Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1928 Lynx Drive Permit Documents
a� Brian Pearl °uf �. Installation Sales and Service Order (SSO) I 5r. Territory Sales Representative 3111I 5075 US1 Vero Beach FL 32967 C:772.633-0740 i LP0434 Brion.Peart@amerigas.com Date: 10/26121 Customer Name: Ve Cusi am Homes CM Installation Address: Cittt: lZipcoctat 1928 EM Drive Fort Fierce FL $UUngAddrass city. stater'Ip;Code FL Cell Number: lRome Number Email Address: SCOPE OF WORK Bury 500 gallon tank left rear of house 10 It away fromPL and h, use run line to BBQ, fire pit and house stub. Inside gas lines to WIL stove and dryer by builder. Gas hook up's for insi&applianceswill be extra'if needed, MATERIALS To BE USED Sea below EST. START DATE.. - EST. COMPLETION DATE PAYMENTAND CREDITTERMS 50% Deposit required before any work or permitting begins. Work wilt be bitted as job progresses; Any amounts billed; exceeding deposit, will be due aOdays from Invoice, with approved credit. Absent credit approval, 100% payment re ulred in advance. CITY DESCRIPTION ' LINE TOTAL 400 Propane 1173.74 1 500 anon tank J1295 2II69 i B and anchor tank with anode 129 3 Transitions -... - ... US atgrs 270' 130 314 Poly will bill actual)9 1170 3 Gashook`u 's BQ, Fire git andhouse stuff 195 585 4 Shutoff' 25 100 2 Bard riser 145 290 1 Backyard dirt removal 300 30Q'' 2 Tees 135 270 FORT PIERCE Permit Fees 200 200 This is a contract for the goods and work named, subject to the attached Terms and Conditions. You may cancel this SUbTotall $8847.74 contract before midnight ofthe third business day after the date on which You signed below by calling 1-800- SalesTax7.0% $605.34 AMERIGAS unless, daring this time period AmeriGas performed all or part of the Work requested. To acceptthls RropaneTax 0.D% 0e00 contract, including the attached Terms and Conditions, sign here and return: Proposed Total $9453,08 Customer Name: {,. � I�S } j� 1 ignature: f U _. Pate; ll �rtw 90010314.12 Valid for 80-days O'T`ICE OF CONEWENCEWNT Permit No, Z101-015pw Property Tax ID No. 4'�5 ';i' i003is xo State of Florida, County of St. Lucie The Undersigned hereby gives notice that improvement will be made to certain: real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Legal Description of propel and address if General Address 2� -F 1 1 /1_0r I Interest in property. Fee Simple Title bolder (if other than owner) Phone # Surety N �' �r ,-5D-1-)Q0 MICHELLE R. MILLER CLERK OF THE.CIRCT COURT Address FAINT LUCIE COUNTY FILE# 489705607720no210320:0o: PM. Amount Of Bond OR BOOK 4661 PAGE 1893-1893 Dao Type .NG RECORDING; $10,00 Lender t,i ) A - Address Persons within the State of Florida destgnatedby Owner upon whom notices or other documents -maybe served as provided by Section 713.13 (a) 7, Florida Statnes:: Name iV l &T/ Phone# Address Fox # In addition to himself, owner Phone # Fax # to receive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b), Florlda Statutes, Expiration date of notice of Commencement is one year from the date of recording unless a different date Is specified. WARNING TO OWNER. ANY PAYMENTS MADE BY TIE: OWNER AFTER THI1 EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CH 7i3.13, F;S., AND CAN RFSULT IN YOUR PAYNG TWICE FOR IMPROVEMENTS TO YOURTROPERTY.. A NOTICE OF COMMENCEMENT MUSTBE RECORDED AND POSTED ON THE JOB SFTEBEFORE'THE FIRST INSPECTION. IFYOU INTBNDTO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN TO NBY BEFORE COO NC7VORIC OR RECORDING YOUR NOTICE OF COMMENCMENT• //11!!// 1, County before in me Title: Notary Public Commise f, x kid A ng b "4x s. a i ■ Corrugated stainless steel tubing (CSST) gas piping systems will be bonded in accordance with Section G2411.1(310) of theFlorida Building Code and NFPA 54. ■ Underground gas piping will be installed at a minimum depth of 12 inches below grade in accordance with Section G2415.12 (404.12) of the Florida Building Code and NFPA 58. ■ Polyethylene pipe will be installed in accordancewith 6.11.4 of NFPA 58 and the Florida Building Code. ■ Carbon monoxide monitors will be installed prior to inspection and will meet all code and safety requirements of NFPA 54 and the Florida Building Code. Copyright 2017 National Fire Protection Association (NFPMa. Licensed, by agreement, for individual use and download on l V31I201] to AmenGas for designated user Brian Pend. No other reproduction or transmission in any form permitted without written petmiasion of NFPA®. For inquires or to report unauthorized use, contact Ilcensing@nfpa.mg. Chapter 16 • Pipe and Tubing Sizing Tables TABLE 16.1(n) i'alyei/iytene= ?lprir #irpe--!i'S Gas: Undiluted Propane Inlet Pressure: 10.0prig Pressure Drop: I.O psig Speeifio Gravity: 1.52 . Plastic Pipe 'k in. % in. 1 in. I r/, in. 11/: in. 2 in. Lengtle SDR 9.33 SDR 11 SDR 11 SDR 11 SDR 11 SDR 11 (0.660) (0.860) (1.007) (1.328) (1.554) (1.943) 0, Pressure liggtYfa$arn�XEcaatf SYttRe (Law PresstrrEJ Rugzrlaar_ ,1, . 30 2140 2390 7740 13420 20300 36400 40 1840 3670 6630 11480 17300 31200 50 1630 _ 3260 5870 10180 15400 27600 60 1470 2950 5320 9220 13900 25000 70 1360 2710 4900 8480 12800 23000 80 1260 - 2530 4560 - 7890 11900 21400 90 1180 2370 4270 7400 11200 20100 100 1120 2240 4040 6990 10600 19000 125 - 990 990 3580 6200 9360 16800 150 897 897 3240 5620 8480 15200 175 826 826 2980 5170 7800 14000 200 778 778 2780 4810 7260 13000 225 721 721 2600 4510 6910 12200 250 681 681 2460 4260 6430 11600 275 646 646. 2340 4050 6110 11000 300 617 617 2230 3860 5830 10470 350 567 567 2050 3550 5360 9640 400 528 528 1910 3300 4990 8970 430 495 495 992 3100 4680 8410 500 468 468 937 2930 4420 7950 600 424 424 849 2650 4010 7200 700 390 390 781 2440 3690 6620 800 363 363 726 2270 3430 6160 900 340 340 682 2130 3220 5780 1000 322 322 - 644 2010 3040 5460 1500 258 258 517 933 1616 4390 2000 221 221 443 498 1393 - 3750 IPS: lion Pipe Size. SDR: Standard Dimension Ratio Notes: (1) Capacities are in 1000 Pal C) Dimensions in parentheses are inside diameter. 2017 Lid Gas Code Handbook Compact First Stage Regulators LV3403TR Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring up to 1,500,000 BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. ' Maximum Now based on Inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20%lower than the regulator setting and delivery pressure 20% lower then the settng. Provides accurate first stage regulation in two -stage bulk tank - ea systems. Reduce tank pressure to an intermediate. pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like industrial furnaces or boilers. Also incorporated In multiple cylinder installations. - LVanuabrca ++/z' F. LV4403TR4 NPT '/z" F LV4403SR9 NPT LV4403TR9 F. POL �V4403SR96 a�"5 1 5 LV4403TR96 F.NPT 10 5-10 Yes 1 2,500,000 • When used for final stage pressure control, must either incorporate Integral relief valve or separate relief valve should be specified in accordance with NFPA Pamphlet 56. Maximum taw based on Inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20 % lower than the setting. Low Pressure Second Stage Regulators - Standard Settings LV4403B Series Designed to reduce first stage pressure of 5 to 20 PSIG down to eas a, burner pressure, normally 11" w.c. Ideal for medium commercial �L installations, multiple cylinder installations and normal domestic loads. LV440384 I I %,, LV44031346 %' F. NPT 11" W.c. at LV4403846R' #28 9"to 13" a Drill 10 PSIG we Over Inlet /°" F. NPT LV4403e66 Inlet %'F. NPT `aackmount design Maximum tow based on 10 PSIG inlet and T w.c. delivery pressure. 935,000 LV3403TR LV4403Sedes LV4403311121erles 6 regoproducts.com 1 336.449.7707 Ar .W7 lrm& .. iet New Compact "Back -Mount" Regulator LV3403BR Series The LV3403BR Back Mount Regulator is designed to reduce first nns�a stage pressure of 5-10 PSIG down to burner pressure normally 11" B` w.c. Designed as a second stage regulator for smaller applications with flow requirements up to 450,000 BTU/hr. and are Ideal for homes, mobile homes, and cottages. +/; /�' F.NPT/3z, 11" w.c. At 10 9" to 13" Over Inlet F.NPT/;' FNPT PSIG Inlet W.C. aged on 10 PSIG inlet and 9" w.c. delivery pressure. n r ri+a t, 'r, �i :, The LV3403B4 is designed to reduce first stage pressure of 5-20 PSIG down to burner pressure normally 11" w.c. Designed as a %Wl second stage regulator for smaller applications with flow requirements up to 450,000 BTU'sthr, they are ideal for homes, mobile homes, and cottages. F.NPT I /" F.NPT' r 11"w.c.At 10 g„act 3„ PSIG Inlet LV340384V9 Maximum flnw haled nn 10 PSIG Inlet 9" w r.. dalivary nressurs Lowy Pressure Second Stage Regulators LV4403866RA Series Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally. 11" w.c. Ideal for medium commercial installations, vapor meter installations and normal domestic loads. O1p611ny xi 450,000 460,000 LV4403866RA 11" W.c. at 9" to 13" Over /a" F. NPT /a" F. NPT 3/16" 10 PSIG 1,000,000 LV4403866RA8•' Inlet W.C. Inlet -Maximum flow Is based on 1a PSIG Inlet and 9" w.c. delivery pressure ••Mounting Bracket Included. Low Pressure Second Stage Regulators - Standard Settings LV5503B Series Designed to reduce first stage pressure of 5 to 20 PSIG down to nusie burner pressure,normally it" w.c. Ideal for larger commercial and industrial applications, multiple cylinder installations and large domestic systems. LV550384 1 Ya" F. NPT 3/" F. NPT /1" 11" W.C. at 10 9" - 13" 1,600,000 LV5503B6 PSIG Inlet W.C. Over Inlet LV5503138 '/a" F. NPT 1" F. NPT °hf 2,300,000 laximum flaw Is based on 10 PSIG Inlet and 9' w.c. delivery pressure LV3403BRSeries LV34036411edes 11 ter/Mounting Bracket LV44031366RASeries LV55038Series 8 regoproducts.com 1 336.449.7707 7/16" GALV. CABLE (2)HDG CLAMPS ANCHOR (PULLED GHT). :LICAL ANCHORS '8"X40" SINGLE 6" HELIX 2 2"X30" SINGLE 4" HELIX HELICAL ANCHOR NOTE: 2 PAIRS 147,5#/ANCHOR 7/32, 7x19 GALV. CABLE 5500# . BREAKING STRENGTH W/(2)HDG CLAMPS TC ANCHOR (PULLED TIGHT) CABLE SHALL BE COATED, SLEEVED OR HAVE 1 LAYER 30# FELT AGAINST TANK 500 GALLON UNDERGROUND HOLD DOWN DETAIL GENERAL NOTES: 1. HELICAL ANCHORS. SHALL HAVE A PULL-OUT CAPACITY AS SHOWN. ANCHORS SHALL BE INSTALLED PER ANCHOR MANUFACTURER TO ACHIEVE STATED LOAD CAPACITY. CAPACITY VARIES WITH SOIL TYPE. VERIFY ANCHOR CAPACITY WITH SOIL TYPE ENCOUNTERED. 2,CHECK FOR UNDERGROUND UTILITIES PRIOR TO ANCHOR INSTALLATION 3. LOCATION OF TANK RELATIVE TO ADJACENT STRUCTURES AND FEATURES ARE DEPENDENT UPON LOCAL CODES AND IS THE RESPONSIBILITY OF OTHERS. 4, THE TANK AS SHOWN HAS BEEN DESIGNED TO PREVENT FLOTATION, COLLAPSE, OR LATERAL MOVEMENT DURING THE BASE FLOOD EVENT CONTRACTOR TO LOAD TEST 4" ANCHORS AFTER INSTALLATION �C ENSF�:y�'.� o 40111 :rr STATE OF 0 Q`: 1�';Z�,t © COPYRIGHT 2018 — FARLgY ENGINEERING, LLC 40RQ) N 111111111 t�?``,, AMERICAS FARLE Consulting E9NGINEERINGe oaC 2019-03-18 8800 N. U.S. p1, Suite #2 , Sebastian, Florida 32958 (772) 589.6229 (772) 589.2296 fax ARCOS.A TANK WIDTH GENERAL SPECIFICATIONS FLOAT ANODE 6VAGE CONNECTION Conforms to the latest edition and addenda of the ASME code for FILLER Pressure Vessels, Section VIII, Division 1. Complies with NFPA 58. VALVE 0 Rated at 250 psig from -202 F. to 125° F. All tanks may be O evacuated to a full (14.7 psi) vacuum. SERVICE/ NAME Vessel Finish: Coated with epoxy and red powder. (Tanks coated MULnvALVE �. PLATE with the epoxy powder must be buried). For Aboveground use, —" tanks will be coated with ArcClad, zinc rich epoxy primer and RELIEF VALVE super durable TGIC polyester topcoat. `Applicable federal, state, or local regulations may contain specific requirements for protective coatings and cathodic protection. The purchaser and installer are responsible for compliance with all federal state, local and NFPA Industry regulations. Cathodic protection is required and coating must be continuous and uninterrupted and must comply with local, state or national code. Quality Water Outside Head Overall Overall Leg Leg Weight Full Per Capacity -Diameter- Type Length Height Width Spacing Load Stack 120 wg. 24" Ellip 5' - 513/16" 3' - 3/1V 101/8" 3' - 0" 245 Ids. 96 12 454.2L 609.6 mm 1,671.6 mm 919.1 mm 257.2 mm 914A mm 111.1 kg. - 250 w9. 31.5" Hem! 7' - 21/2" 3' - 711/16" 12 3/4" 3' - 6" 472 lbs, 63 9 946.3 L 800.1 mm - 2,197.1 mm 1 1.109.6 mm 323.9 mm 1,066.8 mm 214.1 kg. 320 wg.- 31.5" Hemi 8' -11 3/4" 3' - 711/16" 12 3/4" 4' - 01/4" 588 lbs. 45 9 1,211.2 L 800.1 mm 2,736.9 mm 1,109.6 mm 323.9 mm 1,225.6 mm 266.7 kg. 500 wg. 3T42" Hemi 9' -10" 4' -1 5/8" 15" 5' - 0" 871 Ids. 30 6 1,892.5 L 950.5 mm 2,997.2 mm 1,260.4 mm 381.0 mm 1,524.0 mm 395.1 kg 1000 wg. 40.96" Hemi 15'-1013/16" 4' - 5 3/16" 161/4" 9' - 0" 1,729 Ibs 15 5 3,785.0 L 1,040.4 mm 4,846.6 mm 1,350.9 mm 412.8 mm 2,743.2 mm 784.3 kg. All vessels dimensions are approximate. For more information 888.558.8265 Eng. upaace: Hprn o, cuio