HomeMy WebLinkAboutAPPROVED Gonzalez 151 Nettles Melry 10-14-21 AllSheetsN 12
- SLOPE
6 ao
O.H.F=7
O
I
5/8" thick light textured
O stucco on typical concrete
block construction
I
I
N
I \/
•
FRONT ELEV/470N
12
-4 1 SLOPE
SCALE: 1/4" = 1'-0"
Extreme Metals 26 ga Metal Roofing installed
per product approval- FLU 11022.5 over Polgglass self adhered
roofing underlagment over 19/32" CDX plywood attached
to trusses per sheeting attachment diagram on roof plan
5/8" thick light textured
tuc r n Qn -tg-picLI -ron.c rat e--
block construction
12
SLOPE -4
5-6,
on
L-- �l Dl-
RE/4R ELEVATION
L-- �l Dl-
RE/4R ELEVATION
Ext
eme Metals
24,
ga Metal
R
ofing i
stalle
per
product
appro
al FL
1-102
2.5 over
P0ILgldS5
s
If adhered
roof
ig and
rlagme
t over
19/32"
CDX
plgwo
d atteched
to
usses
per sheeting
attachment
dia
ram o
roof
plan
5/8" thick light textured
stucco on typical concrete
block construction
F,IGHT ELEVATION
SCALE: 1/4" = 1'-0"
12
,4 1 SLOPE
Extreme
Metals
26
gga Me
al Roc
ing in
alled
per product
approvaF
FLU
11022
3 over
Polgg
ss sel
adher
d
roofinc
under)
gment
over
/32"
CDX
pl9wood
attac
ed
to tr
ses per
sheeting
att
achmet
t diagram
on roof
pl
0
U� - (�) - . (�)
'H.
SCALE: 1/4" = I'-O"
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding
Doors, Windows & Skylights
Opening
Type
NOA FL
NUMBER
Product
Model
#
Manufacturer
Glass
Attachment methodp
Expiration TEST
Date
Maximum
Desi Pressure
g
of Appn roved Tests
1.
FL# 15412.3
Single Hun
g g
1100
Impact
Lawson
5/16"
V4" dia. tapcons w/ min. 1 3/8" penetration to be
spaced per product approval. Contractor shall adhere to
min. edge distances specified in Product approval
+ 80.0 PSF
—
2.
FLU 1542`1.2
Fixed
Glass
6200
Impact
Lawson
�/1�"
1/4" dia. tapcons w/ min. 1 1/4" penetration to be
spaced per product approval. Contractor shall adhere to
min. edge distances specified in Product approval
+ 18.0 PSF
—
3.
FLU 58g1.2
Fiberglass
door
Smooth star
Therma-Tru
1/4" dia. x 3" tapcons w/ min. 1 1/2" penetration
spaced 14" max o.c., 6" from corner p
+ 6�.0 PSF
_
5.
Product
NOA FL
NUMBER
Model #
Manufacturer
Attachment Method
TEST
Expiration
Date
Maximum
Design Pressure
of Approved Tests
Roof
FL# 1�022.5
I.O Nail Strip
26 ga. steel
1�" wide roof panel
Standing Seam
Extreme Metal
Fabricators, LLC
Roofing installed with min. fastener spacing as follows:
Zone 93 — Max spacing = 12" o.c. with 410 x 1 1/2" Hex —Washer
wood screw to penetrate 3/16" min/ thru deck
with Max row spacing = 6" o.c. over peel and stick underlagment
—228 psf corner
Roof
Underlayment
FLU 5259.1
Polgstick TU Plus
Polgglass USA, Inc
Direct bond to deck in compliance with ASTM D41
Siding
STUCCO
ON BLOCK
5/8" Thick light textured stucco on tgplcal
Concrete block construction
STUCCO
ON STUDS
'1/8" thick light textured stucco installed per ASTM C 924 Over ASTM
D type 2 paper backed wire lath nailed to substrate through one layer of
ASTM D Type 2 felt paper using 8d nails. Substrate to be 19/32" CDX
Plywd nailed at 6" o.c. in field and edges with IOd ring shank nails into studs.
Soffit
DENSGLASS
FIREGUARD
Soffit to be two lagers of 5/8" thick densglass fireguard X
finished painted to match body of house
Flood
Vent
FLU 1-1381.1
Flood Vent
Flood Flaps
Per product approval
Rollin
Shutter
FLU 12246.1
Nautilus Rolling
Shutter Sgstem
Expert Shutter
Services Inc.
Provide 1/4" dia. tapcons with min. 1 1/4" embeddment
installed per product approval.
±160.0 PSF
ALL Product
Testing bg: Miami
—Dade Countg Building Code Compliance Office / Product Control Division
I have reviewed
the above and
approved
it by my seal below. ( Architect or Engineer of Record )
FERN IITTING NFORMATION (FORM 100)
2R 2E
Florida Building Code residential: Ith Ed 2020 and ASCE 1-1� for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Speed: 160 mph ultimate
2E 3
Mean Roof Height: 19'-10" Roof Pitch: 2:12 to 4:12 (7 -209
2R
Internal Pressure Coefficient: +0.18
2E
Subjectabilitg to damage from: Weathering: Negligible Termites: Very Heavy_
2R
Width of Roof End Zone: �'-O"
2E 5
Wind Exposure Classification: D
LL
4 LL
Adjustment factor for Exposure Height Using Allowable Stress Design andLILL
LL
Load Combination per ASCE 1-10 Section 2.4 DL+LL; DL+0.6WL, 0.6DL+0.6WL
LL
5LHLL
Exp Height Ad j Factor: 1.55 x Load Factor 0.6 = 0.93 applied below
HIP ROOF
Components ll Cladding Wind Pressure (NET) Roof Zone: I. +32.0/-5-4.0 psf
Roof Zone: 2E/3E +32.0/-12.0 psf
Roof Zone: 2R +32.0/-94.0 psf
Components $ Cladding Wall End Zone Width: 3'-O"
= Roof Zone I
WALL Components It Cladding Wind Pressure: Zone 4: +�{3.0/-��.0 psf
Walls Zone 4
Zone 5: +-43.0/-58.0 psf
Components It Cladding Wind Pressure (NET) on Garage Door:
ED = Roof Zone 2E/2R
Zone 5 = 16'-O" x 1'-0" CAD = +37I.0/--45.0 PSF
walls Zone 5
Zone 5 = 10'-0" x 71'-0" CAD = +39,0/--f9.0 PSF
END ZONE
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? Yes
Are Components an Cladding Details Provided? Yes
es
- _ Roof eZone n3
Minimum Soil Bearing Pressure: 2,500 psi, Presumptive: X By Test: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: IMPACT GLASS: X BOTH: NEITHER:
�
L N
v
1fa
Q U
v
SE
Q�
X 1%
--
ii
r
0)
N
w
o
O
�
U
O
..Z
W
oo�U
O
�o
4
0000 0000
JCZ
0
rr
<
z
NN
#
I
v
cu
�
~
�
��U`,-,gym
O
rr�
-Q
�3
_
W
x
� L v
>L
U4-3
LN
4-3
-tk+
0)
O.H.
n�
V
5/8" thick light textured -Q
stucco on typical concrete (�
block construction O O O L
LEFT ELEVATION
SCALE: 1/4" = 1'-0"
Uigitally signed
by Daniel R.
Braden
Date: 2021.10.14
15:29:49-04'00'
SHEET NO:
OF S.
JOB NUMBER:
21-151
o
c
O�%ELD
�p®0�� .0
00 o
AR 9770
o�
�� ���D °per •�n0�
12'-5"
_ o D
/6/cv O O 5 Shelves _1
0 00 000 0
W
iL
�--------- - - - - -- - T
/ 8' x 18' Parking
0-1
o 5'-0°-1O CARPORT o .0
Roll/up I E)Shy�tter
air
---------------- �r, Nz
H.B� O
2T-8"
4_T 8"
Designed 'per 322.2.2.1
Provide Flood Flaps FLU 11381.1
engineered flood vent - installed per
manufacturers recomendations.
I vent = 220 sq. ft. of coverage
Carport = 242 sq. ft. - 2 vent required
Vents to be 8" above garage floor
Provide L20 lintel above vents
FIRST FLOOR P L /4N
O
Q o 3,_,144
0
TH
40'-0"
i
Open R ling
Open Below
4r
' Pantry
_abine
a-
W
O
u
WINE_ ;
I
I
MICRO;
KiTCHEN
DW
[71E] -
O Ell I I IOE
LIVING
SIC
7'-8„
O
-4" stud w
ry
D
12'-5"
SCALE 1/4" = 1'-0"
Rod Self
r---
I M STER I LQ
C O S T I,
N
HOWER
.LOSURE
#
O
36 Railing 2'-
�' O, r (k
TANK
TER
Li
I -< xi
un
HE TER
9" m
I " 2
L -Q-�J
FRONT
LOAD
_ _
rAH671
O
WASHER
DRYER
m
M
�ljoveJ
3
0
MASTER
O
BEDROOM
m °D �EDl�00M
N
_
42Fl
N
°'
L
IN
Io
Ln
IF y
EGRESS
EGRESS C
n
ra n
n n r:i
n n
r�lnl I I I I Imlr
a I I I I n Ir• i
SECOND FLOOR FL/4N
1 2'-8„
ilo
0 0 0 00
Q � o
0o
ASTER 2.
BATH
�0 0
�o
\rye -10
UJ in dcw Schedul&
Mark
Size
Window Description
I.
3'-1" x 5'-3"
SINGLE HUNG - EGRESS
2.
2'-2" x 5'-3"
FIXED GLASS
3.
2'_2" x 2'_2"
SINGLE HUNG
4.
-2" x 3'-2"
SINGLE HUNG
2'-2" x 5'-3"
SINGLE HUNG
6.
4'-0" x 5'-3"
FIXED GLASS
6'-O" x 5'-3"
FIXED GLASS
g.
I'-4" x 6'-8"
FIXED GLASS
9.
4'-2" x 5'-3"
SINGLE HUNG
10.
4'-0" x 3'-O"
FIXED GLASS
- AIL Windows to be white ESP aluminum windows with tint.
Provide muntin's and structural mullions per elevations. See
product approval chart for window manufacturer information.
- ALL windows to withstand Pressures stated in Permit
information Box on these plans.
- ALL windows in bathrooms to be tempered
- ALL windows within 18" of finished floor to be tempered
unless impact rated.
- verify all masonry/rough opening sizes prior to ordering windows.
D oor S ch�duI&
Mark
Size
Door Description
A
B
3'-O" X 6'-8"
FOAM FILLED FIBERGLASS 4 PANEL
C
6'-O" X 6'-8"
FOAM FILLED FIBERGLASS L PANEL
D
2'-8" X 4'-8"
SOLID CORE- WOOD
E
2'-8" X 6'-8"
SOLID CORE -WOOD - POCKET
F
G
4'-O" X 6'-8"
SOLID CORE -WOOD - BIFOLD
H
J
1'-0" X L'-8"
SOLID CORE- WOOD
- ALL exterior doors including garage doors to withstand
pressures stated in permit information box on these plans.
- verify all masonry/rough opening sizes prior to ordering
windows.
2�_Seeproduct approval chart on these plans for exterior
door manufacturer information (including garage door)
Provide one exit door (swing type) that is 3'-0" wide
minimum and one emergency escape door (not shuttered).
If escape door has glazing then it must be impact resistant
and shall NOT be thru garage. This may be the same door
if it meets both criteria listed above.
First Floor Square Footage
First Floor A/C , 85 sq. ft.
Carport = 210 sq. ft.
First Floor Total = 955 sq. ft.
Second Floor Square Footage
Second Floor A/C = 102� sq. ft.
Second Floor Total = 102� sq. ft.
Under Roof Square Footage Breakdown
First Floor Total = 955 sq. ft.
Second Floor Total = 102,o sq. ft.
Total Space Under Roof = 1981 Sq. ft.
A/C Space Breakdown
First Floor A/C = 184 sq. ft.
Second Floor A/C = 102� sa. ft.
Total A/C space = 1810 Sq. ft.
Total Cubic volume = I4480 cu. ft.
SCALE 1/4" = 1'-0"
I.
Contractor to verify ALL notes and dimensions prior to
proceeding with work.
17. All exposed attic insulation materials Installed on attic
floors shall have a critical radiant
2.
Contractor to STRICTLY enforce ALL OSHA requirements.
flux not less than 0.12 watt per square centimeter.
Exposed foam plastic Insulatlon
3.
ALL Lumber to be used as Beam, rafters, etc... to have
materials exposed on the underside of the roof deck
or on the attic walls shall comply
a minimum 1,400 P.S.I. fiber stress.
with F.B.C. Resldentlal Section R314 - see permit
info box of code edition
4.
No diSSimilar metals to touch.
18. G psum board material shall conform to ASTM C3�,
C79, C475, C51-4, C�30, C`�31
S.
ALL Concrete used for slabs shall be 2500 PSI concrete, and
C4�0, C1002, C1041,C1111, Ci118, C1218, C1395,
or C139� and shall be Installed
ALL Concrete used for vertical filled cells, continuous. tle beams etc.. to
according to the following:
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
�. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws.
1. ALL wood In contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
mil. ALL plumbing fixtures to be low flow.
10. Contractor to Provide a 2'-8" wide door at one bathroom for
handlcap accessibility requirements.
11. Lowest finished floor to be set by Governing Building Department
surveyor to set in field.
12. Separation between residence and garage shall be per FBC R309.1 and R309.2
13. Door between garage and residence shall be 1-3/8" solid wood - 20 min. fire rated
14. Insulatlon Including facings such as retarders or Vapor permeable members Installed
within floor -Calling assemblies, roof -celling assemblies, wall, crawl spaces and attics
shall have a flame spread Index not to exceed 25 with an accompanylng smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Dr wall
Thickness
Location
Orientation
Framing
Member
Max. spacing
of fasteners
Mail sizing options for
installation of drywall into
Spacing
Nails
Screws
Maximum
wood framing members
2" x min. thickness
Ceiling
Perpendicular
24"
T
12"
13ga 1 3/8" long with 19/64" head
OR
0.098" diameter x 1 1/4" long
/2
annular -ringed or 5d cooler nail
OR
Walls
Either
W,
8„
161,0.080"
dia. xx 1 5/8" long with
Direction
15/64 head
OR
Gypsum board nail 0.086" dia.
with 9/32" head.
x 113ga
Ceiling
Perpendicular
24"
-11,5/8"
12"
1 5/8" long with 19/64" head
OR
0.098" diameter x 1 3/8" long
s
annular -ringed or 6d cooler nail
Walls
Either
161,
g"
W,
0.092" dia. xR 1 -1/8" long with
Direction
1/4 head
OR
Gypsum board nail 0.0915" dia.
x 11/8" with 19/64" head.
Insulation shall comply with F.B.C. R31�.
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 19. ALL ceramic tile surfaces Installed shall conform to ASTM A108.1 thru A108.�,
1i�. gall and celling finishes shall have a smoke -developed Index of not greater than 450 A108.1, A118.1, A118.3, A13�.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers In accordance with ASTM
C1288, C1325, OR CIli8 and installed I.A.W. manufacturers recommendations shall
metal I top plate
5/8" drywall ceiling on
truss bottom cord
Filled Cell Masonry Column With One
45 From Footing To Beam.
Conc. FIII To Be 3000 PSI
See Floor Plan For Location
_tj Li
" �{
drywall on 2S1ngle Filled Cell Column
2" x ' metal studs at W' o.c.
Finish to match existing Qj
NTS
Filled Cell Masonry Column With One Q►
45 From Footing To Beam Each.
metal bot track
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
cn
4" concrete slab with fibermesh OR
E
Typical baseboard 6"x6" 410/10 WWM on 6 mil Visqueen
clean compacted termite treated fill
over
(L
O
QL
interior Non -Bearing Partition
N \
o
\
\
Scale: 1/2" = 1'-0"
N \
0
Double Filled Cell Column
NTS
I I
IV
V
CA
Q
1-19
I I I I E
+_3 r
C)
-C
i Dowel (1) 45 bar I' m
w/ 25" min lap
a and C embed II
II II L--
II Fin. II ---
Floor
Epoxy Cont. Concrete Footing 3O" min"
( AtB ) MIX
l 1 iss&d T i& ED own F &baIr
nts Corner Steel La
3� High
2" dia. handrail
attached to Wall W/
nts
min. 1 1/2" between o
l..L
Provide two ply
floor joist for stairs
17 risers at LS9 high
1-4 treads at 11 deep
2" x 12" Treads
Q�
_<
!!nn N
nvJ
(2 2" x 12" wood beam W EE o
boted to girder truss with UJ o
0 (2 5/8" dia x 5" lag screws �- Z z N
with min 3" separation betwee LU oo 0) +-) o
screws at each web location < <
LO OD u Q
< 000 U
Hang stringers to beam using
Simpson HGA 10 with (4) �
1/4" x 3" wood screws into beam 0000 ra
and (4) 1/4" x 1 1/2" wood screws i Z N N #
into stingers o v
�() CA
STORAGE
2" x 12" Stringer U Q r r
one on each side of stairs BELOW B CC I O I I I W U m
~ Lq (�
��
Type "X" drywall L nnU,, ~ N
' 3
Attach stringers to floor using �
Simpson HGA 10 with (4)}
1/4" x 2" tapcons into floor
and (4) 1/4" x 1 1/2" wood screws
into stingers
STAiR DETAIL -Q
Attach door to block wall with
1/4" dia. x 3" tap -cons with min.
1 1/2" penetration at 12" o.c. max
and 6" o.c. max from each corner thru
I" x 8" PT Buck
k
2 sides t header
D etaiI at Exterior D oors
NTS
(113
Scale: 1/2 = I -0
fnAttach window to block wall with
1/4" dia. x 3" tap -cons with min.
1 1/2" penetration at 12" O.C. max SHEET NO:
and 6" O.C. max from each corner thru
Exterior face I" x 4" PT Buck
of wall
r JOB NUMBER:
I"x4" P.T. Buck 2 H S 1
2 sides t header �ODoo
Detail at I.Jindows oo�
nF IF
NTS
Digitally signed
by Daniel R.
Braden
Date: 2021.10.14
15:29:39-04'00'
oVoOC L . AD4 O
��0000Da��
SECOND FLOOR R Mfg
TYPICAL NOTES: Scab: 1/4" = 1'-0"
- ALL Plywood sub -flooring to be saturated w/ Thompson's
water seal Immediately after installation for leak protection.
- Truss shop drawings to be provided by manufacturer
- Any changes to this plan shall be submitted to the
architect for approval in writing prior to starting construction.
- ALL TRUSS TO TRUSS CONNECTiONS BY TRUSS NANU1=ACTURER
- Architect to review Truss Shop Drawings Prior
to construction for layout and uplift verification
Provide fire stop blocking at all floor trusses dividing the floor
area into SOO sq, f t. (Max.) spaces
ROOF FL 4N
TYPICAL`'f����>OTES� -�
- Overhangs shall be except zero lot line side which
shall be O unless otherwise noted on this sheet
- Roof pitch shall be 4:12 unless otherwise noted on this sheet
- Truss shop drawings to be provided by manufacturer
- Any changes to this plan shall be submitted to the
architect for approval in writing prior to starting construction.
- ALL TRUSS TO TRUSS CONNECTiONS BY
TRUSS NANU1=,ACTURER
- Architect to review Truss Shop Drawings Prior
to construction for layout and uplift verification
- Contractor to provide for Porm Board Survey and to provide
Porm Board Survey to Truss Company prior to truss construction
- Contractor to provide the Architect with truss shop drawings including
ALL truss cut sheets showing ALL truss reactions prior to START
OF: FOUNDATION WORK for strapp and footin�gg size verification.
— TRUSS DEFLECTION SHALL NOT EXCEED 0.5 ON ANY TRUSS.
#9 diamond plate
SEE TYPICAL
WALL SECTIONS
x 114" aluminum angles
(4) 1/2" stainless
steel bolts
ELEVATION
#9 diamorn
A/C Compressor Bracket Detail
5/8" drywall
ceiling /
(2) 2" x 6" top plate
3
A/C Compressor Bracket Plan view
SCALE 1/2" = I'—o"
Slmpso5C-WI E 2102'ht=e0el0truss
truss with (24) IOd x 1 1/2" nails
in each strap
Strap studs to plate using Simpson
SP6 strap with (6) 10d x I I/2"
nails in each strap
O
w
LO
-1
Q
x 6" Blocking
_U
O
W
Strap studs to plate using Simpson
SP6 strap with (6) IOd x I I/2"
nails in each strap
ua
u,
co
2" x 6" p.t. bottom plate with
I/2" anchor bolt at 32" o.c. and
Q
min. 7" embedment with 2" washer
0
ua
Tgpical baseboard
4" concrete slab with fibermesh OR
16"x6"
410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
footing see foundation plan
for size and steel req.
Tunical interior B�arinc Partition
See typical section
for wall finish notes
SE,4M
SCHEDULE
Mark
Size and Description
B1
Two
rows of
beam block filled with concrete and (1) #5 bar
continuous
in
each row. Provide precast lintel
filled with
concrete and
(1) U5 bar per lintel schedule continuous
over
openings.
B2
(2)
2" x 12"
SYP #2 Wood Beam
B3
8" x
12" concrete
tie beam with (4) U5 bars
cont.
over
clear spans, provide #3 ties at 8" o.c.
max, spacing
LEDGER SCHEDULE
Mark Size and Description
LGI (2) 2" x 8" PT ledger bolted to wall with (2) 5/8" dia.
expansion anchors at 24" o.c. staggered with min.
, embedment into wall
(2) 2" x 8" PT ledgger bolted to wall with (2) 1/4" x
LC 2 5 114" tapcons at 12" o.c. max staggered.
II
Typical Flooring on 3/4" CDX plywood sub —flooring Q I
screwed and glued to floor trusses. ALL plywood -
sub —flooring to be saturated with Thompson s Q r
water seal immediately after installation for leak protection
base board Provide Simpson H2.5 strap
at each floor joist to ledger connection
W' deep Top Chord Bearing
floor trusses at 24 o.c. typical
R-30 batts insulation
5/8" Drywall
Ledger LGI
see ledger schedule I Bea beam schedule
Floor Truss to Block L1Jall ,4ttachment Detail
Scale: 1/2" = 1'-0"
HiP ROOF SHEETiNG
ATTACHMENT DETAIL
I. Minimum
Nail Size
= 8d angular ring shank (min.
2.5" long)
2. Minimum
Screw Size = 48 x 2.5"
3. Minimum
Sheathing
Thickness 19/32" CDX PI
wood
4. Use nails or screws based on pressure for roof stated
in permit
info box
on these plans for appropraite
roof
zones.
O
4 FT (LE
3
F
�
FA%
Q� k%
2
2E
I
2
4 FT
2R
FT R
2E
2
ink
F F,N
��
�
Q
O
4 FT 2E 4 FT
Ke
Area
Edge
Field
Fastener
Pressure
Zone
I
8d
x
2.5"
ring
shank
45
psf
Zone
2E, 2R
8d
x
2.5"
ring
shank
psf
Zone
3
4"
4"
8d
x
2.5"
ring
shank
1 8.4
psf
An
Zone
�"
�"
#8
x
2.5"
Screw
263
psf
Contractor to brace all top and bottom chords in floor
and roof trusses in the following manner:
- install first row of truss bracing 36" from exterior walls
and spaces 12" o.c. thereafter top and bottom chords
- install bracing on any top or bottom chord which is longer
than 12" in clear span.
All truss bracing to be 2" x 4" wood and shall be attached to
top of bottom chord and on bottom of top chord of trusses.
usses spaced per truss
nufactures plans
apical splice
ttach bracing to truss chord
ing (2) IOd nails in all
cations
" x 4" wood bracing
I" x 6" PT Fi
4" prefabricata
aluminum gutter
Zero Lot Line Oy&rhang
Scale : I" = I'—O"
Additional
`
45 bars
Lintel
Bar
Clear
"A"
It It
Length
Length
Span
Bars
Bars
CLEAR
r h COVER
2'-10"
2'-8"
I'-6"
2,#3
none
i • i Precast Lintel
3'-4"
2'-2"
2,93
none
SF8-OB/IT
Additional
4'-O"
3'-10"
2'-8"
2,93
none
- bars
CLEAR :'Z
COVER One Row of Beam
4'-6"
4'-4"
3'-2"
2,43
none
5'-4"
5'-2"
4'-O"
2,43
none
Block Above
2,44
none
N ry Precast Lintel r M
6'-6"
6'-4"
5'-4"
2,#4
none
i .., , i
Additional i i
7'-
2"
2,45
none
COVER--- y tt5 bars----'
8FI6-IB/IT 8FI6-IB/2T
$'-4
10"
7'-O"
2,#5
none
NOTES:
ALL reinforcing steel is grade 60.
I. MIN. COVERAGE OF STEEL - 1.5"
2. MIN. BEARING REQUIRED $ EA. END = 4"
3. STANDARD FOR REINF. STEEL = ASTM A615 GRADE LO
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LiNTEL SCHEDULE
Window
Pre-
Rows of
Max.
Max.
Max.
Mark
ounDoo
Lintel
Cast -Crete
Stressed
k
BM Block
Bottom
Top
Load't4
Lolad
Lateral
Width
Size
Specification
Steel
Size
Steel
Size
(PLF)
(PLF)
(PLF)
L20
2'-0"
2'-10"
8F8-0B/IT
NO
—
1
#5
3069
1569
1642
2'-2"
L31
2'-6"
3'-9"
BPS-OB/IT
NO
—
I
#5
2561
1363
-763
2'-8"
3'-1"
L45
4'-5"
5'-I"
8F8-0B/IT
NO
—
I
#5
1349
1016
411
L50
5'-O"
5'-8"
8F8-0B/IT
NO
—
I
tt5
1105
909
339
L60
6'-8"
6'-8"
8F8-OB/IT
NO
—
1
#5
1011
727
534
L10
T-0"
T-0"
8F8-0B/IT
NO
—
I
#5
1011
l2l
534
L80
8'-0"
8'-8"
8F8-0B/IT
NO
—
I
tt5
699
591
512
L90
9'-0"
9'-8"
8F8-0B/IT
NO
—
I
#5
535
530
401
1_I00
10'-O"
IO-8"
8F8-0B/IT
NO
—
1
45
582
414
452
- ALL LINTELS
SHALL
BE MADE BY CAST-CRETE.
- LINTELS
SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD
REQ.
REQUIREMENTS
- LINTELS
OVER
13'-II" LONG ARE TO BE PRESTRESSED.
- CONTRACTOR
TO VERIFY ALL LINTEL SIZES BASED ON FINAL
MASONRY
OPENING
SIZES AND ADJUST LINTELS ACCORDINGLY PRIOR TO ORDERING
ANY/ALL
LINTELS
STRAPPiNG SCHEDULE
HETA 20
HETA 20
SIMPSON HETA 20 hurricane
anchor at each truss supporting
Max. 1,810 lbs. uplift. Strap shall
have (9) lOd x 1 1/2" nails.
nts
Digitally signed by
Daniel R. Braden
acZ2— Date: 2021.10.14
15:29:27-04'00'
LL
V
Q
N
0
S-1
0
v
U
-0
U
N
W
LU
o
O
�
O
ZLLI
oo
O
( U
00�
r
<
z
N N
$t
i
�WU���m
a-
W
�
( Q)
U_
L
mN
U
�
SHEET NO:
3.
OF S.
JOB NUMBER:
21-151
Conni
Saud
2" VTR
JL
'I
I
I
2"
< I
i
i IN,
SANITARY RISER
nts
Sanitar�
L&g&n�
Sanitary line
Bath Tub "P" trap
BT--
— — —
Vent Line
Shower "P" trap
SH�
Li v-'
Lavatory Trap
wM-'
Washing Machine Drain
F'
Sink Trap
F'
Urinal
we-i
Water Closet
r�-'
Water Fountain Drain
FI
Floor Drain
E
Grinder Pump
T
Clean Out
i 2" VTR
2" Vent thru Roof
2" vTw
J
1
2" Vent thru
wall
2"
Pipe Diameter Designation (2" dia)
NOTES:
— ALL sanitary pipe
to be Schedule
-40 PVC
— Slope hall be no less
than
1/8" per foot
and no more than 1/4" per foot
6" min. of Icynene LD—C-50 spray foam insulation on
Extreme Metals 26 ga Metal Roofing installed bottom of roof sheathing in compliance with IOC—ESR—I�bar vert. w/
per product approval- FLU 11022.5 over Polyglass self adhered dated Feb. I, 2018. Install DC 315 Intumescent coating3 " overlap
roofing underlayment over 19/32" COX plywood attached per section -4.3.2 of ICC test noted above to comply
to trusses per sheeting attachment diagram on roof plan with 15 min. thermal barrier requirements.
Simpson HETA 20 or equal
hurricane anchor at each truss 12
with (10) IOd x I in nails
( 24" o.c.) supporting Max.
1810lbs. uplift
Prefabricated aluminum gutter
shop drawings by mfg on
Galt' —Alum Tletai drip
on 2" x 6" fascia I I F_
M
Soffit to be two layers of 5/8" thick
densglass fireguard X finished painted t
match body of house
#5 bar vert. w/
30" overlap
5/8" thick light textured
stucco on typical concrete
block construction
Grade
#5 bar vert. w/
30" overlap --
1EFM
PRE-ENGINEERED TRUSSES
at 2-4"o.c. TYPICAL
( shop drawings by manufacturer )
5/8" drywall with smooth finish
BI 1/2" drywall over I" x furring
strips at IC o.c. with R4.2 fyfoil
insulation on typical 8" Block walls
All drywall is per FBC -102.3.1 and
shall meet all pertaining ASTM codes.
Mortar to be Type "1T, only.
Provide Our—O—Rock at alf wet
areas (ex. showers, tubs etc...)
Fill cell with concrete and
(1) 45 bar vert. (typical).
Max. spacing shall not exceed
32" unless otherwise noted
see foundation plan notes for
spacing at openings
Typical flooring over 15/32" CDX plywood screwed to
trusses or joists thru 23/32" CD X plywood sub —floor.
Typical Install 15/32" plywood with 48 x 2.5" wood screws at -4" o.c.
Baseboard max. spacing over 15 lb felt. Install 23/32" COX plywo d
screwed and glued to trusses or foists with #8 x 2' screws
at 12" o.c.
� 16 deep pre —en sneered wood �r
floor trusses at � -4" o.c.
R-30 batts insulation
5/8" Drywall ceiling
See floor truss attachment
detail on framing plan
1/2" drywall over I" x furring
strips at 14" o.c, with R-4.2 fgfoil
insulation on typical 8" Block walls
All drywall is per FBC 102.3.1 and
shall meet all pertaining ASTM codes.
Mortar to be Type "M" only.
Provide Dur—O—Rock at alr wet
areas (ex. showers, tubs etc...)
Beam BI
milli IVA
SEE PILING
PLAN BY OTHERS
1/2" expansion joint
TYPICAL SECTION
Fill cell with concrete and
(1) 45 bar vert. (typical).
Max. spacing shall not exceed
32" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
6"x6" 410/10 wwM on 6 mil Visqueen over
clean compacted termite treated fill
Scale : 1/2" = 1'-0"
Digitally signed by
Ae42Daniel R. Braden
—Date: 2021.10.14
15:29:16-04'00'
Iu
V
Q
L CAQ I (�
Q r Ll
Q
W
W
E
O
UJ
W
Z
00 U
CA CA
<
00O
Q-
I I U
r r
Z
OD OD
z
NN
O
CA
rr�
�
U
—Q
W
U
"�
~
W
�X>Lvi
N
QC
v
'T
A•1�1
U_
M
SHEET NO:
ED - I
OF S.
JOB NUMBER:
21-151
a� c
Dc
R. SRA0I_�'� �o O
o
AR 9777700
0%a
0
—)
V
�I
r
N
N
4