HomeMy WebLinkAboutEnergy CodeFORM R405-2017
is
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Spec Home
Builder Name: PSL Prop
Street: Lot 20 Sunset Blvd
Permit Office:
City, State, Zip: Fort Pierce, FL 34982
Permit Number:
Owner: Spec Home
Jurisdiction: St. Lucie
Design Location: FL, St Lucie Co Intl
County: St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall types (1580 ft2)
Insulation (R) Area (ft2)
2. Single family or multiple family Single -Family
a. Frm Wall, 1/2" Gyp Bd Ext, R-11
b: Blk Wall, Stucco Ext, R-4.1 Ext
11.0 191.90
4.1 1387.60
3. Number of units, if multiple family 1
C. N/A
4. Number of bedrooms 3
d. NIA
10. Ceiling types (1602 ft2)
Insulation (R) Area (ft2)
5. Is this a worst case? Yes
a. Attic, Shngls, R-30 Roof Ins, 1/
30.0 1601.75
6. Conditioned floor area above grade (ft2) 1601.75
b. N/A
Conditioned floor area below grade (ft2) 0
c. N/A
R Area (ft2)
7. Windows (179 ft2) Description Area (ft2)
11. Ducts
a.Sup: House Attic, Ret: House Attic, AH: House 6.0 318.54
a. U-Factor: Dbl Impact, 0.580 45.21
b.
SHGC: 0.24
b. U-Factor: Dbl Impact, 0.650 48.00
12. Cooling systems
kBtu/hr Efficiency
28.0 SEER: 15.5
SHGC: 0.21
a.Split air conditioner
c. U-Factor: Dbl Impact, 0.620 37.99
b•
13. Heating systems
kBtu/hr Efficiency
SHGC: 0.22
d. U-Factor: Dbl Impact, 0.650 48.00
a.Electric strip
23.5 AFUE: 100.0
SHGC: 0.24
b'
Area Weighted Average Overhang Depth: 6.205 ft
Area Weighted Average SHGC: 0.228
14. Hot water systems
a.Electric conventional (40 gal)
Cap: 40 gal
EF: 0.96
8. Floor types (1601.75 ft2) Insulation (R) Area (ft2)
b.Conservation features
a. On Grade Depth, Tile Fir Fnsh 0.0 1601.75
(None)
b. N/A
C. N/A
15. Credits None
0.112 Total Proposed Modified Loads: 46.35
PASS
Glass/Floor area:
Total Baseline Loads: 49.00
I hereby certify that the plans and specifications covered by
Review of the plans and specifications
'C��
this calculation are in compliance with the Florida Energy
covered by this. calculation Indicates
compliance with the Florida Energy
"'__
Code.
cluz ' Ua&m-'�
Cade. Before construction is completed,
for
PREPARED BY.
this building will be inspected
compliance with Section 553.908
DATE: 12/29/2020
Florida statutes.
f
I hereby certify that this building, as designed, is in
1r`
compliance with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
x
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
2020-Dec-29 15:09:13
WrilghtSo't' RightSuite®Universal2021 21.0.02 RSU29066 Right -Energy® Florida2017 Section405.4.1 Compliant Software Paget
fff t;jc�r�� Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
,, Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential
Simulated Performance method shall include:
14
❑ This Checklist
❑ A FORM 405 report that documents that the Proposed Design complies with Section R405.3 of the Florida
Energy Code. This form shall include a summary page indicating home address, a -ratio and the pass or fail
status along with summary areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual completing the compliance
report (one page).
❑ An input summary checklist that can be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level (EPL) Display Card (one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements (five pages)
Required prior to CO for the Performance method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table 402.4.1.1 - one page)
❑ A completed Form 2017 Envelope Leakage Test Report (usually one page). Section R402.4 or R402.4.1.2
exceptions may apply.
❑ If FORM R405 duct leakage type indicates anything other than "default leakage", then a completed FORM R405
Duct Leakage Test Report (usually one page).
2020-Dec-29 15:09:13
Wright oft- Right -Suite® Universa1202121.0.02 RSU29066 Right -Energy® Florida2017 Section405.4.1 Compliant Software Pagel
y,�,r� ...Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
Building Inout Summary Report
PROJECT
Title: Sppec Home
Bedrooms: 3
Address type:
Lot#:
Street
address
Building Type: FLAsBuilt
Spec Home
Bathrooms: 2
Conditioned Area: 1602
Block/Subdivision:
Owner:
# of Units: 1
Total Stories: 1
Worst Case: Yes
Platbook:
Street:
Lot 20
Sunset Blvd
Builder Name: PSL Prop
Permit Office:
Rotate Angle: 0
No
County:
City, State, Zip:
St. Lucie
Fort Pierce, FL
34982
Jurisdiction: St. Lucie
Family Type: Single -Family
Plans)
Cross Ventilation:
Whole House Fan: No
erin:can/Lake
Terrain:
w
New/Existing: Ne(From
Year Construct:Shielding:
uburban
Comment:
CLIMATE
IECC Design Temp Int Design Temp
Heating
Design
Daily Temp
J Design Location
TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days
Moisture
Range
FL, St Lucie Co Intl
FL -Fort -Pierce 2 41 90
70 75
486
57
Low
BLOCKS
# Name
Area Volume
1 House
1601.75 ft2 13784.20 ft'
SPACES
# Area
Volume Kitchen Occupants Bedrooms Infil ID Finished
Cooled
Heated
1 M Hall 26.00 ft2
208.00 ft' No 0
0
0 1
0 1
Yes
Yes
Yes
Yes
Yes
Yes
2 Laundry 68.25 ft2
3 Master Bath 90.00 ft2
546.00 ft' No
720.00 ft' No 0
0 1
1
Yes
Yes
Yes
Yes
Yes
Yes
4 WIC 63.25 ft2
5 Master Bed 246.50 ft2
506.00 ft' No 0
2095.25 ft' No 0
0
1 1
1
Yes
Yes
Yes
Yes
Yes
Yes
6 Pantry 15.00 ft2
7 Kitchen/Nook 274.50 ft
120.00 ft3 No 0
2552.85 ft Yes 2
0
0 1
1
Yes
Yes
Yes
Yes
Yes
Yes
8 Great Room 377.00 ft2
9 Bed 3 172.50 ft2
3506.10 ft' No 2
1380.00 ft' No 0
0
1 1
Yes
Yes
Yes
Yes
Yes
Yes
10 Hall 29.75 ft2
11 Lin 7.50 ft2
238.00 ft' No 0
60.00 ft' No 0
0 1
0 1
1
Yes
Yes
Yes
Yes
Yes
Yes
12 Bath 49.50 ft2
13 Bed 2 182.00 ft2
396.00 ft' No 0
1456.00 ft' No 0
0
1 1
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1602 sq.ft.)
# Floor TVpe
Space Perimeter R-Value Area
U-Factor
Tile Wood Carpet
1 On Grade Depth, Tile Fir Fnsh
M Hall 4
Laundry 11
ft 0 26.00 ft2
ft 0 68.25 ft2
0.989
0.989
1.0
1.0
0 0
0 0
2 On Grade Depth, Tile Fir Fnsh
3 On Grade Depth, Tile Fir Fnsh
Master Bath 22
ft 0 90.00 ft
63.25 ft2
0.989
0.989
1.0
1.0
0 0
0 0
4 On Grade Depth, Tile Fir Fnsh
5 On Grade Depth, Tile Fir Fnsh
WIC 17
Master Bed 15
ft 0
ft 0 246.50 ft2
0.989
1.0
1.0
0 0
0 0
6 On Grade Depth, Tile Fir Fnsh
7 On Grade Depth, Tile Fir Fnsh
Pantry 0
Kitchen/Nook 24
ft 0 15.00 ft2
ft 0 274.50 ft
0.989
0.989
0.989
1.0
1.0
0 0
0 0
8 On Grade Depth, Tile Fir Fnsh
Great Room 29
Bed 3 27
ft 0 377.00 ft2
ft 0 172.50 ft2
0.989
1.0
0 0
9 On Grade Depth, Tile Fir Fnsh
10 On Grade Depth, Tile Fir Fnsh
Hall 0
ft 0 29.75 ft2
7.50 ft2
0.989
0.989
1.0
1.0
0 0
0 0
11 On Grade Depth, Tile Fir Fnsh
Lin 0
Bath 6
ft 0
ft 0 49.50 ft2
0.989
1.0
0 0
12 On Grade Depth, Tile Fir Fnsh
13 On Grade Depth, Tile Fir Fnsh
Bed 2 36
ft 0 182.00 ft2
0.989
1.0
0 0
ROOF
Roof Gable
Roof Solar SA
Emitt
Emitt
Deck Pitch
# Type Materials Area Area
Color Absor. Tested
Tested
Insul. (deg)
1 Hip RoofAsph 1791 f?
470 ft2
Medium 0.75 No
Medium 0.75 No
0.90
0.90
No
No
0 27
0 27
2 Hip RoofAsph
ATTIC
4, # Type
Ventilation Vent Ratio 1 in)
Area RBS
IRCC
1 Full attic
Full attic
Vented 150
Vented 150
1601.75ft2 N
420.25 ft2 N
N
N
2
2020-Dec-29 15:09:13
wright,Oft" Right -Suite® Universal 2021 21.0.02 RSU29066 Right -Energy® Florida2017 Section 405.4.1 Compliant Software Page
��fff h1j,,^A, ' Wnghtsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R4Ub-11L)'I l
CEILING
(Total Exposed Area = 1602 sq.ft.)
4' #
Ceiling Type
Space
R-Value U-Factor
Area
Framing Fraction Truss Type
1
Attic, Shngls, R-30 Roof Ins, 1/2" G
M Hall
30 0.034
0.034
26.00 ft2
68.25 ft2
0.10 Wood
0.10 Wood
2
3
Attic, Shngls, R-30 Roof Ins, 1/2" G
Attic, Shngls, R-30 Roof Ins, 1/2" G
Laundry
Master Bath
30
30 0.034
90.00 ft
0.10 Wood
Wood
4
5
Attic, Shngls, R-30 Roof Ins, 1/2" G
Attic, Shngls, R-30 Roof Ins, 1/2" G
WIC
Master Bed
30 0.034
30 0.034
63.25 ft2
246.50 ft2
0.10
0.10 Woad
Wood
6
Attic, Shngls, R-30 Roof Ins, 1/2" G
Pantry
30 0.034
0.034
15.00 ft2
274.50 ft
0.10
0.10 Wood
7
Attic, Shngls, R-30 Roof Ins, 1/2" G
Kitchen/Nook
30
30 0.034
377.00 ft2
0.10 Wood
8
9
Attic, Shngls, R-30 Roof Ins, 1/2" G
Attic, Shngls, R-30 Roof Ins, 1/2" G
Great Room
Bed 3
30 0.034
129.75 ft2
0.10 Wood
0.10 Wood
10
Attic, Shngls, R-30 Roof Ins, 1/2" G
Hall
30 0.034
0.034
29.75 ft2
7.50 ft2
0.10 Wood
11
12
Attic, Shngls, R-30 Roof Ins, 1/2" G
Attic, Shngls, R-30 Roof Ins, 1/2" G
Lin
Bath
30
30 0.034
49.50 ft2
0.10 Wood
Wood
13
Attic, Shngls, R-30 Roof Ins, 1/2" G
Bed 2
30 0.034
182.00 ft2
0.10
WALLS
(Total Exposed Area = 1580 sq.ft.)
Adjacent
Cavity Width Height
Sheathing
U Frm. Solar Below
4" # Wall Type
Space
R-Value Ft In Ft In
Area R-Value
Factor Frac. Absor. Grade%
Ornt
To
1
Partition Frm Wall, 1/2" Gy
M Hall
11 4 0 8 0
0
32.0 ft2 0
84.0 ft2 0
0.101 0.25 0.75 0
0.101 0.25 0.75 0
2
Partition Frm Wall, 1/2" Gy
E Exterior Blk Wall, Stucco
Laundry
Master Bath
11 10 6 8
0 2 0 8 0
16.0 ft 4
0.109 0.22 0.20 0
0
3
4
S Exterior BIk Wall, Stucco
Master Bath
0 12 0 8 0
1 6 8 0
96.0 ft2 4
12.0 ft2 4
0.109 0.22 0.20
0.109 0.22 0.20 0
5
W Exterior Blk Wall, Stucco
Partition Frm Wall, 1/2" Gy
Master Bath
Master Bath
0
11 6 0 8 0
48.0 ft2 0
0.101 0.25 0.75 0
0
6
7
E Exterior Blk Wall, Stucco
WIC
0 5 6 8 0
0
44.0 ft2 4
92.0 ft2 4
0.109 0.22 0.20
0.109 0.22 0.20 0
8
9
S Exterior Blk Wall, Stucco
E Exterior Blk Wall, Stucco
WIC
Master Bed
0 11 6 8
0 14 6 8 6
123.3 ft2 4
4
0.109 0.22 0.20 0
0.109 0.22 0.20 0
10
E Exterior Blk Wall, Stucco
Kitchen/Nook
0 23 6 9 4
0 26 0 9 4
218.6 . ft2
241.8 ft2 4
0.109 0.22 0.20 0
11
12
W Exterior Blk Wall, Stucco
Partition Frm Wall, 1/2" Gy
Great Room
Great Room
11 3 0 9 4
27.9 ft2 0
0.100.25 0.0
0
13
N Exterior Blk Wall, Stucco
Bed 3
0 12 0 8 0
15 0 8 0
96.0 ft 4
120.0 ft2 4
0.1099 0.22 0.2200
0.109 0.22 0.20 0
14
E Exterior Blk Wall, Stucco
Bed 3
Bath
0
0 5 6 8 0
44.0 ft2 4
0.109 0.22 0.20 0
15
16
N Exterior Blk Wall, Stucco
N Exterior Blk Wall, Stucco
Bed 2
0 16 0 8 0
128.0 ft2 4
0.109 0.22 0.20 0
8 0
100.0 ft2 4
0.109 0.22 0.20 0
18
W Exterior Blk Wall, Stucco
Bed 2
0 12 6
WINDOWS
(Total Exposed Area = 179 sq.ft.)
Wall
Overhang Interior
,1' #
Ornt ID Frame Panes
NFRC
U-Factor SHGC Impact Area Depth
Separation Shade Screening
1
S 4 Metal Low-E Double
Yes
0.580 0.24 Yes
0.580 0.24 Yes
4.5ft2 1 ft 0 in
15.6ft2 1 ft 0 in
1 ft 0 in Blinds 45' outdoor
1 ft 0 in Blinds 45' outdoor
2
3
E 9 Metal Low-E Double
E 10 Metal Low-E Double
Yes
Yes
0.650 0.21 Yes
48.Oft2 10 ft 0 in
22.4ft2 6 ft 0 in
1 ft 0 in None None
1 ft 0 in Blinds 45° outdoor
4
5
W 11 Metal Low-E Double
W 11 Metal Low-E Double
Yes
Yes
0.620 0.22 Yes
0.650 0.24 Yes
48.Oft2 9 ft 1 in
1 ft 0 in None None
1 ft 0 in Blinds 45° outdoor
6
E 14 Metal Low-E Double
15 Metal Low-E Double
Yes
Yes
0.580 0.24 Yes
0.580 0.24 Yes
15.6ft2 1 ft 0 in
9.5ft2 1 ft 0 in
1 ft 0 in Blinds 452 outdoor
7
N
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
0
1
INFILTRATION
#
Scope Method
SLA
CFM 50 ELA
E LA ACH. ACH 50
1
Wholehouse Sim lifted
0.000384
1608 88.46
166.1 0.53 7.00
HEATING SYSTEM
4, #
System Type
Rithtvnp Efficienc
Ca acit
Block Ducts
1
Electric strin
AFUE: 100.0 23.5 kBtu/hr 1 s s#1
COOLING SYSTEM
41 #
S stem TVpe
SubtVpe Efficiency
Capacity Air Flow SHR Block Ducts
1
Split air conditioner
SEER: 15.5 28.0 kBtu/hr 933 cfm 0.70 1 s s#1
HOT WATER SYSTEM
#
System Type Subtype Location EF Cap
Use SetPnt
Conservation
1
Electric conventional
0.96 40 gal
60 gal 120 T
None
+1 aightSQft16 Right -Suite® Universal 2021 21.0.02 RSU29066 Rig ht-Energy® Florida 2017 Section 405.4.1 Compliant Software_ VVV �V '_I;age' 4
;�: a�� ., ...Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
DUCTS
________ Supply --------
4, # Location R-Value Area
---- ---- Return
Location
---------
Area Leakage Type
Air
Handler
CFM 25 Percent
Out Leakage
QN RLF
HVAC #
Heat Cool
1 House Attic 6.0
319 fe
House Attic
18 ft2 Default Leakage
House
(Default)
6.00
1 1
TEMPERATURES
Programmable Thermostat: Y
Ceiling Fans:
Cooling [ X ]Jan
X
[ X] Feb
[ X] Feb
[ X] Mar
[ X] Mar
[ X] Apr
[ X] Apr
[ X]
[ X]
May [ X] Jun
May [ X] Jun
[ X] JUI
[ X] Jul
[X] Aug
[ X] Aug
[X] Sep
[ X] Sep
[ X] Oct [ X] Nov
[ X] Oct [ X] Nov
[ X] Dec
[ X] Dec
Heating [ ]Jan
Venting [ X ]Jan
[ X] Feb
[ X] Mar
[ X] Apr
[ X] May [ X] Jun
[ X] Jul
[ X] Aug
[ X] Sep
[ X] Oct [ X] Nov
[ X] Dec
Thermostat Schedule: Florida
Building Code, 6th Edition
Hours
7
8
9
10 11
12
Schedule Type
2017
1
2
3
4 5
6
Cooling (WD)
AM
75
75
75
75 75
75
75
75
75
75
75
75
75
75 75
75 75
75
75
PM
75
75
75
75 75
Cooling (WEH)
AM
75
75
75
75 75
75
75
75
75
75
75
75
75
75
75 75
75 75
75
75
PM
75
75
75
75
Heating (WD)
AM
72
72
72
72 72
72
72
72
72
72
72
72
72
72 72
72 72
72
72
PM
72
72
72
72 72
Heating (WEH)
AM
72
72
72
72
72
72 72
72 72
72
72
72
72
72
72
72
72
72 72
72 72
72
72
PM
72
2020-Dec-29 15:09:13
° 014Tr7Cght55oftO Right-Suite®Universal2021 21.0.02 RSU29066 Right -Energy@ Florida2017 Section405.4.1 Compliant Software Page
'�-j ...Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Cale = MJ8 Front Door faces: N
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX = 95
The lower the EnergyPerformance Index, the more efficient the home.
1. New home or addition
2. Single-family or multiple -family
3. Number of units, if multiple -family
4. Number of bedrooms
5. Is this a worst case? (yes/no)
6. Conditioned floor area (ftz)
7. Windows, type and area*
a. U-Factor:
b. Solar Heat Gain Coefficient (SHGC):
c. Area (ft2)
8. Skylights
a. U-Factor:
b. Solar Heat Gain Coefficient (SHGC):
9. Floor type, insulation level
a. Slab -on -grade (R-value):
b. Wood, raised (R-value):
c. Concrete, raised (R-value)
10 Wall type and insulation:
a. Exterior:
1. Wood frame (Insulation R-value):
2. Masonry (Insulation R-value):
b. Adjacent:
1. Wood frame (Insulation R-value):
2. Masonry (Insulation R-value):
11. Ceiling type and insulation level
a. Under attic (R-value):
b. Single assembly (R-value):
c. Knee walls/skylight walls (R-value)
d. Radiant barrier installed
1. New (From Plans) 12
2. Single -Family
3. 1
5.
Yes
6.
1601.75
Db7&npact(Avg), 0.626
7b.
0.23
7c.
179
8a.
8b.
9a.
0.0
9b.
9c.
10al.
10a2. 4
10bl. 11
10b2.
11a. 30.0
11 b.
11 C.
11 d.
Ducts, location & insulation level
a. Supply ducts: R 6.0
b. Return ducts: R 6.0
c. AHU location: House
13. Cooling systems
Capacity
28.0
a. Split system:
SEER
15.50
b. Single package:
SEER
c. Ground/water source: SEER/COP
d. Room unit/PTAC:
EER
e. Other:
14. Heating systems
Capacity
23.5
a. Split system heat pump:
HSPF
b. Single package heat pump:
HSPF
c. Electric resistance:
COP
100.00
d. Gas furnace, natural gas:
AFUE
e. Gas furnace, LPG:
AFUE
f. Other:
15. Water heating systems
a. Electric resistance:
EF
0.960
b. Gas fired, natrual gas:
EF
c. Gas fired, LPG:
EF
d. Solar system with tank:
EF
e. Dedicated heat pump with tank: EF
f. Heat recovery unit:
HeatRec%
g. Other:
16. HVAC credits claimed (Performance Method)
a. Ceiling fans:
b. Cross ventilation:
c. Whole house fan:
d. Multizone cooling credit:
e. Multizone heating credit:
f. Programmable thermostat:
Yes
*Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features
which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home: Lot 20 Sunset Blvd
Date:
City/FL Zip: Fort Pierce, FL 34982
2020-Dec-29 15:09:13
WrlghtSOftO RightSuite®Universal2021 21.0.02 RSU29066 Right -Energy® Florida2017 Section405.4.1 Compliant Software Page
Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: Lot 20 Sunset Blvd PERMIT #:
Fort Pierce, FL 34982
MANDATORY REQUIREMENTS - See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies reflects components
andaspecifi ationsllsubmitted o demo st ategned ompliancethe bforlder The tthe builds gl. ing A ccopy oflshall the EPL display ca dthat the EPL an bepfound ncardaccu
Append xratel RDthe plans
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing
methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
w ith the manufacturer's instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third parry shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f) (g), or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond
intended infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeledin accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square 1.5 /11doors no more than 0.5 t lwhen tested abeled o NFRC 400 or
AMA/WDMA/CSA01%IS2/A44and 0by an accredited, independent laboratory and Is listed and by the manufacturer.
Exception: Site -built windows, skylights and doors.
2020-Dec-29 15:09:13
Wright8of' " Right -Suite® U niversal 2021 21.0.02 RSU29066 Right -Energy® Florida 2017 Section 405.4.1 Compliant Software Page 7
Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
MANDATORY REQUIREMENTS -(Continued)
R402.4.4 Rooms containing fuel -burning appliances In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from Inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shalt meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent apliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing (Mandatory). All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air C403 2.9t2 offthe Commerc al shall
Prrovsons of this code and nsidered ducts and shall be shown tenum o meet duct tightness l be rater a below. nd sealed in accordance with Section
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7),
Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g), or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an.air leakage of no more than 2 percent
of the design air flow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building Cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 55°F (13°C) shall be insulated to a minimum of R 3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be In accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
0 R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe
shall be dedicated return pipe or a cold water supply pipe. Gravity and thermoslphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
ElR403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or LIL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
2020-Dec-29 15:09:13
WtightSof#1 Right-Suite®Universal2021 21.0.02 RSU29066 Right -Energy® Flodda2017 Section405.4.1 Compliant Software Page
hy, �.«� �,; ;�t 7 Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
MANDATORY REQUIREMENTS -(Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat
traps installed on both the Inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as
possible to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1 Storage water heater temperature controls.
R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the Intended use. The minimum temperature
setting range shall be from 100°F to 140oF (38°C to 60°C).
ElR403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment
installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the
appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water heating system. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TMA, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
EDR403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida
Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation, including:
Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the
ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by
an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical
ventilation shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved methodologies, heating and cooling calculation
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
unrrcn eeGruAnt1rA1 VFNTII ATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
CFM
MINIMUM EFFICACY (a)
CFM/WATT
AIRFLOWRATEMAXIMUM
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
< 90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm - 28.3 L/min. (a) When tested in accordance HVI Standard 916
2020-Dec-29 15:09:13
- wrigjhtsaftO Right-Suite®Universal2021 21.0.02 RSU29066 Right -Energy® Fiorids2017 Section405.4.1 Compliant Software Page
Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
MANDATORY REQUIREMENTS -(Continued)
rl R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is
less than the calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the
capacity of equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
ElR403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls (Mandatory). Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the systemw hen the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that w ill allow shutoff when the outdoor temperature is above 40°F (4.8°C).
R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
rJR403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operations.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor- retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
ElR403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
2020-Dec-29 15:09:13
wrightsoftO Right-Suite®Universal202121.0.02RSU29066 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page10
cai,a,Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
MANDATORY REQUIREMENTS - (Continued)
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with 1e Standard
lilConditions-Low orreport ttlaboratory is
quiredtoVifYproceduecompliance. Geotrmal swmming pol heat pumps are t required to eethsstandard.
R403.11 Portable spas (Mandatory). The energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
high -efficacy tlamps or not of lesment s (Mandatory).
percent of thethan 75 per permanently installed lighting ercent of the fixs in tures shall permanently
installed n only high efficacy lamfixtures ps.
Exception: Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
2020-Dec-29 15:09:13
wlightsloftO Right -Suite@ U niversal 2021 21.0.02 RSU29066 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page11
ara3�ir�„;...Wrightsoft HVAC\Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Spec Home Builder Name PSL Prop
Street: Lot 20 Sunset Blvd Permit Office:
City, State, Zip: Fort Pierce, FL 34982 Permit Number:
Owner: Sppec Home Jurisdiction: St. Lucie
Design Location: FL, St Lucie Co Intl
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
/
V
General
A continuous air barrier shall be installed in the
building envelope. The exterior thermal envelope
Air -permeable insulation shall not be used as a
❑
requirements
contains a continuous barrier. Breaks or joints in the
sealing material.
air barrier shall be sealed.
Ceilinglaftic
The air barrier in any dropped ceiling/soffit
The insulation in any dropped ceiling/soffit
shall be aligned with the insulation and any
shall be aligned with the air barrier.
❑
gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors
to unconditioned attics paces shall be sealed.
Walls
The junction of the foundation and sill plate
shall be sealed.The junction of the top plate
Cavities with corners and headers of frame walls
shall be insulated by completely filling the cavity
and the top of exterior walls shall be sealed.
with a material having a thermal resistance of R-3
❑
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier
Windows, skylights
The space between window/doorjambs and framing,
and framing shall be sealed.
❑
and doors
and skylights
Rim joists are insulated and include an air
Rim joists shall be insulated.
❑
Rim joists
barrier.
Floors (including
The air barrier shall be installed at any exposed
Floor framing cavity Insulation shall be installed
to maintain permanent contact with the underside
above -garage and
cantilevered floors)
edge of insulation.
of subfloor decking, or floor framing cavity
insulation shall be permitted to be in contact
❑
with the top sideof sheathing, or continuous
insulation installed on the underside of floor
framing and extends from the bottom to the top of
all perimeter floor framing members.
Crawl space
walls
Exposed earth in unvented crawl spaces shall be
covered with a Class I vapor retarder with
Where provided in lieu of floor insulation,
insulation shall be permanently attached
❑
overlapping joints taped.
to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft
❑
openings to exterior or unconditioned space shall
be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or
narrow cavities shall be filled by insulation that
❑
on installation readily conforms to the available
cavity spaces.
Garage
Air sealing shall be provided between the garage
❑
separation
and conditioned spaces.
Recessed
Recessed light fixtures installed in the building
Recessed light fixtures installed in the
❑
lighting
thermal envelope shall be sealed to the drywall.
building thermal envelope shall be airtight
and IC rated.
Plumbing and
Batt insulation shall be cut neatly to fit around
wiring and plumbing in exterior walls, or
wiring
insulation that on installation readily conforms
❑
to available space shall extend behind piping
and wiring.
Shower/tub on
The air barrier shall be installed behind
Exterior walls adjacent to showers and tubs
❑
exterior wall
electrical or communication boxes or air -sealed
shall be insulated.
boxes shall be installed.
Electrical/phone
The air barrier shall be installed behind
❑
box on exterior
electrical or communication boxes or air -sealed
walls
boxes shall be installed.
HVAC register
HVAC register boots that penetrate building
❑
boots
thermal envelope shall be sealed to the subfloor
or drywall.
Concealed
When required to be sealed, concealed fire
sprinklers
sprinklers shall only be sealed in a manner that
by the
❑
is recommended manufacturer.
Caulking or other adhesive sealants shall not be
used to fill voids between fire sprinkler cover
plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC400.
2020-Dec-29 15:09:13
014 rightsoft" Right -Suite® Universal2021 21.0.02 RSU29086 Right -Energy® Florida 2017 Section4054.1 Compliant Software Page 12
Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: St. Lucie
Permit Number:
Job Information
Builder: PSL Prop Community: Lot:
Address: Lot 20 Sunset Blvd Unit:
City: Fort Pierce State: FL Zip: 34982
Air. Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method.
❑ PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
Climate Zones 1 and 2.
7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) In
building or dwelling unit shall be tested and verified as having an air leakage rate of not
PERFORMANCE or ERI METHOD exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or
ElPERFORMANCE
R406-2017 (ERI), section labeled as Infiltration, sub -section ACH50.
ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ERI): K,
x60 _ 13784 = Method for calculating building volume:
CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans
❑ PASS Code software calculated
❑ Field measured and calculated
❑ When ACH(50) is less than 3, Mechanical Ventilation installation
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.
(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals
licensed as set forth in Section 489.105(3)(f), (g), or (i) or and approved third party. A written report of the results of the test shall be
signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
2020-Dec-29 15:09:13
wrightsoft" Right -Suite® Universal 202121.0.02 RSU29066 Right -Energy® Florida 2017 Section 405.4.1 Compliant Software Page13
yura:�s da Wrightsoft HVACXLot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
FORM R405-2017
Duct Leakage Test Report
Residential Perscriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: St. Lucie
Job Information
Permit Number:
Builder: PSL Prop Community: Lot:
Address: Lot 20 Sunset Blvd Unit:
City: Fort Pierce State: FL Zip: 34982
Duct Leakage Test Results
System 1
cfm25
System 2
cfm25
System 3
cfm25
Sum of any
additional systems
cfm25
Total of all
systems
cfm25
1602
Total of all Total Conditioned
systems Square Footage
❑ PASS
Qn
❑ FAIL
❑ Prescriptive Method cfm25 (Total)
To qualify as "substantially leak free" Qn Total must be less
than or equal to 0.04 if air handler unit is installed. If air handler
unit is not installed, Qn Total must be less than or equal to
0.03. This testing method meets the requirements in
accordance with Section R403.3.3.
Is the air handler unit installed ❑ YES ('_ 0.04 Qn)
during testing? ❑ NO (<= 0.03 Qn)
❑ Performance / ERI Method cfm25 (Out or Total)
To qualify using this method, Qn must be not greater than the
proposed duct leakage Qn specified on Form R405-2017 or
R406-2017.
Leakage Type selected on Form Qn specified on Form R405-2017
R405-2017 (Energy Calc) or R406-2017 (Energy Calc) or R406-2017
Default Leakage
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set
forth in Section 489.105(3)(f), (g) or (i), Florida Statues.
Testing Company
Company Name:
Phone:
I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
2020-Dec-29 15:09:13
virrightsof#° Right -Suite® Universal 2021 21.0.02 RSU29066 Right -Energy® Florida 2017 Section405.4.1 Compliant Software Page 14
,;.;. 6_i Wrightsoft HVAC1Lot 20 Sunset Blvd PSL Prop.rup Calc = MJ8 Front Door faces: N
Reference Home Characteristics
Spec Home
Title: Lot 20 Sunset Blvd PSL Prop
Lot 20 Sunset Blvd
Fort Pierce, FL 34982
FLBase2017
Above -grade Walls (Uo)
0.084
• Above -grade Wall Solar Absorptance
0.75
Above -grade Wall Infared Emittance
0.90
Basement Walls (Uo)
n/a
Above -grade Floors (Uo)
n/a
Slab Insulation R-Value
0.0
Ceilings (Uo)
0.030
Roof Solar Absorptance
0.75
Roof Infared Emittance
0.90
Attic Vent Area (ftZ)
5.34
Crawls pace Vent Area (ft2)
n/a
Exposed MasonryFloorArea (ft2)
404.40
Carpet & Pad R-Value
2.0
Door Area (ftz)
0.00
Door U-Factor
n/a
North Window Area (ftz)
0.00
South Window Area (ft2)
44.80
East Window Area (ft2)
44.80
West Window Area (ft2)
44.80
Window U-Factor
0.400
Window SHGC (Heating)
0.2169
Window SHGC (Cooling)
0.2169
ACH50
7.00
Internal Gains * (Btu/day)
68334
Water heater gallons per day
60.00
Water Heater set point temperature
120.00
Water heater efficiency rating
0.95
Labeled Heating System Rating and Efficiency
HSPF = 8.2
Labeled Cooling System Rating and Efficiency
SEER = 14.0
Air Distribution System Efficiency
0.88
Thermostat Type
Manual
Heating Thermostat Settings
72.0 (All hours)
TMY City: FL —Fort —Pierce
L
2
4l7
IMPORTANT
A 10.0 PSF
—NIT WITH
. PSF
" PSF,
PSF
BCDL' 10 PSF BCDL: PSF
TOTAL' 37 PSF TOTAL PSF
DURATION: 1.2 DURATION:
CAUTIONM
1T ATTEMPT TO ERECT
S WRHOUT REFERRING TO
GINEEONG DRAWINGS AND
SUMMARY SHEETS.
TMANENT BRACING MUST BE
ICE PRIOR TO LOADING
M. Ile. SHEATHING,
ES, ETC.)
1TERIOR BEARING WALLS
RF. IN PLACE PRIOR TO
REEK TO FINAL ENGINEERING
SHEETS FOR THE FOLLO'MNG.
11 NNMBER OF GIRDER PLIES AND
2) BEARING BLOCK REOOIREMENTS,
3) SCAB DETAILS (IF REQUIRED)
d) UPLIFT AND GRAVITY REACTIONS.
WARNING
Backcml— WIINot Be Accepts'
Regardless Fault With out Prim
NouRcaden Byy Customer Wi de
Hours BY And InvesBgation By
B.Hd.0 I.EX Fi KIONSw
NO E%CEPTIONS.
iM1e General C-Irsctor Is Responsible
For All Connections 0-, TM1an Truss
m Truss, Gable Shear Wall, And
Connections. Temporary and
Pemunent B—I'l And CeTng And
Roe( Diaphragm Connactions.
PORT SAINT LUCIE PROP
RES: N!A
MODEL SUNSET KEY
m
REVISIONS:
1.
2.
3.
6
ved And
Neal
Prlor To Ve
TES ALL 1, FirstSouice
RAVE
701 S. HINGS HIGMNAY
FORT PIECE. FL 3 S
Ph.(TT21•d61 54TS
* wrightsoft°
Load Short.i=orm
House
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 EMail:Vlc4lym@aircalcs.com
For: Spec Home, Air Conditioning Unlimited
Lot 20 Sunset Blvd, Fort Pierce, FL 34982
Job: 1402
Date: Dec 29, 2020
By. Chris Bateman
Htg
Clg
Infiltration
Outside db (°F)
41
90
Method
Simplified
Average
Inside db (OF)
70
75
Construction quality
Design TD (°F)
29
15
Fireplaces
Daily range
-
L
Inside humidity (%)
30
50
Moisture difference (gr/Ib)
2
57
HEATING EQUIPMENT
COOLING EQUIPMENT
Make
Make Goodman Mfg.
Trade
Trade GOODMAN
Model
Cond GSX16S301A
AHRI ref
Coil ASPT39C14A
AHRI ref 201785799
Efficiency
100 EFF
Efficiency 13.0 EER,15.5 SEER
19600
Btuh
Heating input
6.9
23456
kW
Btuh
Sensible cooling
Latentcooling
8400
Btuh
Heat ngoutput
Temperature rise
23
OF
Total cooling
28000
Btuh
Actual airflow
933
0.042
cfm
cfm/Btuh
Actual airflow
Air flow factor
933
0.046
cfm
cfm/Btuh
Air flow factor
Static pressure
0.70
in H2O
Static pressure
0.70
in H2O
Space thermostat
Load sensible heat ratio
0.78
ROOM NAME
82
Area
(ft)
Httg�load
(Btuh)
CIIg load
(tgAVF
�)VF
M Hall
26
68
0
895
0
1000
0
38
0
46
Laundry
Master Bath
90
1965
772
83
35
WIC
63
247
1589
1986
594
2290
67
84
27
105
Master Bed
0
0
0
0
Pantry
Kitchen/Nook
15
275
3594
4809
152
220
Great Room
377
4730
6028
200
123
276
96
Bed 3
173
2897
2100
0
0
Hall
30
0
0
0
0
0
0
Lin
Bath
8
50
728
398
31
18
3687
9422
156
111
Bed 2
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
2020-Dea29 15:11:28
-!}i- wrightsoft® Page 1
RightSute®Universal 202121.0.02RSU29066
/�+�...w6ghlsoftHVAQLot20Sunset Blvd PSLPropxup Caic=MJ8 FrontDoorfaces: N
House
Other equip loads
Equip. @ 0.95
Latent cooling
TOTALS
1602 22071 20414 933 933
1467 779
RSM 20218
5922
1602 23537 26140 933 933
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
2020-Dec-29 15:11:28
ti wrightsoft® Page 2
29066
Right-Stite®Udversal202121.0.02RSU
�=...WrightsoftHVACtL.ot20SusetBlvd PSLProp x1p Calc=MJ8 Frort Door faces'. N
Job: 1402
-�- Building Analysis Date: Dec 29,2020
wrightsoft"
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock LR Vero Beach, FL32966 Phone:772.800.8413 Email: vicldlynne@airmlcs.com
For: Spec Home, Air Conditioning Unlimited
Lot 20 Sunset Blvd, Fort Pierce, FL 34982
on:
Location:
Indoor:
Indoor temperature (°F)
Heating
Cooling
St Co Intl, FL US ,
Elevation: ft
Design TD (°F)
29
30
15
50
Latitude: 28°N
Outdoor: Heating
Cooling
Relative humidity (%)
Moisture difference (grAb)
2.4
56.9
Dry bulb (°F) 41
Dail range °F -
90
15 ( L )
Infiltration:
Method
Simplified
Wet bulb (°F)) -
77
Construction quality
Average
0
Wind speed (mph) 15.0
7.5
Fireplaces
Component
Btuhfft2
Btuh
% of load
Walls
3.1
4371
18.6
Glazing
18.2
3253
13.8
Doors
Ceilings
0
1.0
0
1588
0
6.7
Floors
3.4
5392
22.9
Infiltration
2.0
2782
11.8
Ducts
4684
19.9
Piping
0
0
Humidification
0
0
Ventilation
14677
6.2
Adjustments
Total
23537
100.0
Component
Btuh/ftZ
Btuh
%of load
Walls
1.9
2715
12.8
Glazing
20.6
3700
17.5
Doors
0
0
0
Ceilings
1.8
2891
13.6
Floors
0
0
0
Infiltration
0.6
778
3.7
Ducts
5311
25.1
Ventilation
779
3.7
Internal gains
5020
23.7
Blower
0
0
Adjustments
0
Total
211931
100.0
Latent Cooling Load = 5922 Btuh
Overall U-value = 0.105 Btuh/ft2 °F
Data entries checked.
Infiltration
Gains
2020-Dec-29 15:11:28
411- wrightsoft" Page 1
A=- �,..�.•+gym-> Right -sate® Universal 202121.0.02 RSU29066
+M...WrightsoftHVAQLot20ScrsetBlvd PSLProp.rp Calc=MJ8 Front Door faces: N
Job: 1402
-I'�- Component Constructions Date: Dec 29, 2020
wrightsoft®
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vicldlynne@aircalcs.com
For: Spec Home, Air Conditioning Unlimited
Lot 20 Sunset Blvd, Fort Pierce, FL 34982
Indoor:
Heating
Cooling
Location:
St Lucie Co Intl, FL, US
Indoor temperature (OF)
70
75
15
Elevation: 26 ft
Design TD (OF)
Relative humidity (%)
29
30
50
Latitude: 280N
Outdoor: Heating Cooling
Moisture difference (grAb)
2.4
56.9
Dry bulb (OF) 41 90
15 (L
Infiltration:
) Method
Simplified
Daily range (OF) -
Wet bulb (OF) - 77
Construction quality
Average
Wind speed (mph) 15.0 7.5
Fireplaces
0
Construction descriptions
Or Area U value Insul R
ft' Btuh/Wl' ftk*F/Btuh
Htg HTM
Btuh/ft'
Loss Clg HTM Gain
Btuh Btuh/ft' Btuh
Walls
Blk Wall, Stucco Ext, R-4.1 Ext Bd inl, 8" Thk, 1/2" Gyp Bd Int Fnsh
n 259 0.109 5.1
3.15
3.15
814 2.02 521
1395 2.02 892
e 443 0.109 5.1
s 239 0.109 5.1
3.15
755 2.02 483
w 268 0.109 5.1
3.15
844 2.02 540
all 1208 0.109 5.1
3.15
3807 2.02 2435
Partitions
Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16"
192 0.101 11.0
2.94
564 1.46 280
OC Stud
Windows
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24);
n 10 0.580 0
16.8
160 11.5 109
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1 ft overhang (3.17 ft window ht, 1 ft sep.); 8 ft head ht
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24);
a 31 0.580 0
16.8
525 28.1 878
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1 ft overhang (5.2 ft wndow ht, 1 ft sep.); 8 ft head ht
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.21);
a 48 0.650 0
18.8
905 13.1 627
foreground = green grass (0.23); 10 ft overhang (8 ft window ht, 1 ft sep.);
8 ft head ht
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24);
s 5 0.580 0
16.8
76 13.5 61
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
(0.23); 1 ft overhang (2.08 ft window ht, 1 ft sep.); 8 ft head ht
grass
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.22);
w 22 0.620 0
18.0
403 16.8 377
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 6 ft overhang (5.17 ft window ht, 1 ft sep.); 8 ft head ht
Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.22);
w 16 0.620 0
18.0
280 27.2 424
Impact,
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 8 ft head ht
411- wrightsoft®
Universal 2021 21.0.02 RSU29066
2020.-Deo-2915:11:28
Page 1
RightSute®
AC.I�P� WrightsoftHVAC\Lot20SLmetBlvdPSLProp.np Calc=MJ8 FrortDoorfaces: N
Impact, Clear Lowe: Impact, Clear Lowe; NFRC rated (SHGC=0.24); w
foreground = green grass (0.23); 9.1 ft overhang (8 ft window ht, 1 ft sep.);
8 ft head ht
11
Doors
(none)
Ceilings
Attic, Shngis, R-30 Roof Ins, 1/2" Gyp Bd Int Fnsh
Floors
On Grade Depth, Tile Fir Fnsh
48 0.650 0 18.8 905 14.8 711
1602
0.034
30.0
0.99
1588
1.80
2891
188
0.989
0
28.7
5392
0
0
2020-Deo-29 15:11:28
wrightsoft® Page 2
�, RightStite®Universal 2021 21.0.02 RSU29066 g
��...WrighlsoftWAQLot20SirsetBlvd PSLProp.np Calc=MJB Front Door faces: N
Job: 1402
-l�- Project Summary Date: Dec 29, 2020
Wrightsoft®
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln. Vero Beach, FL32966 Phone: 772.800.8413 Email: vick llYnre@aircZl s.com
limited
For: LSpec ot 20 Sunsett Blvd, Fort Piee Air rce, nFL 34982
Notes:
Weather: St Lucie Co Inti, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
41 F
70 °
Outside db
Inside db
90 OF
75 OF
°F
Inside db
Desi n TD
g
°F
29 F
Design TD
15
L
Daily range
Relative humidity
o
50 /o
Moisture difference
57 gr/lb
Sensible Cooling Equipment Load Sizing
Heating Summary
Structure
17386 Btuh
Structure
Ducts
15103 Btuh
5311 Btuh
Ducts
Central vent (46 cfm)
4684 Btuh
1467 Btuh
Central vent (46 cfm)
779 Btuh
Outside air
0 Btuh
Outside air
Blower
0 Btuh
Humidification
0 Btuh
Piping
Equipment load
23537 Btuh
Use manufacturers data
Rate/swingg multipplier
n
0.95
Equipmentseri le load
20218 Btuh
Infiltration
Simplified
Latent Cooling Equipment Load Sizing
Method
Construction quality
Average
Structure
2576 Btuh
Fireplaces
Ducts
1568 Btuh
1778 Btuh
Central vent (46 cfm)
Heating Coolingg
1602 1602
Outside air
Equipment latent load
5922 Btuh
Area (ft2)
Volume (f13)
13784 13784Btuh
0.38 0.20
Equipment Total Load (Sen+Lat)
26144
Air changes/hour
/houcfm)
87 46
Req. total capacity at 0.70 SHR
ton
2.4 ton
Equiv. AVF
Heating Equipment Summary
Cooling Equipment Summary
Make Goodman Mfg.
Make
Trade GOODMAN
Trade
Cond GSX16S301A
Model
Coil ASPT39C14A
AHRI ref
AHRI ref 201785799
Efficiency
100 EFF
Efficiency 13.0 EER,15.5SEER
Sensible cooling
19600 Btuh
Heating input
Heatingoutput
6.9 kW
23456 Btuh
Latent cooling
8400 Btuh
28000 Btuh
Temperature rise
23 OF
933 cfm
Total cooling
Actual airflow
933 cfrn
Actual airflow
Airflowfactor
0.042 cfm/Btuh
Airflowfactor
0.046 cfm/Btuh
0.70 in H2O
Static pressure
0.70 in H2O
Static pressure
Load sensible heat ratio
0 78
Space thermostat
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
2020-Dec-29 15:11:28
wrfightsoTt®
C Rlght-Stite®Universal 202121.0.02RSU29066Page 1
AOM ...WrightsoftHVAQW20SuisetBlvd PSLProprup Calc=MJ8 FrontDoorfaces: N
Job: 1402
-l�I- wrightsoft° Rlght-J®W®rksheet
Date: Dec 29, 2020
House
By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800,8413 Email: vicldlynne@aircalcs.com
House
M Hall
1 Room name
188.0 ft
4.0 ft
2 F)posed wall
8.6 ft
8.0 ft heat/cool
3 Room height
4.0 x 6.5 ft
4 Room dimensions
1601.8 T
26.0 ft2
5 Room area
r (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Ty Construction U-vaBtjh 3- Or Btu�z)
number (Btuh� -°� (
ooreaperimet
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
Heat Cool
268
10
259
0
814
160
521
109
0
0
0
0
0
0
0
0
6 yJ Blk Wall, Stu000 End 0.109 n 3.15 2.62
11.48
L-G Impact, ClearLow-e 0.580 n 16.82
0.109 a 3.15 2.02
522
443
1395
892
0
0
0
0
Blk Wall, Stump Ext
0.580 a 16.82 28.13
31
0
525
878
0
0
0
0
Impad, Clear Lowe
Impad, Clear Lowe 0.650 a 18.85 13.06
48
44
905
627
0
0
0
0
0
0
yI Elk Wail, Stucco Fed 0.109 s 3.15 2.02
244
5
239
5
755
76
483
61
0
0
0
0
G� Impad,ClearLowe 0.580 s 16.82 13.48
0.109 w 3.15 2.02
354
268
844
540
0
0
0
00
Blk Wall, Stucco F)d
0.620 w 17.98 16.83
22
17
403
377
0
0
0
0
0
Impad, Clear Lowe 0.620 w 17.98 27.18
T�Impad,ClearLowe
16
0
280
424
711
0
0
0
0
0
0
�i ImpadCiearLowe 0.650 w 18.85 14.81
2.94 1.46
4.8
192
39
192
905
564
280
32
32
94
47
P Frm Wall,112" Gyp B 0.101
0.034 0.99 1.80
1602
1602
1588
2891
26
26
26
47
0
C Attiq Shngls, R-30
F On Grade Depth, Tile 0.989 28.68 0.00
1602
188
5392
0
26
4
115
6
AED excursion
514
-5
c)
14604
9306
235
89
Envelope loss(gain
2782
778
0
0
12
a) Infiltration
b) Room ventilation
0
0
0
0
Internal gains: Occupants @ 230
4
920
4100
0
0
0
13
Applianceslother
17386
15103T'.,
235
89
Subtotal (lines 6 to 13)
0
00
0
Less extemal load
0
00
0
Lessiransfer
0
0235
-89
Redistribution
17386
151030
0
14
15
Subtotal
Dud loads
27%
35%
4684
5311
27%0
0
22071
20414
0
0
0
Total room load
Air required (dm)
933
933
1
0
Calculations approved b ACCAto meet all requirements of Manual J 8th Ed.
2020-Dec29 15:11:28
-I�i- wrtghtsoft'° �P. RightStiteOUruversa1202121.0.02RSU29066Page 1
Calc=MJ8 Front Door faces: N
...WrightsoftHVAClLot20SusetBlvdPSLProprg7
Job: 1402
-I�d- wrightsofty Right-J®Worksheet Date: Dec29, 2020
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vera Beach, FL32966 Phone: 772.800.8413 Email:vicldlynne@aircalcs.com
Laundry Master Bath
1 Room name 10.5 ft 21.5 ft
2 Exposed wall 8.0 ft heaticool 8.0 ft heaVocol
3 Room height 10.5 x 6.5 ft 7.5 x 12.0 ft
4 Room dimensions 683 ft' 90.0 ftz
5 Room
area
U-value
°F)
Or
HTM
Area (1112)
(ft)
Load
(Btuh)
Area (ft)
or perimeter (ft)
Load
(Btuh)
Ty
Construction
number
(Bllih/ft?
(Btuh/ft-)
or perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
0.109
n
3.15
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
6
y/
BIk Wall, Stucco Ext
L-C'
ImpactClea�Low-e
0.580
n
16.82
11.48
0
0
0
0
16
16
50
32
Val
Blk Wall, Stucco Ext
0.109
e
3.15
2.02
0
0
0
0
0
0
0
0
I-�
Clear Lowe
0.580
a
16.82
28.13
0
0
0
0
0
0
0
0
11
L-G
impact, Clear Lowe
impact,
0.650
a
18.85
13.06
0
0
0
96
91
288
1
y/
L
BIk Wall, Stucco Ext
Impact, Clear Lowe
0.109
0.580
s
s
3.16
16.82
2.02
13.48
0
0
0
0
0
0
5
12
5
12
76
30
61
61
20
-_G
BIk Wall, Stucco Ext
0.109
w
3.15
2.02
0
0
0
0
0
0
0
0
0
Impad,Clear Lowe
0.620
w
17.98
16.83
0
0
0
0
0
0
0
0
Impad, Clear Lowe
0.620
w
17.98
27.18
0
0
0
0
0
0
0
0
Impact, Clear Lowe
Fnn Wall,lf2" Gyp B
0.650
0.101
w
18.85
2.94
14.81
1.46
84
84
247
123
48
90
48
90
141
89
70
16
P
C
Attic, Shngls, R-30
0.034
0.99
1.80
68
68
68
11
fib
301
123
0
90
22
617
0
F
On Grade Depth, Tile
0.989
28.68
0.00
6
AED excursion
-40
-32
c)
616
206
1299
502
Envelope loss/gain
0
0
249
69
12
a) Infiltration
b) Room ventilation
0
0
0
0
Internal gains: Occupants @ 230
0
500
0
0
0
13
Applianceslother
616
706
1548
571
Subtotal (lines 6 to 13)
0
0
Less extemalload
0
p
0
0
Less transfer
90
34
0
0
Redistribution
705
740
1548
571
14
15
Subtotal
Dudloads
27%
35%
190
260
27%
350
417
201
1983 772
35
Total room load 83g 1046 83 35
Air required (cim)
Calculations approved IDACCAto meet all requirements of Manual J 8th Ed.
2020-Deo-2915:11:28
-1+1- wrlightsoft^' Rig ht-StiteOUruversa12021 21.0.02 RSU29066Page 2
N
...WrightsoftHVAQLot20SutisetBlvdPSLProp.rip Calc=MA Front Door faces:
Job:
1402
-�-
wrightsoft°
Right-.1® WorkSheet
Date:
Dec 29, 2020
House
By.
Chris
Bateman
Air Calcs, LLC
7550 Hidden
Hammock Ln, Vero Beach, FL32966
Phone:772.800.8413 Email: vicldlyrm@aircalcs.com
WIC
Nester Bed
1
2
Room name
Exposed wall
8.0 ft
170
ft
heat/cool
8.5 ft
14.5
ft
heaV000l
3
Room height
5.5
x
11.5 It
14.5 x
17.0 ft
4
Room dimensions
63.3 ft'
246.5 ft 2
5
Room area
Ty
Or (Btuh�2)
orperimeter(ft)
Load
(BWh)
Area
or
(ft)
perimeter
(ft)
Load
(Btuh)
number
(Btuh�z°F)
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
Heat Cool
yJ BIk Wall, Stucco Ext
0.109 n 3.15 2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
6
L-G Impact, Clear Lowe
0.580 n 16.82 11A8
0.109 a 3.15 2.02
44
44
139
80
123
100
439
V� BIk Wall, Swoon Ext
0.580 a 16.82 28.13
0
0
0
262
0
0
11
F-G Impact Clear Lowe
_G Impact, Clear Lowe
0.650 a 18.85 13.06
0
0
0
2900
0
180
0
0
y/ BIk Wall, Stucco E)d
0.109 s 3.15 2.02
16.82 13.48
92
0
92
0
0
0
0
0
L--G Impact,Clearl-owe
VV��11 Blk Wall, Stucco E:d
0.580 s
0.109 w 3.15 2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
Impact Clear Lowe
0.620 w 17.98 16.83
17.98 27.18
0
0
0
0
0
0
0
0
0
0
0
Impact, ClearLO%"
0.620 w
0.650 w 18.85 14.81
0
0
0
0
0
0
0
0
0
0
Impact Clear Lowe
P Frm Wall,1)Z' Gyp B
0.101 2.94 1.46
0
0
63
0
63
0
114
0
247
0
247
244
445
C Attic, Shngis, R-30
0.034 0.99 1.80
28.68 0.00
63
63
17
488
0
247
15
416
0
F On Grade Depth, Tile
0.989
-25
4
6 c) AED excursion
979
364
1262
11!69
Envelope loss/gain
273
76
247
12 a) Infiltration
0
0
0
b) Room ventilation
13 Internal gains:
Occupants@ 230
0
0
0
0
0
500
Appliancestother
1251
440
1509
1673
Subtotal (lines 6 to 13)
0
0
0
0
Less external load
0
0
0
0
Lesstransfer
55
21
Redistribution
1251
440
1564
1694
14 Subtotal
27%
35°/u 337
155
270
35% 421
596
15 Ducloads
Total room load
1589
67
594
27
1986
84
2290
105
Air required (dm)
Calculations approved b ACCAto meet all requirements of Manual J 8th Ed.
2020-Deo•2915:11:28
-!}i- wrYghtsoft•
• v '- Right-Stite®Universal 2021 21.0.02 RSU29066
Page 3
Calc=MJB Front Door faces: N
..WrightsoftHVAC1Lot20Su1setBlvdPSLProp.rup
-I�I- wrightsoft9 Right-M Worksheet
House
Job: 1402
Date: Dec 29, 2020
By. Chris Bateman
Air Calcs, LLC
c! nnnaa oi,—:77� 800 8411 FmA1, %. rldlvnne0)aircals.00m
'aournouennaiuniunuy�o�.,�o..,�
.....................—'----. _ _ -
Pantry
Ntchen/Nook
1
Room name
0 It
23.5 It
2
Exposed wall
8.0 ft heat/cool
9.3 ft heaUmol
3
Room height
5.0 x 3.0 ft
1.0 x 274.5 ft
4
Room dimensions
15.0 ft 274.5
ft=
5
Room area
Ty
Construction
U-value
Or
HTM
Area (ft2)
(ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(B1uh)
number
(Btuh/ft2-°F)
(Btuh/ft2)
or perimeter
Cool
Gross
NIPS
Heat
Cool
Gross
N/P/S
Heat
Cool
6 V?/
Blk Wall, Stu000 Ext
0.109
n
2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
L __G
Impact Clear Lowe
0.580
n
11 A8
0
0
0
0
0
219
171
537
344
U�V
Blk Wall, Stucco Ext
0.109
a
2.02
28.13
0
0
0
0
0
00
0
I—�
Impact, Clear Lowe
impact
0.580
a
F16
0
0
0
0
48
44
905
627
1
L—G
ClearLow-e
0.650
a
13.06
0
0
0
0
0
0
�/�JBlk
Wall, Stump EA
0.109
s
2.02
0
0
0
0
0
00
0
L--G
Impact, ClearLow-e
0.580
s
13.48
00
0
0
0
0
0
0
0
W�i
Blk Wall, Stuom Ext
0.109
w
2.02
0
0
0
0
0
0
0
0
Impact, Clear Low-e
0.620
w8
16.83
0
0
0
0
0
0
0
0
Impact, ClearLow-e
0.620
w8
27.18
0
0
0
0
0
0
0
Impact ClearLow-e
0.650
w5
14.81
0
0
0
0
0
0
0
0
0
P.
Frm Wall, IW Gyp B
0.101
-
2.94
0.99
1.46
1.80
0
15
15
15
27
275
275
272
495
C
Attic, Shngis, R-30
0.034
-
0
0
0
275
24
674
0
F
On Grade Depth, Tile
0.989
-
28.68
0.00
15
1
-199
6
c) AED excursion
15
26
2388
1267
Envelope loss/gain
0
0
438
12
12
a) Infiltration
0
0
0
0
0
b) Room ventilation
Internal gains: Occupants @ 230
0
0
0
2
4fi0
1700
13
Applianosslother
15
26
2826
3549
Subtotal (lines 6 to 13)
0
0 0
Less external load
p
0 0
Less transfer
-15
-26
5 9
Redistribution
0 0
2832
3558
14
Subtotal
27%
35%
0 0
27%
350/0
763
1251
15
Duct loads
'
3594 4809
Total room load
p
152 220
Air required (cIm)
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
I�t- wrigF�tsoTt� 2020-Deo-2915:11:28
)'f Right-Sute®Universal 202121.0.02RSU29066 Page
...WrighlsoftHVAQLot20Su1setBlvd PSLProp.nQ Calc=MJ8 Front Door faces: N
Job: 1402
wrightsofta Right-J® Worksheet Date: Dec 29, 2020
House By. Chris Bateman
Air Calcs, LLC
7650 Hidden Hammock Ln Vero Beach, FL32966 Phone: 772.800,8413 Email: vickilynne@aircalcs.com
Great Room
Bed 3
1
Room name
29.0 ft
27.0 ft
2
Exposed wall
9.3 ft heaUcool
8.0 ft heaU000l
3
Room height
26.0 x 14.5 ft
1.0 x 1725 ft
4
Room dimensions
377.0 tt'
172.5
5
Room area
Ty
Construction
U-value
°F)
Or
HTM
Area (T)
(ft)
Load
(Btuh)
2)
Area (ft')
or perimeter (ft)
Load
(Btuh)
number
(BtuhAF
(Btuh/ftz)
or perimeter
Heat
. Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
V1J
Blk Wall, Stucco F)d
0.109
n
3.15
2.02
0
0
0
0
0
0
96
0
96
0
302
0
193
0
L--G
Impact, Clear Lowe
0,580
n
16.82
11 A8
0
0
0
0
0
0
120
104
329
210
VL
Blk Wall, Slu000 Ext
0.109
a
3.15
2.02
0
0
0
16
0
262
439
�mpact,
Clear Lowe
0.580
a
16.8285
28.13
0
0
0
0
0
0
0
0
i mpact Clear Low-e
0.650
a
18.
13.06
0
0
0
0
0
0
0
-G
yJ
Blk Wall, Stucco E)d
0.109
s
3.15
2.02
0
0
0
0
0
0
0
0
0
0
L-G
Impaa Clear WALe
0.580
0.109
s
w
16.82
3.15
13.48
2.02
242
171
540
345
0
0
0
0
Vh
Blk Wall, Stucco Ext
0.620
17.98
16.83
22
17
403
377
0
0
0
0
Impact, Clear Low-e
Impact, Clear Lowe
0.620
w
w
17.98
27.18
0
0
0
0
0
0
0
0
0
0
0
Impact Clear Lowe
0.650
w
18.85
14.81
48
28
39
28
905
82
711
41
0
0
0
0
0
PIFrm
Wall,1/2" Gyp B
0.101
-
2.94
0.99
1.46
1.80
377
377
374
680
173
173
171
311
C
F
Attic, Shngls, R-30
On Grade Depth, Tile
0.034
0.989
-
-
28.68
0.00
377
29
832
0
173
27
774
0
748
11
6
c) AED excursion
3135
2902
1839
1165
Envelope loss/gain
4800
1300
433
121
12
a) Infiltration
0
0
b) Room ventilation
13
Internal gains: Occupants @ 230
2
460
900
0
0
250
Appliancustother
3620
4397
2272
1536
Subtotal (lines 6to 13)
0 0
0
0
Less external load
0
0
Less transfer
106
62
10
17
Redistribution
3726
4460
2282
1554
14
Subtotal
27%
35%
1004
1568
27%
35%
6151
546
15
Dud loads
4730
6028
2523
2196
Total room load
200
276
Air required (dm)
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
tr{.t wrightsoft� 2020-Dec-2915:11:28
Right-Sute®Unversal 2021 21.0.02 RSU29066 Page 5
...WrightsoftHVAC1Lot20Sunset Blvd PSLPropxup Calc=MJ8 Front Door faces: N
Job:
1402
-I+I- wrightsoft'
Right-J® Worksheet
Date:
Dec 29, 2020
House
By.
Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock LR Vero Beach,
FL32966 Phone: 772.800.8413 Email:,AcW]ynne@alrcalcs.com
Hall
Lin
1 Room name
2 E)posed wall
8.0 ItheaUcool
O ft
8.0 Itheatl000l
O ft
3 Room height
3.5
x
8.5 It
2.5 x
3.0 ft
4 Room dimensions
29.8 ft2
7.5 ft2
5 Room area
Ty Conshvclion
U-value Or
Areaperimet (ft)
Load
(Btuh)
Area (ft)
or perimeter
(ft)
Load
(B�h)
number
BHHTMM2)
(Btuh/F oF)
r
Heat Cool
Gross NIPS
Heat Cool
Gross NIPS
Heat Cool
6 \tBlk Wall, Stucco F)d
0.109 n 3.15 2.02
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
L -� Impact ClearLov.e
0.580 n 16.82 11.48
3.15 2.02
0
0
0
0
0
0
0
0
VL1 Blk Wall, Stucco Ext
0.109 a
16.82 28.13
0
0
0
0
0
0
I-{ Impact, Clear Lowe
11 �G ImpaMClearLowe
0.580 a
0.650 a 18.85 13.06
0
0
0
0
0
Q
0
0
0
�/ Blk Wall, Stucco Ext
0.109 s 3.15 2.02
16.82 13A8
0
0
0
0
0
0
0
0
0
0
0
0
L--G Impact, Clear Lowe
Blk Wall, Sturm Ext
0.580 s
0.109 w 3.15 2.02
0
0
0
0
0
0
0
C
0
0
0
J�:Impact, Clear
impact,
0.620 w 17.98 16.83
17.98 27.18
0
0
0
0
0
0
0
0
0
0
G Clear Lowe
0.620 w
0.650 w 18.85 14.81
0
0
0
0
0
0
0
0
0
0
0
Impad,Clear Lowe
P Frm Wall, Gyp B
0.101 2.94 1.46
0
30
0
30
0
29
0
0
8
8
7
14
C Atllc, Shngls, R-30
0.034 0.99 1.80
30
0
0
0
8
0
0
0
F On Grade Depth, Tile
0.989 - 28.68 0.00
_3
1
6 c) AED excursion
7
13
29
51
Envelope losstgain
0
0
0
0
12 a) Infiltration
0
0
0
0
b) Room ventilation
0
13 Internal gains:
Occupants @ 230
0
0
0
0
0
Applianoestother
29
51
7
13
Subtotal (lines 6 to 13)
0
0
0
0
Less external load
0
0
0
0
Less transfer
2g
-51
-7
-13
0
Redistribution
0
0
0
0
14 Subtotal
27%
35%
0
0
27%
35%
0
15 Duct loads
Total room load
0
0
0
0
0
0
0
0
' Air required (dm)
Calculations approved b ACCAto meet all requirements of Manual J 8th Ed.
2020-Dec-29
15:11:28
wrightsoft'
Right-Sute®Universal 202121.0.02RSU29066
Page 6
Sunset Blvd PSLProp.rup Calc=MJB FrontDoorfaces: N
WdghtsoftHVAQLot20
-i}t- wrightsoft, Right-J® Worksheet Job: 1402
House Date: Dec 29, 2020
By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone:772.800.8413 Email:,Addlyye@aircaics.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Bath
5.5 ft
8.0 It heaV000l
9.0 x 5.5 It
49.5 ft=
Bed 2
35.5 ft
8.0 It heat/cool
1.0 x 182.0 ft
182.0 ft'
Ty
Construction
number
U-value
(Btuh/ft? °F)
Or
HTM
(Bbi F)
Area (ft)
or perimeter (ft)
Load
(Btuh)
Area (ftz)
or perimeter (ft)
Load
(Stuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
V�1
�G
Blk Wall, Stucco E)d
Impac , Clear Low-e
Blk Wall, Stu000 Ext
Impact, ClearLow-e
Impact, Clear Lowe
Blk Wall, Sfucoo Ext
Impac,Clear Low-e
Blk Wall, Stucco Ext
Impact Clear Low-e
Impact, Clear Lowe
Impact Clear Lowe
Frm Wall, lf2° Gyp B
Attic, Shngls, R-30
On Grade Depth, Tile
0.109
0.580
0.109
0.580
0.650
0.109
0.580
0.109
0.620
0.620
0.650
0.101
0.034
0.989
n
n
a
a
a
s
s
w
w
w
w
-
-
-
3.15
16.82
3.15
16.82
18.85
3.15
16.82
3.15
17.98
17.98
18.85
2.94
0.99
28.68
2.02
11.48
2.02
28.13
13.06
2.02
13.48
2.02
16.83
27.18
14.81
1.46
1.80
0.00
44
10
0
0
0
0
0
0
0
0
0
0
50
50
35
0
0
0
0
0
0
0
0
0
0
0
50
6
109
160
0
0
0
0
0
0
0
0
0
0
49
168
70
109
0
0
0
0
0
0
0
0
0
0
89
0
128
0
0
0
0
56
0
100
0
16
0
0
182
182
128
0
0
0
0
56
0
84
0
0
0
0
182
36
403
0
0
0
0
176
0
266
0
280
0
0
180
1018
258
0
0
0
0
113
0
170
0
424
0
0
328
0
II�--GGG
yJ
L--G
VV��11
�--G
P
C
F
6
c)AEDexcursion
-16
72
Envelope loss/gain
475
252
2325
1366
12
a) Infiltration
b) Room ventilation
88
0
25
0
569
0
159
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
0
0
0
250
Subtotal (lines 6 to 13)
564
277
2894
1775
14
15
Less extemalload
Lesstransfer
Redistribution
Subtotal
Ductloads
1 27%
35%1
0
0
10
574
155
0
0
17
294
103
27%
35%1
0
0
10
2904
7821
0
0
17
1792
630
Total room load
Air required (clm)
728
31
398
18
3687
156
2422
111
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-rw 2020-Dec-2915:11:28
Rig ht-Sute@Universal 202121.0.02RSU29066 Page
WrightsoftHVAC1Lot20Su1setBlvd PSLProp.rup Calc=MJ8 Front Door faces: N
-I'�- wrightsofte Duct System Summary
House
Air Caics, LLC
7550 Hidden Hammock Ln, Vero Beach, FL32966 Phone: 772.800.8413 Email: vicld"@aircais.com
For: Spec Home, Air Conditioning Unlimited
Lot 20 Sunset Blvd, Fort Pierce, FL 34982
Extemal static pressure
Pressure losses
Available static pressure
Supply return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.70
in H2O
0
in H2O
0.70
in H2O
0.559 / 0.141
in H2O
0.291
in/100ft
933
cfm
240
Job: 1402
Date: Dec 29, 2020
By. Chris Bateman
Cooling
0.70 in H2O
0 in H2O
0.70 in H2O
0.559 / 0.141 in H2O
0.291 in/100ft
933 drn
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bath
h 728
37
22
0.311
4.0
Ox 0
VIFx
44.8
135.0
st3
Bed 2
h 3687
187
133
0.291
7.0
Ox 0
VIFx
51.8
140.0
st3
Bed 3
h 2897
147
115
0.294
7.0
OX 0
VI FX
49.9
140.0
st3
Great Room
c 3014
120
165
0.383
7.0
Ox 0
VIFx
36.0
110.0
st2
Great Room -A
c 3014
120
165
0.381
7.0
OXO
VIFx
36.8
110.0
st2
KitchervNook
c 2404
91
132
0.380
6.0
Ox 0
VIFx
37.0
110.0
st2
KitchenNook-A
C 2404
91
132
0.383
6.0
Ox0
MFx
36.0
110.0
st2
Laundry
c 1000
45
55
0.656
4.0
OX 0
VIFx
5.2
80.0
Master Bath
h 1965
100
42
OA64
5.0
Ox0
VIFx
20.3
100.0
st1
Master Bed
c 1145
50
63
0.475
5.0
OX 0
VI FX
22.6
95.0
st1
MasterBed-A
c 1145
50
63
0.487
5.0
Ox0
VIFx
19.8
95.0
st1
Wic
h 1589
81
33
0.486
5.0
Ox0
VIFx
20.0
95.0
st1
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
Name
st1
st3
st2
PeakAVF
PeakAVF
PeakAVF
281
371
793
201
270
865
0.464
0.291
0.291
805
840
809
8.0
9.0
14.0
0 x 0
0 x 0
0 x 0
VinIFIX
VinIFIX
VinlFlx
st2
�. AWCI jhtSOft® Right-Suite®Universal 2021 21.0.02 RSU29066
...WdghtsoftHVAC1Lot20SusetBlvdPSLProp.nQ Calc=MJB FrontDoorfaces: N
2020-Dec-29 1 b:1129
Page 1
Grille
Htg
Jame
Size (in)
(cfm)
rb5
Ox0
181
rb6
Ox 0
605
rb4
Ox 0
187
rb3
Ox 0
147
TEL
A
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/KF
OpeninMatk
Clg
(Cfm)
158
714
133
115
48.5
0
0
0
0.291
0
0
0
520
0
0
0
80
0
0
0
Ox 0
Ox 0
Ox 0
Ox 0
VIFx
VIFx
Boldldalic values have been manually overridden
2020-Dec-29 15:11:29
wrightsoft® Page 2
ti A—k-(Bslk IIIlV -YAP- Right-Sute®Uriversal2021 21.0.02 RSU29066
.,WrightsoftHVACIot20SusetBlvd PSLProp.ryp Calc=MJ8 FrorADoorfaces: N
Job: 1402
- wrightsoft® Manual S Compliance Report Date: Dec 29, 2020
House By. Chris Bateman
Air Calcs, LLC
7550 Hidden Hammock LR Vero Beach. FL32966 Phone: 772.800.8413 Email: vicldlyme@aircalcs.com
For: Spec Home, AirConditioningUnlimited
Lot 20 Sunset Blvd, Fort Pierce, FL 34982
Design Conditions
Outdoor design DB:
90.4°F
Sensible gain:
21193
Btuh
Outdoor design WB:
77.4°F
Latent gain:
5922
Btuh
Indoor design DB:
75.0°F
Total gain:
27115
Btuh
Indoor RH:
50%
Estimated airflow:
933
clip
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype:
SPIitAC
Manufacturer:
Goodman
Mfg.
Actual airflow:
933
chn
Sensible capacity:
19600
Btuh
Latent capacity:
8400
Btuh
Total capacity:
28000
Btuh
Model: GSX16S301A+ASPT39C14A
92% of load
142% of load
103% of load SHR: 70%
Design Conditions
Outdoor design DB: 41.0°F Heat loss: 23537 Btuh
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: Elecstrip
Manufacturer: Model:
Actual airflow: 933 cfm
Output capacity: 6.9 kW 100% of load
Meets all requirements ofACCA Manual S.
Entering coil DB: 76.9°F
Entering coil WB: 64.1OF
Entering coil DB: 68.0°F
Temp. rise: 50 OF
• 2020-Dec-2915:11:29
` -� wrightsoft® Page 1
�� w�,.�•en.,w..�.n...,�wro RightStite®Uruversa1202121.0.02RSU29066 9
...WrightsoftHVAC1Lot20SusetBlvdPSLProp.rLp Calc=MJ8 Front Door faces: N
C
Level 1
m
��F
-
-
pltx12
---a—
b
—,WOE
e10X0;
b•
r-
:
_
' 1171
r-r,88d3a,
r_
`
11000X�1D
is
a y IUtChanliJ001C
110
do
vfi awm
6•
1
..---- -
x6
33&n �T
6
- '-,
eMastarS dd
Brr'�uri■ciuAc
-
a
5-
S•
'
X.
•6
100 we
®«
1�Xi&•
� PA FIal6
F
P
Great Room �,
k
10z10'
9 fr6'.- :r<u•10 do . ift
El1� 1 do
• _ �s
�' BEDROOM ■1 , • '�' � I
rrPwr�aw i g�SQ ®1\ Ig
■ q 'NIX`Z}'1 IV`
TffIW-
_ _ _ _ _ _ _ _ - � �
1
ff
Pam• --a „ -- .
x52H
Lauri dryer
�"
Master'Bal
.3
-
mxnw
__ _
.9•IN
N.YTx
=
`V •Y as AYP
iNOTE, P+wE•
PYPOPNYLPE
NR.
P1Y�iA0YNCT0 /JIYE PIPE
rage
Ga. .;I
>.. �
]]
n
Job M 1402
Performed by Chris Bateman for:
Spec Home
Lot 20 Sunset Blvd
Fort Pierce, FL34982
Air Calcs, LLC
7550 Hidden Hammock Ln
Vero Beach, FL 32966
Phone: 772.800.8413
vickilynne@aircalcs.com
Scale:1 :136
Page 1
RightSuite® Universal 2021
21.0.02 RSU29066
2020-Dec-29 15:11:43
ALot 20 Sunset Blvd PSL Prop.rup
1. .
N
Job #: 1402
Performed by Chris Bateman for:
Spec Home
Lot 20 Sunset Blvd
Fort Pierce, FL 34982
Level 1
Air Caics, LLC
7550 Hidden Hammock Ln
Vero Beach, FL 32966
Phone: 772.800.8413
vickilynne@aircalcs.com
Scale:1 :126
Page 1
Right Suite® Universal2021
21.0.02 RSU29066
2020-Deo-2915:07:59
\Lot 20 Sunset Blvd PSL Prop.rup