HomeMy WebLinkAboutTruss Engineering07 4451 ST. LUCIE BLVD -r
FORT PIERCE, FL 34946
} I F
PH: 772-409-1010
FX: 772-409-1015
www.AlTruss.com
1100
Ago
TRUSS ENGINEERING
BUILDER: HABITAT SLC
PROJECT. BROOKLINE AVENUE
COUNTY: ST LUCIE
MLOT/BLK/MODEL: MODEL:THREE BEDROOM GAR R
JOB#: 84915
0
® MASTERM CHHS313
v
m< OPTIONS: NO OPTIONS
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
= A-1 ROOF These truss designs rely on lumber values established by others.
'A#=TRUSSES
A FLORIDA CORPORATION
RE: Job 84915 A-1 Roof Trusses
4451 St Lucie Blvd
Site Information: Fort Pierce, -FL 34946
Customer Info: HABITAT ST. LUCIE COUNTY Project Name: BROOKLINE AVENUE
Lot/Block: Model: THREE BEDROOM
Address: LAKWOOD PARK FT PIERCE, FL Subdivision:
City: County: St Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC 7th Ed. 2020 Res. / TPI 2014 Design Program: Alpine Engineered Products
Wind Code: ASCE 7-16 Wind Speed: 160
Roof Load: 40.d psf Floor Load: 0.0 psf
This package includes 30 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G 1 5-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
1
2645
A01
219/21
13
2651
B01
2/9/21
25
2601
CJ7
2/9121
2
2581
A02
2/9/21
14
2592
B02
2/9121
26
2606
HJ5
2/9/21
3
2582
A03
2/9/21
15
2593
B03
2/9/21
27
2607
HJ8
219/21
4
2583
A04
2/9/21
16
2594
B04
2/9/21
28
2603
J7
2/9/21
5
2641
A05
2/9/21
17
2609
B05
2/9/21
29
2604
A
219/21
6
2638
A06
2/9/21
18
2595
B06
2/9/21
30
2605
J8B
2/9/21
7
2616
A07
2/9/21
19
2596
B07
2l9/21
31
STDL01
STD. DETAIL
2/9121
8
12613
A08
2/9/21
20
12597
B08
2/9/21
32
STDL02
STD. DETAIL
2/9/21
9
2621
A09
2/9/21
21
2648
B09
2/9/21
33
STDL03
STD. DETAIL
2l9/21
10
2635
A10
2/9/21
22
2598
CA
2/9121
34
STDL04
STD. DETAIL
2/9/21
11
2629
All
2/9/21
23
2599
CJ3
2/9/21
35
STDL05
STD. DETAIL
2/9/21
12
2632
Al2
2/9/21
24
2600
CJ5
2/9/21
36
STDL06
STD. DETAIL
219121
The truss drawing(s) referenced have been prepared byAlpine Engineered Products, Inc. under my direct supervision based on the parameters provided byA-1 RoofTrusses, Ltd.
Truss Design Engineer's Name: Rama Pranav Kristam
My license renewal date for the state of Florida is February 28,2021.
NOTE: The seal on these drawings indicate acceptance of professional engineering
responsibility solely forthe truss components shown.
The suitability and use of components for any paitksularbuildIng Is the responsibility of the building
designer, perANSVrPI.1 Sea 2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction
documents (also referred to attires as'Structural Engineering Documents) provided by the Building
Designer indicating the nature and character of the work
The design criteria therein have been transferred.to Rama Pranav Kristam PE by [Al Roof Trusses or
specific location]. These TDDs (also referred to at times as'Structural Delegated'
Engineering Documents) are specialty structural component designs and may be part of the project's
deferred orphaned submittals. As aTruss Design Engineer(ie, Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional engineering
responsibilityforthe design of the single Truss depicted on the TDD only. The Building Designer is
responsible forand shall coordinate and review the TDDs for
compatbilitywith theirwritten engineering requirements. Please review all TDDs and all related notes.
Page 1 of 2
Rama Pranav Kristam, P.E.
4451 St Lucie Blvd. Suite 201
Fort Pierce, FL 34946
Lumber design values are in accordance with ANSlfTPI 1-2014 section 6.3 R ,
A�� ROQF These truss designs rely on lumber values established by others.
TRUSSES
A FLORIDA CORPORATION
RE: Job CHHS3B
No.
Seq #
Truss Name
Date
37
STDL07
STD. DETAIL
2/9/21
38
STDL08
STD. DETAIL
2/9/21
39
STDL09
STD. DETAIL
2/9/21
40
STDL10
STD. DETAIL
2/9/21
41
STDL11
STD. DETAIL
219/21
42
STDL12
STD. DETAIL
2/9/21
43
STDL13
STD. DETAIL
2/9/21
44
STDL14
STD. DETAIL
2/9/21
45
STDL15
STD. DETAIL
2/9/21
46
STDL16
STD. DETAIL
2/9/21
Rama Pranav Mstam, P.E.
Page 2 of 2 488906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
Jot) I cuss I Russ I ype Ury I Hly UG/UH/1UL'I 2645
CHHS313 A01 I HIPS 1 1
16'4° 11'8"
=5X6 =3X4
16'4"
G H Es 5XI
_ I
T ,2
4 p
io 3X6 F 4X6
:3X4E >(a
K Z3X6
c1 5X4 D
go4X4 (a) L:3X4
=4X6(C6 B
_ 5Mg•
=3X6 C6Ro S R Q P 0 1113 N
=3X4 =5X6 -=3X8 =4X12 =3X6
SEAj, PLATE REQ. SEAT PLATE REQ.
IL-'6 354" 7'6"
�- 2'6" 1 44'4"
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.145 L 368 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.312 L 171 240
B 1686 /- /- /1060 1783 /178
BCDL: 10.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.045 L - -
N 2107 /- /- /1390 /899 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.076 L
Wind reactions based on MWFRS
Des Ld: 40.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2
B Br Width = 8.0 Min Re 1.5
q
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0. 0.681
N Brg Width = 8.0 Min Req 1.7
Load Duration: 1.25 BCDL: 5.0 psf
Bearings B & N are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
Max BC CSI: 0.773
Bearings B & N require a seat plate.
C&C Dist a: 4.43 ft
Max Web CSI: 0.832
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 13.00
ft
Wgt: 241.5 Ibs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver. 20.01.01A.0724.12
B - C 383 -937 G - H 1849 -2088
Lumber
A - B 52 0 H -1 1488 -1539
C - D 1754 - 2437 I - J 1461 -1689
Top chord: 2x4 :SP 2400f-2.OE + SP M-31:;
D - E 1980 -2639 J - K 1437 -1704
T2 2x4 SP M-30; T3,T4 2x4 SP #2;
E - F 1840 -2270 K - L 896 -1187
Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP M-30;
F - G 1861 -2249 L - M 863 -1059
B3 2x4 SP 2400f-2.OE + SP M-31;
Webs: 2x4 SP #3; W7 2x6 SP #2;
Lt Slider: 2x6 SP #2; block length = 2.750'
Maximum Bot Chord Forces Per Ply (Ibs)
Rt Slider: 2x6 SP #2; block length = 2.750'
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B - S 2220 -1485 P - O 1079 -725
(a) Continuous lateral restraint equally spaced on
S - R 2535 -1795 O - N 1079 -725
member.
R - Q 2534 -1796 N - L 1178 - 779
Q - P 1980 -1491 L - M 1083 - 811
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 16.33 28.00
BC 75 0.00 44.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B - C
2400 - 2442
Q - H
344 - 99
D - S
449 -453
H - P
825 - 691
S - E
449 -222
P -1
218 -47
E - Q
424 - 544
P - K
2069 -1864
G - Q
372 - 88
K - N
1918 -1898
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineers
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. -The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrinht Q 2016 A-1 R-f Tn,ssec - Renmduntinn of this d-ment. in anv form. Is nrohihited without the written nennission of A-1 Roof Tnisses.
Rama Pranav Kristam, P.E.
488906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
ion 1 cuss I cuss I ype wry I rly uuuarcuc r
2581
CHHS313 A02 HIPS 1 1
A
18W TV' 18W
5X8
G
=5X6
H
T 12
4 so3X4F I �jt 4
ago
o3X4D 3X6E (a) K 1112X4
to =3)g(�g) a
C
4X6(C6 L
-1sps�
T S R Q P O N M= X6
1111.5X3 =3X4 =5X6 =3X4 =3X8 =3X6
SEAj PLATE REQ. SEAT PLATE REQ.
35'4" 7'6"I AL
�{
�- 2,6"
Loading Criteria (psf)
TOLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NC13CLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 4.43 ft
Loc. from endwall: not in 13.0(
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.OE +
SP M-31; T2 2x4 SP M-30;
Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP #2;
B3 2x4 SP M-30;
Webs: 2x4 SP #3; W8 2x6 SP #2;
Lt Slider: 2x4 SP #3; block length = 1.750'
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 18.33 26.00
BC 72 0.00 44.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
44'4"
=-3X6(A1)
i
1
Code / Misc Criteria
Defl/CS1 Criteria
♦ Maximum Reactions (Ibs)
Code:FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.147 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
Rep Factors Used: Yes
VERT(CL): 0.306 F 999 240
T 1674 /- /- /1049 /777 /196
FT/RT:10(0)/10(10)
HORZ(LL): 0.034 M - -
M 2121 /- /- /1388 /887 /-
Plate Type(s):
HORZ(TL): 0.075 M - -
Wind reactions based on MWFRS
WAVE
Creep Factor: 2.0
T Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.999
M Brg Width = 8.0 Min Req = 2.5
Max BC CSI: 0.985
Bearings T & M are a rigid surface.
Max Web CSI: 0.738
Bearings T & M require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
t
Wgt:233.1 Ibs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 20.01.01A.0724.12
B - C 477 -1256 G - H 1449 -1528
A - B 52 0 H -1 1433 -1659
C - D 1537 -2346 I - J 867 -1098
D - E 1805 - 2615 J - K 860 -1110
E - F 1817 - 2575 K - L 870 -1224
F - G 1672 -2010
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
T - B
1209 - 360
P - O
1854 -1173
T - S
2173 -1330
O - N
988 - 606
S - R
2196 -1352
N - M
988 - 606
R - Q
2337 -1529
M - L
1216 - 759
Q - P
2336 -1529
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - C
1134 -1271
G - O
530
-498
S - D
603 -575
O - H
262
-75
D - R
450 -408
0-1
822
-719
R- F
353 0
I- M
1921
-2078
F - P
513 -630'
M - K
578
-452
G - P
530 -226
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for.the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 1 488906
use of the Truss, including handling, storages Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C rmht0201E A-1 Roof Tn.---Renrodnctinn of this dnannent. in anv fnon. is nmhihited votht"d the written narmiecinn of A-1 Ronf'r sac.
CHHS3B A03 HIPS ype 1ty 11y UL/UulzuZ
2582
20'4" 1 3'8" 1 20'4"
e5X6 =6X6
G H
T 12
4 � �3X4F "1113X4
J�3X6
i� �3X4D �4X6E (a) 4X6
�(C6)A4X6 L
T S R Q P O N 1113 M
f P �� i
LATE REC.
2,6„
1111.5X4 =3X4 =5X6 =3X4 =3X4 =3X6 =4X4
Loading Criteria (pso
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 40100
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 4.43 ft
Loc. from endwall: not in 13.0(
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.0E +
SP M-31; T3 2x4 SP #2;
Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP M-30;
B3 2x4 SP #2;
Webs: 2x4 SP #3; W8 2x6 SP #2;
Lt Slider. 2x4 SP #3; block length = 1.750'
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 20.33 24.00
BC 61 0.00 44.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
35'4"
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
44'4"
SEAT PLATE REQ.
7'6" �{
i�
3X6(A1)
Defi1CS1 Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc Udefl U# Gravity Non -Gravity
VERT(LL): 0.276 Q
999 360 Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0.654 Q
636 240 U 1686 A A /1044 /782 /214
HORZ(LL): 0.063 G
- - M 2107 A A /1365 /879. A
HORZ(TL): 0.151 G
- - Wind reactions based on MWFRS
Creep Factor: 2.0
U Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.817
M Brg Width =1 .0 Min Req = 2.5
Max BC CSI: 0.995
Bearings U & M are a rigid surface.
Bearings U & M require a seat plate.
Max Web CSI: 0.784
Maximum Top Chord Forces Per Ply (Ibs)
Wgt:230.3lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 20.01.01A.0724.12 B - C 521 -1332 G - H 1425 -1603
A- B 52 0 H- I 1402 -1745
C - D 1439 - 2339 I - J 565 - 676
D - E 1759 - 2705 J - K 557 - 741
E - F 1776 - 2655 K - L 904 -1135
F - G 1446 -1777
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
U - B
1282 -400
Q - P
1603
- 893
U - T
2175 -1251
P - O
1271
- 754
T - S
2201 -1276
O - N
1271
- 754
S - R
2326 -1428
N - M
1055
- 697
R - Q
2326 -1428
M - L
1154
- 778
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B - C
992 -1183
H - P
192 - 52
T - D
579 - 576
P -1
725 - 517
D - S
477 - 369
I - N
1234 -1224
S-F
514 -42
N-K
1432 -981
F - Q
822 - 959
K - M
1600 -1920
G-Q
421 -218
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Mstam, P.E.
- responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field � # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined In TPI-1.
Cnnvrinht a 2nte A-1 Roof Tnrecr_c — Renroduotion of this donrmnnt. in anv form. is nmhlhitnd with -I this written nermiscion of A-1 Rant Tmcses.
Job I russ I russ I ype wry I rly u/ruarzuz 1 2583
CHHS313 A04 HIPS 1 1
it
22'
22' —1
T
io
L6
60
=3X6(A1)
III1.5X3 =3X4 =bX6 =3xb =3Xb =4X4
,%T, PLATE REQ. SEAT PLATE REQ.
I A 354" 7'6" -{
2,6„ 1 44 4" 1
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res. PP Deflection in loc Udefl L/# Gravity
Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014 VERT(LL): 0.150 Q
999 360 Loc R+ / R- / Rh
/ Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes VERT(CL): 0.310 Q
999 240 S 1686 /- /-
/1032 1782 /229
BCDL: 10.00 Risk Category: II
FT/RT:10(0)/10(10) HORZ(LL): 0.031 M
- - L 2107 /- /-
/1350 /879 /-
EXP: C Kzt: NA
Plate Type(s): HORZ(TL): 0.067 M
- Wind reactions based on
MWFRS
Des Ld: 40.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
S Brg Width = 8.0
Min Req = 1.5
NCBCLL: 10.00 TCDL: 5.0 psf
p
Max TC CSI: 0.631
L Brg Width = 8.0
Min Req = 2.5
Load Duration: 1.25 BCDL: 5.0 psf
Bearings S & L are a rigid
surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
Max BC CSI: 0.994
Bearings S & L require a
seat plate.
C&C Dist a: 4.43 ft
Max Web CSI: 0.778
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 13.00
ft Wgt: 230.3 Ibs
Chords Tens.Comp.
Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 20.01.01A.0724.12 B - C 576 -1470
F - G 1266 -1676
Lumber
A- B 52 0
G- H 1241 -1671
C - D 1422 -2435
H -1 658 -931
Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.0E +
D - E 1578 -2594
I - J 645 - 995
SP M-31; T3 2x4 SP #2;
E - F 1599 -2550
J - K 915 -1147
Bot chord: 2x6 SP 2400f-2.OE; B2 2x4 SP M-30;
B3 2x4 SP #2;
Webs: 2x4 SP #3; W8 2x6 SP #2;
Maximum Bot Chord Forces Per Ply (Ibs)
Lt Slider: 2x4 SP #3; block length = 1.750'
Chords Tens.Comp.
Chords Tens. Comp.
Bracing
S - B 1414 -452
O - N 1400 -753
(a) Continuous lateral restraint equally spaced on
S - R 2272 -1241
N - M 1400 -753
member.
R - Q 2292 -1261
M - L 1064 -708
Q - P 2215 -1249
L - K 1160 - 789
Purlins
P - O 2214 -1250
In lieu of structural panels or rigid ceiling use purins
to laterally brace chords as follows:
Maximum Web Forces Per Ply (Ibs)
Chord Spacing(in oc) Start(ft) End(ft)
Webs Tens.Comp.
Webs Tens. Comp.
BC 58 0.00 44.33
Apply purlins to any chords above or below fillers
B - C 917 -1139
G - O 606 -307
at 24" OC unless shown otherwise above.
R - D 529 -475
O - H 302 -259
D - Q 268 -230
H - M 1034 -1031
Loading
Q - F 488 -16
M - J 1585 -1080
Truss passed check for 20 psf additional bottom chord
F - O 774 -881
J - L 1633 -1960
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid.. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn .
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kfstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building.Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field. # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
('—winht 0 201fi A-1 Roof Tnisses — Renrodintion of this dnorrment. in env inns. is nmhihiled without the written mrmiscinn M A-1 Ronf Trtmen.
Job I cuss Truss I ype rlty I Ply 02/09/2U21
CHHS3B A05 HIPS 1 1 2641
T
1
,a.
20'6" i3'4" 1 20'6"
ea5X6 =6X6
F G
=3X4 =H0308 -3X4 =3X4 =3X6 =4X4 1113X6`
S,%T. PLATE REQ. SEAT PLATE REQ.
f 35'4" 7-6"
44'4" _1
=3X6(A1)
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl L/# Gravity
Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014 VERT(LL): 0.303 P
999 360 Loc R+ / R- / Rh
/ Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes VERT(CL): 0.694 P
600 240 S 1520 A A
/880 /684 /183
BCDL: 10.00 Risk Category: II
FT/RT:10(0)/10(10) HORZ(LL): 0.053 F
- - L 2112 A A
/1361 /888 A
EXP: C Kzt: NA
Plate Type(s): HORZ(TL): 0.130 F
- - Wind reactions based on
MWFRS
Des Ld: 40.00 Mean Height: 25.00 ft
WAVE, HS
Creep Factor: 20.
S Br Width = 8.0
9
Min Re 1.5
q =
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0.873
L Brg Width = 8.0
Min Req = 2.5
Load Duration: 1.25 BCDL: 5.0 psf
Max BC CSI: 0.994
Bearings S & L are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
Bearings S & L require a
seat plate.
C&C Dist a: 4.43 ft
Max Web CSI: 0.793
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 13.00
ft Wgt:219.1 Ibs
Chords Tens.Comp.
Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 20.01.01A.0724.12
A- B 149 -655
F - G 1477 -1628
Lumber
B - C 1989 -2698
G - H 1456 -1772
C - D .1881 -2611
H - I 577 - 731
Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE +
D - E 1501 -1806
I - J 773
-130
SP M-31; T3 2x4 SP #2;
E - F 1501 -1806
899
J - K 899 -1130
Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:;
B2 2x4 SP M-30; B3 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Lt Slider: 2x6 SP #2; block length = 2.750'
Chords Tens.Comp.
Chords Tens. Comp.
Bracing
S - R 2461 -1681
O - N 1301 -795
(a) Continuous lateral restraint equally spaced on
A - S 666 -136
N - M 1301 -795
member.
R - Q 2315 -1520
M - L 1085 -726
Q - P 2315 -1520
L - K 1145 - 773
Purlins
P - O 1628 -941
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Maximum Web Forces Per Ply (Ibs)
Chord Spacing(in oc) Start(ft) End(ft)
Webs Tens.Comp.
Webs Tens. Comp.
TC 24 20.50 23.83
BC 61 0.00 44.33
S - B 2000 - 2270
G - O 183 - 52
Apply purlins to any chords above or below fillers
C - R 233 -54
O - H 720 -505
at 24" OC unless shown otherwise above.
R - E 381 -34
H - M 1242 -1220
E - P 811 - 908
M - J 1485 -1031
Loading
F - P 462 -271
J - L 1613 -1923
Truss passed check for 20 psf additional bottom chord
live load in areas with 42%high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" torn.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC;the.IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling; storage. Installation and bracing shall be the responsibility of the Building Designer and Contractor.'AII notes set out in the TDD and the practices and 4451 St. Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
C.novdaht 0 2o16 A-1 Ronf Tnvcaac - Renrod-11- of this domirn-t. in anv form. is nmhihited without the written nermission of A-1 Roof Tmeses.
Job I ruSS I Russ I ype
CHHS313 A06 HIPS
18'6°
5X8
F
ty 1y UZ1Uy1ZUZI
T4" 18'6" -
=5X6
G
=3X4 =4X6 =3X4 =-3X8 =3X6 -5xb
SEAT PLATE REQ.
{-1 (iA 354"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 40.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 4.43 ft
Loc. from endwall: not in 13.0(
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.OE +
SP M-31; T5 2x4 SP M-30;
Bot chord: 2x4 SP M-30; B1 2x4 SP 2400f-2.OE +
SP M-31;
Webs: 2x4 SP #3; W6 2x6 SP #2;
Lt Slider: 2x6 SP #2; block length = 2.750'
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 18.50 25.83
BC 75 0.00 44.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
44'4"
Defl/CSI Criteria
PP Deflection in loc Udefl L14
VERT(LL): 0.190 E 999 36
VERT(CL): 0.400 E 999 24i
HORZ(LL): -0.055 B - -
HORZ(TL): 0.118 B -
Creep Factor: 2.0
Max TC CSI: 0.814
Max BC CSI: 0.742
Max Web CSI: 0.731
Wgt: 221.2 Ibs
VIEW Ver: 20.01.01A.0724.12
SEAT PLATE REQ.
TW
2638
3X6(A1)
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
R 1508 /- /- /885 /679 /165
L 2126 /- /- /1385 /895 /-
Wind reactions based on MWFRS
R Brg Width = 8.0 Min Req = 1.5
L Brg Width = 8.0 Min Req = 2.5
Bearings R & L are a rigid surface.
Bearings R & L require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 245 - 707 F - G - 1493 -1548
B - C 1958 -2659 G - H 1480 -1681
C - D 2006 - 2575 H -1 866 -1108
D - E 2017 - 2545 I - J 843 -1112
E - F 1742 -2047 J - K 872 -1227
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
R - Q 2428 -1654 O - N 1887 -1235
A-R 711 -219 N-M 1021 -651
Q - P 2337 -1640 M - L 1021 - 651
P - O 2337 -1640 L - K 1218 - 758
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
R - B
1877 - 2165
F - N
536
- 508
C - Q
207 - 29
N - G
244
- 83
Q - E
232 -40
N - H
798
-699
E - O
553 -566
H - L
1955
-2097
F - O
570 -263
L - J
580
-454
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid: As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of.the professional engineedri
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitabilityand use of this Truss for any Building lathe Rama Pranav Kristam, P.E. .
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the-TDD and any field- # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDDandthe practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
rnvrimht 0 2016 A-1 RnnfTm-Renrndurtinn ofthN dmiment. in anv fnrm. is nmhihHnd wlthnut tha written mnnicsinn of A-1 Rnnf Tntecr..c.
Job
CHHS3B
I Russ I Russ I ype
A07 HIPS
ty 11y IO2/09/2021
2616
fi
16'6° 11'4" -}16'6°
=5X6 Ill1.5X4 =5X6
E F G
12'
4 p
503X6_
Ao3X4 B
'-3X6(C6
=3X6(86) Q P O N M L
1111.5X3 =V4 =H0308 =3X8 =H0308 =4X4
4X6
H�1--3X6
SEAT PLATE REQ. SEAT PLATE REQ.
r 44'4"
J=3X6(A1)
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc Udefl
L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.205 P 999
360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.430 P 969
240 R 1520 /- /- /896 /685 /147
BCDL: 10.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL):-0.068 B -
- K 2112 /- /- /1387 /900 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.144 B
- Wind reactions based on MWFRS
Des Ld: 40.00 Mean Height: 25.00 ft
WAVE, HS
Creep Factor: 20.
R Br Width = 8.0 Min Re 1.5
9 q =
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0.804
K Brg Width = 8.0 Min R. = 2.5
Load Duration: 1.25 BCDL: 5.0 psf
"
Max BC CSI: 0.997
Bearings R & K are rigid surface.
Spacing: 24.0 MWFRS Parallel Dist: h/2 to h
Bearings R & K require a seat plate.
i
C&C Dist a: 4.43 ft
Max Web CSI: 0.970
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 13.00
ft
Wgt: 214.2 Ibs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 18
VIEW Ver. 20.01.01A.0724.12
A- B 496 -922 F - G 1936 -2044
Lumber
B - C 2131 -2683 G - H 970 -1094
C - D 20-2545 H - I 945 -11
Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE +
D - E 2081 -2535 I - J 915 -1139
SP M-31; T3,T4 2x4 SP #2;
E - F 1936 -2044
Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:;
B2 2x4 SP M-30; B3 2x4 SP #2;
Webs: 2x4 SP #3; W6 2x6 SP #2;
Maximum Bot Chord Forces Per Ply (Ibs)
Lt Slider: 2x6 SP #2; block length = 2.750'
Chords Tens.Comp. Chords Tens. Comp.
Purlins
R - Q 2470 -1832 N - M 1506 -1123
In lieu of structural panels or rigid ceiling use purlins
A - R 913 -464 M - L 1506 -1123
to laterally brace chords as follows:
Q - P 2475 -1839 L - K 1040 -707
Chord Spacing(in oc) Start(ft) End(ft)
P - O 2088 -1544 K - J 1135 -789
TC 24 16.50 27.83
O - N 2088 -1544
BC 56 0.00 44.33
Apply purlins to any chords above or below fillers
Maximum Web Forces Per Ply (Ibs)
at 24" OC unless shown otherwise above.
Webs Tens.Comp. Webs Tens. Comp.
Loading
R - B 1831 -1961 F - N 497 -281
Truss passed check for 20 psf additional bottom chord
Q - C 198 -144 N - G 820 -724
live load in areas with 42%high x 24"-wide clearance.
C - P 303 -188 G - L 1137 - 976
P - E 480 -184 L - I 1594 -1302
Wind
E - N 237 -164 I - K 1844 -1960
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER-), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 4 88906 -
use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Luae Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
C nvrinht M MIA A-1 Ronf Tntcsrs— R—cluntinn of this dom,mant.. in anv farm. is nmhihited wehnut the wridan namnission of A-1 RnnfTmsses.
Job I russ I russ t ype city Fly
CHHS313 A-08 HIPS 1 1
Uz1Ua1ZUz1 2613
14'6" 164"
255X8
III1.5X4
12
D
E -_
F
T
47oo
3X4 C
to
(a).
B
;�
A�3X4
P
O N
M L K
III1.5X3
=3X4=3X6
=3X10 =3X6=4X6
r ,
14'6"
G-�-4X6
(a) H Z3X4
J III3X6
SEAT PLATE REQ. SEAT P PT6BffQPLAT66ffi1P8l A��REQ.
35' 5,4„ -i ;F --
Loading Criteria (psq Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 40.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 5.0 psf
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
C&C Dist a: 4.43 ft
Loc. from endwall: not in 13.0(
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2; T1 2x4 SP 2400f-2.OE +
SP M-31;
Bot chord: 2x4 SP #2; B1 2x4 SP 2400f-2.OE +
SP M-31;
Webs: 2x4 SP #3; W6 2x6 SP #2;
Lt Slider: 2x6 SP #2; block length = 2.750'
Rt Slider: 2x6 SP #2; block length = 2.750'
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Plating Notes
All plates are 3X6(C6) except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 14.50 29.83
BC 71 0.00 44.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
44W
Deft/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.212 O 999 36
VERT(CL): 0.424 O 982 24
HORZ(LL): -0.058 B - -
HORZ(TL): 0.117 B -
Creep Factor: 2.0
Max TC CSI: 0.963
Max BC CSI: 0.964
Max Web CSI: 0.758
Wgt: 224.7 Ibs
VIEW Ver. 20.01.01A.0724.12
♦ Maximum Reactions (Ibs), or.=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
Q 1526 /- /-
/883 /708 /130
J 1842 /- /-
/950 1771 /-
J' 24 /- /-
/14 /3 /-
R 337 /-119 P
/160 /168 /-
Wind reactions based on MWFRS
Q Brg Width = 8.0
Min Req = 1.5
J Brg Width = 8.0
Min Req = 2.2
J Brg Width = 64.0
Min Req = -
R Brg Width = 8.0
Min Req = 1.5
Bearings Q, J, J, & R are a rigid surface.
Bearings Q, J, J, & R require
a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A - B 524 -838
E - F 2420 -2372
B - C 2335 - 2690
F - G 1568 -1580
C - D 2325 -2493
G - H 604 -267
D - E 2420 - 2372
H -1 657 - 724
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Q - P
2467 - 2052
M - L
1435 -1189
A - Q
835 - 504
L - K
1435 -1189
P - O
2468 - 2059
K - J
230 - 420
O - N
2320 -1939
J - R
619 -1069
N - M
2320 -1939
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
Q - B
1974 -2075
M - F
1140 -1059
P-C
213 -29
F-K
614 -586
C - O
211 - 250
K - G
1899 -1395
D- O
365 - 8
G- J
1526 -1728
D - M
145 - 348
H - R
623 - 593
E - M
740 -482
"WARNING" - Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates.shall.be used for the TDD to. be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field .. # 88906
use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lude Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C ovriaht 0) 2016 A-1 Rmf Trij.-- Renmdurlinn of thtc dna,ment. in anv form. is nmhihilnd withmit thn w rittnn nnnniesinn of A-1 Rnnf Tn,csr-s.
Job Truss Truss Type Qty I ply Uz/US/2uz1
CHHS3B A09 I HIPS 1 1 2621
i 11'11-11/16"
19'4" -1- 11'11-11/16"-�
12
4 p
T
`r 3X4 D
m3X6(C6)e3X4 v2l
rn m4X6A(C6)B C
-v
1 s 1Ti6.
=3X4
E=SYS F
N(a)
=3X6 1111.5X3
G H
(a)
= I
JZ3X4 =4X6(C6)
)
_L�3M4
U
T S R
Q P
O N
III1.5X3
=3X4 =H0308 =3X4
=3X8 =H0308
=3X4 1111.5X3
gE T
11 I /PLATE REQ.
Lq �}�
SEAT 1111T1 /116E"Q.
j1_
41'4"
6 T/)f6"
r
43'3-3/8"
6-v5/]6„
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc Udefl
L/# Gravity Non -Gravity
Speed: 160 mph
TCDL: 10.00 P
TPI Std: 2014
( ) VERT LL : 0.339 H 999
360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.684 H 714
244 B 1788 !- /- /1002 /822 /118
BCDL: 10.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.092 N -
- L 1788 /- /- /1002 /822 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.187 N -
- Wind reactions based on MWFRS
Des Ld: 40.00 Mean Height: 25.00 ft
WAVE, HS
Creep Factor: 2
B Br Width = 8.0 Min Re 2.1
NCBCLL: 10.00 TCDL: 5.0 psf
0.
Max TC CSI: 0.769
L Brg Width = 8.0 Min Req = 2.1
Load Duration: 1.25 BCDL: 5.0 psf
Bearings B & L are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
Max BC CSI: 0.989
Bearings B & L require a seat plate.
C&C Dist a: 4.43 ft
Max Web CSI: 0.999
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 6.50
Wgt: 232.4 Ibs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 20.01.01A.0724.12
A- C 667 -971 G - H 3786 -3944
C - D 2959 -3370 H -1 3788 -3946
Lumber
D - E 3135 - 3402 I - J 3133 - 3401
Top chord: 2x6 SP 2400f-2.OE; T2,T3 2x4 SP #2;
E - F 3766 -3927 J - K 2960 -3371
Bot chord: 2x4 SP M-30; B2 2x4 SP #2;
F - G 3786 -3944 K - M 669 -972
Webs: 2x4 SP #3;
Lt Slider: 2x4 SP #2; block length = 1.750'
Rt Slider: 2x4 SP #2; block length = 1.750'
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Bracing
(a) Continuous lateral restraint equally spaced on
A - B 1003 -675 R - Q 3950 -3465
member.
B - U 3068 -2608 Q - P 3194 -2738
U - T 3067 -2613 P - O 3194 -2738
Purlins
T - S 3195 -2742 O - N 3068 -2612
In lieu of structural panels or rigid ceiling use purlins
S - R 3195 -2742 N - L 3069 -2608
to laterally brace chords as follows:
Chord Spacing()n oc) Start(ft) End(ft)
Maximum Web Forces Per Ply (Ibs)
TC 24 11.97 31.31
Webs Tens.Comp. Webs Tens. Comp.
BC 54 0.00 43.28
Apply purlins to any chords above or below fillers
B - C 2487 -2647 H - Q 548 - 353
at 24" OC unless shown otherwise above.
U - D 178 -2 Q -1 896 -964
D - T 207 - 389 1-0 236 -1
Wind
E-T 236 0 O-J 210 -386
Wind loads based on MWFRS with additional C&C
E - R 878 -938 J - N 178 -3
member design.
R - F 584 -360 K - L 2487 -2646
Wind loading based on both gable and hip roof types.
F - Q 77 -71
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TOO represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the .Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1.
C nvrinht 0 2016 A-1 Rnnf T.,ecec- RenrMuntinn of thN dnntment. in anv fern. is nmhihited wrihoul the written nerrniccinn of A-1 RnnfTn-a%.
Job
CHHS3B
Truss
A10
I russ I ype wry I Illy
HIPS 1 1
UL/UU/LUGI
2635
m
`l
a =4)
iq
s-Ti s•
I - 9'11-11/16"
12 = 6X8
4 F,� D
23'4" -1- 9'11-11/16"-�
=3X4 =H0308 1111.5X4 =6X8
E F G H
4X4
6)C
(a)
(a)
(a)
=4X6 C
6(4X�
�(C6) 13
I-3J
K
Q PO N M L
1111.5X3 =H0308=4X4=4X8=HO308 1111.5X3
11j1'I/16AT41'4"E REQ. SEAT PLAT}�F"Q.
6 T/)6" 43'3-3/8" 6-116„
r
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 40.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 4.43 ft
Loc. from endwall: not in 6.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x6 SP 2400f-2.OE; T2,T3 2x4 SP M-30;
Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:;
B2 2x4 SP M-30;
Webs: 2x4 SP #3;
Lt Slider: 2x4 SP #2; block length = 1.750'
Rt Slider: 2x4 SP #2; block length = 1.750'
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 9.97 33.31
BC 57 0.00 43.28
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Deft/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.429 G 999 36
VERT(CL): 0.863 G 566 24
HORZ(LL): 0.099 1 - -
HORZ(TL): 0.201 1 - -
Creep Factor: 2.0
Max TC CSI: 0.779
Max BC CSI: 0.949
Max Web CSI: 0.769
Wgt: 215.6 Ibs
VIEW Ven 20.01.01A.0724.12
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 1788 /- /- /1003 /934 /101
J 1788 /- /- /1003 /934 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.5
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - C 967 -1287 F - G 4550 -4676
C - D 3308 -3574 G - H 4552 -4677
D - E 4518 -4648 H -1 3305 -3573
E - F 4550 - 4676 1- K 962 -1282
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 1315 -995 O - N 4685 -4286
B - Q 3284 -2927 N - M 3286 -2916
Q - P 3288 -2921 M - L 3286 -2916
P - O 3286 -2921 L - J 3282 -2922
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B - C
2690 - 2529
N - H
1533 -1620
D- Q
290 0
G- N
691 -457
D- O
1504 -1581
L- H
294 0
O - E
719 -463
I - J
2693 -2533
E-N
82 -58
**WARNING** ' Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be.valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the.Owner, the Owners authorized agent or the Building Designer, in.the context of the IRC, the IBC, local building rode and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling; storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrinht A 2016 A-1 Rnnf T.-- Renrndnntinn of thin doninnent. in anv form. is nmhihitnd withnut the written nermincion of A-1 Rnnf TnissAn.
CHHS3B
11-
yN-
A11 HIPS
..try I wry I uuvatcva r
2629
6-1116'
=4X
�-- 7'11-11/16" 274" 7'11-11/16" --{
4 p =6X10 =3X4 1111.5X4=4X6 =3X4 =6X10
D E F G H I
3X6(C6)( 4X4
6(C6) B
(a)
(a)
=4X6(C
J=3X6(C )
K�4X4
A
L
S R Q P O N M
III1.5X3 =4X6=H0308 =3X8 =H0308=4X6 III1.5X3
tS . fi,PLATE REQ. LATE SEAT PA5Q.
41'4"
6-T/16„ r 6-T/]6„
43'3-3/8"
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 4.43 ft
Loc. from endwall: not in 6.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x6 SP 2400f-2.OE; T2,T3 2x4 SP M-30;
Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:;
B2 2x4 SP M-30;
Webs: 2x4 SP #3;
Lt Slider: 2x4 SP #2; block length = 1.750'
Rt Slider: 2x4 SP #2; block length = 1.750'
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.97 35.31
BC 53 0.00 43.28
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Deft/CSI Criteria
PP Deflection in loc L/defi L/#
VERT(LL): 0.606 F 806 360
VERT(CL): 1.222 F 400 244
HORZ(LL): 0.098 M - -
HORZ(TL): 0.199 M -
Creep Factor: 2.0
Max TC CSI: 0.719
Max BC CSI: 0.956
Max Web CSI: 0.817
Wgt: 211.4 Ibs
VIEW Ver. 20.01.01A.0724.12
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 1788 /- /- /1001 /935 /83
K 1788 /- /- /1001 /935 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
K Brg Width = 8.0 Min Req = 1.5
Bearings B & K are a rigid surface.
Bearings B & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - C 1066 -1275 G - H 5775 - 5905
C - D 3398 - 3575 H -1 5159 - 5255
D - E 5159 - 5255 I - J 3398 - 3575
E - F 5775 - 5905 J - L 1066 -1275
F - G 5775 - 5905
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B
1308 -1090
P - O
5322 - 5006
B - S
3283 - 3020
O - N
5322 - 5006
S - R
3286 - 3013
N - M
3286 - 3011
R - Q
5322 - 5008
M - K
3283 - 3019
Q - P
5322 - 5008
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
B - C
2640 -2543
P - H
643 - 652
D-S
213 0
H-N
894 -679
D - R
2144 -2177
N - I
2144 -2177
R - E
894 - 679
M -1
213 0
E - P
643 -652
J - K
2640 -2543
F - P
561 - 377
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As.a Truss Design Engineering (i.e. Specialty Engineer),the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Ostam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI.1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvriaht nc 2016 A-1 RnofTntccea- Renmdnrlinn of thN domiment. in anv form. is nmhihired without the writtnn nerrnl clnn of A-1 RnnfTni nc.
dOD truss I runs i ype W y cry ucruarcuc
CHHS3B Al2 HIPS 1 2 2632
7.
207# 122# 122# 122# 122# 122# 122# 122# 207#
+ 122# + 122#, + 122#+ + 122f( + 122#+ + 122#+ + 122#+ + 122#+
i-- 6'6" i31'4" -i_ 6'6"
12
4 =6X10 =4X4 1111.5X3=HO510 =3X4 mH0308=4X4 =6X10
C D E F G H I J
TT �3X6(C6)rsts/ts=4XA6(C6
1j 3-12R•
T
III1.5X3
J R l.t
E3X10 szH0510 =3X10
=4X4 =H0510 sa3X10
III1.5X3
4X6(C6)
L
SEA'( PLATE REQ. SEAT PLA,%fZEQ.
IL 6 41'4" � {
6'6-3/8"9'09'=-3/8i 2, I 2, I 2, I 2, I 2, I Z +1//77-1/ 2,-�- 2,-t 2, -I 2,-�- 2, I 2, 0-3/8 i
191# 82# 82## 82## 82# 82## 82## 82# 82# 82## 82# 82#82#82# 82## 82'#J`1911'#�
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 40.00
Mean Height: 25.00 ft
NCBCLL: 0.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 5.0 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 4.43 ft
Loc. from endwall: not in 6.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30; T2,T3 2x4 SP 2400f-2.0E +
SP M-31;
Bot chord: 2x6 SP 2400f-2.OE;
Webs: 2x4 SP #3; W2 2x4 SP #2;
Lt Slider: 2x4 SP #3; block length = 1.750'
Rt Slider: 2x4 SP #3; block length = 1.750'
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @12.00" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
(1)1/2" bolts may be used for
(2) 0.131"x3", min. nails on
The Bottom Chord Only.
Special Loads
-(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 61 plf at 0.00 to 61 plf at 6.50
TC: From 31 plf at 6.50 to 31 plf at 37.83
TC: From 61 plf at 37.83 to 61 plf at 44.33
BC: From 20 plf at 0.00 to 20 plf at 6.53
BC: From 10 plf at 6.53 to 10 plf at 37.80
BC: From 20 plf at 37.80 to 20 plf at 44.33
TC: 207 lb Conc. Load at 6.53,37.80
TC: 122 lb Conc. Load at 8.56,10.56,12.56,14.56
16.56,18.56,20.56,22.17,23.77,25.77,27.77,29.77
31.77,33.77,35.77
BC: 191 lb Conc. Load at 6.53,37.80
BC: 82 lb Conc. Load at 8.56,10.56,12.56,14.56
16.56,18.56,20.56,22.17,23.77,25.77,27.77,29.77
31.77,33.77,35.77
Code / Misc Criteria
Defi/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl U#
Gravity Non -Gravity
TPI Still: 2014
VERT(LL): -0.967 E 505 360
Loc R+ / R- / Rh / Rw / U / RL
Rep Factors Used: No
VERT(CL): 1.586 E 308 244
U 3092 /- /- /- /2083 !-
FT/RT:10(0)/10(10)
HORZ(LL): -0.119 C - -
V 3092 !- /- /- 12083 /-
Plate Type(s):
HORZ(TL): 0.196 C - -
Wind reactions based on MWFRS
WAVE, HS
Creep Factor: 2.0
U Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.929
V Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.989
Bearings U & V are a rigid surface.
Bearings U & V require a seat plate.
Max Web CSI: 0.707
Maximum Top Chord Forces Per Ply (Ibs)
Wgt:467.6lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 20.01.01A.0724.12
A - B 1308 -1942 G - H 4832 -7083
Purlins
B - C 2105 -3047 H -1 4832 -7083
C - D
-7076 I - J
-3054
In lieu of structural panels or rigid ceiling use purlins
4832 2110
D - E 4832 -7076 J - K 2110 -3054
to laterally brace chords as follows:
E - F 4832 -7076 K - L 1319 -1956
Chord Spacing(in oc)
Start(ft) End(ft)
TC 24
6 50 37 83
F - G 4832 - 7076
BC 76 0.00 44.33
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
U - T
2847 -1966
P - O
5855 -4020
A - U
1881 -1260
O - N
5855 -4020
T - S
2834 -1949
N - M
2841 -1954
S - R
5870 -4029
M - K
2854 -1971
R - Q
5870 -4029
K - L
1895 -1271
Q - P
7121 -4873
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - T
265 -210
G - P
305
-276
C - S
3107 -2107
P -1
1308
- 862
S - D
634 -760
I - N
642
-774
D - Q
1281 - 850
N - J
3081
- 2090
E - Q
302 -272
M - J
262
- 204
Q - G
44 -50
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. Asa Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents, an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context ofthe.IRC, the IBC, local building code and TPIA.. The approval of the TDD and any field .. .... # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notessetout in the TDD and the practices and 4451 St. Lurie Blvd, Suite 201..
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C-nitht 0 2016 A-1 Rnnf Tn,--- Rrnmdadinn of this dnrarment, in Rnv form. in nmhihitnd without the written nwmissinn of A-1 Ronf Tri-s.
CHHS3B
B01 SPEC
2651
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BOLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x8 SP 2400f-1.8E;
T2 2x4 SP 2400f-2.0E + SP M-31;
Bot chord: 2x4 :SP 2400E-2.0E + SP M-31:;
132 2x6 SP 2400f-2.0E;
Webs: 2x4 SP #3; W4 2x8 SP 2400f-1.8E;
W7 2x6 SP #2;
Lt Slider. 2x4 SP #3; block length = 1.750'
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 72 0.00 5.99
BC 67 9.53 15.10
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
1- 67-1/8' 1 24-10--1--62-7/8•
MAW
I
it
AA.?UTE REQ.
. 14'9'
-67-1/8' T4.1re•6'2af8'
10'4.314' 4'
160# t5
Code / Misc Criteria
DeflICSI Criteria
♦ Maximum Reactions (Ibs)
Code:FBC 7th Ed. 2020 Res.
PP Deflection in loc Udefl U#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.276 F 614 360
Loc R+ / R- / Rh / Rw / U / RL
B 787 /_ /_ /403 /272 /278
Rep Factors Used: Varies by Ld C
$4_-RT(CL): 0.706 F 240 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.120 M - -
K 852 A A /294 /297 /-
Plate Type(s):
HORZ(TL): 0.307 M - -
Wind reactions based on MWFRS
WAVE, HS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.669
K Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.199
Bearings B & K are a rigid surface.
Bearing B requires a seat plate.
Max Web CSI: 0.349
Maximum Top Chord Forces Per Ply (Ibs)
Wgt: 117.6lbs
Chords Tens.Comp. ' Chords Tens. Comp.
VIEW Ver. 20.01.01A.0724.12
B - C 135 -509 E - F 159 -586
F - G 4814 - 5061 G - H 710 -1165
A-B 15 0 H-1 716 -1147
C - D 487 -1026 I - J 64 - 98
D - E 526 -1021
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - O 920 - 827 G - M 1389 -1063
O - N 825 - 700 M - L 1391 -1073
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B-C
984-1104
M-1
319 -190
D - O
233 -136
I - L
1173 -1503
O - E
129 -158
L - K
666 - 851
E - N
1158 -1356
L - J
155 - 72
N - F
1211 -1004
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (Le. Specialty Engineer), the sea[ on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitabilityand use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field. - # 88906
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Conwiaht 0 2016 A-1 Roof Tnu-- Renroduntinn of thic do -P.M. in anv fnnn. In nrohihited vAhnut tha written nanniaainn of A-1 Ronf T-ac.
JOD 1 russ 1 russ I We arty cry uuwrcuc r
CHHS3B B02 HIPM 1 1 2592
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
14'6"
SEAT PLATE REQ.
1'6" j 14'8"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Lt Slider: 2x6 SP #2; block length = 2.750'
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 14.50 16.17
BC 75 0.00 16.17
Apply purins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
c5X6 III1.5X3
D E
SEAT PLATE REQ.
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc Udefl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.058 C 999 360
Loc R+ / R- / Rh / Rw / U / RL
H 737 /- /- /454 /262 /253
Rep Factors Used: Yes
VERT(CL): 0.118 C 999 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.027 B - -
1 578 /- /- /313 /272 /-
Plate Type(s):
HORZ(TL): 0.055 B - -
Wind reactions based on MWFRS
WAVE
Creep Factor: 2.0
H Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.807
1 Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.667
Bearings H & I are a rigid surface.
Bearings H & I require a seat plate.
Max Web CSI: 0.937
Maximum Top Chord Forces Per Ply (Ibs)
Wgt:88.9lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver. 20.01.01A.0724.12
A - B 85 -489 C - D 783 -962
B-C 622 -955 D-E 0 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
H - G 868 - 882 G - F 155 - 211
A-H 519 -53
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp. Webs Tens. Comp.
H - B
1059 -1025 D - F 652 -480
C - G
566 -361 E - F 117 -50
G - D
848 -776
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineeri
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval .of the TDD and any field .
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
rnnvdnht Q 201a A-1 Roof Tnisses - Reoroduntion of this donrrment. in anv form. is nrohibited Without the when nermissino of A-1 Rnaf Tmcses.
Rama Pranali I(ristam, P.E.
#.88906-
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
goo t runs truss type sty riy u.<fuaicu d i
CHHS3B 603 HIPM 1 1
2593
3-1sTt6•
12'6" 3'8" —�
=5X6 1111.5X4
D E
SEAT PLATE REC. SEAT PLATE REQ.
1'6" 14'8"
16'2"
Loading Criteria (psf) Wind Criteria
Code I Misc Criteria
Deft/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc Udefl L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.054 C
999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.108 C
999 240 H 737 !- /- /454 /274 /218
BCDL: 10.00 Risk Category:11
FT/RT:10(0)110(10)
HORZ(LL):-0.024 B
- - 1 578 /- /- /307 /288 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.050 B
- - Wind reactions based on MWFRS
Des Ld: 40.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 20.
H Br Width = 8.0 Min Re 1.5
9 q =
NCBCLL: 10.00 TCDL: 5.0 sf
P
Max TC CSI: 0.659
I Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25 BCDL: 5.0 sf
P
"
Max BC CSI: 0.826
Bearings H & I are a rigid surface.
Spacing: 24.0 MWFRS Parallel Dist: h/2 to h
Bearings H & I require a seat plate.
C&C Dist a: 3.00 ft
Max Web CSI: 0.537
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 9.00
Wgt: 81.9 Ibs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 20.01.01A.0724.12
A - B 115 -412 C - D 883 -985
Lumber
B- C 759 -988 D- E 0 0
Top chord: 2x4 SP #2;
-
Bot chord: 2x4 SP #2;
Maximum Bot Chord Forces Per Ply (Ibs)
Webs: 2x4 SP 43;
Chords Tens.Comp. Chords Tens. Comp.
Lt Slider: 2x6 SP #2; block length = 2.750'
H - G 898 -964 G - F 336 -490
Purlins
A - H 443 -79
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Maximum Web Forces Per Ply (Ibs)
Chord Spacing(in oc) Start(ft) End(ft)
Webs Tens.Comp. Webs Tens. Comp.
TIC 24 12.50 16.17
BC 75 0.00 16.17
H - B 1076 -1076 D - F 745 - 510
Apply purins to any chords above or below fillers
C - G 451 -252 E - F 257 -112
at 24" OC unless shown otherwise above.
G - D 672 -541
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field - - - # 88906 -
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Convrinht 0 2016 A•1 Rnof T.-- Ranmd,,dion of thisi dounrient. in anv form. le nmhihited without the written nerniaalon of A.1 Roof Tnrseea.
Job Truss Iruss type uty Fly urruafZUZ9
CHHS3B I B04 HIPM 1 1
2594
3.1T6'
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
SEAT PLATE REQ.
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Lt Slider: 2x6 SP #2; block length = 2.750'
Purlins
In lieu of structural panels or rigid ceiling use purins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.50 16.17
BC 75 0.00 16.17
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
10'6" 15'8" �{
14'8"
16'2"
=5X6 1113X4(R)
D E
Code / Misc Criteria
Defl/CSI Criteria
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
TPI Std: 2014
VERT(LL): -0.040 C 999 361
Rep Factors Used: Yes
VERT(CL): 0.064 C 999 241
FT/RT:10(0)/10(10)
HORZ(LL): -0.008 F - -
Plate Type(s):
HORZ(TL): 0.014 B -
WAVE
Creep Factor: 2.0
Max TC CSI: 0.759
Max BC CSI: 0.710
Max Web CSI: 0.729
Wgt: 86.1 Ibs
VIEW Ver. 20.01.01A.0724.12
11
ro
17
01
co
1
SEAT PLATE REQ.
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
H 737 /- /- /452 1434 /258
1 578 /- !- /302 1414 !-
Wind reactions based on MWFRS
H Brg Width = 8.0 Min Req = 1.5
1 Brg Width = 8,0 Min Req = 1.5
Bearings H & I are a rigid surface.
Bearings H & I require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 85 - 519 C - D 773 - 695
B-C 951 -886 D-E 819 -617
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
H-G 804 -1074 G-F 10 -20
A - H 538 - 59
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp. Webs
Tens. Comp.
H - B
1352 - 983 G - E
721 - 949
C - G
294 -192 E - F
859 - 537
D - G
525 -177
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
- connector plates shall be used for the TDD to be valid. Asa Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Mstam, P.E.
...responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the.TDD and any field # 88906 -
use of the Truss. including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C' nvri"ht (o 2016 A-1 Rnnf Tn,- -c — Rnnrndu Jinn of this domiment. in rtnu form. N nmhihited withmd the written nnrmi"sine of A-1 Rnnf Tniscen.
jou
CHHS3B
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
I Iij.1 II- IyFIG
B05 HIPM
�tT.
Vly rly VGiVJIGVGI
1 1
354# 1811 181+ 181
8'6' 7'8'
1112X4
SEAT PLATE REQ. 1'6' 14'6°
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 :SP 2400f-2.OE + SP M-31:;
T2 2x4 SP #2;
Bot chord: 2x4 :SP 2400f-2.0E + SP M-31:;
B2 2x4 SP M-30;
Webs: 2x4 SP #3;
Lt Slider: 2x6 SP #2; block length = 2.750'
Special Loads
--(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 61 plf at 0.00 to 61 plf at 8.50
TC: From 31 plf at 8.50 to 31 plf at 16.17
BC: From 20 plf at 0.00 to 20 pif at 8.65
BC: From 10 pif at 8.65 to 10 plf at 16.17
TC: 354 lb Conc. Load at 8.53
TC: 181 lb Conc. Load at 10.56,12.56,14.56
BC: 422 lb Conc. Load at 8.53
BC: 122 lb Conc. Load at 10.56,12.56,14.56
Purlins
In lieu of structural panels or rigid ceiling use purins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 8.50 16.17
BC 69 0.00 16.17
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
16'2'
8'6-3/8' 70-3/8" 2 --� 2
422# 122# 122# 1
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
DeflICSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL): -0.117 C 999 36
%q-=RT(CL): 0.200 H 107 24
HORZ(LL): 0.064 B - -
HORZ(TL): 0.132 B - -
Creep Factor: 2.0
Max TC CSI: 0.704
Max BC CSI: 0.976
Max Web CSI: 0.755
Wgt: 83.3 Ibs
VIEW Ver. 20.01.01A.0724.12
T
i"
1
SEAT PLATE REQ.
2609
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
1 1294 /- /- /- /925 /-
J 1394 /- /- /- /1005 /-
Wind reactions based on MWFRS
I Brg Width = 8.0 Min Req = 1.5
J Brg Width = 8.0 Min Req = 1.6
Bearings I & J are a rigid surface.
Bearings I & J require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 192 - 586 C - D 1161 -1597
B - C 1590 -2143 D - E 1161 -1597
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
I - H 1958 -1440 H - G 1981 -1445
A -I 582 -182 G-F 10 -7
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
I - B
1525 -1768
D - G
626 - 574
C - H
450 - 99
G - E
1982 -1441
C - G
354 -480
E - F
1011 -1318
-WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TOO) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
.connector plates shall be used for.the TDD. to be valid. As a Truss Design Engineering (i.e. Specialty.Engineer), the seal on any TOO represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TOO only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, In the context of the IRC, the IBC, local building code and TPI-1. The approval of the TOO and any field - 488906
use of the Truss,'including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOO and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
rtnnvrimht 99 2016 A-1 Rnef TnI. w� - Rnnmdu dinn of this Annlment. in anv fnnn. Is nmhihhad vrithnut tha writtan nannMinn of A-1 Ronf Tnii-,
Job Truss Truss Type city Illy ulrua/ZUZI 2595
CHHS3B I B06 HIPM 1 1
2
& Uj-
SEAT PLATE REQ.
�- 1'6"
14'4"
20'8"
T1 On
-6X6 1113X6(R)
F G
i
SEAT PLATE REQ.
2'6" 1
227
J
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defi/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc Udefl L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): -0.102 1 209 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.170 D 999 240
J 1153 /- P 1745 /563 /298
BCDL: 10.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.048 C - -
K 815 /- /- /423 /444 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.067 C - -
Wind reactions based on MWFRS
Des Ld: 40.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 20.
J Br Width = 8.0 Min Re 1.5
9 q =
NCBCLL: 10.00 TCDL: 5.0 sf
p
Max TC CSI: 0.720
K Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25 BCDL: 5.0 psf
"
Max BC CSI: 0.552
Bearings J & K are a rigid surface.
Spacing: 24.0 MWFRS Parallel Dist: h/2 to h
Bearings J & K require a seat plate.
C&C Dist a: 3.00 ft
Max Web CSI: 0.769
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from l: not in 9.00
Wgt: 128.8 Ibs
Chords Tens.Comp. Chords Tens. Comp.
0.18
pi: 0.1
GCpi:
Wind Duration: 1.60
VIEW Ver: 20.01.01A.0724.12
B - C 85 -657 D - E 871 -1005
Lumber
A - B 52 0 E - F 889 - 980
C - D 1205 -1445 F - G 948 - 895
Top chord: 2x4 SP M-30; T1 2x4 SP 2400f-2.OE +
SP M-31;
Bot chord: 2x6 SP 2400f-2.OE; B2 2x6 SP #2;
Maximum Bot Chord Forces Per Ply (Ibs)
Webs: 2x4 SP #3;
Chords Tens.Comp. Chords Tens. Comp.
Lt Slider. 2x4 SP #3; block length = 1.750'
J-B 761 -99 I-H 0 0
Bracing
J -1 1324 -1371
(a) Continuous lateral restraint equally spaced on
member.
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
Purlins
In lieu of structural panels or rigid ceiling use purlins
B - C 1557 -1171 I - G 1051 -1112
D - I 428 -446 G - H 981 -747
to laterally brace chords as follows:
F - I 649 -249
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 14.33 22.17
BC 120 0.00 22.17
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT"forn. '
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engirleerin ..
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owners authorized agent or the. Building Designer, In the context.of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and " - - 4451 St Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
CnnvrinhtQ 2016 A-1 RnnfTntsses-Renrndnntinn of this dom-nt. in anv fnrm. In nmhihited withmn the written nxnni, inn of A-1 RnnfTnrecxc.
doo r Fuss I Fuss type Wry rty uuuarcuc t
CHHS3B B07 HIPM 1 1 2596
3-1=51W
12'6" 9'8"
=5X6 =3X4 1111.5X4
D E F
SEAT PLATE REQ.
�_ 1'6" 1 20W
L
SEAT PLATE REQ.
22'2" —1
T
io
L6
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
DeflICSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc Udefl U# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.084 C
999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.168 C
999 240 K 978 /- /- 1581 /374 /218
BCDL: 10.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.030 B
- - L 823 /- /- /430 /479 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.060 B
- - Wind reactions based on MWFRS
Des Ld: 40.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 20.
K Br Width = 8.0 Min Re 1.5
9 q =
NCBCLL: 10.00 TCDL: 5.0 sf
p
Max TC CSI: 0.810
L Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25 BCDL: 5.0 psf
Max BC CSI: 0.966
Bearings K & L are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
Bearings K & L require a seat plate.
C&C Dist a: 3.00 ft
Max Web CSI: 0.734
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 9.00
Wgt: 114.1 Ibs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver: 20.01.01A.0724.12
A- B 180 -282 D - E 1185 -1064
Lumber
B- C 1290 -1430 E- F 0 0
C-D 1162 -1168
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2; B2 2x4 SP M-30;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Lt Slider: 2x6 SP #2; block length = 2.750'
Chords Tens.Comp. Chords Tens. Comp.
Purlins
K - J 1303 -1412 I - H 1303 -1417
- K 279 -159 H - G 720 -976
In lieu of structural panels or rigid ceiling use purlins
J 1417
- I 1303 -417
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 12.50 22.17
Maximum Web Forces Per Ply (Ibs)
BC 87 0.00 22.17
Webs Tens.Comp. Webs Tens. Comp.
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
K - B 1408 -1342 H - E 473 - 279
J - C 131 -4 E - G 1294 -954
Wind
C - H 242 -257 F - G 236 -120
Wind loads based on MWFRS with additional C&C
D - H 213 -5
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
"WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seat on any TDD represents an acceptance.of the professional engineering
responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI4..The approval of the TDD and any field 488906
use of the Truss, Including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TDD and the practices and '4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
C nvdaht Q 2n1fi A-1 Ronf Tnt. ca-c — RenmdurAion of Ihlc dam anent. in anv farm. is nrnhihited without thn written narmir,.cinn of A-1 Roof Tri cnc.
Job Truss Truss Type Qty Ply 0210912021
CHHS36 I B08 HIPM 1 11 I 2597
M
3.1aTa-
10'6" — -1 11'8"
III1.5X4
;L
SEAT PLATE REQ. SEAT PLATE REQ.
W. 120'8"
22'2"
11
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): -0.079 C 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.138 J 999 240
K 978 /- /- /578 /603 /258
BCDL: 10.00
Risk Category:11
FT/RT:10(0)/10(10)
HORZ(LL):-0.018 G - -
L 823 /- /- 1426 /569 /-
Des Ld: 40.00
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.030 G -
Wind reactions based on MWFRS
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
K Brg Width = 8.0 Min Req = 1.5
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.849
L Brg Width = 8.0 Min Req = 1.5
Load Duration: 1.25
"
BCDL: 5.0 sf
p
Max BC CSI: 0.955
Bearings K & L are a rigid surface.
Spacing: 24.0
MWFRS Parallel Dist: 0 to h/2
Bearings K & L require a seat plate.
C&C Dist a: 3.00 ft
Max Web CSI: 0.705
Loc. from endwall: not in 9.00
Maximum Top Chord Forces Per Ply (Ibs)
Wgt: 118.3 Ibs
Chords Tens.Comp. Chords Tens. Comp.
GCpi: 0.18
Wind Duration: 1.60
VIEW Ver. 20.01.01A.0724.12
A - B 66 -340 D - E 1357 -1040
Lumber
B - C 1477 -1395 E - F 1357 -1040
C - D 1442 -1313
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Lt Slider: 2x6 SP #2; block length = 2.750'
Chords Tens.Comp. Chords Tens. Comp.
Bracing
K - J 1262 -1520 1- H 1214 -1457
(a) Continuous lateral restraint equally spaced on
A - K 343 -64 H - G 11 -15
member.
J -1 1214 -1457
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 10.50 22.17
BC 67 0.00 22.17
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
K - B 1733 -1405 E - H 821 - 395
C - J 209 -206 H - F 1203 -1569
D- J 265 0 F- G 1106 - 772
D - H 148 -204
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
-
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless othetvdse stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering O.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and.any field
.,
... — -.. # 88906 — ..
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor._ All notes set out in the TDD and the practices and
4451 St Lude Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
C nvrinht Q 2016 A-1 Ronf Tni sm — Rnnrndurlinn of this dnmrment. in anv fnnn. is nmhihited wdhnuf the vrtMten oermic im of A-1 Rmf Tntcses.
JUU
CHHS3B
I l ubb I l ub 11 yNC
B09 HIPM
illy r ly U41UU14U4 1
1 1
2648
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
3-,RV
174181#+ 181+ 181#+ 181+
13'8'
a5X8 m4X4
181#
181#+ + 18130 3!1fi°
SEAT PLATE REQ. SEAT PLATE REQ.
1'6' 20'8"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 It
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 :SP 2400f-2.OE + SP M-31:;
Bot chord: 2x6 SP 2400f-2.0E;
Webs: 2x4 SP #3; W3 2x4 SP #2;
Lt Slider: 2x4 SP #3; block length = 1.750'
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Special Loads
(Lumber Dur.Fac.=1.25 / Plate Dur.Fac: 1.25)
TC: From 61 pIf at 0.00 to
61 pIf at 8.50
TC: From 31 plf at 8.50 to
31 pIf at 22.17
BC: From 20 plf at 0.00 to
20 plf at 8.50
BC: From 10 plf at 8.50 to
10 plf at 22.17
TC: 174 lb Conc. Load at 8.50
TC: 181 lb Conc. Load at 9.15,11.15,13.15,15.15
17.15,19.15,21.15
BC: 300 lb Conc. Load at 8.50
BC: 122 lb Conc. Load at 9.15,11.15,13.15,15.15
17.15,19.15,21.15
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 8.50 22.17
BC 68 0.00 22.17
Apply purins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
22'2'
7 1311 ,�yy"
30'a 2 2 12 2 12 2 1 2 1� 2 122# 2
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE, HS
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.226 C 999 36,
keERT(CL): 0.345 1 709 240
HORZ(LL): 0.060 B - -
HORZ(TL): 0.103 B - -
Creep Factor. 2.0
Max TC CSI: 0.887
Max BC CSI: 0.990
Max Web CSI: 0.875
Wgt: 119.0 Ibs
VIEW Ver. 20.01.01A.0724.12
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
J 1838 /- A /- /1316 /-
K 1998 /- A /- /1420 /-
Wind reactions based on MWFRS
J Brg Width = 8.0 Min Req = 1.5
K Brg Width = 8.0 Min Req = 1.7
Bearings J & K are a rigid surface.
Bearings J & K require a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 1318 -2091 C - D 2593 -3623
B - C 2577 - 3528 D - E 2593 - 3623
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
J -1 3286 -2389 H - G 3301 -2385
A - J 2023 -1260 G - F 33 - 30
1- H 3301 - 2385
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp. Webs Tens. Comp.
C -1
292 0 G - E 3877 - 2768
C - G
409 -224 E - F 1417 -1794
D - G
1104 - 980
-WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal an any TDD represents an acceptance of the professional.engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the-TDD and any -field . # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TOO and the practices and 4451 St. Luce Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C' nvd.ht 0 2016 A-1 Rnnf Tm-- Renmdnrtinn of thta domrment. in anv form. is nmhlhaed Ahnut tha written nnrmircinn of A-1 Rnmf Tnresec.
JOO
CHHS3B
I russ I russ I ype ury Illy
1 .IACK 8 1
UL/UWLUG 1
2598
121
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
12
4
B
2X4(A1) A T
_T_ 7-15/16"
3-15-/�9 6"
C
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 8 0.36 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
"... BEARING ANALOG MODIFIED! •""
I®-1 , --siI
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defi/CSI Criteria
PP Deflection in loc Udefl L/#
VERT(LL):0.000 - - 360
VERT(CL): 0.000 - - 240
HORZ(LL):0.000 - - -
HORZ(TL):0.000 - - -
Creep Factor: 2.0
Max TC CSI: 0.021
Max BC CSI: 0.007
Max Web CSI: 0.000
Wgt: 4.2 Ibs
VIEW Ver: 20.01.01A.0724.12
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 35 /- /46 /25 /32 /26
C 21 /- 146 /11 /6 /39
Wind reactions based on MWFRS
B Brg Width = 1.5
C Brg Width = 1.5
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 55 -131
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A - C 156 -49
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedri
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Mstam, P.E.
responsibility of the Owner,, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code.and TPI-1. The approval of the TDDand any field. # 88906
use of the Truss, including handling, storage, Installation and bracing shall bathe responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnovdaht Q 2016 A-1 Rmmf Tntzaaa — RrnmdunAinn of thk do arment. in anv fnnn, is nmhihNad without tha vmttan namri-jan of A-1 Ronf T—
Job
CHHS3B
I russ I russ I ype city Fly
CJ3 JACK 1 8 1 1
U2/U9/2U21
2599
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP 42;
Webs: 2x6 SP #2;
12
4 C
III 1.5X B
X4(A1 HB 11-1/4"
3-15 16°
F E D
1113X6(")
SEAT PLATE REQ.
�— 1'6" ---�
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Plating Notes
(") 1 plate(s) require special positioning. Refer to
scaled plate plot details for special positioning
requirements.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 36 0.00 3.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
2'0-3/4" +11
1 3'
so
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc Udefl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.019 E 999 360
Loc R+ ! R- / Rh / Rw / U / RL
F 389 /- /- /321 /208 /73
Rep Factors Used: Yes
VERT(CL): 0.037 E 661 240
FT/RT:10(0)/10(10)
HORZ(LL); -0.006 C - -
D - /-79 !- /59 /85 /-
Plate Type(s):
HORZ(TL): 0.013 C - -
C - /-85 /- /41 !75 /-
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.279
F Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.191
D Brg Width = 1.5 Min Req = -
Max Web CSI: 0.104
C Brg Width = 1.5 Min Req = -
Bearing F is a rigid surface.
Wgt: 11.9 Ibs
Bearing F requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver. 20.01.01A.0724.12
Chords Tens.Comp. Chords Tens. Comp.
A - B 75 -249 B - C 28 -40
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- E 288 -43 E- D 0 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
B - E 674 -237
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ('SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a.Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval.of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvriaht 02016 A-1 Roof To— — Ranmtlnrlinn of this doormat. in anv form, is nmhibited withmit thn wriftnn nannission of A-1 Roof Tnrxcnc.
Job
CHHS3B
Truss
CJ5
Truss Type Qty Ply U2/US12U21
JACK 1 8 1 1
2600
r
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
3-1516"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP 42;
Bot chord: 2x4 SP #2;
Lt Slider: 2x6 SP #2; block length = 2.750'
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 60 0.00 5.00
Apply puriins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
12 C
A
l�
,r
LO
r
SEAT PLATE REQ.
1 r6rf
�5'�
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code:FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): -0.040 B 962 360
Loc R+ / R- / Rh / Rw / U / RL
E 316 /- /- /233 /148 /122
Rep Factors Used: Yes
VERT(CL): 0.032 B 999 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.026 B - -
D 52 /- A /28 /- /-
Plate Type(s):
HORZ(TL): 0.029 B - -
C 76 A A /25 /100 /-
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TIC CSI: 0.576
E Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.235
D Brg Width = 1.5 Min Req = -
Max Web CSI: 0.190
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Wgt: 21.7 Ibs
Bearing E requires a seat plate.
Maximum Top Chord_ Forces Per Ply (Ibs)
VIEW Ver: 20.01.01A.0724.12
Chords Tens.Comp. Chords Tens. Comp.
A-B 381 -936 B-C 24 -90
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
E- D 0 0 A- E 993 - 335
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
E - B 908 -411
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used forthe TDD to be valid, As a Truss Design Engineering (Le, Specialty Engineer), the seal on any TDD,represents an acceptance of the professional engineerin _
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading.conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the.Ownees authorized agent or.the Building. Designer, in the context of the IRC, the IBC, local building code.and TPI-1.. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and - - 4451 St. Lurie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
Cnnvrinht 0 2016 A-1 Rnnf Tni,-- Ranrndurtinn of this dmimant. in anv form. is nmhihil"d vrithad tho wr ttnn nrmrissinn of A-1 Rnnf Tni—s.
Job
CHHS3B
Truss Truss Type
CJ7 JACK
Qty Ply 02/09/2021
4 1
2601
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
SEAT PLATE REQ.
�- 1'6"----
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Lt Slider: 2x6 SP #2; block length = 2.750'
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
C
to
CN
1
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): -0.121 B 516 360
Loc R+ / R- / Rh / Rw / U / RL
E 381 /- /- /264 /188 /172
Rep Factors Used: Yes
VERT(CL): 0.115 B 545 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.084 B - -
D 92 /- /- /50 /4 /-
Plate Type(s):
HORZ(TL): 0.094 B - -
C 137 P P /52 K63 P
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.850
E Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.498
D Brg Width = 1.5 Min Req = -
Max Web CSI: 0.255
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Wgt: 27.3 Ibs
Bearing E.requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver. 20.01.01A.0724.12
Chords Tens.Comp. Chords Tens. Comp.
A-B 475-1214 B-C 43 -136
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
E- D 0 0 A- E 1257 -429
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
E - B 1156 - 529
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid.. As a Truss Design Engineering (t.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in vrtiting by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1.
Cnnvriaht 02nl6 A-1 RonfTnracr_c— RenrMllrlian of this dnannent. in anv fnrm. is nmhihited without the written nermission of A-1 Rnof Tmcses.
Job
CHHS3B
Truss Truss Type Qty Ply
HJ5 HIP_ 2 1
U2/U9/ZU21
2606
Y
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BOLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Lt Wedge: 2x6 SP #2;
Special Loads
3-1T6-
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
--(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 2 plf at 0.00 to 2 plf at 9.13
BC: From 2 plf at 0.00 to 2 plf at 9.13
TC: 70 lb Conc. Load at 1.46
TC: -38 lb Conc. Load at 4.29
TC: 152 lb Conc. Load at 7.12
BC: 42 lb Conc. Load at 1.46
BC: -75 lb Conc. Load at 4.29
BC: 104 lb Conc. Load at 7.12
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 9.13
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
70 i 152#
38#�
2'0-3/16" �{
12 B
SEAT PLATE REQ.
2'0-11/16"
9'1-9/16"
1'5-1/2" -t - 2'9-15/16" - 1 2'9-15/16- ---�
42# 75# 104#
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defi/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc Udefl L/#
Gravity Non -Gravity
VERT(LL): -0.062 C 999 360
Loc R+ / R- / Rh / Rw / U / RL
A 382 /- /- /- /371 /-
IVr:RT(CL): -0.064 C 999 240
HORZ(LL): -0.083 C - -
C 109 A /- /- /48 /-
HORZ(TL): 0.084 C - -
B 85 /- A /- /156 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.704
A Brg Width = 11.3 Min Req = 1.5
Max BC CSI: 0.626
C Brg Width = 1.5 Min Req = -
Max Web CSI: 0.000
B Brg Width = 1.5 Min Req = -
Bearing A is a rigid surface.
Wgt: 32.2 Ibs
Bearing A requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
VIEW Ver. 20.01.01A.0724.12
Chords Tens.Comp.
A - B 43 - 35
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 0 0
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design. Engineering (.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the.context of the IRC, the IBC, local building code and TPI-1.. The approval of.the.TOD and any field .. _. . 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lune Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon In writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPIA.
Cnnvriaht 0 2016 A-1 Rnnf T.-- Renrnduntion of this d-ment. in anv fnnn. in nmhihited without the written nenniacion of A-1 Ronf Tntsrxa.
°JUU
CHHS3B
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
I rubb Ilubb Iyt1C
HJ8 HIP_
70 i -38#+
SEAT PLATE REQ.
�- 2'0-11/16" 4{
%ALY I 1y UL,V.-1,LUL1
152#
+ 273
2'0-3/16" �{
D
11'11-1/2°
1-5-1/2' 2'9-15/16" 2 9 15/16" 2 9 15/16"
-75# � 184#
42# 104#
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP M-30;
Webs: 2x4 SP #3;
Lt Slider: 2x6 SP #2; block length = 3.889'
Special Loads
-(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 2 plf at 0.00 to 2 plf at 11.96
BC: From 2 plf at 0.00 to 2 plf at 11.96
TC: 70 lb Conc. Load at 1.46
TC: -38 lb Conc. Load at 4.29
TC: 152 lb Conc. Load at 7.12
TC: 273 lb Conc. Load at 9.94
BC: 42 lb Conc. Load at 1.46
BC: -75 lb Conc. Load at 4.29
BC: 104 lb Conc. Load at 7.12
BC: 184 lb Conc. Load at 9.94
Purlins
In lieu of structural panels or rigid ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 93 0.00 11.96
Apply puriins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Varies by Ld
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.048 C 999 361
kfERT(CL): 0.054 C 999 241
HORZ(LL): -0.010 B - -
HORZ(TL): 0.019 B - -
Creep Factor: 2.0
Max TC CSI: 0.970
Max BC CSI: 0.989
Max Web CSI: 0.311
Wgt: 53.2 Ibs
VIEW Ver. 20.01.01A.0724.12
T
C?
!6
2607
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
G 451 /- /- /- /493 /-
E 300 /- A /- /223 /-
D 174 /- /- /- /187 1-
Wind reactions based on MWFRS
G Brg Width = 11.3 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing G is a rigid surface.
Bearing G requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 133 - 214 C - D 76 - 60
B - C 731 -482
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
G- F 465 -723 F- E 0 0
A - G 204 -120
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
G - B 655 -280 C - F 753 -485
-WARNING- Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any.TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPIA. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kiistam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the ]Be, local building code and TPIA.- The approval of the TDD and any field # 88906- . -
use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out In the TOO and the practices and 4451 St Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI.1.
Cnnvriaht 0 201fi A-1 Roof To- - Renmdurlion of thle domanent. in am fnrm. is nmhihtted without the written nnrmircinn of A-1 Roof Tnrecac.
Job
CHHS3B
I russ
R
I russ I ype Uty I rly
EJAC 17 1
UZ/U9/ZUZ'I 2603
►i
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
3-15�'I6"
SEAT PLATE REQ.
�-- 1'6" --�
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Lt Slider: 2x6 SP #2; block length = 2.750'
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 6.50
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Detl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.096 B 589 36(
VERT(CL): 0.087 B 647 24(
HORZ(LL): -0.066 B - -
HORZ(TL): 0.074 B - -
Creep Factor: 2.0
Max TC CSI: 0.718
Max BC CSI: 0.413
Max Web CSI: 0.238
Wgt: 25.9 Ibs
VIEW Ver: 20.01.01A.0724.12
C
T
to
P
CV
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
E 364 /- 1- /255 /177 /159
D 82 P P /45 /4 /-
C 122 P P /45 /147 P
Wind reactions based on MWFRS
E Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 449 -1142 B - C 38 -126
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
E- D 0 0 A- E 1190 -403
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
E - B 1091 -497
'"WARNING- ' Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of. the IRC, the IBC, local building code. and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss,- including handlings storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. Allnotesset out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss
Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer Is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined In TPI-1.
Cnnvrinht Q 2016 A-1 Rnnf Tn,-- Renmdurtien of this dmiment. in am fnrm. is nmhihited wtthnut the written nermissinn of A-1 Rnnf Tni. ses,
CHHS3B J8 EJAC 11 1
R
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
T
3-15 i16°
SEAT PLATE REQ.
1 r6" --�
Wind Criteria
Wind Sid: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 :SP 2400f-2.OE + SP M-31:;
Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:;
Lt Slider: 2x6 SP #2; block length = 2.750'
Puriins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 8.50
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria .
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
A1.1%
Defi/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): -0.166 B 485 36i
VERT(CL): 0.172 B 467 24,
HORZ(LL): -0.116 B - -
HORZ(TL): 0.130 B -
Creep Factor: 2.0
Max TC CSI: 0.592
Max BC CSI: 0.353
Max Web CSI: 0.298
Wgt: 34.3 Ibs
VIEW Ver. 20.01.01A.0724.12
C
♦ Maximum Reactions (Ibs)
Gravity
Loc R+ / R- / Rh
Non -Gravity
/Rw /U /RL
E 437 /- /- /292 /220 /209
D 122 /- P /66 /5 P
C 181 /- /- /72 /210 /-
Wind reactions based on MWFRS
E Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - B 581 -1470 B - C 57 -164
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
E- D 0 0 A- E 1494 - 531
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
E - B 1395 - 654
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal an any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building Is the Rama Pranav Mstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
' - use of the Truss, including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C nvdnht 0 2016 A-1 Rnnf Tn..-- Rrnmdudinn of this damiment. in env fnnn. is nmhihhed withnut the written nenn Ginn of A-1 Rnnf Tries.
JOD
CHHS3B
I lubb
J8B
I I Ubb I yp. ..pry I r lY v�iv�rcvc ,
MONO 1 1
2605
1. r
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BOLL: 0.00
BCDL: 10.00
Des Ld: 40.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
3-1Ts-
P]
T
io
1
1 69-7/16" -1— 1'8-9/16"--�
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Lt Slider: 2x6 SP #2; block length = 2.750'
Plating Notes
All plates are 2X4(C6) except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 8.50
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
8'6"
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or `=PLF
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): -0.055 B 999 360
Loc R+ / R- / Rh / Rw / U / RL
G 350 /- P /245 1131 /148
Rep Factors Used: Yes
VERT(CL): 0.070 B 857 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.038 B - -
H' 56 P /- /29 /29 !-
Plate Type(s):
HORZ(TL): 0.047 B - -
Wind reactions based on MWFRS
WAVE
Creep Factor: 2.0
G Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.557 '
H Brg Width = 76.0 Min Req = -
Max BC CSI: 0.459
Bearings G & G are a rigid surface.
Bearings G & G require a seat plate.
Max Web CSI: 0.304
Maximum Top Chord Forces Per Ply (Ibs)
Wgt:37.1 Ibs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 20.01.01A.0724.12
A - B 432 -1049 C - D 0 -33
B - C 37 - 204
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
G-F 10 -26 F-E 0 0
A - G 1091 - 385
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
G - B 924 -487 C - F 640 -254
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the.TDD to be valid.. As a Truss Design Engineering (i.e. Specialty Engineer), the.seal on any TDD. represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of.the.Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field . 4.88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties Involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
r—vri.ht 0 2016 A-1 Rnnf Trusses — Renmd-jinn of this dnmunent. In env form. is nmhihitad wilhnut the written n—issian of A-1 Ronf Trusses.
10/28/2020 HIP/ KING JACK (TYPICAL) STDL 01.0
Aa#= A-1 ROOF
= TRUSSES
A FLORIDACORPORATION
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
(772)409-1010
ATTACH END JACKS USING (4)
0.131" 0 TOE NAILS AT TOP
CHORD & (3) 0.131" 0 TOE
NAILS AT BOTTOM CHORD.
ATTACH KING JACK USING
(3) 0.131" 0 TOE NAILS AT
TOP CHORD & BOTTOM
CHORD.
ATTACH CORNER JACKS USING
(2) 0.131" 0 TOE NAILS AT TOP &
BOTTOM CHORDS (TYP).
CORNERSET GENERAL SPECIFICATIONS:
MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60,
MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT.
Rama Pranav Mstam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
F.It Pierce, FL 34946
5/28/2020 HIP/ KING JACK (HVHZ) STDL,y 0,2.2,
�A-1 ROOF
= TRUSSES
A FLORIDA CORPORATION
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL. 34946
(772)4019-1010
ATTACH KING & END JACK
WITH (1) THJA26 HANGER
OR EQUIVALENT AT
BOTTOM CHORD
ATTACH KING & END JACKS
WITH (1) LSTA12 TWIST STRAP
AT TOP CHORD WITH (10) 1Od
NAILS PER STRAP (MIN.) & (3)
0.131" 0 TOE NAILS.
ATTACH CORNER JACKS &
STD. JACKS WITH (1) LSTA12
TWIST STRAP AT TOP CHORD
& BOTTOM CHORD WITH (10)
1 Od NAILS PER STRAP
MINIMUM (TYP).
HIGH VELOCITY HURRICANE ZONE CORNERSET SPECIFICATIONS:
MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60'
MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT.
NOTE: IN ADDITION TO STRAPPING TOE- NAIL
BOTH CHORDS OF CORNER JACKS TO CARRYING
MEMBER PER THE FOLLOWING SCHEDULE:
• 2X4: (2) 0.131" 0 TOE NAILS
• 2X6: (3) 0.131" 0 TOE NAILS
LSTA12 TWIST STRAP WITH 1 OD NAILS,
MIN. (10). SEE MFR'S
RECOMMENDED CONNECTION.
HIP, OR KING JACK (TYP.)
JACK, OR CORNER JACK (TYP.)
IMPORTANT NOTE:
CONNECTION DESIGNED IN ACCORDANCE WITH FBC 2321.6-
2321.7 PROVIDING METAL STRAPPING (FLORIDA APPROVED
PRODUCT) TO RESIST MIN. 700LB UPLIFT AT ALL CONNECTIONS
IN HIGH VELOCITY HURRICANE ZONE.
Rama Pranav Kristam, P.E.
11188906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946 -
FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD
1' - 3' MAX.
DIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS THE RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE.PROJECT ENGINEER/ARCHITECT
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
HORIZONTAL BRACE
(SEE SECTION A -A)
TRUSSSES 0
F_ 24' O.C.
2XG DIAGONAL BRACE SPACED 48'
D.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - 10d COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIND.
PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
\ BRACE AND THE TWO TRUSSES ON
\EITHER SIDE AS NOTED. TOENAIL
\ BLOCKING TO TRUSSES WITH (2) -
\ 10d NAILS AT EACH END. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
END WALL
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131'
X 3') NAILS SPACED 6' D.C.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
URAL
TRUSS
STRUCTURAL / AN ADEQUATE DIAPHRAGM DR OTHER METHOD OF BRACING
GABLE TRUSS / MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR/
STRUCTURAL GABLES WITH INLAYED
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT ADDRESSED HERE.
/
STANDARD GABLE /
TRUSS
/
Rama Pranav Mstam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
12/23/19 PIGGY -BACK TRUSS STDTL0A.1
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, Fl. 34W
772-409-1010
PIGGY -BACK DETAIL (TYPICAL)
180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
OR...
160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
IMPORTANT NOTE:
TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY
BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL
PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY
RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS.
MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C.
DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA,
STEEPLE, CHIMNEY OR DRAG STRUT LOADS.
**REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE
TRUSS SPECIFICATIONS.**
PIGGY -BACK TRUSS. (REFER
TO ACTUAL TRUSS DESIGN
DRAWINGS FOR ADDITIONAL
INFORMATION.)
2'-0"
MAX
OPTION NO. 1 - TEE-LOK
3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED
AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO
PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM
EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH
6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE
MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8"
TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2
PLATES).
OPTION NO.2 - APA RATED GUSSET:
8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS
EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d
COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT
CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP
CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C.
FRONT TO BACK FACES. MINIMUM TWO (2 EA.)
CONNECTIONS AT EACH TRUSS.
OPTION NO.3 - 2X4 VERTICAL WOOD SCAB:
2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE.
ATTACH AT 8'-0" O.C. w/6 (EACH) 1Od BOX NAILS (0.128"
x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND
3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE
STAGGERED 4'-0" O.C. FRONT TO BACK FACES.
MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS.
OPTION #1: TEE-LOK MULTI -USE
CONNECTION PLATE.
OPTION #2: APA RATED GUSSET.
OPTION #3: 2X4 VERT. SCAB.
ATTACH EACH PURLIN TO TOP
CHORD OF BASE TRUSS. PURLIN
& CONNECTIONS BY OTHERS.
BASE TRUSS. (REFER TO TRUSS
DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.)
PURLINS SPACED ACCORDING
TO MAX. SPACING OF TOP
CHORD OF BASE TRUSS.
SPACING IS NOT TO EXCEED 24"
O.C. & PURLINS TO BE LOCATED
AT JOINT OF EACH BASE TRUSS.
** IMPORTANT NOTE **
THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES
SPACED AT 24" O.C. OR LESS.
Rama Pranav Kristam, P.E.
# 68906
4451 St Lucie Blvd, Suite 201
Fort Pierce, FL 34946 -
,DULY 17, 2017
TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 1 Od
2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR
EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL "A".
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS - 01.
GABLE END, COMMON
7. VALLEY STUD, SPACING NOT TO EXCEED 48" O.C.
TRUSS, OR GIRDER l
TRUSS 1
ATTACH 2X4 CONTINUOUS #2
SYP TO THE ROOF W/ TWO
SIMPSON SDS25412 (1/4" X 4.5")
OR EQUIVALENT WOOD SCREWS
INTO EACH BASE TRUSS.
13�1�1
BASE TRUSSES
X CIVU, UU11nMUIN
-S, OR GIRDER TRUSS
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT= 30 FEET
ROOF PITCH = MINIMUM 3112 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
MAX SPACING = 24" O.C. (BASE AND VALLEY)
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
Rama Franey Mstam, RE 1
# 88906
4451 St Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 5, 2018 1 TRUSSED VALLEY SET DETAIL I STDTL06 -
` GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
� 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01.
4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
FORT PIERCE, FL 34946 TRUSS, 'OR GIRDER
772-409.1010 TRUSS
SECURE
W/(
VALLEY TRUSS y II II II II B E TER SSES
(TYPICAL) II
v" s i g" r
(NO SHEATHING) N.T.S.
GABLE END, COMMON
TRUSS, OR GIRDER
VALLEY TRUSS TRUSS
P 12 �\ (TYPICAL)
SEE DETAIL "A"
BELOW (TYP.)
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS #2
MAX TOP CHORD TOTAL LOAD = 50 PSF
SYP TO THE ROOF W/ TWO
MAX SPACING = 24" O.C. (BASE AND VALLEY)
SIMPSON SDS25300 (1/4" X 3")
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
OR EQUIVALENT WOOD
SCREWS INTO EACH BASE
TRUSS.
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
JULY 17, 2017 ' ' """"" v "` ' `,` '
"" STDTL07
(HIGH WIND VELOCITY)
w
A-1 ROOF TRUSSES
4451 ST_ LUCIE BLVD.
FORT PIERCE, FL 34946
T72-409-1010
ATTA(
WIND DESIGN PER ASCE 7-98, ASCE 7-
WIND DESIGN PER ASCE 7-10: 170 MPI
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PSI
MAX SPACING = 24" O.C. (BASE AND VP
SUPPORTING TRUSSES DIRECTLY UNUMM VMLLM r I RUOOCO IVIUO I o=
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 1 O" ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
NON -BEVELED
BOTTOM CHORD
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
- CLIP MAYBE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6/12 PITCH NON -BEVELED
BOTTOM CHORD
0 0
000
CLIP MUST BE APPLIED TO —/
THIS FACE WHEN PITCH
EXCEEDS 6/12 (MAXIMUM
12/12 PITCH) RemaPre wKds P.E.
1t 88906
4451 St. Lucie Blvd. Suite 201
FEBRUARY 17, 2017 I STANDARD GABLE END DETAIL I STDTL08Y
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
7z;
VERTICAL
STUD
A-1 ROOF TRUSSES SECTION B-B
4451 ST. LUCIE BLVD,
FORT PIERCE, FL 34946
772409-1010 FSH
RUSS GEOMETRY AND CONDITIONS
OWN ARE FOR ILLUSTRATION ONLY.
DIAGONAL BRACE 4' - 0' O.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
VERTICAL
2X6 SP OR SPF
STUDP2X4
#2 DIAGONAL
BRACE
(4) - 16d
NAILS16d
NAILS
SPACED 6' O.C.
(2) 10d NAILS
INTO 2X62X6
SP OR
SPF #2
2X4 SP OR
SPF #2L
HORIZONTAL
NAILED TO
RTICALS
SECTION A -A
W/(4) - 10d NAILS
12 PROVIDE 2X4 BLOCKING BETWEEN
JA Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
* WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
(4) Bd NAILS MINIMUM,
B 3X4 = PLYWOOD SHEATHING TO
2X4 STD SPF BLOCK
*
v
DIAGONAL BRACING ** L - BRACING REFER
REFER TO SECTION A -A TO SECTION B-B 24' MAX.
NOTE:
/
1.
MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
2.
CONNECTION BETWEEN BOTTOM CHORD OF GABLE END. TRUSS AND WALL TO 12' MAX.
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3.
BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
'
SYSTEM.
4.
'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR
5.
BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C.
DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
/
AT4'-0'D.C.
6.
CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT
THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
-
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
7.
GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240.
B.
THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. OIAG. BRACE
9.
DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS
TRUSSES. IF NEEDED
10.
10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X3.5' COMMON WIRE NAILS
RESPECTIVELY.
11.
SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(2) DIAGONAL
BRACES AT
1/3 POINTS
MAXIMUM STUD LENGTH
2X4 SP 431 STUD
12" O.C.
3-8-10
5-6-11
6-6-11
11-1-13
2X4 SP #31 STUD
16" O.C.
3-3-10
4-9-12
6-6-11
9-10-15
2X4 SP #31 STUD
24" O.C.
2.8-6
3-11-3
54.12
8-1-2
2X4SP#2
12"O.C.
3-10-15
5.6-11
6-6-11
11-8-14
2X4 SP 42
16" O.C.
3.6.11
4-9.12
6-6.11
10-8.0
2X4 SP #2
24" O.C.
3-14
3-11-3
6-2-9
9-3-13
DIAGONAL BRACES OVER 6' - 3- REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER
SOX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
ROOF
SHEATHING
(2) - 10d
NAILS
TRUSSES @ 24' O.C.
2X6 DIAGONAL BRACE
SPACED 48' O.C. ATTACHED
TO VERTICAL WITH (4) -
16d NAILS, AND ATTACHED
TO BLOCKING WITH (5) -
10d NAILS.
HORIZONTAL BRACE
(SEE SECTION A -A)
END WALL
Rama Pranav Kristam, P.E.
# 6e906
4451 St. Lucie Blvd, Suite 201
Fart Pierce, FL 34946 -
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7-10 190 MPH
DURATION OF LOAD INCREASE :1.60
STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
CONNECTION OF BRACING IS BASED ON MWFRS.
DETA
TEB'RUARY 17, 2017 I T WIDTH 2XIBRACEEON Y IL I STDTL09
40TES:
r-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACINE
S IMPRACTICAL. T-BRACE / I -BRACE MUST COVER 90% OF WEB LENGTH.
PHIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TC
:ONTINUOUS LATERAL BRACED WEBS.
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE. FL 34946
772-409-1010
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2X8
10d
6' O.C.
NOTE: NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON
TWO-PLY TRUSSES NAIL TO BOTH PLIES)
NAILS
SPACING
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
T-BRACE / I -BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS NAILS
WEB
NAILS WEB
I —BRACE T—BRACE
Rama Pranav Kristam, P.E.
# 88906
SECTION DET A I L ort Pierce, FLd�34946Z°'
FEBRUARY 17, 2017
LATERAL BRACING RECOMMENDATIONS I STDTL10r. - (
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET
ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
AA ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW.
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
772409.1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM ENO TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
ANCHOR TO ATTACH WEB WITH (3) - 10d SCAB WITH (3) - 10d
TO TOP CHORD NAILS (0.131' X 3') NAILS (0.131' X 3'). r ATTACH TO VERTICAL
NAILS (01313WITH )X 3')
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
USE METAL FRAMING ATTACH TO VERTICAL
ANCHOR TO ATTACH WEB WITH (3) - SOd
TO BOTTOM CHORD NAILS (0131' X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) - 10d NAILS (0.131'
X 3') IN EACH CHORD
ATTACH TO VERTICAL
SCAB WITH (3) - 10d
NAILS (0.131' X 3')
TRUSS 2X6 4' - 0' WALL
STRONGBACK (TYPICAL SPLICE) (BY OTHERS)
ATTACH TO CHORD
WITH (2) #12 X 3'
WOOD SCREWS
(0.216' DIA.)
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRDNGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
Rama Pranav Kristam, P.E.
# 66906
4451 St. Lucia Blvd, Suite 201
Fort Pierce, FL 34946
I I EBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL I STDTLII
A-1 ROOF TRUSSES
4461 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772.409-1010
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
DIA
SP
OF
HF
SPF
SPF-S
.131
88.0
80.6
69.9
68.4
59.7
o
.135
93.5
85.6
74.2
72.6
63.4
J
.162
108.8
99.6
86.4
84.5
73.8
ri
128
74.2
67.9
58.9
57.6
50.3
c�
.131
75.9
69.5
60.3
59.0
51.1
Z
0
.148
81.4
74.5
64.6
63.2
52.5
in
N
M
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL. SIDE VIEW
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. (2X4) 3 NAILS
EXAMPLE: NEAR SIDE
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
NEAR SIDE
FOR LOAD DURATION INCREASE OF 1.15: NEAR SIDE
3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (OOL) = 291.5 LB MAXIMUM CAPACITY
ANGLE MAY
VARY FROM
30' TO 60'
45.00'
ANGLE MAY
VARY FROM
30' TO 60°
45.00'
SIDE VIEW
(2X6) 4 NAILS
ANGLE MAY
VARY FROM
30' TO 60'
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
St. LuLfp`I
'ort Pierce,
45.000
Mstam, P.E.
906
31vd, Suite 201
EL 34946 '
FEBRUARY 17, 2017 ( UPLIFT TOE -NAIL DETAIL 1 STDTL12 "' z
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
NOTES:
TOE -NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF-S
0
.131
59
46
32
30
20
Z
O
J
.135
60
48
33
30
20
LQ
.162
72
58
39
37
25
J
2
O
.128
54
42
28
27
19
F-
O
Z
Z
JO
.131
55
43
29
28
19
LLJ
.148
62
48
34
31
21
J
J
N
Q
M
Z
.120
51
39
27
26
17
0
Z
.128
49
38
26
25
17
O
131
51
39
27
26
17
O
.148
57
44
31
28
20
1
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30° WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE
FOR WIND DOL OF 1.33:
3 (NAILS) X 37 (LB/NAIL) X 1.33 COOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
*** USE (3) TOE -NAILS ON 2X4 BEARING WALL
*** USE (4) TOE -NAILS ON 2XG BEARING WALL
NEAR SIDE
FAR S:
Z
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
[L
NAIL
NAIL
ry Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
oR Pierce, FL 34946
SIDE -VIEW
END VIEW
FEB.RUARY 5, 2016
TYP 2x2 NAILER ATTACHMENT I STDTL13
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
1.0 X 4
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
Rama Pranav Kristam, P.E.
d 88906
4451 St Lucie Blvd, Suite 201
Fort Pierce, FL 34946
April 11, 2016
TYPICAL ALTERNATE BRACING DETAIL
FO EXTERIOR FLAT GIRDER TRUSS
STDTL14
,n 4 1
A-1 ROOFTRUSSES
4451 ST..WCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
12
VARIES L,,,-�
(4) 12d
MAX 30" (2'-6")
2x6 #2 SP (Both Faces)
24" O.C.
SIMPSON H5
# 88906
4451 SL Lucie Blvd, Suite 201
Fort Pierce, FL 34946
STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND
1:EBE�UARY 17, 2017 DAMAGED OR MISSING CHORD SPLICE PLATES STDTL15
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK *
X
(INCHES)
MAXIMUM FORCE (LBS) 15% LOAD DURATION
SP
DF
SPF
HF
20
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
24"
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30"
2194
3291
2007
3011
1697
2546
1738
2608
32
48
36"
2681
1 4022
2454
1 3681
2074
3111
2125
3187
38
57
42"
3169
4754
2900
4350
2451
3677
2511
3767
44
66
46"
3657
5485
3346
5019
2829
4243 j
28911
4347
DIVIDE EQUALLY FRONT AND BACK
ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE
ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3').
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' D.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER ENO DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C
•10d NAILS NEAR SIDE
+10d NAILS FAR SIDE
X' MIN �-
6' MIN
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO
THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT
AND A MINIMUM OF S' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE).
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID
Rama Pranav Mstam, P.E.
UNUSUAL SPLITTING OF THE WOOD.
#66906
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID
4451 St. Lucie Blvd, Suite 201
LOOSENING OF THE CONNECTOR PLATES AT -THE JOINTS OR SPLICES. •
Fart Pierce, FL 34946
5. THIS REPAIR.. IS BE. USED FOR PLY TRUSSES IN THE 2X_ ORIENTATION ONLY.
-.TO -SINGLE
6. THIS REPAIR IS LIMITEO.TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.-
FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTL16r
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772.409-1010
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 115
SPACING: 24' O.C.
TOP CHORD: 2X4 OR 2X6
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
END BEARING CONDITION
\[1114�
1. ATTACH 2X_SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' OIA. X 3') SPACED 6' O.C.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24'
O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP'CHOR13
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES
Rama Pranav Mstam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
Building Permit # Owners Name HABITAT FOR HUMANITY
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
0
Applicant: 0
UA
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Ems+
Windows
+33.5/-36.3
+80/-80
LAWSON
SH-7700
20-0813.07
IMPACT
1/4" TAPCON SPACED PER MANUFACTURER INSTALLATION
Mullions
Fixed Glass
Block Glass
Skylights
Sliding Glass Doors
Swing Type Doors
+32.0/-34.8
+67/-67
THERMA-TRU
FL20468.1
N/A
1/4" TAPCON 13" O.C. MAX. FOLLOW MANUFACTURER INSTALLATION
French Doors
Garage Doors
+29.7/-32.5
+31.3/-34.9
HAAS
2580 SERIES
FL16660.11
N/A
1/4' TAPCONS WITH V WASHER @7 24' MAX. FOLLOW MANUFACTURER INSTALLATION
Hurricane Protection
Roof Ventilation
LOMANCO
16-0510.25
N/A
(32) 8d NAILS @4" O.C.
Roofing Material
HVHZ
TAMKO
FL18355.1
N/A
6" NAIL PATTERN
Revised 07/22/2014
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adeq ViV'si a> !tJie
wind loads and forces specified by current code provisions.CN,���`� ��,:•' E A " ��'�.�
fl crn9rceny.�".d oy Wren m says ` �. J
Ryan M Bays DN;E=Ryan.Bays, eflnlnLLO,L.neortPie yenMBays, y(/
0.Whole Hcuse Englneering LLC, L-Fort Pierce, S.Flsrida1 C.Us.
v y Ryan M Bayer Rea'sen:iamaParovN9 Wsdecumem ! T No.,
Name: Signature: Date:2021.052409:43:01-04'00'
PE 91231 5/24/2021
Design Prof: Cert. No. Date: OF
��