Loading...
HomeMy WebLinkAboutAPPROVED A1.2 REFLECTED CEILING PLANW / D STACKED36"FRIDGE24" D.W. U.C. MICRO (OPTIONAL) TRASH BIN WH ELECT. RANGE W/ HOOD PH EF VP VP GFCI GFCI EFEF VP VP DASH LINE INDICATES ROOF OVERHANG MAIN ELECTRICAL SERVICE METER POOL EQUIPMENT W/ POWER DISC. AND POOL PANEL A/C COMP. #1 W/DISC. ON MIN. 6" HIGH CONCRETE EQUIPMENT PAD (MANTAIN 6" MIN. ABOVE ADJACENT GRADE) SPRINKLER SYSTEM W/ TIMER LAUNDRY DINING GUEST ROOM OFFICE HIS COVERED ENTRY MASTER BEDROOMMASTER BATH LIVING ROOM FOYER COVERED LANAI POOL 16'-9" X 23'-0" GUEST BATH PWDR CLOSET 2 CAR GARAGE 20'-0" X 22'-0" KITCHEN 9'-4" CLG 9'-4" CLG HERS CLOSET MATER HALL WET DECK POOL DECK 9'-4" CLG 9'-4" CLG 9'-4" CLG 9'-4" CLG 9'-4" CLG 9'-4" CLG 9'-4" CLG 9'-4" CLG 9'-4" CLG 9'-4" CLG POOL BY OTHERS UNDER SEPARATE PERMIT 13'-3" CLG CLOSET 9'-4" CLG IMPORTANT NOTE: 1. THIS RCP PLAN IS FOR GRAPHIC INFORMATION ONLY. REFER TO MEP ENGINEERING 'E' SHEETS FOR COMPLETE INFORMATION. VERIFY IN THE FIELD CEILING HEIGHT AT AREA OF BATH TUB BEFORE ANY COMMENCEMENT OF WORK 1 AIR HANDLER ON COFFERED CEILING. COORDINATE WITH ROOF FRAMING 1 1. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE (NEC), AND THE LATEST EDITIONS OF ALL LOCAL CODES, RULES AND ORDINANCES HAVING JURISDICTION. 2. AS A MINIMUM, ALL EQUIPMENT SHALL MEET APPLICABLE STANDARDS, FOR TYPE OF EQUIPMENT AND INTENDED USE, OF THE FOLLOWING: a. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). b. ILLUMINATING ENGINEERS SOCIETY (IES). c. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). d. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA). NOTE: THESE STANDARDS ARE SUBORDINATE TO CODES AND STANDARDS SET BY U.L. 3. IT SHALL BE UNDERSTOOD THAT ALL WORK PERFORMED SHALL BE BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. CONTRACTOR SHALL MEET ALL REQUIREMENTS SET FORTH BY ANY LOCAL ORDINANCE AND GOVERNING AUTHORITIES. 4. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 5. THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM DATE OF ACCEPTANCE, U.O.N.. 6. IT SHALL NOT BE THE INTENT OF THESE PLANS AND/OR SPECIFICATIONS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR SHALL BE EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING TO ORIGINAL CONDITIONS, ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT, ETC. CAUSED DURING THE PERFORMANCE OF WORK. 8. ALL CONDUCTORS SHALL BE COPPER, TYPE THHN/THWN EXCEPT WHERE OTHERWISE REQUIRED BY U.L. OR CODES. MINIMUM WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING. 9. ALL CONDUCTORS SHALL BE IN CONDUITS. ALL CONDUITS SHALL BE GALVANIZED RIGID STEEL (GRS) EXCEPT THAT: (a) PVC CONDUITS MAY BE USED UNDERGROUND PROVIDED ELBOWS AND RISERS ARE GRS, WHERE SUBJECT TO PHYSICAL DAMAGE (b) ELECTRICAL METALLIC TUBING (EMT) MAY BE USED IN OR ON WALLS OR CEILINGS WHERE NOT SUBJECT TO MECHANICAL DAMAGE, DAMP OR CORROSIVE CONDITIONS, (d)LIQUID TIGHT FLEXIBLE CONDUIT WHERE REQUIRED, (d) FLEXIBLE METALLIC CONDUIT (MC CABLE W/GROUNDING CONDUCTOR), WHERE REQUIRED IN DRY LOCATIONS ONLY. ALL CONDUITS IN HAZARDOUS AREAS (PER NEC) SHALL MEET THE REQUIREMENTS OF NEC CHAPTER 5 10. ALL CONDUIT RUNS ARE SHOWN DIAGRAMATICALLY. THE EXACT ROUTING SHALL BE DETERMINED IN THE FIELD. UNLESS NOTED OTHERWISE. 11. FOR TELELPHONE SYSTEMS: A. PROVIDE GROUNDING FOR ALL TELEPHONE OUTLETS AND EQUIPMENT PER REQUIREMENTS OF THE TELEPHONE COMPANY. B. COORDINATE INSTALLATION OF ALL TELEPHONE OUTLETS, RACEWAYS, ENCLOSURES AND BACKBOARDS WITH TELE. CO. C. VERIFY LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY. PROVIDE SERVICE CONDUIT TO BLDG. FROM SERVICE POINT PER TELCO. INSTRUCTIONS. D. MARK TERMINATIONS OF TELEPHONE CONDUIT AS DIRECTED BY THE TELEPHONE COMPANY. E. VERIFY LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY PRIOR TO SUBMITTING BID. F. USE EXTERIOR GRADE 3/4" PLYWOOD BACKBOARDS FOR MOUNTING TELEPHONE EQUIPMENT AND TERMINAL STRIPS. PAINT BOARD ON ALL SIDES AND EDGES WITH TWO COATS OF FLAT BLACK ASPHALT PAINT. 13. ALL CIRCUIT BREAKERS SHALL BE INVERSE TIME TYPE (THERMAL- MAGNETIC). TWO AND THREE POLE CIRCUIT BREAKERS SHALL BE COMMON TRIP. TIE HANDLES ARE NOT PERMITTED. 14. ALL ELECTRICAL EQUIPMENT SHALL BE RAINTIGHT (NEMA 3R) WHERE EXPOSED TO THE WEATHER. ALL FLEX CONDUITS CONNECTED TO SUCH EQUIPMENT SHALL BE LIQUIDTIGHT. 15. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES AS REQUIRED FOR OTHER CLASSIFIED AREAS. U.O.N. 16. LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. AS PER NEC 410.10(D). 17. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. NEC 406.12; FBC RE4002.14 18 VERIFY IN THE FIELD LOCATION OF TELEPHONE RISER BEFORE ANY COMMENCEMENT OF WORK. 19 ALL LIGHTS ARE TO BE ON LUTRON DIMMABLE SWITCHES. 20 ALL RECEPTACLES ARE TO BE IN THE BASEBOARD AS SHOWN ON THE CONSTRUCTION DETAILS DWGS. 21 ALL STRIP WALL LIGHTS AT KITCHEN ARE UNDERCOUNTER LOW VOLTAGE LED LIGHTS. 22 CONTRACTOR TO WORK WITH INTERIOR DESIGNER ON DETAIL ON DETAIL FOR COVE / ROPE SOFFIT LIGHTING. 23 ALL BATHROOMS AND KITCHEN / POWDER ROOM CIRCUITS ARE TO BE DIRECT TO PANEL. 24 ALL ELECTRICAL IN THE AREAS OF RENOVATION WILL BE BROUGHT UP TO CURRENT CODE. THIS INCLUDES KITCHEN COUNTERTOP RECEPTACLES, SMOKE ALARMS ETC. THESE ELECTRICAL UPGRADES ARE SHOWN ON THE SUBMITTED PLANS. THE LOCATION OF THE EXISTING ELECTRICAL PANEL AND SERVICE SIZE IS SHOWN ON THE SUBMITTED DRAWINGS. 25 REMOVED 26 CONTRACTOR/INTERIOR DESIGNER/OWNER TO ENSURE AT LEAST 75% OF ALL PERMANENTLY INSTALLED FIXTURES HAVE HIGH EFFICIENCY BULBS PER 2014 FBC ENERGY CONSERVATION SECTION. ELECTRICAL NOTES SPECIAL NOTES: 1. CONTRACTOR SHALL PREPARED PANEL SCHEDULE AND INDICATE LIGHTNING AND POWER CIRCUIT LABELS/NUMBERS ON FLOOR PLAN WITH THE AS-BUILT DRAWINGS PRIOR TO FINAL INSPECTION. 2. CONTRACTOR SHALL COMPLY WITH FBC (C408.2.5.1). PROVIDE OWNER WITH A RECORD SET DRAWING OF COMPLETE INSTALLATION DRAWINGS. 3. CONTRACTOR SHALL COMPLY WITH FBC (C408.2.5.2). PROVIDE OWNER WITH OPERATIONAL MANUALS AND MAINTENANCE MANUALS. 4. CONTRACTOR/INTERIOR DESIGNER/OWNER TO ENSURE AT LEAST 75% OF ALL PERMANENTLY INSTALLED FIXTURES HAVE HIGH EFFICIENCY BULBS PER 2014 FBC ENERGY CONSERVATION SECTION. SHEET NUMBER REVISIONS This drawing is property of GMK, PALM BEACH, FLORIDA. Any use of this drawing or the design information hereon without written authorization of GMK is strictly prohibited. c 2021 GMK PALM BEACH, FLORIDA GMK PLANNING - ZONING - DESIGN G M KAGAN FAIA 205 WORTH AVENUE 201-111 PALM BEACH FL 33480 CELL: 203 988 1838 GMK@GMKPZD.COM SOSNOWSKI RESIDENCE Project Location: 3902 DUNESIDE DRIVE FT PIERCE, FL 34949 CONSULTANTS Project #: 2002 Architect: GERALD M. KAGAN DATE : 08-25-2021 SHEET NAME: SCALE: AS NOTED PERMIT SET INTERNATIONAL CONSULTING ENGINEERS & DESIGN, LLC 4310 WEST BROWARD BLVD. PLANTATION, FL 33317 T 561.707.6795 F 954.797.2847 CONTACT: JOE SPASOVSKI, P.E. UNISONSTRUCTURALDESIGN 7522 WILES RD, SUITE B204 CORAL SPRINGS, FL 33067 PHONE: (954) 323-3746 MOBIL: (305) 298-0467 EMAIL: UNISONSTRUCTURALDESIGN@GMAIL.COM WEB: UNISONSTRUCTURALDESIGN.COM DATE : 10-06-2021 REFLECTED CEILING AND ELECTRICAL PLAN REFLECTED CEILING & ELECTRICAL PLAN SCALE: 1/4" = 1' A1.2 N SW E REFLECTED CEILING PLAN NOTES 1.ARCHITECTURAL LIGHTING PLAN SUPERCEDES ELECTRICAL PLAN FOR LOCATIONS AND FIXTURE TYPE IF NOTED. COORDINATE WITH ELECTRICAL PLAN AND NOTIFY ARCHITECT IF THERE ARE ANY DISCREPANCIES PRIOR TO BID AND PURCHASING. 2.ALL ELECTRICAL FIXTURES TO BE PURCHASED AND SUPPLIED BY OWNER. INSTALLED BY GENERAL CONTRACTOR. 3.G.C. TO PROVIDE BLOCKING AS REQUIRED TO SECURE ALL CEILING MOUNTED FIXTURES AND DEVICES, TYP. 4.OWNER/ARCHITECT TO REVIEW ALL LIGHTING FIXTURE AND DEVICE LOCATIONS IN FIELD PRIOR TO INSTALLATION. 5. ALL CEILING HEIGHT ARE FROM FINISH FLOOR U.O.N. CEILING FINISHES: "A" - 5/8" DENSARMOR PLUS TYPE "X" CEILING; PAINTED. " B" - 5/8" DENSARMOR PLUS TYPE "X" TRAY CEILING; PAINTED. " C" - 3/4" TONGUE AND GROVE CEILING WITH VAPOR BARRIER ON 5/8" EXTERIOR PLYWOOD, TEAK FINISH. " D" - 3/4" SMOOTH STUCCO, 3-COAT, WITH WATERPROOFING EQUAL TO THEROSEAL" MASTERSEAL 583" OR APPROVED EQUAL, PAINTED. LATCH CASING BEAD CASING BEAD PIVOT HINGE 214"1" RECESS ACCESS OPENING ACOUSTIC INSULATION 1 4" DIA. THREADED PENCIL - ROD HANGERS BLACK-IRON CHANNEL FRAMING @ 4'-0" O.C. MAX 7 8" METAL FURRING HAT CHANNELS @ 16" O.C. (1) LAYER 58" G.W.B.V.I.F.TYPICAL DROP CEILING DETAIL3SCALE: 1 1/2" = 1'-0" TYPICAL RECESSED DRYWALL ATTIC ACCESS DOOR2SCALE: 1/2" = 1'-0" 1 08/25/21 CLIENT CHANGES 2 10/05/21 BDC COMMENTS 2 3 10/21/21 BDC COMMENTS 3