Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 is FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Spec Home Builder Name: PSL Prop Street: Lot 20 Sunset Blvd Permit Office: City, State, Zip: Fort Pierce, FL 34982 Permit Number: Owner: Spec Home Jurisdiction: St. Lucie Design Location: FL, St Lucie Co Intl County: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall types (1580 ft2) Insulation (R) Area (ft2) 2. Single family or multiple family Single -Family a. Frm Wall, 1/2" Gyp Bd Ext, R-11 b: Blk Wall, Stucco Ext, R-4.1 Ext 11.0 191.90 4.1 1387.60 3. Number of units, if multiple family 1 C. N/A 4. Number of bedrooms 3 d. NIA 10. Ceiling types (1602 ft2) Insulation (R) Area (ft2) 5. Is this a worst case? Yes a. Attic, Shngls, R-30 Roof Ins, 1/ 30.0 1601.75 6. Conditioned floor area above grade (ft2) 1601.75 b. N/A Conditioned floor area below grade (ft2) 0 c. N/A R Area (ft2) 7. Windows (179 ft2) Description Area (ft2) 11. Ducts a.Sup: House Attic, Ret: House Attic, AH: House 6.0 318.54 a. U-Factor: Dbl Impact, 0.580 45.21 b. SHGC: 0.24 b. U-Factor: Dbl Impact, 0.650 48.00 12. Cooling systems kBtu/hr Efficiency 28.0 SEER: 15.5 SHGC: 0.21 a.Split air conditioner c. U-Factor: Dbl Impact, 0.620 37.99 b• 13. Heating systems kBtu/hr Efficiency SHGC: 0.22 d. U-Factor: Dbl Impact, 0.650 48.00 a.Electric strip 23.5 AFUE: 100.0 SHGC: 0.24 b' Area Weighted Average Overhang Depth: 6.205 ft Area Weighted Average SHGC: 0.228 14. Hot water systems a.Electric conventional (40 gal) Cap: 40 gal EF: 0.96 8. Floor types (1601.75 ft2) Insulation (R) Area (ft2) b.Conservation features a. On Grade Depth, Tile Fir Fnsh 0.0 1601.75 (None) b. N/A C. N/A 15. Credits None 0.112 Total Proposed Modified Loads: 46.35 PASS Glass/Floor area: Total Baseline Loads: 49.00 I hereby certify that the plans and specifications covered by Review of the plans and specifications 'C�� this calculation are in compliance with the Florida Energy covered by this. calculation Indicates compliance with the Florida Energy "'__ Code. cluz ' Ua&m-'� Cade. Before construction is completed, for PREPARED BY. this building will be inspected compliance with Section 553.908 DATE: 12/29/2020 Florida statutes. f I hereby certify that this building, as designed, is in 1r` compliance with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: x - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). 2020-Dec-29 15:09:13 WrilghtSo't' RightSuite®Universal2021 21.0.02 RSU29066 Right -Energy® Florida2017 Section405.4.1 Compliant Software Paget fff t;jc�r�� Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method ,, Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include: 14 ❑ This Checklist ❑ A FORM 405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a -ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst -case orientation, name and version of the compliance software tool, name of individual completing the compliance report (one page). ❑ An input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level (EPL) Display Card (one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO for the Performance method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table 402.4.1.1 - one page) ❑ A completed Form 2017 Envelope Leakage Test Report (usually one page). Section R402.4 or R402.4.1.2 exceptions may apply. ❑ If FORM R405 duct leakage type indicates anything other than "default leakage", then a completed FORM R405 Duct Leakage Test Report (usually one page). 2020-Dec-29 15:09:13 Wright oft- Right -Suite® Universa1202121.0.02 RSU29066 Right -Energy® Florida2017 Section405.4.1 Compliant Software Pagel y,�,r� ...Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R405-2017 Building Inout Summary Report PROJECT Title: Sppec Home Bedrooms: 3 Address type: Lot#: Street address Building Type: FLAsBuilt Spec Home Bathrooms: 2 Conditioned Area: 1602 Block/Subdivision: Owner: # of Units: 1 Total Stories: 1 Worst Case: Yes Platbook: Street: Lot 20 Sunset Blvd Builder Name: PSL Prop Permit Office: Rotate Angle: 0 No County: City, State, Zip: St. Lucie Fort Pierce, FL 34982 Jurisdiction: St. Lucie Family Type: Single -Family Plans) Cross Ventilation: Whole House Fan: No erin:can/Lake Terrain: w New/Existing: Ne(From Year Construct:Shielding: uburban Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp J Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, St Lucie Co Intl FL -Fort -Pierce 2 41 90 70 75 486 57 Low BLOCKS # Name Area Volume 1 House 1601.75 ft2 13784.20 ft' SPACES # Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 M Hall 26.00 ft2 208.00 ft' No 0 0 0 1 0 1 Yes Yes Yes Yes Yes Yes 2 Laundry 68.25 ft2 3 Master Bath 90.00 ft2 546.00 ft' No 720.00 ft' No 0 0 1 1 Yes Yes Yes Yes Yes Yes 4 WIC 63.25 ft2 5 Master Bed 246.50 ft2 506.00 ft' No 0 2095.25 ft' No 0 0 1 1 1 Yes Yes Yes Yes Yes Yes 6 Pantry 15.00 ft2 7 Kitchen/Nook 274.50 ft 120.00 ft3 No 0 2552.85 ft Yes 2 0 0 1 1 Yes Yes Yes Yes Yes Yes 8 Great Room 377.00 ft2 9 Bed 3 172.50 ft2 3506.10 ft' No 2 1380.00 ft' No 0 0 1 1 Yes Yes Yes Yes Yes Yes 10 Hall 29.75 ft2 11 Lin 7.50 ft2 238.00 ft' No 0 60.00 ft' No 0 0 1 0 1 1 Yes Yes Yes Yes Yes Yes 12 Bath 49.50 ft2 13 Bed 2 182.00 ft2 396.00 ft' No 0 1456.00 ft' No 0 0 1 1 Yes Yes Yes FLOORS (Total Exposed Area = 1602 sq.ft.) # Floor TVpe Space Perimeter R-Value Area U-Factor Tile Wood Carpet 1 On Grade Depth, Tile Fir Fnsh M Hall 4 Laundry 11 ft 0 26.00 ft2 ft 0 68.25 ft2 0.989 0.989 1.0 1.0 0 0 0 0 2 On Grade Depth, Tile Fir Fnsh 3 On Grade Depth, Tile Fir Fnsh Master Bath 22 ft 0 90.00 ft 63.25 ft2 0.989 0.989 1.0 1.0 0 0 0 0 4 On Grade Depth, Tile Fir Fnsh 5 On Grade Depth, Tile Fir Fnsh WIC 17 Master Bed 15 ft 0 ft 0 246.50 ft2 0.989 1.0 1.0 0 0 0 0 6 On Grade Depth, Tile Fir Fnsh 7 On Grade Depth, Tile Fir Fnsh Pantry 0 Kitchen/Nook 24 ft 0 15.00 ft2 ft 0 274.50 ft 0.989 0.989 0.989 1.0 1.0 0 0 0 0 8 On Grade Depth, Tile Fir Fnsh Great Room 29 Bed 3 27 ft 0 377.00 ft2 ft 0 172.50 ft2 0.989 1.0 0 0 9 On Grade Depth, Tile Fir Fnsh 10 On Grade Depth, Tile Fir Fnsh Hall 0 ft 0 29.75 ft2 7.50 ft2 0.989 0.989 1.0 1.0 0 0 0 0 11 On Grade Depth, Tile Fir Fnsh Lin 0 Bath 6 ft 0 ft 0 49.50 ft2 0.989 1.0 0 0 12 On Grade Depth, Tile Fir Fnsh 13 On Grade Depth, Tile Fir Fnsh Bed 2 36 ft 0 182.00 ft2 0.989 1.0 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip RoofAsph 1791 f? 470 ft2 Medium 0.75 No Medium 0.75 No 0.90 0.90 No No 0 27 0 27 2 Hip RoofAsph ATTIC 4, # Type Ventilation Vent Ratio 1 in) Area RBS IRCC 1 Full attic Full attic Vented 150 Vented 150 1601.75ft2 N 420.25 ft2 N N N 2 2020-Dec-29 15:09:13 wright,Oft" Right -Suite® Universal 2021 21.0.02 RSU29066 Right -Energy® Florida2017 Section 405.4.1 Compliant Software Page ��fff h1j,,^A, ' Wnghtsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R4Ub-11L)'I l CEILING (Total Exposed Area = 1602 sq.ft.) 4' # Ceiling Type Space R-Value U-Factor Area Framing Fraction Truss Type 1 Attic, Shngls, R-30 Roof Ins, 1/2" G M Hall 30 0.034 0.034 26.00 ft2 68.25 ft2 0.10 Wood 0.10 Wood 2 3 Attic, Shngls, R-30 Roof Ins, 1/2" G Attic, Shngls, R-30 Roof Ins, 1/2" G Laundry Master Bath 30 30 0.034 90.00 ft 0.10 Wood Wood 4 5 Attic, Shngls, R-30 Roof Ins, 1/2" G Attic, Shngls, R-30 Roof Ins, 1/2" G WIC Master Bed 30 0.034 30 0.034 63.25 ft2 246.50 ft2 0.10 0.10 Woad Wood 6 Attic, Shngls, R-30 Roof Ins, 1/2" G Pantry 30 0.034 0.034 15.00 ft2 274.50 ft 0.10 0.10 Wood 7 Attic, Shngls, R-30 Roof Ins, 1/2" G Kitchen/Nook 30 30 0.034 377.00 ft2 0.10 Wood 8 9 Attic, Shngls, R-30 Roof Ins, 1/2" G Attic, Shngls, R-30 Roof Ins, 1/2" G Great Room Bed 3 30 0.034 129.75 ft2 0.10 Wood 0.10 Wood 10 Attic, Shngls, R-30 Roof Ins, 1/2" G Hall 30 0.034 0.034 29.75 ft2 7.50 ft2 0.10 Wood 11 12 Attic, Shngls, R-30 Roof Ins, 1/2" G Attic, Shngls, R-30 Roof Ins, 1/2" G Lin Bath 30 30 0.034 49.50 ft2 0.10 Wood Wood 13 Attic, Shngls, R-30 Roof Ins, 1/2" G Bed 2 30 0.034 182.00 ft2 0.10 WALLS (Total Exposed Area = 1580 sq.ft.) Adjacent Cavity Width Height Sheathing U Frm. Solar Below 4" # Wall Type Space R-Value Ft In Ft In Area R-Value Factor Frac. Absor. Grade% Ornt To 1 Partition Frm Wall, 1/2" Gy M Hall 11 4 0 8 0 0 32.0 ft2 0 84.0 ft2 0 0.101 0.25 0.75 0 0.101 0.25 0.75 0 2 Partition Frm Wall, 1/2" Gy E Exterior Blk Wall, Stucco Laundry Master Bath 11 10 6 8 0 2 0 8 0 16.0 ft 4 0.109 0.22 0.20 0 0 3 4 S Exterior BIk Wall, Stucco Master Bath 0 12 0 8 0 1 6 8 0 96.0 ft2 4 12.0 ft2 4 0.109 0.22 0.20 0.109 0.22 0.20 0 5 W Exterior Blk Wall, Stucco Partition Frm Wall, 1/2" Gy Master Bath Master Bath 0 11 6 0 8 0 48.0 ft2 0 0.101 0.25 0.75 0 0 6 7 E Exterior Blk Wall, Stucco WIC 0 5 6 8 0 0 44.0 ft2 4 92.0 ft2 4 0.109 0.22 0.20 0.109 0.22 0.20 0 8 9 S Exterior Blk Wall, Stucco E Exterior Blk Wall, Stucco WIC Master Bed 0 11 6 8 0 14 6 8 6 123.3 ft2 4 4 0.109 0.22 0.20 0 0.109 0.22 0.20 0 10 E Exterior Blk Wall, Stucco Kitchen/Nook 0 23 6 9 4 0 26 0 9 4 218.6 . ft2 241.8 ft2 4 0.109 0.22 0.20 0 11 12 W Exterior Blk Wall, Stucco Partition Frm Wall, 1/2" Gy Great Room Great Room 11 3 0 9 4 27.9 ft2 0 0.100.25 0.0 0 13 N Exterior Blk Wall, Stucco Bed 3 0 12 0 8 0 15 0 8 0 96.0 ft 4 120.0 ft2 4 0.1099 0.22 0.2200 0.109 0.22 0.20 0 14 E Exterior Blk Wall, Stucco Bed 3 Bath 0 0 5 6 8 0 44.0 ft2 4 0.109 0.22 0.20 0 15 16 N Exterior Blk Wall, Stucco N Exterior Blk Wall, Stucco Bed 2 0 16 0 8 0 128.0 ft2 4 0.109 0.22 0.20 0 8 0 100.0 ft2 4 0.109 0.22 0.20 0 18 W Exterior Blk Wall, Stucco Bed 2 0 12 6 WINDOWS (Total Exposed Area = 179 sq.ft.) Wall Overhang Interior ,1' # Ornt ID Frame Panes NFRC U-Factor SHGC Impact Area Depth Separation Shade Screening 1 S 4 Metal Low-E Double Yes 0.580 0.24 Yes 0.580 0.24 Yes 4.5ft2 1 ft 0 in 15.6ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 1 ft 0 in Blinds 45' outdoor 2 3 E 9 Metal Low-E Double E 10 Metal Low-E Double Yes Yes 0.650 0.21 Yes 48.Oft2 10 ft 0 in 22.4ft2 6 ft 0 in 1 ft 0 in None None 1 ft 0 in Blinds 45° outdoor 4 5 W 11 Metal Low-E Double W 11 Metal Low-E Double Yes Yes 0.620 0.22 Yes 0.650 0.24 Yes 48.Oft2 9 ft 1 in 1 ft 0 in None None 1 ft 0 in Blinds 45° outdoor 6 E 14 Metal Low-E Double 15 Metal Low-E Double Yes Yes 0.580 0.24 Yes 0.580 0.24 Yes 15.6ft2 1 ft 0 in 9.5ft2 1 ft 0 in 1 ft 0 in Blinds 452 outdoor 7 N GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 0 1 INFILTRATION # Scope Method SLA CFM 50 ELA E LA ACH. ACH 50 1 Wholehouse Sim lifted 0.000384 1608 88.46 166.1 0.53 7.00 HEATING SYSTEM 4, # System Type Rithtvnp Efficienc Ca acit Block Ducts 1 Electric strin AFUE: 100.0 23.5 kBtu/hr 1 s s#1 COOLING SYSTEM 41 # S stem TVpe SubtVpe Efficiency Capacity Air Flow SHR Block Ducts 1 Split air conditioner SEER: 15.5 28.0 kBtu/hr 933 cfm 0.70 1 s s#1 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric conventional 0.96 40 gal 60 gal 120 T None +1 aightSQft16 Right -Suite® Universal 2021 21.0.02 RSU29066 Rig ht-Energy® Florida 2017 Section 405.4.1 Compliant Software_ VVV �V '_I;age' 4 ;�: a�� ., ...Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N DUCTS ________ Supply -------- 4, # Location R-Value Area ---- ---- Return Location --------- Area Leakage Type Air Handler CFM 25 Percent Out Leakage QN RLF HVAC # Heat Cool 1 House Attic 6.0 319 fe House Attic 18 ft2 Default Leakage House (Default) 6.00 1 1 TEMPERATURES Programmable Thermostat: Y Ceiling Fans: Cooling [ X ]Jan X [ X] Feb [ X] Feb [ X] Mar [ X] Mar [ X] Apr [ X] Apr [ X] [ X] May [ X] Jun May [ X] Jun [ X] JUI [ X] Jul [X] Aug [ X] Aug [X] Sep [ X] Sep [ X] Oct [ X] Nov [ X] Oct [ X] Nov [ X] Dec [ X] Dec Heating [ ]Jan Venting [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Thermostat Schedule: Florida Building Code, 6th Edition Hours 7 8 9 10 11 12 Schedule Type 2017 1 2 3 4 5 6 Cooling (WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 Cooling (WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 Heating (WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 Heating (WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 2020-Dec-29 15:09:13 ° 014Tr7Cght55oftO Right-Suite®Universal2021 21.0.02 RSU29066 Right -Energy@ Florida2017 Section405.4.1 Compliant Software Page '�-j ...Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Cale = MJ8 Front Door faces: N FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX = 95 The lower the EnergyPerformance Index, the more efficient the home. 1. New home or addition 2. Single-family or multiple -family 3. Number of units, if multiple -family 4. Number of bedrooms 5. Is this a worst case? (yes/no) 6. Conditioned floor area (ftz) 7. Windows, type and area* a. U-Factor: b. Solar Heat Gain Coefficient (SHGC): c. Area (ft2) 8. Skylights a. U-Factor: b. Solar Heat Gain Coefficient (SHGC): 9. Floor type, insulation level a. Slab -on -grade (R-value): b. Wood, raised (R-value): c. Concrete, raised (R-value) 10 Wall type and insulation: a. Exterior: 1. Wood frame (Insulation R-value): 2. Masonry (Insulation R-value): b. Adjacent: 1. Wood frame (Insulation R-value): 2. Masonry (Insulation R-value): 11. Ceiling type and insulation level a. Under attic (R-value): b. Single assembly (R-value): c. Knee walls/skylight walls (R-value) d. Radiant barrier installed 1. New (From Plans) 12 2. Single -Family 3. 1 5. Yes 6. 1601.75 Db7&npact(Avg), 0.626 7b. 0.23 7c. 179 8a. 8b. 9a. 0.0 9b. 9c. 10al. 10a2. 4 10bl. 11 10b2. 11a. 30.0 11 b. 11 C. 11 d. Ducts, location & insulation level a. Supply ducts: R 6.0 b. Return ducts: R 6.0 c. AHU location: House 13. Cooling systems Capacity 28.0 a. Split system: SEER 15.50 b. Single package: SEER c. Ground/water source: SEER/COP d. Room unit/PTAC: EER e. Other: 14. Heating systems Capacity 23.5 a. Split system heat pump: HSPF b. Single package heat pump: HSPF c. Electric resistance: COP 100.00 d. Gas furnace, natural gas: AFUE e. Gas furnace, LPG: AFUE f. Other: 15. Water heating systems a. Electric resistance: EF 0.960 b. Gas fired, natrual gas: EF c. Gas fired, LPG: EF d. Solar system with tank: EF e. Dedicated heat pump with tank: EF f. Heat recovery unit: HeatRec% g. Other: 16. HVAC credits claimed (Performance Method) a. Ceiling fans: b. Cross ventilation: c. Whole house fan: d. Multizone cooling credit: e. Multizone heating credit: f. Programmable thermostat: Yes *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Lot 20 Sunset Blvd Date: City/FL Zip: Fort Pierce, FL 34982 2020-Dec-29 15:09:13 WrlghtSOftO RightSuite®Universal2021 21.0.02 RSU29066 Right -Energy® Florida2017 Section405.4.1 Compliant Software Page Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R405-2017 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Lot 20 Sunset Blvd PERMIT #: Fort Pierce, FL 34982 MANDATORY REQUIREMENTS - See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies reflects components andaspecifi ationsllsubmitted o demo st ategned ompliancethe bforlder The tthe builds gl. ing A ccopy oflshall the EPL display ca dthat the EPL an bepfound ncardaccu Append xratel RDthe plans R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance w ith the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third parry shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f) (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where using tight -fitting doors on factory -built fireplaces listed and labeledin accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square 1.5 /11doors no more than 0.5 t lwhen tested abeled o NFRC 400 or AMA/WDMA/CSA01%IS2/A44and 0by an accredited, independent laboratory and Is listed and by the manufacturer. Exception: Site -built windows, skylights and doors. 2020-Dec-29 15:09:13 Wright8of' " Right -Suite® U niversal 2021 21.0.02 RSU29066 Right -Energy® Florida 2017 Section 405.4.1 Compliant Software Page 7 Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) R402.4.4 Rooms containing fuel -burning appliances In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from Inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2, where the walls, floors and ceilings shalt meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent apliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. R R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing (Mandatory). All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air C403 2.9t2 offthe Commerc al shall Prrovsons of this code and nsidered ducts and shall be shown tenum o meet duct tightness l be rater a below. nd sealed in accordance with Section Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g), or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an.air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C) or below 55°F (13°C) shall be insulated to a minimum of R 3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be In accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. 0 R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be dedicated return pipe or a cold water supply pipe. Gravity and thermoslphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ElR403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or LIL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 2020-Dec-29 15:09:13 WtightSof#1 Right-Suite®Universal2021 21.0.02 RSU29066 Right -Energy® Flodda2017 Section405.4.1 Compliant Software Page hy, �.«� �,; ;�t 7 Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the Inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1 Storage water heater temperature controls. R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the Intended use. The minimum temperature setting range shall be from 100°F to 140oF (38°C to 60°C). ElR403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water heating system. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TMA, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. EDR403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation, including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved methodologies, heating and cooling calculation based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 unrrcn eeGruAnt1rA1 VFNTII ATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM CFM MINIMUM EFFICACY (a) CFM/WATT AIRFLOWRATEMAXIMUM Range hoods Any 2.8 cfm/watt Any In -line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt < 90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm - 28.3 L/min. (a) When tested in accordance HVI Standard 916 2020-Dec-29 15:09:13 - wrigjhtsaftO Right-Suite®Universal2021 21.0.02 RSU29066 Right -Energy® Fiorids2017 Section405.4.1 Compliant Software Page Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N MANDATORY REQUIREMENTS -(Continued) rl R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1 R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ElR403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls (Mandatory). Snow- and ice -melting systems, supplied through energy service to the building, shall include automatic controls capable of shutting off the systemw hen the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that w ill allow shutoff when the outdoor temperature is above 40°F (4.8°C). R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. rJR403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor- retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. ElR403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2020-Dec-29 15:09:13 wrightsoftO Right-Suite®Universal202121.0.02RSU29066 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page10 cai,a,Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N MANDATORY REQUIREMENTS - (Continued) R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with 1e Standard lilConditions-Low orreport ttlaboratory is quiredtoVifYproceduecompliance. Geotrmal swmming pol heat pumps are t required to eethsstandard. R403.11 Portable spas (Mandatory). The energy consumption of electric -powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS high -efficacy tlamps or not of lesment s (Mandatory). percent of thethan 75 per permanently installed lighting ercent of the fixs in tures shall permanently installed n only high efficacy lamfixtures ps. Exception: Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 2020-Dec-29 15:09:13 wlightsloftO Right -Suite@ U niversal 2021 21.0.02 RSU29066 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page11 ara3�ir�„;...Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R405-2017 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Spec Home Builder Name PSL Prop Street: Lot 20 Sunset Blvd Permit Office: City, State, Zip: Fort Pierce, FL 34982 Permit Number: Owner: Sppec Home Jurisdiction: St. Lucie Design Location: FL, St Lucie Co Intl COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA / V General A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope Air -permeable insulation shall not be used as a ❑ requirements contains a continuous barrier. Breaks or joints in the sealing material. air barrier shall be sealed. Ceilinglaftic The air barrier in any dropped ceiling/soffit The insulation in any dropped ceiling/soffit shall be aligned with the insulation and any shall be aligned with the air barrier. ❑ gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attics paces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed.The junction of the top plate Cavities with corners and headers of frame walls shall be insulated by completely filling the cavity and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 ❑ Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Windows, skylights The space between window/doorjambs and framing, and framing shall be sealed. ❑ and doors and skylights Rim joists are insulated and include an air Rim joists shall be insulated. ❑ Rim joists barrier. Floors (including The air barrier shall be installed at any exposed Floor framing cavity Insulation shall be installed to maintain permanent contact with the underside above -garage and cantilevered floors) edge of insulation. of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact ❑ with the top sideof sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with Where provided in lieu of floor insulation, insulation shall be permanently attached ❑ overlapping joints taped. to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft ❑ openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that ❑ on installation readily conforms to the available cavity spaces. Garage Air sealing shall be provided between the garage ❑ separation and conditioned spaces. Recessed Recessed light fixtures installed in the building Recessed light fixtures installed in the ❑ lighting thermal envelope shall be sealed to the drywall. building thermal envelope shall be airtight and IC rated. Plumbing and Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or wiring insulation that on installation readily conforms ❑ to available space shall extend behind piping and wiring. Shower/tub on The air barrier shall be installed behind Exterior walls adjacent to showers and tubs ❑ exterior wall electrical or communication boxes or air -sealed shall be insulated. boxes shall be installed. Electrical/phone The air barrier shall be installed behind ❑ box on exterior electrical or communication boxes or air -sealed walls boxes shall be installed. HVAC register HVAC register boots that penetrate building ❑ boots thermal envelope shall be sealed to the subfloor or drywall. Concealed When required to be sealed, concealed fire sprinklers sprinklers shall only be sealed in a manner that by the ❑ is recommended manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC400. 2020-Dec-29 15:09:13 014 rightsoft" Right -Suite® Universal2021 21.0.02 RSU29086 Right -Energy® Florida 2017 Section4054.1 Compliant Software Page 12 Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R405-2017 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: St. Lucie Permit Number: Job Information Builder: PSL Prop Community: Lot: Address: Lot 20 Sunset Blvd Unit: City: Fort Pierce State: FL Zip: 34982 Air. Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method. ❑ PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding Climate Zones 1 and 2. 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) In building or dwelling unit shall be tested and verified as having an air leakage rate of not PERFORMANCE or ERI METHOD exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or ElPERFORMANCE R406-2017 (ERI), section labeled as Infiltration, sub -section ACH50. ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): K, x60 _ 13784 = Method for calculating building volume: CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans ❑ PASS Code software calculated ❑ Field measured and calculated ❑ When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 2020-Dec-29 15:09:13 wrightsoft" Right -Suite® Universal 202121.0.02 RSU29066 Right -Energy® Florida 2017 Section 405.4.1 Compliant Software Page13 yura:�s da Wrightsoft HVACXLot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N FORM R405-2017 Duct Leakage Test Report Residential Perscriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: St. Lucie Job Information Permit Number: Builder: PSL Prop Community: Lot: Address: Lot 20 Sunset Blvd Unit: City: Fort Pierce State: FL Zip: 34982 Duct Leakage Test Results System 1 cfm25 System 2 cfm25 System 3 cfm25 Sum of any additional systems cfm25 Total of all systems cfm25 1602 Total of all Total Conditioned systems Square Footage ❑ PASS Qn ❑ FAIL ❑ Prescriptive Method cfm25 (Total) To qualify as "substantially leak free" Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Is the air handler unit installed ❑ YES ('_ 0.04 Qn) during testing? ❑ NO (<= 0.03 Qn) ❑ Performance / ERI Method cfm25 (Out or Total) To qualify using this method, Qn must be not greater than the proposed duct leakage Qn specified on Form R405-2017 or R406-2017. Leakage Type selected on Form Qn specified on Form R405-2017 R405-2017 (Energy Calc) or R406-2017 (Energy Calc) or R406-2017 Default Leakage Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statues. Testing Company Company Name: Phone: I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 2020-Dec-29 15:09:13 virrightsof#° Right -Suite® Universal 2021 21.0.02 RSU29066 Right -Energy® Florida 2017 Section405.4.1 Compliant Software Page 14 ,;.;. 6_i Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N Reference Home Characteristics Spec Home Title: Lot 20 Sunset Blvd PSL Prop Lot 20 Sunset Blvd Fort Pierce, FL 34982 FLBase2017 Above -grade Walls (Uo) 0.084 • Above -grade Wall Solar Absorptance 0.75 Above -grade Wall Infared Emittance 0.90 Basement Walls (Uo) n/a Above -grade Floors (Uo) n/a Slab Insulation R-Value 0.0 Ceilings (Uo) 0.030 Roof Solar Absorptance 0.75 Roof Infared Emittance 0.90 Attic Vent Area (ftZ) 5.34 Crawls pace Vent Area (ft2) n/a Exposed MasonryFloorArea (ft2) 404.40 Carpet & Pad R-Value 2.0 Door Area (ftz) 0.00 Door U-Factor n/a North Window Area (ftz) 0.00 South Window Area (ft2) 44.80 East Window Area (ft2) 44.80 West Window Area (ft2) 44.80 Window U-Factor 0.400 Window SHGC (Heating) 0.2169 Window SHGC (Cooling) 0.2169 ACH50 7.00 Internal Gains * (Btu/day) 68334 Water heater gallons per day 60.00 Water Heater set point temperature 120.00 Water heater efficiency rating 0.95 Labeled Heating System Rating and Efficiency HSPF = 8.2 Labeled Cooling System Rating and Efficiency SEER = 14.0 Air Distribution System Efficiency 0.88 Thermostat Type Manual Heating Thermostat Settings 72.0 (All hours) TMY City: FL —Fort —Pierce L 2 4l7 IMPORTANT A 10.0 PSF —NIT WITH . PSF " PSF, PSF BCDL' 10 PSF BCDL: PSF TOTAL' 37 PSF TOTAL PSF DURATION: 1.2 DURATION: CAUTIONM 1T ATTEMPT TO ERECT S WRHOUT REFERRING TO GINEEONG DRAWINGS AND SUMMARY SHEETS. TMANENT BRACING MUST BE ICE PRIOR TO LOADING M. Ile. SHEATHING, ES, ETC.) 1TERIOR BEARING WALLS RF. IN PLACE PRIOR TO REEK TO FINAL ENGINEERING SHEETS FOR THE FOLLO'MNG. 11 NNMBER OF GIRDER PLIES AND 2) BEARING BLOCK REOOIREMENTS, 3) SCAB DETAILS (IF REQUIRED) d) UPLIFT AND GRAVITY REACTIONS. WARNING Backcml— WIINot Be Accepts' Regardless Fault With out Prim NouRcaden Byy Customer Wi de Hours BY And InvesBgation By B.Hd.0 I.EX Fi KIONSw NO E%CEPTIONS. iM1e General C-Irsctor Is Responsible For All Connections 0-, TM1an Truss m Truss, Gable Shear Wall, And Connections. Temporary and Pemunent B—I'l And CeTng And Roe( Diaphragm Connactions. PORT SAINT LUCIE PROP RES: N!A MODEL SUNSET KEY m REVISIONS: 1. 2. 3. 6 ved And Neal Prlor To Ve TES ALL 1, FirstSouice RAVE 701 S. HINGS HIGMNAY FORT PIECE. FL 3 S Ph.(TT21•d61 54TS * wrightsoft° Load Short.i=orm House Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 EMail:Vlc4lym@aircalcs.com For: Spec Home, Air Conditioning Unlimited Lot 20 Sunset Blvd, Fort Pierce, FL 34982 Job: 1402 Date: Dec 29, 2020 By. Chris Bateman Htg Clg Infiltration Outside db (°F) 41 90 Method Simplified Average Inside db (OF) 70 75 Construction quality Design TD (°F) 29 15 Fireplaces Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/Ib) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S301A AHRI ref Coil ASPT39C14A AHRI ref 201785799 Efficiency 100 EFF Efficiency 13.0 EER,15.5 SEER 19600 Btuh Heating input 6.9 23456 kW Btuh Sensible cooling Latentcooling 8400 Btuh Heat ngoutput Temperature rise 23 OF Total cooling 28000 Btuh Actual airflow 933 0.042 cfm cfm/Btuh Actual airflow Air flow factor 933 0.046 cfm cfm/Btuh Air flow factor Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.78 ROOM NAME 82 Area (ft) Httg�load (Btuh) CIIg load (tgAVF �)VF M Hall 26 68 0 895 0 1000 0 38 0 46 Laundry Master Bath 90 1965 772 83 35 WIC 63 247 1589 1986 594 2290 67 84 27 105 Master Bed 0 0 0 0 Pantry Kitchen/Nook 15 275 3594 4809 152 220 Great Room 377 4730 6028 200 123 276 96 Bed 3 173 2897 2100 0 0 Hall 30 0 0 0 0 0 0 Lin Bath 8 50 728 398 31 18 3687 9422 156 111 Bed 2 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Dea29 15:11:28 -!}i- wrightsoft® Page 1 RightSute®Universal 202121.0.02RSU29066 /�+�...w6ghlsoftHVAQLot20Sunset Blvd PSLPropxup Caic=MJ8 FrontDoorfaces: N House Other equip loads Equip. @ 0.95 Latent cooling TOTALS 1602 22071 20414 933 933 1467 779 RSM 20218 5922 1602 23537 26140 933 933 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Dec-29 15:11:28 ti wrightsoft® Page 2 29066 Right-Stite®Udversal202121.0.02RSU �=...WrightsoftHVACtL.ot20SusetBlvd PSLProp x1p Calc=MJ8 Frort Door faces'. N Job: 1402 -�- Building Analysis Date: Dec 29,2020 wrightsoft" House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock LR Vero Beach, FL32966 Phone:772.800.8413 Email: vicldlynne@airmlcs.com For: Spec Home, Air Conditioning Unlimited Lot 20 Sunset Blvd, Fort Pierce, FL 34982 on: Location: Indoor: Indoor temperature (°F) Heating Cooling St Co Intl, FL US , Elevation: ft Design TD (°F) 29 30 15 50 Latitude: 28°N Outdoor: Heating Cooling Relative humidity (%) Moisture difference (grAb) 2.4 56.9 Dry bulb (°F) 41 Dail range °F - 90 15 ( L ) Infiltration: Method Simplified Wet bulb (°F)) - 77 Construction quality Average 0 Wind speed (mph) 15.0 7.5 Fireplaces Component Btuhfft2 Btuh % of load Walls 3.1 4371 18.6 Glazing 18.2 3253 13.8 Doors Ceilings 0 1.0 0 1588 0 6.7 Floors 3.4 5392 22.9 Infiltration 2.0 2782 11.8 Ducts 4684 19.9 Piping 0 0 Humidification 0 0 Ventilation 14677 6.2 Adjustments Total 23537 100.0 Component Btuh/ftZ Btuh %of load Walls 1.9 2715 12.8 Glazing 20.6 3700 17.5 Doors 0 0 0 Ceilings 1.8 2891 13.6 Floors 0 0 0 Infiltration 0.6 778 3.7 Ducts 5311 25.1 Ventilation 779 3.7 Internal gains 5020 23.7 Blower 0 0 Adjustments 0 Total 211931 100.0 Latent Cooling Load = 5922 Btuh Overall U-value = 0.105 Btuh/ft2 °F Data entries checked. Infiltration Gains 2020-Dec-29 15:11:28 411- wrightsoft" Page 1 A=- �,..�.•+gym-> Right -sate® Universal 202121.0.02 RSU29066 +M...WrightsoftHVAQLot20ScrsetBlvd PSLProp.rp Calc=MJ8 Front Door faces: N Job: 1402 -I'�- Component Constructions Date: Dec 29, 2020 wrightsoft® House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vicldlynne@aircalcs.com For: Spec Home, Air Conditioning Unlimited Lot 20 Sunset Blvd, Fort Pierce, FL 34982 Indoor: Heating Cooling Location: St Lucie Co Intl, FL, US Indoor temperature (OF) 70 75 15 Elevation: 26 ft Design TD (OF) Relative humidity (%) 29 30 50 Latitude: 280N Outdoor: Heating Cooling Moisture difference (grAb) 2.4 56.9 Dry bulb (OF) 41 90 15 (L Infiltration: ) Method Simplified Daily range (OF) - Wet bulb (OF) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U value Insul R ft' Btuh/Wl' ftk*F/Btuh Htg HTM Btuh/ft' Loss Clg HTM Gain Btuh Btuh/ft' Btuh Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd inl, 8" Thk, 1/2" Gyp Bd Int Fnsh n 259 0.109 5.1 3.15 3.15 814 2.02 521 1395 2.02 892 e 443 0.109 5.1 s 239 0.109 5.1 3.15 755 2.02 483 w 268 0.109 5.1 3.15 844 2.02 540 all 1208 0.109 5.1 3.15 3807 2.02 2435 Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" 192 0.101 11.0 2.94 564 1.46 280 OC Stud Windows Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); n 10 0.580 0 16.8 160 11.5 109 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (3.17 ft window ht, 1 ft sep.); 8 ft head ht Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); a 31 0.580 0 16.8 525 28.1 878 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft wndow ht, 1 ft sep.); 8 ft head ht Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.21); a 48 0.650 0 18.8 905 13.1 627 foreground = green grass (0.23); 10 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); s 5 0.580 0 16.8 76 13.5 61 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green (0.23); 1 ft overhang (2.08 ft window ht, 1 ft sep.); 8 ft head ht grass Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.22); w 22 0.620 0 18.0 403 16.8 377 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 6 ft overhang (5.17 ft window ht, 1 ft sep.); 8 ft head ht Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.22); w 16 0.620 0 18.0 280 27.2 424 Impact, 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 8 ft head ht 411- wrightsoft® Universal 2021 21.0.02 RSU29066 2020.-Deo-2915:11:28 Page 1 RightSute® AC.I�P� WrightsoftHVAC\Lot20SLmetBlvdPSLProp.np Calc=MJ8 FrortDoorfaces: N Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); w foreground = green grass (0.23); 9.1 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht 11 Doors (none) Ceilings Attic, Shngis, R-30 Roof Ins, 1/2" Gyp Bd Int Fnsh Floors On Grade Depth, Tile Fir Fnsh 48 0.650 0 18.8 905 14.8 711 1602 0.034 30.0 0.99 1588 1.80 2891 188 0.989 0 28.7 5392 0 0 2020-Deo-29 15:11:28 wrightsoft® Page 2 �, RightStite®Universal 2021 21.0.02 RSU29066 g ��...WrighlsoftWAQLot20SirsetBlvd PSLProp.np Calc=MJB Front Door faces: N Job: 1402 -l�- Project Summary Date: Dec 29, 2020 Wrightsoft® House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln. Vero Beach, FL32966 Phone: 772.800.8413 Email: vick llYnre@aircZl s.com limited For: LSpec ot 20 Sunsett Blvd, Fort Piee Air rce, nFL 34982 Notes: Weather: St Lucie Co Inti, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 F 70 ° Outside db Inside db 90 OF 75 OF °F Inside db Desi n TD g °F 29 F Design TD 15 L Daily range Relative humidity o 50 /o Moisture difference 57 gr/lb Sensible Cooling Equipment Load Sizing Heating Summary Structure 17386 Btuh Structure Ducts 15103 Btuh 5311 Btuh Ducts Central vent (46 cfm) 4684 Btuh 1467 Btuh Central vent (46 cfm) 779 Btuh Outside air 0 Btuh Outside air Blower 0 Btuh Humidification 0 Btuh Piping Equipment load 23537 Btuh Use manufacturers data Rate/swingg multipplier n 0.95 Equipmentseri le load 20218 Btuh Infiltration Simplified Latent Cooling Equipment Load Sizing Method Construction quality Average Structure 2576 Btuh Fireplaces Ducts 1568 Btuh 1778 Btuh Central vent (46 cfm) Heating Coolingg 1602 1602 Outside air Equipment latent load 5922 Btuh Area (ft2) Volume (f13) 13784 13784Btuh 0.38 0.20 Equipment Total Load (Sen+Lat) 26144 Air changes/hour /houcfm) 87 46 Req. total capacity at 0.70 SHR ton 2.4 ton Equiv. AVF Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Trade GOODMAN Trade Cond GSX16S301A Model Coil ASPT39C14A AHRI ref AHRI ref 201785799 Efficiency 100 EFF Efficiency 13.0 EER,15.5SEER Sensible cooling 19600 Btuh Heating input Heatingoutput 6.9 kW 23456 Btuh Latent cooling 8400 Btuh 28000 Btuh Temperature rise 23 OF 933 cfm Total cooling Actual airflow 933 cfrn Actual airflow Airflowfactor 0.042 cfm/Btuh Airflowfactor 0.046 cfm/Btuh 0.70 in H2O Static pressure 0.70 in H2O Static pressure Load sensible heat ratio 0 78 Space thermostat Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Dec-29 15:11:28 wrfightsoTt® C Rlght-Stite®Universal 202121.0.02RSU29066Page 1 AOM ...WrightsoftHVAQW20SuisetBlvd PSLProprup Calc=MJ8 FrontDoorfaces: N Job: 1402 -l�I- wrightsoft° Rlght-J®W®rksheet Date: Dec 29, 2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800,8413 Email: vicldlynne@aircalcs.com House M Hall 1 Room name 188.0 ft 4.0 ft 2 F)posed wall 8.6 ft 8.0 ft heat/cool 3 Room height 4.0 x 6.5 ft 4 Room dimensions 1601.8 T 26.0 ft2 5 Room area r (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Ty Construction U-vaBtjh 3- Or Btu�z) number (Btuh� -°� ( ooreaperimet Gross N/P/S Heat Cool Gross N/P/S Heat Cool Heat Cool 268 10 259 0 814 160 521 109 0 0 0 0 0 0 0 0 6 yJ Blk Wall, Stu000 End 0.109 n 3.15 2.62 11.48 L-G Impact, ClearLow-e 0.580 n 16.82 0.109 a 3.15 2.02 522 443 1395 892 0 0 0 0 Blk Wall, Stump Ext 0.580 a 16.82 28.13 31 0 525 878 0 0 0 0 Impad, Clear Lowe Impad, Clear Lowe 0.650 a 18.85 13.06 48 44 905 627 0 0 0 0 0 0 yI Elk Wail, Stucco Fed 0.109 s 3.15 2.02 244 5 239 5 755 76 483 61 0 0 0 0 G� Impad,ClearLowe 0.580 s 16.82 13.48 0.109 w 3.15 2.02 354 268 844 540 0 0 0 00 Blk Wall, Stucco F)d 0.620 w 17.98 16.83 22 17 403 377 0 0 0 0 0 Impad, Clear Lowe 0.620 w 17.98 27.18 T�Impad,ClearLowe 16 0 280 424 711 0 0 0 0 0 0 �i ImpadCiearLowe 0.650 w 18.85 14.81 2.94 1.46 4.8 192 39 192 905 564 280 32 32 94 47 P Frm Wall,112" Gyp B 0.101 0.034 0.99 1.80 1602 1602 1588 2891 26 26 26 47 0 C Attiq Shngls, R-30 F On Grade Depth, Tile 0.989 28.68 0.00 1602 188 5392 0 26 4 115 6 AED excursion 514 -5 c) 14604 9306 235 89 Envelope loss(gain 2782 778 0 0 12 a) Infiltration b) Room ventilation 0 0 0 0 Internal gains: Occupants @ 230 4 920 4100 0 0 0 13 Applianceslother 17386 15103T'., 235 89 Subtotal (lines 6 to 13) 0 00 0 Less extemal load 0 00 0 Lessiransfer 0 0235 -89 Redistribution 17386 151030 0 14 15 Subtotal Dud loads 27% 35% 4684 5311 27%0 0 22071 20414 0 0 0 Total room load Air required (dm) 933 933 1 0 Calculations approved b ACCAto meet all requirements of Manual J 8th Ed. 2020-Dec29 15:11:28 -I�i- wrtghtsoft'° �P. RightStiteOUruversa1202121.0.02RSU29066Page 1 Calc=MJ8 Front Door faces: N ...WrightsoftHVAClLot20SusetBlvdPSLProprg7 Job: 1402 -I�d- wrightsofty Right-J®Worksheet Date: Dec29, 2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vera Beach, FL32966 Phone: 772.800.8413 Email:vicldlynne@aircalcs.com Laundry Master Bath 1 Room name 10.5 ft 21.5 ft 2 Exposed wall 8.0 ft heaticool 8.0 ft heaVocol 3 Room height 10.5 x 6.5 ft 7.5 x 12.0 ft 4 Room dimensions 683 ft' 90.0 ftz 5 Room area U-value °F) Or HTM Area (1112) (ft) Load (Btuh) Area (ft) or perimeter (ft) Load (Btuh) Ty Construction number (Bllih/ft? (Btuh/ft-) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 0.109 n 3.15 2.02 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 y/ BIk Wall, Stucco Ext L-C' ImpactClea�Low-e 0.580 n 16.82 11.48 0 0 0 0 16 16 50 32 Val Blk Wall, Stucco Ext 0.109 e 3.15 2.02 0 0 0 0 0 0 0 0 I-� Clear Lowe 0.580 a 16.82 28.13 0 0 0 0 0 0 0 0 11 L-G impact, Clear Lowe impact, 0.650 a 18.85 13.06 0 0 0 96 91 288 1 y/ L BIk Wall, Stucco Ext Impact, Clear Lowe 0.109 0.580 s s 3.16 16.82 2.02 13.48 0 0 0 0 0 0 5 12 5 12 76 30 61 61 20 -_G BIk Wall, Stucco Ext 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 0 Impad,Clear Lowe 0.620 w 17.98 16.83 0 0 0 0 0 0 0 0 Impad, Clear Lowe 0.620 w 17.98 27.18 0 0 0 0 0 0 0 0 Impact, Clear Lowe Fnn Wall,lf2" Gyp B 0.650 0.101 w 18.85 2.94 14.81 1.46 84 84 247 123 48 90 48 90 141 89 70 16 P C Attic, Shngls, R-30 0.034 0.99 1.80 68 68 68 11 fib 301 123 0 90 22 617 0 F On Grade Depth, Tile 0.989 28.68 0.00 6 AED excursion -40 -32 c) 616 206 1299 502 Envelope loss/gain 0 0 249 69 12 a) Infiltration b) Room ventilation 0 0 0 0 Internal gains: Occupants @ 230 0 500 0 0 0 13 Applianceslother 616 706 1548 571 Subtotal (lines 6 to 13) 0 0 Less extemalload 0 p 0 0 Less transfer 90 34 0 0 Redistribution 705 740 1548 571 14 15 Subtotal Dudloads 27% 35% 190 260 27% 350 417 201 1983 772 35 Total room load 83g 1046 83 35 Air required (cim) Calculations approved IDACCAto meet all requirements of Manual J 8th Ed. 2020-Deo-2915:11:28 -1+1- wrlightsoft^' Rig ht-StiteOUruversa12021 21.0.02 RSU29066Page 2 N ...WrightsoftHVAQLot20SutisetBlvdPSLProp.rip Calc=MA Front Door faces: Job: 1402 -�- wrightsoft° Right-.1® WorkSheet Date: Dec 29, 2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email: vicldlyrm@aircalcs.com WIC Nester Bed 1 2 Room name Exposed wall 8.0 ft 170 ft heat/cool 8.5 ft 14.5 ft heaV000l 3 Room height 5.5 x 11.5 It 14.5 x 17.0 ft 4 Room dimensions 63.3 ft' 246.5 ft 2 5 Room area Ty Or (Btuh�2) orperimeter(ft) Load (BWh) Area or (ft) perimeter (ft) Load (Btuh) number (Btuh�z°F) Gross N/P/S Heat Cool Gross N/P/S Heat Cool Heat Cool yJ BIk Wall, Stucco Ext 0.109 n 3.15 2.02 0 0 0 0 0 0 0 0 0 0 0 0 0 6 L-G Impact, Clear Lowe 0.580 n 16.82 11A8 0.109 a 3.15 2.02 44 44 139 80 123 100 439 V� BIk Wall, Swoon Ext 0.580 a 16.82 28.13 0 0 0 262 0 0 11 F-G Impact Clear Lowe _G Impact, Clear Lowe 0.650 a 18.85 13.06 0 0 0 2900 0 180 0 0 y/ BIk Wall, Stucco E)d 0.109 s 3.15 2.02 16.82 13.48 92 0 92 0 0 0 0 0 L--G Impact,Clearl-owe VV��11 Blk Wall, Stucco E:d 0.580 s 0.109 w 3.15 2.02 0 0 0 0 0 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.620 w 17.98 16.83 17.98 27.18 0 0 0 0 0 0 0 0 0 0 0 Impact, ClearLO%" 0.620 w 0.650 w 18.85 14.81 0 0 0 0 0 0 0 0 0 0 Impact Clear Lowe P Frm Wall,1)Z' Gyp B 0.101 2.94 1.46 0 0 63 0 63 0 114 0 247 0 247 244 445 C Attic, Shngis, R-30 0.034 0.99 1.80 28.68 0.00 63 63 17 488 0 247 15 416 0 F On Grade Depth, Tile 0.989 -25 4 6 c) AED excursion 979 364 1262 11!69 Envelope loss/gain 273 76 247 12 a) Infiltration 0 0 0 b) Room ventilation 13 Internal gains: Occupants@ 230 0 0 0 0 0 500 Appliancestother 1251 440 1509 1673 Subtotal (lines 6 to 13) 0 0 0 0 Less external load 0 0 0 0 Lesstransfer 55 21 Redistribution 1251 440 1564 1694 14 Subtotal 27% 35°/u 337 155 270 35% 421 596 15 Ducloads Total room load 1589 67 594 27 1986 84 2290 105 Air required (dm) Calculations approved b ACCAto meet all requirements of Manual J 8th Ed. 2020-Deo•2915:11:28 -!}i- wrYghtsoft• • v '- Right-Stite®Universal 2021 21.0.02 RSU29066 Page 3 Calc=MJB Front Door faces: N ..WrightsoftHVAC1Lot20Su1setBlvdPSLProp.rup -I�I- wrightsoft9 Right-M Worksheet House Job: 1402 Date: Dec 29, 2020 By. Chris Bateman Air Calcs, LLC c! nnnaa oi,—:77� 800 8411 FmA1, %. rldlvnne0)aircals.00m 'aournouennaiuniunuy�o�.,�o..,� .....................—'----. _ _ - Pantry Ntchen/Nook 1 Room name 0 It 23.5 It 2 Exposed wall 8.0 ft heat/cool 9.3 ft heaUmol 3 Room height 5.0 x 3.0 ft 1.0 x 274.5 ft 4 Room dimensions 15.0 ft 274.5 ft= 5 Room area Ty Construction U-value Or HTM Area (ft2) (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (B1uh) number (Btuh/ft2-°F) (Btuh/ft2) or perimeter Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 V?/ Blk Wall, Stu000 Ext 0.109 n 2.02 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 L __G Impact Clear Lowe 0.580 n 11 A8 0 0 0 0 0 219 171 537 344 U�V Blk Wall, Stucco Ext 0.109 a 2.02 28.13 0 0 0 0 0 00 0 I—� Impact, Clear Lowe impact 0.580 a F16 0 0 0 0 48 44 905 627 1 L—G ClearLow-e 0.650 a 13.06 0 0 0 0 0 0 �/�JBlk Wall, Stump EA 0.109 s 2.02 0 0 0 0 0 00 0 L--G Impact, ClearLow-e 0.580 s 13.48 00 0 0 0 0 0 0 0 W�i Blk Wall, Stuom Ext 0.109 w 2.02 0 0 0 0 0 0 0 0 Impact, Clear Low-e 0.620 w8 16.83 0 0 0 0 0 0 0 0 Impact, ClearLow-e 0.620 w8 27.18 0 0 0 0 0 0 0 Impact ClearLow-e 0.650 w5 14.81 0 0 0 0 0 0 0 0 0 P. Frm Wall, IW Gyp B 0.101 - 2.94 0.99 1.46 1.80 0 15 15 15 27 275 275 272 495 C Attic, Shngis, R-30 0.034 - 0 0 0 275 24 674 0 F On Grade Depth, Tile 0.989 - 28.68 0.00 15 1 -199 6 c) AED excursion 15 26 2388 1267 Envelope loss/gain 0 0 438 12 12 a) Infiltration 0 0 0 0 0 b) Room ventilation Internal gains: Occupants @ 230 0 0 0 2 4fi0 1700 13 Applianosslother 15 26 2826 3549 Subtotal (lines 6 to 13) 0 0 0 Less external load p 0 0 Less transfer -15 -26 5 9 Redistribution 0 0 2832 3558 14 Subtotal 27% 35% 0 0 27% 350/0 763 1251 15 Duct loads ' 3594 4809 Total room load p 152 220 Air required (cIm) Calculations approved byACCAto meet all requirements of Manual J 8th Ed. I�t- wrigF�tsoTt� 2020-Deo-2915:11:28 )'f Right-Sute®Universal 202121.0.02RSU29066 Page ...WrighlsoftHVAQLot20Su1setBlvd PSLProp.nQ Calc=MJ8 Front Door faces: N Job: 1402 wrightsofta Right-J® Worksheet Date: Dec 29, 2020 House By. Chris Bateman Air Calcs, LLC 7650 Hidden Hammock Ln Vero Beach, FL32966 Phone: 772.800,8413 Email: vickilynne@aircalcs.com Great Room Bed 3 1 Room name 29.0 ft 27.0 ft 2 Exposed wall 9.3 ft heaUcool 8.0 ft heaU000l 3 Room height 26.0 x 14.5 ft 1.0 x 1725 ft 4 Room dimensions 377.0 tt' 172.5 5 Room area Ty Construction U-value °F) Or HTM Area (T) (ft) Load (Btuh) 2) Area (ft') or perimeter (ft) Load (Btuh) number (BtuhAF (Btuh/ftz) or perimeter Heat . Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V1J Blk Wall, Stucco F)d 0.109 n 3.15 2.02 0 0 0 0 0 0 96 0 96 0 302 0 193 0 L--G Impact, Clear Lowe 0,580 n 16.82 11 A8 0 0 0 0 0 0 120 104 329 210 VL Blk Wall, Slu000 Ext 0.109 a 3.15 2.02 0 0 0 16 0 262 439 �mpact, Clear Lowe 0.580 a 16.8285 28.13 0 0 0 0 0 0 0 0 i mpact Clear Low-e 0.650 a 18. 13.06 0 0 0 0 0 0 0 -G yJ Blk Wall, Stucco E)d 0.109 s 3.15 2.02 0 0 0 0 0 0 0 0 0 0 L-G Impaa Clear WALe 0.580 0.109 s w 16.82 3.15 13.48 2.02 242 171 540 345 0 0 0 0 Vh Blk Wall, Stucco Ext 0.620 17.98 16.83 22 17 403 377 0 0 0 0 Impact, Clear Low-e Impact, Clear Lowe 0.620 w w 17.98 27.18 0 0 0 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.650 w 18.85 14.81 48 28 39 28 905 82 711 41 0 0 0 0 0 PIFrm Wall,1/2" Gyp B 0.101 - 2.94 0.99 1.46 1.80 377 377 374 680 173 173 171 311 C F Attic, Shngls, R-30 On Grade Depth, Tile 0.034 0.989 - - 28.68 0.00 377 29 832 0 173 27 774 0 748 11 6 c) AED excursion 3135 2902 1839 1165 Envelope loss/gain 4800 1300 433 121 12 a) Infiltration 0 0 b) Room ventilation 13 Internal gains: Occupants @ 230 2 460 900 0 0 250 Appliancustother 3620 4397 2272 1536 Subtotal (lines 6to 13) 0 0 0 0 Less external load 0 0 Less transfer 106 62 10 17 Redistribution 3726 4460 2282 1554 14 Subtotal 27% 35% 1004 1568 27% 35% 6151 546 15 Dud loads 4730 6028 2523 2196 Total room load 200 276 Air required (dm) Calculations approved byACCAto meet all requirements of Manual J 8th Ed. tr{.t wrightsoft� 2020-Dec-2915:11:28 Right-Sute®Unversal 2021 21.0.02 RSU29066 Page 5 ...WrightsoftHVAC1Lot20Sunset Blvd PSLPropxup Calc=MJ8 Front Door faces: N Job: 1402 -I+I- wrightsoft' Right-J® Worksheet Date: Dec 29, 2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock LR Vero Beach, FL32966 Phone: 772.800.8413 Email:,AcW]ynne@alrcalcs.com Hall Lin 1 Room name 2 E)posed wall 8.0 ItheaUcool O ft 8.0 Itheatl000l O ft 3 Room height 3.5 x 8.5 It 2.5 x 3.0 ft 4 Room dimensions 29.8 ft2 7.5 ft2 5 Room area Ty Conshvclion U-value Or Areaperimet (ft) Load (Btuh) Area (ft) or perimeter (ft) Load (B�h) number BHHTMM2) (Btuh/F oF) r Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 \tBlk Wall, Stucco F)d 0.109 n 3.15 2.02 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 L -� Impact ClearLov.e 0.580 n 16.82 11.48 3.15 2.02 0 0 0 0 0 0 0 0 VL1 Blk Wall, Stucco Ext 0.109 a 16.82 28.13 0 0 0 0 0 0 I-{ Impact, Clear Lowe 11 �G ImpaMClearLowe 0.580 a 0.650 a 18.85 13.06 0 0 0 0 0 Q 0 0 0 �/ Blk Wall, Stucco Ext 0.109 s 3.15 2.02 16.82 13A8 0 0 0 0 0 0 0 0 0 0 0 0 L--G Impact, Clear Lowe Blk Wall, Sturm Ext 0.580 s 0.109 w 3.15 2.02 0 0 0 0 0 0 0 C 0 0 0 J�:Impact, Clear impact, 0.620 w 17.98 16.83 17.98 27.18 0 0 0 0 0 0 0 0 0 0 G Clear Lowe 0.620 w 0.650 w 18.85 14.81 0 0 0 0 0 0 0 0 0 0 0 Impad,Clear Lowe P Frm Wall, Gyp B 0.101 2.94 1.46 0 30 0 30 0 29 0 0 8 8 7 14 C Atllc, Shngls, R-30 0.034 0.99 1.80 30 0 0 0 8 0 0 0 F On Grade Depth, Tile 0.989 - 28.68 0.00 _3 1 6 c) AED excursion 7 13 29 51 Envelope losstgain 0 0 0 0 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 13 Internal gains: Occupants @ 230 0 0 0 0 0 Applianoestother 29 51 7 13 Subtotal (lines 6 to 13) 0 0 0 0 Less external load 0 0 0 0 Less transfer 2g -51 -7 -13 0 Redistribution 0 0 0 0 14 Subtotal 27% 35% 0 0 27% 35% 0 15 Duct loads Total room load 0 0 0 0 0 0 0 0 ' Air required (dm) Calculations approved b ACCAto meet all requirements of Manual J 8th Ed. 2020-Dec-29 15:11:28 wrightsoft' Right-Sute®Universal 202121.0.02RSU29066 Page 6 Sunset Blvd PSLProp.rup Calc=MJB FrontDoorfaces: N WdghtsoftHVAQLot20 -i}t- wrightsoft, Right-J® Worksheet Job: 1402 House Date: Dec 29, 2020 By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email:,Addlyye@aircaics.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Bath 5.5 ft 8.0 It heaV000l 9.0 x 5.5 It 49.5 ft= Bed 2 35.5 ft 8.0 It heat/cool 1.0 x 182.0 ft 182.0 ft' Ty Construction number U-value (Btuh/ft? °F) Or HTM (Bbi F) Area (ft) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Stuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V�1 �G Blk Wall, Stucco E)d Impac , Clear Low-e Blk Wall, Stu000 Ext Impact, ClearLow-e Impact, Clear Lowe Blk Wall, Sfucoo Ext Impac,Clear Low-e Blk Wall, Stucco Ext Impact Clear Low-e Impact, Clear Lowe Impact Clear Lowe Frm Wall, lf2° Gyp B Attic, Shngls, R-30 On Grade Depth, Tile 0.109 0.580 0.109 0.580 0.650 0.109 0.580 0.109 0.620 0.620 0.650 0.101 0.034 0.989 n n a a a s s w w w w - - - 3.15 16.82 3.15 16.82 18.85 3.15 16.82 3.15 17.98 17.98 18.85 2.94 0.99 28.68 2.02 11.48 2.02 28.13 13.06 2.02 13.48 2.02 16.83 27.18 14.81 1.46 1.80 0.00 44 10 0 0 0 0 0 0 0 0 0 0 50 50 35 0 0 0 0 0 0 0 0 0 0 0 50 6 109 160 0 0 0 0 0 0 0 0 0 0 49 168 70 109 0 0 0 0 0 0 0 0 0 0 89 0 128 0 0 0 0 56 0 100 0 16 0 0 182 182 128 0 0 0 0 56 0 84 0 0 0 0 182 36 403 0 0 0 0 176 0 266 0 280 0 0 180 1018 258 0 0 0 0 113 0 170 0 424 0 0 328 0 II�--GGG yJ L--G VV��11 �--G P C F 6 c)AEDexcursion -16 72 Envelope loss/gain 475 252 2325 1366 12 a) Infiltration b) Room ventilation 88 0 25 0 569 0 159 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 250 Subtotal (lines 6 to 13) 564 277 2894 1775 14 15 Less extemalload Lesstransfer Redistribution Subtotal Ductloads 1 27% 35%1 0 0 10 574 155 0 0 17 294 103 27% 35%1 0 0 10 2904 7821 0 0 17 1792 630 Total room load Air required (clm) 728 31 398 18 3687 156 2422 111 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -rw 2020-Dec-2915:11:28 Rig ht-Sute@Universal 202121.0.02RSU29066 Page WrightsoftHVAC1Lot20Su1setBlvd PSLProp.rup Calc=MJ8 Front Door faces: N -I'�- wrightsofte Duct System Summary House Air Caics, LLC 7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vicld"@aircais.com For: Spec Home, Air Conditioning Unlimited Lot 20 Sunset Blvd, Fort Pierce, FL 34982 Extemal static pressure Pressure losses Available static pressure Supply return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.70 in H2O 0 in H2O 0.70 in H2O 0.559 / 0.141 in H2O 0.291 in/100ft 933 cfm 240 Job: 1402 Date: Dec 29, 2020 By. Chris Bateman Cooling 0.70 in H2O 0 in H2O 0.70 in H2O 0.559 / 0.141 in H2O 0.291 in/100ft 933 drn Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath h 728 37 22 0.311 4.0 Ox 0 VIFx 44.8 135.0 st3 Bed 2 h 3687 187 133 0.291 7.0 Ox 0 VIFx 51.8 140.0 st3 Bed 3 h 2897 147 115 0.294 7.0 OX 0 VI FX 49.9 140.0 st3 Great Room c 3014 120 165 0.383 7.0 Ox 0 VIFx 36.0 110.0 st2 Great Room -A c 3014 120 165 0.381 7.0 OXO VIFx 36.8 110.0 st2 KitchervNook c 2404 91 132 0.380 6.0 Ox 0 VIFx 37.0 110.0 st2 KitchenNook-A C 2404 91 132 0.383 6.0 Ox0 MFx 36.0 110.0 st2 Laundry c 1000 45 55 0.656 4.0 OX 0 VIFx 5.2 80.0 Master Bath h 1965 100 42 OA64 5.0 Ox0 VIFx 20.3 100.0 st1 Master Bed c 1145 50 63 0.475 5.0 OX 0 VI FX 22.6 95.0 st1 MasterBed-A c 1145 50 63 0.487 5.0 Ox0 VIFx 19.8 95.0 st1 Wic h 1589 81 33 0.486 5.0 Ox0 VIFx 20.0 95.0 st1 Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk Name st1 st3 st2 PeakAVF PeakAVF PeakAVF 281 371 793 201 270 865 0.464 0.291 0.291 805 840 809 8.0 9.0 14.0 0 x 0 0 x 0 0 x 0 VinIFIX VinIFIX VinlFlx st2 �. AWCI jhtSOft® Right-Suite®Universal 2021 21.0.02 RSU29066 ...WdghtsoftHVAC1Lot20SusetBlvdPSLProp.nQ Calc=MJB FrontDoorfaces: N 2020-Dec-29 1 b:1129 Page 1 Grille Htg Jame Size (in) (cfm) rb5 Ox0 181 rb6 Ox 0 605 rb4 Ox 0 187 rb3 Ox 0 147 TEL A Design FR Veloc (fpm) Diam (in) H x W (in) Stud/KF OpeninMatk Clg (Cfm) 158 714 133 115 48.5 0 0 0 0.291 0 0 0 520 0 0 0 80 0 0 0 Ox 0 Ox 0 Ox 0 Ox 0 VIFx VIFx Boldldalic values have been manually overridden 2020-Dec-29 15:11:29 wrightsoft® Page 2 ti A—k-(Bslk IIIlV -YAP- Right-Sute®Uriversal2021 21.0.02 RSU29066 .,WrightsoftHVACIot20SusetBlvd PSLProp.ryp Calc=MJ8 FrorADoorfaces: N Job: 1402 - wrightsoft® Manual S Compliance Report Date: Dec 29, 2020 House By. Chris Bateman Air Calcs, LLC 7550 Hidden Hammock LR Vero Beach. FL32966 Phone: 772.800.8413 Email: vicldlyme@aircalcs.com For: Spec Home, AirConditioningUnlimited Lot 20 Sunset Blvd, Fort Pierce, FL 34982 Design Conditions Outdoor design DB: 90.4°F Sensible gain: 21193 Btuh Outdoor design WB: 77.4°F Latent gain: 5922 Btuh Indoor design DB: 75.0°F Total gain: 27115 Btuh Indoor RH: 50% Estimated airflow: 933 clip Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SPIitAC Manufacturer: Goodman Mfg. Actual airflow: 933 chn Sensible capacity: 19600 Btuh Latent capacity: 8400 Btuh Total capacity: 28000 Btuh Model: GSX16S301A+ASPT39C14A 92% of load 142% of load 103% of load SHR: 70% Design Conditions Outdoor design DB: 41.0°F Heat loss: 23537 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Elecstrip Manufacturer: Model: Actual airflow: 933 cfm Output capacity: 6.9 kW 100% of load Meets all requirements ofACCA Manual S. Entering coil DB: 76.9°F Entering coil WB: 64.1OF Entering coil DB: 68.0°F Temp. rise: 50 OF • 2020-Dec-2915:11:29 ` -� wrightsoft® Page 1 �� w�,.�•en.,w..�.n...,�wro RightStite®Uruversa1202121.0.02RSU29066 9 ...WrightsoftHVAC1Lot20SusetBlvdPSLProp.rLp Calc=MJ8 Front Door faces: N C Level 1 m ��F - - pltx12 ---a— b —,WOE e10X0; b• r- : _ ' 1171 r-r,88d3a, r_ ` 11000X�1D is a y IUtChanliJ001C 110 do vfi awm 6• 1 ..---- - x6 33&n �T 6 - '-, eMastarS dd Brr'�uri■ciuAc - a 5- S• ' X. •6 100 we ®« 1�Xi&• � PA FIal6 F P Great Room �, k 10z10' 9 fr6'.- :r<u•10 do . ift El1� 1 do • _ �s �' BEDROOM ■1 , • '�' � I rrPwr�aw i g�SQ ®1\ Ig ■ q 'NIX`Z}'1 IV` TffIW- _ _ _ _ _ _ _ _ - � � 1 ff Pam• --a „ -- . x52H Lauri dryer �" Master'Bal .3 - mxnw __ _ .9•IN N.YTx = `V •Y as AYP iNOTE, P+wE• PYPOPNYLPE NR. P1Y�iA0YNCT0 /JIYE PIPE rage Ga. .;I >.. � ]] n Job M 1402 Performed by Chris Bateman for: Spec Home Lot 20 Sunset Blvd Fort Pierce, FL34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale:1 :136 Page 1 RightSuite® Universal 2021 21.0.02 RSU29066 2020-Dec-29 15:11:43 ALot 20 Sunset Blvd PSL Prop.rup 1. . N Job #: 1402 Performed by Chris Bateman for: Spec Home Lot 20 Sunset Blvd Fort Pierce, FL 34982 Level 1 Air Caics, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale:1 :126 Page 1 Right Suite® Universal2021 21.0.02 RSU29066 2020-Deo-2915:07:59 \Lot 20 Sunset Blvd PSL Prop.rup