HomeMy WebLinkAboutProduct CertificationSave over $750 per year on energy
costs with the VS FloPro'" 1.65 HP
Variable -Speed Pump'
VS FloPro 1.65 is designed with an innovative adjustable base,
allowing for simple installation on new construction, or quick and
easy replacement of existing pumps. Well suited for applications
with 1.5" or 2" plumbing, the VS FloPro is designed to be
operated at energy -saving lower speeds for maximum efficiency.
• -115v and 230v Models Available
The VS FloPro is available in 230v and 115v models,
providing installation flexibility while avoiding time
consuming and costly rewiring expenses.
• Ultra High -Efficiency Motar
Features a totally enclosed fan -cooled (TEFC)
.permanent magnet brushless DC motor for
cooler operation and extended motor life.
• Multiple Control sy— Ift &%
Options Availahlez
The AUT model Is completely
programmable and customizable
with the Jandy AquaLink® line
of automation systems;'`and
can be paired with iQP6.fy1P01
for iAquaLink'" anytime,
anywhere app contrbU�,:y
The JEP model featuresan
onboard JEP-R controlled with two timed speeds/8
speeds total and can be rotated 180' or removed for
remote mounting. Reliable battery backup ensures
time and settings are sto'r'ed during power outages.
• Compact e
> High-performance=pump in, an ultra -compact.
body that easily fits in small equipment areas.
• Additional Features
> Adjustable base included with all FloPro models'
> Includes 2" unions or utilize 2" internal threads
> Ergonomic easy -transport handle
> High profile easy -grip lid handles
with large capacity basket
• Complies with Appliance Efficiency Standards
(CEC Title 20 & ANSI®/APSP-151 and qualifies
for power rebates, where offered.
Jandy.com 1 1.800.822.7933
Al y ;: Yr .Z Ci r li te. J
J...; d_ ts...n:. Allrrr 3i 1JK2 miter P ."r:t h.rrs c:� c°y�?3r
AD 6ll5:TABLE,BASE CONFIGURATIONS'
Base Fits Dimension Dimension
No Base Hayward °Super Pump°. Pentair° 73/4' 12.3/4'
SuperFlo°, Sta-Rita° SuperMaxI
Small Base Hayward Super II", Jandy PlusHP B 7/8- 13 7/8"
and MaxHP Pumps
Small Base Pentair WhisperFlo°, Sta-Rite Dyna-Glas"' 9 1/8" 14 1/8-
w/ Spacers
Small Base Sta-Rite Max-E Pro'. Sta-Rite Dura-Glas`'', - 10 3/4" 15 3/4'
& Large Base Sta-Rite Dura-Glas II, Sta-Rile Max-E Glas
b3M3E_NSiONS
Bpll Holes, Center to Center Rant Edge of Pump to Center of Bolt Hales
Max Union Rec. Carton Overall
Model No. THP WEFT Voltage
Watts Amps Size Pipe Size Weight Length
'VSFHP165JEP
VSFHP165AU165 9.11B 230VAC
1,600W 10.5 2"x2" 11/2-21/2" 46lbs 24"
VSFHP08SAUT VSFHP085AU0.85 11.900 115VAC
975 W 10.0 2" x 2" 1 1/2 - 2" 46 lbs 24'
VS FloPro
0.85 HP and 2.65 HP Performance Curves
eo-.
- -- •---------------
•
z.... L_.-_._ {_......
— — VSFHP08 { 15V)
s1 �
o
_.
y...._..,...
j 3450 RPM (
( ---V5FHP165 (230v) I
_ 40
7_._.--4..____-.._C__—..__.......-
) l
2400 PM
t r
�
l
`.�.1�_..-....._.....-!_.
:
;
z0
4730-F1PM._....�......__...j�
.._....._......-,3�...._...{....___.._�-.._.._i____.�.�._._!_.—..._
10 3
J.200 .M_......:
D
600 RPM-
n io 20 -.r 30
So i,v 70 60 So V" 110 120 130 4C
How Rate, Gallons Per Minute (GPM)
i ir•,,r({= 50:. t:J ` 3r' s art' S'f E�_i:.`++i m'idEl `'ifC.'tr^y a .' ).�f,::: yar Iun r�::i :}i::', : r:i'r�i.ti'c •,`..*r E] f a: .?3C2
7U C
1r,:.icG:^ace^.rdant-c:it ..?i"apnlie:a:{,+repair::r:,::?ls ,` 13..,
1 .F ' �•
')polar:: J6--ri carlr� the:• inclvice0 v: iti; JE? n;cda ,.-ontrctar c;l!cr: s?IC scaar ry � r.•rh A.' i rn0 _? �.
_rrna:° acj'rtat:=> or.;a Nit?r srxcr, itclua=_c:: i!i; al 9'i='oPra nodsir. L.a yc name �. ^.nlinral ,r:d>old
ah:4)4lJE9 tarP eitpF:j dnd
al;4�Vh':'tiE �oa ,tryst. aasc2 nar:'r �'�
f d f'a m. r oar rx 4r r i d „ur���s
a r - . .. po,, u,;, trtr yer :r ^s:,t .: c,er 1) T'f a''
Intertek
Da3 ndy
--3;,>
MAXIMUM EFFICIENCY.
ULTRA COMPACT DESIGN..
ufacturer Specification
- Load Test
The testing results provided by: American Test Labs of South Florida and Nutting Engineers of Florida
Testing and Consulting Services. Testing report-ATL report #0808.03-03 in conjunction with Baby Guard
Inc.
The sample below was tested by pull testing horizontally 36" from base with accu- force 250 force
gauges, s/n 62988075 X-Pole 64.4 with .063 aluminum extrusion pole.
Baby Guard mesh tested tensile strength ASTM D GRAB METHOD @ 157 LBS. BURSTING STRENGTH
MULLEN TESTER ASTM D 5034 D, 3786 and,g 53 @ 257 LBS.
Completed pool fence is assembled with x-pole and Baby Guard mesh tensioned between x-poles,
comprising of 6 poles per 15ft. section. Poles inserted with plastic composite sleeves into pool decking
[i.e.: sand set pavers, concrete, wood) and sections connected with safety connectors. The product
completely assembled and installed will withstand 321.4 LBS burst. Alt mesh has a minimum of 90%
transparency.
**In compliance with ASTM standard F-2286-05 **Florida building code 2017, 454.2.17.1.1,
454.2.17.1.2, 454.2.17.1.3,17.1.4, 454.2.17.1.5, 454.2.17.1.6„ 454.2.17.1.7, 454.2.17.1.8,
454.2.17.1.9, 454.2.17.1.10, 454.2.17.1.11, 454.2.17.1.12, 454.2.17.1.13, 454.2.17.1.14,
compliance with Florida Building code #515.29 pool barrier 2016
** In compliance with California code 1159920-115929
** Minimum fence height is 48" **Fence will be installed a.minimum of 20" off pool edge
Pemkanent mount diagram for Pool Safety Fencein compliance with
building code #615.29 and R 1101.1T.1.15.0A
1 Ineh rourM post
pole and deck
Deck level
to
Hex screw to fasten
L-Bracket to pole and deck
PG DAPT-2 Manual 021115:1-ayout 1 2/12115 12:15 PM Page 1
When the S-voft battery is low, the door alarm hom will chirp once every
10 seconds -this means it is time to Install a new battery, Battery life is
approximately t year. Test your door alarm weekly by opening the door
and allowing the alarm to sound.
POOLGUARD is sold with a limited warranty to cover defects in pans
and workmanship for one year from date of purchase. (Retain proof of
purchase). If Poolguard exhibits a defect, please call our Customer
Service department at 1-800-242-7163. Unauthorized returns will not be
accepted. Proper repair is only ensured when the unit is returned to the
manufacturer. Visit our website at www.poolguard.com to fill out your
warranty registration Information.
PEIM INDUSTRIES, INC.
P.O. Box 658
NORTH VERNON, IN 47265
812-346-2648
poolguardo.
PBM INDUSTRIES, INC.
MADE IN THE USA
REV. 02-15
EMM
Elb-&iIIII
-Supervise children at all times.
-Never permit swimming alone. Never leave a child alone, even
to answer the telephone.
-Always remove the entire solar cover from a pool before
swimming.
• Remember that alcohol and water safety do not mix.
•Have your pool area fenced and the gate locked to prevent
unauthorized entry to the pool, and Install a gate alarm.
-Lock and secure all doors In the house which permit easy
access to the pool, and Install a door alarm.
-Have a responsible adult teach swimming and water safety to
your children.
• Maintain clean, clear water In the pool.
• Do not swim during electrical storms.
-Do not permit bottles, glass, or sharp objects to be used
around the pool.
-Ask your pool dealer how you can Improve your pool
safety —they will be glad to assist you.
-Above all: remember that common sense, awareness, and
caution will allow you to enjoy your pool.
Poolparde
0% %
www.pooiguard.com
CONNECTING DOOR ALARMTO SENSOR SWITCHES
READ THE DOOR ALARM MANUAL FOR INSTALLATION ON ONE DOOR FIRST:
THE SENSOR WIRES ARE PERMANENTLY CONNECTED TO THE DOOR
ALARM. CONNECT BOTH SENSOR WIRES COMING FROM THE DOOR ALARM
TO THE SENSOR SWITCH ON THE DOOR FRAME. THEN USE THE SUPPLIED
JUMPER WIRES TO CONNECT TO THE SCREEN DOOR SENSOR SWITCH
(SEE DIAGRAM BELOW). THE TWO SENSORS SHOULD BE HOOKED UP IN
PARELLEL WITH EACH OTHER.
• THE PLASTIC COVERS ON THE SENSOR SWITCHES 8 SENSOR
MAGNET MUST BE REMOVED BEFORE INSTALLATION
• SWITCHES GO ON THE FRAME BY THE DOOR
• MAGNETS GO ON THE DOOR ITSELF -SEE PICTURE IN MANUAL
EQUIPMENT NEEDED
A. ONE DOOR ALARM AND 2 MOUNTING SCREWS
B. ONE SET OF SENSOR SWITCH AND SENSOR MAGNET AND 4 SCREWS
FOR DOOR FRAME 8 DOOR
C. ONE SET OF SENSOR SWITCH AND SENSOR MAGNET, JUMPER WIRES.
AND4SCREWS
-FOR SCREEN DOOR FRAME AND SCREEN DOOR
IF YOU HAVE ANY QUESTIONS CALL US AT 1-800-242-7103
SCREEN DOOR MAIN DOOR
SENSOR floHswrrGl DOORALARM
Pa.19uo1p
WIRES
Figure 5 SENSIN
WIRES
ASSTHRU
SWITCH
rLO
MODEL DAPT-2 SIGNALING
_ MEETS UL 2017 O
SENSOR
SWITLISTED
i�r1
The horn is 85dB at 10 feet
IMPORTANT
READTHOROUGHLY BEFORE USING ALARM
The product has been designed to aid in the detection of unwanted
Intrusions Into unsupervised areas. POOLGUARD DAPT-2 IS A
SAFETY ALARM SYSTEM AND NOT A LIFE SAVING DEVICE. It
should be used in conjunction with the safety equipment currently In use
and should not affect existing safety procedures.
PG DAPT-2 Manual 021115:Layout 1 2/12/15 12:15 PM Page 2
INSTALLING THE 9V BATTERY IFIG. 2)
9V de alkaline battery. Energizer No. S22 or Duracell No. MN1604
A. Remove the assembly screw from the back of the door alarm and
remove the top cover. (See Figure 2)
B. Pull down the battery spring and install the 9v battery (see figure 2).
NOTE: If the battery spring Is not In the correct position under the
battery, the alarm will not go back together.
C. When the 9v battery is installed, the LED will flash once every 10
seconds. When the alarm sounds, the LED will flash once every
second.
D. Reassemble the door alarm with the assembly screw. NOTE: Once
the battery is installed the alarm may sound accidentally until the
sensors are connected properly.
Your Poolguard Door Alarm is designed to be installed within 12" of the
sensor switch for the sensor wire connection. To mount the door alarm
on wall next to door: —
Figure 2
&HAHOERrHO
jHAncmacta
A. Determine the best location. The door alarm must be installed at least
54" above the threshold of the door.
B. With a pencil, mark 2 spots 2 10 apart vertically (up & down) where
the alarm will be mounted. These 2 marks are where the 2 larger
supplied screws will be inserted into the wall to hang the door alarm.
C. Insert the 2larger supplied screws Into the wall on the 2 marks. Leave
about 5/32' (not Including the head of the screw) of the screw from
the wall.
D. Hang the door alarm on the mounted screws and pull downward until
the screws are positioned in the small end of the. hanger holes in the
back of the alarm.
E If you purchased the OPTIONAL Screen Door KA see section 6. (Figure 5)
A. The Door Alarm comes with, one sensor switch and one sensor
magnet; remove the covers from both of these parts by using your
fingernail or small tool to unclip the cover from the bottom side and
sliding it off the sensor.
B. Each sensor has 2 holes for mounting (Note: Do not mount the
sensors on the side of the door that is Hinged). The sensor magnet
usually goes on the door and the sensor switch is usually mounted to
the door frame.
C. Metal framed doors may need a space between the sensors and the
door using a small piece of wood or double sided foam tape.
D. Install the Sensors Vertically (as shown in Figure 1) or Horizontally.
Maximum space between sensors is 1+1/4". IMPORTANT: If you
Install the sensors Horizontally at the top of a SLIDING door, spacing
between the sensors needs to be between 1" and 1+114".
E. Loosen the two terminals on the sensor switch by loosening the
screws then place either wire end coming from the door alarm
between each of the terminals. it doesnT matter which wire goes to
which terminal, Replace Plastic Covers.
Note: If the cover for the sensor switch does not lock into place because
of the sensor wires, remove the knockout from the side of the sensor
switch cover. (See Figure 4)
Ki
The POOLGUARD DOOR ALARM uses two delay modes which allow
the user to exit and enter the door without the alarm sounding. These
two modes are explained below.
A. FIRST DELAY MODE: When the door Is opened the alarm
automatically goes into the first delay mode which gives you 7
seconds after the door is opened to push the pass thru switch. If the
pass thru switch is not pushed within 7 seconds the alarm will sound
With the door open or closed. To silence the alarm close the door
then push the pass thru switch.
B. SECOND DELAY MODE: When the door is opened and the pass thru
switch is pushed within 7 seconds, this puts the door alarm In the
second delay mode which allows you 14 seconds to go through the
door and close it. When the door is closed within 14 seconds, the
alarm will automatically reset. If the door is not closed within 14
seconds, the alarm will sound.
Figure 4 SENSORswlrcH �PL—ASTICIcovt:R
Oocko
o �TERMItUllS
W
r, m
NOTE: If the alarm sounds for approximately 5 minutes and the door is
still open. The alarm horn will start to pulsate, 5 seconds ON and 5
seconds OFF. The alarm will continue to do this until an adult closes
the door and pushes the PASS THRU switch on the door alarm to
silence the alarm. If the alarm sounds for approximately 5 minutes
and the door is closed, the alarm will reset.
poolguarde
'SAFETY BUOY'
ABOVE GROUND POOL ALARM
IN GROUND POOL ALARM
WITH REMOTE RECEIVER
GATE ALARM Poolguard's
Family of Products
Helps Prolct Your Famtyl
www.pooiguard.com
UNDISTURBED OR COMPACTED L6„ _
SOIL TO 95% MODIFIED 400NU SI
PROCTOR
XRk
POOL SECTION
/
6" MIN.
GUNTIE
r
a
L_#3 @12" OC/ BW FORDEPTHTO 5'
#3 @ 6" OCJ BW FOR DEPTH> 5' ANTI ENTRAPMENT
MAINDRAIN _ I
SCALE: 1/8"=11'0"
Z (off --O� 9- Z
REVIEWED FOR -
CODE® COMPLIANCE
ST. LUCIE COUNTY
BOCC
NOTE: COPING EDGE MAY VARY FROM SQUARE (BUFFED OR TUMBLED) F
TO SINGLEB/N TOBOUBLEB/N
DBN BRICK DBN BRICK
4"CONCRETE
TILE—
4" CONC
4" CONCRETE
1kS11)NlYllrvQ
TILETILE1/4%
3/8"
BRITE
CANTI-LEVER
MARBLE
DBNBRICKPAVER D BRICKPAVER
CONCRETE
ON CONCRETE OR MARBLE ON SAND W/ CONCRETE SPRAY DECK
OVER-POURWALL SECTIONS ;
R P.E 416668
1
scREFarFrlCLGsuRE
KOV
SWBB41NG POOL PLAN FOl?�� �pe� --EPiS N�iQ
'�
5f8" OR BETTER PLYWOOD SHEATING
ENGINEERING (BY OTFiERS)
_ _ _ - - \ - bar' �,�♦.
♦°
2"X4"X8"@TOC
FINISHID
- BRICK PAVERS
0
�o. 166E8 s_
RE-STEMREST
yll
U
OFOR
2
OR I #5
- — STP�TE
UOUS CONTINUOUS
0 IN
SHORINN G DETAILFOR
SB N ffi�
SFOOTEkDFTAIL
CREEN EN CLOSURE
2500 PSI CONCRETE W/6"X6" # 10/,10
STEEL WIRE MESH OR FIBER MESH, (llb/YD.)
4" RE OR RE -STEEL
�8
OR 1 #5 RE -STEEL
CONTINUOUS
EL-SID ENGINEERING
#EB-0006831
139, ISLE VERDE WAY
PALM BEACH GARDENDS, FL 33418
FOR:
.4 rnii -, rl
(NO EXCEPTIONS W
FOOTER DETAIL
FOR SCREEN ENCLOSURE
SWIM.INBENCH DETAIL SWIM OUT BECHDETAILNTS DRAWN BY:
DATE:
SHEET 1 OF 3
JOB NO:
Z-1'' �E1Z1RN�
�0 1 LEA gU4P�lE>�S
VALVE
n
ti
FA
� 40
PIPE SCHEMATIC
SCALE NTS
WATER LEVEL
6" MIN-12" MAX
H/W VAC LOCW400
FBC 2017 SEC 4K N59.1.6.5.3.2
& ANSI/ASMB A112.19.8M
It
Co.1;P�M �,f� 3 `'_ 14—tt ( .EPT T.wj - - S .E "- ``-o�
PIPING DIAGRAM
SCALE r iS
POOL
PIPE SIZE FLOW (ft/sec)
FLOW THRU CMP MD GRATES
PIPE FLOW MAIN DRAIN 21
PRESSURE GAUGE & AIR �+ g
SKRANIER 2 a 3.(o
��o g
� WASH RET RETURN TO POOLISPA v �. \ IO
\ AINED ON SITE
FILTER W/
PLEASE VALVE
I PLN2WIRAIRa
�J LLINT STRAII,IER
2#3
TO PUMP
SKIMMER & .VAC DETAIL
SCALE
32" qgANNEL DRAIN
!
ASSUMPTION: POOL FLOW 67% MD 33% SKIIvIIvIER SPA FLOW 100% MD
POOL RETURN 2' FROM PUMP Z� FROM TEE, 1- 1/2" AT INLET
32 CgANNELDRAIN
OPENAREA= 38.79 IN'
FLOW RATE VERIFIED MAY 2011 TO CPSC TEST PROTOCOL
]APMO LISTED FLOW RATES -
O FOR 2.5" PLUMBING USING TWO OUTER PORTS=308GPM (FLOOR) & 212 GPM (WALL)
O FOR 2.5" PLUMBING USING CENTER PORT ONLY = 200 GPM (FLOOR) & 168 GPM (WALL)
O FOR 2" PLUMBING USING TWO OUTER PORTS = 268 GPM (FLOOR) & 192 GPM (WALL)
6 FOR 2" PLUMBING USING CENTER PORT ONLY =1sa GPM (F1-OO�R) &M A �
DETAIL
12"
L
3-TREAD LADDER
N.T.S.
:K ANCHORS
FUND WIRE
HANDRAIL &STEPS
(240-SQ. IN. MIDI.)
N:T.S.
BECK
ANCHORS
ROUND
RE
REVIEWED FOR
I I ,p°� �� ��pp ae /A� ww ee
! T � ras®®� �®�YO�f���'11VC
cp � R ( ST® LU'VIE COUNT'
sA-
p��q
.•: -• i e�, . ram+®6�C
4^ CONCRETE SLAB OR PAVERS 1- 3/4" X 3/8" TAPCONS OR EQUAL.
POOL EQUIFMENI SECURED
POOL EQUIPMENT/ANCHOR DETAII
NT:
EL -SD ENGINEERING$'���p�;��E
#EB_0006831 0 � • �,� •,, i
139 ISLE VERDE VJ � JUL
PALMBEACIi G NIA°S FN®34�9fi88
s 10 : STATE OF �
i.�. k/�
(WALL)
AIN IN
DRAWN'BY:
SHEET 2 OF 3
70B NO.
NOTES: ONE OF THE FOLLOWING POOL
SAFETY FEATURE OPTIONS MUST BE PROVIDED SPEC` i; CATIONS:
I. THE POOL MUST BE ISOLATED FROM ACCES,SaiTO A HOME BY
AN ENCLOSURE THAT MEETS THE POOL: BARRIER
REQUIREMENTS OF 454.2.17 OF THE FLORIDA BUILDING CODE`�26
2. THE POOL MUST BE EQUIPPED WITH AN APPROVED SAFETY
POOL COVER.
3. ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM
THE HOME TO THE POOL MUST BE EQUIPPED -WITH AN EXIT
ALARM THAT HAS A MINImum SOUND PRESSURE RATING OF
85DB AT 10 FEET.
4. ALL DOORS PROVIDING DIRECT ACCESS FROM THE HOME TO
THE POOL MUST BE EQUIPPED WITH A SELF -CLOSING,
SELF -LATCHING DEVICE WITH A RELEASE MECHANISM PLACED
NO LOWER THAN 54 INCHES ABOVE THE FLOOR,
*APSP-15 �gq
MINIMUM FLOW FOR 6 HOUR TURN OVER I ` GPM ® !«D_ OD RPM
MINIMUM FILTER AREAS
® CARTRIDGE ��- FT=< lco
❑ SAND r-r=<
❑ DE FT=<
FILTER PUMP Afoul Fto V.a 'js F! P (G5 _T
145 l-'
ELECTRIC RISER DIAGRAM
HOUSE PANEL
200
POOL PANEL
LITES 1P20 2P20 PUMP
0 2/0 1 2P60 IPOOL AUTOMATION AIR BLOWER
ITFPL
ELECTRIC
TO POOL PANEL
HEATER
1" PVC
CL2
2#.4
1P15 GAS HEATER
1#f�1
1 ##9)3RD
ELECTRICAL DIAGRAM.
60 AMP POOL PANEL MANUEL MOTOR STARER SWITCH
W/2#4 & AKCU WITHIN �I {9 HP PUMRMdTOR W/BUJLT-IN
P MIN. ELECTRICAL CONDUIT.
OVERI;OAD SWITCH W/- 2#4 & 198
CU WITHIN 1" MIN. CONDUIT
#8 SOLID CU GROUND
WIRE TO EXISTING PANEL
GFCIPROTECTED)
TIME CLOCK
WP DISCONNECT
S.P.S.T. TOGGLE SWITCH _ _
POOL LIGHTS-� L-12 VOLT TRANSFORMER
(GFI NOT REQUIRED)
JUNCTION BOX_j
1. ALL ELECTRICAL TO COMPLY WITH 20 r NATIONAL ELECTRIC CODE.
ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION.
2. 3-# 12 THHN CU WITHIN 1" MIN. CONDUIT FOR POOL LIGHT(S).
3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. W/#8 SOLID BARE COPPER.
4. PROVIDE W.P.G.F.I.OUTLET 10' MIN. - 20' MAX FROM WATERS EDGE.
S. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B}201-1;.
I T�EENGINEERING.PLANS COMPLY WITH rth EDITION FBC 201�. SEC R 4501FSEC 454.1/ R101.2.1 PRIVATE
Sw[h t,flNG POOLS. ENGINEERING DESIGN, CONSTRUCTION AND WOKAN
ANSUAPSP -I5,7. ANSUNSPI ,M
.ASPC/ICC-4,5,6. p PI49? & NSP-5.
2. GUNTTE TO ATTAIN 4000 PSI @ 28 DAYS.
3. RE -STEEL TO BE IATE GRADE 40 ASTM 615 STANDARDS, PLACED TO ACI STANN'DARDS.
4. PIPING & PLUM,M IG $E SCH. 40 & 80 PVC PIPE TO CONFORM TO NSF STANDARDS & FBC 454.2.3,2.13.2
PURPLE PRIMER APPLIED PRIOR TO ALL GLUE JOINTS FBC PLUMBING SEC. 6.05.21 WATER PLUMBING
PRESSURE 35 PSI FOR 15 MRRTFES (No AIR PRESSURE) SEC. 454.2.12.1.
5. ALL RE -STEEL, LITES, LADDERS & HANDRAILS BONDED W / #8 GROUND WIRE TO NEC. # 680 / 2011-
6, SOIL STATEMENT: SWIMMIIIG POOUSPA/PATIO - BEARING PRESSURE 2500 PSF. IvIINIIv1UM.
7, POOL/SPA SURROUNDED BY SCREEN ENCLOSURE OR 4' FENCE WITH SELF -CLOSING GATES. HOUSE SAFETY
BARRIER TO BE " BABY" FENCE OR ALARM SYSTEM PER CODE. FBC Z02A
8. POOL/SPA HEATER INSTALLATION ION TO FBC. 2.14.1 HEATER TO HAVE THERMOSTAT AND HIGH PRESSURE
CONTROL TO LIMIT WATER TEMPERATURE TO <104°F. FBC. SEC. 454.2.14.4.
9. ALL GAS PIPING . ; FUEL GAS SEC. 24.2.25 / ALL ELECTRICAL TO NEC. #680 / 201-1.
10. AFTER COMPLETION, THE POOL/SPA MUST NEVER BE DRAINED BY THE HOME OWNER FOR ANY REASON
WHAT -SO -EVER. A LICENSED POOL CONTRACTOR MUST BE CONSULTED TO ACCOMPLISH THIS.
HYDRO -STATIC RELIEF VALVE IS USED AT ENGINEER'S DISCRETION ONLY. BACK FLOW PREVEtiIER ON
WATER SERVICE (WPB ONLY)
11.THE POOUSPA EQUIPMENT SHALL BE SECURED TO A SUBSTANTIAL PAD SO AS TO EL 1MNI ATE STRAIN ON
• PIPING.
12. TYPE'O' POOL WALLS VERTICAL WITHIN 110, DRAINAGE POOL/PATIO TO GRASS (PBC)
13. EL-SID ENGINEERING ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS. OR
REQUIRED SETBACK AREAS. THE POOL CONTRACTOR SHALL VERIFY ALL LAYOUT DIMENSIONS IN FIELD
WITH HOUSE AND LOT LINES PRIOR TO CONSTRUCTION; ADDITIONALLY, UNDER AND OVER GROUND
UTILITIES AT SITE. WATER EDGE SHALL BE 10' MIN. (HORIZONTAL) FROM OVER HEAD ELECTRIC LI1h1ES.
14. THIS ENGINEERING PLAN REMAINS THIS SOLE PROPERTY OF EL-SID ENGINEERING AND IS
NON-TRANSFERRABLE.TO ANYONE WITHOUT EXPRESS PERMISSION OF THIS ENGINEER
15. WAR$ANTY: THIS ENGINEER WARRANTS THE SERVICES PERFORMED BY EL-SID ENGINEERING ARE
CONDUCTED IN A MANNER CONSISTENT WITH THAT LEVEL OF CARE AND SKILL ORDINARILY EXERCISED BY
MEMBERS OF THISFROFESSION CURRENTLY PRACTICING UNDER SIMILAR CONDITIONS. NO OTHER
W� EXPRESSED OR IMPLIED ARE MADE.
16. ANGLE OF REPO;; 6UTERIA (ST. LUCIE COUNTY) FOR POOL LESS THAN 5' FROM HOUSE:
(1) #3 RE -STEEL Q0/BW- (2) GUNTTE THICKNESS 6" MINIMUM.
POOL DATA & EQUIPMENT & CRITERIA:
POOL DIMENSIONS 1 "' AREA PERIMETER + V
DEPTH VARIATION VOLUME `5 31 W GALLONS
SPA DIMENSIONS �- RAISED W/ JACUZZI JET S
�QoyS LITES
POOL/SPA PUMP Tl ' [� ` /� HI-T� _T- LS 200
PUMP •IO5 HP �� GPM f� \o�i 1 v� TURNOVER RATE iD2S
LITES POOL HEATER BFTTtL
HANDRAIL 1 t SWIM�9&-IN �
DIAMOND BRITEIGEM COAT S' �"TN'/ K O COLOR
SLIDE DIVING BOARD AUTO - VAC CLEA`iER INLINE CL2 2nU D"f
SHEER DESCENT WATER FALL 4 0. 3(04 -LIONSHEAD/ROSETTE 2- LED WeLms
Vtwo11111m,'
PB 20D8
Ql INSTALL IN SKIMMER:
• USING PROPER SIZED PLASTIC BUSHINGS, POOL BOND CAN BE INSTALLED
IN ONE OF THE THREADAD SKIMMER OUTLET PARTS. SEE `ASSEMBLY PROCEDURE'
FOR PROPER LIGHTENING OF POOL BOND.
2QINSTALL IN A RETURN LINE:
• POOL BOND CAN BE INSTALLED IN THE FILTRATION RETURN LINE ADJACENT TO INLET FITTING
AVOID INSTALLATIONS THAT COULD TRAP AIR.
• IF ACCESS IS REQUIRED FOR SERVICE PURPOSES, A SPRINKLER SYSTEM
VALVE BOX CAN BE USED FOR ACCESS.
DO NOT INSTALL AS SHOWN TRAPPED AIR WILL
PREVENT PROPER CONTACT WITH WATER
QINSTALL ON SUCTION SIDE ADJACENT TO EQUIPMENT PAD: p FILTER
INSTALL ON SUCTION SIDE PLUMBING AT LEAST 3" BELOW WATER LEVEL-
IF ACCESS IS REQUIRED FOR SERVICE PURPOSES, A SPRINKLER
SYSTEM VALVRBOX CAN BE -USED.
WIRE RECEPTOR TAB —� POOL BOND CASTING
98 SOLID COPPER \\
BONDING WIRE
SPLIT BOLT
1" MALE PIPE THREAD
E MI -POTENTIAL BONDING GRID
NEC 680.26 (C) 201.1:
ALTERNATIVE METHOD PER
FL. SENATE BILL SR 2836
EXECUTIVE ORDER 2007-197
SIGNED JUNE 19, 2007
FBC 101.2.1
SINGLE 98 AWG BARE SOLID COPPER WIRE
AROUND ENTIRE PERIMETER OF POOL AND
CONNECTED TO POOL RE -STEEL IN 4-EQUALLY
SPACED PLACES FROM #8 SOLID INSULATED
TAILS AND CONNECTED W/APPROVED
MECHANICAL FASTENERS i.e., SPLIT BOLT,
BRONZE PIPE CLAMP (W/BRONZESCREWS).
"I Mri-POTENTIALBONDING
48 SOLID GROUND WIRE SHALL BE POSITIONED
4" TO 6" INTO SUBGRADE MATERIAL ADJACENT
TO POOL STRUCTURE. THIS #8 WIRE SHALL BE
BONDED TO POOL STRUCTURE REBAR IN 4
EQUALLY SPACED POINTS. THIS #8 WIRE SHALL
BE PLACED 18" TO 24" IN PROXIMITY TO POOL
i Q-TOTT(-TTM AT. WALL.
LED LIGHT -
LED LIGHT DETAIL
CONCRETE
PAD.
RECOMENDED 3" BELOW
WATER LEVEL
PIPE REDUCED TO 1'
�AND RUN TODECK BOX
2" SCH 40 PVC
SLEEVE
SP 10-22 WALL
FITTING OR EQUAL
INSTALLED INSIDE PIPE
WATERL V
4"-6"
18"-24"
GRADE FOR PAVER
OR CONCRETE DECK
NTS
MATT RTAi r A-V eQ.S W/DOD bI CL\) / EO
SCREEN ENCLOSURE{ n� �-�j FENCE { fir
ALARMIBARRIER lJM\1 r F JCE: Ar PODL. ILRPM'Ne—M - 5f
AUTOMATION
JUL \s�a2r
oEL-SID ENGINEERING
IEB-0006831 ;
139 ISLE VERDE WAY v No. 16668
PALM BEACH GARDENDS FL 33418ir
_� a
STATE OF °40Z
G a N
REVIEWED FO911ii 1 a0�\°
CODE COMPLIANCE
S` . LUCIE COUNTY
®OCc
DATE:
SHEET 3 OF 3
JOB NO: