Loading...
HomeMy WebLinkAboutENERGY CALCS & MANUAL J - 9 INDIGO(1) FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street THE STERLING Permit Office: ST. LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Locatiom FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2} 1. New construction or existing New(From Plans) 10. Wall Type�1442.0 sgft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insui,Exterior R=4.1 1250.00 ftz b.Frame-Wood,Adjacent R=11.0 192.00 ftz 3. Number of units,if multiple family i c.NIA R= ftz 4. Number of Bedrooms 2 d.NIA R= ftz 5. Is this a worst case? Yes 11•Ceiling Types (1504.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1474.00 ftz 6. Conditioned floor area above grade(ftz) 1474 b.Knee Wall(Vented) R=19.0 30.00 ftz Conditioned floor area below grade(ftz) 0 c.NIA R= ftz 7. Windows(141.3 sgft.) Description Area 12.Ducts R ftz a. U-Factor: Sgl,U=1.04 101.25 ftz a.Sup:Attic,Ret:Attic,AH:Attic 6 125 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ftz 13.Cooling systems k8tulhr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ftz SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14.Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.284 a.Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ftz 15. Hot water systems SHGC(AVG): NIA a.Electric Cap:50 gallons 9. Floor Types (1473.5 sgft.) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1473.50 ftz b. Conservation features b. NIA R= ftZ None c.NIA R= ftz 16.Credits None Glass/Floor Area: 0.096 Total Proposed Modified Loads: 44.66 PASS Total Baseline Loads: 45.56 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this = p Code. calculation indicates compliance with the Florida Energy Code. rrrny: 'C•� ,;.?� t3 PREPARED BY:QV40 Before construction is completed W DATE 022 this building will be inspected for {}1 compliance with Section 553.908 g hereby certify that this building, as designed,isj'n compliance Florida Statutes. , with the Florida Energy Code. OWNER/A T: BUILDING OFFICIAL: DATE. �' DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). Ill 3/20218:02 AM EnergyGauge®USA 7.0.00-RaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot# Owner Name: Total Stories: 1 Block(Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE STERLING Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL New[Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil 10 Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 329 ft- ---- 0 1 0 2 Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft' -__ 0 1 0 3 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft' -_ 0 1 0 4 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 W 0 1 0 5 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft2 -- 0 1 0 6 Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' 0 1 0 7 Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ---- 0 1 0 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC An Edition(2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8SIab-On-Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 0 1 0 9 SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft' _ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Bart Absor. Tested Tested Insui. (deg) 1 Gable or Shed Metal 1553 ft' 246 ft' Light N 0.6 No 0.9 No 0 18.4 / ATTIC v # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic(Vented) M.BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic(Vented) KITCHEN 30 Blown 192 ft2 .1 Wood 5 Under Attic(Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic(Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREATIDINING 30 Blown 488 ft- 0.1 Wood 10 Knee Wall(Vented) BEDROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block-Int InsiBEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 2 SW=>NE Exterior Concrete Block-Int InsuBEDROOM 4.1 28 0 8 0 224.0 W 0 0 0A 0 3 NW=>SE Exterior Concrete Block-Int InsuBEDR00M 4.1 14 0 8 0 112.0 ft' 0 0 0.4 0 4 SW=>NE Exterior Concrete Block-Int Insul M.BATH 4.1 8 0 8 0 64.0 W 0 0 0.4 0 5 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Block-Int InsBEDR00M 2 4.1 16 0 8 0 128.0 it- 0 0 0.4 0 7 SE=>NW Exterior Concrete Block-Int InsENEDROOM 2 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 8 S=>N Exterior Concrete Block-Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 _9 SW=>NE Exterior Concrete Block-Int InSBEDROOM 2 4.1 2 0 8 0 16.0 ft- 0 0 0.4 0 10 SE=>NW Exterior Concrete Block-Int Insul ENTRY 4.1 6 0 8 0 48.0 ft- 0 0 0.4 0 11 SW=>NE Exterior Concrete Block-Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 _12 SW=>NE Exterior Concrete Block-Int InsULALINDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 _13 NE=>SW Exterior Concrete Block-Int lns0REAT/DINI 4.1 26 0 8 0 208.0 ft- 0 0 0.4 0 _14 NW=>SE Exterior Concrete Block-Int Ins8REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/132021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame-Wood KITCHEN 11 24 8 192.0 W 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal .Low-E Single Yes 1.04 0.29 N 32.9 ft- 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 SW=>NE 4 Metal Low-E Single Yes 1.04 0.29 N 6.9 W 1 ft 0 in 1 ft 5 in None None 3 SE=>NW 7 Metal Low-E Single Yes 1.04 0.29 N 24.0 ft2 6 ft 0 in 1 ft 5 in None None 4 NE=>SW 13 Metal Low-E Single Yes 1.04 0.29 N 37.5 ft' i ft 0 in 1 It 5 in None None 5 NW=>SE14 Metal low-E Single Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.48 141.7 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing[ HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15 34.8 kBtulhr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Carl # Company Name System Model# Collector Model# Area Volume FEF None None fF DUCTS / —Supply-- —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 125 ft- Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre T)hermosta[[t:]]N [[�j Ceiling Fans: �0 rXI D0 pr('� Cooling eat ng l J Jan [)n Feb lxJ Mar Apr € May J May un [ ]Jul [ ] Nov Dee Aug [ ]Sep L J Oct [ ]X Nov Dec Venting I 1 Jan II 11 Feb ll�Xll Mar Jun I I Jul [ 1 Aug I 1 Sep txl Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(V'/D) PM 78 78 78 78 78 78 78 78 78 78 78 78 8 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft- ft 0.3 WIC Defauk(8 lts/sq.ft. ft- ft 0.3 M.BATH Default(8 lbs/sq.fL ft- ft 0.3 KITCHEN Default(811s/sq.R ft- It 0.3 BATH Default(81bs/sq.ft. ft- ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft- ft 0.3 LAUNDRY Default(8 lbs/s .ft. ft? ft 0.3 GREAT/DINING Ill 3/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 5 of 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w x Design Location: FL,Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic Y dropped 9 The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dro ed ceiling/soffit /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barter. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the Cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned Spec as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind nininn an winnn Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index,the more efficient the home. THE STERLING, FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1250.00 ft2 b.Frame-Wood,Adjacent R=11.0 192.00 ft2 3. Number of units,if multiple family 1 c WA R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case. Yes 11.Ceiling Type and insulation level Insulation Area a.Under Attic(Vented) R=30.0 1474.00 ft 6. Conditioned floor area(ft2) 1474 b.Knee Wall(Vented) R=19.0 30.00 ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor. S91,U=1.04 101.25 f1 12-Ducts,location&insulation level R ft2 SHGC: SHGC=0.29 a.Sup:Attic,Ret:Attic,AH:Attic 6 125 b. U-Factor. Sgl,U=1.11 40.00 ft2 SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor. WA ft2 a.Central Unit 34.8 SEER:15.00 SHGC: d. N/A SHGC:: 14.Heating systems kBtu/hr Efficiency SHGC: Area Weighted Average Overhang Depth: 3.832 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15.Hot water systems a. U-Factor(AVG): N/A ft2 a.Electric Cap:50 gallons SHGC(AVG): N/A EF:0.97 b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1473.50 ft2 Credits(Performance method) None b.N/A R= ft2 c.N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building fqi ST47 Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise,a new EPL Display Card Will be completed yk�, __ 0r based on installed Code complias n u,,, i••;,;,; :``� f Builder Signature: Date: Address of New Home: C � City/FL Zip'.' 3�Q --s WE `Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/13/2021 8:02 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1 Project SummaryJam'. wri9 htsoftm Entire House Date: Jan 13,2021 QUICK CALCS, INC. 317 ST.LUCIE LN,Fr.PIERCE,FL 34946 Rune:772-466-6799 Fax T72-4666796 Email:QUICKCALCS a(�AOL.COM Project • • For. WYNNE DEVELOPMENT THE STERLING,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outsidedb 42 OF Outsidedb 90 OF Insidedb 70 °F Insidedb 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grfib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18852 Btuh Structure 17877 Btuh Ducts 5654 Btuh Duds 8536 Btuh Central vent(0 cfi n) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24506 Btuh Use manufacturers data In Rate/sw ng multiplier 0.95 Infiltration Equipment sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2958 Btuh Du Central vent(0 cfm)cts2310 BBtuh Heatingg Coolingg (none) Area(f?) 1474 14A Equipment latent load 5277 Btuh Volume(fta) 12227 12227 Airchanges/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 30370 Btuh EquivAVF(dm) 92 47 Req.total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 Cond 25HBC536A 030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh@47-F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cfln Actual air flow 1160 cflT1 Airflowfador 0.047 cfm/Bluh Airflowfador 0.044 cfin/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point=33 OF Backup: Input=7kW, Output=23009 Btuh,100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. ,c wr•ghr6aft- 2021-JaNI308:11:06 r -- RigkSdte®Uriv ml201919.021 RSU08101 Page 1 �..C�R ...oaarler6lWrigh5oRHVACIWYNNE-THESTERLINGnp CaIc=MJ8 FrortDocrfares N +wrightsoft° Right-J®Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. By. 317 ST.LUCIE LN.,FL PIERCE,FL 34W Ptore:772-0 16 799 Fax 772-4666796 Email:QUICKCALCS ,AOL.COM 1 Room name ErNre House MASTER BEDROOM 2 Etglosedwall 1802 It 52.0 ft 3 Room height 83 It d 8A it heaVcool 4 Room dimensions 1.0 x 329.0 ft 5 Room area 14735 ft' 329.0 IF Ty Construction U-value Or HTM Area (IF) Load number (BNhMfz° ( Load Area (ft F) (BWhRF) or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross N/PS Heat Cool Gras N/P/S Heat Cool 6 Vil 13A4o s 0.143 ne 4.00 2.55 479 442 1768 1124 80 80 320 204 �C 1At1= 1270 ne 3556 70.43 38 0 1344 2662 0 0 0 0 13A-4or_s 0.143 se 4.00 2.55 128 83 331 210 0 0 0 0 1Aclom 1270 se 3556 34.77 24 24 848 829 0 0 0 0 11 11DO 0390 se 1092 1131 22 22 236 244 0 0 0 0 W 13A-0as 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 W, 13A4o s 0.143 sw 4A0 2.55 360 353 1414 899 224 224 897 570 1-6 1Ac1om 1270 sw 35M 42.91 7 5 247 298 0 0 0 0 13A4o s 0.143 nw 4.00 2.55 290 217 867 551 112 79 318 202 tAclom 1270 nw 35,56 4524 33 0 1162 1478 33 0 1162 1478 4A5-2om 0.770 rw 21M 2754 41 0 880 1124 0 0 0 0 P 12C-0sw 0.091 - 255 128 192 192 48S 246 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 1474 1474 1320 3419 329 329 295 763 F 22A-t)l 0.989 - 27.69 0.00 1474 180 4989 0 329 52 1440 0 6 0)AED exursim 12000 680 Enrelopelossrgain 16030 44M 3897 12 a) Infiltration 2822 909 249 b) Room ventilation 0 0 0 13 Internal gains: Om,pans@ 230 5 2 460 Appliano�other 0 Submtal(linesft13) 18852 17877 5341 4606 Lesseremalload 0 0 Leastransfer 0 0 0 0 Redistribution0 0 0 0 14 Subtotal 18852 17877 0 5341 4606 15 Duct loads 30% 48°/, 5654 853G 30% 48% 1602 2199 Total room load 24506 26413 6943 6805 Airrequired(c!m) 1160 11 W 329 299 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed ACCwrl9hLso1't^ 2021Jarf1308:11:06 A fLgTHE Se ERLIINGn 2019 Calc=021 RSU08101 ...«xn�erls\WngtAsoR HUAgWYNNE-TiE STERLINGnp CaIc=M18 Frort Doorfaces:N Pagel wrightSoft° RighW@ Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. By. 317 ST.LUCIE LN,Fr.PIERCE,FL 34946 Phone:772466-6799 Fax 772466-6796 Email:OUICKCALCS@AOL.COM 1 Room name WIC M BATH Oft 8.0 ft 3 R height 8.0 ft heaVcool 8.0 ft heaV=l 4 Room dimensions 7.0 x 9.0 It 7.0 x 8.0 ft 5 Room area 63.0 iF 56.0 f Ty Construmon U-value or HTM Area T) Load Area (ft� Load number (BWhA1.2F) (Ehuh4� or penmeter (ft) (Btuh) orpenmeter M (Btuh) Heat Cool Gros NIPS Heat Cool Gros NIPS Heat Cool 6VL_ 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 G 1Acl m 127C ne 3556 70.43 0 0 0 0 0 0 0 0 13A-4ors 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1cm 1270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4o s 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 N/ 13A-4= 0.143 m4.00 255 0 0 0 0 64 57 228 145 �G 1Acl m 1270 av 3556 4291 0 0 0 0 7 5 247 298 13A-4ocs 0.143 m 4.00 2.55 0 0 0 0 0 0 0 0 tAclom 1270 m 3556 4524 0 0 0 0 0 0 0 0 4A5-2cm 0.770 ma 2156 2754 0 0 0 0 0 0 0 0 P 12C-Oav 0.091 - 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 63 63 56 146 56 56 50 130 F 22A-tD1 0.989 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AED exalrsion -2 225 Envelope lossbain 56 w 747 798 12 a) Infiltration 0 0 w 38 b) Roomventlaton 0 0 0 0 13 Intemal gains: O=pants@ 230 0 0 0 0 Applianoa/other 0 0 Subtotal(lines6to 13) 56 145 887 836 Les exemal load 0 0 0 0 Lestran4er 0 0 0 0 Redistnkrion 0 0 0 0 14 Subtotal 56 145 8B7 836 15 DuGloads 30% 48% 17 69 30% 48% 266 399 To6l room loatl 73 214 1153 1235 Air required(,Fm) 3 9 55 54 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrtghlsof - 2021JarN308:11:06 A -'^ ggf-SUte@Lhverm12Ol9l9.021RSU08101 Paget ...oa rts\Wnghtsoft HVAMWYNNE-THESTERLINGnp Calc=MJ8 Frort Ooorfdces N > wrightsoft- Right-JO Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. By 317 ST..LUCIE LPL,FL PIERCE,FL 34946 Phow:772-466.6799 Fa1c 772466£796 Email:OUICKCALCS@AOL.COM 1 Room name KITCHEN BATH 2 E>rpomd vsll 8.0 ft 5A ft 3 Room height 8.0 ft heatbod 8.0 ft hear/mol 4 Rcom dimensons 1.0 x 192.0 ft 9A x 5.0 It 5 Room area 1929 fF 45.0 ff Ty Con&urdon U-Ndw Or HTM Area (" Load rwmber (BWNR'-°g (BWh" or pens (t[) (BWh) wu pwimNar (tt) (Ehuh) Heat Cool Gros N/PS Heat Cool Gros NIPS Heat Cool 6 w " 13A-4= 0.143 ne 4.00 255 0 0 0 0 40 40 160 102 �G 1Ac1am 1270 ne 35ZS 70.43 0 0 0 0 0 0 0 0 I( Vy 13A4a 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 iAMm 1270 w 3556 34.77 0 0 0 0 0 0 0 0 11 11DO 0" se 1092 11.31 0 0 0 0 0 0 0 0 w 13A4ors 0.143 s 4AD 2.55 0 0 0 0 0 0 0 0 13A-4= 0.143 av 4.00 2.55 0 0 0 0 0 0 0 0 t—C 1Actom 1270 w3556 4291 0 0 0 0 0 0 0 0 T13A-fl 0.143 w4A0 2S5 0 0 0 0 0 0 0 0 �—G13A-4=1A-dw 1270 nw 3556 4524 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 2754 0 0 0 0 0 0 0 0 P 12C-Ow OD91 - 2.55 128 64 64 163 82 0 0 0 0 C 16A30md 01M - 090 2.32 192 192 172 445 45 45 40 104 F 22AWI 0989 27.69 0.00 192 8 222 0 45 5 138 0 6 c)AtDe rsion 47 -2 Envelope losrgam 557 501 339 204 12 a) Infilbsim 0 0 87 24 b) Rcomwnlilabon 0 0 0 0 13 trlWmal gains: Ooalpants@ 230 0 0 0 0 Applian¢4odw 2000 0 Subtotal(15nes6W13) 567 2501 426 228 Lme)demallcao 0 0 0 0 Lestransfer 0 0 Redishbuton 0 0 0 0 14 SubWgl 557 2501 426 228 15 DuQlOads 30% 48% 9 1194 30% 48% 128 109 ToW room load 1 724 3695554 AIrrequired(cfm) 34 162 226 315 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed rtFF wri9fi+>r�o>r>t' 2021-Jan1308:11:06 RigTHESTEUHvereav 19 19.021Cac=W8 RSU08101 Page3 ...oarrert;\WrighSoft HVAC\WYNNE-TiE SiERLINGnp Cale=MlB Frort Doorfaces N wrightsoft Right-J@ Worksheet Job: Entire House Dale: Jan 13,2021 QUICK CALCS, INC. sy. 317 ST.LUCIE UN.,FT.PIERCE,FL 34946 Pl ona:M466-6799 Fax 772466.6796 Email:QUICKCALCS@AOL.COM 1 Room name SEDROOM2 ENTRY 2 EVosed mall 322 ft 16.0 It 3 Room height 8.0 ft heaVcool 8.0 It heaV000l 4 Room dimensions 1.0 x 203.5 ft ID x 55A ft 5 Room area 2035 If 55.0 iF Ty Consaudon U-value Or HTM Area (ft') Load Area (fF) Load number (BblhAF-'FF) (BWh4l� or perimeter (ft) (BWh) or perimeter (t) (Btih) Heat Cool Gross NiPS Heat Cool Gross N/PS Heat Cool 13A4= 0.143 ne 4.00 255 128 128 513 326 0 0 0 0 6 VL—G 1Ac1cm 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 13A4ors 0.143 se 4.00 2S5 80 56 225 143 48 26 106 67 1Aclom 1270 sa 35.56 34.77 24 24 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 22 22 236 244 W 13A-0as 0.143 s 4.00 2S5 34 34 136 86 0 0 0 0 13A-0as 0.143 sw 4.00 2S5 16 16 64 41 8 8 32 20 1Ac1om 1270 sw 35.56 42.91 0 0 0 0 0 0 0 0 13A4ors 0.143 nw 4.00 255 0 0 0 0 0 0 0 0 1Ac1cm 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4AS2om 0.770 nw 21.56 27.54 0 0 0 0 0 0 0 0 P 12C-0sx 0.091 2,55 128 0 0 0 0 72 72 183 92 C 16A30md 0.032 - 0.90 2,32 204 204 182 472 55 55 49 128 F 22A-t)l 0.989 - 27.69 0.00 204 32 891 0 55 16 443 0 6 c)AED ex=rsion -24 3 Ernelope lossigain 2859 1873 1049 w 12 a) Infiltration %4 154 122 34 b) Roon-vemlaton 0 0 0 0 13 Intamal gaire: O=Pants@ 230 1 230 0 0 Appliano5siother 0 0 Sublotal(lines 6to 13) 3422 2257 1172 579 Lessexaemalload 0 0 0 0 Leestansfer 0 0 0 0 RedislriMon 0 0 0 0 14 Subtotal 3422 2257 1172 579 15 Durtloads 30% 48% 1026 1078 30% 48% 351 276 Total room load 4449 3335 1523 855 Air requlretl(Qm) 211 146 72 38 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. -rid- wNgbivoTi^ 2021-Jah1308:11.06 RigItSuteCJUriv mI201919.021 RSU08101 Page ...oc rts\Wdgttsot HVACWYNNE-THESTERLING.rip Ca1c=W8 FroNDoorfaces:N -r�wrightsoft° Right-J@ Worksheet Job: Entire House Date: Jan 13,2021 QUICK CALCS, INC. By. 317 SL LUCIE UN.,FT.PIERCE,FL 34946 Phone:772-466-6799 Fac 772-466-6796 Email:QU1CKCALCS@AOL.COM 1 Room name LAUNDRY GREAVDINNG 2 Eposedwall 13.0 It 46.0 It 3 Room height 8.0 it hwV=l 8.9 It heaVmcl 4 Room dimensions 7.0 x 6,0 It1.0 x 488.0 it5 Room area 42.0 IF 488.0 f6 Ty Construction U-value Or HTM Area (f?) Load Area Load number (BWh/IF--q (Bhrh4F) or perimelor (ft) (Btuh) or perimeter (fl) (BNh) Heat Cool Gross NI/P)S Heat Cool Gross NtP/S Heat Cool 6 V" 13A4as 0.143 ne 4.00 2.55 0 0 0 0 231 194 775 493 IA-dom 1270 ne 3556 70.43 0 0 0 0 38 0 1344 2662 13A4c s 0.143 se 4.00 255 0 0 0 0 0 0 0 0 1ALIcm 1270 se 3556 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 1092 11.31 0 0 0 0 0 0 0 0 w 13A4ocs 0.143 s 4.00 2S5 0 0 0 0 0 0 0 0 U+/ 13A4o 0.143 sv 4.00 2.55 48 48 192 122 0 0 0 0 t—G 1Aotom 1270 sw 3556 4291 0 0 0 0 0 0 0 0 �/ 13A-0as 0.143 nw 4.00 2.55 0 0 0 0 178 137 549 349 'L—G 1Ac1om 1270 nw 3556 4524 0 0 0 0 0 0 0 - 0 �—G 4AS2om 0.770 nw 2156 27,54 0 0 0 0 41 0 880 1124 P 12C4hw 0.091 - 255 128 56 56 143 72 0 0 0 0 C 16A30md 0.032 - 090 2.32 42 42 38 97 488 488 437 1132 F 22A-tpl 0389 - 27.69 0.00 42 13 360 0 488 46 1274 0 6 c)AEDexarrsion -3 S6 Envelope lossigain 733 288 5259 5704 12 a) Infiltration 105 29 8% 245 b) Roomventilation 0 0 0 0 13 Internal gains Oocipants@ 230 R837 0 2 460 Applianoss/other 0 0 Subtotal(linas6to 13) 317 6154 6409 Lesseeamal load 0 0 Lesstransfer 0 0 0 0 Redist ibution 0 0 0 0 14 Subtrttal 837 317 0 0 6154 6409 15 Duct loads 30% 48% 251 151 30% 48% 1846 3060 Total room load 1089 468 ggOp gg6g Airrequired(clim) 52 21 379 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed Ad- 2021-Jan1308:11:06 �A RgIYSute@ Universal 201919.021 RSUG8101...owner%MW69HSDft FIVACIWYNNE-THESTERLINGnp Calc=NUB Frort Doorfaces:N Page 6 Duct System SummaryJ°h wrightsoft® � Dam: Jan 13,2021 Entire House BY QUICK CALCS, INC. 317ST.LUCIE LN.,FT.PIERCE,FL 34946Phom:772-466-6799Fa 772466-6796 Emil:QUICKCALCS@AOL.COM Project Information For. WYNNE DEVELOPMENT THE STERLING,FT.PIERCE,FL Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0250 in H2O Lowest fiction rate 0.284 iN100ft 0.284 in/100ft Actual airflow 1160 cfm 1160 cfrn Total effective length(TEL) 176 ft SupplyDetail Table Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (6tuh) (Cfm) (Cfm) FR (in) (in) Mail Ln(ft) Ln(ft) Trunk BATH h 554 26 15 0.376 4.0 Ox0 VIFx 18.1 115.0 st1 BEDROOM h 4449 211 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 ENTRY h 1523 72 38 0.510 5.0 OxO VIFx 3.0 95.0 GREATIDINING C 4735 189 208 0.318 7.0 OxO VIFx 22A 135.0 sl2 GREATIDINING-B C 4735 189 208 0.307 7.0 OxO VIFx 28.1 135.0 s2 KITCHEN C 3695 34 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY h 1089 52 21 0.366 6.0 Ox0 VIFx 21.6 115.0 st1 M BATH h 1153 55 54 0.366 4.0 OxO VIFx 21.6 115.0 st1 MASTERBEDR00%A h 3471 164 149 0.297 6.0 Ox0 VIFx 33.1 135.0 812 MASTERBEDROOM-B h 3471 164 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 WIC c 214 3 9 0.310 4.0 Ox0 VIFx 26.3 135.0 St2 Supply • ' Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 711 724 0284 922 12.0 0 x 0 VinIFIx st1 st1 PeakAVF 1088 1122 0.284 1050 14.0 0 x 0 VinlFlx 2021-Ja 1308'11:06 +�r wright5oft' �� .. RigtlS ive uteOUrrsa1201919.021 RSU08101 Paget Za ..nc r6W,6ghtsoHVHVACNWYNNE-THESTERLING.np Caic=MJ8 Fror[DcorfaMs:N Retum Branch Detail Table Grille Htg Clg TEL Des gn Wloc Diam H x W Stud/Joist Dud Name Size(in) (Ctm) (Cfm) (ft) FR (fpm) (in) (n) Opening(in) Mall Trunk rb1 Ox0 1 1160 1160 0 1 0 0 0 Ox 0 \AFx 41- wrightsof- 2021-Jam1308:1t06 MgttSU*OLkiwrml201919.021 RSW8101 Page 2 ...Odarzr6\WrighSORHVACWYNNE-hIE STERLINGn{� Cak rt D=MIB F000rfa®sN