r --x"FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 63 Block 1 Waterstone 1780 BGR
Builder Name: ADAMS HOMES
Street: 8617 Merano Avenue
Permit Office:
City, State, Zip: Fort Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1513.4 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1245.40 ft2
b. Frame - Wood, Adjacent
R=13.0 268.00 ft2
3. Number of units, if multiple family 1
-
c. N/A
R= ft 2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1780.00 ft2
6. Conditioned floor area above grade (ft2) 1780
b. Knee Wall (Vented)
R=19.0 120.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(177.0 sqft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 356
a. U-Factor: Dbl, U=0.33 113.31 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 45.94 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
0
SHGC: SHang
Area Weighted Average Overhang Depth: 2.639 ft.
.
14Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.272
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1780.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 52.71
Glass/Floor Area: 0.099
PASS
Total Baseline Loads: 52.75
I hereby certify that the plans aations covered b
of the plans and
&VUE
this calculation are in compli c ff11 the Florida erg�
specifications covered by this
Code. !'
calculation indicates compliance
!i���''a �,•":A'
�O
with the Florida Energy Code.
ti (►irr' '%2 „ r ���
PREPARED BY:
Before construction is completed
t �'
DATE: nR-f7-9n21 Winn Kpnmqny
this building will be inspected for
compliance with Section 553.908
�•
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
/ 5
with the Florid zt x erne
OWN ER/AGEN-T=-�
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.055 Qn for whole house.
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM FR405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 63 Block 1 Waterstone 17 Bedrooms: 3
User Conditioned Area: 1780
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 63-1
Block/Subdivision: Waterstone
PlatBook:
Street: 8617 Merano Avenue
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
j
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1780 15664
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1780 15664 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ftZ ---- 0.38 0 0.62
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1990 ftZ 446 ftz Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1780 ftz N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Knee Wall (Vented)
Under Attic (Vented)
Main 19 Batt
Main 30 Blown
120 ftz 0.11 Wood
1780 ftZ 0.11 Wood
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM k405-2020 INPUT SUMMARY CHECKLIST REPC)RT
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar Below
1 S
Exterior Concrete Block - Int Insul Main
4.1 40 0 8
0
320.0 ft2
0
0 0.6
0
2 W
Exterior Concrete Block - Int Insul Main
4.1 40 6 8
0
324.0 ft2
0
0 0.6
0
3 NE
Exterior Concrete Block - Int Insul Main
4.1 3 0 9
6
28.5 ft2
0
0 0.6
0
4 N
Exterior Concrete Block - Int Insul Main
4.1 11 10 9
6
112.4 ft2
0
0 0.6
0
5 NW
Exterior Concrete Block - Int Insul Main
4.1 3 0 9
6
28.5 ft2
0
0 0.6
0
6 E
Exterior Concrete Block - Int Insul Main
4.1 54 0 8
0
432.0 ft2
0
0 0.6
0
7 -
Garage Frame - Wood Main
13 33 6 8
0
268.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N Insulated Main
None
.25
3
6 8
20 ft2
2
Wood Main
None
.46
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
S 1 Metal Low-E Double Yes
0.55 0.7 N
17.8 ft2
14 ft 4 in 0 ft 10 in
None
None
2
S 1 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3
W 2 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
4
NE 3 Vinyl Low-E Double Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
5
N 4 Vinyl Low-E Double Yes
0.33 0.21 N
23.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6
NW 5 Vinyl Low-E Double Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7
E 6 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
591 ft2 591 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391 1827.5 100.26 188.23
.1312
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
6/7/2021 12:28 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM �R405-2020 INPt1T StIMMARY CI4I=rKI IRT RFPf1RT
r�
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ---
Air
CFM 25
CFM25
HVAC #
�/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 356 ft2
Main
89 ft2 Proposed Qn
Main
--- cfm
97.9 cfm 0.06
0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[ Jan HFeb
HeatinlX� Jan Feb
Mar
Mar
HX
A r
APr I
Jul
May Jun Jul
IMa rj Jun ri
X Au
AuSep
Se
ri
Oct
Oct
Nov
Nov
Hx
Dec
XDec
Ventin [ Jan Feb
Mar
[X] Apr
May JunJul
[ Aug
Se
[X]
Oct
Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORNI� R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
8617 Merano Avenue, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1245.40 ft2
b. Frame - Wood, Adjacent
R=13.0
268.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
3
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1780.00 ft2
6. Conditioned floor area (ft2)
1780
b. Knee Wall (Vented)
R=19.0
120.00 ft2
7. Windows** Description
Area
c. A
R=
ft2
a. U-Factor: Dbl, U=0.33
113.31 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 356
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
45.94 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
28.4 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
28.2
HSPF:8.50
Area Weighted Average Overhang Depth:
2.639 ft.
Area Weighted Average SHGC:
0.272
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2EF:0.94
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1780.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: \ Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
- wrightsoft®
Manual S Compliance Report
Entire House
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Project• •
For: ADAMSHOMES
8617 Merano Avenue, Fort Pierce, FL 34951
Cooling Equipment
Design Conditions
design DB:
90.4 OF
Sensible gain: 19263
Btuh
Outdoor design W B:
77.4 OF
Latent gain: 4018
Btuh
Indoor design DB:
75.0 OF
Total gain: 23281
Btuh
Indoor RH:
50%
Estimated airflow: 947
cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type:
SpIitASHP
Manufacturer:
Carrier
Model: 25HBC530AP03+FX4DNB031 L00
Actual airflow:
947
cfm
Sensible capacity:
21039
Btuh
109% of load
Latent capacity:
5956
Btuh
148% of load
Total capacity:
26995
Btuh
116% of load SHR: 78%
Heating Equipment
Design Conditions
Outdoor design DB: 41.0 cF Heat loss: 22296 Btuh
Indoor design DB: 70.0 OF
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Carrier Model: 25HBC530AP03+FX4DNB031 L00
Actual airflow: 947 cfm
Output capacity: 26646 Btuh 120% of load
Supplemental heat required: 0 Btuh
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 947 cfm
Output capacity: 6.6 kW 101 % of load Temp. rise: 22 OF
Meets all requirements ofACCA Manual S.
Job: Lot 63 Block 1 Waterstone...
Date: 06.07.12
By: FLETCH
Entering coil DB: 76.2OF
Entering coil WB: 63.2OF
Entering coil DB: 69.6°F
Capacity balance: 35 cF
Economic balance: -99 °F
-*- wrightsoft® 2021-An-0712:1623
nuaaimmnn• o mmwro Right-SutegUriversa12021 21.0.02 RSU23828 Page 1
ACCA aterstore1780BGR\Lot63BIk1Waterstore1780BGR.np Calc=MJB Housefaces: N
Component Constructions Job: Lot 63 Block 1 Waterstone...
wrightsoft® Date: 06.07.12
Entire House By: FLETCH
DEL -AIR HEATING & AIR CONDITIONING
531CODISCOWAY,,SANFORD,FL32771Phone: 407-333-2665Fax: 407-333-3853 Web:WWW.DEL-AIR.COM
eLroject intormation
For: ADAMS HOMES
8617 Merano Avenue, Fort Pierce, FL 34951
Design
C• • •
Location:
Indoor:
Heating
Cooling
St Lude Co Intl, FL, US
Indoor temperature (OF)
70
75
Elevation: 26 ft
Design TD (OF)
29
15
Latitude: 28 ON
Relative humidity (%)
30
50
Outdoor: Heating
Cooling
Moisture difference (grAb)
2.4
56.9
Dry bulb (OF) 41
90
Infiltration:
Daily range (OF) -
15 (L
) Method
Simplified
Wet bulb (OF) -
77
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft' Btu1V tMF ftz*FBtuh Btuh(fV Btuh Btuh/ft' Ruh
Walls
1613-19ad: Knee wall, asphalt shingles roof mat, r-19 kw ins, 1/2" gypsum
board int fnsh
Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gypsum board int fnsh
Partitions
12C-Osw: Frm wall, 1/2" gyp.bd ext, r-13 cav ins, 1/2" gypsum board int
fnsh, 2'k4" wood frm, 16" o.c. stud
n
30
0.049
19.0
1.42
43
2.59
78
e
30
0.049
19.0
1.42
43
2.59
78
s
30
0.049
19.0
1.42
43
2.59
78
w
30
0.049
19.0
1.42
43
2.59
78
all
120
0.049
19.0
1.42
171
2.59
310
n
68
0.201
4.1
5.83
399
4.06
278
ne
17
0.201
4.1
5.83
99
4.06
69
e
383
0.201
4.1
5.83
2232
4.06
1555
s
269
0.201
4.1
5.83
1571
4.06
1094
W
291
0.201
4.1
5.83
1698
4.06
1183
nw
17
0.201
4.1
5.83
99
4.06
69
all
1046
0.201
4.1
5.83
6098
4.06
4247
250
0.091
13.0
2.64
660
1.31
328
Windows
2A-2ov: 2 glazing, clr low-e outr, air gas, vnl frm mat, clr innr, 1/4" gap, 1/8"
n
23
0.330
0
9.57
224
8.22
193
thk; NFRC rated (SHGC=0.21); 50%drapes, medium; 1.3 ft overhang
ne
12
0.330
0
9.57
114
16.6
198
(5.3 ft window ht, 0.8 ft sep.); 6.67 ft head ht
nw
12
0.330
0
9.57
114
16.6
198
all
47
0.330
0
9.57
452
12.5
589
2A-2ov: 2 glazing, clr low-e outr, air gas, vnl fnn mat, clr innr, 1 /4" gap, 1/8"
a
49
0.330
0
9.57
469
22.4
1099
thk; NFRC rated (SHGC=0.23); 50% drapes, medium; 1.3 ft overhang
s
33
0.330
0
9.57
313
8.52
279
(5.3 ft window ht, 0.8 ft sep.); 6.67 ft head ht
W
33
0.330
0
9.57
313
22.4
733
all
114
0.330
0
9.57
1095
18.5
2111
10C-m: 2 glazing, dr low-e outr, air gas, mtl no brk frm mat, clr innr, 1 /4"
s
18
0.550
0
16.0
285
16.2
289
gap, 1/8" thk; NFRC rated (SHGC=0.70); 14.33 ft overhang (6.7 ft window
ht, 0.8 ft sep.); 6.67 ft head ht
Doors
11 JO: Door, mtl fbrgl type
n
20
0.600
6.3
17.4
350
17.6
353
` 11 DO: Door, wd sc type
n
18
0.390
0
11.3
202
11.4
204
wright.c ft-
2021-.Itat-0712:1623
w,.• �,.m..•". �mm Rigtd-Stite®Uriversal 2021 21.0.02 RSU23828
Page 1
aterstorte1780BGR1Lot63B1k1 Waterstone1780BGR.rtp Calc= W8 House faces: N
Ceilings
1613-30ad:Attic ceiling, asphalt shingles roof mat, r-30 cell ins, 1/2"
gypsum board int fnsh
Floors
22A-tpl: Bg floor, light dry soil, on grade depth
wrightsoft-
MCA �•+�..• _�-,�m Right-Sute®Uriversa1202121.0.02RSU23828
aterstonel780BGR1Lot63BIk1Waterstonel7BOBGR.np Calc=MJ8 Housefaces: N
1972 0.032 30.0 0.93 1830 1.69 3332
189 0.989 0 28.7 5425 0 0
2021-Jtsi-0712:1623
Page 2
Project Summary Job: Lot63 Block 1 Waterston...
-�- wrightsoft® Entire House By- F6LETCH
DEL -AIR HEATING & AIR CONDITIONING
531CODISCOWAY, SANFORD,FL32771 Phore:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
Proiect Information
For: ADAMS HOMES
8617 Merano Avenue, Fort Pierce, FL 34951
Notes: L. S. 6-7-21 VWK
DesicIn Information
Weather: St Lude Co Intl, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 41 OF
Outside db
90
OF
Inside db 70 OF
Inside db
75
OF
Design TD 29 OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
57
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 19749 Btuh
Structure
15373
Btuh
Ducts 2548 Btuh
Ducts
3889
Btuh
Central vent (0 cfm) 0 Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification 0 Btuh
Blower
0
Btuh
Piping 0 Btuh
Equipment load 22296 Btuh
Use manufacturer's data
y
Infiltration
Rate/swin multipplier
Equipmensensble load
1.00
19263
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0
Structure
2830
Btuh
Ducts
1188
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg Cooling
Area
(none)
(ft2) 1780 1780
Equipment latent load
4018
Btuh
Volume (ft3) 15760 15760
Air changges/hour 0.38 0.20
Equipment Total Load (Sen+Lat)
23281
Btuh
Equiv.AVF (cfm) 100 53
Req. total capacity at 0.75 SHR
2.1
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Carrier
Trade CARRIER
Trade CARRIER
Model 25HBC530AP03
Cond 25HBC530AP03
AHRI ref 204840289
Coil FX4DNB031 L00
Efficiency 8.5 HSPF
AHRI ref 204840289
Efficiency 12.5 EER,15
SEER
Heating input
Sensible cooling
21300
Btuh
Heating output 28200 Btuh cr 47OF
Latentcooling
7100
Btuh
Temperature rise 27 OF
Total cooling
28400
Btuh
Actual airflow 947 cfm
Actual airflow
947
cfm
Airflowfactor 0.042 cfm/Btuh
Air flow factor
0.049
cfm/Btuh
Static pressure 0.40 in H2O
Static pressure
0.40
in H2O
Space thermostat
Load sensible heat ratio
0.83
Capacity balance point = 35 OF
Backup:
Input = 7 kW, Output = 22460 Btuh,100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
��P. wrigt�tsoft' 2021-Jiur0712:1623
AI.t.�~ a RigN-Sute®Udversal2021 21.0.02 RSU23828
aterstore1780BGRU_ot63BIk1Waterstone1780BGR.nQ Calc=MJ8 Housefaces: N Page 1
- wrightsoft Right-M Worksheet
Entire House
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Jab: Lot 63 Block 1 Waterston 17...
Date: 06.07.12
By: FLETCH
1
Room name
Entire House
LAU
2
Exposed vvall
1892 It
7.0 ft
3
Room height
8.8 ft
8.0 ft heaV000l
4
Room dimensions
7.0 x 7.0 ft
5
Room area
1792.0 ftz
49.0 ftz
Ty
Construction
U-value
Or
HTM
Area z
(ft)
Load
Area (ft')
Load
number
Btuh/ftz
( `�
Btuh/ftz
( )
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/PiS
Heat
Cool
6
W : - -
-16B 19ad' - :.._�.._
_._ 0049
_ rj,`
_.1__
_259
.� 30
_., '30
_ __.._
_
_78
.__ .__._,0
_
-
Blk wall, stucco ext
0.201
n
5.83
4.06
112
68
399
278
0
0
0
0
2A-2ov
0.330
n
957
822
23
0
224
193
0
0
0
0
11J0_,____
0600
n_
17.40
17,58
20
20
350
353
0
0
0
0
11
wall; stu000 ext^
29
Y12
' 417
' 98
E 69
_
0
_
0
0
_ 0
_ . _---..:0330
..ne
_ _ 957
_ , _16 66
Y
__,_0
_.___11A
__.___ 198
,
.;___.,._0
____.-0
___.._.-_ 0
_ __0
W
166-19ad
0049
142
259
30
30
43
78
0
0
0
0
Blkvvall,siu000e#
0201
,e
a
583
4.06
432
383
2232
1555
0
0
.
0
__ ^ 0
.2A2&._ __ , ___-__..
_: __._0.330.__e._
____957
._._..22:43
...:.._.M49
_.:___:_..3
W
166&19ad
0049
s -
1.42
259
30
30
43
78
0
0
0
0
Blkvtellstu000eid
10C m
0201
0550
s
s
T 583
1595
' 4.06
1620
320
18
259
18
1571
285
- 1094
289
; 0
0
_ ._6
0
. _ ..._ 0
0
._-... _- _0
0
2A 2ov c
0 330
s ,
957
8 52
- - 33
_
33
313
279
0
0
0
,
0
W
16B-19ad,
0049
w
1 42
259.
.. _ 30
30
43
__ 78
_ 0
_ 0.
O
...0
W
LG
Blk +ell stucco ext
0201
w '
5.83
4.06
324
291
T696
1183
0
' -0
-0
-0
2A 2ov__-.�_ _._ .._
... _--.0.330
_ w_
_ ..957,
.__ _ 22A3
:__. _." .33
___ . ,_ - 2
:._ __ __313
__,733
_ t, __ ..0
0
.- _ _ __ .0
1�1
I-G
Blk veil, stucco eM
0.201
nw
5.83
4.06
29
17
99
69
0
0
0
0
2A-2ov
0330
nw
957
16.61
12
0
0
f
12C Osw
0091
264.
131'
268
' 250
...114
660
v Y198_0.
328
56
38
___._.0
', 101
_
50
--_
i1D0._.._.
_0390n_.
_.1131,_.._11.43
_.____18
_. 18
_'202----_.a204_.___..18_.
__.18_.___._202-___._:204
C
18B-30ad_
0.032
0.93
1.69
1972
1972
1830
3332
49
49
45
83
.F_ ._
,2.WI� ... .w_
0989
,. ;...,_
-,2868
_._._ 000
1792
_ ___ _ 189.�5425..
_0
6
c) AED ex .ion
0
-29
Envelopeloss/gain
16568
11764
549
308
12
a) Infiltration
3181
889
0
0
b) Roam ventilation
0
0
0
0
13
Internal gains: Oocupantspa 230
4
920
0
0
Appliances/other
1800
600
Subtotal (lines 6 to 13)
19749
15373
549
908
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
19749
15373
549
908
151
Ductloads 113%
25%
2548
3889
13%
25%1
71
230
Total room load
F
22296
19263
620
1138
Air required (cfm)
1
947
947
26
56
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-li.t- wr➢gF�tsoft- 2021-Jur0712:1623
Right-Sute®Unversal 2021 21.0.02 RSU23828 Page 1
aterstone1780BGR1Lot63BlkiWaterstore1780BGR.np CaIc=MJ8 Housefaces: N
-�- wrightsoft° Right-JO Worksheet
Entire House
DEL -AIR HEATING &AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phore:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
Job: Lot 63 Block 1 Waterston 17...
Date: 06.07.12
By: FLETCH
1
Room name
BR3
BATH2
2
Exposed wall
26.0 It
0 ft
3
Room height
8.0 it heat/000l
8.0 It heat/cool
4
Room dimensions
1.0 x 146.5 ft
9.0 x 6.0 It
5
Room area
1465 ft2
54.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ftz)
Load
Area (ftz)
Load
number
(Btuh/ftz-`q
(Btuh/ft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
_._25,
-__ _0
._._ _0
__..- _0
___.�__0
.� _ .�0
.__ ___0
V)/
�t-pG
Blk vdl, stucco e#
2A-2ov
0.201
0.330
n
n
5.83
957
4.06
822
0
0
0
0
0
0
0
0
0
0
0
0
__.____._0
0
0
0
0
11J0 _
0.600
n
17.40
17.58
9
0
0
0
0
11
V1/ L
___
Blk v�all, stucco e#
6201
ne
5 83
4.06
__.
0
_ ..-
0
_ __.._v
0
______.____0
0
_.____ .
0
_ ...--_-
0
,---
0
4 0
2A 2ov-_-_. .. _ , -
_. __ __0330
_ ne _,
____' 957
_. 16.61
___'_0
___�__0
___0
___0
_�_ „0
W
166-19ad
a
1.42
259
0
0
0
V)!
_
Bik viell siuoco e#
_0049
0201
e
5 83
'4.06
0
4 0,
0
0.
Y 0
0
0
-0
_._.(
2A2ov__ ____ _ _..,.
___.__:0330
__e_:
__ ._957,
z 22.43.
_ .. __,_0
_ __.._.e .0
._, ..._6
W
1613-19ad Y _
0049
s_
1.42
2.59
0
0
0
0
0
0
0
0
y/
Blk v�ell, stij000 eid -
10C m
0201
0.550
s
s
583
15.95
- 4.06
- 1620
` _0
0
_ ._ O
0
. ._ . 0
.. 0
_ _. _o
0
_...__ , ._ o
0
.- _ •--_ - o
0
. _ ., _ _ _0
0
...., O
0
�♦-GG
_
2A20v--
0330
s°.
957.w
w852
._ ._ _0-_0_
0
0
W
16B-19ad -
0.049
w„
1.42
259
0
0
_._;.:0,-.
0
-
0
-
0
- --0.__,_
0,,.
..._0
0
0
v�
Blkv+,all stu000e#
0201
w
5.83:
4:06
104
68
�'-511
356
", �0
-�- "_0
'�� -' • 0
_
0
�=G
2A2ov __ _ . .._._
____ .0336
__w_
.._ ,957,:
__'-22A3
___ .- 16._
.__." ..1
_--_ 156
_._ ._366._.__._
__0_-
_ --_b
V!/
Blk %dl, stucco e#
0201
nw
5,83
4.06
0
0
0
0
0
0
0
0
__G
2A 2ov
0330
nw
957
16.61
0
0
0
0
0
0
0
0
12C Osw 4
-091
".
2--a131
104
104
274
136
0
.-, - -0
-..-- _ 4
" - -$
:11 D0 • -_ ___- .r ._
.__ _0 390
n143
- _ _____0
w _._._0
.,_ . _ _. 0
v 0
a_ ._._,_0
_ ._ _. 0
C
166.30ad
0.032
0.93
1.69
147
147
136
248
54
-.
54
50
91
147
6
6
c) AED excursion
184
_3
Envelope loss/gain
1823
1290
50
88
12
a) infiltration
242
68
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
2066
1358
50
88
Less a#ernal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
2066
1358
50
88
15
Duct loads
13%
25 %
266
343
13 %
25 %
6
22
Total room load
2332
1701
57
111
Air required (clm)
99
84
2
5
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
'-tI'�• wrightsoft^
A Right-Srite®Uriversal 2021 21.0.02 RSU23828 2021-1in-071 :1a6e 2
aterstone1780BGR\Lot63BIk1 Waterstore1780BGR.rrp Calc= W8 House faces: N g
-+ wrightsoft, Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, R-32771 Phore:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Job: Lot 63 Block 1 Waterstone 17...
Date: 06.07.12
By. FLETCH
1
Room name
BR2
KER
2
Eased wall
13.0 8
32.5 ft
3
Room height
8.0 It heat/cool
8.0 ft heat/000l
4
Room dimensions
1.0 x 137.5 It
1.0 x 270.5 ft
5
Room area
137.5 ftz
2705 ftz
Ty
Construction
U-value
Or
HTM
Area (ft)
Load
Area (ftz)
Load
number
(Btuh/tz-'F)
(Btuh/ftz)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/PiS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
w16619ad:-.i_..�.._..0
Blkvall,stuceoext
2A-2ov
0201
0.330
n
n
5.83
957
4.06
822
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11JO_-
0.600
n
1.7.40
17.58
0
0
0._-__
00
11
_
BIk V�all; stuaoo eid
2ov__.__
0201
ne'
5 63
4.06
__ _-
0
p
__.. ____ _0
0
_.___
• 0
_.,._
0„
.__ _
'_
_- -�
--, .-0
_
.2A __
_, __ __0230
.ne-
__ . _ 957
_ ,_16.61
.._. -'-..--0
_ _ 0
_ 0
_.. _0
-._ _-0
___.0
___ __ ___0
W
1613-19ad
0049
a
142
2.59
0
0
0
0
0_
0
0
0
Blkvtell stu000eM
0201
a
583
406
0
0
0
0
_
0
0
0
0
.2A2ov._.. _,. _._
_...__ ...6,330
...e,_
_--957
,._ .,.22,43
_ 0
,,., _ ;_.a0
_ .._ ___0
...._. _.0
_:x:,.. 0
'_ :_.._, 1.0
L:------ .--- 0
...
W
1613-19ad Y
0049
-0201
s
1.42
2.59
0
0
0
0
0
0
0
0
Vjl
uk'vall,stu000e#
10C m
0550
-s
s -.
M 583
15.95
4.06
1620
- _..0
0
.._._.._ o
0
.__.__.. .0
0
_
- 0
0
_ 144
0
_
111
0
649
6
452
0
II --CC
2A2ov', ._.. _ _
0.330
"
s
957
8b2
0
0.
0
0
33
. 33
31
279
W
16B 19ad
0049
w
142
2.59
_0
0
0.._
0
_ ,
0
. .
0
0
Blk yell stu000 eK<
0201
w
5.83
4.06
.
104
- 88
511
._0
. .._356
__. -
116
_ 116
-"- 6' 6
- 471
.2A2ov____w.___.u.
_ __-_0.330
__w__
____957.1__22.43
__.__16:
1
__. _156
__..._-,366
_. _____.0
__.0
_ _0
__0
I-G
Blk wall, stucco ext
0.201
nw
5113
4.06
0
0
0
0
0
0
0
0
2A 2ov
0230
nw
957
16.61
0
0
0
0
0
0
0
0
R
12C Osw
0097
2.64
131
0
0
0
0
_ 0
_ o
.. _...:_ O
-,
11DQ
---- _ - - 0
--__..__0
_____0
-_ ._ -.0
- -0
C
16B•30ad
0032
-
093
1.69
138
138
128
232
01
271
252
458
„µ
7-7
6
c) AED excursion
188
-64
Envelope loss(gain
1168
1143
2822
1596
12
a) Infiltration
242
68
606
169
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
1
230
Applianoes/other
0
0
Subtotal (lines 6 to 13)
1410
1211
3427
1996
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1410
1211
3427
1996
15
Duct loads
13 %
25%1
182
306
13 %
25%1
442
505
Total room load
1592
1517
3870
2501
Air required (cfm)
68
75
164
123
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
'� cur➢g➢•�tsoft^
A Righ-Sulte®Unversal 2021 21.0.02 RSU23828 2021 Jur071 :16e 3
aterstore1780BGR\Lot63BIk1Waterstone1780BGR.rnp Calc=MJ8 Housefaces: N g
- wrightsoft- Right-JO Worksheet
Entire House
DEL -AIR HEATING &AIR CONDITIONING
531CODISCOWAY,,SANFORD,FL32771 Phone:407-333-2665 Fax:407-333-3853 Web:WWW.DEL-AIR.COM
Job: Lot 63 Block 1 Waterston 17...
Date: 06.07.12
By: FLETCH
1
Room name
NBATH
WIC
vvaJI
h
210 ft
75 ft
3
Room
height
8.0 ft heaUcnol
8.1 ft heat/cool
4
Room dimensions
1.0 x 116.0 ft
1.0 x 87.0 ft
5
Room area
116.0 ft2
87.0 ftz
Ty
Construction
U-value
Or
HTM
Area z
(ft)
Load
Area (ftz)
Load
number
(Btuh/ftz-'F)
(BtuM2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/PuS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
16619ad9049
'_6"'_,T.42
LBlk
-G
yell stuooD eud
2A 2ov
0.201
0.330
n
n
5B3
957
4.06
822
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
11,10 _
1740
17.58
0
0
0
0
0
0
0
0
11
Blk yell stu000 ext --
_0600
0201
_n_-
ne
583
4.06
-.
". 0
p
- p
-__ , 0
_�_ __-.0
____ __-_ 0
_ �_ __0
.- _ .__ 0
_-.--.0.330
_.,ne..
_ 957_
___16.61
__0
____._.-._0
0
_ ._0
W
16B-19ad
0049
e -
'
_ -1A2
�259
_0
0
0
0
0
0
0
0
Blk yell stucco ext
0201
e
5.83
4.06
-�
56
_
56
___ 326
___,
227
=_ 6
0
_ _ - _ 60
_ 350
244
.2A:: n....__ ._
_ ___-0.330
. e._
.__._ __957.
_._-22.43
_. _____,_0
_:._ ._..__'o
.._:___.:0
.�_ 4 s,..__0
__ _-,_...0
..__--.--0
W _
16B-19a2ov_ d
0049
s
1.42
259
0
0
0
0
0
0
0
0
Blk veil, stu000 ext:,
100 m
0201
0550
s
- s
5 83
1525
, 4.06
1620
y
-112
0
112
0
653
0
455
0
. _ , 0
0
._ . ._ 0
0
: _ __._.. _0
0
._ _ _-- .. 0
0
2A-2ov
0 330
' s `
957
852
0
, 0
0
166 19ad _ _
_ 0,.049
w
-w
_1,42
259
0
9
0
Blk cull, stucco ext
0201
_
.
5.83
4.06
_0
0
-___.,._.
0
.0
-9.
' 0
_ _ _..__
0
--- �. _0
0
_ .- _ ---0
'. 0
.__----
0
4 C
2A2ov___-._.
_-_--0.330_-w_
957-e_
22.43
-_----.0_
-__- __0__.
____0
_-..A0.._...____.0
Blk vall, stucco�__ext
0201
nw
5.83
4.06
0
0
0
0
0
0
�:;__.0:
0
_._. _ __:0
0
2A 2ov
0.330
nw
957
16.61
0
0
0
0
0
0
0
0
R
12C Osw
11D0,__c______1131._._.1143._,
0 091
2.64
131
0
0
_ 0
;. 0
_ 0
.. 0
- 0
0,
__-_0
-0
C
1613•30ad
0.032
023
1.69
116
116
108
196
88
88
81
148
F
22A1pl_-• - _
._.__ 0989._:_:
2868.
0.00
-
----_116
_
-----21
_ -602
-
_ -0
-
_- _ _87_
8
_ __ 215
-0
6
c) AED excursion
-31
-13
Envelope loss/gain
1689
848
646
378
12
a) Infiltration
391
109
140
39
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6to 13)
2081
957
786
417
Less external load
0
0
0
0
Lesstransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
2081
957
786
417
151
Dud loads
13 %
25%1
268
242
13 %
25%1
101
106
Total room load
2349
1199
887
523
Air required (c 1m)
100
59
38
26
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
-*- wrigF�tsoft^
Right-Sute®Uriversal 2021 21.0.02 RSU23828 2021-Jiar071 :16
23
aterstone1780BGR\Lot63BIk1Waterstone1780BGR:np Calc=MJ8 Housefaces: N Page 4
-�- wrightsoft, Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Job: Lot 63 Block 1 Waterston 17...
Date: 06.07.12
By: FLUCH
1
Room name
FAM4IALL(S)
Krr
vdf
24.0 ft
305 ft
3
Room height
96osed
ft heat/eool
9.5 it heat/cool
4
Room dimensions
1.0 x 451.0 ft
1.0 x 290.0 It
5
Room area
451.0 ft2
290.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/ft-fl
(Btutt/tt�
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
4V v:_
16619ad.-, - .----�f-_0049
._0 ,
1.42
... ____
_.259
_.._
30
_ -_30
_43.,1
_
_ 78
_---.__,-,
-
0
m --__--
�_-- -0
_ _---_----
•,--0
'L-GBlk
v dl, stucco ext
2A 2ov
0.201
0.330
n
n
5.83
957
4.06
822
0
0
0
0
0
0
0
0
_._0
40
0
----- _
20
0
116
0
-
81
0
11
11 JO
Blk vlelF stu000 eM '~
_ _ 0.600
0201
_ n_
r e '
17.40
583
17.58
.4.06
_. 0
0
0
0
__ v._. __
0
.._ _ _. _. - 0
6
_._ w_ _ 20
0
_ _._20
0
350
-__ -.0
353,
_ _-_- -_0
2A2ov__..______0.330_ne.
_..__.957._.__]6.61
0
_.__ __:0
_____0
___�_0_.._
____..0
_. .._0___-_-.0
W _
-166 19ad
0049
e
1.42
259
30
30
43
78
0
0
0
_____._..0
0
BIk nell stu000ext
2A
0201
a
683
4.06
128
95
556
387
96
_
96
560
390
2ov ,..;
_,-.0.330
_e`,_
. .._957,
vs .22.43
__.... 33
_ _..w, '_ 2
... _._._ 313
..._..-___ 733
_._.:... _._._0
-._.. _ _ ;0
W
16B-19ad
0049
s
1.42
259
30
30
43
78
0
0
0
0
I--G
Blkvlell sfiicooex< -
10C m
-0.201
0550
,.s _
s
583
15.95
4.06
- 1620
�Y .64
18
•-- 46
18
_-__ _'269
285
-
187
289
" _..,._ __o
0
. _ . __._ -0
0
_ _______ 0
0
- . - -`0
0
2A 2ov
0330
s
957.
'852
0
0
0
, 0
0
0
0
0
W w
16B-19ad,
w_
2.59
30
30
�43
?0.._
- _._
v�
Blkulell'stucaoeM.
_0049
6201
w :
_„142
5.83
-.
- 0
0
.b
.__
_. O.
_O
.O
_-o
'. _._G
2A2ov___ ___.0 ._ _,
_-.o.33o
--w '
____.957:
:._22.43
_..=__ _0
__._ .___.o
.._ __.__.o
___o
._.__...... o
_ o
__ __o
. ___ o
V)/
BIk v di, stucco ext
0201
nw
5.83
4.06
0
0
0
0
0
0
0
._ _
0
-G
2A-2ov
0230
nw
957
16.61
0
0
0
0
0
0
0
0
12C-Osw °
0091
264
131
0
0
0
0
__ - 108
~108
_ 285
142
11D0
Q390
_n.•
1131
_ `---1143
_ ;._ :0
_.... -. 0
_
.._. »:0
0
. 0
:- _u_0
C
16B-30ad
0.032
0.93
1.69
538
538
499
909
346
346
321
584
22A1♦11_ _.__._ _
_..._0989
='
28.68,
,_ _ -.00
- . _451
-._24
6
c) AED excursion
_72
-88
Envelope loss/gain
2780
2744
2506
1462
12
a) Infiltration
727
203
317
89
b) Room ventilation
0
0
0
0
13
Internal gains: Oocepantso 230
2
460
0
0
Appliances/other
01
1200
Subtotal (lines 6to 13)
3507
3407
2823
2750
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
3507
3407
2823
2750
15
Duct loads
13 %
25 %
452
862
13%
25%1
364
696
Total room load
3959
4269
1
1
3187
3446
Air required
168
210
135
169
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
,05A - wr➢g➢�tsoft 2021-Jrur0712:1623
Right-Sute®Uriversal 2021 21.0.02 RSU23828 Page 5
aterstone17808GRIol63BIk1Waterstorel780BGR.nQ Calc=MJ8 Housefaces: N
- wrightsoft° Right-JO Worksheet
Entire House
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
Job: Lot 63 Block 1 Waterston 17...
Date: 06.07.12
By: FLETCH
1
Room name
DIN/FOY
2
Exposed wall
27.7 it
3
Room height
95 It heat/cool
4
5
Room dimensions
Room area
1.0 x 1905 It
190.5 ft2
Ty
Construction
number
U-value
(Btuh/ftz- F)
Or
HTM
(Btuh/ft2)
Area (ftz)
or perimeter (ft)
Load
(Btuh)
Area
or perimeter
Load
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P5
Heat
Cool
6
W
VI/
J6619ad-�__ .. ..__
Blk vdl, stucco eM
2A-2ov
_::._,.__0049
0.201
0230
-
__n,_:
n
n
142
5B3
957
• __2,59.
4.06
822
. 0
72
23
-
0
49
0
:0.w,,,_.__.
283
224
197
193
_.
11
_-
t__.—_G
11J0 .__ .� _
Blk wall; stucco e)d
0600
0201
n_
ne
17.40
5.63
1758
4.06
0
0
17
_ . _0
99
69
W _
W
f—CG
I—C:
2A 2ov___ _ __..._
_166.19ad_
Blkwell stu000ext
2A2ov_._. m.,..._:_
1613-19ad
m
1-2ov_.
___ 0.330
0049
0201
_.-__._0.330
0.049
0201
0550
ne _
e_
a
_,e .;
s
s
s
:S
. _ _ ..957.
1.42
583
_. _-..957
1.42
1525
957
__...16.61,
2.59
406
__.,,22.43
259
162000
., .852
_ ^ __._ 12
0
92
.. __-_,.16
0
0
_ __. _0
76
: _:._...1
0
0
__ ___ .114
441:
_ ..._::..156
0
0
0
—.. _ _ _198
307
366
0
0
__
_
.. _-.._._._
,
.. _ .. ,._.._'.
W _-
_._ _ _.-.
.166-19ady
Blk well, stucco e�
:2A20V_,, ::.- -------
_ . __-0.330
_0.049
0201
�0330_w_...___957___.:22.43
w._
w
142
5.83
_..
259
4 06
M0
- 0
.__----0
0
0
-0
0
D
0
� 0
__0
yJ
L---G
C r
F _ --
Blk wall, stucco ext
2A-2ov
12C'Osw -'
11D0 _.:____..____.
16B 30ad
. _
22A,1p1.- ----__ _. _
0.201
0230
0091
_�__0390
0.032
_ __. 0,989
nw
nw_
_n_.
__
_ w.
5b3
9.57
264
._ 11.31
0.93
_
28.68
4.06
16.61
1`.31
,11,43._
1.69
_
.._._ 0.007-
29
12
0
_`0
_ _. 227
17
0
0
--...-0___-
227
. — _
99
114
0
_ _ 210
4
69
198
0
_ 383
_ � _— 0
_
_--
6
c) AED excursion
-73
Envelope loss/gain
2534
1907
12
a) Infiltration
' 516
144
b) Room ventilation
0
0
13
Internal gains: Occupants@ 230
1
230
Applianceslother
0
Subtotal (lines6 to 13)
3050
2281
Less extemalload
0
0
14
Less transfer
Redistribution
Subtotal
0
0
3050
0
0
2281
15
Duct loads
13 %
25 %
393
577
Total room load
Air required (cdm)
3444
146
2858
141
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-4&wr➢ghtsoft- 2021-1n-0712:1623
Right-SLite@)Uriversal 2021 21.0.02 RSU23828 Page 6
aterstore1780BGR\Lot638Ik1Waterstore1780BGR.rup Calc=MJ8 Housefaces: N
Duct System Summary Job: Lot63 Block 1 Waterston...
- wrightsoft� Date: 06.07.12
Entire House By: FLETCH
DEL -AIR HEATING & AIR CONDITIONING
531 CODISCO WAY, SANFORD, FL 32771 Phone:407-333-2665 Fax:407-333-3853 Web: W W W.DEL-AIR.COM
e-roject intormation
For: ADAMS HOMES
8617 Merano Avenue, Fort Pierce, FL 34951
External static pressure
Pressurelosses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.40
in H2O
0.06
in H2O
0.34
in H2O
0.170 / 0.170
in H2O
0.312
in/100ft
947
cfm
109
Supply Branch Detail Table
Cooling
0.40 in H2O
0.06 in H2O
0.34 in H2O
0.170 / 0.170 in H2O
0.312 in/100ft
947 cfm
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH2
c 111
2
5
0.460
4.0
Ox 0
VI Fx
3.9
70.0
BR2
c 1517
68
75
0.420
6.0
Ox 0
VIFx
11.0
70.0
BR3
h 2332
99
84
0.443
6.0
Ox 0
VIFx
6.7
70.0
DIN/FOY
h 3444
146
141
0.374
7.0
Ox 0
VIFx
20.9
70.0
FAMIHALL(S)
c 4269
168
210
0.434
8.0
Ox 0
VIFx
8.3
70.0
KIT
c 3446
135
169
0.381
7.0
Ox 0
VIFx
19.1
70.0
LAU
c 1138
26
56
0.456
4.0
Ox 0
VI Fx
4.5
70.0
MBATH
h 2349
100
59
0.312
6.0
Ox 0
VI Fx
24.0
85.0
st1
MBR
h 3870
164
123
0.322
7.0
Ox0
VIFx
20.7
85.0
sti
WIc
h 887
38
26
0.333
4.0
Ox 0
MR
17.1
85.0
sti
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
sti
PeakAVF
302
208
0.312
553
10.0
0 x 0
VinlFlx
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat
Trunk
rb2
Ox 0
947
947
0
0
0
0
Ox 0
MFx
wrightsoft-
7.w.,<�„� Rigid-Sute®Uriversal202121.0.02RSU23828
aterstone1780BGR\Lot63BIk1Waterstone1780BGR.np CaIc=MJ8 Housefaoes: N
2021-Jur0712:1623
Page 1
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot 63 Block 1 Waterstone 1780 BGR Builder Name: ADAMS HOMES
Street: 8617 Merano Avenue Permit Office:
City, State, Zip: Fort Pierce , FL , 34951 Permit Number:
Y
Owner: Jurisdiction: 661000
W
Design Location: FL, ST_LUCIE_CO_INTL
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ce4l4nos.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
❑ This checklist
❑ Form R405-2020 report
❑ Input summary checklist that can be used for field verification (usually four pages/may be greater)
❑ Energy Performance Level (EPL) Display Card (one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements (five pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 - one page)
❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402.5
❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed
2020 Duct Leakage Test Report - Performance Method (usually one page)
6/7/2021 12:27:48 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
Duct Leakage Test Report
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661000 Permit #:
Job Information '.
Builder: ADAMS HOMES Community: Lot: 63-1
Address: 8617 Merano Avenue
City: Fort Pierce State: FL Zip: 34951
- Duct' Leakage Test' Results
System 1
cfm25
System 2
cfm25
System 3
cfm25
Sum of others
cfm25
Total of all
cfm25
— 1780 = Qn
Total of all
Total Conditioned
systems
Square Footage
PASS [:]FAI L
Q SPrescriptive';Method cfrri25 (Total) .
To qualify.as,"substantlallylleak,free" Qn Total must be less tiian or
equal.to 0:04 if air handle"r unit is installed. If air handler -unit is;'not
installed, Qn,".Total.rnust be`less than or equal-fo 0 03 This testing
method -meets the requirements in, accordance with Section .R403 3.3..
Is the-airhandler. unit installed during,testing?OYES (So�„ O, NO`(so ,
O Performance/ERI Method, "cfm25 (Out or Total),
-To ;qualify using this method, Qn,must not be greater than the
proposed ,duct leakage Qn ;specified on Form 1`1405=2020 or 4406-2020
Leakage Type selected on'Form On specified on;Form R405-2020
R405 2020 (E'h r9y,Calc) or R406.2020, ; (EnergyCalc): or R406-2020 �
„ m.. .
Proposed Qn 0.05
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes.
Testing Company
Company Name: Phone:
I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the
selected compliance path as stated above, either the Prescriptive Method or Performance Method.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #:
Issuing Authority:
6/7/2021 12:28:53 PM EnergyGauge® USA 7..0.OD - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2020 Florida Building Code, Energy Conservation, 7th Edition
Jurisdiction: 661000
Permit #:
' '-"
b Information 7
Builder: ADAMS HOMES Community: Lot: 63-1
Address: 8617 Merano Avenue
City: Fort Pierce State: FL Zip: 34951
`""-
WLk'9PTbst-flesul Passing bt.',,dithbr'the -P'elflo'r'manc"'e. Prie'sdfioWd,� 6r,"8 06th6
PRESCRIPTIVE ,ME-rH0DJ, h6 bul�iding'."qr.dWe ir leak tested verifiqdf�s; aving an a rate :oi"66f �eicedding 7 air '
-,
.,,4-,.,',
:changes r our -a,Dressure:o n�.Cfimafe26neg�,1-, and 2;�
a
PERFORMANCE or' 'EFWMETHOD ,Thb build— "ifshallf be:fl�ited'ah&48(166 d as,: having.4"fiair-"
YVo,!r1gu9'leakage rate of notaxceeding
--!9Q,-PrL'
:`the selected ACH(50) value, as shown on Form R405 2020 (Performance) or R406 2020'(ERI} section '
labeled aijnfllfriti'n-,sub-*
0 section ACH50
specified R406, 2020 �C416: rf6rmani:;6);6r 7.000
'
x 60 15664 Method for calculating buildinq volume:
CFM(50) Building Volume ACH(50)
0 Retrieved from architectural plans
F-1 PASS Code
0 software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated
L must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
N
Testing Company;;,'
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
6/7/2021 12:28:41 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 8617 Merano Avenue Permit Number:
Fort Pierce , FL , 34951
MANDATORY REQUIREMENTS - See individual code sections for full details.
V
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
❑ R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system,
including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise
sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire
system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn =
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the
compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). If heated water circulation systems are
installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall
❑ be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
6/7/2021 12:28 PM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'% inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 60oC).
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of
combustion types of service water -heating systems to be turned off.
❑ R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
❑ R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TMA, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
❑ R403.6.1 Whole -house mechanical ventilation system fan efficacy.When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole -house mechanical
ventilation, the air handler shall be powered by an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment.
R403.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
❑ on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the
outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other
factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
HRV or ERV
Any
1.2 cfm/watt
Any
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.7.1.1 Cooling equipment capacity. ' Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Florida Building Code, Energy Conservation —Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -Fred heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
QR403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
❑ R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (Mandatory). The energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
F1 R403.13 Dehumidifiers (Mandatory If installed, a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential.
R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy of not less than 65 lumens -per -watt.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
6/7/2021 12:28 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
LEGAL DESCRIPTION:
(Supplied by Client)
LOT 63 IN BLOCK 1, WATERSTONE PHASE 1,
ACCORDING TO -'THE PLAT THEREOF AS
RECORDED IN PLAT BOOK 52, PAGES 35
THROUGH 47, OF THE, PUBLIC RECORDS OF
ST. LUCIE COUNTY, FLORIDA.
ABBREVIATIONS:
E/EP�5dTH
LL4CAMKD S53
FD = FOUND 5/8 IRON REBAR
,RIGHT OF WAY
= MEASURED
P = PLATTED
ICISu TUAUOFCRVE
L � LENGTH OF CURVE
D=•DELTA OF CURVE
FFE = FINISHED FLOOR LEVVATION
OH -OH -OH- = OVERHEAD �yIRES
2 X-X- = CHAT LINK FE CE
PLAS IC
0-0-0-= WOOD FENCENC
CONIC. = CONCRETE
C.P.= CONCRETE PAD
Cov.= COVERED
® #ER ® POUR ®BOXC7RIC 0 CLEAN
8VE I® �kLTEl El BOX
SURVEYORS NOTES:
1, oNLESS OTHEROSE NOTED ONLY PLATTED EASEMENTS ARE SHOA
HEREON.
2. ALL LOT DIMENSIONS SHOWN ARE PER PLAT UNLESS OTHER SHOWN.
3. NO UNDERGROUND UTILITIES OR IMPROVEMENTS MERE LOCATED UNLESS
OTHERWISE SHOWN,
4., THIS SITE LIES WITHIN FLOOD INSURANCE RATE MAP ZONE X MAP#
12111CO070 J DATED: 2-16-12,
5. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR
AND IS PROVIDED AS A COURTESY. THE FLOOD ZONE SHOULD BE VERIFIED
BY A DETERMINATION AGENCY.+
6. BEARINGS SHOWN HEREON ARE BASED ON THE EAST LINE OF
LOT 63 AS BEING ASSUMED TO BEAR N0647'55"E.
7. U.E. DENOTES UTILITY EASEMENT. D.E. DENOTES DRAINAGE EASEMENT,
8. THE ACCURACY OF THIS SURVEY IS PREMISED ON THE EXPECTED USE OF
THE SURVEY. THE EXPECTED USE / PURPOSE OF THIS SURVEY IS HOME
CONSTRUCTION. ACCURACY=1 FOOT IN 7.500 FEET OR BETTER;
9. ADDITIONS OR DELETIONS TO THIS SURVEY MAP BY ANYONE OTHER THAN
THE SIGNING SURVEYOR IS PROHIBITED WITHOUT WRITTEN CONSENT.
r DRAINAGE PROPOSED x.0 =EXISTING ELEVATION
= PROPOSED ELEVATION
AN
i(OuBjEdT To ROP O S E TH DPLOTr UILmdDEPT. APPROVAL)
ALL ELEVATIONS SHOIf yN HEREON ARE BASED ON
NORTH AMERICAN VERTICAL DATUM OF 1988(N.A.V.D.'88)
50' RIW - 20'
FD DISKj� BE MEpRANO
"LB 5610' i -MQ39 N.EL T,, oRTM RIM
A.Maf -88
Et I
460 83'12'05"
PARCEL L-2
(LAKE)
8617 MERANO AVENUE
SCALE:1 °=30,
Atlantic Land Designs
of the Treasure Coast, LB7468
764 NE Jensen Beach Blvd. Jensen Beach, FL 34957
Mailing Address:
P.O. Box 1421 Jensen Beach, FL 34958
ALD5543@gmail.com (772) 398-4290
DATE: 6-2121
DRAWN: LW\JC
2021-0619
7 21-21
PLOT PLAN
LAST FIELD DATE:6-16-21
ASPHALT ROAD
AVENUE
, 529.61' FDR NAIL DISK
-0 L`•, 5610"
MIN. SECK REQ,
FRONT
CNR
ZNG
62.60' p
!r t i t i ed to: Adams Homes
Inc.
I hereby certify that the survey sho*n hereon is true and correct
and Is based on actual meoseurements taken In the field.
IIM CASs
L�RSiFJ C,gTF o
PSM 5543
i Digitally4gned byJamnACeairoJr. 1
Jam A.Ce iroL.m°�Iqm° P
DaIe202W72315:1132.01= L1 SFATE OF T
NOT VALID HOUT ANAUTHENTICATED ELECTRONIC °'L0RIILI DP +r
SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL BF� SURVEYOR
1
I