HomeMy WebLinkAboutTrussFLAlvs NKtVAKtU t-L) C: SYMBOL SAFE GRAVITY LENGTH LOAD LINTEL SCHEDULE APPLIED SAFE APPLIED GRAVITY UPLIFT UPLIFT LOAD LOAD LOAD COMPOSITE BEAM L1 4' - 6" 2189 190 1207 100 8F8-1 B-1 T 1631 190 2080 100 8F16-013-1T L2 5' - 10" 2189 600 1207 250 8F8-1 B-1 T L3 4'- 6" 2931 600 2707 250 8F16-0B-'IT L4 4'- 6" 2931 175 2707 6 8F16-013-1T L5 4'- 6" L6 4' - 6" 2931 175 2707 6b 8F16-013-1T 8F16-0B-1T L7 4' - 6" 2931 600 2707 250 L8 9' - 4" 2564 175 1474 65 125 8F20-1 B-1 T 8F16-1 B-1 T L9 16' - 8" 950 230 405 8F16-1B-'1T L10 9'-8" 1533 175 916 95 8F8-1 B-1T L11 4' - 6" _7 2189 705 1207 136 NOTE: 1. MINIMUM BEARING OF LINTEL SHALL BE 4" EACH SIDE FOR SPANS LESS THAN 10' - 0" 2. MORTAR SHALL BE TYPE M OR S 3. 8" BOND BEAM W/ #5 REBAR CONTINUOUS @ TOP OF WALL 4. COMPOSITE BEAM DEPTHS ABOVE ARE MINIMUMS. LINTELS MAY BE POt1RED DEEPER & 8" BEARING FOR SPANS GREATER THAN SPECIFIED. 1i,.__-F A FILLED 1trflTH € ROUT/ 11 & UNFILLED QUANTITY OF #5 4 FIELD ,ADDED RF9AR AT BOTTOM M OF U-LINTFOR V"ITY LOAD 1 -1 NOMI L �D'11B — QUANTITY OF RY 1 II L ? ADDED P1=BA-R AT TCP a^ NOMINAL K GHT COII po S! -E U-LINTEL F -R LI L-IFTI_04.G #5 F 1-D �' DDED REBAR AT J. I cm) 011- COMINU S I l E U -LI 1EL WC 11)AUD 11frCLEAR - FIR D PI ACF0C_W11_ n " G.ROUT #5 FIELD AMED RfDAR AT B01 fC Ot U-LIN 1 EL CAVITY Ho I I`I &I RHNFtN LING ? _541�" ACTUAL PROVIDED IN U LINTEL � t« ,LWEIt1` 1 JSFF fitllNl=tiRi_IFi!= 31F1 1E F1 THAN 10' - 0". 1 ROOF FRAMING PLAN S-2.0 SCALE: N.T.S. t Z3 Z� Z2 — Z2 Z1 Z2 Z Z2 10, Z, Z, "A" "A" z2 Z2 Z1 Z2 Z2 Z3 cz ) "A" i I_._ -- "A" ROOF SHEATHING NAILING ZONE (N.T.S.) ZONE ITEM 1 NAIL' AT 6" O.C. PERIMETER AND 6" O.C. FIELD 2 NAILS AT 6" O.C. PERIMETER AND 6" O.C. FIELD 3 NAILS AT 4" O.C. PERIMETER AND 6" O.C. FIELD NOTE: ROOF SHEATHING SHALL BE 19/32" THICK CDX PLYWOOD ROOF SHEATHING FASTENED TO ROOF FRAMIN3 WITH 8d RING -SHANK NAILS (PER FRC803.2.3.1) SPACED PER ZONE DESIGNATIONS AS SHOWN ABOVE. 6 Nail Pattern Esquema con b clavos PER NOA#12-0309.01 USE 6 NAILS PER SHINGLE PLACED AS SHOWN ABOVE. ENSURE THAT NO NAIL IS WITHIN,'" OF A JOINT/CUTOUT OF THE UNDERLYING SHINGLE. SEAL DOWN EACH SHINGLE AT TIME OF APPLICATION WITH THREE 1" 0 (APPROX. SIZE AND THICKNESS OF A QUARTER) SPOTS OF ASPHALT PLASTIC CEMENT PLACED UNDER THE SHINGLE. APPLY PLASTIC CEMENT IN MODERATION SINCE EXCESSIVE AMOUNTS MAY CAUSE BLISTERING. CAUTION: SHINGLES SHOULD SEAL TO THE UNDERLYING COURSE WHEN THE FACTORY APPLIED ASPHALT SEALANT IS SUFFICIENTLY WARMED BY THE HEAT OF DIRECT SUNLIGHT. SHINGLE NAILS SHALL BE GALVANIZED (ZINC COATED) ROOFING NAILS, 11 OR 12 GAUGE, 'KITH ATLEAST 3/8"0 HEADS, LONG ENOUGH TO PENETRATE THROUGH PLYWOOD OR 3/4" INTO BOARDS. UNDERLAYMENT SHALL BE INSTALLED AS PER MANUFACTURER'S INSTALLATION GUIDELINES. UNDERLAYMENT SHALL BE APPROVED 30# ROOFING FELT. UNDERLAYMENT APPLICATION: COVER THE DECK WITH ONE PLY OF UNDERLAYMENT LAID PARALLEL TO THE EAVES, WITH 2" HORIZONTAL LAPS AND 4" END LAPS. APPLY METAL DRIP EDGES ON TOP OF ANY UNDERLAY ALONG RAKE EDGES AND DIRECTLY TO THE DECK ALONG EAVES IN ACCORDANCE WITH BUILDING CODE REQUIREMENTS. FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE ENTERING THE WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE -PERMEABLE MATERIALS AND AT INTERSECTIONS WITH PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE. ALL FLASHING SHALL BE IN ACCORDANCE WITH FLORIDA BUILDING CODE. FLASHING SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR DIRECTION, AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION RESISTANT WITH A THICKNESS NOT LESS THAN PROVIDED IN FBC TABLE 1503.2. THIS REQUIREMENT DOES NOT APPLY TC HIP AND RIDGE JUNCTIONS. ALL ROOFING INSTALLATIONS SHALL BE IN ACCORDANCE WITH FBC 2014. Ili ZfA 1119lcm9LosII["a THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY TO MEET MANUFACTURER'S SPECIFICATIONS. DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. ENGINEERING LICENSE: 1FxAu,,,, r 7W... 1�1 - ')N A " � REVISIONS: DESCRIPTION IIOR PERMIT1 51 It NAllllt: PARCEL ID: 1301-606-0066-000-7 SALERNO RD FORT PIERCE, FL 34951 SAINT LUCIE COUNTY 511 E AUUKtbb: SALERNO rr .` FORT PIERCE, FL 3498,e SFltt I Utbt;KIN 1 1UNI: ■