Loading...
HomeMy WebLinkAboutAPPROVED Robert Brazeau Engineering 11-18-21d Wyssling Consulting 76 North Meadowbrook Drive Alpine, UT 84004 Scott E. Wyssling, PE, PP, CME office (201) 874-3483 swyssling@wysslingconsulting.com November 18, 2021 Powur PBC 2683 Via De La Valle Del Mar, CA 92014 Re: Engineering Services Brazeau Residence 60 Mediterranean Blvd E, Port St. Lucie FL 6.380 kW System To Whom It May Concern: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 6 dimensional lumber at 12” on center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Doug-Fir #2 or better with standard construction components. The existing roofing material consists of metal roofing. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used  158 MPH wind loading based on ASCE 7-16 Exposure Category “C” at a slope of 23 degrees  7 PSF = Dead Load roofing/framing Live Load = 20 PSF/ 0 PSF(where panels are installed)  3 PSF = Dead Load solar panels/mounting hardware Total Dead Load =10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the (FBC 2020, 7th Edition). Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. Page 2 of 2 B. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent “Unirac Installation Manual”, which can be found on the Unirac website (http://Unirac.com/). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 lbs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Doug-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 ½”, is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 ½” with a minimum size of 5/16” lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. The solar panels shall be mounted in accordance with the most recent “S-5 Installation Manual”, which can be found on the S-5 website (http://s-5.com/). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 4. System will be attached to the metal roofing material utilizing the patented S-5 connection. Installation of the connections shall be in accordance with the manufacturer’s recommendations. 5. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 48” o/c. 6. Panel supports connections shall be staggered to distribute load to adjacent trusses. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the FBC 2020, 7th Edition, current industry and standards, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Florida License No. 81558 Signed 11-18-21 1HOUSE PHOTOPV-0SCALE: NTSCOVER PAGEPROJECT SITESHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-0DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSSHEET INDEXPV-0COVER PAGEPV-1SITE PLANPV-2ROOF PLAN & MODULESPV-2ASTRING LAYOUT & BOMPV-3ATTACHMENT DETAILPV-3AATTACHMENT DETAILPV-4ELECTRICAL LINE DIAGRAM & CALCS.PV-4ASPECIFICATIONS & CALCULATIONPV-5SIGNAGEPV-6+EQUIPMENT SPECIFICATIONSSCOPE OF WORK:TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCELOCATED AT 60 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITYGRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT.THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIESEQUIPMENT SUMMARY17 JINKO SOLAR JKM375 -6RL3-B MODULES17 ENPHASE IQ7 PLUS -72-2-US (240V) MICROINVERTERSGENERAL NOTES:·THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS ANDOTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIREMODIFICATIONS IN CONSTRUCTION DETAILS.·ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION ORINSTALLATION OF ANY EQUIPMENT AT SITE.·CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALLPERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION.·CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONSAND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEERBEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATIONAND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THECONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONALCOMPENSATION.·DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL,FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THECONTRACTOR AT NO ADDITIONAL COST.·THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION ANDCOMPLETION OF THE WORK WITH APPROVED MATERIALS.·NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THEARCHITECT.·CONTRACTOR SHALL OBTAIN BULDING PERMIT. NO WORK TO START UNLESS BUILDINGPERMIT IS PROPERLY DISPLAYED.·ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCEWITH THE REQUIREMENTS OF THE FL BUILDING CODE, THE DEPARTMENT OFENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES.·IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALLPARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING.THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH.·ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TOBE PAINTED BY GENERAL CONTRACTOR.·THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THELOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE.·THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS,CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES.·CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK.ELECTRICAL NOTES:·THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON ISONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONSAND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(E) AND 705.6)·LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAPCONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF.·NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THECOORDINATION REQUIREMENTS OF OTHER TRADES.·ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL.·ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (NEC 314.15A).·WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATEDDIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING·BACK-FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES.·ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT.·CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN NEC 690 AND IFC 2018·PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONNECTION, AND SPLICES. THE MEANS OF IDCAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. (NEC 690.4).·MEASURE THE LINE-TO-LINE AND LINE-TO-NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PROIR TO INSTALLING ANY SOLAREQUIPMENT. THE VOLTAGES FOR THE 240VAC RATED.WIRING AND CONDUIT NOTES:·ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITSPURPOSE AND APPROVED FOR THE SITE APPLICATIONS·ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PVWIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR,OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINERBOXES AS REQUIRED·ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIEDACCORDING TO [NEC 690.8 (A)(1) & (B)(1)], [NEC 240] [NEC690.7] FOR MULTIPLE CONDUCTORS·ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHTSHALL BE DERATED ACCORDING TO [NEC TABLE 310.15(B)(2)(C)] BLACK ONLY**·EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°CRATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECTWIRE FROM SHARP EDGES·PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATEDTHHN/THWN-2 INSULATED, 90°C RATED, WET AND UVRESISTANT, RATED FOR 600V PER NEC 2008 OR 1000V PERNEC 2011·4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITHTHE HIGHER VOLTAGE TO GROUND MARKED ORANGE ORIDENTIFIED BY OTHER EFFECTIVE MEANS·ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCECIRCUIT PROTECTION·VOLTAGE DROP LIMITED TO 2%·NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BECOLOR CODED AS FOLLOWS: DC POSITIVE - RED (OR MARKEDRED), DC NEGATIVE - GREY (OR MARKED GREY)·POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLORCODED: DC POSITIVE - GREY (OR MARKED GREY), DCNEGATIVE - BLACK (OR MARKED BLACK)·AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASEA OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE,NEUTRAL- WHITE/GRAY1VICINITY MAPPV-0PROJECT SITESCALE: NTSPROJECT SITESYSTEM RATING6.38 KWDC5.02 KWACGOVERNING CODES2018 NFPA 1 (FIRE CODE)2017 NATIONAL ELECTRICAL CODE2020 FLORIDA BUILDING CODE (7TH EDITION) Signed 11-18-21 MSPUMLCAC24'-7"9'-5"7'-0"34'-7"133'-11"55'-2"143'-0"55'-11"PLOT PLAN WITH ROOF PLANPV-1SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-1DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSSITE NOTES·A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS.·THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES.·THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS.·PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED.1SCALE: 3/32" = 1'-0"SITE PLAN(N) NON FUSED AC DISCONNECTROOF #1(17) JINKO SOLAR JKM375 -6RL3-B MODULESTREES(E) DRIVEWAY(N) LOAD CENTER(E) MAIN SERVICE PANEL(E) UTILITY METER MEDITERRANEAN BLVD EPROPERTY LINEPROPERTY LINE1-STORYHOUSEPROPERTY LINEPROPERTY LINE Signed 11-18-21 36" FIRE SETBACK36" FIRESETBACK18" FIRE SETBACK 18" FIRE SETBACKMSPUMLCACJB31'-7"30'-7"13'-8"5'-1"11'-3"3'-2"ROOF PLAN & MODULESSCALE: 1/8" = 1'-0"ROOF PLAN &MODULESSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-2DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSJINKO SOLARJKM375 -6RL3-BMODULES73.03"40.51"(N) 3/4" EMT CONDUITARRAY AREA & ROOF AREA CALC'SROOF# OFMODULESARRAYAREA(Sq. Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVERED BYARRAY (%)#117323.791152.3828MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES:17 MODULESMODULE TYPE:JINKO SOLAR JKM375-6RL3-BMODULE WEIGHT:47.40 LBSMODULE DIMENSIONS:73.03" x 40.51" = 20.54SFUNIT WEIGHT OF AREA:2.31 PSFROOF DESCRIPTIONROOFROOFTILTAZIMUTHRAFTERSIZERAFTERSPACINGROOF MATERIAL#123°180°2"X6"12" o.c.CORRUGATEDMETALLEGEND- VENT, ATTIC FAN (ROOF OBSTRUCTION)- ROOF ATTACHMENT- CONDUIT(N) AC DISCONNECT(E) UTILITY METER(N) JUNCTION BOX(N) LOAD CENTER(COMBINER PANEL)UMACLC(E) MAIN SERVICE PANEL (MSP)MSPJBPV-21DESIGN SPECIFICATIONRISK CATEGORY:IICONSTRUCTION:SFDZONING:RESIDENTIALSNOW LOAD (ASCE 7-16):0 PSFEXPOSURE CATEGORY:BCWIND SPEED (ASCE 7-16):158 MPHROOF #1(17) JINKO SOLAR JKM375 -6RL3-B MODULES(N) UNIRAC SOLARMOUNT LIGHT RAIL(17) ENPHASE IQ7 PLUS -72-2-US (240V) MICROINVERTERS(35) S 5! VERSA BRACKET @ 48" o.c.(N) JUNCTION BOXROOF #1TILT - 23°AZIM. - 180°(E)FRONT OF RESIDENCE MEDITERRANEAN BLVD E (E)BACK OF RESIDENCE PANEL HEIGHT OFF ROOF 4"(N) NON FUSED AC DISCONNECT(N) LOAD CENTER(E) MAIN SERVICE PANEL(E) UTILITY METER Signed 11-18-21 36" FIRE SETBACK36" FIRE SETBACK18" FIRE SETBACK18" FIRE SETBACKMSPUMLCACJBROOF PLAN WITH STRING LAYOUT & BOMSCALE: 1/8" = 1'-0"SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-2ADATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSSTRINGLAYOUT & BOMPV-2A1- MODULE STRINGINGAB(E)FRONT OF RESIDENCE MEDITERRANEAN BLVD E (E)BACK OF RESIDENCEA-1BILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONSOLAR PV MODULE17JINKO SOLAR JKM375 -6RL3-BMICROINVERTER17ENPHASE IQ7 PLUS -72-2-US (240V)JUNCTION BOX1JUNCTION BOX, NEMA 3R, UL LISTEDCOMBINER BOX1ENPHASE IQ COMBINER W/ IQ ENVOY (X-IQ-AM1-240-3)AC DISCONNECT130A NON FUSED AC DISCONNECT, 240V, NEMA 3R, ULLISTEDATTACHMENT35S-5! PROTEA BRACKETATTACHMENT1751" SELF TAPPING SCREWENPHASE Q CABLE17ENPHASE Q CABLE 240V (PER CONNECTOR)BRANCH TERMINATOR2BRANCH TERMINATORIQ WATER TIGHT CAP0IQ WATER TIGHT CAPSRAILS9UNIRAC SOLARMOUNT LIGHT RAIL (168")BONDED SPLICE6BONDING SPLICEMID CLAMP30MODULES CLAMPS (MID CLAMPS)END CLAMP8MODULES CLAMPS (END CLAMPS)GROUNDING LUG2GROUNDING LUGA-2A-3A-4A-5A-6A-7A-8B-1B-2B-3B-4B-5B-6B-7B-8B-9 Signed 11-18-21 SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-3DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSATTACHMENTDETAILENLARGED VIEW OF ATTACHMENTPV-3ATTACHMENT DETAILSPV-3SCALE: NTS21SEE (2/PV-3) FORENLARGED VIEWMID CLAMPUNIRAC SOLARMOUNT LIGHT RAILPV MODULES5! PROTEA BRACKETPV MODULES5! PROTEA BRACKET1" SELF TAPPING SCREWUNIRAC SOLARMOUNT LIGHT RAILCORRUGATED METAL8MM HEX HEAD W/WASHER Signed 11-18-21 SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-3ADATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSATTACHMENTDETAIL Signed 11-18-21 (N) ENPHASE IQCOMBINER 3(X-IQ-AM1-240-3)10A/2PENVOY20A/2PJUNCTION BOX600 V, NEMA 3R,UL LISTEDG08- JINKO SOLAR JKM375 -6RL3-B MODULESBRANCH 109- JINKO SOLAR JKM375 -6RL3-B MODULES2BRANCH 2L2L1L2L1GQ CABLE120A/2P(17) ENPHASE IQ7 PLUS -72-2-US (240V) MICROINVERTERS4AC DISCONNECT:240V, 30A NON FUSEDNEMA 3R, UL LISTED3L1L2L1L2L1L2L1L2L1L2L1L230A/2PEXISTING GROUNDELECTRODE CONDUCTOR(E) MAIN SERVICEPANEL, 150A RATED,1-PH, 3-W, 240VBI-DIRECTIONAL UTILITYMETER# ACD98561-PH, 3-W, 120V/240VTO UTILITY GRID(E) MAIN BREAKER TOHOUSE 240 V, 150A/2PBACK FEED BREAKER ATTHE OPPOSITE END OFTHE MAIN BREAKERL2L1L2L1NNGGSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-4DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSELECTRICAL LINE1ELECTRICAL LINE DIAGRAMPV-4SCALE: NTSSERVICE INFO.UTILITY PROVIDER:MAIN SERVICE VOLTAGE:MAIN SERVICE PANEL:MAIN BREAKER RATING:MAIN SERVICE LOCATION:SERVICE FEED SOURCE:&CALCS.UNDERGROUNDFP&LIDTYPICALINITIAL CONDUCTORLOCATIONFINAL CONDUCTORLOCATIONCONDUCTORCONDUIT# OFPARALLELCIRCUITSCURRENT-CARRYINGCONDUCTORS INCONDUITCONDUIT FILLPERCENTOCPDEGCTEMP. CORR.FACTORCONDUITFILL FACTORCONT.CURRENTMAX.CURRENTBASEAMP.DERATEDAMP.TERM.TEMP.RATINGLENGTHVOLTAGEDROP12ARRAYJUNCTION BOX12 AWGQ CABLE--12N/AN/A6 AWGBARECOPPER0.76(55°C)N/A10.9A13.6AN/AN/A90°C36FT0.38%21JUNCTION BOXIQ COMBINER BOX10 AWGTHWN-2COPPERMIN 0.75" Dia EMT2419.09%20A10 AWGTHWN-2,COPPER0.96(33°C)0.810.9A13.6A40A30.7A90°C38FT0.45%31IQ COMBINER BOXNON FUSED ACDISCONNECT10 AWGTHWN-2COPPERMIN 0.75" Dia EMT1315.27%N/A10 AWGTHWN-2,COPPER0.96(33°C)120.6A25.7A40A38.4A90°C5FT0.11%41NON FUSED ACDISCONNECTMSP10 AWGTHWN-2COPPERMIN 0.75" Dia EMT1315.27%30A10 AWGTHWN-2,COPPER0.96(33°C)120.6A25.7A40A38.4A90°C5FT0.11%150A150ANORTH240VMAIN SERVICE PANEL MNFT.:EATONINTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED150A A + 30A = 180ABUSS RATING x 120%150 A x 120% = 180A Signed 11-18-21 SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-4ADATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSSHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-4ADATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSSPECIFICATIONSPERCENT OF VALUESNUMBER OF CURRENTCARRYING CONDUCTORSIN EMT0.804-60.707-90.5010-20&INVERTER SPECIFICATIONSMANUFACTURER / MODELENPHASE IQ7 PLUS -72-2-US(240V)MAX DC SHORT CIRCUITCURRENT15 ACONTINUOUS OUTPUTCURRENT1.21A (240V)VRise = (amps/inverter × number of inverters) × (resistance in Ω/ft) × (2-way wire length in ft.)= (1.21 amp ×9 ) × (0.00129 Ω/ft) × (38 ft × 2)= 10.89 amps × 0.00129 Ω/ft × 76 ft= 1.07 volts%VRise = 1.07 volts ÷ 240 volts = 0.45%The voltage rise from the Junction Box to the IQ Combiner Box is 0.45%VRise = (amps/inverter × number of inverters) × (resistance in Ω/ft.) × (2-way wire length in ft.)= (1.21 amp × 17) × (0.00129 Ω/ft) × (5 ft. × 2)= 20.57 amps × 0.00129 Ω/ft × 10 ft.= 0.26 volts%VRise = 0.26 volts ÷ 240 volts = 0.11%The voltage rise from the IQ Combiner Box to the AC Disconnect is 0.11%Voltage rise from the IQ Combiner box to AC DisconnectVoltage rise from the Junction Box to the IQ Combiner boxVoltage rise in Q Cable from the Microinverters to the Junction BoxFor branch circuit #1 of 8 IQ 7+ Micros, the voltage rise on the 240 VAC Q Cable is 0.31%VRise = (amps/inverter × number of inverters) × (resistance in Ω/ft) × (2-way wire length in ft.)= (1.21 amp × 17) × (0.00129 Ω/ft) × (5 ft × 2)= 20.57 amps × 0.00129 Ω/ft × 10 ft= 0.26 volts%VRise = 0.26 volts ÷ 240 volts = 0.11%The voltage rise from the AC Disconnect to the Main Service Panel is 0.11%Voltage rise from the AC Disconnect to the Main Service PanelTotal system voltage rise for all wire sections0.38 % + 0.45% + 0.11% + 0.11% = 1.05%CALC.SOLAR MODULE SPECIFICATIONSMANUFACTURER / MODELJINKO SOLAR JKM375 -6RL3-BVMP36.80 VIMP10.19 AVOC44.12 VISC11.01 ATEMP. COEFF. VOC-0.28 %/°CPTC RATING349.5WMODULE DIMENSION73.03" (L) x 40.51" (W)PANEL WATTAGE375WFor branch circuit #2 of 9 IQ 7+ Micros, the voltage rise on the 240 VAC Q Cable is 0.38%AMBIENT TEMPERATURE SPECSRECORD LOW TEMP0°CAMBIENT TEMP (HIGH TEMP 2%)33°CCONDUIT HEIGHT0.5"ROOF TOP TEMP90°CCONDUCTOR TEMPERATURE RATE55°CMODULE TEMPERATURE COEFFICIENT OF VOC-0.28 %/°C Signed 11-18-21 SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-5DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSSIGNAGEADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]PV ELECTRICALEQUIPMENT LAYOUTROOFTOP PVMODULES(E) MAIN SERVICE PANEL(E) UTILITY METER(N) NON FUSED AC DISCONNECT(N) LOAD CENTERMSPUMLCACLABEL LOCATION:CONDUIT, RACEWAY, ENCLOSURES,COMBINER BOX & AC DISCONNECT(PER CODE: NEC2017, 690.31(G)(3)(4)WARNINGPHOTOVOLTAIC POWER SOURCELABEL LOCATION:AC DISCONNECT/ BREAKER/POINTS OF CONNECTION(PER CODE: NEC2017, 690.13(B)PHOTOVOLTAICAC DISCONNECT2354LABEL LOCATION:AC DISCONNECT(PER CODE: NEC2017, 690.53)LABEL LOCATION:RAPID SHUTDOWN (AC DISCONNECT)PER CODE: NEC 690.58 (C)(3)RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMRATED AC OUTPUT CURRENT17ANOMINAL OPERATING AC VOLTAGE240VPHOTOVOLTAIC AC DISCONNECTLABEL LOCATION:COMBINER BOX/ EMT ENCLOSURES/AC DISCONNECT/ MAIN SERVICE PANEL(PER CODE: NEC 2017, 690.13(B))1LABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 2017, 705.12(B)78TREMINALS ON BOTH THE LINE ANDLOAD SIDE MAY BE ENERGIZED INTHE OPEN POSITIONWARNINGSOURCES: UTILITY GRIDAND PV POWER SOURCEELECTRIC SYSTEMWARNINGDUAL POWER SUPPLYDO NOT TOUCH TERMINALSELECTRIC SHOCK HAZARDLABEL LOCATION:RAPID SHUTDOWN (AC DISCONNECT)PER CODE: NEC 690.56 (C)(1) ANDNFPA 11.1.12.2.1.1.1.1 & 11.12.2.1.4SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMSOLAR ELECTRICPV PANELSEMERGENCY RESPONDER6LABEL LOCATION:POINT-OF-INTERCONNECTION OR AT MAINSERVICE DISCONNECT (MSP)PER CODE: NEC 705.12(B)(2)(3)(b)! WARNING !INVERTER OUTPUT CONNECTION. DO NOTRELOCATE THIS OVERCURRENT DEVICE. Signed 11-18-21 SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-6DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSEQUIPMENTSPECIFICATION SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-7DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSEQUIPMENTSPECIFICATION SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-8DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSEQUIPMENTSPECIFICATION SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-9DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSEQUIPMENTSPECIFICATION SHEET NAMESHEET SIZESHEET NUMBERANSI B11" X 17"PROJECT NAME & ADDRESSPV-10DATE: 10/05/202160 MEDITERRANEAN BLVD E PORT ST. LUCIE, FL 34952 ROBERT BRAZEAU RESIDENCE PH.# : (941) 253-7444 Email: rdbrazeau@gmail.com Signature with SealREVDATEDESCRIPTIONREVISIONSEQUIPMENTSPECIFICATION