Loading...
HomeMy WebLinkAboutRevisions File COPY OFFICE USE ONLY: DATE FILED: ��- PERMIT# 2101-0333 REVISION FEE: RECEIPT# PLANNING & DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE,FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONSECENED PROJECT INFORMATION WoV 2 3 2021 LOCATION/SITE St.Lucie CounW ADDRESS: Permitting 5313 SOUTH 25TH ST DETAILED DESCRIPTION OF PROJECT REVISIONS: CHANGE OF A/C SUBCONTRACTOR-ATTACHED IS NEW ENERGY CODES,DUCK DRAWINGS,MANUAL J CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CBC 1263072 ST. LUCIE CO CERT. #: 31220 BUSINESS NAME: PORT ST LUCIE PROPERTIES,INC. QUALIFIERS NAME: MARK MONTALTO ADDRESS: 201 SW PSL BLVD SUITE 103 CITY: PORT ST LUCIE STATE: FL ZIP: 34984 PHONE (DAYTIME): 772-336-0050 FAX: OWNER/BUILDER INFORMATION: NAME: MARK MONTALTO ADDRESS:201 SW PSL BLVD SUITE 103 CITY: PORT ST LUCIE STATE: FL ZIP: 34984 PHONE (DAYTIME: 772-336-005o FAX: ARCHITECT/ENGINEER INFORMATION: NAME: PAUL WELCH JR ADDRESS: 1984 SW BITMORE ST CITY: PORT ST LUCIE STATE: FL ZIP: 34984 PHONE(DAYTIME): 772-785-9888 ppn� FAX: SLCCC. 9/23/09 S� Q°` Revised 06130/17 fr ! t ff r _ N �. File Cnry M21 p f-J333 EVIEWED FOR REVISION CODE COMPLIANCE ST. L CIE COUNTY B®CC Ir�3d/24 E F L'rYPGAL-WALL SKMN 5 �� M. m tam M9noum W a a -- i p L3 11 p x0 m.tip Job#: 1282 Air Caics, LLC Scale: 1 :243 Performed by Vicki Lynne Nisa for: Page 1 Thomas Residence 7550 Hidden Hammock Ln Right-Suite@ Universal 2021 5313 S 25th St Vero Beach, FL 32966 21.0.08 RSU27054 Fort Pierce,FL 34981 Phone:772.800.8413 2021-Nov-11 13:34:29 vickilynne@aircalcs.com •..25th St Thomas Res PSL Prop.rup FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include: i ❑ This Checklist ❑ A FORM 405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool,name of individual completing the compliance report(one page). ❑ An input summary checklist that can be used for field verification(usually 4 pages/may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements(five pages) Required prior to CO for the Performance method: ❑ Air Barrier and Insulation inspection Component Criteria checklist(Table 402.4.1.1-one page) i ❑ A completed Form 2017 Envelope Leakage Test Report(usually one page). Section R402.4 or R402.4.1.2 exceptions may apply. i I ❑ if FORM R405 duct leakage type indicates anything other than "default leakage", then a completed FORM R405 Duct Leakage Test Report(usually one page). i Fie CoPv �� 2l01�333 EVsD FOR CODE COMPLIANCE STo L CIE COUNTY "" EVI 1 """ N SCCC 1113dlZ,f %wo 2021-Nov-11 13:37:12 -�Wr htSofr Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section405A.1 CompliantSoflware Page 1 9 .r -.of HVAC15313 S 25th St Thomas Res PSL Prop.rup Calc-MJ8 Front Door faces: N I 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: Thomas Residence Builder Name: PSL Prop Street: 5313 S 25th St Permit Office: City,State,Zip: Fort Pierce,FL 34981 Permit Number: Owner: Thomas Residence Jurisdiction: St Lucie Design Location: FL,St Lucie Co Intl County: St Lucie(Florida Climate Zone 2) 1.New construction or existing New(From Plans) 9. Wall types (1851 ft2) Insulation(R) Area(W) I 2.Single family or multiple family Single-Family a. Bfk Wall,Stucco Ext,R-4.1 Ext 4.1 1611.21 b. Frm Wall,1/2"Gyp.Bd Ext,R-11 11.0 239.95 3.Number of units,if multiple family 1 c. NIA 4.Number of bedrooms 3 d. WA 5.Is this a worst case? Yes 10. Ceiling types (1766 f?) Insulation(R) Area(W) a. Attic,Shngl Roof,R-30 Cell Ins 30.0 1765.75 6.Conditioned floor area above grade(flI 1765.75 b. NIA Conditioned floor area below grade(ft2) 0 c. NIA 7. Windows 336 ft2 Description Area ft2 11•Ducsu:House Attic,Rat:House Attic,AH:Uncond Garage R Area 50.25) ( ) P ( ) a. r 6.0 450.25 a.U-Factor: Sgi Impact,0.580 217.97 b• SHGC: 0.24 b.U-Factor. Sg)Impact,0.650 117.81 12.Cooling systems kBtulhr Efficiency SHGC: 0.21 a.Spiit air conditioner 42.0 SEER:16.0 c.U-Factor: b• SHGC: 13.Heating systems kBtulhr Efficiency d.U-Factor: a.Electrfc strip 27.6 AFUE:100.0 SHGC: b. Area Weighted Average Overhang Depth: 6.339 ft 14.Hot water systems Area Weighted Average SHGC: 0.229 a.Electric conventional(40 gal) Cap:40 gal EF:0.96 8. Floor types(1765.75 W) Insulation(R) Area(JI b.Conservation features a. On Grade Depth,Tile Fir Fnsh 0.0 1765.76 (None) b. N/A c. NIA 15.Credits None ! Glass/Floor area: 0.190 Total Proposed Modified Loads: 56.37 PASS Total Baseline Loads: 57.47 1 hereby certify that the plans and specifications covered by Review of the plans and specifications gtiEST� this calculation are in compliance with the Florida Energy covered by this calculation indicates tipt 1t0 Code. compliance with the Florida Energy J Code.Before construction is completed, �i�' ' t� jgr,"" PREPARED BY: 114�4 zV"L1& this building will be inspected for 11/1 1/2021 compliance with Section 553.908 DATE: � Florida Statutes. I hereby certify that this building,as de . ne s in compliance with the Florida E g ode OWNER/AGENT: BUILDING OFFICIAL: DATE: II •I� DATE: -Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance-requires an Air Barrier and insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2).. ,10 it oo�,�t�! Sti Petm`,���9 2021-Nov-11 13:37:12 wrighttslaft9 Right-3ulte®Universal 2021 21.0.08 RSU27054 Rig ht-Energy®Florida 2017 Section 405A.1 Compliant Sotlware Page 2 kutm ,u,;s,•.gc,q oft HVACIS313 S 251h St Thomas Res PSL Prop.rup Cale=MJa Front Door faces: N FORM R40572017 Building Input Summary Report PROJECT Title: Thomas Residence Bedrooms: 3 Address type: Street address Building Type: FLAsBuilt Bathrooms: 2 Lot#: Owner: Thomas Residence Conditioned Area: 1766 Block/Subdivision: #of Units: 1 Total Stories: 1 Platbook: Builder Name: PSL Prop Worst Case: Yes Street: 5313 S 25th St Permit Office: Rotate Angle: 0 County: St Lucie Jurisdiction: St Lucie Cross Ventilation: No City,State,Zip: Fort Pierce,FL 34981 FamilyY Type: Single-Family Whole House Fan: No Newlisting: New(From Plans) Terrain: Ocean/Lake Year Construct: Shielding: Suburban Comment: CLIMATE IECC Design Temp. Int Design Temp Heating Design Daily Temp ✓. Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,St.Lucie Co Intl FL_Fort_Plerce 2 41 90 70 75 486 57 Low BLOCKS # Name Area Volume 1 House 1765.75 f12 16274.03 fN SPACES # Area Volume Kitchen Occupants Bedrooms infti ID Finished Cooled Heated 1 Bed 2 16125 ft2 1306.13 ft2 No 0 1 1 Yes Yes Yes 2 Bath 2 54.00 1`12 437.40 f? No 0 0 1 Yes Yes Yes 3 Lin 6.25 ft2 50.63 ft2 No 0 0 1 Yes Yes Yes 4 Hall 29.75 ft2 240.98 fie No 0 0 1 Yes Yes Yes 5 Bed 3 172.50 ft2 1397.25 fP No 0 1 1 Yes Yes Yes 6 Family Room 185.00 ft2 1868.50 ft3 No 1 0 1 Yes Yes Yes 7 Kitchen/Nook 214.50 fl2 2166.45 f? Yes 2 0 1 Yes Yes Yes 8 Living Room 265.50 ft2 2681.55 fl' No 1 0 1 Yes Yes Yes 9 Laundry 77.00 f? 623.70 f? No 0 0 1 Yes Yes Yes 10 Dining Room 108.00 ft2 1090.80 fN No 0 0 1 Yes Yes Yes 11 Foyer 72.00 ft2 727.20 ft2 No 0 0 1 Yes Yes Yes 12 Wtr Gist 28.00 ft2 226.80 fP No 0 0 1 Yes Yes Yes i 13 Linen 5.26 ft2 42.53 fN No 0 0 1 Yes Yes Yes 14 WIC 41.50 ft2 336.15 ft' No 0 0 1 Yes Yes Yes 15 Master Bath 128.75 ft2 1042.88 fN No 0 0 1 Yes Yes Yes 16 Master Bedroom 216.50 ft2 2035.10 f? No 0 1 1 Yes Yes Yes FLOORS (Total Exposed Area=1766 sci t.) # Floor Type Space Perimeter R-Value Area U-Factor Tile Wood Car pet I 1 On Grade Depth,Tile Fir Fnsh Bed 2 29 ft 0 16125 ft2 0.989 1.0 0 0 2 On Grade Depth,Tile Fir Fnsh Bath 2 6 ft 0 54.00 ft2 0.989 1.0 0 0 3 On Grade Depth,Tile Fir Fnsh Lin 0 ft 0 625 ft2 0.989 1.0 0 0 I 4 On Grade Depth,Tile Fir Fnsh Hall 0 ft 0 29.75 fl2 0.989 1.0 0 0 5 On Grade Depth,Tile Fir Fnsh Bed 3 28 ft 0 172.50 ft2 0.989 1.0 0 0 6 On Grade Depth,Tile Fir Fnsh Family Room 25 ft 0 185.00 ft2 0.989 1.0 0 0 7 On Grade Depth,Tile Fir Fnsh Kitchen/Nook 11 ft 0 214.50 fie 0.989 1.0 0 0 8 On Grade Depth,Tile Fir Fnsh Living Room 8 ft 0 265.50 ft2 0.989 1.0 0 0 9 On Grade Depth,Tile Fir Fnsh Laundry 14 ft 0 77.00 ft2 0.989 1.0 0 0 10 On Grade Depth,Tile Fir Fnsh Dining Room 13 ft 0 108.00 ft2 0.989 1.0 0 0 11 On Grade Depth,Tile Fir Fnsh Foyer 8 ft 0 72.00 if 0.989 1.0 0 0 12 On Grade Depth,Tile Fir Fnsh Wtr Gist. 12 ft 0 28.00 ft2 0.989 1.0 0 0 13 On Grade Depth,Tie Fir Fnsh Linen 2 ft 0 5.25 ft2 0.989 1.0 0 0 14 On Grade Depth,Tile Fir Fnsh WIC 7 ft 0 41.50 ft2 0.989 1.0 0 0 15 On Grade Depth,Tile Fir Fnsh Master Bath 14 it 0 128.75 fl2 0.989 1.0 0 0 16 On Grade Depth,Tile Fir Fnsh Master Bedroom 33 it 0 216.50 ft2 0.989 1.0 0 0 I! ROOF Roof Gable Roof Solar SA Emitt Emilt Deck Pitch ✓ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip RoofAsph 1974 fj2 Medium 0.75 No 0.90 No 0 27 2 Hip RoofAsph 471 ft Medium 0.75 No 0.90 No 0 27 Right-Suite®Universal 2021 21.0.08 RSU27054 Rl ht-Ener O Flodda 2017 Section 405.4.1 Com Gant Software Nov-11 13:37:12 wrightsotlt� 9 9Y P Page 3 A4nrrs=tfa�hsgc q ...oil HVAC15313 S 251h St Thomas Res PSL Prop.rup Cale-M.18 Front Door faces: N FORM R405-2017 ATTIC # Tye Ventilation Vent Ratio 1 in Area RBS IRCC 1 Full attic Vented 150 1766.75 ft2 N N 2 Full attic Vented 150 421.00 fF N N CEILING (Total Exposed Area=1766 sq.ft.) # Ceiling Type Space R-Value U-Factor Area Framing Fraction Truss Type 1 Attic,Shngl Roof R-30 Cell Ins,1! Bed 2 30 0.034 161.25 ft2 0.10 Wood 2 Attic,Shngi Roof R-30 Cell Ins,1/ Bath 2 30 0.034 54.00 fl2 0.10 Woad 3 Attic,Shngl Roof,R-30 Cell Ins,1/ Lin 30 0.034 6.25 ft2 0.10 Wood 4 Attic,Shngl Roof,R-30 Cell Ins, I Hail 30 0.034 29.75 ft2 0.10 Wood 5 Attic,Shngl Roof,R-30 Cell Ins,1/ Bed 3 30 0.034 172.50 ft2 0.10 Wood 6 Attic,Shng!Roof R-30 Cell Ins,1/ Family Room 30 0.034 185.00 ft2 0.10 Wood 7 Attic,Shngl Roof R-30 Ceil Ins,1/ Kitcheh/Nook 30 0.034 214.50 ft2 0.10 Wood 8 Attic,Shngl Roof,R-30 Ceil Ins,1/ Living Room 30 0.034 265.50 ft2 0.10 Wood 9 Attic,Shngl Roof,R-30 Ceil Ins,1/ Laundry 30 0.034 77.00 W 0.10 Wood 10 Attic,Shngl Roof,R-30 Ceil Ins,1/ Dining Room 30 0.034 108.00 ft2 0.10 Wood 11 Attic,Shngl Roof R-30 Cell Ins,1/ Foyer 30 0.034 72.00 ft2 0.10 Wood 12 Attic,Shngl Roor,R-30 Cell Ins,'/ Wtr Cist 30 0.034 28.00 fe 0.10 Wood 13 Attic,Shngl Roof,R-30 Cell Ins,1/ Linen 30 0.034 5.25 ft2 0.10 Wood 14 Attic,Shngl Roof,R-30 Cell Ins,1/ WIC 30 0.034 41.50 ft2 0.10 Wood 15 Attic,Shngl Roof,R-30,Cell Ins,1/ Master Bath 30 0.034 128.75 ft2 0.10 Wood 16 Attic,Shngl Roof,R-30 Ceil Ins,1/Master Bedroom 30 0.034 216.50 ft2 0.10 Wood WALLS (Total Exposed Area=1851 sq.ft.) Adjacent Cavity Width Height Sheathing U- Frm. Solar Below# Ornt To Wail Type Space R-Value Ft In Ft In Area R-Value Factor Frac. Absor. Grade% 1 NE Exterior Bik Wall,Stucco Bed 2 0 14 0 8 1 113.4 ft2 4 0.109 0.22 0.60 0 2 - Partition Frm Wall,1/2"Gy Bed 2 11 15 0 8 1 121.5 ft2 0 0.101 0.26 0.60 0 3 NE Exterior Blk Wall,Stucco Bath 2 0 6 0 8 1 48.6 ft2 4 0.109 0.22 0.60 0 5 NW Exterior Blk Wall,Stucco Bed 3 0 12 6 8 1 1d1 3 ft2 4 0.109 0 22 0.60 0 6 SW Exterior Blk Wall,Stucco Family Room 0 10 0 10 1 101.0 W 4 0.109 0.22 0.60 0 7 NW Exterior Blk Wall,Stucco Family Room 0 14 12 10 1 151.6 ft2 4 0.109 0.22 0.60 0 8 SW Exterior Blk Wall,Stucco Kitchen/Nook 0 6 0 10 1 60.6 ft2 4 0.109 0.22 0.60 0 9 NW Exterior Blk Wail,Stucco Kitchen/Nook 0 4 6 10 1 45.6 ft2 4 0.109 0.22 0.60 0 10 NW Exterior Blk Wall,Stucco Living Room 0 7 6 10 1 75.8 ft2 4 0.109 0.22 0.60 0 11 - Partition Frm Wall,1/2"Gy Laundry 11 14 0 8 1 113.4 f12 0 0.101 0.25 0.60 0 12 SE Exterior Blk Wall,Stucco Dining Room 0 12 0 10 1 121.2 ft2 4 0.109 0.22 0.60 0 13 - Partition Frm Wall,12"Gy Dining Room 11 0 6 10 1 5.1 1`0 0 0.101 0.25 0.60 0 14 SE Exterior Blk Wall,Stucco Foyer 0 7 12 10 1 80.8 ft2 4 0.109 0.22 0.60 0 15 SE Exterior Blk Wall,Stucco Wtr Clst 0 3 6 8 1 28.4 ft2 4 0.109 0.22 0.60 0 16 SW Exterior Blk Wall,Stucco Wtr Cist 0 8 0 8 1 64.8 ft2 4 0.109 0.22 0.60 0 17 SW Exterior Blk Wall,Stucco Linen 0 1 5 8 1 12.2 ft2 4 0.109 0.22 0.60 0 18 SW Exterior Blk Wall,Stucco WIC 0 7 0 8 1 56.7 ft2 4 0.109 0.22 0.60 0 19 NE Exterior Blk Wall,Stucco Master Bath 0 4 5 8 1 36.5 ft2 4 0.109 0.22 0.60 0 20 SE Exterior Blk Wall,Stucco Master Bath 0 9 6 8 1 77.0 ft2 4 0.109 0.22 0.60 0 21 N Exterior Blk Wall,Stucco Master Bedroom 0 8 6 9 5 79.8 ft2 4 0.109 0.22 0.60 0 22 SW Exterior Blk Wall,Stucco Master Bedroom 0 18 0 9 5 169.2 ft2 4 0.109 0.22 0.60 0 23 NW Exterior Blk Wall,Stucco Master Bedroom 0 7 0 9 5 65.8 ft2 4 0.109 0.22 0.60 0 DOORS (Total Exposed Area=40 sq.ft.) ✓ # Omt Door T e Space Storms U-Value Width Height Area YP P Ft In Ft In 1 SE Fbrgis Door Foyer None 0.127 6 0 6 8 40.2 W WINDOWS (Total Exposed Area=336 sq.ft.) Wall Overhang Interior # Ornt ID Frame Panes NFRC U-Factor SHGC Impact Area Depth Separation Shade Screening 1 NE 1 Metal Single Clear Yes 0.580 0.24 Yes 15.6ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 2 NE 3 Metal Single Clear Yes 0.580 0.24 Yes 4.8f12 1 ft 0 in 1 ft 0 in None None 3 NW 5 Metal Single Clear Yes 0.580 0.24 Yes 15,6ft2 1 lit 0 in 3 ft 0 in Blinds 45' outdoor 4 SW 6 Metal Single Clear Yes 0.650 0.21 Yes 39.6112 1 ft 0 in 3 ft 0 in Blinds 45' outdoor 5 NW 7 Metal Single Clear Yes 0.580 0.24 Yes 31.2ft2 1 ft 0 in 3 ft 0 in Blinds 45' outdoor 6 SW 8 Metal Single Clear Yes 0.580 0.24 Yes 15.61[12 20 ft 0 in 3 ft 0 in Blinds 45' outdoor 7 NW 9 Metal Single Clear Yes 0.580 0.24 Yes 15.61`12 10 ft 0 in 3 ft 0 in Blinds 45' outdoor 8 NW 10 Metal Single Ciear Yes 0.650 0.21 Yes 39.6ft2 16 ft 0 in 3 ft 0 in Blinds 45' outdoor 9 SE 12 Metal Single Clear Yes 0.580 0.24 Yes 40.8fF 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 10 SE 14 Metal Single Clear Yes 0.580 0.24 Yes 9.6112 6 ft 7 in 1 It 0 in None None 11 SW 16 Metal Singe( inte ) Yes 0.580 0.24 Yes 6.0W 1 ft 0 in 1 ft 0 in None None 12 SE 20 Metal Single(Clear) Yes 0.580 0.24 Yes 9.0ft2 1 ft 0 in 1 ft 0 in Blinds 45' outdoor 13 N 21 Metal Single(((Ciear))) Yes 0.650 0.21 Yes 38.5ft2 14 ft 0 in 3 ft 0 in Blinds 45' outdoor 4 SW 22 Metal Single Clear Yes 0.580 0.24 Yes 31.2ft2 1.ft 0 in 1 ft 0 in Blinds 45' outdoor 15 NW 23 Metal Single Clear Yes 0.580 0.24 Yes 23.Oft2 10 ft 0 in 3 ft 0 in Blinds 45' outdoor 2021-Nov 11 13:37:12 wrightsofV Right-SultelD Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 4 avt riy it oft HVAC15313 8 25th St Thomas Res PSL Prop.rup Cato=MJ8 Front Door faces: N GARAGE ✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 421 ft2 421 ft2 60 ft 8 ft 5 INFILTRATION # Scope Method SLA C M 50 ELA EqLA ACHCH 5 1 Wholehouse Simplified 0.000411 1899 104.4 196.1 0.53 7.00 HEATING SYSTEM ✓ # System Type Subtype Efficiency Capacity Block Ducts 1 Electric strip AFUE:100.0 27.6 kBtu/hr 1 s s#1 COOLING SYSTEM ✓ # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Split air conditioner SEER:16.0 42.0 kBtu/hr 1400 cfm 0.70 1 s s#1 I HOT WATER SYSTEM ✓ # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric conventional 0.96 40 gal 60 gal 120°F None DUCTS Supply -------- --- Return------ Air CFM 25 Percent HVAC# ✓ # Location R-Value Area Location Area Leakage Type Handler Out Leakage QN RLF Heat Cool 1 House Attic 6.0 450 ft2 House Attic 227 fl2 Defsull Leakage Uncond Garage (Default) 6.00 1 1 TEMPERATURES Programmable Thermostat: Y Ceiling Fans: Cooling [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun ( X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Heating [ X ]Jan [ X] Feb [ X Mar [ X Apr [ X May [ X] Jun [ X] Jul [ X] Aug [ X] Sep X] Oct [ X] Nov [ X] Dec Venting X ]Jan I X] Feb I X1 Mar [ X Apr [ X May [ X] Jun X Jul I X1 Aug [ X1 Sep X Oct X I Nov X] Dec Thermostat Schedule: Florida Building Code,6th Edition Hours Schedule Type 20 7 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 j PM 72 72 72 72 72 72 72 72 72 72 72 72 i I wr>Ightsofts Right-Suite®Universal 202121.0.08 RSU27054 Right-Energy®Florida2017 Section 405A.1 Compliant Software Nov111 Page 5 ...oft WACX5313 S 25th St Thomas Res PSL Prop.rup Cale=MJ8 Front Door faces: N FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX= 98 The lower the EnergyPerformance Index,the more efficient the home. 1.New home or addition 1. New(From Plans) 12.Ducts,location&insulation level a.Supply ducts: R 6.0 2.Single-family or multiple-family 2. Single-Family b. Return ducts: R 6.0 c.AHU location: Uncond Garage 3.Number of units, if multiple-family 3. 1 13.Cooling systems Capacity 42.0 4.Number of bedrooms 4. 3 a.Split system: SEER 16.00 b.Single package: SEER 5. Is this a worst case?(yes/no) 5. Yes c.Ground/water source: SEER/COP d. Room unit/PTAC: EER 6.Conditioned floor area(ft� 6. 1765.75 e.Other: 7.Windows,type and area* 14. Heating systems Capacity 27.6 a.U-Factor: Sg7�rripact(AvR). 0.605 a.Split system heat pump: HSPF b.Solar Heat Gain Coefficient(SHGC): 7b. 0.23 b.Single package heat pump: HSPF c.Area(ftz) 7c. 336 c. Electric resistance: COP 100.00 d.Gas furnace,natural gas: AFUE 8.Skylights e.Gas furnace,LPG: AFUE a.U-Factor: 8a. f.Other: b.Solar Heat Gain Coefficient(SHGC): 8b. 15.Water heating systems 9.Floor type,insulation level a.Electric resistance: EF 0.960 a.Slab-on-grade(R-value): 9a. 0.0 b.Gas fired,natrual gas: EF b.Wood,raised(R-value): 9b. c.Gas fired,LPG: EF c.Concrete,raised(R-value) 9c. d.Solar system with tank: EF e.Dedicated heat pump with tank: EF 10 Wall type and insulation: f. Heat recovery unit: HeatRec% a.Exterior: g. Other: 1.Wood frame(Insulation R-value): 10a1. 2.Masonry(Insulation R-value): 10a2. 4 16.HVAC credits claimed(Performance Method) a.Ceiling fans: 9 b.Adjacent: Insulation R-v 1.Wood frame( : 10b1. 11 b.Cross ventilation: alue) 2.Masonry(Insulation R-value): 10b2. c.Whole hous e fan: d.Multizone cooling credit: 11.Ceiling type and insulation level e.Multizone heating credit: a.Under attic(R-value): 11a. 30.0 f. Programmable thermostat: Yes i b.Single assembly(R-value): 11 b. c.Knee walls/skylight walls(R-value) 11 c. d.Radiant barrier installed 11d. *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. i certify that this home has complied with the Florida Building Code,Energy Conservation,through the above energy saving features I which will be installed(or exceeded)in this hom before fin I inspection. Otherwise,a new EPL Display Card will be completed based on installed Code compliant fe s. Builder Signature: Date: / � -/ '' Zl Address of New Home: 5313 S 25th St City/FL Zip: Fort Pierce,FL 34981 1 i I 2021-Nov-11 13:37:12 +Wr19htSofte Rig ht-Suile®Universal 2021 21.0.08 RSU27054 Right-Energy®Florlda 2017 Section 405.4.1 compliant Software Page 6 OR WAC15313 S 25th St Thomas Res PSL Pmp.rup Caic=MJ8 Front Door faces: N 1 i i FORM R405-2017 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 5313 S 25th St PERMIT#: Fort Pierce, FL 34981 MANDATORY REQUIREMENTS -See individual code sections forfull details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. rl R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The seating methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones i and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statutes or Individuals licensed as set forth In Section 489.105(3)(fj (g);or(1)or an approved third party. A written report off the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception:Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended I weatherstripping or other infiltration control measures. 2.Dampers including exhaust,Intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if Installed at the time of the test,shall be fully open. rl R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127,the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per sqGuare foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/1.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. i Wtt79ilt5Oft4 Rig ht-Suile®Universa12021 21.0.08 RSU27054 Rig ht-Energy®Florida2017 Section405A.1 Compliant Soft 2021-Nov-11 13:37:12ware Page +ar-aZ_.-..yr�,q ...olt HVAC15313 S 25th St Thomas Res PSL Prop.rup Calc=W8 Front Door laces: N I FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) R402.4.4 Rooms containing fuel-burning appliances In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1.Direct vent apliances with both intake and exhaust pipes installed continuous to the outside. 2.Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage. between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS El .R403.1 Controls rl R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory). All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/iCC 380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. El R403.3.2.1 Sealed air handler.Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(26 Pa)across the entire system,including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. I I R403.3.5 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. i R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55'F(13'C)s haft be insulated to a ninirrwm of R-3. rl R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 615. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature In the piping in accordance with the times when heated water is used in the occupancy. 2021-Nov-11 13:37:12 WrI1311It56W Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software page 8 w�rrs�r�,�s.rr ...ORHVACt5313S25thSt Thomas Res PSLPropsup Cate=MJ8 Front Door faces: N FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1 Storage water heater temperature controls. El R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). rl R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. El R403.5.6.2.1 Solar water heating system.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested In accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TMA,Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a lilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation,including: Natural,infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. El R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where mechanical ventilation fans are Integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shall meet the following criteria: 1.The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2.No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3.If ventilation air is drawn from enclosed spaces(s),then the wails of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved methodologies,heating and cooling calculation based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(If split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not Include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY j FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY(a) AIRFLOW RATE MAXIMUM CFM CFM/ WATT CFM Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 ---TBathroom, utility room 90 2.8 cfm/watt Any For Sl: 1 cfm-.28.3 L/min. (a)When tested in accordance HVI Standard 916 t +wirightsoft° Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section405.4.1 Compliant So are �yra�tysa. ..ym� ...oR HVAC15313 S 251h St Thomas Res PSL Prop.rup Calc=MJB Fronl Door faces: N Page 9 I i I MANDATORY REQUIREMENTS -(Continued) R403.7.1A Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1:15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1.Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2.When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized In accordance with good design practice. R403.7.1.2 Heating equipment capacity. El R403.7.1.2.1 Heat pumps Heal pump sizing shall be based on the cooling requirements as calculated according to Section R403.71.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1 R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions.Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1.A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2.A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and 0404 of the IECC--Commercial Provisions in lieu of Section R403. R403.9 Snow melt and Ice system controls(Mandatory). Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the systemw hen the pavement temperature is above 50"F(10°C),and no precipitation is failing and an automatic or manual control that w!Il allow shutoff w hen the outdoor temperature is above 40°F(4.8°C). rJ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an Integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1.Where public health standards require 24-hour pump operations. 2.Pumps that operate solar-and waste-heat-recovery pool heating systems. 3.Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2021-Nov-1l 13:37:12 Wrj9b%,Oft° Rig hl-Suite®Universal2021 21.0.08 RSU27054 Right-Energy®Flodda 2017 Section405A.1 Compliant are Page 10 tit r��3r..e�yrawi ...oR HVAC15313 S 25th St Thomas Res PSL Prop rup Catc=MJS Front Door faces:N MANDATORY REQUIREMENTS-(Continued) R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature_A test report from an Independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatory).The energy consumption of electrio-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception: Low-voitage lighting. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. i i i i f +i I +Wr!9ht50ft° Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section405A.1 compliiantSoftwarrel-Nov-11 1Page 2 wr rib=r=,aa.;+�y ...oft WAC15313 S 25th St Thomas Res PSL Prop.rup Calc=MJ8 Front Door faces: N Page 11 FORM R405-2017 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Thomas Residence Builder Name PSL Prop Street: 5313 S 25th St Permit Office: City,State,Zip: Fort Pierce,FL 34981 Permit Number: Owner: Thomas Residence Jurisdiction: St Lucie Design Location: FL,St Lucie Co Intl / COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA Y General A continuous air barrier shall be installed In the building envelope.The exterior thermal envelope Air- rmeabll�Insulation shall not be used as a requirements ❑ q contains a continuous barrier.Breaks or joints in thesealing rt air barrier shall be sealed. Celling/attic The air barrier in any dropped ceiling/soffit The Insulation in any dropped ceiling/soffit shall be aligned with the Insulation and any shall be aligned with the air barrier. gaps in the air barrier shall be sealed. ❑ Access openings,drop down stairs or knee wall doors to unconditioned attics paces shall be sealed. Walls The junction of the foundation and sill plate Cavities with corners and headers of frame walls shall be sealed.The junction of the top plate shall be insulated by completely filling the cavity and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 ❑ Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Windows,skylights The space between window/door jambs and framing, and doors and skylights and framing shall be sealed. ❑ Rim joists are insulated and include an air Rim joists shall be Insulated. El joists barrier. Floors(including The air barrier shall be Installed at any exposed Floor framing cavity Insulation shall be installed above-garage and edge of Insulation. to maintain permanent contact with the underside cantilevered floors) of subfloor decking,or floor framing cavity Insulation shall be permitted to be in contact El the top sideof sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space Exposed earth In unvented crawl spaces shall be Where provided In lieu of floor insulation, walls covered with a Class I vapor retarder with insulation shalt be permanently attached ❑ overlapping joints taped. to the crawispace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall ❑ be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by Insulation that El Installation readily conforms to the available cavity spaces. j Garage Air sealing shall be provided between the garage separation and conditioned spaces. ❑ Recessed Recessed light fixtures Installed in the building Recessed light fixtures Installed in the lighting thermal envelope shall be sealed to the drywall. building thermal envelope shall be air tight ❑ and IC rated. Plumbing and Batt insulation shalt be cut neatty to fit around wiring wiring and plumbing in exterior walls,or insulation that on installation readily conforms ❑ to available space shall extend behind piping and wiring. Showeritub on The air barrier shall be installed behind Exterior walls adjacent to showers and tubs exterior wall electrical or communication boxes or air-sealed shall be Insulated. ❑ boxes shall be installed. Electricallphone The air barrier shalt be installed behind ❑ box on exterior electrical or communication boxes or air-sealed walls boxes shall be installed. HVAC register HVAC;register boots that penetrate building boots thermal envelope shall be sealed to the subfloor ❑ or drywall. Concealed When required to be sealed,concealed fire sprinklers sprinklers shall only be sealed in a manner that is recommended by the manufacturer. El or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. in addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 2021-Nov-11 13:37:12 WA9htsofV Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 12 ...oft WACX5313 8 25th St Thomas Res PSL Prop.rup Calc=MJ8 Front Door faces: N i FORM R405-2017 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: St Lucie Permit Number: Job information Builder. PSL Prop Community: Lot: Address: 5313 S 25th St Unit: City: Fort Pierce State: FL Zip: 34981 Air Leakage Test Results Passingresults must meet eitherthePerfoimance,Prescriptive,orERIMethod. ❑ PRESCRIPTIVE METHOD The building or dwelling unit shall be tested'and,verified as having an-air leakage,rate of hot exceeding 7 air changes per hour at a pressure of 0.2 inch'w.g.,(50 pascals)in Climate Zones 1 and 2. El The building or dwelling unit shall be tested and verified as having an air leakage rate of not PERFORMANCE or ERI METHOD exceeding.the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration,sub-section ACH50. ACH(50)specified on Form R405-2017-Energy Cate(Performance)orR406-2017(ERI): 7,000 x60+ 16274 = Method for calculating building volume: CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans ❑ PASS Z Code software calculated When ACH(50)is less than 3,Mechanical Ventilation installation ❑ Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSIIRESNETIICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(0,(g),or(I)or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond Intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing"Gompany Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 2021-Nov-11 13:37:12 �nrrlghtsoft° Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Florida 2017 section 405A.1 CampBanl Software Page 13 nvr rr4 a,. oft HVAGIS313 S 25th St Thomas Res PSL Prop.rup Calc=MJ8 Front Door faces: N FORM R405-2017 Duct Leakage Test Report Residential Perscriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: St Lucie Permit Number: Job Information Builder: PSL Prop Community: Lot: Address: 5313 S 25th St Unit: City: Fort Pierce State: FL Zip: 34981 Duct Leakage Test Results System 1 cfm25 ❑ Prescriptive Method cfm25(Total) To qualify as`'substantially leak free"Qn Total must,be less System 2 cfm25 than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed,Qn Total must,be'less than or-equal to System 3 cfm25 0,03. This testing Method meets the requirements in accordance with Section R403.3:3. Sum of any Is the air handler unit installed <-0.04 QV additional systems cfm25 ❑'YES f- Total of all during testing? ❑ NO:"(—.6.03 Qm systems cfm25 ❑ Performance 1 ERI Method cfm25(Out or Total) 1766 _ Qn To qualify using this method,Qn must be not weaterthan the Total of all Total Conditioned proposed duct leakage Qn specified on Form R405-2017 or systems Square Footage R406-261 T Leakage Type selected on Form Qri specified on Form R405-2017 ❑ PASS ❑ FAIL R405-2017(Energy Cald).or R406-2017 (Energy calc)or R406-2017 Default Leakage C� Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553,993(5) or(7), Florida Statutes, or individuals licensed as set forth.in Section 489.105(3)(f), (g) or(i), Florida Statues. j Testing`Company` Company Name: Phone. I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 20+Wrjghtl:SQft° Right-Suite®Universal 2021 21.0.08 RSU27054 Right-Energy®Flodda 2017 Section 405.4.1 Compliant 5oftm el-Nov 11 13:37:12 ...oft HVAC15313 S 25th St Thomas Res PSL Prop.rup Calc=MJ8 Front Door faces: N Page 14 Reference Home Characteristics Thomas Residence Title:5313 S 25th St Thomas Res PSL Prop TMY City: FL-Fort-Pierce 5313 S 25th St FLBase2017 Fort Pierce,FL 34981 i Above-grade Walis(Uo) 0.084 Above-grade Wall Solar Absorptance 0.75 i Above-grade Wall Infared Emittance 0.90 Basement Walls(Uo) n/a Above-grade Floors(Uo) n/a Slab Insulation R-Value 0.0 Ceilings(Uo) 0.030 j Roof Solar Absorptance 0.75 Roof Infared Emittance 0.90 Attic VentArea(ftj 5.89 Crawls pace Vent Area(fI5 n/a Exposed Mason ryFloorArea(ft� 437.35 Carpet&Pad R-Value 2.0 Door Area(ft� 40.00 Door U-Factor 0.400 North Window Area(ft� 66.22 South Window Area(ft� 66.22 East WindowArea(ftl 66.22 West Window Area(ft� 66.22 Window U-Factor 0.400 Window SHGC(Heating) 0.2169 Window SHGC(Cooling) 0.2169 ACH50 7.00 Internal Gains"(Btu/day) 72237 Water heater gallons per day 60.00 Water Heater set point temperature 120.00 Water heater efficiency rating 0.95 Labeled Heating System Rating and Efficiency HSPF=8.2 Labeled Cooling System Rating and Efficiency SEER=14.0 ` Air Distribution System Efficiency 0.88 Thermostat Type Manual Heating Thermostat Settings 72.0(All hours) I Ii i i i i f� f 1 i w. lb: 128 Air.Calcs, LLC Load Short Form F$ e CO oatte: Jul 15,2020 House Z Q -fir Vicki Lynne Nisa M. LC D FOR DO E COMPLIANCE V1, 1C)P1q. 800.84l3 Email:vicidlyme@aircais.mm Project • • For. Thomas Residence,Air Conditioning Unlimited,LLC 5313 S 25th St,Fort Pierce,FL 34981 Design Information Htg Clg Infiltration Outside db(°F) 41 90 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD(°F) 29 15 Fireplaces 0 Daily range - L Inside humidity(%) 30 50 Moisture difference(gdlb) 2 57 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1SO42-230K* AHRI ref Coil CBA27UHE-042-230"++TDR AHRI ref 10259441 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating input 8.1 kW Sensible cooling 29400 Btuh Heating output 27587 Btuh Latentcooling 12600 Btuh Temperature rise 18 °F Total cooling 42000 Btuh Actual airflow 1400 cfm Actual airflow 1400 cfin Airflowfactor 0.049 cfimBtuh Airflowfactor 0.049 cfmBtuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.81 ROOM NAME Area Htg load Clg load Htg AVF CIgAVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Bed 2 161 : 2830 1781 140 88 Bath 2 54 726 386 36 19 Lin 6 0 0 0 0 Hall 30 0 0 0 0 Bed 3 173 3070 2151 151 106 Family Room 185 4286 5645 211 278 Kitchen/Nook 215 1963 5095 97 251 Living Room 266 1950 4106 96 202 Laundry 77 1064 889 52 44 Dining Room 108 2190 1885 108 93 Foyer 72 1146 607 57 30 Wtr Clst 28 1275 604 63 30 Linen 5 0 0 0 0 WIC 42 764 251 38 12 Calculations approved byACCAto meet all requirements of Manual Jf � �a wrilghtsofta �� +�J 2021-Nov 11 13:33:35 RightSUte®Uriversal202121.0.08RSU27054 LJ ACM oft HVAC15313 S 25th St Thomas Res PSL Prop.rup Calc=MJ8 Front Doorfaces:N Pagel P Master Bath 129 1652 828 82 41 Master Bedroom 217 5459 4225 .269 208 House d 1766 28375 28454 1400 1400 Other equip loads 1519 807 " Equip.@ 0.95 RSM 27914 Latent cooling 7063 TOTALS 1766 29894 34977 1400 1400 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �-wrightsofta 2021-Nov-11 13:33:35 Right Sute®Uriversal2021 21.0.08 RSU27054 Page 2 ...oft HVAC\5313 S 25th St Thomas Res PSL ProPrup Calc=MJ8 Front Door faces:N Job: . 1282 Building Analysis Dace: Jul5,2020 Air.Calcs, LLC House By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:v cidly"°Qaircalks.com. Project • • For. Thomas Residence,Air Conditioning Unlimited,LLC 5313 S 25th St,Fort Pierce,FL 34981 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(OF) 70 75 Elevation: 26 ft Design TD(OF) 29 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 2.4 56.9 'Dry bulb(OF) 41 90 Infiltration: Daily range(OF) - 15 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh %of load Walls 3.1 4597 15.4 wall ventilation Glazing 17.5 5887 19.7 Doors 3.7 148 0.5 acts Ceilings 0.9 1654 5.5 Floors 3.4 5949 19.9 Infiltration 2.0 3285 11.0 Glazin °L Ducts 6856 22.9r Piping 0 0 Humidification 0 0 Infiltration Ventilation 1519 5.1 Other Adjustments 0 Ceilings Total 29894 100.0 Floors Component Btuh/ft2 Btuh %of load Walls 1.9 2752 9.4 Wall ventilation Glazing 22.8 7641 26.1 Doors 3.7 150 0.5 ntemal Gains Ceilings 0.8 1348 4.6 " Floors 0 0 0 Glazing " - Infiltration 0.6 918 3.1 . Ducts 7624 26.1 Ventilation 807 2.81 Internal gains 8020 27.4 Blower 0 0 other Adjustments 0 Other Total 29260 100.0 Ducts Latent Cooling Load=7063 Btuh Overall U-value=0.117 Btuh/ftZ°F Data entries checked. -F- =rightsc fto 2021-Nov-11 13:33:35 .� •W�� Right-Sute®Universal 20.2121.0.08RSU27054 Pagel �A ...aft HVACZ313S25thSt Thomas Res PSLProp.rup Calc=MJ8 FrontDoorfaces:N r Air.Calcs, LLC Component Constructions Job:: Jul 15,2020 House By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock LR Vero Beads,FL32966 Phone:772.800.8413 Email:v1ddlynne@aircalcs.com Project • • For. Thomas Residence,Air Conditioning Unlimited,LLC 5313 S 25th St,Fort Pierce,FL 34981 Design Conditions Location: Indoor: Heating Cooling St Lucie Co Intl,FL,US Indoor temperature(OF) 70 75 Elevation: 26 ft Design TD CF) 29 15 Latitude: 28°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grAb) 2.4 56.9 Dry bulb(°F) 41 90 Infiltration: Daily range(OF) - 15 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U value Insul R Htg HTM Loss Clg HTM Gain ft' BtuhdvF ft;°ABluh Btuhlft' Btuh BtuhvT Btuh Walls Blk Wall,Stucco Ext,R-4.1 Ext Bd Ins,8"Thk,1/2"Gyp Bd Int Fnsh n 41 0.109 5.1 3.15 130 2.02 83 ne 300 0.109 5.1 3.15 944 2.02 604 se 208 0.109 5.1 3.15 654 2.02 419 sw 372 0.109 5.1 3.15 1172 2.02 750 nw 315 0.109 5.1 3.15 992 2.02 634 all 1235 0.109 5.1 3.15 3892 2.02 2490 Partitions Frm Wall,1/2"Gyp.Bd Ext,R-11 Cav Ins,1/2"Gyp Bd Int Fnsh,2'k4",16" 240 0.101 11.0 2.94 705 1.09 262 OC Stud Windows Impact,ClearLow-e:Impact,Clear Lowe;NFRC rated(SHGC=0.21); n 39 0.650 0 18.8 726 11.9 459 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);14 ft overhang(6.7 ft window ht,3 It sep.);6.8 It head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); ne 5 0.580 0 16.8 81 27.4 131 foreground=green grass(0.23);1 ft overhang(1.2 ft window ht,1 It sep.); 6.8 ft head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); ne 16 0.580 0 16.8 262 22.3 347 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);1 ft overhang(5.2 ft window ht,1 ft sep.);6.8 ft head ht sw 31 0.580 0 16.8 525 21.5 669 all 47 0.580 0 16.8 787 21.7 1017 Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); se 10 0.580 0 16.8 161 16.0 153 foreground=green grass(0.23);6.6 ft overhang(1.6 ft window ht,1 ft sep.);6.8 ft head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); se 41 0.580 0 16.8 686 21.7 886 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);1 ft overhang(6.8 It window ht,1 ft sep.);9 ft head ht Impact,Clear Lowe,TEMP:Impact,Clear Lowe,TEMP;NFRC rated se 9 0.580 0 16.8 151 20.6 186 (SHGC=0.24);50%blinds 45°,medium;50%outdoor insect screen; foreground=green grass(0.23);1 ft overhang(3 ft window ht,1 ft sep.); 6.8 ft head ht !�C wrigf,ttscift 2021-Nov 11 13:33:35 Alm�L Right Skite®Universal 2021 21.0.08 RSU27054 Page 1 aft HVAC15313 S 25th StThomas Res PSL Prop.rup Calc=MJ8 Front Door faces:N Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); sw 16 0.580 0 16.8 262; 13.4 209 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);20 ft overhang(5.2 ft window ht,3 ft sep.);6.8 ft head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.21); sw 40 0.650 0 18.8 747 22.0 871 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);1 ft overhang(6.7 ft window ht,3 ft sep.);6.8 ft head ht Impact,TEMP,OBSC:Impact,TEMP,OBSC;NFRC rated(SHGC=0.24); sw 6 0.580 0 16.8 101 25.1 151 foreground=green grass(0.23);1 ft overhang(3 ft window ht,1 ft sep.); 6.8 ft head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated SHGC=0.24); nw 47 0.580 0 16.8 787 22.3 1041 P P ( 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);1 ft overhang(5.2 ft window ht,3 ft sep.);6.8 ft head ht Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.24); nw 16 0.580 0 16.8 262 22.3 347 50%blinds 45°,medium;50%outdoor insect screen;foreground=green grass(0.23);10 ft overhang(5.2 ft window ht,3 ft sep.);6.8 ft head ht nw 23 0.580 0 16.8 386 22.3 511 all 39 0.580 0 16.8 649 22.3 858 Impact,Clear Lowe:Impact,Clear Lowe;NFRC rated(SHGC=0.21); nw 40 0.650 0 18.8 747 21.7 860 50%blinds 45',medium;50%outdoor insect screen;foreground=green grass(0.23);16 ft overhang(6.7 ft window ht,3 ft sep.);6.8 ft head ht Doors Door,wd sc type:Fbrgls Door se 40 0.127 7.0 3.69 148 3.73 150 Ceilings Attic,Shngl Roof,R-30 Ceil Ins,112"Gyp Bd Int Fnsh 1766 0.034 30.0 0.94 1654 0.76 1348 Floors On Grade Depth,Tile Fir Fnsh 207 0.989 0 28.7 5949 0 0 t 4 wrightsoft- 2021-Nov-1113:33:35 .W,+I RightSute®Uriversal202121.0.08RSU27054 Page ...oftWACW13S25thStThomasResPSLPropnq Carc=MJ8 FroMDocrfaces:N Project Summary Job: Air Calks, LLC � ry Jul Date: Jul 15,2020 House By.. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:viddlyme@aircalcs.com Project • • For. Thomas Residence,Air Conditioningg Unlimited,LLC 5313 S 25th St,Fort Pierce,FL 34951 Notes: D- • • • ' Weather: St Lucie Co Inti,FL,US Winter Design Conditions Summer Design Conditions Outside db 41 °F Outside db 90 of Inside db 70 of Inside db 75 of Design TD 29 °F Design TD 15 of Daily range L Relative humidity 50 % Moisture difference 57 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21520 Btuh Structure 20829 Btuh Ducts 6856 Btuh Ducts 7624 Btuh Central vent(48 cfm) 1519 Btuh Central vent(48 cfm) 807 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29894 Btuh Use manufacturer's data n Rate/swin multipplier 0.95 Infiltration Equiprrien�sensibleload 27914 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2896 Btuh Ducts 2325 Btuh Central vent(48 cf-n) 1842 Btuh Heating Cooling Outside air Area(ft2) 1766 1766 Equipment latent load 7063 Btuh Volume(fN) 16274 16274 Air changes/hour 0.38 0.20 Equipment Total Load(Sen+Lat) 34977 Btuh Equiv.AVF(cfm) 103 54 Req.total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1SO42-230A** AHRI ref Coil CBA27UHE-042-230*++TDR AHRI ref 10259441 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Heating Input 8.1 kW Sensible cooling 29400 Btuh Heating output 27587 Btuh Latentcooling 12600 Btuh Temperature rise 18 'F Total cooling 42000 Btuh Actual airflow 1400 cfrn Actual airflow 1400 cfm Airflowfactor 0.049 cfm/Btuh Airflowfactor 0.049 cfnBtuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -� wri-ghtsoft' 2021-Nov-1113:33:35 y_r •W' —� Right Skite®Uriversal 2021 21.0.08 RSU27054 Page 1 ACi(i�...oftHVAC15313S251hStThomas Res PSLProprup Calc=MJ8 FrontDoorfaces:N Air Calks, LLC Right-M Worksheet Job: 1282 House Date: Jul 15,2020 By. Vicki Lynne Nisa Air Calks, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:vidtilyme@aircalcs.com 1 Room name House Bed 2 2 F)rosedwell 207.4 ft 29.0 It 3 Room height 92 ft d 8.1 ft heat/cool 4 Room dimensions 1.0 x 161.3 it 5 Room area 1765.8 f12 161.3 T Ty Construction U-value Or HTM Area (q Load Area (its Load number (BtuhAN-°F) (StuhAtj or perimeter @ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NrP/S Heat Coal Gross NA'IS Heat Cool 6 1qJ Blk Wall,St ozo Erd 0.109 n 3.15 2.02 80 41 130 83 0 6 0 0 'G Impail Clear Low-e 0.650 n 18.85 11.92 39 0 726 459 0 0 0 0 W Blk Wall,Stumo Ed 0.109 ne 3.15 2.02 320 300 944 604 113 98 308 197 Impact Clear Lowe 0.580 ne 16.82 27.37 5 0 81 131 0 0 0 0 11 Impact,Clear Lowe 0.580 ne 16.82 2225 16 0 262 347 16 0 262 347 Blk Wall,Stu Mai 0.109 se 3.15 2.02 307 208 654 419 0 0 0 0 Impaa Clear Lowe 0.580 se, 16.82 15.96 10 10 161 153 0 0. 0 0 Imh a4.Cle&Low-e uw se 16.82 21.72 41 4 686 888 0 0 0 0 Impact;Clear Lowe, 0.580 se 16.82 20.64 9 2 151 166 0 0 0 0 Door,Ad sctyp6„ 0.127 se_ 3.69 3.73 40 40 148 150 0 0 0 0 Slk Wall,Stucco Ext 0.109 sw 3.15 2.02 464 372 1172 750 0 0 0 0 Impact Clear Lowe 0.580 sw 16.82 21.46 31 4 525 669 0 0 0 0 Impact Clear Low-e 0.580 sw 16.82 13.37 16 16 262 209 0 0 0 0 Impact,Clear Lowe 0.650 sw 18.85 21.98 40 0 747 871 0 0 0 0 Impact,TEMP,ORS C 0.580 sw 16.82 25.11 6 1 101 151 0 0 0 0 BlkWal1,St k6o Ext' 0.109, rw 3.15' 2,02 440, 315 192 634 0 0 0 0 Impact Clean Lowe 0.580 _nw 16.82 2225 47 .0 787 1041 0 0 0 0 Impa�Clear Lowe 0.580 rfw 16.82. 2225 16 0 262 347 0 0- 0 0 ImZCl6arLo4e 0.580 nw 16.82 22.25 23 0 386 511 0 0 0 0 ImpacClearLowe. 0.650. nw 18.85. 21.70 40 0 747 860 0 0 0 0 P Frm Wall,121yp G .B 0.101 - 2.94 1.09 240 240 705 262 122 122 357 133 C Attic Shhgl Roof R 0.034 - 0.94 0.76 1766 1766 1654 1348 161 161 151 123 F On Grade Depth,Tile 0.989 28.68 0.00 1766 207 5949 0 161 29 832 0 6 c)AED exwrsion 819 -65 Envelopeloss/gain 18235 11891 1910 736 12 a) Infiltration 3285 918 231 65 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants @ 230 4 920 0 0 Appliancestother 7100 500 Subtotal(lines 6 to 13) 21520 20829 2141 1300 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 5 4 14 Subtotal 21520 20829 2146 1304 15 Ductloads 320/. 37% 6856 7624 321/6 37o/a 684 477 Total room load 28375 28454 2830 1781 Air required(cfm) 11400 1400 140 88 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrtgtftsoft- 2021-Nov 11 13:33:35 Right-Srite®Universal 2021 21.0.08 RSU27054 Page 1 ...oft WACZ313 S 25thStThomas Res PSL Prop.rup Calc=MJ8 FrontDoorfaces:N Air Calcs, LLC Right-J®Wbrksheet Jab: 1282 House Date: Jul 15,2020 By. Vicki Lynne Nisa Air Calm, LLC. 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:,Addlyme@aircalcs.com 1 Room name Bath 2 Lin 2 Fposed wall 6.0 It 0 ft 3 Room height 8.1 It heatl000l 8.1 It heat/cool 4 Room dimensions 9.0 x 6.0 It 2.5 x 25 It 5 Room area 54.0 ft' 6.3 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load number (BtuhNL*F) (BtuhAn or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NAPS Heat Cool 6 W Blk Wall;StL(oM 6d 0.109 n 3.1;5 202 0 0 0 0 0 0 0 6 Impact;Clear.Lwµe 0.650 n 18.85 11.92 0 0 0 0 0 0 0 0 W Blk Wall,Stucco 6d 0.109 ne 3.15 2.02 49 44 138 88 0 0 0 0 Impact,Clear Low-e 0.580 ne 16.82 27.37 5 0 81 131 0 0 0 0 11 Impact,Clear Low-e 0.580 ne 16.82 2225 0 0 0 0 0 0 0 0 Blk Wall;Stucoo E)d 0.'109 se 3.15 2.02 0 0 0 0 0 0 0 0 Impact,ClearL6*p- 0.580 --se 16.82 15.96 0 0 0 0 0 0 0 0 ImpactClearl-owe 0.580 se 16.82 21.72 0 0 0 0 0 0 0 0 Impact Clear Lowe, 6.580 se 16.82 20.64 0 0 0 .0 0 0 0. 0 Door;vdscm- 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 Blk Wall,Stumo Ext 0.109 Sw 3.15 2.02 0 0 0 0 0 0 0 0 Impact;Clear Lowe 0.580 sw 16.82 21.46 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.580 sw 16.82 13.37 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.650 sw 18.85 21.98 0 0 0 0 0 0 0 0 Impact TEMP,OBSC 0.580 sw 16.82 25.11 0 0 0 0 0 0 0 0 Blk Wall;Shiozi 6d 0.109 nw 3.15 202 0 0 0 0 0: 0 0 0 lmpact learLowe 0.580 nw 16.82 2225 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 nw 16.82 22.25 0 0 0 0 0 0 0 0 Impad,Clear.Low-e 0.580 rnw 16.82 2225 0 0 0 0 0 0 0 0 Impact ClearLo�Fe 0.650 nw 18.85 21.70 0 0 0 0 0 01 0 0 P Frm Wall,1/2''Gyp.B 0.101 - 2.94 1.09 0 0 0 0 0 0 0 0 C Attiq 8Ii6glRoof;R. 0.034 - 0.94 0.76 54 54 51 41 6 6 6 5 F On Grade Depth,Tile 0.989 - 28.68 0.00 54 6 172 0 6 0 0 0 6 c)AED exarsion -14 0 Emelope,losstgain 441 247 6 5 12 a) Infiltration 99 28 0 0 b) Room ventilation 0 0 0 0 13 Internal gains Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Oines 6 to 13) 540 275 6 5 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 8 -6 -5 14 Subtotal 550 282 0 0 r Dudloads 32% 37% 175 103 32% 37% 0 0 Total room load 726 386 0 0 Air required(dm) 36 191 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -+ wrtghtsoft� 2021-Nav-1113:33:35 �A -'-7 Right-Sute@Universal 2021 21.0.08 RSU27054 Page 2 ...oft HVAC15313 S 25th St Thomas Res PSL Prop.np Calc=MJ8 Front Door faces:N Air Calcs, LLC RI ht-JO Worksheet Job: 1282 HOUSE Date: Jul 15,2020 By. Vicki Lynne Nisa Air Calks, LLC 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:viddlyme@aircalcs.com 1 Room name Hall Bed 3 2 Exposed wall 0 It 27.5 It 3 Room height 8.1 ft heal/oDol 8.1 ft heaUcooi 4 Room dimensions 3.5 x 8.5 It 1.0 x 172.5 It 5 Roam area 29.8 T 172.5 IF Ty Construction U-value Or HTM Area (ft2) Load Area (ftF) Load number (BtuhAt-°F) (Btu or perimeter (ft) (Btuh) or perimeter (It) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NrP/S Heat Cool 6 %t Blk Wall,SWoob EA 0.109 n 3.15 Z02 0 0 0 0 0 0 0 0 Impact Clear Low-e 0.650 n 18:85 11.92 0 0 0 0 0 0 0 0 W Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 122 122 383 245 Impact Clear Lowe 0.580 ne 16.82 27.37 0 0 0 0 0 0 0 0 11 Impact,Clear Lowe 0.580 ne 16.82 22.25 0 0 0 0 0 0 0 0 Blk Wall,Stukno ESQ 0.109 se 3.15. Z02 0 0 0 0 0 0. 0 0 Impact,Cleat Lowe 0.580 "se 16.82' 15.96 0 0 0 0 0 0 0 0 w Impac;Clear Loe 0.580 se 16.82. 21.72 0 0 0 0 0 0 0 0 Impact Clear Lowe, 0.580 se 16.82 20.64 0 0 0 0 0 0 0 0 Door,vtdsctype 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.580 sw 16.82 21.46 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 sw 16.82 13.37 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.650 -v 18.85 21.98 0 0 0 0 0 0 0 0 Impac,TEMP,OBSC 0.580 sw 16.82 25.11 0 0 0 0 0 0 0 0 Blk Wall,Stu000 E)d 0:106 nw 3A 8 2.62 0 0 0 0 101 86 270 173 Impact Clear Lowe 0.580 nw 16.82` 9995 0 0 0 0 16 0. 262 347 Impact,Clear.Lowe 0.580 nw- 16.82 2225 0 0 0 0 0 0 0 0 Impact ClearLow-e 0.580 nw 16.82 2225 0 0 0 0 0 0 0 0 Impc4 Clear Lowe 0.650 nw 18.85 21.70 0 0 0 0 0 0 0 0 P Frm Wall,10 Gyp.B 0.101 - 2.94 1.09 0 0 0 0 0 0 0 0 C Attic;ShngLRaof R 0.034 - 0.94, 0.76 30 30 28 23 173 173 162 132 F On Grade Depth,Tile 0.989 - 28.68 0.00 30 0 0 0 173 28 789 0 6 c)AED e)=rsion -1 45 Envelopelossrgain 28 22 1865 941 12 a) Infiltration 0 0 454 127 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliancesrother 0 500 Subtotal pines 6 to 13) 128 22 2320 1568 Less e)demalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution -28 -22 8 7 14 Subtotal 0 0 2328 1575 15 Dud loads 132% 371/. 0 0 329/.1 37%1 742 576 Total room load 0 0 3070 2151 Air required(cm) 0 0 151 106 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wr®gF�tsoR 2021-Nov1113:33:35 RigM-Sute@ Universal 202121.0.08RSU27054 Page3 oft HVAC5313S25thSt Thomas Res PSLProp.rup Calc=MJ8 FrontDoorfaces:N Air Calcs; LLC Ri ht-JO Worksheet Jab: 1282 ' House Date: Jul 15,2020 By Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:viddlyme@aircalcs.com 1 Room name Family Room Mtchen/Nock 2 Exposed mall 25.0 ft 10.5 ft 3 Room height 10.1 ft heaUoocl 10.1 ft heaVcool 4 Room dimensions 1.0 x 185.0 ft 1.0 x 214.5 ft 5 Room area 185.0 ft, 214.5 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuhi t-°F) (Btu or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NuP/S Heat Cool Gross N/P/S Heat Cool 6 BIk Wall,SWoco End 0.109 n 3.15 2.02 0 0 0 0 0 0 0 0. r_ Impact,ClearLow-e 0.650 n 18.85 11.92 0 0 0 0 0 0 0 0 V111 - Blk Wall,Stucco Ext 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 �--ci Impact,Clear Low-e 0.580 ne 16.82 27.37 0 0 0 0 0 0 0 0 11 C Impact,Clear Low-e 0.580 ne 16.82 2225 0 0 0 0 0 0 0 0 Blk Wall,SMom Ext 0.10.9 ,se 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Cl ear Low-e U80 � 16.82 15.96 0 0 0 0 0 0 0 0 ImpactglearLcw-e 0.580-.se 16.82 21.72 0 0 0 0 0 0 0 0 Impact Clear Lowe, 0.580 se 16.82 20.64 0 0 0 0 0 0 0 0 Door,M-type 6127 se 3.69, 3.73 0 0 0 0 0 0 0 0 Blk Wall,Stucco Ext 0.109 sw 3.15 2.02 101 61 193 124 61 45 142 91 Impact Clear Lowe 0.580 sw 16.82 21.46 0 0 0 0 0 0 0 0 Impact,Clear Low-e 0.580 sm 16.82 13.37 0 0 0 0 16 16 262 209 Impact ClearLov.e 0.650 sw 18.85 21.98 40 0 747 871 0 0 0 0 Impact,TEMP,OBSC 0.580 sw 16.82 25.11 0 0 0 0 0 0 0 0 Blk Wall,Stucco,EiQ o.109 riw 3.15 2.02 152 120 379 242 45 30 94 60 Impact,CIearLrn-e 0.580 nw 16.82' 2225 31 0 525 694 0 0 0 0 impact cleacLow-e 0.586 rtw 16.82 2225 0 0 0 0 16 0 262 347 Impact;ClearLow4 0.580 rw 16.82 2225 0 0 0 0 0 0 0 0 mock Clear 0.650 nw 18.85 21.70 0 0 0 0 0 0 0 0 P Frm Wall,12'Gyp:B 0.101 2.94 1.09 0 0 0 0 0 0 0 0 C At5G Shngl Roof,R 0.034 0:94 0.76 185 185 173 141' 215 215 201 164 F On Grade Depth,Tile 0.989 28.68 0.00 185 25 717 0 215 11 301 0 6 c)AED excursion 185 132 Envelopeloss/gain 2735 2258 1263 1002 12 a) Infiltration 515 144 216 60 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 2 460 Appliances(other 1500 2200 Subtotal Qines 6 to 13) 3249 4132 1479 3723 Less extemalload 0 0 0 0 Less transrer 0 0 0 0 Redistibution 1 1 10 a 14 Subtotal 3251 4133 1489 3730 15 Duct loads 32% 37% 1036 1513 32% 37% 474 1365 Total room load 4286 5645 1963 5095 Air required(dm) 1 211 278 97 251 Calculations approved byACCAto meetall reguirementsofManual J 8th Ed. - wrlghtsolFt 2021-Nov-1113:33:35 Right-Sute@ Universal 2021 21.0.08 RSU27054 Page 4 ...oftWAC\5313 S 25thStThomas Res PSL Prop.rup Calc=MJ8 Front Door faces:N Air Caics, LLC Right-JO Worksheet Job: 1282 House Date: Jul 15,2020 By-. Vicki Lynne Nisa Air Caics, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800.8413 Email:viekilyme@aircalcs.com 1 Room name Living Room Laundry 2 Exposed well 7.5 It 14.0 It 3 Room height 10.1 It heat/cool 8.1 it heat/ocol 4 Room dimensions 1.0 x 265.5 ft 7.0 x 11.0 It 5 Room area 265.5 ft' 77.0 1F Ty Construction U-value Or HTM Area (ft� Load Area (ftF) Load number (BIuhA1--F) (BtuhAn or perimeter (ft) (Btuh) or perimeter (ft) (Bhrh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coal 6 VIl Blk Wall;Stucco Ext 0.109 n 3.15 202 0 0 0 0 0 0 0 0 L� Impact Clear Lowe 0.650 n. 18.85 11.92 0 0 0 0 0 0 0 0 IWI ^_ Elk Wall,Stuan Ext 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 C' Impact Clear Low-e 0.580 ne 16.82 27.37 0 0 0 0 0 0 0 0 11 i . _Impact ClearLow-e 0.580 ne 16.82 2225 0 0 0 0 0 0 0 0 Elk Wall Stucoo Ext 0.1.09 se 3.15 202 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 se 16.82 15.96 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 se_ 16.82 21.72 0 0 0 0 0 0 0 0 Impact,Clea-rLowe, 0.586 _se 16.82 20.64 0 0 0 0 0 0 0 0 DtxN,otdsctype , 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 Blk Wall,Stucco Ext 0.109 sw 3.15 202 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 sw 16.82 21.46 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 sw 16.82 13.37 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.650 Snr 18.85 21.98 0 0 0 0 0 0 0 0 Impact TEMP,OBSC 0.580 Sir 16.82 25.11 0 0 0 0 0 0 0 0 Elk Wall,Stucco Ext 0.109'.nw 3.15 2.02 76 36 114 73 0 0 0 0 Impact;'CleatLow•e 0.580 nw 16.82 2225 0 .0 0 0 0 0 0 0 impactClearLaw 80 e 05 ._nw 16.82 2225 0 0 0 0 0 0 0 0 mpack Clear.Lovvre 0.580 n 16.82 2225 0 0 0 0 0 0 0 0 Impact Cle4,,Lcwe 0.650 . nw 18.85 21.70 40 0 747 860 0 0 0 0 P Frm Wa11,121 Gyp.B 0.101 - 2.94 1.09 0 0 0 0 113 113 333 124 C Atha ShnglAoof,R 0.034 - 0..94 0.76 266 266 249 203 77 77 72 59 F On Grade Depth,Tile 0.989 - 28.68 0.00 266 8 215 0 77 14 402 0 6 c)AED exarsion 197 -32 Envelope loss(gain 1325 1333 807 150 12 a) Infiltration 154 43 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 1 230 0 0 Appliancesrother 1400 500 Subtotal(lines 6 to 13) 1479 3006 1807 650 Less ademal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1479 3006 807 650 15 Duct loads 32°/a 37% 471 1100 32% 37% 257 238 Total room load 1950 4106 1064 889 Air required(cm) 1 196 202 1 152 44 Calculations approved byACCAto meetall requirements of Manual J 8th Ed. - wrlg-l-�tsotFt^ 2021-Nov-11 13:33:35 RighFSute®Universal 202121.0.08RSU27054 Page oft HVAC\5313 S 25th St Thomas Res PSL Proprup Calc=MJ8 FrontDoorfaces:N Air Calcs, LLC Right-JO Worksheet Job: 1282 HouseDate: Jul 16,2020 By: Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beady FL 32966 Phone:772.8002413 Email:viddlyme@aircalcs.com 1 Room name Dining Room Foyer 2 Exposedv.WI 125 ft 8.0 It 3 Room height 10.1 ft heat/mol 10.1 ft heaUcool 4 Room dimensions 12.0 x 9.0 ft 8.0 x 9.0 ft 5 Room area 108.0 T 72.0 it' Ty Construction U-value Or HTM Area (ft?) - Load Area (ftl Load number (BtuhAt;°F) (Btuh1Rl or perimeter (ft) (BWh) I or perimeter (ft) (Btuh) Heat Cool Gross NA'/S Heat Cool Gross N/P/S Heat Cool 6 %f Blk Wall,StuccoEX 0.109 n 3.15 202 0 0 0 6 0 6 . 0 0 I, G Impact ClearLowFe 0.650 n 18.85. 11.92 0 0 0 0 0 0 0 0 IW - Blk Wall,Stucco EM 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 I--ci Impact,Clear Low-e 0.580 ne 16.82 27.37 0 0 0 0 0 0 0 0 11 i C_ impact Clear Low-e 0.580 ne 16.82 2225 0 0 0 0 0 0 0 0 Blk Wall,Stucrdo E-A 0.109 se 3.15 2.02 121 80 253 162 81 31 98 62 Impact Clear Lowe. 0.580 se 16.82 15.96 0 0 0 0 10 10 161 153 Impact,Clear Low e 0.580 se 16.82 - 2112 41 4 686 886 0 0 0 0 Impact.,ClearLow-e 0.580 se 16.82 20.64 0 0 0 0 0 0 0 0 Door,ud sctype 0.127 se" 3.69 3.73 0 0 0 0 40 40 148 150 Blk Wall,Sturm Ext 0.109 sw 3.15 2.02 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.580 sw 16.82 21.46 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.580 sw 16.82 13.37 0 0 0 0 0 0 0 0 Impact,Clear Lowe 0.650 sw 18.85 21.98 0 0 0 0 0 0 0 0 Impact,TEMP,OBSC 0.580 sw 16.82 25.11 0 0 0 0 0 0 0 0 Blk Stucco Stucco Ext 0.109 nw 3:15 . 2.02 0 0 0 0 0 0 0 0 Impact CleerLowe 0.580 .nw 16.82 999 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 nw 16.82 2225 0 0 0 0 0 0 0 0 Impacl;ClearLowe 0.580 nw 16.82 2225 0 0 0 0 0 0 0 0 Impacl;Clear.Lcrjie o.650 rw 18.85 21.70 0 0 0 0 0 0 0 0 P Frm Wall,IQ"Gyp.B 0.101 - 294 1.09 5 5 15 6 0 0 0 0 C Attic Shrigl Roof R 0.034 - 0.94 0.76 108 108 101 82 72 72 67 55 F On Grade"Depth,Tile 0.989 - 28.68 0.00 108 13 359 0 72 8 229 0 6 c)AED exarsion 175 -22 Envelope loss(gain 1414 1311 704 398 12 a) Infiltration 247 69 165 46 b) Roam ventilation 0 0 0 0 13 Internal gams: Occupants@ 230 0 0 0 0 Applianoes/other 0 0 Subtotal(lines 6 to 13) 1661 1380 869 444 Less extemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1661 1380 869 444 15 Ductloads 32% 37%1 529 505 32% 371/6 277 163 Total room load 2190 1885 1146 607 Air required(cfm) 108 93 57 30 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -rw wrtgF2tsot T - 2021-Nav-1113:33:35 Right Sute@ Universal 2021 21.0.08 RSU27054 Page 6 ...oftHMACl5313S25thSt Thomas Res PSLProp.rup CaIc=MJ8 FrontDoorfaces:N Air Calcs, LLC Right-JO Worksheet Job: 1282 House Date: Jul 15,2020 By: Vicki Lynne Nisa Air Calks, LLC 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:,Addlynne@aircalcs.com 1 Room name Wlr Clst Linen 2 Exposed Hell 11.5 It 1.5 It 3 Room height 8.1 it heat/000l 8.1 It heaUmol 4 Room dimensions 3.5 x 8.0 ft 3.5 x 1.5 It 5 Room area 28.0 1? 5.3 IF Ty Construction U-value Cr HTM Area (fly Load Area (ft) Load number (BtuhAP--°F) (BtuhAt2) or perimeter (ft) (BWh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Blk Wall,Stuau E)d 0.1009 n 3.15 2:02 0 0 0 0 0 0 0 0 _G Impact,Cleaar Law a 0,660 n 18.85 11.02 0 0 0 0 0 0 0 0 W Blk Wall,Stumo F)d. 0.109 ne 3.15 2.02 0 0 0 0 0 0 0 0 Impact ClearLov-e 0.580 ne 16.82 27.37 0 0 0 0 0 0 0 0 11 impact Clear Lowe 0.580 ne 16.82 22.25 0 0 0 0 0 0 0 0 Blk Wall,Steno F)d .0.109 se 3.15. 2.02 28 28 89 57 0 0 0 0 Impact Clear Lowe 0.580 se 16.82 15.96 0 0 0 0 0 0 0 0 Impact ClearLawe 0.580 se 16.82 21.72 0 0 0 0 0 0 0 0 Imoc(Clear Lowe, 6.586 se 16.82 20.64 0 0 0 0 0 0 0 0 Doan,ndsctype 0.127 se 3.60.. 3.73 0 0 0 0 0 0 0 0 Blk Wed],Stuob 6d 0.109 sw 3.15 2.02 65 59 185 119 12 12 38 24 Impact Clear Low.e 0.580 sN 16.82 21.46 0 0 0 0 0 0 0 0 ImpagClearLowe 0.580 snr 16.82 13.37 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.650 sN 18.85 21.98 0 0 0 0 0 0 0 0 Impact,TEMP,OBSC 0.580 sw 16.82 25.11 6 1 101 151 0 0 0 0 BIMall,Stuom F)d 0:409 'riv✓ 3.15 2.02 0 0 0 0 0 0 0 0 Impa4 C16ar LaA a 0.'580 riw 16.82 2225 0 0 0 0 0 0 0 0 mpactClearLowe 0.580 nw 16.82 _ 2225 0 .0 0 0 0 0 0 0 Impac,ClearLowe 0.580 'nw 16.82 2225 0 0 0 0 - 0 0 0 0 Impact Clear Lowe 0.650 riw 18.85 21.70 0 0 0 0 0 0 0 0 P Fmt Wall,1l2"Gyp.B 0.101 - 2.94 1.09 0 0 0 0 0 0 0 0 C Attic;Shngl Rgof,R 0.034 - 0.94 0.76 28 28 26 21 5 5 5 4 F On Grade Depth,Tile 0.989 - 28.68 0.00 28 12 330 0 5 2 43 0 6 c)AED exoursion 27 -2 Emelopeloss(gain 732 375 86 27 12 a) Infiltration 190 53 25 7 b) Room ventilation 0 0 0 0 13 Intemalgains Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(Iines 6 to 13) 921 428 111 34 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 46 14 -111 -34 14 Subtotal 967 442 0 0 151 uctloadS I321/o 37% 308 162 329/o 37o/a 0 0 Total room load 1275 604 0 0 Air required(dm) L 1 63 30 0 0 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. 'FI'F wrYgF�tsoTt' 2021-Nov-1113:33:35 .4 R gM Sute®Uriversa12021 21.0.08 RSU27054 Page 7 ...oftHVAC\5313S25thSt Thomas Res PSLPropsup Catc=MJ8 Front Door faces:N Air Calcs, LLC Right-M)Worksheet Job: 1282 HOUSe Date: Jul 15,2620 By: Vicki Lynne Nisa Air Calks, LLC 7550 Hidden Hammock LR Vero Beads,FL32966 Phone:772.800.8413 Email:,Addlyrre@aircalcs.com 1 Room name VVIC Maser Bath 2 Exposed well 7.0 It 14.0 It 3 Room height 8.1 It heaticool 8.1 It heatlmol 4 Room dimensions 1.0 x 41.5 It 1.0 x 128.8 ft 5 Room area 41.5 ft' 128.8 tt= Ty Construction U-value Or HTM Area (M Load Area (M Load number (Btuh&°F) (BtuW or perimeter (ft) (Bluh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Val Blk Wall,Stucco Bd 0.109 n 3.15 Z02 0 0 0 0 0 0 0 0 G Impact,Clear Lowe 0.650 n 18.85 11.92 0 0 0 0 0 0 0 0 W Blk Wall,Stoop 6R 0.109 ne 3.15 2.02 0 0 0 0 36 36 115 73 Impact Clear Low-e 0.580 ne 16.82 27.37 0 0 0 0 0 0 0 0 11 ImpactClear Low�e 0.580 ne 16.82 2225 0 0 0 0 0 0 0 0 Blk Wall,Stu 000 FAQ 0.109 se. 3.15 2.02 0 6 0 0 77 68 214 137 Impact Clear Lowe 0:580" se 16.82. 15.96. 0 0. 0 0 0 0 0 0 Impact Clear Lowe 0.58,0 se 16.82 21.72 0 0 0 0 0 0 0 0 Impact Clear Lowe, 0.580 se 16.82 20.64 0 0 0 0 9 2 151 186 Door,!nd sctype 0.127 se 3.69 3.73 0 0 0 0 0 0 0 0 Blk Wall,Stucco EA 0.109 sw 3.15 2.02 57 57 179 114 0 0 0 0 Impact Clear Low-e 0.580 sw 16.82 21.46 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.580 sw 16.82 13.37 0 0 0 0 0 0 0 0 Impact Clear Lowe 0.650 sa 18.85 21.98 0 0 0 0 0 0 0 0 Impact TEMP,OBSC 0.580 sw 16.82 25.11 0 0 0 0 0 0 0 0 BIk Wall,Sfucoo EM 0.109 nw 3.15 2.02 0 0 0 0 0 0 0 0 Irilpacf Clear Lowe 0.580 nw 16.82 2225 0 0 0 0 0 0 0 0 Impact ClearLcvve 0.580 my 16.82 2225 0 0 0 0 0 0 0 0 Impact;Clear Low-e 0.580 nw 16.82 .2225 0 0 0 0 0 0 0 0 ImpackClear•Lowe 0.650-Inv 18.85 21.70 0 0 0 0 0 0 0 0 P Frm Wall,I&Gyp.B 0.101 2.94 1.09 0 0 0 0 0 0 0 0 C Mq-Shngl kwf,R. 0.034 - 0.94 0.76 42 42 39 32 129 129 121 98 F On Grade Depth,Tile 0.989 - 28.68 0.00 42 7 201 0 129 14 402 0 6 c)AED exc rsfon -8 41 Envelope loss/gain 418 138 1002 536 12 a) Infiltration 116 32 231 65 b) Room ventilation 0 0 0 0 13 Internal gains: Oosrpants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines6 to 13) 1534 170 1234 600 Less exfemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 46 14 20 6 14 Subtotal 580 184 1253 606 15 Duct loads 32o/a 379/. 185 67 321/o 37% 399 222 Total mom load 764 251 1652 828 Air required(cm) 381 12 82 41 Calculations approved bVACCAto meet all requirements of Manual J 8th Ed. A, -�.r- wr7gF.tso/Ft- 2021-Nov-1113:33:35 RightSute®Universal 202121.0.08RSU27054 Page ...oft HVAQ5313 S 25th St Thomas Res PSL Prop.rup Calc=MJ8 Front Door faces:N Air Calcs, LLC Ri ht-JO Worksheet Job: 1282 House Date: Jul 15,2020 By: Vicki Lynne Nisa Air Callas, LLC 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.860.8413 Email:viddlyrne@aircalcs.com 1 Room name Master Bedroom 2 Exposed cell 33.4 ft 3 Room height 9A It heaU000l 4 Room dimensions 1.0 x 216.5 It 5 Room area 216.5 IF Ty Construction U-value Or HTM Area (ft� Load Area Load number (Btuhill-T) (Btumn or perimeter (ft) (Bhih) or perimeter Heat Cool Gross N/P/S Heat Cool Gross NrP/S Heat Cool 6 Blk Wall,StiJmo Ext 0.169 n 3.15 2.02 80 41 130 M r. G Impact,ClearLow-e 0.650 n 18.85 11.92 39 0 726 459 WI - Blk Wall,Stucco EA 0.109 ne 3.15 2.02 0 0 0 0 Impac,ClearLowe 0.580 ne 16.82 27.37 0 0 0 0 Impact Clear Low-e0.580 ne 16.82 2225 0 0 0 0 Blk Wall,Stucoo E)d 0.109 se 3.15 2.02 0 .0 0 0 Impact Clear Lowe 0.580 `se 16.82 15.96 0 0 0 0 Impact Clear.Lowe 0.580 se- 16.82 21.72 0 0 0 0 Impac,ClearLowe, 0.580 sa 16.82 20.64 0 0 0 0 Door,%W sctype - 0.127 se 3:69 3.73 0 0 0 0 Blk Wall,Stuob EA 0.109 sw 3.15 2.02 169 138 435 278 Impact Clear Low-e 0.580 sw 16.82 21.46 31 4 525 669 Impact Clear Lowe 0.580 sw 16.82 13.37 0 0 0 0 Impact Clear Lowe 0.650 sw 18.85 21.98 0 0 0 0 Impact TEMP,OBSC 0.580 sw 16.82 25.11 0 0 0 0 Blk Wall;Stian Ext- 0.109 nw 3.15 2.02 66 43 135 86 Impad(ClearLow-e 0.580 nw 16.82 2225 0 0 0 0 Impac,Clear Lowk 0.580 nw- 16.82 2225 0 0 0 0 Impac,ClearLowe- 0.580 nw, 16.82 22.25 23 0 386 511 Impact Clear Lowe. 0.650 _rrv. . 18.85 21.70 0 0 0 0 P Frm Wall,1}2"Gyp.B 0.101 - 2.94 1.09 0 0 0 0 C Attiq Shngl Roof,R 0.034 - 0.94 0.76 217 217 203 165 F On Grade Depth,Tile 0.989 - 28.68 0.00 217 33 958 0 6 c)AED exarsion 161 Envelopelosslgain 3498 2413 12 a) Infiltration 642 179 b) Room ventilation 0 0 13 Internal gains. Occupants@ 230 0 0 Appliances/other 500 Subtotal(lines 6 to 13) 4140 3093 Less exlemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 4140 3093 15 Ductloads 329%1 37% 1319 1132 Total room load 5459 4225 Air required(dm) 269 208 Calculations approved by AC CAtomeetall requirements of Manual J 8th Ed. _ �- wrtghtscwm- 2021-Nov1113:33:35 """'"" Right Sute®Universal 2021 21.0.08 RSU27054 Page 9 ...oft HVAC15313S25thSt Thomas Res PSLPropxup Calc=MJ8 FrontDoorfaces:N Duct System Summary Job: Air•Calks, LLC Y � Jul 1 Date: Jul 5,zozo House By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beads,FL32966 Phone:772.800.8413 Email:viddlyrne@aircalcs.com Project • • For. Thomas Residence,Air Conditioning Unlimited,LLC 5313 S 25th St,Fort Pierce,FL 34981 Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.70 in H2O 0.70 in H2O Supply/return available pressure 0.509/0.191 in H2O 0.509/0.191 in H2O Lowest fricti on rate 0.149 in/100ft 0.149 in/100ft Actual airflow 1400 cfm 1400 cfm Total effective length(TEL) 469 ft SupplyBranch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (clml) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bat,2 h 726 43 23 0.232 4.0 Ox 0 VIFx 19.3 200.0 st1 Bed 2 h 2830 168 105 0.227 7.0 Ox 0 VIFx 24.3 200.0 st1 Bed 3 h 3070 182 127 0.149 8.0 Ox 0 VIFx 41.2 300.0 st4 Diring Room h 2190 130 111 0.243 7.0 Ox 0 VIFx 9.4 200.0 st3 Family Room c 2823 127 167 0.155 8.0 Ox0 VIFx 29.4 300.0 st4 FamilyRoonrA c 2823 127 167 0.153 8.0 Ox0 VIFx 33.8 300.0 st4 Foyer h 1146 68 36 0.213 5.0 OX 0 VIFX 38.9 200.0 s12 Kltdlen/Nook c 1698 39 100 0.237 6.0 Ox 0 VIFx 14.4 200.0 st1 KitchenNock-A c 1698 39 100 0.153 6.0 Ox0 VIFx 32.3 300.0 st4 KitchervNook B c 1698 39 100 0.150 6.0 Ox 0 VIFx 40.1 300.0 st4 Landry h 1064 63 52 . 0.244 5.0 Ox 0 VIFX 8.9 200.0 st3 Living Room c 2053 58 121 0.212 7.0 OX 0 VIFx 39.6 200.0 st2 Living Room-A c 2053 58 121 0 0 Ox 0 VIFx 0 0 Master Bath h 1652 98 49 0.212 6.0 Ox 0 VIFx 39.8 200.0 st2 Master Bedroom h 2729 162 125 0.205 7.0 Ox0 VIFx 48.6 200.0 st2 MasterBedroom•A h 2729 162 125 0.213 7.0 OxO VIFx 39.0 200.0 st2 wlc h 764 45 15 0.215 4.0 Ox0 VIFx 36.8 200.0 st2 wtr clsc h 1275 76 36 0.210 5.0 Ox 0 VIFx 42.5 200.0 st2 -�- wrightsoft® 2021-Nov-11 13:33:36 RightSute@ Universal 202121.0.08RSU27054 Pagel ._ofHVAC\5313S25tiSt Thomas Res PSLProp.rup Calc=MJB Front Door faces:N SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 PeakAVF 513 661 0.149 618 14.0 0 'x 0 VinIFIX st1 st1 PeakAVF 762 889 0.149 832 14.0 0 x 0 VinlFlx st2 PeakAVF 667 506 0.205 850 12.0 0 x 0 VinIFIX st3 PeakAVF 193 164 0.243 552 8.0 0 x 0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) M FR (fpm) (in) (in) Opening(in) Matl Trunk rb4 Ox0 368 264 127.9 0.149 469 12.0 Ox 0 VIFx rt1 rb3 Ox0 182 127 85.4 0.224 521 8.0 Ox 0 VIFx rt1 rb2 Ox0 168 105 76.9 0.248 480 8.0 Ox 0 VIFx rt1 rb1 Ox0 905 1062 83.2 0.229 601 18.0 Ox 0 VIFx rt1 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk rt1 PeakAVF 1622 1559 0.149 744 20.0 0 x 0 VInIFIx Boldidalk values have been manually overridden -�- wrightsoft- 2021-Nov-11 13:33:36 Right Sute®Uriversal 2021 21.0.08 RSU27054 Page 2 +� ...oft M/AQ5313S25thSt Thomas Res PSLProp.np Calc=MJ8 FrontDoorfaces:N it Manual S Compliance Report Job: Jul1 _ 1282 Air�Calcs, LLC P � p Date: Ju115,zozo House. By. Vicki Lynne Nisa Air Calcs, LLC 7550 Hidden Hammock Ln,Vero Beach,FL32966 Phone:772.800b413 Email:viddlyme@aircahs.com Project • • For. Thomas Residence,Air Conditioning Unlimited,LLC 5313 S 25th St,Fort Pierce,FL 34981 Cooling-Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 29260 Btuh . Entering coil DB: 76.5°F Outdoor design WB: 77.4°F Latent gain: 7063 Btuh Entering coil WB: 63.7°F Indoor design DB: 75.07 Total gain: 36323 Btuh Indoor RH: 50% Estimated airflow: 1400 cfrn Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer: Lennox Model: ML14XC1SO42-230A**+CBA27UHE-042-230*++TDR Actual airflow. 1400 cfm Sensible capacity: 29400 Btuh 100%of load Latent capacity: 12600 Btuh 178%of load Total capacity: 42000 Btuh 116%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 41.0°F Heat loss: 29894 Btuh Entering coil DB: 68.6°F Indoor design DB: 70.OoF Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Elecstrip Manufacturer: Model: Actual airflow 1400 cfm Output capacity: 8.1 kW 92%of load Temp.rise: 50 °F Meets all requirements ofACCA Manual S. - wrightsoft® 2021-Nov-1113:33:36 �- ••��r��. m—o , RigMSute®Uriversal 2021 21.0.0E RSU27054 Page 1 ...oftHVAQ5313S25thSt Thomas Res PSLProp.np Calc=MJ8 FrontDoorfaces:N I - l N Leve11 I — I I 1 S '. is . ..®a .• i�� lnnp Paea i 1 I _ '8M ems I f r o i L eao j ar. r ca<• qet Job#: 1282 Air Calcs, LLC Scale: 1 : 243 Performed by Vicki Lynne Nisa for: Page 1 Thomas Residence 7550 Hidden Hammock Ln Right-Suite®Universal 2021 5313 S 25th St Vero Beach, FL 32966 21.0.08 RSU27054 Fort Pierce,FL 34981 Phone:772.800.8413 2021-Nov-11 13:33:52 vickilynne@aircalcs.com •••25th St Thomas Res PSL Prop.rup