HomeMy WebLinkAboutProduct Approval Underlayments4/19/2021 Florida Building Code Online
ail ilz; t 5 i tt tE 4 td,tir �£r
acts Home. ; Log In ( User Registrauon Hol. Topics ' Submit surcharge j stats & Facts P,iwicallons j Contact Us' DCIS life trap I Links i Search
p '110
1fi(l'i t
x+r „
i ucr?)klgav_'�r M'� ri > PrnriUet dr Ag.lt > I.i)_P i Application Detall
Product Approval
USVA: Public User
e•� .r= ,
FL #
FL3AS39
4
Application Type
New
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing. and Asphalt LLC
Address/Phone/Email 1 Owens Corning Parkway
ioiedo, Oil 43657
(740) 587-3562 .
greg,ke6ler@owenscorning.com
Authorized Signature Greg Keeler
g reg.keeler@owenscorn ing, com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory . Underlayments
.Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality. Assurance Entity PRi Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 12/31/2024:
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FI 34539 Rt) COI OCR20001 2020 FBC Eval TJ2i-8tlZLT Grarluiar,pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D 1970 2015.
ASTM D 226 2009
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method .' Method 1 Option D
blips+//floridahuilding.orglprlpr app_dtl.aspx?param=wGEVXQwtDqtDQIYvhxNFJgGNYW2SIyjWsijWc%2fsUEu7iOvDVs7lRvA%3d%3d 1/2
4/19/2021
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
r --�
lorida Building Code Online
10/14/2020
10/15/2020
10/25/2020
12/16/2020
FL #
34539.1
Model, Number or Na
TRI-BUILT Granular Un
rne _-
erlayment
Description
A self -adhered under layment used as an alternative to ASTM D
226, Type 11 roofing felt.
Limits of Use
Installation Instructions
Approved for use In HVHZI No
1704539 RO II OCR20001 2020 FBC Eval TRI-BUILT
Granular pd
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressures N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
FL34539 RO AE OCR20001 2020 FBC Eval TRI-BUILT
GranularRd l
Created by Independent Third Party: Yes
Contact Us :: 2601 al
The State of Florida Is an AA/EEO employer. Copyright 21
Under Florida law, email addresses are public records. If you do
mail to this entity. Instead, contact the office by phone or by trad
Florida Statutes, effective October 1, 2012, licensees licensed un
provided may be used for official communication with the Ucensi
provide the Department with an email address which can be mad
i
i
B++ck I1..•sst - t
Ir Stang Road, Tallahassee FL 32349 Phone: 850-487-1824
D7_2013 State of Florida.:: Privacy Statement ;: Accessibility, Statement :: Refund Statement
iot want your e•mall address released In response to a public -records request, do not send electronic
Zonal mail. If you have any questions, please contact 650.497.1395. *Pursuant to Section 455.275(1),
er Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
However email addresses are public record. 'it you do not wish to supply a personal address, please
! available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here _.
Product Approval Acceptst
0 W 99 Mm
Credit Card
. Safe
EcomlivalLmiaNm
212
CR ' EEK.
TECHN, ]CAL SERVICES.. LLC
EVALUATION REPORT
Manufacturer:
Manufacturing Location:
Quallty Assurance:
SCOPE
Certificate -of Authorization No, 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421,
FLORIDA BUILDING CODE, 7"' EDITION (2020)
BEACON SALES ACQUISITIONS, INC.
c/a OWENS CORNING ROOFING AND ASPHALT
LLC
1 Owens Corning Parkway,
.
Toledo, OH 43657
(800) 438-7465
www:owenscorning;com
Houston, TX
Brentwood, NH
PRI Construction Materials Technologies, LLC (QUA9110)
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1607.1.1, 1607.1.1.1
Properties:
Physical properties
REFERENCES
Issued October 14, 2020
Entity Report No,
Starlderd
Year
PRI Construction Materials Technologies (fST6040) OCF-294-02-01
ICC-ES AC 188
2012
ICC-ES AC 48
2012
PRI Construction Materials Technologies (TST6049) OCF-338-02-01
ASTM D 1970
2015a
'Determined to be equivalent to ASTM D 226-09, Type it
PRODUCT DESCRIPTION
TRI-BUILT Granular A self -adhered underlayment used. as an alternative to ASTM D 226, Type II roofing felt.
Underlayment The' underlayment is composed of SBS modified asphalt with a fiberglass mat internal
reinforcement and is surfaced with granules. The product is supplied with a nominal
thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. See
manufacturer's installation instructions for further detail.
OCR20001
This evaluation report is provided for State of Florida produc
Technical Services„LLC of any product,changes or quality 6
This evaluation report does not express nor imply warranty,
specifically addressed herein.
1 of 3
changes throughout the duration for which this report is valid.
n, recommended use, or other product attributes that are not
CREEK
TEci1NICAL. SERVICES, LL..0
1
BEACbkSALES ACQUISITIONS," INC. .
c/o OWENS CORNING ROOFING AND ASPHALT LLC
Tt2l-BUILT. Granular Underlayinent
Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or
existing construction Deck shall be installed, in accordance with FBC
requirements. Roof c ecks shall have no more.than 1/8" yap at abutting joints.
Min. slope: 2:12 or in accordancE in. with FBC
Application: Prior to beginning in tallation, the underlayment shall'be.unrolled and allowed to
relax for a minimum of 3-5 minutes: The underlayment installation shall comply
with FBC Table 1507 1.1.1:
The underlayment shall be installed with the roll length paraliel'to the eave, starting
at the eave fold the underlayment away from eave onto itself, The underlayment
shall be installed di ect to -decking with the lower i6lease backer removed and.
pressed firmly Into pace to ensure complete contact,'with the deck. Repeat with
upper release backer. Overlap successive courses with minimum 3" side laps and
minimum 6" slaggiareo end laps. ;
In steep -slope applications (>6:12); it is permissible`io nail the underlayment 12-
inches on -center as needed (nails shall be installed perpendicular to deck with the
nail )leads flush to th Jop surface of the underlayment}.
For valley applications, the roll shall be applied centered along the valley prior .to
installing the underlayment at the eave and overlapped a minimum of 6-inches,
For eave protection, he underlayment should extend 'to a point 18-inches beyond
the interior wall.
,
Min. Application Temperature: 40°F; Contact the ma ufacturer when installing at tI emperatures below the
minimum application temperature.
r
Allowable roof coverings: Mechanical attachment of asphalt shingles and slate, shingles shall be permitted in
accordance with the F130:
2of3
This evaluation report is provided for State of Florida product approval under Rule`61G20-3. The manufacturer shall notify c;Rl
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v
This evaluation report does not express norimply warranty; installation, recommended .use, or other product attributes that are
specifically addressed herein.
�i
rBEACON SALES ACQUISITIONS, INC.
CREEK
' r c/o OWENS CORNING ROOFING AND ASPHALT LLC
TECI-INIC_AL,SERVICrs, LI_C TRI-BUILT Granular Underlayment
LIMIT
1) This evaluation report is not for use in the HVHZ,
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report; the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) The underlayment may be used as described in other current FBC product approval documents.
1) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be. mechanically
fastened through the underlayment to the roof deck.
0) The underlayment shall notbe installed over existing roof coverings.
9) The underlayment shall be installed starling at the eave in horizontal layers such that the laps shed water
from the deck, The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a
minimum of 24-inches from the preceding course.
10) The underlayment shall be exposedon the roof deck for a. maximum duration of 30 days.
11) All products listed in this report shall be manufactured Linder a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020) as.evidenced in the referenced documents submitted by, the named manufacturer.
,tl}i[1[it11J
\- � •
No 74021
:1 STATE OF t w�
C? e
e`%
CERTIFICATION OF INDEPENDENCE
2020.10.14
15:45:22
04100'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any cornpany manufacturing or distributing products under this evaluation.
Zachary, R. P iest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
OCR20001
END OF REPORT
FL34539
3of3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,,or other product attributes [hat are not
specifically addressed herein.