HomeMy WebLinkAboutEnergy Efficient Certificatesection #, Insu„ l_ationilnspection &.Re ID Plans Verified Value Feld Ver Valtie Clie? Comments/A' s` .. sumpto s ,All installed insulation is labeled r $ t �i ,j ,� ❑Complies ;Requirement will be meta ,',or the installed R-values :T❑Does Not { provided. 3 0Not Observable X�❑N t Applicable ; 402.1.1, Mall insulation R-value. If this is a, R- R- ElComplies ;See the Envelope Assemblies 402.2.4, } mass wall with at least 1/2 of the � 1�lood ; ❑ Wood ❑Does Not I table for values. 402.2.5 !wall insulation on the wall insulation Mass ❑ Mass '❑Not Observable [IN3]1 exterior, the exterior I , requirement applies. ; ❑Steel , ❑Steel s❑Not Applicable ; 303.2 ;Wall insulation is installed per l�,rx r, y` .: r �'+ ` ° ❑Complies ;Requirement will be met. ,I❑Does [IN413 manufacturer's instructions. ) .' Not ]❑Not Observable ' 1❑Not Applicable Additional Comments/Assumptions: 1 1 High Impact (Tier 1) 2 Medium Impact (Tier 2)13 I Low Impact (Tier 3) Project Title: Remodel For M%M Mark Fick Residence Report date: 08/20/21 Data filename: HARichard Atwood\2021\Remodel for M and M mark Fick Resdince\Mark Fick Paae 6 of 8 #; Final Inspection Provisions„ Plans Uer�fi®d Value Fietd,Ver�fietl ' Comphe ? Comments/A§sum'ptions.. &Re .ID ... Value- 402.1.1, ►Ceiling insulation R-value. Where ; R- R- :❑Complies ',See the Envelope Assemblies 402.2.1, > R-30 is required, R-30 can be a Wood Wood ;❑Does Not table for values. 402.2.2 used if insulation is not Steel Steel I❑Not Observable [Fill' ;compressed at eaves. R-30 may ; ; : , i be used for 500 ft2 or 20% ;❑Not Applicable ; 1(whichever'is less) where I ►sufficient space is not available. 303.1.1.1„Ceiling insulation installed per 4y E]Complies ;Requirement will be met. 303.2 Imanufacturer's instructions. `"Y +,�:'r< r r`Kn �'��'atif❑Does Not [FI211 ; Blown insulation marked everya� ! 300 ft-. (� r' xt>❑Not Observable ; ' ,,,�,:• p . . , , ;s; ti's r ❑Not Applicable ; 402.2.3 ;Attic access hatch and door ; R- R- :❑Complies ;Requirement will be met. [FI31' i insulation z R-value of the s ;❑Does Not adjacent assembly. ;❑Not Observable ; ❑Not Applicable 402.4.2, ;Building envelope tightness ; ACH 50 = ACH 50 = ;❑Complies ;Requirement will be met. 402.4.2.1 i verified by blower door test result: T]Does Not [FI17]' of <7 ACH at 50 Pa. This ' '❑Not Observable 1 !requirement may instead be met ; , ;via visual inspection, in which ; :❑Not Applicable ; !case verification may need to ! ;occur during Insulation.' Inspection. ! ! ! ! 403.2.2 ;Post construction duct tightness ; cfm cfm ;❑Complies ;Exception: All ducts and air [FI4]' test result of s8 cfm to outdoors, ;❑Does Not s'handlers are located within `or 512 cfm across systems. Or, I conditioned space. ! ;❑Not ;rough -in test result of s6 cfm- Observable !across systems or s4 cfm ! ! ;❑Not Applicable ; without air handler. Rough -in test ;verification may need to occur .during Framing Inspection. 4031 `1 j P' ❑Complies Programmable thermostats ,Requirement will be met. [FI9]z ' installed on forced air furnaces. + 3❑ ! Does Not Q3❑Not v , Observable ; ❑Not Applicable ; 403 1'.2,.Heat pump thermostat installed ; ,4 ;1❑Complies ;Requirement will be met. [FI10]2 ,.,on heat pumps. ti j❑Does Not []Not Observable ; ?❑Not a A Applicable PP , , 403 4; Circulating service hot water�t'❑Complies :Exception: Requirement is [Fillf systems have automatic or ' `;� ,§, 3�� �.d�d� �� ,+}❑Does Not not applicable. 'laccessible manual controls. j �[jNot Observable ; ❑Not Applicable 404.E ! 50% of lamps in permanent ` �� ` � � ,;,�,� �� " �'x?�} ". ��, ,�` �_ 0Complies ',Requirement will be met. P ���� [FI6] tfixtures are high efficacy lamps. z s 0Does Not ; ` j r g a z t Observable 7❑Not % J❑Not Applicable �_ �.,,;� .,.r,.. . r, PP , ;Compliance certificate posted. ° N ;z , 3 ,:= rry❑Complies ,Requirement will be met. 1' v 'I❑Does Not ❑ Not Observable ❑Not Applicable , 303 3 ;Manufacturer manuals for �, ,y❑Complies ;Requirement will be met. [FI1813: ° mechanical and water heating l � '`"r � <,� � ; ; } * �, ,:;,� 4 ❑Does Not I equipment have been provided. J 4 rr $ t ti ; ' I r ❑Not Observable . a , ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 ° Medium Impact (Tier 2) 3:! Low Impact (Tier 3) Project Title: Remodel For M/M Mark Fick Residence Report date: 08/20/21 Data filename: HARichard Atwood\2021\Remodel for M and M mark Fick Resdince\Mark Fick Paoe 7.of 8 20091I CC Energy ffllency Certificte Above -Grade Wall 16.00 Below -Grade Wall 0.00 Floor 0.96 Ceiling ! Roof 0.00 Ductwork (unconditioned spaces): Window 0.30 0.25 Door 0.30 0.25 .: .. Air Source 0 HSPF, 0 Air Source 0 HSPF, 0 Air Source 0 HSPF, 0 Air Source .0 HSPF, 0 Air Source 0 HSPF, 0 Water Heater: Name: Date: Comments