Loading...
HomeMy WebLinkAboutDrawingty 0 FIRC I ' I ' I ' I N 0 I n7 I O COI ' I I � I ' Proposed Land Purchase I -�j (*See 21-0414a) *Sketch �O of Legal 2311, _ Z N W `.200 `01 I 03 0 11, 1 2.0' ) I �. 12,00;0' ' 10.5' O 5 ' � + oco _h m o -► .. .. m 'n O >c z O N N Lnz o 0 �O o iw o0 m O ' " W v ao ; rn it o , o 14.43' D O UNIT 9 (OCCUPIED)MC z �' �---- 10-- S68*06' 17"W 1 16.17' (P) -- FIR I N 1 N 6' WF (CLEAR) i ----y ' 30.3' 63.7' -------------- COVERED 26.8' - ENTRY a, L4 0 W T OD I� I V ' 1 m FIRC N O i N � I 't j 3cf=l ich,� 21 UNIT 10 ml ONE—STORY L--I— RESIDENCE N SANITARY Ln Ln �CLEANOUT % 36.3' _r^ rn AX11g b Proposed Improvement; I 1 YX i41 I i a m B Digitally signed by _ . William B Bennett ryB e n n ett Date:, 2021.05.07 t° 11:50:55-04'00' WILLIAM B. BENNETT Professional Surveyor & Mapper Florida Certificate No. 6353 LB No. 7608 CONCRETE N DRIVEWAY I I � 1 I I S68006'17"W 135.39' (P) IN W OI (Wa LT1� 32.85' v N J 0 1 O� 01 O1. N tG� 1 0 10 O 10 1 O Q O ELECTRIC TRANSFORMER O LA .� FIRC UNIT 11 (OCCUPIED) \ LEGEND QS = SANITARY MANHOLE CONC = CONCRETE QH = HOTWIRE MANHOLE X = TELEPHONE RISER CL = CENTERLINE RIGHT OF WAY A = WATER METER EP = EDGE OF PAVEMENT A/C = AIR CONDITIONER PAD FIRC = FOUND 5/8" IRON ROD GEN = GENERATOR PAD & CAP (UNNUMBERED) WF = WOOD FENCE FIR = FOUND 5/8" IRON ROD DUE = DRAINAGE & UTILITY EASEMENT (UNNUMBERED) X = CABLE TELEVISION RISER D = DELTA ANGLE ± = PLUS OR MINUS L = ARC LENTH o = MAILBOX R = RADIUS X = LIGHT- POLE POB = POINT OF BEGINNING ❑E = ELECTRICAL SERVICE (P) = PLAT DIMENSION POC = POINT OF COMMENCEMENT L i i7r 12821,1NV11 - S['4E, . Vicinity Map (Not To Scale) LEGAL DESCRIPTION: Unit 10, CINNAMON VILLAGE HARBOUR RIDGE —Plat 3, according to the map or plat thereof, as recorded in Plat Book 24, at Page 18 ("A" through "E"), of the Public Records of St. Lucie County, Florida. LOT AREA: 12,370 Sq. Ft.; 0.32 Acres± STREET ADDRESS: 12821 NW Cinnamon Way, Palm City, Florida 34990. SURVEYORS' NOTES: 1. Bearings shown hereon are based on the West line of Unit 10 as platted and bears N 23'10'25" W. 2. Written dimensions take precedence over scaled dimensions and distances are not to be scaled for construction and/or design purposes. N 3 All distances and bearings are as field measured and are coincident with "PLAT" and description data unless otherwise noted. 4. This drawing is not valid without the signature and original raised seal of a Florida licensed Surveyor & Mapper. \� W 5. This survey is based upon a description furnished by the client, there has been p no search of the public records done by this office. 6. Property lies in Flood Zone "X" as scaled from the Notional Flood Insurance W -" Program Rate Map, Community Panel Number 12111CO260 J, with an effective p date of February 16, 2012. 7. This survey is not covered by professional liability insurance. 8. City water & sewer are available in this area. 9. This survey meets the required accuracy as shown in Ch. 5J-17.051 (2) (b) based on its expected use. 10. No underground utilities or improvements were located unless otherwise shown. - - - - 11. This plan information to be verified by contractor prior to construction. p Revised: Edit proposed improvement, WB, 05-07-21. <% % — P. CERTIFIED TO: KENNETH SPARLER Date of Last field work:04/27/2021 d,d;• `V nnett Bennett Surveying, Inc. 107 Augusta Court Jupiter, Florida 33458 tel: 772.336.4933 email: ben nettsurveying@yahoo.com Boundary Survey & Site Plan Prepared on the order of: Kenneth Sparler Field: JP/BB — Drawn: 21 Scale: 1 "=20' Sheet: 1 of 1 00 P, IT STRUCTURE.CRITERIA DESIGN: *THIS OVERALL DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 161 AND 20 OF THE 2020 FLORIDA }BUILDING BODE 7TH EDITION, BUILDING AND ALL OTHER APPLICABLE STANDARDS WIND CRITERIA: *VELOCITY: 150 MPH (3 SECOND GUST), EXPOSURE'C', RISK CATEGORY 1. FUR VELOCITY >100 MILES PER HOUR, IMPORTANCE FACTOR SHALL = 0.77. SCREEN DESIGN: *18 X 14 SCREEN WALLS: WW PRESSURE @ 19.6 PSF, LW PRESSURE @ 15.6 PSF, ROOF @ 5.4 PSF DESIGN PRESSURE ON BUILDING ENVELOPE ELEMENTS: *PER THE ALLOWABLE STRESS DESIGN FOUND ON TABLE 2002.4 AND 2002.4A OF THE FLORIDA BUILDING CODE. *THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN IN THE DRAWING. THE ACTUAL SPACING BETWEEN ANY TWO BEAMS M;)ST BE THE AVERAGE SPACING, +/r 2", AND THE CENTER TO CENTER MUST NEVER BE GREATER THAN 8041: *EXTERIOR GLAZED OPENINGS SHALL BE PROTECTED BY PRODUCTS WHICH MEET THE REQUIREMENTS OF SSTD 12. ! SCREEN ENCLOSURE ROOF TYPE *A=FRAME ROOF ENCLOSURE WITH 3'0" RISE MAX. STRUCTURE IS CONNECTED TO EXISTING SINGLE STORY,-C.B.S. HOME WITH WOOD FASCIA. (SEE CONNECTION DETAIL 4 ON PAGE4). CONCRETE; *THIS ENCLOSURE WILL BE CONSTRUCTED ON AN EXISTING PAVER PATIO, WITH A NEW 8" X 8" CONCRETE FOOTER AROUND Ep,�RQME.TER WITH 1 #5 BAR CONTINUOUS. THIS FOUNDATION IS ACCEPTABLE FOR THIS ENCLOSURE. *ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 12" ON CENTER W/2-1/4" MIN:,EMBEDMENT INTO CONCRETE. ALUMINUM NOTES; MATERIALS SHALL CONFORM TO THE F.B.C., CHANGES SHALL BE DESIGNATED BY THE ENGINEER OF RECORD: 1: ALL EXTRUSIONS: ALUMINUM ALLOY #6005-T5 OR 6061-T6, (NOTE: SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALUM(NU!M ALLOY 6061-T6, IF THIS ALLOY IS MORE READILY AVAILABLE). 2: FASTENERS: ALUMINUM ALLOY # 2024-T4 & #7075-T6 DOUBLE CAD -PLATED STEEL, HOT DIPPED GALVANIZE:b STEEL OR 300-SERIES STAINLESS STEEL 3: MATERIAL UPGRADES (STRONGER OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME. 4: NO EXPANSION BOLT MAY BE INSTALLED WITHIN 2" OF EDGE OF CONCRETE SLAB. 5: NON STRUCTURAL ALUMINUM SHALL HAVE A MINIMUM THICKNESS- NO LESS THAN 0.032" (KICKPLATES ETC.) 6: ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH ALKALI RESISTANT COATING. 7: ALUMINUM IN CONTACT WITH WOOD SHALL BE PAINTED WITH TWO COATS OF HEAVY BODIED BITUMINOUS PAINT. 8: SELF MATING BEAMS (SMB) UP TO 8" TO BE FASTENED WITH BEAM STITCH SCREWS @ 16" O/C BOTH SIDES. (#12 SMS), FOR 9" & 10" SELF MATING BEAMS (SMB) TO BE FASTENED WITH BEAM STITCH SCREWS a@ 12" O/C. )�(O?_ RE` IEN .E Ti . LUO rw02 r CONCRETE SPECIFICATION NOTES AND DESIGN PARAMETERS 1)- 6" X 6" 10/10 WWM OR FIBERMESH ADDED CONCRETE. 2)- TERMITE TREATED SOIL WHEN NEXT TO LIVING SPACE. 3)- FOOTER SHALL BE 8" X 8" FOR PERIMETERS WITH ONE (1) #5 REBAR CONTINUOUS FOOTING SEE CONNECTION 1 ON PAGE 5 3000 PSI CONCRETE FILLER co 8" 1- #5 BAR CONTINUOUS �� FOOTER ELEVATION LLJ >- Q W Z � m O �C)M O W <LL D �= z z z Q LLJ CU U w�N� Q 0 J z�c c cw U4 0) N Z-�F- am � EEL = N WVOVwZ 3.W J W i LY co a LLJ 00 o 1- zU M W W 7 ti N 04 Il- U z Lo �C C zvLL T /^/ v/ c LL co J cWn�00 o z Via~ Q N Z W Q z 0 s a o0) z Z QO ' zQ ® z> � gw �fw1 W SHEET NUMBER 2OF6 m r— O z D Cgf% m r D O z C0 w= O m PLANS -n z AND 0 W ELEVATIONS X 0 n O I n 1 W m � N ' X n C9 1 )9 m >� n D K Lewsw FINO'S SCREEN AND ALUMINUM CO. 2789 SE GRAND DR. P.S.L. FL. 34952 PHONE 772-708-5761 Ln m m m z O O n AJ . r D z m �J -J 01 W 0 W N W X cT� N X N X N X N X N X N )G N N N W N W q OD m m W r r r r r r r r X v- `a: 00 000 00 0 �-�m O w O cyl O m O IM —4 N = v oc x i- 00000000 „zm O O 6) O W N ? i (n p x x x m z z m m �' Z Z Z Z Z Z Z Z z Wv� �000 <n 0 0y--19 � > ;u ng r mWFz JuL 2 20i1 SCREEN ENCLOSURE PAUL WELCH INC. MECH-ELECT-CIVIL ENG SPARLER RESIDENCE 1984 BILTMORE ST. #114 12821 CINNAMON WAY. PORT ST.LUCIE FL. 32984 PALM CITY FL. 34990 PAUL WELCH P.E. FLA. REG.No. 29945 SLPICE PLATE ALLOY: MITER SPLICES SHOWN FOR MANSARD SPLICES, IDENTICAL 6061T6 OR 5052H32 SPECIFICATIONS FOR GABLE AND/OR STRAIGHT BEAM SPLICES C7 0 V: 0 0 0 0 0', INTERNAL SPLICE 0 0 �a PLATE 111l COZ tz �109 SCREW POSITIONS NEAR MITE PE ZP8 pE SCREW POSITIONS NEAR MITER JOINT MAY BE ADJUSTED �ENGZN TO ACCOMODATE PURLIN, SPACE BETWEEN FASTENERS ALONG MITER JOINT MAY 1 1/2" TO 2", MANTAIN MAXIMUM AND MINIMUM DISTANCES BETWEEN SCEWS. EDGE DISTANCE FOR SCREWS: 3/4" MINIMUM SCREW SPACING: 5/8" • SPLICE SPECIFICATIONS PER TABLE 109 BELOW I rIV/1V "1-"VP%I IVIN rVfR vGMm ITII I GI% vrLwG A (DETAIL MAY BE ROTATED FOR GABLE RIDGE SPLICE, AND MAY I ALSO SERVE AS SPECIFICATIONS FOR A STRAIGHT SPLICE, MANTAIN PLATE AND CONNECTOR SPECIFICATIONS IN TABLE 109 FOR ALL) BEAM SLPICE DETAIL TABLE 109 BEAM 914 SMS PER SIDE PER END TOTAL #14 SMS PER SPLIC FASTENER SPACES THICKNE LENGTIHEIGTH NUMBER OF SPACE EHORIZONTALVERTICA 2X6X0.050X0.120 SM 3/16" 16" 51/4" 14 56 3 3 2X7X0.055X0.120 SM 3/16" 16" 61/4" 14 '56 3 3 2X8X0.072X0.224 SMB 3/16" 1 18" 1 71/4" 16 1 4 2X9X0.082XO.306 SM 3/16" 1 18" 81/4" 18 72 1 4 4 2X10X0.092X0.389 SM 1/4" 1 20" 1 9" 1 22 -'1 88 1 4 6 3 IF DESIRED THE 3/6" BOLT SHOWN IN THE WIND BRACING CONNECTION THAT SECURES THE 2 X 2 X 0.90 MEMBER TO THE U-BRACKET AND THE U- BRACKET TO THE ROOF BEAM CAN BE REPLACED WITH FOUR (4) $14 SMS. THE #14 SMS. MUST BE 1/2" FROM THE END OF THE U-BRACKET AND AT LEAST 3/4' APART (STAGGERED) FROM EACH OTHER. (U-BRACKET CHANNEL INSIDE VIEW WITH 4014 SMS INTO BEAM OR PERLIN) PURLING 1/4" THROUGH BOLT U-BRACKET (CHANNEL) # 14 SMS TWO ON EACH SIDE OF BRACE (U-BRACKET CHANNEL) ROOF BEAM 1/8" OD FENDER # 14 SMS TWO ON EACH SIDE OF BRACE 1/4" THROUGH BOLT ALTERNATE CONNECTION OF CHANNEL (4) EACH 014 SMS THRU CHANNEL WEB THRU BEAM WEBINTO BACKING PLATE E ° tM4 SIAS (TYPICAL) POSTICOLUMN- IIAGONAL K-BRACE PARTIAL ELEVATION/ UPPER K-BRACE AT EAVE RAIL (SCREEN SIDE) K BRACE SCREEN SIDE GUSSET PLATE SPECIFICATIONS: 1) ALLOY 6063T6 OR 6061T6 OR 5052H32 2) MINIMUN THICKNESS .090" ON THE OUT SIDE FLAT BAR AND .0625 ON THE INSIDE 1"X3" ANNGLE PLATE 3)SIZE SUFFICIENT TO ACCOMODATE #14 SMS AT A MINIMUM SPACING AND EDGE DISTANCE 1/2" 4)EQUAL NUMBER OF SCREWS INTO VERTICAL AND HORIZONTAL MEMBERS (INSIDE AND OUTSIDE) PARTIAL ELEVATIONILOWER K-BRACE AT SOLE PLATE (SCREEN SIDE) 1" x 3" x.09375 ANGLE INTERIOR ANGLE( LENGTH EQUAL TO DEPTH OF SCREEN SIDE TE). SECTION / K-BRACE CONNECTION (INSIDE) "Z" GUTTER INSERT IN SUPER GUTTER TO HOUSE CONNECTION 10" LONG (0.125 THICK) EXTRUDED 7' BAR GUTTER INSERT, TYP. CENTERED ON EACH ROOF BEAM, WITH (4) FOUR # 14 TEKS THRU TOP LIP OF GUTTER 5"STRUCTURAL GUTTER(CONT.) 1 O 4-1/4"X 21/4" LAGS IN EACH 10" INCH INSERT AND AT 24" O.C. (MAX. SPACING) IN THE REST OF THE GUTTER (PILOT DRILL FASCIA W/5/32" BIT TO AVOID SPLITTING) >I 1X2 SCREEN FRAME o • o 0 "Z" GUTTER INSERT SUPER GUTTER 2"X3" X 0.125" (CUT 2" LONG) WITH 3-INCH LEG G• AGAINST 1X2 CLIP, SHALL HAVE FOUR (4) # 14 GUTTER ELEVATION INTO SIDE OF ROOF BEAM AND TWO (2) #14 X 2" LONG TEKS (PER ANGLE CLIP) TRHU TYP. 2X? SCREEN ROOF BEAM GUTTER AND INTO GUTTER INSERT(TYP. ONE (MAY BE FLAT OR SLOPED) ANGLE CLIP ON EACH SIDE OF EACH BEAM 4 TOP VIEW PLAN r1i l ALUM.POST BRICK PAVERS 4 w 1'-4" X 1'4" X 2' WIN DEPTH • CONCRETE FOOTER #5 BAR X 12" LONG EACH WAY TRHU POST ISOLATED FOOTING DETAIL 2" X 27 2" X 3" OR 4- # 10 S.M.S. FROM INSIDE FACE OF 3" X 2" HOLLOW POST INTO SCREW SPLINES OF HORIZONTAL HOLLOW (GIRT). GIRT (1" EMBEDMENT MINIMUM.) - SELF MATING POST OR HOLLOW POST. PARTIAL ELEVATIONS/GIRT TO POST CONNECTIONS Wl CONCEALED FASTENERS ( 2 2"x 3" PURLIN MAY BE SLOPING OR HORIZONTAL A • • OVERLAP BEAM WITH 2- #12 S.M.S ON EACH SIDE 2 EACH #10 S.M.S X 4" COLUMN (PER LONG THRU EAVE RAIL TABLE) 2X2 INTO SLOPING PURLIN SCREW SPLINES END WALL PERLIN CONNECTION DETAIL 3 012 X 3/4• SMS @24' OIC. TOP 8 BOTTOM DBL, ALUM. BEAM F14 x3f4' SMS @24- O/C. TOP AND BOTTOM STAGGERED. 2- 318' THROUGH BOLTS W/1/r WASHERS. L�J- ALUM.POST DBL., BEAM FASTENING ROOF BEAM ROOF BEAM 2"X 2" PERLIN WITH 1 #14 INTO BEAM @ 16" PERLIN 0 ° 1-#14 X 3" 2" X 3" ANGLE 0 0 S.M.S. @ 12" ON EACH SIDE 0 0 2" X 3" ANGLE O.C. INTO OF BEAM WITH EACH SIDE BEAM. 3414 S.M.S. O BEAM WITH INTO EACH FRONT VIEW 3414 S.M.S. BEAM. INTO EACH BEAM. SIDE VIEW DBEAM ATTACHMENT TO FRONT WALL 2" X 3" PURLIN (MAXIMUM PURLIN SPACING T-0" ) SCREEN ROOF BEAMS - SIZE PER TABLE / MAXIMUM SPACING 8' - 0" O.C. BEAM STITCH SCREW @ 24" O.C. TOP AND BOTTOM (#12 SMS TYPICAL) 4 EACH #10 X 2" LONG S.M.S. (TYPICAL) INTO SCREW BOSSES. ROOF/SECTION OF CONCEALED FASTENER CONNECTION oa�0 O z pOce) Z W W WZL cj�? U LuvCU Q04 J 00 G7 e- G. C�4 ' (j UJ c ) uj 1w \ N Z5;Cf)LLa04 � uj ul cj � ul Lu -41 a o LL T O VILE COPY M O ti M Z U `' ti W � W N o N ti a� U z zMLL 3 to A D in J CO 0 O Z Q pan N ti uj L Z Z p Q 2 a SHEET NUMBER 5OF6