HomeMy WebLinkAboutFECFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Meth&4,,,,) 2 2021 ProjectName: BOWMAN ADDITION BuilderName: Street: 6505 FORT WALTON RD. Permit Office: ST. LUCIE COUNTY Permitting p=partm City, State, Zip: FT. PIERCE, FL, PermitNumber: St. Lucie 4cunb, Owner: DUANE & ALLISON BOWMAN Jurisdiction: 6611000 DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 10. WallTypes(1152.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Frame -Wood, Exterior R=11.0 1152.00ft' b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms (Bedrms In Addition) 3(1) d. N/A R= ft2 11. Ceiling Types (1175.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1175.00 ft 6. Conditioned floor area above grade (ft') 1175 b. N/A R= ft2 Conditioned floor area belowgrade (ft2) 0 c. N/A R= ft2 7. Windows(138.5 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: EXISTING R ft2 6 35 a. U-Factor: Sgl, U=0.79 81.00 ft2 SHGC: SHGC=0.50 b. U-Factor: Sgl, U=0.30 48.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 23.0 SEER:14.00 c. U-Factor: Sgl, U=0.29 9.60 ft2 SHGC: SHGC=0.24 Area Weighted Average Overhang Depth: 2.000 ft. 14.Heatingsystems kBtu/Efficiency Area Weighted Average SHGC: 0.389 a. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hotwatersystems -Replacement equipment SHGC(AVG): N/A a. Electric Cap:40 gallons 9. Floor Types (1175.0 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 1175.00ft' b. Conservation features b. N/A R= ftZ None c. N/A R= ft2 16. Credits CF, Pstat Glass/Floor Area: 0.118 Total Proposed Modified Loads: 34.41 PASS Total Baseline Loads: 34.64 I hereby certify that the plans and specifications covered by Review of the plans and'C7g this calculation are in compliance with the Florida Energy specifications covered by this N' ' Code. calculation indicates compliance '� with the Florida Energy Code. rrr/f�'��n •`;Jr PREPAR D 34�*W04JI020 DATE:'2'�02 Before construction is completed,A this building will be inspected�;,f�o compliance with Section ,s 'T I hereby certify that this building, as designed, is in compliance Florida Statutes.�9 with the Florida Energy Code. p.y OWNER/AGENT: BUILDIQFC AL: DATE: DATE: ..�i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 2/23/2021 10:40 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Softw Qj a 4 FORM R4ns_gngn INPUT SUMMARY CHECKLIST REPORT PROJECT Title: BOWMAN ADDITION Bedrooms: 3 Address Type: Street Address Building Type: User Condit!onedArea: 1175 Lot# OwnerName: DUANE & ALLISON BOWMA Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 6505 FORT WALTON R Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: 6611000 Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Detached FL, New/Existing: Addition Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp v DesignLocation TMY Site 97.5 % 2.5 % Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1175 9400 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 EXISTING 875 7000 No 0 2 1 Yes Yes Yes 2 NEW MASTER 180 1440 No 2 1 1 Yes Yes Yes 3 WIC 25 200 No 0 1 No Yes Yes 4 LAUNDRY 35 280 No 0 1 Yes Yes Yes 5 NEW BATH 60 480 No 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation EXISTING 95 ft 0 875 ft2 ____ 0 1 0 2 Slab -On -Grade Edgelnsulation NEW MASTER 27 ft 0 180 ft2 ____ 0 1 0 3Slab-On-Grade Edge Insulation WIC 1 ft 0 25ft2 __-- 0 1 0 4Slab-On-Grade Edge Insulation LAUNDRY 7ft 0 35ft2 ____ 0 1 0 5 Slab -On -Grade Edge Insulation NEW BATH 15 ft 0 60 ft2 ____ 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Compositionshingles 1239 ft2 0 ft2 Light N 0.5 No 0.7 No 20 18.43 ATTIC RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Unvented 0 1175 ft2 N N 2/23/2021 10:40 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FnRIUI'R4nr,_gngn INPUT SUMMARY CHECKLIST REPORT CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Unvented) EXISTING 0 Blown 875ft' 0.1 Wood 2 UnderAttic(Unvented) NEW MASTER 0 Blown 180ft' 0.1 Wood 3 UnderAttic(Unvented) WIC 0 Blown 25ft' 0.1 Wood 4 UnderAttic(Unvented) LAUNDRY 0 Blown 35fF 0.1 Wood 5 UnderAttic(Unvented) NEW BATH 0 Blown 60ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below To Wall Type1 Space N Exterior Frame -Wood EXISTING 11 35 0 8 0 280.0ft' 0 0.25 0.5 0 2 S Exterior Frame -Wood EXISTING 11 35 0 8 0 280.0ft' 0 0.25 0.5 0 3 W Exterior Frame -Wood EXISTING 11 25 0 8 0 200.0ft' 0 0.25 0.5 0 4 E Exterior Frame -Wood NEW MASTE 11 15 0 8 0 120.0ft' 0 0.25 0.5 0 5 S Exterior Frame -Wood NEW MASTE 11 12 0 8 0 96.0ft' 0 0.25 0.5 0 6 N Exterior Frame -Wood LAUNDRY 11 7 0 8 0 56.0f? 0 0.25 0.5 0 7 N Exterior Frame -Wood NEW BATH 11 5 0 8 0 40.0ft' 0 0.25 0.5 0 8 E Exterior Frame -Wood NEW BATH 11 10 0 8 0 80.0ft' 0 0.25 0.5 0 DOORS # Omt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated EXISTING None .32 3 6 8 20ft' 2 S Insulated NEW MASTE None .32 2 8 6 8 17.8 ft' WINDOWS Orientation shown istheentered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 N 1 Metal Single(Clear) Yes 0.79 0.5 N 9.0 ft' 2 ft 0 in 1 ft 4 in None None 2 N 1 Metal Low-ESingle Yes 0.29 0.24 N 4.8 ft' 2 ft 0 in 1 ft 4 in None None 3 S 2 Metal Single(Clear) Yes 0.79 0.5 N 48.0 ft' 2 ft 0 in 1 ft 4 in None None 4 S 2 Metal Low-ESingle Yes 0.3 0.23 N 24.0 ft' 2 ft 0 in 1 ft 4 in None None 5 W 3 Metal Single(Clear) Yes 0.79 0.5 N 24.0 ft' 2 ft 0 in 1 ft 4 in None None 6 S 5 Metal Low-ESingle Yes 0.3 0.23 N 24.0 ft' 2 ft 0 in 1 ft 4 in None None 7 N 7 Metal Low-ESingle Yes 0.29 0.24 N 4.8 ft' 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 783.3 42.98 80.68 .0902 5 2/23/2021 10:40 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM'R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 ElectricStrip Heat/None (Basel None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/None (Baseline as Split Single SEER:14 23 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # CompanyName System Model# CollectorModel# Area Volume FEF None None ftZ DUCTS -- Supply -- - -- Return --- Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 35 ftZ Attic 5 ftZ Defaultl-eakage EXISTING (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingJan Feb Mar HeatinJan �C)j Feb Mar Apr Apr May Jun Jul I May Jun Jul Auge AuSep Oct Nov Oct Nov Ox Dec Dec H Ventin Jan [[ 11 Feb X Mar A r may Jun Jul Aug Se Oct Nov Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8lbs/sq.ft. 0 ftZ 0 ft 0.3 EXISTING Default(8lbs/sq.ft. ft2 ft 0.3 NEW MASTER Default(8lbs/sq.ft. ftZ ft 0.3 WIC Default(8lbs/sq.ft. ftZ ft 0.3 LAUNDRY Default 8lbs/s .ft. ftZ ft 0.3 NEW BATH 2/23/2021 10:40 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA RECEIVED MAR 2 2 2021 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Permitting D.-partment St. Lucia Ccu-,it,! a Project Name: BOWMAN ADDITION Builder Name: Street: 6505 FORT WALTON RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: x Owner: DUANE & ALLISON BOWMAN Jurisdiction: 6611000 w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope ' Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extiend behind pipong and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids nkler cover plates and walls or ceilinos. o.,.,.„ , uiapu lull W, wy waub auan uc in au;uivance wiih me provisions or iCC-400. 2/23/2021 10:41 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 RECEIVED The lower the EnergyPerformance Index, the more efficient the home. MAR 2 2 1011 Permitting C-apartment 6505 FORT WALTON RD., FT. PIERCE, FL, St. Lucie -Ou,7t•/ 1. New construction or existing Addition 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Frame - Wood, Exterior R=11.0 1152.00 ft' b. N/A R= ft 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3(1) d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1175.00 ft2 6. Conditioned floor area (ft2) 1175 b. N/A R= ft2 c. N/A R= ft2 7. Windows- Description Area 12. Ducts, location & insulation level R ft a. U-Factor. Sgl, U=0.79 81.00 ft2 a. Sup: Attic, Ret: Attic, AH: EXISTING 6 35 SHGC: SHGC=0.50 b. U-Factor: Sgl, U=0.30 48.00 ft2 SHGC: SHGC=0.23 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.29 9.50 ft2 a. Central Unit 23.0 SEER:14.00 SHGC: SHGC=0.24 d. U-Factor. N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.389 8. Skylights Description Area 15. Hot water systems - Replacement equipment Cap: 40 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.95 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1175.00 ft2 Credits (Performance method) CF, Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/23/2021 10:40 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1