Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c NIA R_ ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11 • Ceiling Types(1336.0 sgft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1306 a. Under Attic (Vented) R=30.0 1306.00 ft2 Conditioned floor area below grade (ft2) 0 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. NIA R_ ft2 7. Windows(128.9 sqft.) Description Area 12. Ducts, location & insulation level R ftz a. U-Factor: 891, U=i .02 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtulhr Efficiency c. U-Factor: Sg1, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) NIA NIA ft2 SHGC(AVG): NIA 9. Floor Types Yp Insulation Area 15. Hot Water Systems a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 fi2 a. ElectricTankless Cap: 1 gallons b. NIA R= ft2 EF:0.600 c. NIA R= ftz b. Conservation features None 16. Credits None Glass/Floor Area: 0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this ' .5r, Code, calculation indicates compliance with the Florida Energy Code. PREPARED BY: . Before construction is completed DATE: �_�-Q2� this building will be inspected for compliance with Section 553.908 Q' Florida Statutes. I hereby certify that this building, as designed, is in compliance - ► with the Florida Energy Code. OT ► OWNERIA T: ^ BUILDING OFFICIAL: DATE: _. DATE: -----r---••-- ,- ••--- ��................+� ..� a. na:w:c: uuu r:lanuiduLurer inat Ale air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNETIICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/7/2021 11:47.00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Addresstype: Street Address Building Type: User Bedrooms: 1 Lot#: --- Owner: WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: -- Total Stories: 1 PlatBook: Builder Name: WYNNE BUILDING CORP. Worst Case: Yes Street THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County. St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE Design Design Temp IntDesignTemp Heating Design Dailytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL, Fort Pierce FL_VERO-BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13UN762001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes 3 SINK AREA 42 3402 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes _10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim PerimeterR-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234 It 0.473 - 0.00 1.00 0.00 -2 Slab -On -Grade Edge Ins DEN 24 0 144 It 0.473 - 0.00 1.00 0.00 _ 3 Slab -On -Grade Edge Ins SINK AREA 7 0 42 It 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 _5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452It 0.473 - 0.00 1.00 0.00 _ 6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50 ft 0.473 - 0.00 1.00 0.00 _7 Slab -On -Grade Edge Ins POWDER - 1 0 25 It 0.473 - 0.00 1.00 0.00 _ 8 Slab -On -Grade Edge Ins KITCHEN 38 0 232 It 0.473 - 0.00 1.00 0.00 _ 9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40 ft 0.473 - 0.00 1.00 0.00 10 Slab -On -Grade Edge Ins STORAGE 21 0 24 ft 0.304 - 0.00 0.00 1.00 677/2021 11;47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch J# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft' 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (I in) Area RBS IRCC 1 Full attic Vented 150 1306 ft' N N CEILING (Total Exposed Area = 1336 sq.ft.) # CeilingType Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type 1 UnderAttic(Vented) MASTER BEDROOM 30.0 Blown 234.Oft' 0.053 0.10 Wood _2 UnderAttic(Vented) DEN 30.0 Blown 144.0ft' 0.053 0.10 Wood _3 UnderAttic(Vented) SINK AREA 30.0 Blown 42.0ft' 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.0ft 0.053 0.10 Wood _5 UnderAftic(Vented) GREAT ROOM 30.0 Blown 452.0ft' 0.053 0.10 Wood _6 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.0ft' 0.053 0.10 Wood _7 UnderAttic(Vented) POWDER 30.0 Blown 25.0ft' 0.053 0.10 Wood _8 UnderAttic(Vented) KITCHEN 30.0 Blown 232.0ft' 0.053 0.10 Wood _9 UnderAftic(Vented) LAUNDRY 30.0 Blown 40.0ft' 0.053 0.10 Wood _10 UnderAttic(Vented) STORAGE 30.0 Blown 24.011' 0.030 0.11 Wood _ 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.0ft' 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1. / Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below �/ # Omit To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 S=>N Exterior Conc. Blk- Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Conc. Bik-Int Ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Conc. Bik-Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc. Bik -Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _ 5 S=>N Exterior Conc. BIk- Int Ins SINK AREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _6 NaS Exterior Conc. Bik-Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _ 7 W=>E Exterior Conc. Bik - Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% _ 8 S=>N Exterior Conc. BIk - Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Conc. Bik-Int ins KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _ 10 E=>W Exterior Conc. BIk- Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _ 11 S=>N Exterior Conc. BIk - Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _ 12 N=>S Exterior Conc. BIk- Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _ 13 NHS Exterior Conc. Blk- Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 14 N=>S Exterior Conc. Bilk - Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% _ 15 N=>S Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height # Omt Adjacent To Door Type Space Stones U-Value Ft In Ft In Area _1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.011' 6/7/202111:47:00 AM EnergyGauge®USA 7.0.00- FlaRes2020 FBC 7th Edition(2020) Compliant Software Page FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) Wall -Overhang- J# Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.02 1.0 It 5 in 1.0 ft 5 in None None _ 2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 ft 5 in 1.0 ft 5 in None None _ 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.02 1.0 ft 5 in 1.0 ft 5 in None None -4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.Oft2 12.0 It 0 in 1.0 ft 5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.9ft- 1.0 ft 5 in 1.0 ft 5 in None None 6 E�W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft2 1.0 It 5 in 1.0 It 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft2 280 ft2 35 ft 8 ft 11 MASS # Mass Type Area Thickness FurnitureFraction Space _ 1 Default(8 lbs/sq.fL) 0 ft2 0 ft 0.30 MASTER BEDROOM _2 Default(8lbs/sq.ft.) 0 ft2 0 It 0.30 DEN _ 3 Default(8lbs/sq.fL) 0 ft2 0 It 0.30 SINK AREA _4 Default(8lbs/sq.ft.) 0 ft2 0 It 0.30 CLOSET _5 Default(8lbs/sq.ft.) 0 ft2 0 It 0.30 GREAT ROOM 6 Default(8lbs/sq.ft.) 0 ft2 O ft 0.30 MASTER BATH _7 Default(8lbs/sq.ft.) Oft= Oft 0.30 POWDER _8 De%uft(8lbs/sq.ft.) 0ft2 Oft 0.30 KITCHEN _9 Default(8lbs/sq.ft.) 0ft2 Oft 0.30 LAUNDRY 10 Default(8lbs/sq.ft.) 0 ft2 Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity -Geothermal HeatPump- Ducts Block kBtu/hr Entry Power Volt Current _ 1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm _1 Central Unit Splif/Single SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipelength _ 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff _1 No NA NA NA No NA NA NA None DUCTS vDuct —supply— —Retum— Air CFM 25 CFM 25 HVAC # # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0120 fP Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat N Ceiling Fans: N Cooling []Jan [ I Feb [ ] Mar [ 1 Apr [ ] May N Jun [X] Jul [X] Aug [X] Sep [] Oct 1 Nov [ ]Dec Heating [)]Jan Pq Feb N Mar [ ] Apr [ ] May []Jun []Jul []Aug[ ] Aug P ] Sep 11 Oct N Nov [X] Dec Venting []Jan [ ] Feb N Mar [X] Apr [] May [ ] Jun (]Jul [ ] Aug I 1 Sep [X] Oct [X] Nov [ ]Dec Schedule: HERS 2006 Reference Hours VThermostat Schedule Type 1 2 3 4 5 6 7 8 g 10 11 12 _ Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 _ Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _ Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 W712021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA" Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeableinsulationshall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, floor cavity g rig tyinsulation andcantilevered shall be permitted to be in contact with the top side floors) of sheathing, oroontinuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl spacewalls Exposed earth in unvented crawl spaces shall be covered Where provided instead offloorinsulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparabon Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed lightfxtures installed in the building thermal Recessed lightfixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers andtubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or on exterior walls communication boxes or air -sealed boxes shall be installed. HVAC register bcotE HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft') Conditioned floor area below grade (ftZ) 7. Windows"* Description a. U-Factor. Sgl, U=1.02 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.03 SHGC: SHGC=0.27 c. U-Factor: Sgl, U=1.02 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) N/A SHGC(AVG): N/A THE COTTAGE,FT. PIERCE,FL, New (From Plans) Detached 1 1 Yes 1306 0 Area 76.04 fe 40.00 ftZ 12.85 ftZ 4.701 ft 0.281 Area N/A ftZ 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ftZ b. N/A R= ftZ c. N/A R= ftZ 10. Wall Types(1718.3 sqft.) Insulation Area a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ftZ b. Frame - Wood, Adjacent R=11.0 240.00 ftZ c. N/A R= ftZ d. N/A R= ftZ 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ftZ b. Knee Wall (Vented) R=19.0 30.00 ftZ c. N/A R= ftZ 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Ret Attic, AH: Attic 6 120 b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 29.0 SEER:14.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 27.0 HSPF:8.20 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.600 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: �-� Date: Address of New Home: THE COTTAGE City/FL Zip: 5a _cLz Aq 3�Ck *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00- FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsoftg Project Summary Job: Entire House eY QUICK CALCS, INC. 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Pi"W772466-6799 Em il:QUICKCALCS@AOL.COM Proiect Information For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 IF Outside db 90 IF Inside db 70 OF Insidedb 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Duds 4013 Central vent (0 cfm) 0 Btuh Bluh Duds Central vent (0 cfm) 5251 0 Btuh Btuh (gone) e) 0 Btuh Blower 0 Btuh Piping 0 Bluh Equipmentload 20340 Btuh Use manufacturers data n Infiltration Rate/swm multiplier Equipment load 0.95 sensible 19734 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2094 Btuh Ducts 1524 Btuh Central vent (0 cfm) 0 Btuh Heatingg Area Coolingg (none) (flz) 1306 1306 Equipment latent load 3618 Btuh Volume (fP) 10579 10579 Airchanges(hour 0.45 0.23 Equipment Total Load (Sen+Lat) 23352 Btuh Equiv.AVF (cfm) 79 41 Req. total rapacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carder Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3000GOA0 Cond CH14NBO3000GOAD AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heatinginput Sensiblecooling 20300 Btuh Heating output 28000 Btuh @47-F Latentcooling 8700 Btuh Temperature rise 26 IF Total cooling 29000 Btuh Actual airflow, 967 cfm Actual airflow 967 cfm Airflowfactor 0.048 cfm/Btuh Airflowfactor 0.047 cm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 IF Backup: Input=5 kW, Output=18005 Btuh, 100AFUE •. Calculations approved byACCAto meet all requirements of Manual J 8lh Ed. rrVV1r!Rn'✓t60K" 2021-Jan12132e 1 — RigkSufeiJ Uriversa1207919.021 RSW8101 Page 1 ...1WngW6 ftWAC\WVNNEBUIDLING-THECOTTAGE� Calc=NW Frort Doortms:SW wrighWar Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. BY 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phore:772466.6799 Email: QUICKCALCS@AOL.COM 1 Room name Enfire House MASTER BEDROOM 2 E posed wall 145.0 ft 31.0 it 3 Room height 8.1 ft 8.1 it heatbool 4 Room dimerlsons 13.0 x 18.0 ft 5 .Room area 1306.0 V 234.0 fe Ty Con tto5on U-value Or HTM Area Load number (BWhttz°F) (BOAM or perimeter (ft) (Stuh) or perimeter ekr M (BWh) Heat Cool Gras N/P5 Heat Cool Gros N/P/S Heat Cool 6 Y11 13A-4ors 0.143 n 4.00 2.19 446 427 1710 934 0 0 0 0 _G 2glaang.droutr, 1A40 n 29.12 21.68 18 0 537 400 0 0 0 0 y/ 13AAM 0.143 a 4.00 2.19 162 129 516 282 0 0 0 0 2glaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 I�DG 11DO 0.390 a 1092 10.34 20 20 223 211 0 0 0 0 t-G 1344ocs 0.143 s 4.00 2.19 284 277 1107 605 146 146 584 319 2glazing, droutr, 1A40 s 29.12 21.68 7 7 202 150 0 0 0 0 13A4o1s 0.143 w 4.00 2.19 294 192 767 419 105 73 291 159 1A-olom 1270I w 35.56 3477 41 41 1451 1419 0 0 0 0 1A-h1om 1270 w 35.56 61.76 18 3 SW 1139 0 0 0 0 to-htom 1270 w 3556 63.40 33 5 1162 2072 33 5 1162 2072 C 16C-30ml 0.032 - 0.90 128 1306 1306 117C 1672 234 234 210 300 F 22A-gl 0989 27.69 0.00 13M I 145 4015 0 234 31 858 0 6 c)AEDexarson 3591 997 Envelope loss/gain 13885 13393 3105 3847 12 a) Infil9afion 2441 668 522 143 b) Room eenfilabon 0 0 0 0 13 Intemalgains O=pants@ 230 2 460 0 0 Applianoes/other 1000 0 Subtotal (Ilnes6 to 13) 16327 15522 3627 3990 Lessdemal load 0 0 0 0 ta^r Les� 0 0 0 0 Redishibuton 0 0 0 0 141 Subtotal 16327 15522 3627 3990 151 Dudloads 25% 34% 4013 5251 25% 34% 892 1352 Total room load 20340 20773 18 required( ) AirrCm15 967 .7 2 2�2 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. 0\ � wr�~��� 2021-JarF121321:40 f2igk-SuteOUnveMI201919.021 RSU0810' Page 1 -.\Wngt6Dft HVAQWYNNESUIDLING-THECOTTAGE.w CaIc=M18 FrortOoorfaces SW wrigbWoft- Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: T72466-6799 Email OUICKCALCS@gOL.COM 1 Room name DEN SINKAREA 2 Exoosedmill 24.0 It 7.0 It 3 Room height 8.1 ft heaVcool 8.1 ft heaMmol 4 Room dimensions 12.0 x 12.0 ft 6A x 7.0 ft 5 Room area 144.0 IF 42.0 T Ty Construction U-value Or HTM Area (ft?) Load Area Load number (fthm-IF) (EftjW) or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gros NIPS Heat Cool 6 W moo s 0.143 n 4.00 2.19 97 97 389 213 0 0 0 0 �G 2glaarg,drout, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4= 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glazing,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 71I 11D0 0.390I a 10.82 10.34 0 0 0 0 0 0 0 0 u�1 13A4c s 0.143 s 4.00 2.19 0 0 0 0 $7 57 227 124 t-G 2glazing, droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13AAocs 0.143 w 4.00 2.19 97 79 315 172 0 0 0 0 1Aclom 1270I w 35M 34.77 0 0 0 0 0 0 0 0 1A-htom 1270 w 35.56 61.76 18 3 656 1139 0 0 0 0 tXhtom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C30m1 0.032 - 0.90 128 144 144 129 184 42 42 38 54 F 22A-tpl 0.989 - 27.69 0.00 144 I 24 665 0 42 7 194 0 6 c)AED ex arson 574 -3 Envelope losstgain 2154 2283 459 175 12 a) Infiltrafion 404 111 118 32 b) Roomvenfilaton 0 0 0 0 13 Internal gains: O=pants@ 230 0 0 0 0 Appliancslother 0 0 Subtotal (lines 6 to 13) 2558 2394 576 207 Lessex2rnal load 0 0 0 0 Lestansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2558 2394 576 200 15 Dud loads 25% 34% 629 811 25% 34% 142 70 Total room loac 3187 3205 734 78 213 Air required 152 149 34 3 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed AftTI'�' wrs9tiisoR' 2021-Jan-121321:40 RigkTHEOO rAGE.401919.0218 Frort01 Paget _.lWrigh5oft FNACiW`MNE BUIDLING-miE COTTAGE.np Calc=M18 Frort Daorfaoss:SW wrightsoft- Right -A) Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FOR -PIERCE. FL34946 Phore: 712466-6799 Email: OUICKCALCS a@AOL.COM 1 Room name CLOSET GREAT ROOM 2 EVosedvsll 0 ft 32.0 ft 3 Room heighl 8.1 ft heatlmol 8.1 t heal/coo[4 Room dimensons 9.0 x 7.0 ft 1.0 x 452.0 ft 5 Room area 63.0 iF 452.0 1F Ty Cons4ucion U-value Or HTM Area (fl Load Area Load number (Bluhff�-q (BWhAF) or perimeter (ft) (Bhrh) or perimeter (ft) (61uh) Heat Cool Gross NiP/S Heat Cool Gras N/P/S Heat Cool 6 N/ 13A-0as 0.143 n 4.00 2.19 0 0 0 0 178 160 640 350 �—G 2glaang,droutr, 1.040 n 29.12 21.68 0 0 0 0 18 0 537 400 13A4ocs 0.143 a 4.00 2.191 0 0 0 0 0 0 0 0 2 glazing, droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0390 a 1092 10.34 0 0 0 0 0 0 0 0 13A4ors 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 G 2glazing, droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13A4ots 0.143 w 4.00 2.19 0 0 0 0 81 40 161 88 1Actom 1270 w 35M 34.77 0 0 0 0 41 41 1451 1419 lA-hlom 1270 w 35561 61.76 0 0 0 0 0 0 0 0 1A-hlom 1270 w 35.561 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0,901 128 63 63 56 81 452 452 405 579 F 22Xtpl 0.989 - 27.691 0.00 I 63 0 0 0 452 32 886 0 6 c)AEDe rson _t 2069 Envelope losgain 56 80 4080 4903 12 a) Infiltration 0 0 539 148 b) Roomwnlilatcn 0 0 0 0 13 Internal gains: Ommpants@ 230 0 0 2 1 460 Applianosloter 0 0 Subtotal(limai6to13) 56 80 4619 5511 Lesse)danalload 0 0 0 0 Leatranser 0 0 0 0 Redistribulion 0 0 0 0 14 Subtotal 56 4 5511 151 Dudloads 25% 34%1 14 27 25% 34% t135135 1868 Total room load 70 107 5754 7379 Airrequired(dm) 3 5 274 343 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed �h RigrcSuteO Uriversa12019 79.021 RBWBtot 2021-Jarv12 t32140 ...1WriglEORHJACIWVNNE BUIDLING-THE CATiAGE.np Calc=M18 FrorcDoorfaces:SW Page 3 wrightsoW Right-® Worksheet Job: Entire House Date: By.QUICK CALCS, INC. 317 ST.. LUCIE LANE, FORT PIERCE, FL34946 Phore:772-466-6799 Email: QUICKCALCS ,AOL.COM 1 Room name MASTER BATH POWDER 2 Expossdwall 5.0 It 0 ft 3 Room height at ft heaV000l 8.1 ft heaNmol 4 Room Eimervsons 10.0 x 5.0 It 5.0 x 5,0 ft 5 Roomaraa 50.0 IF 25.0 IF Ty Construction U-value Or HTM Area 011) Load Area number (BbjWF) (BluhM ( or perimeter (ft) (Bluh) or perimeter (ft) (BWh) Heat I Cool Gros N/P/S Heat Cool Gros N/P/S Heat Cool 6 Vf/ 13AAo s 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 � G 2glazing, droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4= 0.143 a 4.001 2.19 0 0 0 0 0 0 0 0 2glaang,drout, 1.040 a 29.121 39.42 0 0 0 0 0 0 0 0 11 D 11D0 0390 a 10.92 10.34 0 0 0 0 0 0 0 0 W IMAM 0.143 s 4.001 2.19 41 34 134 73 0 0 0 0 I-G 2glaang,droW, 1A40. s 29.12 21.68 7 7 202 150 0 0 0 0 13AAo s 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 14 lA-clom 1270 w 3556 34.77 0 0 0 0 0 0 0 0 1IA-hlom 1270 w 35.55 61.76 0 0 0 0 0 0 0 0 to-hlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C-3Oml 0.032 - 0.90 128 50 50 45 64 25 25 22 32 F 22A-yl 0989 27.69 0.00 50 5 138 0 25 0 0 0 6 c)AM elurson .4 0 Envelope lodgain 520 284 22 32 12 a) Nitration 84 23 1 0 0 b) Room ventilation 0 0 0 0 13 Intemalgains O-pan5@ 230 0 0 0 0 ApplianoWotrer 0 0 Subtlal(lines(ib I3) 604 307 22 32 Lewerkmal load 0 0 0 0 Leas�'der 0 0 0 0 Redistributon 0 0 0 0 14 Subtotal 604 307 22 32 15 Dud loads 25% 34% 148 104 25% 34% 61 11 Total room icad 752 411 28 42 Air required (dm) 36 19 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed .9 A .... RgFOU 201979.002021-Jan-121321:40 \Wrig�iftHVACWYNNEBUIDLING-7HECOTrAGE.np CaIc=MJB FiroortDoorfaces:SW Page E1 wrightsoft° Right,J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST.. LUCIE LANE, FORTPIERCE, FL34946 Phone: 772466-6799 E.ii:QUICKCALC3@ACL.COM 1 Room name KITCHEN LAUNDRY 2 Emosedwall 38.0 ft 0 It 3 Room height 8.1 ft heaV=l 8.1 ft heaV=l 4 Room dimensions 1.0 x 232.0 ft 4.0 x 10.0 ft 5 Room area 232.0 ft' 40.0 ff Ty ConshurAon U-value Or HTM Area If) Load Area (tt) Load number (BWh/ft' 9 (BWhrR'j or perimeter (ft) (BNh) or perimeter (ft) (Biuh) Heat Cool Gros NVFS Heat Cool Gros NrP/S Heat Cool 6 VN 13AA= 0.143 n 4.00 2.19 138 138 551 301 0 0 0 0 L--f' 2glazing, droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4= 0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 2glaang.droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 ill 11D0 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 vi/ 13A4= 0.143 s 4.00 2.19 41 41 162 89 0 0 0 0 L-a 2glaarg,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 w 13A4ar_s 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Aclom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 to-htom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1A-htom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C30m1 0.032 - 0.90 128 232 232 208 297 40 40 36 51 F 22A-to 0.989 - 27.69 0.00 232 38 1052 0 40 0 0 0 6 o)AMe mon -37 -1 Envelope loss(gain 2951 1570 36 51 12 a) Infiltration 640 175 0 0 b) Roomvenfilation 0 0 0 0 13 Intemalgaim Occupants@ 230 0 0 0 0 Appliancesoother 70pp 0 SUbbt�(IlnesW3) 3591 2745 36 51 Lesseaemahoad 0 0 0 0 Lestrt 0 0 0 0 Redistribuibu0on D 0 0 0 14 Subtotal 3591 2745 36 51 15 Dudloads 25% 34% 883 931 25% 34% 9 17 Total roam load 4474 367645 69 Air required;dm) 273 177 2 2 3 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed 2021-JarN21321:40 AC RigttSuteO Umersal 201919.021 RSU08101 Page 5 ...\Wdgt6oft FNAaWYNNEBUIDLING-THECOTTAGE.np Calc=MJB FrontDoorfaws:SW wrightsoft• Right-M) Worksheet Job: Entire House Dom: QUICK CALCS, INC. By. 317ST. LUCIE LANE, FORTPIERCE, FL34946 Phanal72466-6799 E.!I:QUICKCALCS@AOL.COM 1 Room name STORAGE 2 E>posedwali &0It 3 Room height 8.1 it heaVccol 4 Room dimendons 4.0 x 6.0 R 5 Room area 24,0 IF Ty Construction U-value Or HTM Area (� Load Area Load number (BWh%t`--q (13hiw or perimeter (11) (Bluh) or perimeter Heat Cool Gros WAS Heat Cool Gross N/P/S Heat Cool 6 V_G 13A-0as 0.143 n 4.00 2.19 32 32 130 71 29laang,droutr, 1.040 n 29.12 21.68 0 0 0 0 13A-0as 0.143 a 4.00 2.19 32 32 130 71 2gWang,droutr, 1.040 a 29.12 39.42 0 0 0 0 71 11DO 0.390 a 10.92 10.34 0 0 0 0 11/ 13A-4ocs 0.143 a 4A0 2.19 0 0 0 0 t-G 2glaang,droutr, 1.040 s 29.12 21.68 0 0 0 0 13A4ors 0.143 w 4.00 2.19 0 0 0 0 1Aatom 1270 w 35M 34.77 0 0 0 0 1A-h1om 1270 w 3556 61.76 0 0 0 0 lA-hlom 1270 w 35.56 63.40 0 0 0 0 C 16C30ml 0.032 - 0.90 128 24 24 22 31 F I 22A-1pl 0.989 - 27.69 I 0.00 24 8 222 0 6 c)AlDexaudon 3 Enwboe loss'gain 502 170 12 a) Infiltration 135 37 b) Roomventilalion 0 0 13 Ntemal gains: Omipants@ 230 0 0 Appliancesbter 0 SubtoWl(1ines6b13) 637 207 Lessegamal load 0 0 I Lestransfer 0 0 I Redistribution 0 0 141 Subtotal 637 207 151 Dudioads 25% 29% 157 60 Total room load 794 266 Airreguired(cim) 36 12 Calculations approved bvACCAto meet all requirements of Manual J M Ed. 2021-Jan-121321:40 MgttSLiL&Urry ml20l9l9.021RSU08101 Page ...1WrigttwRHVAQWYNNEBUIDLING-THECOTTAGEap Calc=MM FrortDoorfares:SW -- wrightsoft ® Duct System Summary n. Entire House BF QUICK CALCS, INC. 317 ST. LUCIE LANE, FORTMERCE, FL34946 Phore:772-4666799 Email: QUICKCALCS@AOL.COM Project Information For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Extemal static pressure Pressurelosses Available static pressure Supply/return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 028 in H2O 0.22 in H2O 0.11010.110 in H2O 0.080 in/100ft 967 Cfin 126 Supply Branch Detail Table Cooling 0.50 in H2O 028 in H2O 022 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cfm Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Dud Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CLOSET c 107 3 5 0.080 4.0 OxO MFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 Ox0 MFx 33.5 90.0 st1 GREATROOM C 3689 137 172 0.080 8.0 Ox0 VIFx 14.6 70.0 GREATROOM-A c 3689 137 172 0.080 8.0 0x0 MFx 16.1 70.0 KrrCFEN h 4474 213 171 0.080 7.0 Ox0 MFx 4.5 70.0 LAUNDRY C 68 2 3 0.080 4.0 OXO MFx 5.4 70.0 MASTERBATH h 752 36 19 0.080 4.0 OxO MFx 32.9 90.0 st1 MASTERBEDROOM C 2671 107 124 0.080 7.0 Ox0 MFx 27.9 90.0 st1 MASTERBEDROOM-A c 2671 107 124 0.080 7.0 OxO VIFx 35.9 90.0 st1 POWDER c 42 1 2 0.080 4.0 OxO VIFx 29.2 90.0 st1 SINKAREA h 718 34 13 0.080 4.0 0x0 MFx 30.9 90.0 st1 STORAGE h 794 38 12 1 0.080 4.0 OxO VIFx 11.2 70.0 Supply Trunk Detail Table Name Trunk Type Htg (Cfm) Clg (Cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk Sill PeakA/F 441 437 0.080 561 12.0 0 x 0 VinlFlx wrightsoft® 2021-Jan121321:41 �N•W.+-t� RigNSU"Unwrre 1201919.021 RSU08101 Pagel ...1WngY6oftHVAQWYNNEBUIDLING-THECOTTAGE.n.p Calc=MJ8 Fmrf Dooriacea.SW Return Branch Detail Table Name Grille Htg Size (in) (cm) Clg (cim) TEL (ft) Design FR Veloc (ipm) Diam (in) HxW (in) Stud/Joist Opening (in) Dud Mad Trunk rbl Ox0 967 967 0 0 0 0 Ox 0 MR 41- Wr7ghts ft® 2021- 121321A1 lz- RlgkSuhAUrioarsa1201919.021 RSW8101 Page 2 ...\WngF6oR tNA(.1WVNNE BUIDLING-1HE COTfAGEnp CaIc=AM178 Rort Doorfa�xs:SW