Loading...
HomeMy WebLinkAboutAPPROVED, ENCODES & MJProject Summary :ems S YS 1 t�0 COHpi i�ON�Np. �M�, Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH. FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com For: HOMECRETE Notes: TROTTER RES Weather: St Lucie Cc Intl, FL, US Winter Design Conditions Outside db Inside db 70 OF Design TD 29 OF Heating Summary Structure 9722 Btuh Ducts Central vent (0 cfm) 2438 0 Btuh Btuh (none) Humidification 0 Btuh Pi In Equipment load 12160 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 HeatingCoolin Area ftz) gg Volume (ft3 65 560 Air changes/hour 0 30 015 Equiv. AVF (cfm) 33 16 Heating Equipment Summary Make CARRIER Trade Model CH16NA018 AHRI ref Efficiency Heating input 8.5 HSPF Heating output Temperature rise 16300 Btuh @ 470F 24 OF Actual air flow 625 cfm Air flow factor Static pressure 0.051 cfm/Btuh 0.10 in H2O Space thermostat Capacity balance point = 0 OF Backup: CARRIER 5 KW Input = 3 kW, Output = 10608 Btuh, 100 AFUE Job: Date. By: LINDSTROM Summer Design Conditions Outside db 95 OF Inside db OF Design TD 15 OF Daily range Relative humidity L Moisture difference 50 57 % gr/ib Sensible Cooling Equipment Load Sizing Structure Ducts 9258 Btuh Central vent (0 cfm) 3730 0 Btuh Btuh ( none) Blower 0 Btuh Use manufacturer's data Rate/swing y multiplier Equipment sensible load 1.00 12988 Btuh Latent Cooling Equipment Load Sizing Structure 1032 Btuh Ducts Central vent (0 cfm) 932 0 Btuh Btuh (pone) Equipment latent load 1964 Btuh Equipment Total Load (Sen+Lat) Req. total capacity at 0.84 SHR 14952 1.3 Btuh ton Cooling Equipment Summary Make CARRIER Trade Cond CH16NA018 Coil FX4DNF019 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 14400 Btuh 2700 Btuh 17100 Btuh 625 cfm 0.048 cfm/Btuh 0.10 in H2O 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t wrightsott, ^— ^Mw•=• Right-Suitee universal 2019 19.0.12 RSU08398 2021•Sep-1518:03:57 '�� ...GY1A- MANUAL JIHOMECRETE-TROTTER 2021 SPLIT.rup Cale = MJ8 Front Door faces: N Page 1 Pro'ect Summary "U,Vw S Y 2 Lindstrom Air Conditioning 3581 W MCNAB RD. POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420.0064 Web: wwwAndstromaircom For: HOMECRETE Notes: TROTTER RES Weather: St Lucie Co Intl, FL, US Winter Design Conditions Outside db Inside db 70 °F Design TD 29 OF Heating Summary Structure 23407 Btuh Ducts 6458 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Pi in Equipment load 29865 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft3) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 He 2336 Co 2336 22208 22208 0.33 0121 60 Heating Equipment Summary Make CARRIER Trade Model CH16NA048 AHRI ref Efficiency Heating input 9 HSPF Heating output Temperature rise 42400 Btuh @ 470F 26 OF Actual air flow 1462 cfm Air flow factor Static pressure 0.049 cfm/Btuh Space thermostat 0 in H2O Capacity balance point = 0 OF Backup: CARRIER 7.5 KW Input = 8 kW, Output = 28784 Btuh, 100 AFUE Job: Date: By: LINDSTROM Summer Design Conditions Outside db 95 °F Inside db Design TD 15 OF Daily range L Relative humidity Moisture difference 50 57 % gr/lb Sensible Cooling Equipment Load Sizing Structure Ducts 25542 Btuh Central vent (0 cfm) 9435 0 Btuh Btuh ( none) Blower 0 Btuh Use manufacturer's data Rate/swing y multiplier Equipment 1.00 sensible load 34977 Btuh Latent Cooling Equipment Load Sizing Structure 2733 Btuh Ducts Central vent (0 cfm) 2408 0 Btuh Btuh (none) Equipment latent load 5141 Btuh Equipment Total Load (Sen+Lat) 40118 Btuh Req. total capacity at 0.85 SHR 3.4 ton Cooling Equipment Summary Make CARRIER Trade Cond CH16NA048 Coil FB4CNP061 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 38400 Btuh 7000 Btuh 45400 Btuh 1462 cfm 0.042 cfm/Btuh 0 in H2O 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsofta w - - ••• .- Right-SuRe®Universal 2019 19.0.12 RSU08398 2021-Sep 15 18:03:57 GYIA- MANUAL AHOMECRETE-TROTTER 2021 SPLIT.rup Calc = MJ8 Front Door faces: N Page 2 Right-JQ Worksheet Job: S 1S Date: Lindstrom Air Conditioning BY: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone- 9Se-a9i-e117 cam... e.. - wvow. www.jinoslomalr.com 1 Room name LIVING ROOM 2 Exposed wall SYS 1 3 Roan height 113.0 ft 50.0 ft 4 Room dimensions 10.0 ft 10.0 ft heat/cool 5 Room area 656.0 ft 2 11.0 275.0 ft2 x 25.0 ft TY Construction number U-value (Btuh/ft' °F) Or HTM Area (ft� Load Area (ft2 Load (Btuhrk2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 13A-4ocs 0.143 ne 0.00 0.00 0 0 0 106-m 1 D-h2an 0.250 ne 0.00 0,00 0 p 0 0 0 0 0 0 0 p 1 D-h20m 0.320 0.320 ne ne 0.00 0.00 0. 00 0.00 0 0 U 0 0 0 p p 11 1 D-h2om 0.320 ne 0.00 0.00 0 0 p 0 p 0 p 0 0 0 p 1E-h2fm 13A-40Cs 0.260 ne 0.00 0.00 0 0 0 0 p 0 0 --G 1 D-h2om 0.143 0.310 se se 4.15 0.00 2.59 0.00 440 390 1617 1009 320 270 1120 699 ��----GG 113-h2omd 1E-h2fm 0.330 0.260 se 9.57 29.53 0 50 0 28 0 479 0 1477 0 50 0 14 479 1477 13A-4ocs 0.143 se sw 0.00 4.15 0.00 2.59 0 260 0 228 0 937 0 0 0 0 106-m 106-m 0,250 sw 7.25 20.98 24 14 174 585 503 140 24 111 7 460 28� 1 D-h2om 0.250 sw 0.00 0.00 0 0 0 0 0 0 174 0 503 ID-h2om 0.310 0.310 sw sw 0.00 0.00 0.00 0.00 0 0 0 p 0 0 0 0 1D-h2omd 1E-h2fm 0.330 sw 0.00 0.00 0 0 0 0 0 0 0 0 0 VjJ 13A-4ocs 0.260 0.143 sw nw 7.54 4.15 13.23 2.59 10 20 75 132 5 5 0 6 �L-_Gp 1D-h2om 1100 0.310 nw 8.99 34.92 115 32 83 0 344 288 215 1117 0 0 0 12B-0sw 0.390 0.097 nw - 0.00 2.81 0.00 1.60 0 0 0 0 0 0 0 0 p C 1100 16B-38md 0.390 se 11.31 11.43 315 44 271 44 762 498 434 603 40 22 18 22 51 207 29 F 22A-tpi 0.026 0.989 sw - 0.75 28.68 1.37 0.00 656 656 656 495 901 275 275 207 251 378 105 3012 0 275 42 1205 0 excursion 446 49 e loss/gain V12a) 8680 7322 3982 3739 tration an ventilation 1042 277 588 156 0 0 0 0 13 Internal gains: Occupants 230 2 Appliance s/ootthers 460 0 1200 0 Subtotal (lines 6 to 13) 9722 92581 4570 3895 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 T40%.1146 0 0 Ductloads 25% 40% 9722 2438 9258 3730 25% 4570 3895 1569 ft d �Air�requireci fm) 1 12160 12988 5715 5464 5 625 294 263 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A + wrlgt�tsoit� 2021-Sep-1518:03:57 ...GYIA- MANUAL JIHOMECRETUniversal E TROT ER2021SPLIIT2019 11=8 rup Calc MJ8Front Door faces: N Page 1 Right-J® Worksheet Job: S T Sr i Date: Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.Iindstromair.com 1 R;name2 Ex LAUNDRY 1ST FLR BED 3 Ro 15.0 ft 24.0 ft 4 Roons 10.0 ft heat/cool 10.0 ft heat/cool 5 Ro 9.0 x 7.0 ft 13.0 x 12.0 ft 63.0 ft' 156.0 ftzTyruction number U value Or (Btuh/ft�-°F) HTM Area (M Load Area (ft� Load (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat cool Gross N/P/S Heat Cool 6 13A-40cs 0.143 ne 0.00 0.00 0 0 108-m 1D-h2om 0.250 ne 0.00 0.00 0 p 0 0 0 0 0 0 0 1 D-h2om 0.320 ne 0.320 ne 0.00 0.00 0 0.00 0.00 0 p p 0 0 0 0 0 0 11 1 D-h2om 1E-h2fm 0.320 ne p 0.00 0.00 0 p 0 0 0 0 0 0 0 0 0 13A-4ocs 0.260 ne 0,143 se 0.00 0.00 0 4.15 2.59 0 0 0 0 0 1 D-h2om ID-h2omd 0.310 se 0 0.00 0.00 0 0 p 0 0 0 0 0 0 0 0 1E-h2fm 0.330 se 0.260 9.57 29.53 0 0 0 0 0 0 0 p p W 13A-4ocs se 0.143 sw 0.00 0,00 0 4.16 2.59 p 0 0 0 0 0 0 0 10B-m 106-m 0.250 sw 7.25 20.98 0 0 0 0 0 0 0 0 0 0 0 1D h2om 0.250 sw 0.310 sw 0.00 0.00 p 0.00 0.00 0 0 0 0 0 0 0 1 D-h2om ID-h2omd 0.310 sw 0 0.00 0.00 0 0 p 0 0 0 0 0 0 0 0 1E-h2fm 0.330 sw 0.260 0.00 0.00 p 0 0 0 0 0 0 0 0 yJ 13A-4ocs sw 0.143 nw 7.54 13.23 p 4.15 2 59 0 p 0 0 0 0 ID-h2om 0.310 nw 0 8.99 34.92 0 0 p p 0 132 83 217 11D0 12B-0sw 0.390 nw 0.00 0.00 0 0 0 0 0 2344 88 88 111 11 DO C 0.097 - 0.390 se 2.81 1.60 150 11.31 11.43 22 128 22 360 205 125 125 352 200 16B-38md F 22A"tpl 0.026 sw 0.75 1.37 63 63 249 48 251 86 0 156 0 156 0 0.989 - 28.68 0.00 63 15 430 0 156 24 118 688 214 p 6 c) AED excursion 87 Envelope loss/gain 415 1087 456 1789 2161 12 a) Infiltration b) Room ventilation 0 0 147 39 13 1ntemal gains: Occupants @ 230 0 0 0 Appliances/other 0 2 460 1200 0 Subtotal (lines 6 to 13) 1087 1656 1936 2660 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 25% An% 1 1087 272 16M 667 25% 40% 1936 2660 Total room bad 486 1072 Air required (cfm) 1359 2323 2422 3732 70 112 124 180 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. f*- wr�ghtsoTt^ '�'A Universal1 2021-Sep-15 18:03:57 ...GY1A- MANUAL JIHOMECRETE TROTTER2021SPLIT. up Calc = MJ8 Front Door faces: N Page 2 R' �J® Worksheet Job: Date: Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420.0064 Web: www.lindstromair.com name d wall WIC 1ST FLR BED BATH 1ST FLR BED height 0 ft 24.0 ft r4ftom dimensions 10.0 ft heat/cool 10.0 ft heat/cool area 7.0 x 6.o ft x 10.o ft 42.0 ft Z120.0 z12.0 ftConstruction U-value Or HTM Area (ft2) Loadq : number (Btuh/ft2 °F) (Btuhlft� or perimeter (ft) (Stuh) ) Load or perimeter (ft) (Bt ) Heat cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 ne 0.00 0.00 0 0 10B-m 1 D-h2om 0.250 ne 0.00 0.00 0 0 0 0 0 0 0 0 1 p h2om 0.320 ne 0.320 ne 0.00 p, pp 0 0 0.00 0.00 0 0 0 0 0 0 0 0 0 11 1 D-h2om 1 E-h2fm 0.320 ne 0 0.00 0.00 0 p 0 0 0 0 0 13A-0ocs 0.260 ne 0.143 se 0.00 0.00 0 0 0 0 0 0 p 0 1D-h2om 0.310 se 4.15 2.59 0 0 0.00 0.00 0 0 0 120 120 498 311 1D-h2omd 1E-h2fm 0.330 se 0 9.57 29.53 0 p 0 0 0 0 0 0 0 0 0 W 13A-40cs 0.260 se 0.143 sw 0.00 0.00 0 0 4.15 2.59 0 0 0 0 0 0 p 0 0 1OB-m 106-m 0.250 sw p 0 20.00 0 0 0 0 0 120 0 115 477 �0 10-h2om 0.250 sw 0.310 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 ID-h2om sw 0.310 sw 0.00 0.00 0 0 0.00 0.00 0 0 p p 0 p 1D-h2omd 0.330 sw 0 0.00 0.00 0 0 0 p 0 0 0 1E-h2fm If�l 13AAocs 0.260 sw 7.54 13,23 0 0 p 0 0 5 5 0 ��-(p` 1 D-h2om 0.143 rnv 0.310 nw 4.15 2.59 p p 8, 99 34.92 0 0 0 0 6 11D0 1-0 12B-Osw 0.390 nw 0.097 0 0 0.00 0.00 0 0 0 0 0 p 0 0 0 0 p 11D0 - 0.390 se 2.81 1.60 0 0 11.31 11.43 0 0 p p 0 0 0 0 C 16B-38md F 22A-tpl 0.026 sw 0.989 0.75 1.37 42 42 0 32 0 58 120 120 90 - 28.68 0.00 42 0 0 0 120 24 688 165 0 6 c) AED excursion -3 72 Envelope loss/gain 32 55 1791 911 12 a) Infiltration 307 81 b) Room ventilation 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 0 0 0 0 Subtotal (lines 6 to 13) 2098 992 32 55 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 259/o 40-/.j 32 8 55 22 25% 40% 2098 526 992 400 Total room load Air required (cfm) 42 4 2624 1392 135 67 Calculations approved b ACCA to meet all requirements of Manual J 8th Ed. wrEgF�tsoiC� 1C��.-f� ...GY\A- MANUAL J\HOMECRET Universal E TROTTER202a1=8 2021-Sep-1518:03:57 SPLIT.rup Calc MJ8Front Door faces: N Page 3 R_�iCC��ht-J® Worksheet Job: SYS 2 Date: Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromaircom 1 Room name BED 3 2 Exposed wail SYS 2 3 Room height 135.5 ft 0 ft 4 Room dimensions 9.5 ft 9.0 ft heat/coci 5 Room area 2336.0 ft2 17.0 x 19.0 ft 323.0 ft' Ty Construction number U-value (BtuWft'-°F) Or HTM Area (ft� Load Area (ft') Load (Btuhlft� or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-40cs 10B-m 0.143 0.250 ne 4.15 2.59 1160 997 4135 2681 170 139 576 360 1D-h2om 0.320 ne ne 7.25 9.28 25.23 35,07 24 62 0 174 606 0 0 0 0 11 1 D h2om 1 D-h2om 0.320 ne 9.28 35.07 31 0 0 575 288 2174 1087 31 0 p 288 1080 1E-h2fm 0.320 0.260 ne ne 9.28 7.54 35.07 34.15 31 0 288 1087 0 0 0 0 0 0 13A-4ocs 1 D-h2om 0.143 se 4.16 2.59 15 465 0 429 113 1779 512 1110 0 190 185 0 TE� 1D-h2omd 0.310 0.330 se se 8.99 0.00 35.22 0.00 31 0 279 1092 0 0 7677 0 479 0 W 1E-h2fm 13A-4ocs 0.260 0.143 se 7.54 13.23 0 5 0 10 0 38 0 Be 0 p 66 10B-m 0.250 sw sw 4.16 0.00 2.59 0.00 1125 0 857 0 3554 2218 250 189 784 489 108-m 1D-h2om 0.250 0.310 sw sw 7.25 8.99 9.59 90 180 0 653 0 8,33 0 45 0 45 p 326 432 ID-h2om 1D-h2omd 0.310 sw 8.99 14,00 14.00 16 64 32 128 144 575 224 896 16 0 16 144 224 1E-h2fm 0.330 0.260 sw sw 9.57 0.00 14.31 0.00 98 198 938 1402 0 0 0 0 0 0 0 V�J 13A flocs 1 D-h2om 0.143 nw 4.15 259 0 260 0 238 0 987 0 616 p 0 0 0 0 �-GD 11D0 0.310 0.390 nw r1w 0.00 11.31 0.00 11.43 0 22 0 22 0 0 0 p 0 0 0 0 12B-Osw 11 DO 0.097 - 2.81 1.60 150 150 249 422 251 240 0 0 0 0 0 C 16B-38md 0.390 0.026 se sw 0.00 0.75 0.00 1.37 0 1212 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 28.68 0.00 1184 1212 121 914 3456 1664 0 323 0 323 244 443 0 0 0 6 c) AED excursion 645 4171 Envelope loss/gain 3166 4225 19559 22861 12 a) Infiltration 780 207 b) Room ventilation 3848 48 1022 0 0 0 13 Internal gains: Occupants @ 230 2 Appliances/other 460 1 230 1200 0 Subtotal (lines 6 to 13) 23407 25542 3946 4662 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 15 Duct loads 23407 25542 3946 4662 280/u 37% 6458 9435 371/6 50% 1441 2319 Total room load Air required (cfm) 29865 34977 5387 6981 1462 1462 264 292 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -�}+ wrightsoTt 4C�A ..GY1A- MANUAL J\HOMECRETv1 2021-Sep-1518:03:57 2019 1CalcUMJ8 E-TROTTER ER202aSPLIT.upFront Door faces: N Page 4 rss etac..e SYS J� Worksheet 2 Job: CPOII� Date: Lindstrom Air Conditioning By; LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromair.com 1 Room name BATH BED 3 2 Exposed wall WIC BED 3 3 Room height O ft O ft 4 Room dimensions 9.0 ft heat/cool 9.0 ft heat/cool 5 Room area 8.0 x 7.0 it 9.5 x 9.0 ft 56.0 ft a 85.5 ftz Ty Construction number U-value (Btuh/ftz°F) HTM Area (W) Load Area (ft� Load ;ne (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Gross N/P/S Heat cool Gross N/PIS Heat Cool Heat Cool 6 13A-4ocs 0.143 4.15 2.59 0 0 0 106-m 1 D-h2om 0.250 7.25 25.23 0 0 0 0 80 0 75 0 311 194 ID-h2om 0,320 0.320 ne ne 9.28 9.28 35.07 35.07 0 0 0 0 0 0 0 0 0 0 0 11 1 D-h2om 0.320 ne 9.28 35.07 p 0 p 0 0 0 0 0 0 0 0 1 E-h2fm 13A-4ocs 0,260 0.143 ne 7.54 34.15 0 0 0 0 0 0 5 0 p 0 38 0 171 1 D-h2om 0.310 se se 4.15 8.99 2.59 35.22 0 0 0 0 p p 0 0 0 1D-h2omd 1E-h2fm 0.330 se 0.00 0.00 0 p 0 0 0 0 0 0 0 0 0 W 13A-40ts 0.260 0.143 se sw 7.54 4.15 13.23 2.59 0 p 0 0 0 0 0 0 0 0 106-m 1OB-m 0.250 sw 0.00 0.00 0 0 0 0 0 0 0 0 0 0 ID-h2om 0.250 sw 7.25 9.59 0 0 0 0 0 0 0 0 1 D-h2om 0.310 0.310 sw sw 8.99 8.99 14.00 14.00 0 0 0 0 0 0 0 ID-h2cmd 0.330 sw 9.57 14.31 0 0 0 0 0 0 0 0 0 �f 1E-h2fm 13A-4ocs 0.250 0.143 sw 0.00 0.00 0 0 0 0 p 0 0 0 0 (l-_-Gp 1D-h2om 0.310 nw nw 4.15 0.00 2.59 0.00 0 0 0 0 0 0 0 p 11DO 12B-Osw 0.390 0.097 nw 11.31 11.43 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11D0 0.390 - se 2.81 0.00 1.60 0.00 0 0 0 0 0 0 0 0 0 0 C F 16B-38md 2ZA-tPl 0.026 0.989 sw 0.75 1.37 56 56 0 42 0 77 0 86 0 86 0 64 p 117 - 28.68 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -5 -31 Envelope loss/gain 42 72 413 451 12 a) Infiltration b) Room ventilation 102 27 0 0 0 0 13 Internal gains: Occupants @ 230 0 Appliarr Am/other 0 0 0 0 0 Subtotal (lines 6 to 13) 42 72 515 478 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 37% 50% 42 15 72 36 37% 50% 515 188 476 238 Total room load Air required (cfm) 53 108 T34 704 716 5 30 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed Ad-wrl9~�� Right -Suite® Universal 2019 19.0.12 RSU08398 2021Sep-1518:03:57 ...G11A- MANUAL AHOMECRETE-TROTTER 2021 SPLIT.rup Calc = MJ8 Front Door faces: N Page 5 ,~ SYS 2 ®Worksheet Job: Date: Lindstrom Air Conditioning By: LINDSTROM 3681 W MCNAB RD, POMPANO BEACH. FL 33069 Phone: 954-491-A117 cam,. ocn - w• �r +�� �� + ..cu. www.nnusiromair.com 1 Room;:; BED 2 2 Expo TIOLET BATH 3 3 Room0 ft 0 ft 4 Room 9.0 ft heat/cool 9.0 ft heat/cool 5 Room 4.0 x 5.0 ft 15.0 x 15.0 ft20.0 ftz 225.0 ft'Tyionalue (fM Load (Btalu °F) Orer HTM� Area (ft� Load Area (Btuhrft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS 119 Heat 493 Cool 6 13A-4ocs 1013-m 0.143 ne 4.15 2.59 40 40 166 104 150 1 D-h2om 0.250 0.320 ne 7.25 25.23 0 0 0 0 0 0 0 308 0 1 D-h2om 0.320 ne ne 9.28 9.28 35.07 35.07 0 0 0 0 0 0 31 0 288 1067 11 1 0-h2om 0.320 ne 9.28 35.07 0 0 0 0 0 0 0 0 0 1E-h2fm 13A flocs 0.260 ne 7.54 34.15 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.143 0.310 se 4.15 2.59 0 0 0 0 0 0 0 0 1D-h2omd 0.330 se se 8.99 0.00 35.22 0.00 0 p 0 0 0 0 0 0 0 W iE-h2fm 13A-flocs 0.143 se 13.59 0 0 0 0 0 0 0 0 0 0 0 0 0 10B-m 0.250 0.250 sw sw 4.15 4.00 2.00 0.00 0 0 0 0 0 0 0 0 0 0 108-m 0.250 sw 7.25 7.25 9.59 0 0 0 0 0 0 0 0 0 0 p i D-h2om 0.310 sw 8.99 14.00 0 0 0 0 0 0 0 0 1 D-h2om 0.310 sw 8.99 14.00 0 0 0 0 0 0 0 1D-h2omd 0.330 sw 9.57 14.31 0 0 0 0 0 0 0 0 1�f 1E-h2fm 13A-4ocs 0.260 sw 0.00 0.00 0 0 0 p 0 0 0 0 0 0 0 ��Gp 1 D-h2om 0.143 0.310 nw nw 4.15 0.00 2.59 0.00 0 p 0 0 0 0 0 0 0 11DO 12B-Osw 0,390 nw 11.31 11.43 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 il-D 11 DO 0.097 0.390 - se 2.81 0.00 1.60 0.00 0 0 0 0 0 0 0 0 0 0 C F 166-38md 22A-tpl 0.026 sw Q75 1.37 20 0 20 0 15 0 27 0 225 0 225 0 170 0 309 0.989 - 28.68 0.00 0 0 0 0 0 0 0 0 6 c) AED excursion -9 -122 Envelope loss/gain 181 122 951 1582 12 a) Infiltration b) Room ventilation 511 144 192 51 0 0 13 Intemal gains: Occupants @ 230 p Appliances/other 0 1 230 0 0 Subtotal (lines 6 to 13) 232 136 1143 1863 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 232 136 1143 1863 370/6 50% 85 67 37% 50% 417 927 Total room load Air required (cfm) 3117 208 1560 2790 6 76 117 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. '4t&�- wrlgFstsoft^ 2021-Sep-15 18:03:57 ...GY1A- MANUAL AHOMECRE hE TROT ERV20211 SPLIT.rup 2019 1Calc U MJ88 Front Door faces: N Page 6 w R' ?J® Worksheet Job: SVSr Date: Lindstrom Air Conditioning BY: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone 954-491-4117 car ate - . - -- • • ^^• �V'+"'rGV-VVpY vvea: www.unastromair.com ame wall BATH BED 2 WIC BED 2 ight 0 ft 0 ft T2Exp:;osed mensions 9.0 ftteat/cool 9.0 ft heat/cool ea 6.0 x 9.0 ft 6.0 x 6.0 ft 54.0 ft' 36.0 ft'Construction number U-value (Btuh/ft? °F) Or HTM Area {ft� Load q (Btuh/ft2) or perimeter (ft) (Btuh) or perimrea eter er (ft) (Bttuuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 13A flocs 106-m 0.143 ne 4.15 2.59 60 55 228 142 0 1 D-h2om 0.250 0,320 ne ne 7.25 25.23 0 0 0 0 0 0 0 0 0 0 0 i D-h2om 0.320 ne 9.28 9.28 35.07 35.07 0 p 0 0 0 p 0 0 11 1 D-h2om 1E-h2fm 0.320 ne 9.28 35,07 0 0 0 0 0 0 0 0 13A-4ocs 0.260 0.143 ne se 7.54 34.15 5 0 38 171 0 0 0 0 0 0 1 D-h2om 0.310 se 4.15 8.90 2.59 35.22 0 0 0 0 0 0 0 0 1D-h2omd 1 E-h2fm 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 0 0 13A-4ocs 0.260 0.143 se sw 7.54 4.15 13.23 2.59 0 0 0 0 0 0 0 0 0 0 0 0 1OB-m 1OB-m 0.250 sw 0.00 0.00 p 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.250 sw 7.25 9.59 0 0 0 0 0 0 p 0 p 1 D-h2om 0.310 0.310 sw sw 8.99 8.99 14.00 14,00 0 0 0 0 0 0 0 0 1D-h2omd 0.330 sw 9.57 14.31 0 0 0 0 0 0 0 1E-h2fm 13A-4ocs 0.260 sw 0.00 0.00 0 p 0 0 0 0 0 0 0 0 0 0 I�-GD 1 D-h2om 0,143 0.310 nw nw 4.15 0.00 2.59 0.00 0 p 0 0 0 0 0 0 0 p Fi 11D0 12B-Osw 0.390 nw 11.31 11.43 0 0 0 D 0 0 0 0 0 0 0 0 0 0 �--D 1100 0.097 0.390 - se 2.81 0.00 1.60 0.00 0 0 0 0 0 0 0 p 0 p 0 C F 16B-36md �'tpl 0.026 sw 0.75 1.37 54 0 54 p 41 74 36 36 0 20 0 0.989 - 28.68 0.00 0 0 0 0 0 0 40 6 c) AED excursion -3 -25 Envelope loss/gain 307 362 27 46 12 a) Infiltration b) Room ventilation 77 20 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 AppliancesJother 0 0 0 0 Subtotal (lines 6 to 13) 27 46 383 383 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 Duct loads 383 383 27 46 37% 509b 140 190 37% 50% 10 23 tA TotaH ad:::7 - ir r(cfm) 523 6731 1 1 37 69 26 24 - 2 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsolt 2021-Sep-1518:03:57 ...GY1A- MANUAL J%HOMECRETUniversal E TROT OTTER SPLIT.2019 i=8 rup Calc MJ8Front Door faces: N Page 7 C900! Y SS 2J® Worksheet Job: Date: Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 - www.unasiromaircorn 1 Room name DEN BATH 2 Exposed wall STAIRS 3 Room height 31.0 ft 26.5 ft 4 Room dimensions 9.0 ft heat/cool 10.0 ft heat/cool 5 Room area 30.0 x 11.8 ft 12.0 x 7.9 ft 352.5 ftz 95.0 ft' Ty tion U-value (Btuh/ft' °F) Or HTM Arearea (ft� Load ;13A (Btutt/ft� or perimeter (ft) (Bttuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 0.143 ne 4.15 2.59 170 165 684 427 p 0 p 1 D-h2om 0.250 0.320 re ne 7.25 9.28 25.23 35.07 0 0 0 0 0 0 0 0 0 0 11 1 D-h2om 1 D-h2 0.320 ne 9.28 35.07 p 0 0 0 0 0 0 0 0 0 0 0 p tE-h2fm 0.320 0.260 ne ne 9.28 7.54 35.07 34.15 0 5 0 0 0 0 0 0 0 0 0 13A-4ocs 0.143 se 4.15 2.59 0 0 0 38 171 0 0 0 1D-h2om 1 D-h2omd 0.310 se 8.99 35.22 0 0 0 0 0 0 120 0 120 p 498 3111 1E-h2fm 0,330 0.260 se se 0.00 7.54 0.00 13.23 0 0 p 0 0 0 0 0 W 13A-40cs 10B-m 0.143 sw 4.15 2.69 380 0 303 0 1257 784 75 75 3111 106-m 0.250 0.250 sw sw 0.00 7.25 0.00 9.59 0 0 0 0 0 0 0 194 0 1 D-h2om 0.310 sw 8.99 14.00 45 0 45 0 326 432 0 0 0 0 1 D-h2om 1D-h2omd 0.310 0.330 sw 8.99 14.00 32 32 0 288 0 448 0 0 0 0 0 0 0 1E-h2fm 0,260 sw sw 9.57 0.00 14.31 0.00 0 0 0 0 0 p 0 0 0 TJD13A-4ocs 1 D-h2om 0.143 rnv 4.15 2.59 190 190 0 788 0 492 0 70 48 199 11 DO 0.310 0.390 rtw 0.00 0.00 0 0 0 0 0 0 0 124 R L--D 126-0sw 0.097 nw - 11.31 2.81 11.43 1.60 0 150 0 0 0 22 249 251 1 11 DO 0.390 se 0.00 0,00 0 150 0 422 0 240 0 0 0 0 0 C F 16B-38md 22A-tpi 0,026 0.989 sw - 0.75 28.68 1.37 0.00 353 353 266 494 0 60 0 60 0 45 p 80 0 0 0 0 95 27 760 6 c) AED excursion 1319 -65 Envelope loss/gain 4068 4797 2062 898 12 a) Infiltration b) Room ventilation 946 251 339 90 0 0 13 Intemal gains: Occupants 230 0 Appliances/otther 0 0 0 0 0 Subtotal (lines 6 to 13) 5014 5048 2401 988 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 5014 5048 2401 988 37% 50% 1831 2511 37% 50% 877 491 Total room load Air required (cfm) 6845 7559 1 1 3277 1479 335 316 160 62 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrigF�t .oft 8:03:5715 Sep-1 Right -Suite® Universal 2019 19.0.12 RSU06398 2021- ...GYtA- MANUAL JIHOMECRETE-TROTTER 2021 SPLIT.rup Cale = MJ8 Front Door faces: N Page 8 ht k"d' w R" 2J0 Worksheet Job: Date: Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.11ndstromair.com 1 Room name 2 Exposed wall DEN WIC DEN 3 Room height 0 ft 6.0 ft 4 Room dimensions 10.0 ft heat/cool ft c� ft 5 Room area 16.0 x 13.0 6.0 x 7.0 ft 2.0 208.0 ft242.0 ft Area (ft') Load Area Ty Construction number U-value (Btuhlft� °F) Or HTM (Btuhlft') or perimeter (ft) (Stuh) or perimeter (ft) (� ) Heat Cool Gross 130 NIP/S 99 Heat 411 Cool Gross N/P/S Heat Cool 6 13A-4ocs 106-m 0.143 0.250 ne ne 4.15 7.25 2.59 25.23 256 60 60 249 155 1 D-h2om 1 D h2om 0.320 ne 9.28 35.07 0 0 0 0 0 0 0 0 0 0 0 0 0 11 1 D-h2om 0.320 0.320 ne ne 9.28 9.28 35.07 35.07 31 0 288 1087 0 p 0 0 0 0 1 E-h2fm 0.260 ne 7.54 34.15 0 0 0 0 0 0 0 0 0 p p 0 0 L13A-4ocs ::CG ID-h2om 0.143 0.310 se se 4.15 8.99 259 35.22 155 124 514 321 321 0 0 0 0 0 0 1D-h2omd 0.330 se 0.00 0.00 31 0 0 p 279 1 0 0 0 0 W 1E-h2fm 13A-40cs 0.260 se 7.54 13.23 0 0 0 0 0 0 0 0 0 0 0 p 10B-m 0.143 0.250 sw sw 4.15 0.00 2.59 0.00 p 0 0 0 0 0 0 0 0 p 0 108 -m 0 .250 sw 7.25 9.59 D 0 0 0 0 0 0 0 0 0 0 1D h2om 1 D-h2om 0.310 sw 8.99 14.00 0 0 0 0 0 p 0 p 0 0 1D-h2omd 0.310 0.330 sw sw 8.99 9.57 14.00 14.31 0 p 0 0 0 0 0 0 0 0 Vhl 1E-h2fm 13A-4ocs 0.143 sw 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �t--Gp 1 D-h2om 0.310 0.310 nw nw 4.15 0.00 0.00 2.59 2.00 0.00 0 0 0 0 0 0 0 0 0 11D0 12B-0sw 0.390 nw 11.31 11.43 0 0 0 0 0 0 0 0 0 0 0 0 0 0 R L- p 11 DO 0.097 a 390 - se 2.81 0.00 1.60 0.00 0 0 0 0 0 p 0 0 0 0 0 C F 166-38md 0.026 sw 0.75 1.37 0 0 0 0 0 0 0 0 p 22A-tpl 0.989 - 28.68 0.00 208 0 0 0 42 6 p 172 6 c) AED excursion t1E -75 -11 Envelope loss/gain 421 144 1491 2681 12 a) Infiltration 77 20 b) Room ventilation 364 97 0 0 0 0 13 Intemal gains: Occupants @ 230 0 Appliances/oftr 0 0 0 0 0 Subtotal (lines 6 to 13) 1855 2778 498 165 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 oads 1855 2778 498 165 WAc 0°Ao 0 0 -0% 0% 0 0 oom load JA�irrequired (cfm) 1855 2778 1 498 185 91 116 247 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed _ +�+ wrl9t+tsoft 2021-Sep-1518:03:57 '�p ...GY1A- MANUAL JIHOMECRETE-TROTTER V20211 1Calc = SPLIT up MJ88 Front Door faces: N Page 9 o SWS'R" 2 ® Worksheet Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone Q.S4-Aqi am cam,.. Job: Date: By: LINDSTROM - • • • • • �� av woY vveu: www. imasvomair.com 1 Room name GRT RM KITCHEN 2 Exposed wall PANTRY 3 Room height 0 ft 72.0 ft 4 Room dimensions 10.0 ft heat/cool 10.0 ft heat/cool 5 Room area 10.0 x 6.0 ft x 20.5 ft 60.0 ft, 238.0 779.0 ft Ty Construction number U-value (Btuh/W-1F) Or HTM Area (ft') Load Area (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btu) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 8 13A-40cs 0.143 ne 4.15 2.59 0 0 0 108 m 1D-h2om 0.250 ne 7.25 25.23 0 0 0 0 0 300 24 245 0 1016 634 1 D-h2om 0.320 0.320 ne 9.28 35.07 0 0 0 0 0 0 174 0 606 0 11 1 D h2om 0.320 ne ne 9.28 9.28 35.07 35.07 0 0 0 0 0 0 0 0 p 1E-h2fm 13A flocs 0.260 ne 7.54 34.15 0 0 0 0 0 0 31 0 0 0 288 1 pgj 1D-h2om 0.143 0.310 se se 4.15 8.99 2.59 35.22 0 0 0 0 0 0 0 p 0 0 1D-h2omd 0.330 se 0.00 0.00 0 0 0 0 0 0 0 0 0 1E-h2fm 13A-4ocs 0.260 se 7.54 13.23 0 0 0 0 0 0 p 0 0 1OB-m 0.143 0.250 sw sw 4.15 0.00 2.59 0.00 0 0 0 0 0 420 290 1203 7511 10B-m 1 D-h2om 0.250 sw 7.25 9.59 p 0 0 0 0 0 0 0 0 0 0 0 0 0 1 D-h2om 0.310 0.310 sw sw 8.99 8.99 14.00 14,00 0 0 0 0 0 0 0 0 0 1D-h2omd 0.330 sw 9.57 14.31 0 0 0 0 0 0 0 0 32 32 288 448 wJ 1E-h2fm 13A-4ocs 0.260 sw 0.00 0.00 0 0 0 0 98 0 98 0 938 1402 �L---CD 1D-h2om 0.143 0.310 nw nw 4.15 0.00 2.59 0.00 0 0 0 0 0 0 0 0 0 0 p 11 DO 12B-0sw 0.390 nw 11.31 11.43 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO 0.097 0.390 - se 2.81 0.00 1.60 0.00 0 0 0 0 0 0 0 0 0 p C F 16B-38md 0.026 sw 0.75 1.37 0 0 0 0 0 0 0 0 0 0 22A-tpl 0.989 - 28.68 0.00 60 0 0 0 0 779 0 88 0 2524 0 0 6 c) AED excursion 0 2552 Envelope loss/gain 0 0 6430 74BO 12 a) Infiltration b) Room ventilation 0 0 920 244 0 0 0 0 13 Internal gains: Occupants @ 230 0 Appliances/other 0 0 0 p 1200 Subtotal (lines 6 to 13) 0 0 7350 8924 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads -0% 0% 0 0 0 0 20% 29% 7350 1454 8924 2632 Total room bad IAir required (cfm) 0 0 8804 11556 0 0 431 483 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed -P- wr10ftts43.1ft15 18:03:57 Sep ACZ`►. Right-Suite6 Universal 2019 19.0.12 RSU03398 2021- ...GY\A- MANUAL J\HOMECRETE-TROTTER 2021 SPLIT.rup Cale = MJ8 Front Door faces: N Page 10 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HOMECRETE-TROTTER Street: 4403 REDWOOD DR. City, State, Zip: FORT PIERCE, FL, Owner: HOMECRETE Design Location: FL. ST_LUCIE_CO_INTL Builder Name: HOMECRETE HOMES Permit Office: Permit Number: Jurisdiction: County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type44305.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=6.5 3840.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 465.00 ft2 4. Number of Bedrooms 3 c. N/A d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1869.0 sqft.) R= ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 2992 a• Under Attic (Vented) R=38.0 1869.00 ft2 Conditioned floor area below grade (ft2) 0 b. N/A c. N/A R= ft2 7. Windows(582.9 sqft.) Description Area 12. Ducts R= H2 R ft2 a. U-Factor: Dbl, U=0.33 148.00 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 150 SHGC: SHGC=0.26 b. Sup: Attic, Ret: Attic, AH: Attic 6 300 b. U-Factor: Dbl, U=0.31 SHGC: SHGC=0.28 142.92 ft2 13. Coolingsystems Efficiency c. U-Factor: Dbl, U=0.25 138.67 ft2 rkB17.1 a. Central Unit b. Central Unit 7.1 SEER:16.00 45.4 SEER:16.00 SHGC: SHGC=0.18 Area Weighted Average Overhang Depth: 5.412 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.245 a. Electric Heat Pump 16.3 HSPF:8.50 8. Skylights Area b. Electric Heat Pump 42.4 HSPF:9.00 C. U-Factor:(AVG) N/A ft2 SHGC(AVG): N/A 15. Hot water systems 9. Floor Types (1840.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1840.00 ft2 b. Conservation features EF: 0.930 b. NIA R- ft2 None c. NIA R= ft2 16. Credits Pstat Glass/Floor Area: 0.195 Total Proposed Modified Loads: 95.87 PASS Total Baseline Loads: 106.50 I hereby certify that the plans and sp cifications covered by this Review of the plans and S?,q�� calculation are in compliance wi the Florida En ( 9Y specifications covered by this O'eT14E Code. / calculation indicates compliance PREPARED BY: ?/� with the Florida Energy Code. ti .u;;,t�-•;; DATE: Before construction is completed this building will be inspected for Cc d 0A. compliance with Section 563.908 I hereby certify that this n d igned, is in compliance Florida Statutes. �.. with the Florida Energy �9 �,D� WE OWNER/A T' BUILDING OFFICIAL: DATE: DATE: - ..villwiaiice requires ceratication by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 9/15/2021 5:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 IAIDI IT 01 IRARA w w ' �+�+'•��•�rv1 vnC�,f�LIJ 1 Mr-rUK I PROJECT Title: HOMECRETE-TROTTER Bedrooms: 3 Building Type: User Address Type: Street Address Owner Name: HOMECRETE Conditioned Area: 2992 Lot # # of Units: 1 Total Stories: 2 Block/Subdivision: Builder Name: HOMECRETE HOMES Worst Case: No Rotate Angle: 0 PlatBook: Permit Office: Street: 4403 REDWOOD DR. Jurisdiction: Cross Ventilation: No County: St. Lucie Family Type: Detached Whole House Fan: No City, State, Zip: FORT PIERCE, New/Existing: New (From Plans) FL, Comment: CLIMATE Design Location TMY Site Design Temp Int Design Temp Heating Design Daily Temp 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 SYS 2 2337 22217 2 SYS 1 655 6550 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 LIVING ROOM 274 2740 No 0 3 1 No Yes Yes 2 LAUNDRY 63 630 No 0 1 No Yes Yes 3 1ST FLR BED 156 1560 No 2 1 No Yes Yes 4 WIC 1ST FLR BED 42 420 No 0 1 No Yes Yes 5 BATH 1 ST FLR BE 120 1200 No 0 1 No Yes Yes 6 BED 3 323 2907 No 1 1 No Yes Yes 7 WIC BED 3 56 504 No 0 1 No Yes Yes 8 BATH BED 3 86 770 No 0 1 No Yes Yes 9 TIOLET BATH 3 20 180 No 0 1 No Yes Yes 10 BED 2 225 2025 No 1 1 No Yes Yes 11 BATH BED 2 54 486 No 0 1 No Yes Yes 12 WIC BED 2 36 324 No 0 1 No Yes Yes 13 STAIRS 353 3173 No 0 1 No Yes Yes 14 DEN BATH 95 950 No 0 1 No Yes Yes 15 DEN 208 2080 No 0 1 No Yes Yes 16 WIC DEN 42 420 No 0 1 No Yes Yes 17 PANTRY 60 600 No 0 1 No Yes Yes 18 GRT RM KITCHEN 779 7790 No 0 1 No Yes Yes 9/15/2021 5:53 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-217190 IK1011T QI MR&M A -- ROME •+ I vvivJ1v1MM T lor1tk;KL15 I KEPORT FLOORS # Floor Type 1 Slab -On -Grade Edge Insulatio Space Perimeter Perimeter R-Value LIVING ROOM 42 ft 0 Area Joist R-Value 275 ft2 ____ Tile Wood Carpet 0 1 0 2 Slab -On -Grade Edge Insulatio LAUNDRY 15 ft 0 63 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulatio 1ST FLR BED 24 ft 0 156 ft2 ____ 0 1 0 4Slab-On-Grade Edge Insulatio WIC 1ST FLR BE 1 ft 0 42 ft2 0 1 0 5SIab-On-Grade Edge Insulatio BATH 1ST FLR B 24 ft 0 120 ft2 1 0 0 6 Slab -On -Grade Edge Insulatio DEN BATH 26.5 ft 0 95 ft2 _—_ 1 0 0 7 Slab -On -Grade Edge Insulatio DEN 1 ft 0 208 ft2 ____ 0 1 0 8Slab-On-Grade Edge Insulatio WIC DEN 6 ft 0 42 ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulatio PANTRY 1 ft 0 60 ft2 1 0 0 10SIab-On-Grade Edge Insulatio GRT RM KITCHE 88 ft 0 779 ft2 -__ 0.5 0.5 0 ROOF Roof # Type Materials Area Gable Area Roof Color Rad Barr Solar Absor. SA Emitt Tested Emitt Deck Tested Insul. Pitch (deg) 1 Hip Metal 2089 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1868 ft2 N N CEILING # Ceiling Type 1 Under Attic (Vented) Space LIVING ROOM R-Value 38 Ins Type Blown Area 275 ft2 Framing Frac 0.1 Truss Type Wood 2 Under Attic (Vented) 3 Under Attic (Vented) LAUNDRY 1 ST FLR BED 38 38 Blown Blown 63 ft2 156 ft2 0.1 0.1 Wood Wood 4 Under Attic (Vented) 5 Under Attic (Vented) WIC 1ST FLR BE BATH 1 ST FLR B 38 38 Blown Blown 42 ft2 120 ft2 0.1 0.1 Wood Wood 6 Under Attic (Vented) BED 3 38 Blown 323 ft2 0.1 Wood 7 Under Attic (Vented) WIC BED 3 38 Blown 56 ft2 0.1 Wood 8 Under Attic (Vented) 9 Under Attic (Vented) BATH BED 3 TIOLET BATH 3 38 38 Blown Blown 86 ft2 20 ft2 0.1 0.1 Wood Wood 10 Under Attic (Vented) BED 2 38 Blown 225 ft2 0.1 Wood 11 Under Attic (Vented) 12 Under Attic (Vented) 13 Under Attic (Vented) BATH BED 2 WIC BED 2 STAIRS 38 38 38 Blown Blown Blown 54 ft2 36 ft2 353 ft2 0.1 0.1 0.1 Wood Wood Wood 14 Under Attic (Vented) DEN BATH 38 Blown 60 ft2 0.1 Wood 9/15/2021 5:53 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 11U011T CI iRARew nv ... vvnnnrvt r vnCt.nL1.7 I Mt:VUK 1 WALLS Adjacent Space _ Cavity Width Height Sheathing Framing Solar Below 1 - 2 3 -4 _ 5 6 _ 7 - 8 9 _ 10 11 _ 12 13 14 _ 15 -16 17 _ 18 _ 19 20 _21 _22 _23 -24 _25 SE SW NW SE SW NE SE SW NE NE NE NE NE SW NW SE SW NW NE SE NE NE SW N NE Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Garage Exterior Concrete Block - Int InsWVING ROO Concrete Block - Int InsWVING ROO Concrete Block - Int InsdIST FLR BE Concrete Block - Int InsBATH 1 ST FL Concrete Block - Int InS@ATH 15T FL Concrete Block - Int Insul BED 3 Concrete Block - Int Insul BED 3 Concrete Block - Int Insul BED 3 Concrete Block - Int InsIHATH BED 3 Concrete Block - Int Ins0IIOLET BAT Concrete Block - Int Insul BED 2 Concrete Block - Int InS&IATH BED 2 Concrete Block - Int Insul STAIRS Concrete Block - Int Insul STAIRS Concrete Block - Int Insul STAIRS Concrete Block - Int InsuDEN BATH Concrete Block - Int InsuDEN BATH Concrete Block - Int InsuDEN BATH Concrete Block - Int Insul DEN Concrete Block - Int Insul DEN Concrete Block - Int InsuIWIC DEN Concrete Block - Int InsORT RM KIT Concrete Block - Int Ins13RT RM KIT Frame - Wood LIVING ROO Concrete Block - Int Ins&RT RM KIT 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 6.5 11 6.5 34 15 11 12 12 18 20 26 8 4 16 6 18 40 19 12 8 7 14 16 6 16 45 46.5 16 5 1 6 11 11 3 5 11 7 4 2 5 3 10 0 11 1 0 0 8 5 3 2 3 9 4 9 4 10 0 9 4 9 4 9 4 9 4 9 4 9 4 9 4 9 4 9 4 9 4 9 4 10 0 9 4 9 4 10 0 9 4 9 4 9 4 9 4 9 4 10 9 4 321.2 ft2 140.8 ft2 115.0 ft2 120.6 ft2 120.6 ft2 170.3 ft2 190.6 ft2 251.2 ft2 80.1 ft2 40.4 ft2 150.9 ft2 59.9 ft2 170.3 ft2 381.1 ft2 190.0 ft2 120.6 ft2 75.4 ft2 70.0 ft2 130.7 ft2 155.6 ft2 59.9 ft2 151.7 ft2 421.6 ft2 465.0 ft2 151.7 ft2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.23 0 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width In Height Ft In Area 1 NW Insulated DEN BATH None .39 3 4 6 8 22.2 ft2 2 N Wood LIVING ROO None .39 2.8 8 22.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / V/ Wall # Ornt ID Frame Panes NFRC U-Factor SHGC 1 SE 1 Metal Double (Tinted) Yes 0.33 0.26 2 SW 2 Metal Double (Tinted) Yes 0.25 0.18 3 SW 2 Metal Double (Tinted) Yes 0.26 0.29 Imp N N N Area 50.0 ft2 24.0 ft2 5.0 ft2 Overhang Depth Separation 2 ft 0 in 1 ft 0 in 2 ft 0 in 1 ft 0 in 2 ft 0 in 1 ft 0 in Int Shade None None None Screening None None None 4 NW 3 Metal Double (Tinted) Yes 0.31 5 SW 5 Metal Double (Tinted) Yes 0.26 6 NE 6 Metal Double (Tinted) Yes 0.32 7 SE 7 Metal Double (Tinted) Yes 0.26 8 SW 8 Metal Double (Tinted) Yes 0.25 0.28 0.29 0.25 0.29 0.18 N N N N N 32.1 ft2 5.0 ft2 30.8 ft2 5.0 ft2 45.3 ft2 2 ft 0 in 2 ft 0 in 2 ft 0 in 2 ft 0 in 8 ft 0 in 1 ft 0 in 1 ft 0 in 1 ft 0 in 1 ft 0 in 1 ft 0 in None None None None None None None None None None 9/15/2021 5:63 PM EnergyGaugee USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 R405-2020 INPUT SUMMARY CHECKLIST WINDOWS / Wall # Ornt ID Frame Panes NFRC U-Factor, SHGC Imp Area Deptherhang Separation Int Shade 9 SW 8 Metal Double (Tinted) Yes 0.31 0.28 N 15.8 ft2 8 ft 0 in 1 ft 0 in None 10 NE 9 Metal Double (Tinted) Yes 0.26 0.29 N 5.0 ft2 2 ft 0 in 1 ft 0 in None 11 NE 11 Metal Double (Tinted) Yes 0.32 0.25 N 30.8 ft2 2 ft 0 in 1 ft 0 in None 12 NE 12 Metal Double (Tinted) Yes 0.26 0.29 N 5.0 ft2 2 ft 0 in 1 ft 0 in None 13 NE 13 Metal Double (Tinted) Yes 0.26 0.29 N 5.0 ft' 2 ft 0 in 1 ft 0 in None 14 SW 14 Metal Double (Tinted) Yes 0.25 0.18 N 45.3 ft2 8 ft 0 in 1 ft 0 in None 15 SW 14 Metal Double (Tinted) Yes 0.31 0.28 N 32.1 ft2 8 ft 0 in 1 ft 0 in None 16 NE 19 Metal Double (Tinted) Yes 0.32 0.25 N 30.8 ft2 2 ft 0 in 12 ft 0 in None 17 SE 20 Metal Double (Tinted) Yes 0.31 0.28 N 30.8 ft2 2 ft 0 in 12 ft 0 in None 18 NE 25 Metal Double (Tinted) Yes 0.25 0.18 N 24.0 ft2 10 ft 0 in 1 ft 0 in None 19 NE 22 Metal Double (Tinted) Yes 0.32 0.25 N 30.8 ft2 8 ft 0 in 1 ft 0 in None 20 SW 23 Metal Double (Tinted) Yes 0.31 0.28 N 32.1 ft2 8 ft 0 in 1 ft 0 in None 21 SW 23 Metal Double (Tinted) Yes 0.33 0.26 N 98.0 ft2 8 ft 0 in 1 ft 0 in None GARAGE # 1 Floor Area 455 ft2 Ceiling Area 455 ft2 Exposed Wall Perimeter Avg Wall Height Exposed Wall Insulation 42 ft loft 1 INFILTRATION # Scope 1 Wholehouse Method Proposed ACH(50) SLA .000427 CFM 50 ELA EgLA ACH ACH 50 3355.2 184.08 345.58 .1794 7 HEATING SYSTEM V # System Type 1 Electric Heat Pump/ 2 Electric Heat Pump/ # System Typf 1 Central Unit/ 2 Central Unit/ e None None None None None None None None None None None None None cinuancy capacity Block Ducts Split Singl HSPF:8.5 16.3 kBtu/hr 2 sys#1 Split Singl HSPF:9 42.4 kBtu/hr 1 sys#2 COOLING SYSTEM Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts Split Sing[ SEER: 16 17.1 kBtu/hr cfm 0.84 2 sys#1 Split Singl SEER: 16 45.4 kBtu/hr cfm 0.85 1 sys#2 HOT WATER SYSTEM - -- •,� -.yww Location EF Cap Use SetPnt Electric None Garage 0.93 50 gal 60.9 gal 120 deg Conservation None 9/15/2021 5:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 KM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model Collector Storage # Area Volume FEF — None None ft' DUCTS / --- Supply ---- V # Location R-Value --- Return --- Air Area Location Area Leakage Type Handler CFM 25 CFM25 TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 Attic 6 150 ft2 Attic 150 ft2 Default Leakage Attic 300 ft2 Attic 150 ft2 Default Leakage Attic (Default) (Default) (Default) (Default) 1 1 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Heating Venting j Jan X] Jan j Jan [r ]] Feb (Xj Feb [tt[[ 1] Feb [ jj Mar [X] Mar Mar Apr Apr [ ] Ma� May Jun jXj Jun Jul rj Jul Aug rj Aug Sep jXj Sep Oct WOct v Nov HNo Dec [[XJJ [X] Apr [[ ]] Ma Jun Jul Aug Sep Oct Nov Dec Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 80 80 80 80 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 PM 68 66 68 66 Mass Type Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft, Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Area 0 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 ft2 66 68 68 MASS Thickness��� Oft ft ft ft ft ft ft ft ft ft ft ft ft ft ft ft ft 68 Furniture Fraction 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 68 68 LIVING ROOM LAUNDRY 13T FLR BED WIC 1ST FLR BED BATH 1ST FLR BE BED 3 WIC BED 3 BATH BED 3 TIOLET BATH 3 BED 2 BATH BED 2 WIC BED 2 STAIRS DEN BATH DEN WIC DEN PANTRY GRT RM KITCHEN 66 9/15/2021 5:53 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The lower the EnergyPerformance Index, the more efficient the home. 4403 REDWOOD DR., FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation yP Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=6.5 3840.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 465.00 ft2 4. Number of Bedrooms 3 c. N/A d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level R= ft2 Insulation Area 6. Conditioned floor area (ft2) 2992 a. Under Attic (Vented) R=38.0 1869.00 ftz 7. Windows- Description Area b. N/A c. N/A R= ft2 R= ft2 a. U-Factor: Dbl, U=0.33 148.00 ft2 12. Ducts, location & insulation level R ftZ SHGC: SHGC=0.26 a. Sup: Attic, Ret: Attic, AH: Attic 6 150 b. U-Factor: Dbl, U=0.31 142.92 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 300 SHGC: SHGC=0.28 c. U-Factor: Dbl, U=0.25 138.67 ft2a. 13. Coolingsystems y kB17.1 Efficiency SHGC: SHGC=0.18 r Central Unit b. Central Unit 7.1 SEER:16.00 d. U-Factor: other (see details) 153.33 ft2 45.4 SEER:16.00 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 5.412 ft. a. Electric Heat Pump 16.3 HSPF:8.50 Area Weighted Average SHGC: 0.245 b. Electric Heat Pump 42.4 HSPF:9.00 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 50 gallons SHGC(AVG): N/A EF:0.93 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1840.00 ft2 None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before fi I i pection. O herwise, a new EPL Display Card will be completed based on installed Co a lia f tures. Builder Signature: Date: Address of New Ho (�,. (p ?; r,1r,T� �j� City/FL ZipTi2IE�C� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/15/2021 5:53 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1