HomeMy WebLinkAboutFormboardFPKD
LS 4286
0.26' N
0 R=120.00'
Delta=12' 17' 19
Length=25.74
FPKD
LS 4286
0.26' N
FPKW
a
LEGAL DESCRIPTION
Unit K, HARBOUR RIDGE, PLAT NO. 21, according to the Plat
thereof, as recorded in Plat Book 32, Pages 22 and 22A, Public
Records of St. Lucie County, Florida.
V
!v cn N
FPKD � k�
PRO
IL
q 5�
®fir
t 15.0fAOOr
No
0
19
N32�3$50'SOpE � ,.- '"' s51 � , y.\1•$ o LA�
7.7' a+
o -�
c
20' 44.2'r-
f ` A o
CL
1
� 6
w iQ
/ ro
/ IFooterl {TYP) Il L
--
�c
SURVEYOR'S REPORT
1 This Survey shall not be valid unless sealed with on
embossed Surveyor's Seal.
2 No underground improvements have been located
as part of this Survey.
3 The last field date of this Survey was: 3.26.2019.
4 This Survey was prepared using the Plat of Record,
no search of the public records was performed by
this office.
5 This Survey shown hereon was prepared in
accordance with the Standards of the practice of
Surveying and Mapping as defined in
5J— 1 7.050-052FAC.
6 By acceptance of this survey all parties agree that
the signing surveyor's liability is limited to the
amount paid for said Survey.
7 Bearings have been based on the North Line of
the Subject Property as shown hereon. All other
bearings are relative thereto.
8 Parcel/Lot line locations have been based on found
survey control along the center line and/or right of
way line of NW Mariner Court.
9 LEFT BLANK.
10 The Legal Description shown hereon was provided
by the client and/or his/her representatives.
11 No ownership of fence lines has been determined
as part of this Survey.
12 Off set calls to found survey control are relative
to the nearest property corner, intersection of lines,
point of curvatures (PC), point of reverse curvatures
(PRC) or other identifiable point.
13 Compliance with local zoning requirements and or
with requirements set forth by other State, Public,
and/or Private entities has not been verified as part
of this Survey.
14 Elevations shown hereon are in accordance with
the North American Vertical Datum of 1988.
,gyp FEMA Flood Zone data shown here on is based on the visual inspection of
C71 o I the digital Flood Hazardous Maps provided by the Federal Emergency
i Management Agency (FEMA) and is limited to the accuracy of such maps.
..� Flood Zone: X Community #: 120285, Panel: 0402, Suffix: K, Date: 2.19.2020
w
i .77'
�-
Qrn o r`� c;,� stemwall (P)
r+ Q+ tT tD f
Line tot El. 14.26 i U(?
Pour
t
r \\ stemwall Formed t 1 1.52'
20' Setback 4 Cf N Cn
Iu
i
I°�* \\ s 1
__- _ FIR
,r �,�. , � �- �..._.� w LS 4676
to 0
r
r ,
213.46'(F)
_._._ S44041 co L
FIR 213.57Di 3i
LS 4676 S44'41'13"W r,r.ovi
.._.__ _ _ sue°
Tract OVi loge) 12
(Osprey No, 5E
Harbour Ridge_
p.B.28 Pp-1 -1
A Condom with the
Finished Floor Elevations eing with
Various Garage Elevation
lowest
PREPARED FOR:
John and Margaret Lauletta
Prepared By: Regina C. Karner, PSM#4363
Kamer Surveying, Inc. LB#7357
Prepared For:
Jahn & Margaret Lauletta
LEGEND
C — Concrete
CIE — Covered Entry
CAC — Concrete Pad with Air Conditioning
CS — Catch Basin
CBS — Concrete Block Structure
CUP — Corrugated Metal Pippee
CPE — Concrete Pad with Pal Equipment
cry — Coble TV Box
FFE — Finished noor Elevation
CV — Water Gate Valve
HYD — Fire Hydrant
OIL — Overhead Utility Line
PP — Power Pole
SSMH — Sanitary Sewer Manhole
TCB — Telephone Communications Box
UB — Utility Box
WM —Water Motor
Site Plan Legend:
X0.00 — Denotes existing Elevations (NAVD)
NAVD — North American Vertical Datum
KARNER SURVEYING, INC. i
Residential & Commercial Surveying Services
2740 SW Martin Downs Blvd.#333, Palm City, F1.34990
Phone: (772)288 7206 Fax:(772)223 8181
NWWSARNERSURVEYINGINC.COM knrnarbcnmcncs not ` w a.!= Vt
LEGEND
FCM — Found 4 x4 Concrete Monument
RP — Found It' Iron Pipe
nPC — Found Iron Pipe with Cap
nR — Found 15 Iron Rod
nRC — Found 15 Iron Rod with Cap
SIRC — Set /5 Iron Rod with Cop '1B17357'
FiPC — Found 112' Iron Pipe with Cap
IN — Found Moog Nail
FWD — Found Mbg Nail with Disk
FN — Found Nail
FNTt — Found Nail with Tin Fab
FPK — Found PK Nail
FPKD — Found PK Nail with Disk
FRRS — Found Rail Road Spike
/CO — In Pavement Cut Out
4421 21
Pro Building Layout
7202
Ad.FFE and adds dimensions
10.25.21
StomwalVFootor Tie in
t nttet
Bo ue c `off xy- Survey
1•s�• �saar
1 of 1
FA,- Iva,
9a1?-fe -