Loading...
HomeMy WebLinkAboutDrawing1 D=0.27' 20" R=390.00' L=3.10'� U MI 1 � If a U N � a J II O 3 f O � Q) 3 - ac N It z 0 �---- 30.Cr 07•------ � 0-0-FIRC �I W t 5 co cV � O OIO zI o Jam! a7 _O W = i 'j 1111N, ,;ae i E.AC;( N.0 UNIT 7 (OCCUPIED) �f o o r ELECTRIC TRANSFORMER' ! i S81'36'25"E 131-20' FIRC (0.76-W)_ 4 1 —v FIR O s} .ri � vi ; �ti ; �►' � 00 - v ------ t f f 64.4' 13 ------ Nye t I1 o FIRO z6.s' U N o r f UNIT 6 _�--2p'�-- ; o c� coNc W - ONE-STORY ^i a j _ (�v RESIDENCE co - 22.2' co fh 2.5' __ �- � - - CONCRETE ( ) CRIVEY/AY N Tp GAS @ p --- --------- 36.4' 23. 4- 4C.8• -- Plc a P N S82'27'38"E 120.66' FIRC (c.s W) (Basis of Bearings) UNIT 5 I (OCCUPIED) WILLIAM B. BENNETT Professional Surveyor do Mapper Florida Certificate No. 6353 LB No. 7608 LEGEND �$ = SANITARY MANHOLE §1 = SANITARY CLEANOUT CL = CENTERLINE RIGHT OF WAY CONC = CONCRETE FP = FDGE OF PAVEMENT F£ = TELEPHONE RISER FIRC = FOUND 5/8" IRON ROD = WATER METER & CAP (UNNUMBERED) A/C = AIR CONDITIONER PAD FIR = FOUND 5/8' IP.ON ROD GEN = GENERATOR PAD (UNNUMBERED) WF = WOOD FENCE: D = DELTA ANGLE DUE = DRAINAGE & UTILITY EASEMENT L = ARC LENTH jr = CABLE TELEVISION RISER R = RADIUS i = PLUS OR MINUS v, Ar 1 Gld hcv sucr.^.4ay Ci,. i aim Cmy.FL,740`N '°� S I TIE 10 a+a. V e7onb�raesne,• Vicinity Map (Not To Scale) LEGAL DESCRIPTION: unit 6. HARBOUR RIDGE —PLAT 8—SWEETBAY VILLAGE. according to the mop or plat thereof, as recorded in Plat Book 26. at Page 6 ("A" through "E"). of the Public Records of St_ Lucie County, Florida. LOT AREA: 11.706 Sq. Ft.; 0.27 Acrest STREET ADDRESS: 1614 NW Sweelboy Circle, Port St. Lucie, Florida 34990, SURVEYORS' NOTES: 1. Bearings shown hereon are based cn the South line of subject property as platted and bears S 82'27'38" E. 2. Written dimensions take precedence over scaled dimensions and distances are not to be scaled for construction and/or design purposes. 3- Ali distonces and bearings are as held measured and are coinc',de•nt -oAln -PLAT" and description data unless otherwise noted. 4. This drawing is not valid without the signature and original raised seal of a Florida licensed Surveyor & Mapper. 5. This survey is based upon o description furnished by the client• there has been no search of the public records done by this office. 6 Property lies in Flood Zone "X" as scaled from the National Flood Insurance Program Rate Map, Community Panel Number 12111CO406 K. with an effective date of February 19. 2020. 7. This survey is not covered by professional liability insurance. S. City water & sewer are available in this area. 9. This survey meets the required accuracy as shown in Ch. 5J-17.051 (2) (b) based on its expected use. 10. No underground utilities or improvements were located unless otherwise shown. r'ERTIFIED TO: RICHARD T. & BARBARA P. CLARKE Date of Lost field work:08/28/2021 Boundary Survey ,.�e n n e tt Prepared on the order of: Bennett Sutve in ichard T. Clarke & Y 9 Inc.. Barbara P. Clarke 107 Augusta Court Field: JP/BB .lob No.: 21-0811 Jupiter. Florida 33458 tel- 772.336.4933 Drawn: WB Date:08/30/2021 email; bennettsurveyingOyahoo.com Scale: 1"=20' 1 Sheaf: 1 of 1 IU o ZLL,m� W W M Z W — W W 5'.. LJ_ W W 07 YZU J' Ucoa z O W z W U L/yLJ o N � 1..1� o UCCJ 05i10 Z ZM�z WQ) _/ Wt WzO(00 Q�� �a0LL z tQ N a lJ i Q Z W Lu W I_- U) LET NUMBER OF5 STRUCTURE CRITERIA DESIGN: w *THIS OVERALL DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 AND 20 OF THE 2020 FLORIDA BUILDING CODE U 7TH EDITION, BUILDING AND ALL OTHER APPLICABLE STANDARDS W }' o O Zm� M WIND CRITERIA: *VELOCITY: 'C', wo w 150 MPH (3 SECOND GUST), EXPOSURE RISK CATEGORY I. W w u- FOR VELOCITY >100 MILES PER HOUR, IMPORTANCE FACTOR SHALL = 0.77. W w co SCREEN DESIGN: V Y z U *18 X 14 SCREEN WALLS: WW PRESSURE @ 19.6 PSF, LW PRESSURE @ 15.6 PSF, ROOF @ 5.4 PSF v j DESIGN PRESSURE ON BUILDING ENVELOPE ELEMENTS: U co *PER THE ALLOWABLE STRESS DESIGN FOUND ON TABLE 2002.4 AND 2002.4A OF THE FLORIDA BUILDING CODE. *THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN IN THE DRAWING. THE ACTUAL SPACING BETWEEN ANY TWO BEAMS MUST BE THE AVERAGE SPACING, +/ 2", AND THE CENTER TO CENTER MUST NEVER BE GREATER THAN 8'-0". zLo U w GLAZED OPENINGS SHALL BE PROTECTED BY PRODUCTS ,- cl-i*EXTERIOR N mU4 8 Z_j 0 W W o WHICH MEET THE REQUIREMENTS OF SSTD 12. d�+ w0OVwZ J 3 W SCREEN ENCLOSURE ROOF TYPE � Ly J a W a g *GABLE ROOF ENCLOSURE WITH 3'0" RISE MAX. STRUCTURE IS CONNECTED TO EXISTING ¢ �' a SINGLE STORY C.B.S. HOME WITH WOOD FASCIA. (SEE CONNECTION DETAIL 4 ON PAGE 3). CONCRETE; *THIS ENCLOSURE WILL BE CONSTRUCTED ON EXISTING 4" MONOLITHICALLY POURED CONCRETE PATIO THIS FOUNDATION IS ACCEPTABLE FOR THIS ENCLOSURE. d z *ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 12" ON CENTER W/2-.1/4" MIN. EMBEDMENT INTO CONCRETE Z W Lu a cm D abz ALUMINUM NOTES: () Z Q w �/ U) wJNd' C7LLP MATERIALS SHALL CONFORM TO THE F.B.C., CHANGES SHALL BE DESIGNATED BY THE ENGINEERcf) . W 0 OF RECORD: O J . a i z Z Q N °- 3 1: ALL EXTRUSIONS: ALUMINUM ALLOY #6005-T5 OR 6061-T6, (NOTE: SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALUMINUM Z w ALLOY 6061-T6, IF THIS ALLOY IS MORE READILY AVAILABLE). Q . 2: FASTENERS:. ALUMINUM ALLOY # 2024-T4 & #7075-T6 DOUBLE CAD -PLATED STEEL, HOT DIPPED GALVANIZED STEEL OR 300-SERIES STAINLESS STEEL 3: MATERIAL UPGRADES (STRONGER OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME. 4: NO EXPANSION BOLT MAY BE INSTALLED WITHIN 2" OF EDGE OF CONCRETE SLAB. z 5: NON STRUCTURAL ALUMINUM SHALL HAVE A MINIMUM THICKNESS NO LESS THAN z 0.032" (KICKPLATES ETC.) < v 6: ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH LU U- ALKALI RESISTANT COATING. w 7: ALUMINUM IN CONTACT WITH WOOD SHALL BE PAINTED WITH TWO COATS OF HEAVY z . BODIED BITUMINOUS PAINT. 8: SELF MATING BEAMS (SMB) UP TO 8" TO BE FASTENED WITH BEAM STITCH SCREWS @ 16" O/C BOTH SIDES. (#12 SMS),.FOR 9" & 10" SELF MATING BEAMS (SMB) TO BE FASTENED WITH BEAM STITCH SCREWS @ 12" O/C. , SHEET NUMBER 1 OF 5 1 PLAN VIEW SCREEN ROOF I ELEVATION A. 2 SIDE WALL ELEVATION B. 3 FRONT WALL , B=BEAM P=POST/PURLIN CR=CHAIR RAIL DJ=DOOR JAMB K/B=KAY-BRACE W/B=WIND BRACE a oc MEMBER SCHEDULE MARK SIZE MAT. THICKNESS DESIGN W. F. B1 2"X 8" ALUM. 0.072 0.224 PER ENG. B2 2"X 9" ALUM. 0.082 0.306 PER ENG. P1 6"X 6" ALUM. 0.25 0.25 PER ENG. P2 211X 3" ALUM. 0.050 0.050 PER ENG. P3 2"X 7" ALUM. 0.055 0.120 1 PER ENG. P4 1"X 2" ALUM. 0.046 0.046 1 PER ENG. CR I 2"X 3" ALUM. 0.050 0.050 PER ENG. DJ 2"X 2" ALUM. 0.046 0.046 PER.ENG. (P5)(W/B) 2"X 2" ALUM. 0.050 0.050 PER.ENG. ELEVATION C. 4 SIDE WALL >EE PAGE 4 FOR CONNETION DETAILS W O J z Ill W U �rclotQl CU W c,) LU J=N C) W LL 1 0:Lu 6Jz Lu 3:W23:w D lJJ J a=m�ag a O w Z U z W �� ce Wow, � ;gg Z am U z Z;oW ,� �LL�� f� J v o0 O Q °' Naau. Z J Z w Q z 0 z u a ¢ w w SHEET NUMBER 2OF5 SLPICE PLATE ALLOY: MITER SPLICES SHOWN FOR MANSARD SPLICES, IDENTICAL 6061T6 OR 5052H32 SPECIFICATIONS FOR GABLE AND/OR STRAIGHT BEAM SPLICES 0 O 0 00 0 0 00 INTERNAL SPLICE 11j2IOZ �p9 SCREW POSITIONS NEAR MITE OF PSCREW POSITIONS NEAR MITER JOINT MAY BE ADJUSTED �ENGtN TO ACCOMODATE PURLIN, SPACE BETWEEN FASTENERS ALONG MITER JOINT MAY 1 1/2" TO 2", MANTAIN MAXIMUM AND MINIMUM DISTANCES BETWEEN SCEWS. EDGE DISTANCE FOR SCREWS: 314" MINIMUM SCREW SPACING: 5/8" SPLICE SPECIFICATIONS PER TABLE 109 BELOW TYPICAL ELEVATION FOR BEAM MITER SPLICE 'I (DETAIL MAY BE ROTATED FOR GABLE RIDGE SPLICE, AND MAY ALSO SERVE AS SPECIFICATIONS FOR A STRAIGHT SPLICE, MANTAIN PLATE AND CONNECTOR SPECIFICATIONS IN TABLE 109 FOR ALL) BEAM SLPICE DETAILS TABLE 109 BEAM SPLICE PLATE DIMENTIONS #14 SMS PER SIDE PER END I TOTAL #14 SMS PER SPLICE FASTENER SPACES THICKNES 3LENGTH HEIGTH NUMBER OF SPACES HORIZONTAL VERTICAL 2X6X0.050X0.120 SM 3/16" 16" 5 1/4" 14 56 3 3 2X7XO.055X0.120 SM 3/16" 16" 61/4" 14 56 3 3 2X8X0.072XO.224 SM 3/16" 18" 7 1/4" 1 16 64 1 4 2X9X0.082X0.306 SM 3/16 18" 81/4" 18 72 4 4 10X0.092X0.389 SM 114" 20" 1 9" 1 22 88 1 4 1 6 IF DESIRED THE 3/8" BOLT SHOWN IN THE WIND BRACING CONNECTION THAT SECURES THE 2 X 2 X 0.90 MEMBER -TO THE U-BRACKET. AND THE U- BRACKET TO THE ROOF BEAM CAN BE REPLACED WITH FOUR (4) $14 SMS. THE #14 SMS. MUST BE 1/2" FROM THE END OF THE U-BRACKET AND AT LEAST 314 APART (STAGGERED) FROM EACH OTHER. PURLI NG m (U-BRACKET CHANNEL 1/4" THROUGH i INSIDE VIEW WITH 4 # 14 SMS BOLT INTO BEAM OR PERLIN) U-BRACKET i (CHANNEL) a ALTERNATE CONNECTION # 14 SMS TWO OF CHANNEL BEAM OR PERLIN H#14 ON EACH SIDE SMST . SMS THRU OF BRACE SEON THRU BEEAM B CTI \` (U BRACKET CHANNEL) WEBINTO BACKING PLATE ROOF BEAM =0r IJUL F I PURLIN OR EAVE RAIL 3 SCREEN ROOF DIAGONAL WIND BRACE "Z" GUTTER INSERT IN SUPER GUTTER TO HOUSE CONNECTION 10" LONG (0.125 THICK) EXTRUDED'T' BAR GUTTER INSERT, TYP. CENTERED ON EACH ROOF BEAM, WITH (4) FOUR # 14 TEKS THRU TOP LIP OF GUTTER 5"STRUCTURAL GUTTER (CONT.) 4-1/4"X 21M' LAGS IN EACH 10" INCH INSERT AND AT 24" O.C. (MAX. SPACING) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/5/32" BIT TO AVOID SPLITTING) 1X2 SCREEN FRAME "T'GUTTER INSERT rV SUPER G 2"XW X 0.125" (CUT 2" LONG) WITH 3-INCH LEG GUTTER AGAINST 1X2 CLIP, SHALL HAVE FOUR (4) # 14 GUTTER ELEVATION INTO SIDE OF ROOF BEAM AND TWO (2) #14 X 2" LONG TEKS (PER ANGLE CLIP) TRHU TYP. 2X? SCREEN OF BEAM GUTTER AND INTO GUTTER INSERT(TYP. ONE (MAY BE FLAT OR SLOPED) ANGLE CLIP ON EACH SIDE OF EACH BEAM 4 TOP VIEW PLAN I v O ZM0) O W I-- M ow W _i co > LLLL W mac~ YZ— U�(L V le •— (jW MLLJp�j c, z--jia;rn M-Wwc. =o d+ 09�UJZ WU� OWo W J W JWJH?D: a, 6 cC a LI J 0 2 CL O ~ Z ULLI W Z WN Q ❑cm uj ;�a ❑rnooZ L.I. U z zvow v� Chu �0 W 0) fn z 0 0 Z_i r- 3: Z N a LL W Z 0 U) UQ WW zo z 0 U SHEET NUMBER 30F5 2"X3"X 3116" BY 2" LONG ANGLE EACH SIDE 3 EACH #14 S.M.S. EACH SIDE(3/4" O.C. MIN. 3/8" DIA CONCRETE ANCHOR W/2" EMBEDMENT (MIN.) 2" MI 2" X T' SMB COLUMN (SHOWN) (COLUMN SIZED PER TABLE) 2"X3" X 3/16" BY 3" LONG (MIN.) EACH SIDE 4 EACH #14 S.M.S EACH SIDE 1/4" TOP CON W/2 1/2" EMBEDMENT L_INTO CONCRETE COLUMN/FOUNDATION FOR LOAD CONDITION 3 .� LOAD CONDITION 3 - CONNECTION UPLIFT CAPACITY = 2,400# CONNECTION SHEAR. CAPACITY = 2,400# 4- # 10 S.M.S. FROM INSIDE FACE OF 2" X 2"/ 2" X 3" OR POST INTO SCREW SPLINES OF 3" X 2" HOLLOW HORIZONTAL HOLLOW (GIRT). GIRT (1" EMBEDMENT MINIMUM.) -.% III I SELF MATING POST OR HOLLOW POST. PARTIAL ELEVATIONS/GIRT TO POST CONNECTIONS 2 W/ CONCEALED FASTENERS 2" x 3" PURLIN MAY BE SLOPING OR HORIZONTAL si OVERLAP BEAM WITH 2- #12 S.M.S ON EACH SIDE COLUMN (PER TABLE) 2 EACH #10 S.M.S X 4" LONG THRU EAVE RAIL 2X2 INTO SLOPING PURLIN SCREW SPLINES END WALL PERLIN CONNECTION DETAIL 6 4 N ALUM -POST 1'4" X 1'-4" X Z 0" IN DEPTH CONCRETE FOOTER • #5 BAR @ 12' #5 BAR X IVLONG EACH WAY TRHU POST ISOLATED FOOTING DETAIL 012 X 3/4' SMS @24' O/C. TOP & BOTTOM DBL;ALUM.BEAM #14 )W4' SMS @24' O/C. TOP AND BOTTOM STAGGERED 2- 30 THROUGH BOLTS WIVY WASHERS. Lzl- ALUM.Posr BEAM ROOF BEAM ROOF BEAM 2"X 3" PERLIN WITH 1 #14 INTO BEAM @ 16" 0 PERLIN PERLIN —\ 0 0 2" X 3" ANGLE 0 0 ON EACH SIDE 0 0 2" X 3" ANGLE OF BEAM WITH 011 EACH SIDE 3414 S.M.S. O BEAM WITH INTO EACH FRONT VIEW 3414 S.M.S. BEAM. INTO EACH BEAM. SIDE VIEW 5 BEAM ATTACHMENT TO FRONT WALL 2" X 3" PURLIN (MAXIMUM PURLIN SPACING T-0" ) SCREEN ROOF BEAMS - SIZE PER TABLE / MAXIMUM SPACING 8' - 0" O.C. BEAM STITCH SCREW @ 24" O.C. TOP AND BOTTOM (#12 SMS TYPICAL) 4 EACH #10 X 2" LONG S.M.S. (TYPICAL) INTO SCREW BOSSES. O ROOF/SECTION OF CONCEALED FASTENER CONNECTION ,'} - ',. :! , ' - .� .. � _ _ ... .. r.._ _ -. .. r _ .. _ _,_.._ �`. ., .�- ' - ,, _.. .. � -- -.. .. .. __ _... . _.. .. _ - i ' , � ' � i. ,� � ., Y .. . . ' .. ' 1 A .` 1 �