HomeMy WebLinkAboutAPPROVED A1.2 REFLECTED CEILING PLANW / D
STACKED36"FRIDGE24"
D.W.
U.C.
MICRO
(OPTIONAL)
TRASH
BIN
WH
ELECT. RANGE
W/ HOOD
PH
EF
VP
VP
GFCI
GFCI
EFEF
VP VP
DASH LINE
INDICATES
ROOF
OVERHANG
MAIN ELECTRICAL
SERVICE METER
POOL EQUIPMENT
W/ POWER DISC.
AND POOL PANEL
A/C COMP. #1 W/DISC. ON MIN.
6" HIGH CONCRETE EQUIPMENT PAD
(MANTAIN 6" MIN. ABOVE ADJACENT
GRADE)
SPRINKLER
SYSTEM W/
TIMER
LAUNDRY
DINING
GUEST ROOM
OFFICE
HIS
COVERED
ENTRY
MASTER
BEDROOMMASTER BATH
LIVING ROOM
FOYER
COVERED LANAI
POOL
16'-9" X 23'-0"
GUEST BATH PWDR
CLOSET
2 CAR GARAGE
20'-0" X 22'-0"
KITCHEN
9'-4" CLG
9'-4" CLG
HERS
CLOSET
MATER HALL
WET DECK
POOL DECK
9'-4" CLG
9'-4" CLG
9'-4" CLG
9'-4" CLG
9'-4" CLG
9'-4" CLG
9'-4" CLG
9'-4" CLG 9'-4" CLG 9'-4" CLG
POOL BY OTHERS
UNDER SEPARATE
PERMIT
13'-3" CLG
CLOSET
9'-4" CLG
IMPORTANT NOTE:
1. THIS RCP PLAN IS FOR GRAPHIC INFORMATION ONLY.
REFER TO MEP ENGINEERING 'E' SHEETS FOR COMPLETE INFORMATION.
VERIFY IN THE FIELD
CEILING HEIGHT AT AREA
OF BATH TUB BEFORE ANY
COMMENCEMENT OF WORK
1
AIR HANDLER
ON COFFERED
CEILING.
COORDINATE
WITH ROOF
FRAMING
1
1. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH
THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE (NEC),
AND THE LATEST EDITIONS OF ALL LOCAL CODES, RULES AND
ORDINANCES HAVING JURISDICTION.
2. AS A MINIMUM, ALL EQUIPMENT SHALL MEET APPLICABLE
STANDARDS, FOR TYPE OF EQUIPMENT AND INTENDED USE, OF
THE FOLLOWING: a. AMERICAN NATIONAL STANDARDS INSTITUTE
(ANSI). b. ILLUMINATING ENGINEERS SOCIETY (IES). c.
AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). d.
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA).
NOTE: THESE STANDARDS ARE SUBORDINATE TO CODES AND
STANDARDS SET BY U.L.
3. IT SHALL BE UNDERSTOOD THAT ALL WORK PERFORMED
SHALL BE BY A LICENSED ELECTRICAL CONTRACTOR IN A
FIRST CLASS WORKMANLIKE MANNER. CONTRACTOR
SHALL MEET ALL REQUIREMENTS SET FORTH BY ANY LOCAL
ORDINANCE AND GOVERNING AUTHORITIES.
4. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED
INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND
PROPERTY DAMAGE FOR THE DURATION OF THE WORK.
5. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND
WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT
LESS THAN (1) YEAR FROM DATE OF ACCEPTANCE, U.O.N..
6. IT SHALL NOT BE THE INTENT OF THESE PLANS AND/OR
SPECIFICATIONS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION.
THE CONTRACTOR SHALL BE EXPECTED TO FURNISH AND INSTALL
ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE
ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE
PLACED IN PROPER WORKING ORDER.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING TO
ORIGINAL CONDITIONS, ANY AND ALL DAMAGES TO BUILDING
SURFACES, EQUIPMENT, ETC. CAUSED DURING THE PERFORMANCE
OF WORK.
8. ALL CONDUCTORS SHALL BE COPPER, TYPE THHN/THWN
EXCEPT WHERE OTHERWISE REQUIRED BY U.L. OR CODES.
MINIMUM WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL
WIRING.
9. ALL CONDUCTORS SHALL BE IN CONDUITS. ALL CONDUITS SHALL BE
GALVANIZED RIGID STEEL (GRS) EXCEPT THAT: (a) PVC CONDUITS
MAY BE USED UNDERGROUND PROVIDED ELBOWS AND RISERS ARE
GRS, WHERE SUBJECT TO PHYSICAL DAMAGE (b) ELECTRICAL METALLIC
TUBING (EMT) MAY BE USED IN OR ON WALLS OR CEILINGS WHERE NOT
SUBJECT TO MECHANICAL DAMAGE, DAMP OR CORROSIVE CONDITIONS,
(d)LIQUID TIGHT FLEXIBLE CONDUIT WHERE REQUIRED, (d) FLEXIBLE
METALLIC CONDUIT (MC CABLE W/GROUNDING CONDUCTOR), WHERE
REQUIRED IN DRY LOCATIONS ONLY. ALL CONDUITS IN HAZARDOUS
AREAS (PER NEC) SHALL MEET THE REQUIREMENTS OF NEC CHAPTER 5
10. ALL CONDUIT RUNS ARE SHOWN DIAGRAMATICALLY. THE EXACT
ROUTING SHALL BE DETERMINED IN THE FIELD. UNLESS NOTED OTHERWISE.
11. FOR TELELPHONE SYSTEMS: A. PROVIDE GROUNDING FOR ALL TELEPHONE
OUTLETS AND EQUIPMENT PER REQUIREMENTS OF THE TELEPHONE
COMPANY. B. COORDINATE INSTALLATION OF ALL TELEPHONE OUTLETS,
RACEWAYS, ENCLOSURES AND BACKBOARDS WITH TELE. CO. C. VERIFY
LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY. PROVIDE
SERVICE CONDUIT TO BLDG. FROM SERVICE POINT PER TELCO. INSTRUCTIONS.
D. MARK TERMINATIONS OF TELEPHONE CONDUIT AS DIRECTED BY THE
TELEPHONE COMPANY. E. VERIFY LOCATION OF TELEPHONE SERVICE WITH
TELEPHONE COMPANY PRIOR TO SUBMITTING BID. F. USE EXTERIOR
GRADE 3/4" PLYWOOD BACKBOARDS FOR MOUNTING TELEPHONE
EQUIPMENT AND TERMINAL STRIPS. PAINT BOARD ON ALL SIDES AND EDGES
WITH TWO COATS OF FLAT BLACK ASPHALT PAINT.
13. ALL CIRCUIT BREAKERS SHALL BE INVERSE TIME TYPE
(THERMAL- MAGNETIC). TWO AND THREE POLE CIRCUIT
BREAKERS SHALL BE COMMON TRIP. TIE HANDLES ARE NOT
PERMITTED.
14. ALL ELECTRICAL EQUIPMENT SHALL BE RAINTIGHT (NEMA 3R)
WHERE EXPOSED TO THE WEATHER. ALL FLEX CONDUITS CONNECTED
TO SUCH EQUIPMENT SHALL BE LIQUIDTIGHT.
15. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS,
CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS
AND SPECIAL ENCLOSURES AS REQUIRED FOR OTHER
CLASSIFIED AREAS. U.O.N.
16. LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS AND PENDANT
LUMINAIRES OR LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOTHES CLOSETS.
AS PER NEC 410.10(D).
17. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. NEC 406.12; FBC RE4002.14
18 VERIFY IN THE FIELD LOCATION OF TELEPHONE RISER BEFORE ANY COMMENCEMENT
OF WORK.
19 ALL LIGHTS ARE TO BE ON LUTRON DIMMABLE SWITCHES.
20 ALL RECEPTACLES ARE TO BE IN THE BASEBOARD AS SHOWN ON THE
CONSTRUCTION DETAILS DWGS.
21 ALL STRIP WALL LIGHTS AT KITCHEN ARE UNDERCOUNTER LOW VOLTAGE LED LIGHTS.
22 CONTRACTOR TO WORK WITH INTERIOR DESIGNER ON DETAIL ON DETAIL FOR COVE /
ROPE SOFFIT LIGHTING.
23 ALL BATHROOMS AND KITCHEN / POWDER ROOM CIRCUITS ARE TO BE DIRECT TO
PANEL.
24 ALL ELECTRICAL IN THE AREAS OF RENOVATION WILL BE BROUGHT UP TO CURRENT
CODE. THIS INCLUDES KITCHEN COUNTERTOP RECEPTACLES, SMOKE ALARMS ETC.
THESE ELECTRICAL UPGRADES ARE SHOWN ON THE SUBMITTED PLANS. THE
LOCATION OF THE EXISTING ELECTRICAL PANEL AND SERVICE SIZE IS SHOWN ON THE
SUBMITTED DRAWINGS.
25 REMOVED
26 CONTRACTOR/INTERIOR DESIGNER/OWNER TO ENSURE AT LEAST 75% OF ALL
PERMANENTLY INSTALLED FIXTURES HAVE HIGH EFFICIENCY BULBS PER 2014 FBC
ENERGY CONSERVATION SECTION.
ELECTRICAL NOTES
SPECIAL NOTES:
1. CONTRACTOR SHALL PREPARED PANEL SCHEDULE AND INDICATE LIGHTNING AND
POWER CIRCUIT LABELS/NUMBERS ON FLOOR
PLAN WITH THE AS-BUILT DRAWINGS PRIOR TO
FINAL INSPECTION.
2. CONTRACTOR SHALL COMPLY WITH FBC (C408.2.5.1). PROVIDE OWNER WITH A RECORD
SET DRAWING OF COMPLETE INSTALLATION DRAWINGS.
3. CONTRACTOR SHALL COMPLY WITH FBC (C408.2.5.2). PROVIDE OWNER WITH
OPERATIONAL MANUALS AND MAINTENANCE MANUALS.
4. CONTRACTOR/INTERIOR DESIGNER/OWNER TO ENSURE AT LEAST 75% OF ALL
PERMANENTLY INSTALLED FIXTURES HAVE HIGH EFFICIENCY BULBS PER 2014 FBC
ENERGY CONSERVATION SECTION.
SHEET NUMBER
REVISIONS
This drawing is property of GMK, PALM BEACH,
FLORIDA. Any use of this drawing or the design
information hereon without written authorization of GMK
is strictly prohibited.
c 2021 GMK
PALM BEACH, FLORIDA
GMK
PLANNING - ZONING - DESIGN
G M KAGAN FAIA
205 WORTH AVENUE 201-111
PALM BEACH FL 33480
CELL: 203 988 1838
GMK@GMKPZD.COM
SOSNOWSKI RESIDENCE
Project Location:
3902 DUNESIDE DRIVE
FT PIERCE, FL 34949
CONSULTANTS
Project #: 2002
Architect: GERALD M. KAGAN
DATE : 08-25-2021
SHEET NAME:
SCALE: AS NOTED
PERMIT SET
INTERNATIONAL CONSULTING ENGINEERS &
DESIGN, LLC
4310 WEST BROWARD BLVD.
PLANTATION, FL 33317
T 561.707.6795 F 954.797.2847
CONTACT: JOE SPASOVSKI, P.E.
UNISONSTRUCTURALDESIGN
7522 WILES RD, SUITE B204
CORAL SPRINGS, FL 33067
PHONE: (954) 323-3746
MOBIL: (305) 298-0467
EMAIL:
UNISONSTRUCTURALDESIGN@GMAIL.COM
WEB:
UNISONSTRUCTURALDESIGN.COM
DATE : 10-06-2021
REFLECTED CEILING AND
ELECTRICAL PLAN
REFLECTED CEILING & ELECTRICAL PLAN
SCALE: 1/4" = 1'
A1.2
N
SW E
REFLECTED CEILING PLAN NOTES
1.ARCHITECTURAL LIGHTING PLAN SUPERCEDES ELECTRICAL PLAN FOR
LOCATIONS AND FIXTURE TYPE IF NOTED. COORDINATE WITH ELECTRICAL
PLAN AND NOTIFY ARCHITECT IF THERE ARE ANY DISCREPANCIES PRIOR TO
BID AND PURCHASING.
2.ALL ELECTRICAL FIXTURES TO BE PURCHASED AND SUPPLIED BY OWNER.
INSTALLED BY GENERAL CONTRACTOR.
3.G.C. TO PROVIDE BLOCKING AS REQUIRED TO SECURE ALL CEILING MOUNTED
FIXTURES AND DEVICES, TYP.
4.OWNER/ARCHITECT TO REVIEW ALL LIGHTING FIXTURE AND DEVICE
LOCATIONS IN FIELD PRIOR TO INSTALLATION.
5. ALL CEILING HEIGHT ARE FROM FINISH FLOOR U.O.N.
CEILING FINISHES:
"A" - 5/8" DENSARMOR PLUS TYPE "X" CEILING; PAINTED.
" B" - 5/8" DENSARMOR PLUS TYPE "X" TRAY CEILING; PAINTED.
" C" - 3/4" TONGUE AND GROVE CEILING WITH VAPOR BARRIER ON 5/8" EXTERIOR PLYWOOD, TEAK FINISH.
" D" - 3/4" SMOOTH STUCCO, 3-COAT, WITH WATERPROOFING EQUAL TO THEROSEAL" MASTERSEAL 583"
OR APPROVED EQUAL, PAINTED.
LATCH
CASING BEAD CASING
BEAD
PIVOT HINGE
214"1" RECESS
ACCESS OPENING
ACOUSTIC INSULATION
1
4" DIA. THREADED PENCIL - ROD
HANGERS
BLACK-IRON CHANNEL FRAMING
@ 4'-0" O.C. MAX
7
8" METAL FURRING HAT CHANNELS @
16" O.C.
(1) LAYER 58" G.W.B.V.I.F.TYPICAL DROP CEILING DETAIL3SCALE: 1 1/2" = 1'-0"
TYPICAL RECESSED DRYWALL ATTIC ACCESS DOOR2SCALE: 1/2" = 1'-0"
1 08/25/21 CLIENT CHANGES
2 10/05/21 BDC COMMENTS
2
3 10/21/21 BDC COMMENTS
3