Loading...
HomeMy WebLinkAboutProduct Approval Underlayments4/19/2021 Florida Building Code Online ail ilz; t 5 i tt tE 4 td,tir �£r acts Home. ; Log In ( User Registrauon Hol. Topics ' Submit surcharge j stats & Facts P,iwicallons j Contact Us' DCIS life trap I Links i Search p '110 1fi(l'i t x+r „ i ucr?)klgav_'�r M'� ri > PrnriUet dr Ag.lt > I.i)_P i Application Detall Product Approval USVA: Public User e•� .r= , FL # FL3AS39 4 Application Type New Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing. and Asphalt LLC Address/Phone/Email 1 Owens Corning Parkway ioiedo, Oil 43657 (740) 587-3562 . greg,ke6ler@owenscorning.com Authorized Signature Greg Keeler g reg.keeler@owenscorn ing, com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory . Underlayments .Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality. Assurance Entity PRi Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2024: Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FI 34539 Rt) COI OCR20001 2020 FBC Eval TJ2i-8tlZLT Grarluiar,pdf Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2015. ASTM D 226 2009 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method .' Method 1 Option D blips+//floridahuilding.orglprlpr app_dtl.aspx?param=wGEVXQwtDqtDQIYvhxNFJgGNYW2SIyjWsijWc%2fsUEu7iOvDVs7lRvA%3d%3d 1/2 4/19/2021 Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products r --� lorida Building Code Online 10/14/2020 10/15/2020 10/25/2020 12/16/2020 FL # 34539.1 Model, Number or Na TRI-BUILT Granular Un rne _- erlayment Description A self -adhered under layment used as an alternative to ASTM D 226, Type 11 roofing felt. Limits of Use Installation Instructions Approved for use In HVHZI No 1704539 RO II OCR20001 2020 FBC Eval TRI-BUILT Granular pd Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressures N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL34539 RO AE OCR20001 2020 FBC Eval TRI-BUILT GranularRd l Created by Independent Third Party: Yes Contact Us :: 2601 al The State of Florida Is an AA/EEO employer. Copyright 21 Under Florida law, email addresses are public records. If you do mail to this entity. Instead, contact the office by phone or by trad Florida Statutes, effective October 1, 2012, licensees licensed un provided may be used for official communication with the Ucensi provide the Department with an email address which can be mad i i B++ck I1..•sst - t Ir Stang Road, Tallahassee FL 32349 Phone: 850-487-1824 D7_2013 State of Florida.:: Privacy Statement ;: Accessibility, Statement :: Refund Statement iot want your e•mall address released In response to a public -records request, do not send electronic Zonal mail. If you have any questions, please contact 650.497.1395. *Pursuant to Section 455.275(1), er Chapter 455, F.S. must provide the Department with an email address If they have one. The emails However email addresses are public record. 'it you do not wish to supply a personal address, please ! available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here _. Product Approval Acceptst 0 W 99 Mm Credit Card . Safe EcomlivalLmiaNm 212 CR ' EEK. TECHN, ]CAL SERVICES.. LLC EVALUATION REPORT Manufacturer: Manufacturing Location: Quallty Assurance: SCOPE Certificate -of Authorization No, 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 480-3421, FLORIDA BUILDING CODE, 7"' EDITION (2020) BEACON SALES ACQUISITIONS, INC. c/a OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Corning Parkway, . Toledo, OH 43657 (800) 438-7465 www:owenscorning;com Houston, TX Brentwood, NH PRI Construction Materials Technologies, LLC (QUA9110) Category: Roofing Subcategory: Underlayments Code Sections: 1607.1.1, 1607.1.1.1 Properties: Physical properties REFERENCES Issued October 14, 2020 Entity Report No, Starlderd Year PRI Construction Materials Technologies (fST6040) OCF-294-02-01 ICC-ES AC 188 2012 ICC-ES AC 48 2012 PRI Construction Materials Technologies (TST6049) OCF-338-02-01 ASTM D 1970 2015a 'Determined to be equivalent to ASTM D 226-09, Type it PRODUCT DESCRIPTION TRI-BUILT Granular A self -adhered underlayment used. as an alternative to ASTM D 226, Type II roofing felt. Underlayment The' underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. See manufacturer's installation instructions for further detail. OCR20001 This evaluation report is provided for State of Florida produc Technical Services„LLC of any product,changes or quality 6 This evaluation report does not express nor imply warranty, specifically addressed herein. 1 of 3 changes throughout the duration for which this report is valid. n, recommended use, or other product attributes that are not CREEK TEci1NICAL. SERVICES, LL..0 1 BEACbkSALES ACQUISITIONS," INC. . c/o OWENS CORNING ROOFING AND ASPHALT LLC Tt2l-BUILT. Granular Underlayinent Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction Deck shall be installed, in accordance with FBC requirements. Roof c ecks shall have no more.than 1/8" yap at abutting joints. Min. slope: 2:12 or in accordancE in. with FBC Application: Prior to beginning in tallation, the underlayment shall'be.unrolled and allowed to relax for a minimum of 3-5 minutes: The underlayment installation shall comply with FBC Table 1507 1.1.1: The underlayment shall be installed with the roll length paraliel'to the eave, starting at the eave fold the underlayment away from eave onto itself, The underlayment shall be installed di ect to -decking with the lower i6lease backer removed and. pressed firmly Into pace to ensure complete contact,'with the deck. Repeat with upper release backer. Overlap successive courses with minimum 3" side laps and minimum 6" slaggiareo end laps. ; In steep -slope applications (>6:12); it is permissible`io nail the underlayment 12- inches on -center as needed (nails shall be installed perpendicular to deck with the nail )leads flush to th Jop surface of the underlayment}. For valley applications, the roll shall be applied centered along the valley prior .to installing the underlayment at the eave and overlapped a minimum of 6-inches, For eave protection, he underlayment should extend 'to a point 18-inches beyond the interior wall. , Min. Application Temperature: 40°F; Contact the ma ufacturer when installing at tI emperatures below the minimum application temperature. r Allowable roof coverings: Mechanical attachment of asphalt shingles and slate, shingles shall be permitted in accordance with the F130: 2of3 This evaluation report is provided for State of Florida product approval under Rule`61G20-3. The manufacturer shall notify c;Rl Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v This evaluation report does not express norimply warranty; installation, recommended .use, or other product attributes that are specifically addressed herein. �i rBEACON SALES ACQUISITIONS, INC. CREEK ' r c/o OWENS CORNING ROOFING AND ASPHALT LLC TECI-INIC_AL,SERVICrs, LI_C TRI-BUILT Granular Underlayment LIMIT 1) This evaluation report is not for use in the HVHZ, 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report; the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) The underlayment may be used as described in other current FBC product approval documents. 1) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be. mechanically fastened through the underlayment to the roof deck. 0) The underlayment shall notbe installed over existing roof coverings. 9) The underlayment shall be installed starling at the eave in horizontal layers such that the laps shed water from the deck, The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a minimum of 24-inches from the preceding course. 10) The underlayment shall be exposedon the roof deck for a. maximum duration of 30 days. 11) All products listed in this report shall be manufactured Linder a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as.evidenced in the referenced documents submitted by, the named manufacturer. ,tl}i[1[it11J \- � • No 74021 :1 STATE OF t w� C? e e`% CERTIFICATION OF INDEPENDENCE 2020.10.14 15:45:22 04100' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any cornpany manufacturing or distributing products under this evaluation. Zachary, R. P iest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. OCR20001 END OF REPORT FL34539 3of3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,,or other product attributes [hat are not specifically addressed herein.