Type 1,- ASTM C 150ii.Aggregates - Large Aggregate 3/4” max - ASTM C 33iii.Air entraining +/- 1% - ASTM C 260iv.Water reducing agent - ASTM C 494v.Clean Potable watervi.Other admixtures not permittedb.Metal accessories shall conform to:i.Reinforcing Bars - ASTM A615, grade 60ii.Welded wire fabric - ASTM A185c.Concrete slump at discharge chute not less than 3” or morethan 5”. Water added after batching is not permitted.d.Prepare and place concrete per American Concrete InstituteManual of Standard Practice, Parts 1, 2, and 3 including hotweather recommendations.e.Moist cure or polyethylene curing permitted.f.Prior to placing concrete, treat the entire subsurface area fortermites in compliance with the FBC.g.Concrete shall be placed over a polyethylene vapor barrier.h.All aluminum components embedded within concrete shall becoated with a bituminous paint or epoxy.7.All flashing and weatherproofing shall be provided by the contractor.8.Use of these plans acknowledges and accepts a limit of liability not toexceed design and engineering fee.WIND SPEED AND EXPOSURE HAVEBEEN DETERMINED USING THE ADVANCEDTECHNOLOGY COUNCIL'S WEBSITEAND GOOGLE EARTH.A-1DUCKY RECOVERY 6 JULIA PORT ST LUCIE FL 34951TP----09/10/21 2" x 2" x 3" x 1/8" ALUM ANGLEEACH SIDE OF UPRIGHTW/ (1) 3/8" DIA. x 3" CONCRETEANCHORS (2 1/4" EMBEDMENT)INTO CONCRETE & (2) 3/8" DIA. x 4"THRU BOLTS THROUGH POST3" x 3" POST TO DECK CONNECTION DETAILSSCALE: NTS3" x 3" x 0.125"POSTBA-2COMPOSITE ROOF TO POST CONNECTIONSCALE: NTS(5) 1/4" x 4" LAGS W/1 1/4" DIA. NEOPRENEFACED WASHER PER PANEL3" COMPOSITEROOF PANEL(4) 3/8" DIA.THRU BOLTS2" x 6" SMB3" x 3" x 0.125"POST3" x 0.062" ALUMRECEIVING CHANNELW/ #10 x 3/4" TOP ANDBOTTOM AS END CAPSA-2EXISTINGHOSTS-1A-2COMP. ROOF TO CORNER POST @ 4TH WALL DETAILSCALE: NTSFLASHING3" x 3" x 0.125"POST2" x 6" SMB(5) 1/4" x 4" LAGS W/1 1/4" DIA. NEOPRENEFACED WASHER PER PANEL3" COMPOSITEROOF PANEL(4) 3/8" DIA.THRU BOLTNOTE:HEADER ATTACHMENT TOFASCIA W/ 1/4" LAGS @ 24" O.C.W/ 1 3/4" EMBEDMENT2" x 3" x 0.050"KNEE BRACEUPRIGHT1 1/2" x 2 1/8" x 1 1/2" x0.062" x 3" LONG ALUMRECEIVING CHANNEL W/ (3)#12 x 3/4" SMS EA. FACE &(3) #12 x 3/4" INTO POST3" COMP ROOF PANELKNEE BRACE CONNECTION DETAILSCALE: NTSSELF-MATING BEAM12"12"S-2A-21 1/2" x 2 1/8" x 1 1/2" x0.062" x 3" LONG ALUMRECEIVING CHANNEL W/ (3)#12 x 3/4" SMS EA. FACE &(3) #12 x 3/4" INTO BEAMCOPYRIGHTCNOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF FLORIDA ALUMINUM ENGINEERING, INC. PROJECT ADDRESS:DRAWN BYDATE DRAWNREVISION12SHEET NO:34PROFESSIONAL ENGINEER THOMAS P. ARNETT, P.E. LICENSE No. #46043 FLORIDA ALUMINUM ENGINEERING, INC. 5601 MARINER STREET SUITE 240 TAMPA FL. 33609 TEL: (813) 374-2403 FAX: (813) 374-4516 FLORIDA BUSINESS REGISTRY LICENSE NO. 32807 ALUMINUM MEMBERS DIMENSIONSHOLLOW SECTIONS2 x 2: 2” x 2” x 0.046”2 x 3: 2” x 3” x 0.050”2 x 4: 2” x 4” x 0.050”2 x 5: 2” x 5” x 0.050”OPEN BACK SECTIONS1 x 2: 1” x 2” x 0.040”1 x 3: 1” x 3” x 0.045” SNAP SECTIONS2 x 2 Snap: 2” x 2” x 0.045”2 x 3 Snap: 2” x 3” x 0.050”2 x 4 Snap: 2” x 4” x 0.045”SELF MATING (SMB)2 x 4 SMB: 2” x 4” x 0.044” x 0.100”2 x 5 SMB: 2” x 5” x 0.050” x 0.100”2 x 6 SMB: 2” x 6” x 0.050” x 0.120”2 x 7 SMB: 2” x 7” x 0.057” x 0.120”2 x 8 SMB: 2” x 8” x 0.072” x 0.124”2 x 9 SMB: 2” x 9” x 0.072” x 0.124”2 x 10 SMB: 2” x 10” x 0.092” x 0.398”MINIMUM FASTENER EDGE DISTANCE: 1/2"MINIMUM FASTENER SPACING: 3/4"CONCRETE SCREW ANCHOR:SIMPSON TITEN HD OR EQUIVALENTSHEET METAL SCREWS (SMS):ITW / BUILDEX OR EQUIVALENTA-2-DUCKY RECOVERY 6 JULIA PORT ST LUCIE FL 34951TP09/10/21---