HomeMy WebLinkAboutTruss Engineering4451 ST. LUCIE BLVD FORT PIERCE, FL 34946-,;� PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com RECEIVED NOV 17 2021 St. Lucie County Permitting TRUSS ENGINEERING BUILDER: HABITAT SLC _ PROJECT: SALERNO RD COUNTY: EXEMPT LOT/BLK/MODEL: 10268 SALERNO JOB#: 86250 MASTERM CHHS3B OPTIONS: NO OPTIONS C A-1 ROOF TRUSSES A FLORIDA CORPORATION Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. RE, -'Job CHHS3B JOB #86250 Site Information: Customer Info: HABITAT ST. LUCIE COUNTY Project Name: SCATTERED LOTS Lot/Block: Model: THREE BEDROOM Address: Subdivision: City: County: St Lucie A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce, FL 34946 State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: ` General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 7th Ed. 2020 Res. / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-16 Wind Speed: 160 , Roof Load: 40.0 psf Floor Load: 0.0 psf This package includes 30 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seq # Truss Name Date No. Seq # Truss Name Date No. Seq # Truss Name Date 1 2645 A01 2/9121 13 2651 B01 2/9121 25 2601 CJ7 2/9/21 2 2581 A02 2/9/21 14 2592 - B02 2/9/21 26 2606 HJ5 2/9/21 3 2582 A03 2/9121 1 15 2593 B03 2/9/21 27 2607 HJ8 2/9/21 4 2583 A04 2/9/21 16 2594 1304� 2/9/21 28 2603 J7 2/9/21 5 2641 A05 2/9/21 17 2609 B05 2l9/21 29 2604 J8 2/9/21 6 2638 A06 2/9/21 18 2595 B06 2/9/21 30 2606 J813 2/9/21 7 2616 A07 2/9/21 19 2596 B07 2/9/21 31 STDL01 STD. DETAIL 2/9/21 8 2613 A08 2/9/21 20 2597 B08 2/9/21 32 STDL02 STD. DETAIL 2/9/21 9 2621 A09 2/9121 21 2648 B09 2/9/21 33 STDL03 STD. DETAIL 2/9/21 10 2635 A10 2/9/21 22 2598 CA 2/9/21 34 STDL04 STD. DETAIL 2/9/21 11 2629 All 2/9121 23 2599 CM 2/9/21 35 STDL05 STD. DETAIL 219/21 12 2632 1 Al2 2/9121, 24 2600 1 CJ5 219/21 30, STDL0.6. STD. DETAIL 2/9/21 The truss drawing(s) referenced have been prepared byAlpine Engineered Products, Inc. under mydirectsupervision basedon he parameters provided byXTRoofTnisses, Ltd. Truss Design Engineer's Name: Rama Pranav Kristam My license renewal date for the state of Florida is February 28,2021. �1 NOTE:The seal on these drawings indicate acceptance of professionalengineeting 11 �-'+r responsbTitysolelyforthetrusscomponentsshown. ,Y'�-* Thesultabilltyand use of components forany particularbuilding is the responsibility ofthe building designer, perMSVrPI-1 Sec. 2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction ' documents (also referred to at times as'Structural Engineering Documents) provided by the Bui�dmg r E Designer indicating the natureand characterof the work. The design criteria therein have been transferred to Rama Pranav Kristam PE by [A1 Roof Trusses or specific location]. These TDDs (also referred to at times as'Structural Delegated' Engineering Documents) are specialty structural component designs and may be part of the pro�eat's { • +'+ �•�" ' .. deferred orphased submittals. AsaTruss Design Engineer (Iz., specialty ' `'��.��3y,.•'w' ��"' Engineer), the seal here and on the TDD represents an acceptance of professional engineering, responsibilityforthedesignofthesingleTrussdepictedontheTDDonly.TheBuildingDestgnetis responsible forand shall coordinate and review the TDDs for compatibility with theirwritten engineering requirements. Please review all TDDs and all related notes Ryan;Bays, .PE 4451I.S.f.Luck Blvd.8uite;201 Fort Pierce, FL 34946 Ryan by Ryan M Bays Pierce, Page 1 of 2 A-1 ROOF TRUSSES A FLORIDA CORPORATION RE: Job CHHS313 No. Seq # Truss Name Date 37 STDL07 STD. DETAIL 219/21 38 STDL08 STD. DETAIL 2/9/21 39 STDL09 STD. DETAIL 2/9/21 40 STDL10 STD. DETAIL 219/21 41 STDL11 STD. DETAIL 219121 42 STDL12 STD. DETAIL 2/9/21 43 STDL13 STD. DETAIL 2/9121 44 STDL14 STD. DETAIL 219/21 45 STDL15 STD. DETAIL 2/9/21 46 STDL16 STD. DETAIL 219/21 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 y These truss designs rely on lumber values established by others. Page 2 of 2 Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fart Pierce, FL 34946 Job Truss Truss Type Qty Ply 02/09/2021 CHHS3B I A01 I HIPS 11 I 1 2645 16'4" / 11'8" 16'4" =5X6 G H _ X I T ,2 4 p 3X6 F 4X6 �3X4E J K .3X6 1.5X4 D to o4X4 C (a) (a L-3X4 4X6(C6 B spa -_ =3X6(C6) S R Q P O 1113 N =-3X4 3X4 ==5X6 =3X8 =4X12 =3X6 SEAj PLATE REQ. SEAT PLATE REQ. L16 364" 7W �{ �- 2'6" 1 44'4" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.0( GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 :SP 2400f-2.OE + SP M-31:; T2 2x4 SP M-30; T3,T4 2x4 SP #2; Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP M-30; B3 2x4 SP 2400f-2.0E + SP M-31; Webs: 2x4 SP #3; W7 2x6 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Rt Slider: 2x6 SP #2; block length = 2.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 16.33 28.00 BC 75 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with.42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Code / Misc Criteria Code:FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes AFT/RT:10(0)/10(10) Plate Type(s): WAVE T M=3X6(C6) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udefl L/# Gravity Non -Gravity VERT(LL): 0.145 L 368 360 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.312 L 171 240 B 1686 /- P /1060 /783 /178 HORZ(LL): -0.045 L - - N 2107 P /- 11390 /899 /- HORZ(TL): 0.076 L - - Wind reactions, based on MWFRS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.681 N Brg Width = 8.0 Min Req = 1.7 Max BC CSI: 0.773 Bearings B & N are a rigid surface. Max Web CSI: 0.832 Bearings B & N require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:241.5lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.01.01A.0724.12 B - C" 383 -937 G - H 1849 -2088 A- B 52 0 H- I 1488 -1539 C - D 1754 -2437 I - J 1461 -1689 D - E 1980 -2639 J - K 1437 -1704 E - F 1840 -2270 K - L 896 -1187 F - G 1861 - 2249 L - M 863 -1059 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - S 2220 -1485 P - O 1079 - 725 S - R 2535 -1795 O - N 1079 - 725 R.- Q 2534 -1796 N - L 1178 -779 Q - P 1980 -1491 L - M 1083 - 811 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B'_ C 2400 - 2442 Q - H 344 - 99 D - S 449 - 453 H - P 825 - 691 S - E 449 -222 P -1 218 -47 E - Q 424 - 544 P - K 2069 -1864 G - Q 372 - 88 K - N 1918 -1898 "WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and theSpecialtyEngineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. Convrinht 4 2016 A-1 Roof Tmcwa - Renrod.,oti- of this domrment. in env form. Is nmhihhed vothout the written nerrniseinn of A-1 Roof Tnr. oec. Job Truss Truss Type Qty Ply 02/09/2021 CHHS313 I A02 HIPS 11 1 2581 18'4" i7,8" oa 5X8 G =5X6 H 18'4" T 12 _ 4 3X4 F I sz X _X6 � rn �3X4D 3X6E (a) K1112X4 _ (a) C6) 3(C 4X6(C6 t -lsps• T S R Q P O N M= X6 S�E1Aj,PLATE�REQ. �— 2'6" Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 1111.5X3 =3X4 =5X6 =3X4 =3X8 =3X6 Wind Criteria Wind Std: ASCE 7-16 Speed: 1160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.01 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.OE + SP M-31; T2 2x4 SP M-30; Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP #2; B3 2x4 SP M-30; Webs: 2x4 SP #3; W8 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 18.33 26.00 BC 72 0.00 44.33 Apply purlins to any chords above.or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. SEAT PLATE REQ. 35'4" 1 7'6" —� 44'4" _I 3X6(A1) Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.147 F 999 360 Loc R+ - / R- / Rh / Rw / U / RL Rep Factors Used: Yes VERT(CL): 0.306 F 999 240 T 1674 /- /- /1049 /777 /196 FT/RT:10(0)/10(10) HORZ(LL): 0.034 M - - M 2121 /- /- /1388 1887 /- Plate Type(s): HORZ(TL): 0.075 M - Wind reactions based on MWFRS WAVE Creep Factor: 2.0 T Big Width = 8.0 Min Req = 1.5 Max TC CSI: 0.999 M Brg Width = 8.0 Min Req = 2.5 Max BC CSI: 0.985 Bearings T & M are a rigid surface. Bearings T & M require a seat plate. Max Web CSI: 0.738 Maximum Top Chord Forces Per Ply (Ibs) t Wgt:233.1 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 20.01.01A.0724.12 B - C 477 -1256 G - H 1449 -1528 A- B 52 0 H- I 1433 -1659 C - D 1537 -2346 I - J 867 -1098 D - E 1805 -2615 J - K 860 -1110 E - F 1817 -2575 K - L 870 -1224 F - G 1672 -2010 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp T - B 1209 - 360 P - O 1854 -1173 T - S 2173 -1330 O - N 988 - 606 S - R 2196 -1352 N - M 988 - 606 R - Q 2337 -1529 M - L 1216 - 759 Q - P 2336 -1529 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - C 1134 -1271 G - O 530 -498 S - D 603 - 575 O - H 262 - 75 D - R 450 -408 0-1 822 - 719 R- F 353 0 I- M 1921 - 2078 F - P, 513 - 630 M - K 578 - 452 G - P 530 -226 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. - responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1. Cnnvrinht 0 2016 A-1 Ronf T.,.-- Renrnduntinn of this dr-ment. in env form. is nmhihited withnut the written permission of A-1 Rnof Tnrss Job Truss CHHS3B A03 r 20'4" Truss Type Qty Ply 02/09/2021 HIPS 11 11 -}� 3'8" 20'4" =5X6 =6X6 G H T 12 4 r,� o0a3X4F 1Z—Z3X4 g J ZZ 3X6 4X6 E K__ _ o3X4D (a) 3�(C6) C =4X6(C6 L - sps• T S R Q P O N 1113 M 1111.5X4 =3X4 =5X6 =3X4 =3X4 =3X6 =4X4 SEAT, PLATE REQ. 2,6e '1 V Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 i Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.01 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE + SP M-31; T3 2x4 SP #2; Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP M-30; B3 2x4 SP #2; Webs: 2x4 SP #3; W8 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 20.33 24.00 BC 61 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. SEAT PLATE REQ. 35'4" i7'6" Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE , ft 44'4" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.276 Q 999 36 VERT(CL): 0.654 Q 636 24 HORZ(LL): 0.063 G - - HORZ(TL): 0.151 G Creep Factor: 2.0 Max TC CSI: 0.817 Maz BC CSI: 0.995 Max Web CSI: 0.784 Wgt: 230.3 Ibs VIEW Ver: 20.01.01A.0724.12 2582 3X6(A1) ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL U 1686 /- /- /1044 1782 /214 M 2107 /- /- /1365 /879 /- Wind reactions based on MWFRS U Brg Width = 8.0 Min Req = 1.5 M Brg Width = 8.0 Min Req = 2.5 Bearings U & M are a rigid surface. Bearings U & M require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 521 -1332 G - H 1425 -1603 A- B 52 0 H- 1 1402 -1745 C - D 1439 - 2339 I - J 565 - 676 D - E 1759 - 2705 J - K 557 - 741 E - F 1776 - 2655 K - L 904 -1135 F - G 1446 -1777 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp.' U - B 1282 -400 Q - P 1603 - 893 U - T 2175 -1251 P - O 1271 - 754 T - S 2201 -1276 O - N 1271 - 754 S - R 2326 -1428 N - M 1055 - 697 R - Q 2326 -1428 M - L 1154 - 778 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - C 992 -1183 H - P 192 - 52 T - D 579 - 576 P -1 725 - 517 D - S 477 - 369 I - N 1234 -1224 S - F 514 -42 N - K 1432 -981 F - Q 822 - 959 K - M 1600 -1920 G-Q 421 -218 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. ; Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In,the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon inventing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-I. Cnnvriaht* 2016 A-1 Rnof Tnrzse_c — Renrnduotinn of this dome—rit. in anv form. is nrohihited without tha written narmicsinn nfA-1 Rnnf Tnn—s. Job Truss CHHS3B A04 Truss Type Qty I Ply HIPS 1 1 02/09/2021 2583 tl [— 2,6" S`F2T, PLN ATE REQ. 22' r_ 22' 1111.5X3 =3X4 =5X6 =3xb =3X6 =4X4 Loading Criteria (psf) Wind Criteria - TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.01 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE + SP M-31; T3 2x4 SP #2; Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP M-30; B3 2x4 SP #2; Webs: 2x4 SP #3; W8 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Puriins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 58 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. J L SEAT PLATE REQ. 35'4" i 7'6" -� Code / Misc Criteria Code: FBC 7th Ed: 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity VERT(LL): 0.150 Q 999 360 Loc R+ / R- / Rh / Rw / U / RL S 1686 /- /- /1032 /782 /229 VERT(CL): 0.310 Q 999 240 HORZ(LL): 0.031 M - - L 2107 /- A /1350 /879 /- HORZ(TL): 0.067 M - - Wind reactions based on MWFRS Creep Factor:10 S Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.631 L Brg Width = 8.0 Min Req = 2.5 Max BC CSI: 0.994 Bearings S & L are a rigid surface. Bearings S & L require a seat plate. Max Web CSI: 0.778 Maximum Top Chord Forces Per Ply (Ibs) Wgt:230.3lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.01.01A.0724.12 B - C 576 -1470 F - G 1266 -1676 A-B 52 0 G-H 1241 -1671 C - D 1422 - 2435 H - I 658 - 931 D - E 1578 - 2594 I - J 645 - 995 E - F 1599 - 2550 J - K 915 -1147 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. S - B 1414 -452 O - N 1400 -753 S - R 2272 -1241 N - M 1400 - 753 R - Q 2292 -1261 M - L 1064 - 708 Q - P 2215 -1249 L - K 1160 - 789 P - O 2214 -1250 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - C 917 -1139 G - O 606 - 307 R - D 529 -475 O - H 302 -259 D - Q 268 - 230 H - M 1034 -1031 Q - F 488 -16 M - J 1585 -1080 F - O 774 - 881 J - L 1633 -1960 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1- The approval of the TDD and any field 4451 St. Lucie Blvd, Suite 201 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer, of any building. All capitalized terms are as defined In TPI-11. ` C owiaht Q 2016 A-1 Ronf Tniss".s — Renroduc Linn of this d—iment, in anv form. is nrohibitsd without the written nermicsinn of A-1 Roof Tmace_c. Job Truss CHHS3B A05 t , Truss Type HIPS Qty Ply 02/09/2021 1 1 2641 r 20'6" %T PLATE REQ. =3X4 =H0308 Loading Criteria (psq Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.0E + SP M-31; T3 2x4 SP #2; Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:; B2 2x4 SP M-30; B3 2x4 SP #2; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 2.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 20.50 23.83 BC 61 0.00 44.33 Apply purins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. - 3'4" sa5X6 =6X6 F G =3X4 =3X4 35'4" Code / Misc Criteria Code:FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS 44'4" 20'6" =3X6 =;6(4 1113X6` Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.303 P 999 36( VERT(CL): 0.694 P 600 24( HORZ(LL): 0.053 F - - HORZ(TL): 0.130 F - Creep Factor: 2.0 Max TC CSI: 0.873 Max BC CSI: 0.994 Max Web CSI: 0.793 Wgt: 219.1 Ibs VIEW Ver: 20.01.01A.0724.12 SEAT PLATE REQ. T6" -{ =3X6(A1) ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL S 1520 /- P /880 /684 /183 L 2112 P P /1361 /888 P Wind reactions based on MWFRS S Brg Width = 8.0. Min Req = 1.5 L Brg Width = 8.0 Min Req = 2.5 Bearings S & L are a rigid surface. Bearings S & L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 149 - 655 F - G 1477 -1628 B - C 1989 -2698 G - H 1456 -1772 C - D 1881 -2611 H -1 577 - 731 D - E 1892 - 2552 I - J 565 - 773 E - F 1501 -1806 J - K 899 -1130 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. S - R 2461 -1681 O - N 1301 - 795 A - S 666 -136 N - M 1301 - 795 R - Q 2315 -1520 M - L 1085 - 726 Q - P 2315 -1520 L - K 1145 - 773 P - O 1628 - 941 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. S - B 2000 -2270 G - O 183 -52 C - R 233 - 54 O - H 720 - 505 R - E 381 - 34 H - M 1242 -1220 E - P 811 - 908 M - J 1485 -1031 F - P 462 -271 J - L 1613 -1923 '-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the )j g1231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvdnht Q 2016 A-1 Roof To,-- — Renmduc:tinn of this dnatment. in env fern. is nrnhihtted Wfhnut the written nermicsion of A-1 Roof Tnicce_s. Job Truss CHHS3B A06 Truss Type HIPS 1ty 1y 102/09/2021 1 it 2638 A SEAT PLATE REQ. Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 18'6" 1 7'4" e5X8 F 5X6 G 18'6" 1 =3X4 =4X6 =3X4 =3X8 =3X6 -'^� Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height:`25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.01 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.0E + SP M-31; T5 2x4 SP M-30; Bot chord: 2x4 SP M-30; 131 2x4 SP 2400f-2.OE + SP M-31; Webs: 2x4 SP #3; W6 2x6 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Bracing (a) Continuous lateral restraint equally spaced on member.' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 18.50 25.83 BC 75 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 35'4" Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE SEAT PLATE REQ. 44'4" (=3X6(A1) 7,6" Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl L/# Gravity Non -Gravity. VERT(LL): 0.190 E 999 360 Lot- R+ / R- / Rh / Rw / U / RL VERT(CL): 0.400 E 999 240 R 1508 /- /- /885 /679 /165 HORZ(LL): -0.055 B - - L 2126 /- /- /1385 /895 /- HORZ(TL): 0.118 B - - Wind reactions based on MWFRS Creep Factor: 2.0 R Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.814 L Brg Width = 8.0 Min Req = 2.5 Max BC CSI: 0.742 Bearings R & L are a rigid surface. Max Web CSI: 0.731 Bearings R & L require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:221.2lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.01.01A.0724.12 A- B 245 -707 F - G 1493 -1548 B - C 1958 - 2659 G - H 1480 -1681 C - D 2006 -2575 H -1 866 -1108 D - E 2017 - 2545 I - J 843 -1112 E - F 1742 -2047 J - K 872 _-1227 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. R - Q 2428 -1654 O - N 1887 -1235 A-R 711 -219 N-M 1021 -651 Q - P 2337 -1640 M - L 1021 - 651 P - O 2337 -1640 L - K 1218 - 758 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp R - B 1877 -2165 F - N 536 -508 C - Q 207 - 29 N - G 244 - 83 Q - E 232 -40 N - H 798 - 699 E - O 553 - 566 H - L 1955 - 2097 F - O 570 -263 L - J 580 -454 -WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines theresponsibilitiesand duties of the Truss Fart Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvriaht Q 201E A-1 Rnnf Tnr. sac - R-Murtinn of this dnnrmxnt: In anv In- is nrnhihited vrithnut tha v ritten nennicainn of A-1 Rnnf Tnr. sas. Job CHHS3B Truss A07 Truss Type Qty Ply HIPS 1 1 02/09/2021 2616 11 12 4 p B 1=3X6(Cy =3X6(C6) F TLA SAPT TE REQ. 16'6" 1 V4" i166" 1 =5X6 III1.5X4 =5X6 E F G X6 3X4CD H \ 1 4, 3X6 Q P O N M L 1113X6 K III1.5X3 =3X4 =H0308 =3X8 =H0308 =4X4 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 25.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h C&C Dist a: 4.43 ft Loc. from endwall: not in 13.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.0E + SP M-31; T3,T4 2x4 SP #2; Bot chord: 2x4 :SP 2400f-2.OE + SP M-31 B2 2x4 SP M-30; B3 2x4 SP #2; Webs: 2x4 SP #3; W6 2x6 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 16.50 27.83 BC 56 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. J 21X6(A1) SEAT PLATE REQ. 364" T6" -{ i 44'4" 1 j Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code:FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl U# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.205 P 999 360 Loc R+ / R- / Rh / Rw / U / RL R 1520 /- /- 1896 /685 /147 Rep Factors Used: Yes VERT(CL): 0.430 P 969 240 FT/RT:10(0)/10(10) HORZ(LL): -0.068 B - - K 2112 /- /- /1387 /900 /- Plate Type(s): HORZ(TL): 0.144 B - - Wind reactions based on MWFRS WAVE, HS Creep Factor: 2.0 R Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.804 K Brg Width = 8.0 Min Req = 2.5 Max BC CSI: 0.997 Bearings R & K are a rigid surface. Bearings R & K require a seat plate. Max Web CSI: 0.970 Maximum Top Chord Forces Per Ply (Ibs) I Wgt:214.2lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.01.01A.0724.12 A - B 496 -922 F - G 1936 -2044 B - C 2131 - 2683 G - H 970 -1094 C - D 2055 - 2545 H -1 945 -1112 D - E 2081 - 2535 I - J 915 -1139 E - F 1936 - 2044 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp R - Q 2470 -1832 N - M 1506 -1123 A - R 913 -464 M - L 1506 -1123 Q - P 2475 -1839 L - K 1040 - 707 P - O 2088 -1544 K - J 1135 - 789 O - N 2088 -1544 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. R - B 1831 -1961 F - N 497 - 281 Q - C 198 -144 N - G 820 - 724 C - P 303 -188 G - L 1137 - 976 P - E 480 -184 L - I 1594 -1302 E - N 237 -164 1 - K 1844 -1960 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineeririg (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pieroe, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon inventing by all parties involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. r-rinht (e 2016 A4 Roof Tn,ss-- Renrodud. ion of this dorj,ment. in am form. is nrahihited without the written nermi-1- of A-1 Roof Tmcses. Job Truss Truss Type CHHS3B A08 HIPS I Qty I Ply 02/09/2021 1 1 2613 14'6" 1164" -{- 14'6" -I =5X8 III1.5X4 12 D E F T 417 o3X4C (a) �4X6 in A�3X4 B (a) H �3X4 I P O N M L K J 1113X6 1111.5X3 =3X4=3X6 =3X10 =3X6=4X6 SEAT PLATE REQ. SEAT PIJt4TISREQPLAT66EQ ak, %IRRIEQ. I-116 35' 5'4" ­j L'1 44'4" Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defi/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): 0.212 O 999 360 Loc R+ / R- / Rh / Rw '/ U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.424 O 982 240 Q 1526 /- /- /883 /708 /130 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.058 B - - J 1842 /- /- /950 /771 P EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.117 B - - J* 24 P P ' /14 /3 P Des Ld: 40.00 Mean Height: 25.00 ft WAVE Creep Factor: 2.0 R 337 /-119 P 1160 /168 P NCBCLL: 10.00 TCDL: 5.0 sf p Max TC CSI: 0963 Wind reactions based on MWFRS Load Duration: 1.25 BCDL: 5.0 psf " . Max BC CSI: 0.964 Q Brg Width = 8.0 Min Req = 1.5 Spacing: 24.0 MWFRS Parallel Dist: h/2 to h J Brg Width = 8.0 Min Req = 2.2 C&C Dist a: 4.43 ft Max Web CSI: 0.758 J Brg Width = 64.0 Min Req = - Loc. from endwall: not in 13.00 ft Wgt: 224.7 Ibs R Br Width = 8.0 9 Min Re 1.5 q = GCpi: 0.18 Bearings Q, J, J, & R are a rigid surface. Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 Bearings Q, J, J, & R require a seat plate. Lumber Maximum Top Chord Forces Per Ply (Ibs) Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.OE + Chords Tens.Comp. Chords Tens. Comp. SP M-31; Bot chord: 2x4 SP #2; B1 2x4 SP 2400f-2.OE + A - B 524 -838 E - F 2420 -2372 SP M-31; B - C 2335 -2690 F - G 1568 -1580 Webs: 2x4 SP #3; W6 2x6 SP #2; C - D 2325 -2493 , G - H 604 -267 Lt Slider: 2x6 SP #2; block length = 2.750' D - E 2420 -2372 H - 1 657 -724 Rt Slider: 2x6 SP #2; block length = 2.750' Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) Continuous lateral restraint equally spaced on member. Q - P 2467 -2052 M - L 1435 -1189 A - Q 835 - 504 L - K 1435 -1189 Plating Notes P - O 2468 -2059 K - J 230 -420 All plates are 3X6(C6) except as noted. O - N 2320 -1939 J - R 619 -1069 N - M 2320 -1939 Purlins In lieu of structural panels or rigid ceiling use purlins Maximum Web Forces Per Ply (Ibs) to laterally brace chords as follows: Webs Tens.Comp. Webs Tens. Comp. Chord Spacing(in oc) Start(ft) End(ft) TIC 24 14.50 29.83 Q - B 1974 - 2075 M - F 1140 -1059 BC 71 0.00 44.33 P - C 213 -29 F - K 614 - 586 Apply purlins to any chords above or below fillers C - O 211 -250 K - G 1899 -1395 at 24" OC unless shown otherwise above. D - O 365 -8 G - J 1526 -1728 D - M 145 -348 H - R 623 -593 Wind E - M 740 -482 Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field the Truss, including handling, installation bracing be the responsibility the Building Designer and Contractor. All notes set out in the TDD and the and 4451 St. Lucie Blvd, Suite 201 use of storage, and shall of practices guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon inventing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined. in TPI-1. C nvdnht A 2016 A-1 Rnnf Tmrsr_c - RenrndurAinn of this d-ment. in anv in'm, is nmhihned without the written nerni-1- of A-1 Rnnf hisses. Job CHHS36 Truss A09 r 11'11-11/16" 12 T4 p E=== m 3X4 D 175 ip 4X636BC6)C 3X4 1 6-T16 U T 1111.5X3 =3X4 Truss Type City Ply 02/09/2021 HIPS 11 11 19'4" -{- =3X4 =3X6 III1.5X3 J R =H0308 =3X4 W r =3X8 =HO308 v =3X4 2621 J--3X4 4X6(C6) K-3X6(C6) L�3X4 N 1111.5X3 11 t11 116QTE REQ. 41'4" SEAT 11 1T1 /,&Q. T/ f6 43'3-3/8" 6-1v5/16„ Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 _ Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.339 H 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.684 H 714 244 B 1788 /- /- /1002 /822 /118 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.092 N - - L 1788 /- /- /1002 /822 /- J EXP: C Kzt: NA Des Ld: 40.00 Plate Type(s): HORZ(TL): 0.187 N - - 'Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE, HS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 2.1 : 10.00 BCDL: 5.0 psf NCBLoad Max TC CSI: 0.769 L Brg Width = 8.0 Min Req = 2.1 Du Load Duration: 1.25 BCDL: 5.0 psf " Max BC CSI: 0.989 Bearings B & L are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h/2 to h Bearings B & L require a seat plate. C&C Dist a: 4.43 ft Max Web CSI: 0.999 Loc. from endwall: not in 6.50 ft Maximum Top Chord Forces Per Ply (Ibs) 'Tens.Comp. Wgt: 232.4 Ibs Chords Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 A- C 667 -971 G - H 3786 -3944 Lumber C - D 2959 -3370 H -1 3788 -3946 Top chord: 2x6 SP 2400f-2.OE; T2,T3 2x4 SP #2; D - E 3135 -3402 I - J 3133 -3401 Bot chord: 2x4 SP M-30; B2 2x4 SP #2; E.- F 3766 -3927 J - K 2960 -3371 Webs: 2x4 SP #3; F - G 3786 - 3944 K - M 669 - 972 Lt Slider: 2x4 SP #2; block length = 1.750' Rt Slider. 2x4 SP #2; block length = 1.750' Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Bracing (a) Continuous lateral restraint equally spaced on A - B 1003 -675 R - Q 3950 -3465 member. B - U 3068 -2608 Q - P 3194 -2738 U - T 3067 -2613 P - 0 3194 -2738 Purlins T - S 3195 -2742 O - N ' 3068 -2612 In lieu of structural panels or rigid ceiling use purlins S - R 3195 -2742 N - L 3069 -2608 to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) Maximum Web Forces Per Ply (Ibs) TC 24 11.97 31.31 Webs Tens.Comp. Webs Tens. Comp. BC 54 0.00 43.28 Apply purlins to any chords above or below fillers B - C 2487 -2647 H - Q 548 -353 at 24" OC unless shown otherwise above. U - D 178 -2 Q - 1 896 -964 D - T 207 -389 1-0 236 -1 Wind E-T 236 0 O-J 210 -386 Wind loads based on MWFRS with additional C&C E - R 878 -938 J - N 178 -3 member design. R - F 584 -360 K - L 2487 -2646 Wind loading based on both gable and hip roof types. - F - Q 77 -71 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineen . nE Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the 91231 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss _ Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C'.-d.ht a12n1a A-1 RoofT.,. -s- Renmdurtion of this d—anent. in am form. is nmhihited withnut tha written nannissinn of A-1 Rnnf Tnrr sec. Job CHHS3B to - �l 4) ih 6-1116' Truss Truss Type Qty Ply A10 HIPS 11 11 i-9'11-11/16" A.234" 12 =6X8 =3X4 =H0306 III1.5X4 4 p D E F G 02/09/2021 2635 9'11-11 /16" -{ =6X8 H 4X4 (a) (a) (a) = 4X6(C 1-3J 6(C64 6(C6)BC6)C K A 0 P O N M L III1.5X3 =H0308=4X4=4X8=H0308 III1.5X3 3) 1 1 j11 /16QTE REQ. 41'4" SEAT 1111T1 /116�`0 6-f)6" 43'3-3/8" r Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code:FBC 7th Ed. 2020 Res. PP Deflection in Ioc�Udefl U# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.429 G 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.863 G 566 244 B 1788 P /- /1003 /934 /101 BCDL: 10.00 Risk Category: 11 FT/RT:10(0)/10(10) HORZ (LL): 0.099 I - - J 1788 /- /-, /1003 /934 /- EXP: C Kzt: NA Plate Type(s):, HORZ(TL): 0.201 1 - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 25.00 ft WAVE, HS Creep Factor: 2 B Br Width = 8.0 Min Re 1.5 NCBCLL: 10.00 TCDL: 5.0 psf 0. Max TC CSI: 0.779 J Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf Max BC CSI: 0.949 Bearings B & J are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Bearings B & J require a seat plate. C&C Dist a: 4.43 ft Max Web CSI: 0.769 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 6.50 Wgt: 215.6 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 A- C 967 -1287 F - G 4550 -4676 Lumber C - D 3308 -3574 G - H 4552 -4677 D - E 4518 -4648 H -1 3305 -3573 Top chord: 2x6 SP 2400f-2.0E; T2,T3 2x4 SP M-30; E - F 4550 -4676 I - K 962 -1282 Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:; B2 2x4 SP M-30; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x4 SP #2; block length = 1.750' Chords Tens.Comp. Chords Tens. Comp. Rt Slider: 2x4 SP #2; block length = 1.750' A - B 1315 -995 O - N 4685 -4286 Bracing B - Q 3284 -2927 N - M 3286 -2916 (a) Continuous lateral restraint equally spaced on Q - P 3288 -2921 M - L 3286 -2916 member. P - O 3288 -2921 L - J 3282 -2922 Purlins Maximum Web Forces Per Ply (Ibs) In lieu of structural panels or rigid ceiling use purlins Webs Tens.Comp. Webs Tens. Comp. to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) B - C 2690 -2529 N - H 1533 -1620 TC 24 9.97 33.31 D - Q 290 0 G - N 691 -457 BC 57 0.00 43.28 D - O 1504 -1581 L - H 294 0 Apply purlins to any chords above or below fillers d - E 719 -463 1- J 2693 -2533 at 24" OC unless shown otherwise above. E - N 82 -58 Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. r -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on.the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and anyfield # 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvriaht 0 2016 A-1 Rmf Tmscen - Renmdurlinn of thin dnmment. in anv form. is nmhihited withnut the wriftnn nermiccinn of A-1 Rmf Tms"es. Job CHHS3B . Truss Truss Type A11 HIPS 1ty 1y I oz/as/zozl 1 2629 -7'11-11/16" -1- r� 4 p =6X10 D =3X6(C6)C 4X4 1s/1s° =4X6A(C6)B 1 sTis =3X4 ' E (a) 27'4" 1111.5X4=4X6 F G =3X4 =6X10 H I (a) =4X6(C6) J=-3X6(C ) 4Xdd K� L S R Q P O N M IIII.5X3 =4X6=H0308 =3X8 =H0308=4X6 1111.5X3 gE T L 1111-1 /16QTE REQ. 41'4" Lq �R SEAT 11 1T7 /ffiC. Ai"1 r 43'3-3/8" 6-$/16" Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl U# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.606 F 806 360 Loc R+ / R- ! Rh' / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 1.222 F 400 244 B 1788 /_ /_ /1001 /935 /83 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.098 M - - K 1788 /- /- /1001 /935 /- EXP: C Kzt: NA Des Ld: 40.00 Plate Type(s): HORZ(TL): 0.199 M - - Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE, HS Creep Factor: 2.0 B Big Width = 8.0 Min Req = 1.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.719 K Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf " Max BC CSI: 0.956 Bearings B &-K are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 Bearings B & K require a seat plate. C&C Dist a: 4.43 ft Max Web CSI: 0.817 Loc. from endwall: not in 6.50 f Maximum Top Chord Forces Per Ply (Ibs) Wgt: 211.4 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 20.01.01A.0724.12 A- C 1066 -1275 G - H , 5775 -5905 Lumber C - D 3398 -3575 H -1 5159 -5255 Top chord: 2x6 SP 2400f-2.OE; T2,T3 2x4 SP M-30; D - E 5159 -5255 I - J 3398 -3575 Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:; E - F 5775 -5905 J - L 1066 -1275 B2 2x4 SP M-30; F - G 5775 -5905 Webs: 2x4 SP #3; Lt Slider: 2x4 SP #2; block length = 1.750' Maximum Bot Chord Forces Per Ply (Ibs) Rt Slider: 2x4 SP #2; block length = 1.750' Chords Tens.Comp. Chords Tens. Comp. Bracing A - B 1308 -1090 P - O 5322 -5006 (a) Continuous lateral restraint equally spaced on B - S 3283 -3020 O - N 5322 -5006 member. , S - R 3286 -3013 N - M 3286 -3011 R - Q 5322 - 5008 M - K 3283 - 3019 Purlins Q - P 5322 -5008 In lieu of structural panels or rigid ceiling use puffins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. Webs Tens. Comp. TC 24 7.97 35.31 BC 53 0.00 43.28 B - C 2640 - 2543 P - H 643 - 652 Apply purlins to any chords above or below fillers D - S 213 0 H - N 894 - 679 at 24" OC unless shown otherwise above. D - R 2144 -2177 N -1 2144 -2177 Wind R - E 894 - 679 M -1 _ 213 0 E - P 643 -652 J - K 2640 -2543 Wind loads based on MWFRS with additional C&C F - P 561 -377 member design. Wind loading based on both gable and hip roof types. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Tmss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced forgeneral guidance. TPI.1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. Cnnvriaht 0 2n16 A-1 Rnnf Tri-- Ranrndurtinn of this dmime.nt. in anv form. is nmhihited withnut tha written nanniz inn of A-1 Rnnf Tn _ c %. Job Truss Truss Type Qty I Ply CHHS313 I Al2 I HIPS 11 2 02/09/2021 2632 t i 6'6" 207# # 122# 122# 122# 122# # 122# 122# 122# # 122# 122# 122# 122# 207# 122122# i i i i i i i 1221 i i i 1221 i i i i �__ 6'6-3/8" -� 31'4" 6'6" �{ 12 4 =6X10 =4X4 1111.5X3=H0510 =3X4 =H0308=4X4 =6X10 C D E F G H I J T B (C6) �3X4 -3K (34=4X6(C6) rstsits =4X6 C6 ( )IL A L 1 a+3� T S R Q P O N M V 1111.5X3 =3X10 =H0510 =3X10 =4X4 =H0510 =3X10 III1.5X3 SEAT PLATE REQ. 41'4" SEAT PLACE REQ.tf-1'B 6 "I 1 44 4" -� 6'6-3/8" - 3/8' 2' } 2' + 2' 2' 2' 2' -] 7-1 /A 7 114� 2 2 t 2 -}- 2 2 -{� 2' _P 3/8' 191# 82# 82# 82# 82# 82# 82# 82## 82'#= 82# 82# 82#v 82# 82# 82# 82#• 82#i 1911## Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. v PP Deflection in loc Udefi L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): -0.967 E 505 360 Loc R+ / R- / Rh / Rw / U / RL U 3092 /- /- /- /2083 BCLL: 0.00 Enclosure: Closed Rep Factors Used: No VERT(CL): 1.586 E 308 244 BCDL: 10.00 Risk Category: 11 9 ry: FT/RT:10 0 /10 10 HORZ(LL): -0.119 C - - V 3092 /- /- /- /2083 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.196 C - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 25.00 fit WAVE, HS Creep Factor: 20. U Br Width = 8.0 Min Re 1.5 9 q = NCBCLL: 0.00 TCDL: 5.0 sf p Max TC CSI: 0.929 V Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf Max BC CSI: 0.989 Bearings U & V are a rigid surface. Spacing: 24.0 " MWFRS'Parallel Dist: 0 to h/2 Bearings U & V require a seat plate. C&C Dist a: 4.43 ft Max Web CSI: 0.707 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 6.50 L Wgt:467.6lbs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 VIEW Ver: 20.01.01A.0724.12 A - B 1308 -1942 G - H 4832 -7083 Wind Duration: 1.60 B C 21AR -3047 H -1 4832 -7083 Lumber Top chord: 2x4 SP M-30; T2,T3 2x4 SP 2400f-2.OE + SP M-31; Bot chord: 2x6 SP 2400f-2.OE; Webs: 2x4 SP #3; W2 2x4 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Rt Slider: 2x4 SP #3; block length = 1.750' Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @12.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1)1/2" bolts may be used for (2) 0.131"x3", min. nails on The Bottom Chord Only. Special Loads --(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 61 plf at 0.00 to 61 plf at 6.50 TC: From 31 plf at 6.50 to 31 plf at 37.83 TC: From 61 plf at 37.83 to 61 plf at 44.33 BC: From 20 plf at 0.00 to 20 plf at 6.53 BC: From 10 plf at 6.53 to 10 plf at 37.80 BC: From 20 plf at 37.80 to 20 plf at 44.33 TC: 207 lb Conc. Load at 6.53,37.80 TC: 122 lb Conc. Load at 8.56,10.56,12.56,14.56 16.56,18.56,20.56,22.17,23.77,25.77,27.77,29.77 31.77,33.77,35.77 BC: 191 lb Conc. Load at 6.53,37.80 ' BC: 82 lb Conc. Load at 8.56,10.56,12.56,14.56 16.56,18.56,20.56,22.17,23.77,25.77,27.77,29.77 31.77,33.77,35.77 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 6.50 37.83 BC 76 0.00 44.33 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. C - D 3943 - 5767 I - J 3933 - 5750 D - E 4832 - 7076 J - K 2110 - 3054 E - F 4832 - 7076 K - L 1319 -1956 F - G 4832 - 7076 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. U - T 2847 -1966 P - O 5855 -4020 A - U 1881 -1260 O - N 51155 -4020 T - S 2834 -1949 N - M 2841 -1954 S - R 5870 - 4029 M - K 2854 -1971 R - Q 5870 -4029 K - L 1895 -1271 Q - P 7121 -4873 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - T 265 -210 G - P 305 -276 C - S 3107 -2107 P -1 1308 -862 S - D 634 - 760 I - N 642 - 774 D - Q 1281 -850 N - J 3081 -2090 E - Q 302 - 272 M - J 262 - 204 Q - G 44 -50 -WARNING" , Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes an this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineefinE Ryan Bays, PZ responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability anduse of this Truss for any Building is the # 91231 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are,referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. Convrinht 0 2o1R A-1 Rmf Tnicsas - Ranrndmntim of this dnoument. in anv fnm. is nrnhihited without the written narmission of A-1 Rmf Tnissec. Job CHHS3B y Truss Truss Type B01 I SPEC Qty Ply 3 I1 02/09/2021 2651 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " I r 67-11V 1 2'4-1/8• 1 6'2-7/8' �{ 1s'z-ve• ®sx4 -4z4 T,44 iATE REO. RR14'8• 1117/8+ 67-1/8•t2'4-1/8' 1 62-7/8' -� Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x8 SP 2400f--1.8E; T2 2x4 SP 2400f-2.0E + SP M-31; Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:; B2 2x6 SP 2400f-2.OE; Webs: 2x4 SP #3; W4 2x8 SP 2400f-1.8E; W7 2x6 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 72 0.00 5.99 BC 67 9.53 15.10 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. t it j 1014-3/4' t57-1/8' 4' .g" 1504 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): 0.276 F 614 360 Loc R+ / R- / Rh / Rw / U / RL Rep Factors Used: Varies by Ld C %1t-:RT(CL): 0.706 F 240 240 B 787 /_ /_ /403 /272 /278 FT/RT:10(0)/10(10) HORZ(LL): 0.120 M - - K 852 /- /- /294 /297 /- Plate Type(s): HORZ(TL): 0.307 M - - Wind reactions based on MWFRS WAVE, HS Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.669 K Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.199 Bearings B & K are a rigid surface. Max Web CSI: 0.349 Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 117.6lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 20.01.01A.0724.12 B - C 135 -509 E - F 159 -586 F-G 4814 -5061 G-H 710 -1165 A-B 15 0 H-1 716 -1147 C - D 487 -1026 I - J 64 - 98 D - E 526 -1021 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - O 920 - 827 G - M 1389 -1063 O - N 825 -700 M - L 1391 -1073 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B-C 984-1104 M-1 319 -190 D -i0 233 -136 I - L 1173 -1503 O - E 129 -158 L - K 666 - 851 E - N 1158 -1356 L - J 155 - 72 N-F 1211 -1004 -WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvriaht 0 2016 A-1 Roof Tniccr-c - Ranrod-lion of this domiment. in anv form. iv nrohihited without tha wdttan nnrmiceion of A-1 Ronf Tni-s. Job Truss Truss Type Qty Ply 02/09/2021 2592 CHHS3B I B02 HIPM 11 I 1 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " a-1T6• 14'6" 1- 1'8" --� SEAT PLATE REQ. 1'6" j 14'8" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 2.750' Bracing (a) Continuous lateral restraint equally spaced on member. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 14.50 16.17 BC 75 0.00 16.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE 16'2" Defl/CSI Criteria PP Deflection in loc L/defl U# VERT(LL): 0.058 C 999 36, VERT(CL): 0.118 C 999 24, HORZ(LL): -0.027 B - - HORZ(TL): 0.055 B Creep Factor: 2.0 Max TC CSI: 0.807 Max BC CSI: 0.667 Max Web CSI: 0.937 Wgt: 88.9 Ibs VIEW Ver: 20.01.01A.0724.12 es5X6 1111.5X3 D E SEAT PLATE REQ. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL H 737 /- P /454 /262 /253 1 578 /- P 1313 /272 /- Wind reactions based on MWFRS H Brg Width = 8.0 Min Req = 1.5 1 Brg Width = 8.0 Min Req = 1.5 Bearings H & I are a rigid surface. Bearings H & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 85 -489 C - D 783 -962 B- C 622 - 955 D- E 0 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. H - G 868 - 882 G - F 155 - 211 A-H 519 -53 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. H - B 1059 -1025 D - F 652 - 480 C-G 566 -361 E-F 117 -50 G - D 848 - 776 13. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin P.E. , n Bays responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rya # Bays, responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are,referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvrioht Q 2n16 A-1 Rmnf T.n s — Ranrodmction of this dnoumant. in am fn=. is nmhihftad without tha writtan narmissinn of A-1 Rnnf Tni. sas. Job Truss Truss Type CHHS3B I B03 HIPM Qty I Ply 1 1 02/09/2021 2593 3-iT- SEAT PLATE REQ. 1,6„ - j 12'6" 16'2" 14'8" 3'8" -{ =5X6 III1.5X4 D E SEAT PLATE REO. to -v Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.054 C 999 360 Loc R+ / R- / Rh / Rw / U / RL BOLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.108 C 999 240 H 737 /- /- /454 /274 /218 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.024 B - - 1 578 /- /- /307 /288 /- EXP: C Kzt: NA Des Ld: 40.00 Plate Type(s): HORZ(TL): 0.050 B - - Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE Creep Factor: 2.0 H Br Width = 8.0 Min Re 1.5 9 q = NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.659 1 Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf " Max BC CSI: 0.826 Bearings H & I are a rigid surface. 24.0 MWFRS Parallel Dist: h/2 to h Bearings H & I require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.537 Loc. from endwall: not in 9.00 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 81.9 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 A - B 115 -412 C - D 883 -985 Lumber B- C 759 -988 D- E 0 0 Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Maximum Bot Chord Forces Per Ply (Ibs) Webs: 2x4 SP #3; Chords Tens.Comp. Chords Tens. Comp. Lt Slider: 2x6 SP #2; block length = 2.750' H - G 898 -964 G - F 336 -490 Purlins A-H 443 -79 In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Maximum Web Forces Per Ply (Ibs) Chord Spacing(in oc) Start(ft) End(ft) Webs Tens.Comp. Webs Tens. Comp. TC 24 12.50 16.17 BC 75 0.00 16.17 H - B 1076 -1076 D - F 745 -510 Apply purlins to any chords above or below fillers C - G 451 -252 E - F 257 -112 at 24" OC unless shown otherwise above. G - D 672 1541 Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. Thedesign assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pieroe, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C—rinht 0 2n16 A-1 Rnof Tnrscr_c - RnnrM ation of thi.q doormen. in env form. is nrohibited withnut the written nermi-inn of A-1 Ronf Tni—, Job Truss Truss Type Qty Ply 02/09/2021 CHHS3B I B04 I HIPM 11 11 2594 3-1T6- 10'6" -1 5'8" =j SEAT PLATE REQ. 1'6" 14'8" 167' =5X6 1113X4(R) D E Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-16 Code:FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# TCDL: 10.00 Speed: 160 mph' TPI Std: 2014 VERT(LL): -0.040 C 999 36, BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.064 C 999 24, BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.008 F - - EXP: C Kzt: NA r Plate Type(s): HORZ(TL): 0.014 B - - Des Ld: 40.00 Mean Height: 25.00 ft WAVE' Creep Factor: 2 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.759 Load Duration: 1.25 BCDL: 5.0,psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.710 C&C Dist a: 3.00 ft Max Web CSI: 0.729 Loc. from endwall: not in 9.00 Wgt: 86.1 Ibs GCpi: 0.18 VIEW Ver: 20.01.01A.0724.12 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 10.50 16.17 BC 75 0.00 16.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. N o� ih 1 SEAT PLATE REQ. ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL H 737 /- P /452 1434 1258 1 578 ; /- P /302 /414 P Wind reactions based on MWFRS H Brg Width = 8.0 Min Req = 1.5 1 Brg Width = 8.0 Min Req = 1.5 Bearings H & I are a rigid surface. Bearings H & I require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 85 - 519 C - D 773 - 695 B-C 951 -886 D-E 819 -617 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. H - G 804 -1074 G - F 10 - 20 A - H 538 - 59 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. H - B 1352 - 983 G - E 721 - 949 C - G 294 -192 E - F 859 - 537 D - G 525 -177 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine i connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the. Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the Too and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cnnvriaht t%2n16 A-1 Rnof Tniecr_a — RnnrnduMinn of thic dnnrment. in anv fnnn. i. nmhihited wlthnul the vmttnn nenniscinn of A-1 Rnnf T., c . Job CHHS3B Loading Criteria (psf) TOLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Truss Truss Type Qty Ply 02/09/2021 B05 HIPM 11 11 354+ 181# 181+ 181 1'7-1/4" I 3IKIe' 8'6° -{- 7'8° m2x4 SEPLATE REQ. SEAT PLATE REQ. �^ 1'6' AT 14W - - i Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 :SP 2400f-2.OE + SP M-31:; T2 2x4 SP #2; Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:; B2 2x4 SP M-30; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 2.750' Special Loads --(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 61 plf at 0.00 to 61 plf at 8.50 TC: From 31 pif at 8.50 to 31 plf at 16.17 BC: From 20 plf at 0.00 to 20 plf at 8.65 BC: From 10 plf at 8.65 to 10 plf at 16.17 TC: 354 lb Conc. Load at 8.53 TC: 181 lb Conc. Load at 10.56,12.56,14.56 BC: 422 lb Conc. Load at 8.53 BC: 122 lb Conc. Load at 10.56,12.56,14.56 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 8.50 16.17 BC 69 0.00 16.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. 16'2° 2'0-3/8" # 2 --�- 2 122 422# 122 122# 2609 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.117 C 999 360 Loc R+ / R- / Rh / Rw / U / RL I 1294 /- /- /- /925 /- Rep Factors Used: Varies by Ld C %q_RT(CL): 0.200 H 107 240 FT/RT:10(0)/10(10) HORZ(LL): 0.064 B - - J 1394 P P P /1005 P Plate Type(s): HORZ(TL): 0.132 B - - Wind reactions based on MWFRS WAVE Creep Factor: 2.0 1 Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.704 J Brg Width = 8.0 Min Req = 1.6 Max BC CSI: 0.976 Bearings I & J are a rigid surface. Max Web CSI: 0.755 Bearings I & J require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt:83.3lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 20.01.01A.0724.12 A-B 192 -586 C-D 1161 -1597 B - C 1590 -2143 D - E 1161 -1597 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. I - H 1958 -1440 H - G 1981 -1445 A-1 582 -182 G-F 10 -7 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. I - B 1525 -1768 D - G 626 - 574 C - H 450 - 99 G - E 1982 -1441 C-G 354 -480 E-F 1011 -1318 *'WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin an Bays P.E. RyanBays, responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the , 91231 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilifies and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Cn-riaht 0) 2016 A-1 Rnnf Tmssas - Rann dLidinn of this dmimnnt. In am fnnn, is nmhib0ed wirhnuf the written nenniscinn of A-1 Rnnf Tnrsses. Job Truss Truss Type Qty Ply 02/09/2021 CHHS3B B06 I HIPM 11 I1 2595 3-1T' i - 2'6" SEAT PLATE REQ. �_ 1'6" i 14'4" 1710" -6X6 1H3X6(R) F G iK 0 SEAT PLATE REQ. 20'8^ 22'2" Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VER7(LL): -0.102 1 209 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.170 D 999 240 J 1153 /- /- /745 /563 /298 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.048 C - - K 815 P /- /423 /444 !- EXP: C Kzt: NA Des Ld: 40.00 Plate Type(s): HORZ(TL): 0.067 C - Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE Creep Factor: 2.0 J Brg Width = 8.0 Min Req = 1.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.720 K Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf Bearings J & K are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h Max BC CSI: 0.552 Bearings J & K require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.769 Loc. from endwall: not in 9.00 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 128.8lbs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 B - C 85 -657 D - E 871 -1005 Lumber A- B 52 0 E- F 889 -980 C - D 1205 -1445 F - G 948 -895 Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE + SP M-31; Bot chord: 2x6 SP 2400f-2.OE; B2 2x6 SP #2; Maximum Bot Chord Forces Per Ply (Ibs) Webs: 2x4 SP #3; Chords Tens.Comp. Chords Tens. Comp. Lt Slider: 2x4 SP #3; block length = 1.750' J-B 761 -99 I -H 0 0 Bracing J -1 1324 -1371 (a) Continuous lateral restraint equally spaced on Maximum Web Forces Per Ply (Ibs) _member. Webs Tens.Comp. Webs Tens. Comp. Purlins' In lieu of structural panels or rigid ceiling use purlins B - C 1557 -1171 I - G 1051 -1112 to laterally brace chords as follows: D - 1 428 -446 G - H , 981 -747 Chord Spacing(in cc) Start(ft) End(ft) F - I 649 -249 TC 24 14.33 22.17 BC 120 0.00 22.17 Apply purlins to any chords above or below fillers at 24" CC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and. use of this Truss for any Building is the i # 91231 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SECA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. C.nnvrinht ® 2W A-1 Rmf Tnisses — Renrndurtim of this dn—Ant. In anv fern. is nrnhihifed vrithnut the written nerminslan of A-1 RmfTnisses. Job Truss Truss Type Qty Ply 02/09/2021 2596 CHHS3B I B07 I HIPM 11 I 1 12'6" SEAT PLATE REQ. 1'6" 'A - 9,8„ =5X6 =3X4 1111.5X4 D E F 20'8" 22'2" L SEAT PLATE REQ. I L6 1 A Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in Ibc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.084 C 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.168 C 999 240 K 978 /- /- 1581 /374 /218 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): -0.030 B - - L 823 /- /- /430 /479 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.060 B - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 25.00 ft WAVE Creep Factor: 2.0 K Brg Width = 8.0 Min Req = 1.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.810 L Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 sf p " Max BC CSI: 0.966 Bearings K & L are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h/2 to h Bearings K & L require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.734 Maximum Top'Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 Wgt: 114.1 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.12 A- B 180 -282 D - E 1185 -1064 Lumber B- C 1290 -1430 E- F 0 0 C - D 1162 -1168 Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; B2 2x4 SP M-30; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x6 SP #2; block length = 2.750' Chords Tens.Comp. Chords Tens. Comp. Purlins K - J 1303 -1412 1- H 1303 -1417 In lieu of structural panels or rigid ceiling use purlins A - K 279 -159 H - G 720 -976 to laterally brace chords as follows: J -1 1303 -1417 Chord Spacing(in oc) Start(ft) End(ft) TC 24 12.50 22.17 Maximum Web Forces Per Ply (Ibs) BC 87 0.00 22.17 Webs Tens.Comp. Webs Tens. Comp. Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. K - B 1408 -1342 H - E 473 -279 J - C 131 -4 E - G 1294 - 954 Wind C - H 242 -257 F - G 236 -120 Wind loads based on MWFRS with additional C&C D - H 213 -5 member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn P.E. , Bays Ryan Ry responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Bays, responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any Feld use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucia Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specially Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in waiting by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building, All capitalized terms are as defined In TPI-1. Cnnvrinht (lc 2m1e A-1 R,mf T.,—, — Renrodmrlinn of this dom,ment. in anv fm— is nrohihited i0hmd the v ritt- ri—msion of A-1 Rnof Tn,--. Job Truss Truss Type Qty Ply 02/09/2021 CHHS3B I B08 HIPM 1 1 25s7 3.15�1a' SEAT PLATE REQ. 1'6" �— 10'6" i11,8" 20'8" 1111.5X4 iL SEAT PLATE REQ. II Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): -0.079 C 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.138 J 999 240 K 978 P /- /578 /603 /258 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ (LL): -0.018 G - - L 823 /- /- /426 l569 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.030 G - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 25.00 ft WAVE Creep Factor: 20. K Br Width = 8.0 Min Re 1.5 9 q = NCBCLL: 10.00 TCDL: 5.0 sf p Max TC CSI: 0.849 L Brg Width = 8.0 Min Req = 1.5 Load Duration: 1.25 BCDL: 5.0 psf Max BC CSI: 0.955 Bearings K & L are a rigid surface. Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Bearings K & L require a seat plate. C&C Dist a: 3.00 ft Max Web CSI: 0.705 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 f Wgt: 118.3 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver: 20.01.01A.0724.121A - B 66 -340 D - E 1357 -1040 Lumber B - C 1477 -1395 E - F 1357 -1040 C-D 1442 -1313 Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Lt Slider: 2x6 SP #2; block length = 2.750' Chords Tens.Comp. Chords Tens. Comp. Bracing K - J 1262 -1520 I - H 1214 -1457 A - K 343 -64 H - G 11 -15 (a) Continuous lateral restraint equally spaced on J -1 1214 -1457 member. Purlins Maximum Web Forces Per Ply (Ibs) In lieu of structural panels or rigid ceiling use purlins Webs Tens.Comp. Webs Tens. Comp. to laterally brace chords as follows: K - B 1733 -1405 E - H 821 - 395 Chord Spacing(in cc) Start(ft) End(ft) C - J 209 -206 H - F 1203 -1569 TC 24 10.50 22.17 BC 67 0.00 22.17 D - J 265 0 F - G 1106 - 772 Apply purlins to any chords above or below fillers D - H 148 -204 at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to Wind pressure. Wind loading based on both gable and hip roof types. "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval 'of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. - C nvdoht 0 201E A-1 Rnnf Tmacr_c — Renmduotion of this do —Ant. in anv fnnn. is nrnhihited without the written nennission of A-1 Roof Tmcses. Job CHHS3B Truss Truss Type B09 HIPM Qty Ply 102/09/2021 1 1 2648 Loading Criteria (psfi TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " i 8W 174181 #+ 181 + 18144 181 4 1811 1814 181V_ 3/4" ITS" E-o5X8 1114X4 K 0 SEAT PLATE REQ. SEAT PLATE REQ. 1.6' 20'8" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 :SP 2400f-2.OE + SP M-31:; Bot chord: 2x6 SP 2400f-2.OE; Webs: 2x4 SP #3; W3 2x4 SP #2; Lt Slider: 2x4 SP #3; block length = 1.750' Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25) TC: From 61 plf at 0.00 to 61 plf at 8.50 TC: From 31 plf at 8.50 to 31 plf at 22.17 BC: From 20 pif at 0.00 to 20 plf at 8.50 BC: From 10 plf at 8.50 to 10 pif at 22.17 TC: 174 lb Conc. Load at 8.50 TC: 181 lb Conc. Load at 9.15,11.15,13.15,15.15 17.15,19.15,21.15 BC: 300 lb Conc. Load at 8.50 BC: 122 lb Conc. Load at 9.15,11.15,13.15,15.15 17.15,19.15,21.15 Purlins ' In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 8.50 22.17 BC 68 0.00 22.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. 22'2" 713/1 y1 1y" 300r2 2 122# 2 122 21122# 2, 12 2 122 2 12 Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Sid: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): -0.226 C 999 361 8vq_RT(CL): 0.345 1 709 240 HORZ(LL): 0.060 B - - HORZ(TL): 0.103 B - Creep Factor: 2.0 Max TC CSI: 0.887 Max BC CSI: 0.990 Max Web CSI: 0.875 Wgt: 119.0 Ibs VIEW Ver: 20.01.01A.0724.12 T M 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL J 1838 /- /- /- /1316 /- K 1998 /- /- /- /1420 /- Wind reactions based on MWFRS J Brg Width = 8.0 Min Req = 1.5 K Brg Width = 8.0 Min Req = 1.7 Bearings J & K are a rigid surface. Bearings J & K require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 1318 - 2091 C - D 2593 - 3623 B - C 2577 -3528 D - E 2593 -3623 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. J -1 3286 - 2389 H - G 3301 - 2385 A - J 2023 -1260 G - F 33 - 30 1- H 3301 -2385 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C -1 292 0' G - E 3877 -2768 C - G 409 - 224 E - F 1417 -1794 D - G 1104 - 980 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building rode and TPI-1. The approval of the TDD and any field 4451 St. Lucie Blvd, Suite 201 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms areas defined in TPI-1. CnnvdnhtQ201fi A-1 Rnnf Tniasr_c- Renmdiidinn ofthis dnmunant. in anv form.N nmhihited without the written nanni inn of A-1 Rnnf Tni-n Job Truss Truss Type Qty Ply 02/09/2021 2598 CHHS3B CA JACK 8 1 t 12 4 B 2M(A1) A T 7-15/16" 3-155 6" X I C Loading Criteria (psf) Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.000 - 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.000 - - 240 B 35 /- /46 /25 132 /26 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.000 - - - C 21 /- /46 /11 /6 /39 EXP: C Kzt: NA Des Ld: 40.00 Plate Type(s): HORZ(TL):0:000 - - Wind reactions based on MWFRS Mean Height: 25.00 ft WAVE Creep Factor: 2.0 B Brg Width = 1.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TIC CSI: 0.021 C Br Width = 1.5 9 Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 Max BC CSI: 0.007 Maximum Top Chord Forces Per Ply (Ibs) C&C Dist a: 3.00 ft Max Web CSI: 0.000 Chords Tens.Comp. Loc. from endwall: Any Wgt: 4.21bs A - B 55 -131 GCpi: 0.18 Wind Duration: 1.60 VIEW V_ er: 20.01.01A.0724.12 Maximum Bot Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Top chord: 2x4 SP #2; A - C 156 -49 Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(!n oc) Start(ft) End(ft) BC 8 0.36 1.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes '•"` BEARING ANALOG MODIFIED! '•^`• a **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn responsibility for the design of the single Truss depicted on the TDD only, under TPI-,I. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, ir,the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for'general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. , r—riaht 95 2016 A-1 Rmf Tnt. se-s — Renrntludinn of this d—ment. in anv form. is nmhihited without the written na mission of A-1 Ronf Tnissec. Job CHHS3B Loading Criteria (psf) TOLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x6 SP #2; Truss Truss Type Qty Ply 02/09/2021 CJ3 JACK 8 1 12 4 F,--- C T III1.5X B X4(A1 HB 11-1/4" to A 3-15 16" 1 F E D 1113X6(*') SEAT PLATE REQ. f- -1r6" ---I �- 2'0-3/4" 11-1 /4" �- 3' Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Plating Notes (")1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 36 0.00 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 2599 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl U# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): 0.019 E 999 360 Loc R+ / R- / Rh / Rw / U / RL F 389 /- /- /321 /208 /73 Rep Factors Used: Yes VERT(CL): 0.037 E 661 240 FT/RT:10(0)/10(10) HORZ(LL): -0.006 C - - D - /-79 /- /59 /85 /- Plate Type(s): HORZ(TL): 0.013 C - - C - /-85 /- /41 /75 P WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.279 F Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.191 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.104 C Brg Width = 1.5 Min Req = - Bearing F is a rigid surface. Wgt: 11.9 Ibs Bearing F requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 20.01.01A.0724.12 Chords Tens.Comp. Chords Tens. Comp. A - B 75 -249 B - C 28 -40 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-E 288 -43 E-D 0 ' 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - E 674 - 237 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specially Engineer), the seal on any TDD represents an acceptance of the professional engineers responsibility for the design of the single Truss depleted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1. Cnnvdnht 0201e A-1 Roof To,.--Renrndodion of this done-ent. in am form. is nmhihifed withnut the wriman narmiacion of A-1 Roof Tniacnc, Ryan Bays, P.E. 491231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 Job CHHS3B Truss CJ5 Truss Type Qty Ply 02/09/2021 JACK 8 1 2600 Loading Criteria (psf) TOLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 3-15 16" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Sot chord: 2x4 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 60 0.00 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 12 C A L0 SEAT PLATE REQ. 1r6" 51 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code:FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.040 B 962 360 Loc R+ / R- / Rh / Rw / U / RL E 316 /- /- /233 /148 /122 Rep Factors Used: Yes VERT(CL): 0.032 B 999 240 FT/RT:10(0)/10(10) HORZ(LL): -0.026 B - - D 52 /- /- /28 1- Plate Type(s): HORZ(TL): 0.029 B - - C 76 /- /- /25 /100 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.576 E Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.235 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.190 C Brg Width = 1.5 Min Req = - Bearing E is.a rigid surface. Wgt: 21.7 Ibs Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 20.01.01A.0724.12 Chords Tens.Comp. Chords Tens. Comp. A - B 381 - 936 B - C 24 - 90 Maximum Sot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. E- D 0 0 A- E 993 - 335 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. E - B 908 -411 —WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the _ Ryan Bays, P.E. responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, localbuilding code and TPI-1. The approval of the TDD and any field 491231 use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Convrinht Q 2016 A•1 Rnnf Tmccr_c—Renraduntinn ofthis dmimont. in anv fnrn. is nmhihhed without the written nennic inn of A-1 Ronf Tri—, Job CHHS3B Truss CR Truss Type Qty I Ply 02/09/2021 JACK 4 1 2601 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(imoc) Start(ft) End(ft) BC 75 0.00 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. C SEAT PLATE REQ. II to 04 1 Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.121 B 516 360 Loc R+ / R- / Rh / Rw / U / RL E 381 P P /264 /188 /172 Rep Factors Used: Yes VERT(CL): 0.115 B 545 240 FT/RT:10(0)/10(10) HORZ(LL):-0.084 B - - D 92 P P /50 /4 P Plate Type(s): HORZ(TL): 0.094 B - - C 137 P P /52 /163 P WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.850 E Brg Width = 8.0 Min Req = 1.5 , Max BC CSI: 0.498 D Brg Width = 1.5 Min Req = - Max Web CSI: 0.255 C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Wgt: 27.3 Ibs Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 20.01.01A.0724.12 Chords Tens.Comp. Chords. Tens. Comp. A-B 475 -1214 B-C 43 -136 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. E- D 0 0 A- E 1257 -429 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. E - B 1156 - 529 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field d 91231 use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and . 4451 SL Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI.1. C—riaht 4 2016 A-1 RW Tnicsr-a — Ranmdurdinn of this domiment. in anv form. is nrnhihited vrithout the written nermi. Sinn of A-1 Rnaf Tins. Job CHHS3B Truss Truss Type Qty Ply HJ5 I HIP_ 12 11 02/09/2021 2606 4 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Lit Wedge: 2x6 SP #2; Special Loads 3-1516- 70# 38#+ 152# 2'0-3/16" --� 12 B SEAT PLATE REQ, 2'0-11 /16- --� 9'1-9/16" �- 1-5-1/2" -t- 2'9-15/16" 2'9-15/16" -� 42# 75# 104# Wind Criteria Wind Slid: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 --(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 2 plf at 0.00 to 2 plf at 9.13 BC: From 2 plf at 0.00 to 2 plf at 9.13 TC: 70 lb Conc. Load at 1.46 TC: -38 lb Conc. Load at 4.29 TC: 152 lb Conc. Load at 7.12 BC: 42 lb Conc. Load at 1.46 BC: -75 lb Conc. Load at 4.29 BC: 104 lb Conc. Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 9.13 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity Non -Gravity TPI Std: 2014 VERT(LL): -0.062 C 999 360 Loc R+ / R- / Rh / Rw / U / RL A 382 /- /- /- /371 /- Rep Factors Used: Varies by Ld C §Q6RT(CL): -0.064 C 999 240 FT/RT:10(0)/10(10) HORZ(LL): -0.083 C - - C 109 /- /- /- 148 /- Plate Type(s): -HORZ(TL): 0.084 C - - B 85 /- /- /- /156 1- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.704 A Brg Width =11.3 Min Req = 1.5 Max BC CSI: 0.626 C Brg Width = 1.5 Min Req = - Max Web CSI: 0.000 B Brg Width = 1.5 Min Req = - Bearing A is a rigid surface. Wgt: 32.2 Ibs Bearing A requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 20.01.01A.0724.12 11 Chords Tens.Comp. A - B 43 - 35 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 0 0 "WARNING•• Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in wdting.by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. ('.nnwioht 0 201E A-1 Ronf Tn,.-- Ranr d-linn of this dnarment, in anv An- le nmhihitad withnut the written mr tlr inn of A-1 Rant Tnimes. Job CHHS3B Loading Criteria (psf) TOLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Truss HJ8 70# i Truss Type HIP_ -38#+ SEAT PLATE REQ. �- 2'0-11 /16" Qty Ply 0210912021 2 1 152# 273# i- 2'0-3/16"--{ D 11'11-1/2° 1'5-1/�--/2' 2'9-15/16" ---2'9-15/16"---�-2'9-15/16" -7184 42# 104# Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 3.889' Special Loads --(Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25) TC: From 2 plf at 0.00 to 2 pif at 11.96 BC: From 2 plf at 0.00 to 2 plf.at 11.96 TC: 70 lb Conc. Load at 1.46- TC: -38 lb Conc. Load at 4.29 TC: 152 lb Conc. Load at 7.12 TC: 273 lb Conc. Load at 9.94 BC: 42 lb Conc. Load at 1.46 BC: -75 lb Conc. Load at 4.29 BC: 104 lb Conc. Load at 7.12 BC: 184 lb Conc. Load at 9.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 93 0.00 11.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Code / Misc Criteria . Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): -0.048 C 999 361 SA-ERT(CL): 0.054 C 999 241 HORZ(LL): -0.010 B - - HORZ(TL): 0.019 B - - Creep Factor: 2.0 Max TC CSI: 0.970 Max BC CSI: 0.989 Max Web CSI: 0.311 Wgt: 53.2 Ibs VIEW Ver. 20.01.01A.0724.12 T M r 1 2607 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL G 451 /- /- /- /493 P E 300 P /- P /223 P D 174 P P P /187 P Wind reactions based on MWFRS G Brg Width = 11.3 Min Req = 1.5 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Bearing G requires a seat plate. I Maximum Top Chord Forces Per Ply (Ibs) Chords Teils.Comp. Chords Tens. Comp. A-B 133 -214 C-D 76 -60 B - C 731 -482 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. G-F 465 -723 F-E 0 0 A - G 204 -120 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. G - B 655 -280 C - F 753 -485 **WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TOO, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TOO represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depleted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the # 91231 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPIA. Mnvrinht 0 201E A-1 Roof Tn- - RA --Arlin of this d=rmnnt. in anv form. Ic nmhibited with.d thn wntlnn nrnnletlnn of A-1 Rmf T.,-.,. Job CHHS3B Truss Truss Type Qty I Ply J7 I EJAC 17 1 02/09/2021 2603 Loading Criteria (psf) TCLL: 20.00 I TCDL: 10.00 BOLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " SEAT PLATE REQ. f --- 1'6" --{ Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; ,- Bot chord: 2x4 SP #2; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use puriins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 6.50 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. , Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE N 6'6" Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): -0.096 B 589 36( VERT(CL): 0.087 B 647 24( HORZ(LL): -0.066 B - - HORZ(TL): 0.074 B - - Creep Factor: 2.0 Max TC CSI: 0.718 Max BC CSI: 0.413 Max Web CSI: 0.238 Wgt: 25.9 Ibs VIEW Ver. 20.01.01A.0724.12 C T in L6 04 1 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL E 364 /- /- /255 /177 /159 D 82 /- /- 145 /4 /- C 122 /- /- /45 /147 /- Wind reactions based on MWFRS E Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 449 -1142 B - C 38 -126 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. E- D 0 0 A- E 1190 -403 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. E - B 1091 -497 "WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin responsibility for the design of the single Truss depicted an the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Ryan Bays, P.E. responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 91231 use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1. Cnnvriaht 02n16 A-1 Rmf Tm—Ranrnd,,dinn ofthis dnntment, in anv fnnn. Is nmhihhed wilhmit the written nanniminn of A-1 RnnfTni-es. Job CHHS3B Truss Truss Type J8 EJAC Qty Ply 02/09/2021 11 1 2604 Loading Criteria (psi) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " T 3-15116- SEAT PLATE REQ. �--- 1'6" ---+ I- 8,6" Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 :SP 2400f-2.OE + SP M-31:; Sot chord: 2x4 :SP 2400f-2.OE + SP M-31:; Lt Slider: 2x6 SP #2; block length = 2.750' Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 8.50 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE 0 Defl/CSI Criteria PP Deflection in loc Udefl L/# VERT(LL): -0.166 B 485 36( VERT(CL): 0.172 B 467 24( HORZ(LL): -0.116 B - - HORZ(TL): 0.130 B - - Creep Factor: 2.0 Max TC CSI: 0.592 Max BC CSI: 0.353 Max Web CSI: 0.298 Wgt: 34.3 Ibs VIEW Ver. 20.01.01A.0724.12 W ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL E 437 /- /- /292 /220 /209 D 122 P P /66 /5 P C 181 /- P /72 /210 P Wind reactions based on MWFRS E Brg Width = 8.0 Min Req,= 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing E is a rigid surface. Bearing E requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 581 -1470 B - C 57 -164 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords, Tens. Comp. E- D 0 0' A- E 1494 - 531 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. E - B 1395 - 654 -WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn P.E. , n Bays responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rya # Bays, responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field91231 use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. C nvdaht A 2016 A-1 Roof Tn­ — R"nroduntinn of this d—ment. in anv form. is nrnhihltrd vrithnut thn wdnnn onrmissinn of A-1 Roof TmcsPc. Job CHHS3B Truss J8B Truss Type Oty Ply 02/09/2021 MONO 1 1 2605 ). K Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " 3-1T6- Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 It Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Lt Slider: 2x6 SP #2; block length = 2.750' Plating Notes All plates are 2X4(C6) except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.00 8.50 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. u 69-7/16" 11'8-9/16" -- Code / Misc Criteria Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE 8'6" Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): -0.055 B 999 36( VERT(CL): 0.070 B 857 24( HORZ(LL): -0.038 B - - HORZ(TL): 0.047 B - - Creep Factor: 2.0 Max TC CSI: 0.557 Max BC CSI: 0.459 Max Web CSI: 0.304 Wgt: 37.1 Ibs VIEW Ver. 20.01.01A.0724.12 T co 1 ♦ Maximum Reactions (Ibs), or'=PLF Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL G 350 /- /- /245 /131 /148 H` 56 P P /29 /29 P Wind reactions based on MWFRS G Brg Width = 8.0 Min Req = 1.5 H Brg Width = 76.0 Min Req = - Bearings G & G are a rigid surface. Bearings G & G require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Camp. A- B 432 -1049 C- D 0 - 33 B - C 37 - 204 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. G-F 10 -26 F-E 0 0 A - G 1091 - 385 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. G - B 924 -487 C - F 640 -254 -WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form. verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless,othenvise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin Ryan Bays, P.E. responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the I # g1231 responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. NI notes set out In the TDD and the practices and 4451 St Lucie Blvd, Suite 201 guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946 Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I. Co- Mht 0 2016 A-1 Roof To— — Renroduolion of this domiment. In anv form. is nmhihitnd without thn wdttan nnnniscion of A-1 Roof Tn— 10/28/2020 HIP/ KING JACK (TYPICAL) STDL 01.0 ,A-1 ROOF = TRU55E9 A FLORIDACORPORATION A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 (772)40?-1010 ATTACH END JACKS USING (4) 0.131" O TOENAILS ATTOP CHORD & (3) 0.131" 0 TOE NAILS AT BOTTOM CHORD. ATTACH KING JACK USING (3) 0.131" 0 TOE NAILS AT TOP CHORD & BOTTOM CHORD.' ATTACH CORNER JACKS USING (2) 0.131" 0 TOE NAILS AT TOP & BOTTOM CHORDS (TYP). CORNERSET GENERAL SPECIFICATIONS: MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60' MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 5/28/2020 HIP/ KING JACK (HVHZ) STDL 02.1 '0914A-1 R®OF 0== TRUSSES A FLORIDA CORPORATION A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL. 34946 (772)409-1010 ATTACH KING & END JACK WITH (1) THJA26 HANGER OR EQUIVALENT AT BOTTOM CHORD ATTACH KING & END JACKS WITH (1) LSTA12 TWIST STRAP AT TOP CHORD WITH (10) 1Od NAILS PER STRAP (MIN.) & (3) 0.131" 0 TOE NAILS. ATTACH CORNER JACKS & STD. JACKS WITH (1) LSTA12 TWIST STRAP AT TOP CHORD & BOTTOM CHORD WITH (10) 1 Od NAILS PER STRAP MINIMUM (TYP). HIGH VELOCITY HURRICANE ZONE CORNERSET SPECIFICATIONS: MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60' MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT. NOTE: IN ADDITION TO STRAPPING TOE- NAIL BOTH CHORDS OF CORNER JACKS TO CARRYING MEMBER PER THE FOLLOWING SCHEDULE: • 2X4: (2) 0.131" 0 TOE NAILS • 2X6: (3) 0.131" 0 TOE NAILS LSTA12 TWIST STRAP WITH 1 OD NAILS, MIN. (10). SEE MFR'S RECOMMENDED CONNECTION. HIP, OR KING JACK (TYP.) JACK, OR CORNER JACK (TYP.) IMPORTANT NOTE: CONNECTION DESIGNED IN ACCORDANCE WITH FBC 2321.6- 2321.7 PROVIDING METAL STRAPPING (FLORIDA APPROVED PRODUCT) TO RESIST MIN. 700LB UPLIFT AT ALL CONNECTIONS IN HIGH VELOCITY HURRICANE ZONE. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 I ALTERNATE GABLE END BRACING DETAIL I STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD V-3'MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE SLOG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES @ F 24' O.C. 2XG DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). / PROVIDE 2X4 BLOCKING BETWEEN < THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \ EITHER SIDE AS NOTED. TOENAIL BLOCKING TO TRUSSES WITH (2) - �, 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH r� (5) - 10d COMMON WIRE NAILS. CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES ( STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED G' O.C. - FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM). STRUCTURAL GABLE TRUST MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIDR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED / STUDS. TRUSSES WITHOUT INLAYED \S ARE NOT ADDRESSED HERE. / STANDARD GABLE / \SS / UKAL TRUSS .,.�.. , 3TUD AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. Ryan Bays, P.E. it 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 12/23/19 PIGGY -BACK TRUSS STDTL04.f A-1 ROOF TRUSSES 4451 ST: LUCIE BLVD. FORT PIERCE, FL 34946 . 772-409-1010 PIGGY -BACK DETAIL (TYPICAL) 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. OR... 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. **REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE TRUSS SPECIFICATIONS.** PIGGY -BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) 2'-0" MAX OPTION NO. 1 - TEE-LOK 3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH ,6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8" TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2 PLATES) . OPTION NO.2 - APA RATED GUSSET: 8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO.3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION #1: TEE-LOK MULTI -USE CONNECTION PLATE. OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURL'IN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24" O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. ** IMPORTANT NOTE ** THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 V JULY 17, 2017 TRUSSED VALLEY SET DETAIL - SHEATHED STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 VALLEY TRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6" O.C. GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL "A". 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS - 01. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. TRUSS, OR GIRDER TRUSS DETAIL A BASE TRUSSES _C CINU, UUIv11vIU1V 'S, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF - ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.C. (BASE AND VALLEY) SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. SIMPSON SDS25412 (1/4" X 4.5") OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 5, 2018 1 TRUSSED VALLEY SET DETAIL I STDTL016 ` Y s GENERAL SPECIFICATIONS: 1. NAIL SIZE= 3"X 0.131"= 10d 2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL �. 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. i 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01. 4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. FORT PIERCE, FL 34946 TRUSS, OR GIRDER 772-409-1010 TRUSS H 1' II II I I II I II 11 II �1 rillI' I' II II V I' I 1 II II 1' 1 VALLEY TRUSS li BASE TRUSSES (TYPICAL) II '' it II II II SECURE WIC IJL 1 AIIL A (NO SHEATHING) N.T.S. GABLE END, COMMON TRUSS, OR GIRDER P F 12 VALLEY TRUSS TRUSS / (TYPICAL) SEE DETAIL "A" BELOW (TYP.) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/ TWO MAX SPACING = 24" O.C. (BASE AND VALLEY) SIMPSON SDS25300 (1/4" X 3") MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Ryan Bays, P.E. # 91231 4451 St. Lurie Blvd, Suite 201 Fort Pierce, FL 34946 J U LY 17, 2017 A. 1 1\V%J%.71LL.J V!1LLL 1 %JL— 1 LJL 1 P11L (HIGH WIND VELOCITY) I STDTL07 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ATTA( WIND DESIGN PER ASCE 7-98, ASCE 7- WIND DESIGN PER ASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24" O.C. (BASE AND VP SUPPORTING TRUSSES DIRECTLY UNGr=rc VMLLr=r 1 RUOOGO MUO I Dr - DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. CLIP MAY BE APPLIED TO THIS FACE UP TO A NON -BEVELED MAXIMUM 6/12 PITCH BOTTOM CHORD H I r FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MUST BE APPLIE THIS FACE WHEN I EXCEEDS 6/12 (MAX 12/12 PITCH) Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL 1 STDTL08 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS 7z; VERT STUD SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. VERTICAL 2X6 SP OR SPF STUD #2 DIAGONAL BRACE (4) - 16d NAILS 16d NAILS SPACED G' O.C. (2) 10d NAILS INTO 2X6 2X6 SP OR SPF #2 2X4 SP OR SPF #2 TYPICAL HORIZONTAL BRACE NAILED TO 2X4 VERTICALS SECTION A -A W/(4) - 10d NAILS DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES * WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS / ** (4) Bd NAILS MINIMUM, ROOF 3X4= PLYWOOD SHEATHING TO SHEATHING B 2X4 STD SPF BLOCK *jDIAGONAL BRACING ** L - BRACING REFER / REFER TO SECTION A -A TO SECTION B-B 24- MAX. -►I / / NOTE: 1. TMINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. (2) - lOd 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO 12' MAX. NAILS BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. -- ARCHITECTIOR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR / BETTER WITH ONE ROW OF 10d NAILS SPACED G' D.C. TRUSSES @ 24' D.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM / AT 4' - 0. O.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED G' O.C. HORIZONTAL BRACE TO BE LOCATED AT SPACED 48' D.C. ATTACHED THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE __, TO VERTICAL WITH (4) - STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) ;'' 16d NAILS, AND ATTACHED 7. GABLE STUD DEFLECTION MEETS OR EXCEEEOS L/240. DIAG. TO BLOCKING WITH (5) - BRACE B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. lOd NAILS. 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10.10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X3-9' COMMON WIRE NAILS HORIZONTAL BRACE RESPECTIVELY. (SEE SECTION A -A) 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. • END WALL MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL AT BRACES T 1/3 POINTS MAXIMUM STUD LENGTH 2X4SP#31STUD 12"0.C. 3.8.10 5-6-11 6-6-11 11-1-13 2X4 SP 43 / STUD 16" O.C. 3-3-10 4-9-12 6-6-11 9.10-15 2X4SP#31STUD 24"0.C. 2-8-6 3-11-3 54-12 8-1-2, 2X4 SP #2 12" O.C. 3-10-15 5-6-11 6-6-11 11-8-14 2X4 SP #2 16" O.C. 3.6-11 4-9-12 6-6-11 10-8-0 2X4 SP #2 24" O.C. 1 3-1-4 1 3.11.3 1 6-2-9 , 9-3-13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - G' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER SOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C ASCE 7.10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. I t* FEBRUARY 17, 2017 I T WIITH 2XIBRACE ON Y IL STDTL09 f ES: LACING / I-BRACING_TO BE USED WHEN CONTINUOUS LATERAL BRAI MPRACTICAL. T-BRACE / I -BRACE MUST COVER 907 OF WEB LENG DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS fINUOUS, LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2X8 10d 6' O.C. NOTE- NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON TWO-PLY TRUSSES NAIL TO BOTH PLIES) NAILS t SPACING } k � } i-- T-BRACE BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 20 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE T-BRACE / I -BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS NAILS WEB NAILS WEB I -BRACE T-BRACE Ryan Bays, P.E. # 91231 SECTION DETAIL 44 5 Fort PiereeBFL'34946201 FEBRUARY 17, 2017 I LATERAL BRACING RECOMMENDATIONS I STDTL1l a TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET ALONG A FLOOR TRUSS. NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (OD NOT USE METAL FRAMING ATTACH TD VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO ATTACH WEB WITH (3) — 10d SCAB WITH (3) — 10d TO TOP CHORD NAILS (0.131' X 3') NAILS (0,131' X 3'). I ATTACH TO VERTICAL WEB WITH (NAILS (0 313)X 3') BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) — 10d TO BOTTOM CHORD NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) — 10d NAILS (0.131' X 3') IN EACH CHORD ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIA.) ATTACH TO VERTICAL INSERT SCREW THROUGH SCAB WITH (3) — 10d OUTSIDE FACE OF CHORD INTO NAILS (0.131' X 3') EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) TRUSS 2X6 4' — 0' WALL BLOCKING STRONGBACK (TYPICAL SPLICE) (BY OTHERS) (BY OTHERS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS- NECESSARY, USE A 4' — 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) — 10d NAILS (0.131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' — 0' AND FASTEN WITH (12) — Ryan Bays, P.E. 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY #91231 WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 FEBRUARY 17, 2017 LATERAL TOE -NAIL DETAIL, STDTL11 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772.409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 13. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 o .135 93.5 85.6 74.2 72.6 63.4 J .162 108.8 99.6 86.4 84.5 73.8 ri .128 74.2 67.9 58.9 57.6 50.3 c3 .131 75.9 69.5 60.3 59.0 51.1 Z 0 J .148 81.4 74.5 64.6 63.2 52.5 in N M THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. SIDE VIEW APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. �2X4) 3 NAILS EXAMPLE: NEAR SIDE (3) - 16d NAILS (0162' DIA. X 3V) WITH SPF SPECIES BOTTOM CHORD 4­4 NEAR SIDE FOR LOAD DURATION INCREASE OF 115: 3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY NEAR SIDE ANGLE MAY VARY FROM 30' TO 60' 45.00' ANGLE MAY VARY FROM 30° TO 60' 45.00' SIDE VIEW (2X6) 4 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE 000 E. .u, Su9ite 201 uFort Pierce, F 3446 FEBRUARY 17, 2017 UPLIFT TOE -NAIL DETAIL STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF-S 0 .131 59 46 32 30 20 Z O J .135 60 48 33 30 20 .162 72 58 39 37 25 J 2 .128 54 42 28 27 19 Z Z JO .131 55 43 29 28, 19 W .148 62 48 34 31 21 J Lo J_ N Q M Z .120 51 39 27 26 17 CD Z .128 49 38 26 25 17 O 131 51 39 27 26 17 148 57 44 31 28 20 M NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE FOR WIND DOL OF 1.33: 3'(NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 1.60 (OOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY,A DIFFERENT CONNECTION. +�+ USE (3) TOE -NAILS ON 2X4 BEARING WALL USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR Sl )E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY IL NAIL NAIL ..ru„ Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fart Pierce, FL 34946 SIDE VIEW END VIEW F�BRIUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT STDTLI3 A-1 ROOF TRUSSES _ 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 1.0 x _1+ J 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf. Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 TYPICAL ALTERNATE BRACING DETAIL T ` April 11, 2016 STDTLI4 FO EXTERIOR FLAT GIRDER TRUSS A-1 ROOF TRUSSES 4451 ST. LUCIEBLVD, FORT PIERCE, FL 34946 772-40971010 (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 .VARIES J (4) 12d MAX 3011(2'-611) 2x6 #2 SP (Both Faces) 2411 O.C. SIMPSON H5 Rvan Rays_ P F # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 84 * STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND FEBRUARY 17, 2017 1 DAMAGED OR MISSING CHORD SPLICE PLATES STDTL15 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD., FORT PIERCE, FL 34946 772-409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK X (INCHES) MAXIMUM FORCE (LBS) 157. LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24" 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30' 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42' 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48" 3657 5485 3346 5019 2829 4243 2898 4347 * DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C • 10d NAILS NEAR SIDE +10d NAILS FAR SIDE N114 X� BREAK } X' MIN [--*- 6' MIN TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THE -LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT -(SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR 'DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN J THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID Ryan Bays, P.E. UNUSUAL SPLITTING OF THE WOOD. 1191231 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID 4451 St. Lucie Blvd, Suite 201 LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. Fort Pierce, FL 34946 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. G. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. FEBRUARY 17, 2017 I SCAB APPLIED OVERHANGS STDTL16 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34M 772-409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 115 SPACING: 24' D.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END BEARING CONDITION NOTES: 1. ATTACH 2X_SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.14B' DIA. X 3') SPACED 6' D.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT,WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES Ryan Bays, P.E. # 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946