HomeMy WebLinkAbout56-SF-2241181 FINALSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICANT: Rodney Hall Concrete Construction, Inc
AGENT: Rodney Hall
PROPERTY ADDRESS: 11771 Appaloosa Ct Fort Pierce, FL 34987
APPLICATION # : AP 1630453
PERMIT #:56-SF-2241181
DOCUMENT # : FI 1684397
DATE PAID.02/15/2021
FEE PAID:545.00
RECEIPT #:56-PID-4886003
LOT: 23
SUBDIVISION:
BLOCK:
Pony Pines ID#: 3309-605-0026-000-2
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH
STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ]
[01]
TANK SIZE [1] 1050.00 [21
[ ]
[271
SURFACE WATER
FT
[ ]
[021
TANK MATERIAL Polypropylene
[ ]
[28]
DITCHES
FT
[ ]
[03]
OUTLET DEVICE
[ ]
[29]
PRIVATE WELLS 100
FT
[ ]
[04]
MULTI -CHAMBERED [LIJ N ]
[ ]
[301
PUBLIC WELLS
FT
[ ]
(05)
OUTLET FILTER Polylok PL-68
[ ]
[31]
IRRIGATION WELLS
FT
[ ]
[06]
LEGEND 1. 70-156-10DC3 2.
[ ]
[ 32 ]
POTABLE WATER 65
FT
[ ]
[07]
WATERTIGHT
[ ]
[33]
BUILDING FOUNDATIONS 7
FT
[ ]
[081
LEVEL
[ ]
[34]
PROPERTY LINES 74
FT
[ ]
[091
DEPTH TO LID
[ ]
[351
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ]
[10]
AREA [1] 679.2 [2] SQFT
[ ]
[36]
DRAINFIELD COVER
[ ]
[111
DISTRIBUTION BOX HEADER X
[ ]
[371
SHOULDERS
[ ]
[12]
NUMBER OF DRAINLINES 1. 8•00 2.
[ ]
[38]
SLOPES
[ ]
[13]
DRAINLINE SEPARATION
[ ]
[39]
STABILIZATION
[ ]
[141
DRAINLINE SLOPE
[ ]
(15]
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ]
[161
ELEVATION [ AHOVE / BELOW ]BM 22.00
[ ]
(401
UNOBSTRUCTED AREA
[ ]
[17]
SYSTEM LOCATION
[ ]
[41]
STORMWATER RUNOFF
[ ]
[18]
DOSING PUMPS
[ ]
(421
ALARMS
[ ]
[19]
AGGREGATE SIZE
[ ]
[43]
MAINTENANCE AGREEMENT
[ ]
[201
AGGREGATE EXCESSIVE FINES
[ ]
(441
BUILDING AREA
[ ]
[211
AGGREGATE DEPTH
[ ]
[45]
46
LOCATION CONFORMS WITH SITE PLAN
FINAL SITE GRADING
FILL
/ EXCAVATION MATERIAL
[ ] [ ]
[ ]
[221
FILL AMOUNT
[ ] [47]
CONTRACTOR (All Contractors Services DB
[ ]
[23]
FILL TEXTURE
[ ] [48]
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ]
[241
EXCAVATION DEPTH
ABANDONMENT
[ ]
[25]
AREA REPLACED
[ ] [49]
TANK PUMPED
[ ]
[26]
REPLACEMENT MATERIAL
[ ] [501
TANK CRUSHED & FILLED
Comments: Comments are on page 2.
CONSTRUCTION [ APPROVED /
St. Lucie CHD
DISAPPROVED ] ' Environmental Specialist III Bria Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED ] p �_ %— �� St. Lucie cHD
Environmental Specialist I Il�fatthe jan orida Department of H
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
EH Database v 1.0.1 AP1630453 EID2241181
DATE: 08/27/2021
DATE: 11 /23/2021
Page 2 of 3
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION #:AP1630453
PERMIT #:56-SF-2241181
DOCUMENT # : FI 1684397
DATE PAID.02/15/2021
FEE PAID :545.00
RECEIPT #:56-PID-4886003
The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400
gpd.
New ST, filter, and 4x8+4x7 long BED DF installed. No violations, system ok to cover, contractor notified onsite. Site wet at time
of inspection, but not holding water. Needs final inspection for filled system, gutters, and final site grading.
Final inspection completed. Filled system checked, gutters added, and final site grading completed
Final inspection approved. Emailed copy to building department and contractor.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1630453 EID2241181